2553423 | 78394 | None | LS1 | Lynx ACSR conductor with 1.5% sag | Km | 192000.0 | 192000.0 | 38.64 | False | None | None | False | None | False | 7418880.0 | 0 |
2553424 | 78394 | None | LS2 | 7/3.15mm Ground wire with 1.5% sag | Km | 88000.0 | 88000.0 | 12.88 | False | None | None | False | None | False | 1133440.0 | 0 |
2553425 | 78394 | None | LS3 | 110kV, 90kN Single Tension type composite Polymer long rod Insulator with sectional length 1160mm fittings suitable for 110kV Lynx ACSR, Clamps, Arcing Horns and Hardwares (Set) | Set | 5282.0 | 5282.0 | 66.0 | False | None | None | False | None | False | 348612.0 | 0 |
2553426 | 78394 | None | LS4 | 110kV, 90kN Double Tension type composite Polymer long rod Insulator with sectional length 1160mm fittings suitable for 110kV Lynx ACSR, Clamps, Arcing Horns and Hardwares (Set) | Set | 11953.0 | 11953.0 | 12.0 | False | None | None | False | None | False | 143436.0 | 0 |
2553427 | 78394 | None | LS5 | Single Suspension String fittings using composite Polymer long rod Insulator with sectional length 1160mm fittings suitable for 110kV Lynx ACSR, Clamps, Arcing Horns and Hardwares (Set) | Set | 5387.0 | 5387.0 | 93.0 | False | None | None | False | None | False | 500991.0 | 0 |
2553428 | 78394 | None | LS6 | Double Suspension String fittings using composite Polymer long rod Insulator with sectional length 1160mm fittings suitable for 110kV Lynx ACSR, Clamps, Arcing Horns and Hardwares (Set) | Set | 10590.0 | 10590.0 | 12.0 | False | None | None | False | None | False | 127080.0 | 0 |
2553429 | 78394 | None | LS7 | Accessories for ACSR Lynx conductor-Mid Span Compression Joint for LYNX | Nos | 668.0 | 668.0 | 40.0 | False | None | None | False | None | False | 26720.0 | 0 |
2553430 | 78394 | None | LS8 | Accessories for ACSR Lynx conductor-Repair Sleeves suitable for LYNX | Nos | 592.0 | 592.0 | 20.0 | False | None | None | False | None | False | 11840.0 | 0 |
2553431 | 78394 | None | LS9 | Accessories for ACSR Lynx conductor-Preformed armour rod | Nos | 1263.0 | 1263.0 | 105.0 | False | None | None | False | None | False | 132615.0 | 0 |
2553432 | 78394 | None | LS10 | Accessories for ACSR Lynx conductor-Vibration dampers | Nos | 1014.0 | 1014.0 | 288.0 | False | None | None | False | None | False | 292032.0 | 0 |
2553433 | 78394 | None | LS11 | Accessories for ACSR Lynx conductor-P.G Clamps for Lynx Conductor | Nos | 776.0 | 776.0 | 78.0 | False | None | None | False | None | False | 60528.0 | 0 |
2553434 | 78394 | None | LS12 | Hardware & Accessories for Ground Wire-Mid Span Compression Joint for Ground wire | Nos | 457.0 | 457.0 | 12.0 | False | None | None | False | None | False | 5484.0 | 0 |
2553435 | 78394 | None | LS13 | Hardware & Accessories for Ground Wire-Repair Sleeves suitable for Ground wire | Nos | 309.0 | 309.0 | 6.0 | False | None | None | False | None | False | 1854.0 | 0 |
2553436 | 78394 | None | LS14 | Hardware & Accessories for Ground Wire-Suspension clamps | Nos | 1301.0 | 1301.0 | 35.0 | False | None | None | False | None | False | 45535.0 | 0 |
2553437 | 78394 | None | LS15 | Hardware & Accessories for Ground Wire-Tension clamps | Nos | 1234.0 | 1234.0 | 26.0 | False | None | None | False | None | False | 32084.0 | 0 |
2553438 | 78394 | None | LS16 | Hardware & Accessories for Ground Wire-P.G Clamps for Ground Wire | Nos | 403.0 | 403.0 | 26.0 | False | None | None | False | None | False | 10478.0 | 0 |
2553439 | 78394 | None | LE1 | Check survey by using their own equipments for 110kV plain terrain | Km | 2904.0 | 2904.0 | 12.69 | False | None | None | False | None | False | 36851.76 | 0 |
2553440 | 78394 | None | LE2 | Lynx ACSR conductor with 1.5 percentage sag | Km | 8000.0 | 8000.0 | 38.64 | False | None | None | False | None | False | 309120.0 | 0 |
2553441 | 78394 | None | LE3 | 7/3.15mm Ground wire with 1.5 percentage sag | Km | 11000.0 | 11000.0 | 12.88 | False | None | None | False | None | False | 141680.0 | 0 |
2553442 | 78394 | None | LE4 | Area specific loading on above Basic rate items at 5 percentage | LS | 538963.0 | 538963.0 | 1.0 | False | None | None | False | None | False | 538963.0 | 0 |
2553443 | 78394 | None | LE5 | Applicable GST on above total at 18 percentage | LS | 2037280.0 | 2037280.0 | 1.0 | False | None | None | False | None | False | 2037280.0 | 0 |
2553444 | 78394 | None | TBS1 | Circuit Breaker -
SF6 Gas circuit breaker with Semi-Pneumatic / Pneumatic operated / Spring type operating mechanism, including mounting arrangements, rigid bi-metallic terminal connector complete suitable for Drake ACSR conductor and mounting structures.
a) 110kV, 1250A, 40KA Class | Nos | 703010.0 | 703010.0 | 1.0 | False | None | None | False | None | False | 703010.0 | 0 |
2553445 | 78394 | None | TBS2 | Isolators - Isolators including marshalling box and suitable terminal connectors, as required as per technical specification with solid core cylindrical post insulators-
A) 110KV, 1250A, 40KA Class Double Break Manually operated isolator With terminal connectors suitable for Drake ACSR-Upright mounting type with earth switch with live point height 4600mm | Set | 381150.0 | 381150.0 | 1.0 | False | None | None | False | None | False | 381150.0 | 0 |
2553446 | 78394 | None | TBS3 | Isolators - Isolators including marshalling box and suitable terminal connectors, as required as per technical specification with solid core cylindrical post insulators-
A) 110KV, 1250A, 40KA Class Double Break Manually operated isolator With terminal connectors suitable for Drake ACSR-Upright mounting type without earth switch HPH 4600mm | Set | 321860.0 | 321860.0 | 1.0 | False | None | None | False | None | False | 321860.0 | 0 |
2553447 | 78394 | None | TBS4 | Current Transformer -Current Transformer including Marshalling box, Single phase, oil filled outdoor type with rigid bimetallic terminal connectors suitable for Drake ACSR.110 KV Class, 40KA, CT of ratio 400-200/1-1-1A for 110kV Line .
For metering- Accuracy 0.2, Burden 10VA
For back up protection - Accuracy 5P20, Burden 30VA
For differential/ distance protection- PS class. | Nos | 135520.0 | 135520.0 | 3.0 | False | None | None | False | None | False | 406560.0 | 0 |
2553448 | 78394 | None | TBS5 | Lightning Arrestor -
Surge arrestors (Polymeric) Metal Oxide Gap less type as per technical specification with suitable rigid bi-metallic terminal connectors suitable for Drake ACSR-96 KV, 10 KA, Class - 2 ( For Lines) | Nos. | 41140.0 | 41140.0 | 3.0 | False | None | None | False | None | False | 123420.0 | 0 |
2553449 | 78394 | None | TBS6 | Control Panels -
Simplex Type Control and Relay Panel complete as per specifications (Control Voltage 110 V DC)-For 110kV Transmission line. | Nos. | 456170.0 | 456170.0 | 1.0 | False | None | None | False | None | False | 456170.0 | 0 |
2553450 | 78394 | None | TBS7 | Station Structures-
A) 110kV Side station structure fabricated out of galvanized mild steel including Bolts and Nuts Station towers (verticals 1T1) - (0.956 Per MT) | Nos. | 129557.12 | 129557.12 | 1.0 | False | None | None | False | None | False | 129557.12 | 0 |
2553451 | 78394 | None | TBS8 | Station Structures-
A) 110kV Side station structure fabricated out of galvanized mild steel including Bolts and Nuts Station structure beams (1B1) (0.504 Per MT) | No | 135520.0 | 135520.0 | 0.504 | False | None | None | False | None | False | 68302.08 | 0 |
2553452 | 78394 | None | TBS9 | Station Structures-
A) 110kV Side station structure fabricated out of galvanized mild steel including Bolts and Nuts -110KV Isolators Live Point Height 4600mm - (0.741 Per MT) | Nos. | 135520.0 | 135520.0 | 1.482 | False | None | None | False | None | False | 200840.64 | 0 |
2553453 | 78394 | None | TBS10 | Station Structures-
A) 110kV Side station structure fabricated out of galvanized mild steel including Bolts and Nuts -110KV Current transformers & 11kV NCTs | Nos. | 135520.0 | 135520.0 | 0.456 | False | None | None | False | None | False | 61797.12 | 0 |
2553454 | 78394 | None | TBS11 | 110KV Lightening arrestors - (0.111 Per MT) | Nos. | 135520.0 | 135520.0 | 0.333 | False | None | None | False | None | False | 45128.16 | 0 |
2553455 | 78394 | None | TBS12 | 110KV Pedestal insulator | Nos. | 135520.0 | 135520.0 | 0.423 | False | None | None | False | None | False | 57324.96 | 0 |
2553456 | 78394 | None | TBS13 | BUS BAR FORMATION-Drake ACSR | Mtr | 387.0 | 387.0 | 250.0 | False | None | None | False | None | False | 96750.0 | 0 |
2553457 | 78394 | None | TBS14 | Insulators -110 KV Class, 1 Unit per stack | Nos | 12055.0 | 12055.0 | 3.0 | False | None | None | False | None | False | 36165.0 | 0 |
2553458 | 78394 | None | TBS15 | Hardwares-C-Type Wedge Connector for Lynx - Drake( for 110kV Line side) - Fired Wedge Connector Type | Nos | 1921.0 | 1921.0 | 6.0 | False | None | None | False | None | False | 11526.0 | 0 |
2553459 | 78394 | None | TBS16 | Hardwares-Clamp suitable for Drake - Drake( for 110kV Bus) - Fired Wedge Connector Type | Nos | 2305.0 | 2305.0 | 6.0 | False | None | None | False | None | False | 13830.0 | 0 |
2553460 | 78394 | None | TBS17 | Hardwares-Post insulator clamp suitable for Single Drake ACSR and 110kV Solid Core Insulator. | Nos | 1010.0 | 1010.0 | 3.0 | False | None | None | False | None | False | 3030.0 | 0 |
2553461 | 78394 | None | TBS18 | 19 Core 2.5 Sq.mm. Copper Control Cables | Mtr | 525.0 | 525.0 | 200.0 | False | None | None | False | None | False | 105000.0 | 0 |
2553462 | 78394 | None | TBS19 | 4 Core 2.5 Sq.mm. Copper Control Cables | Mtr | 142.0 | 142.0 | 300.0 | False | None | None | False | None | False | 42600.0 | 0 |
2553463 | 78394 | None | TBS20 | 4 Core 6 Sq.mm. Copper Control Cables | Mtr | 247.0 | 247.0 | 600.0 | False | None | None | False | None | False | 148200.0 | 0 |
2553464 | 78394 | None | TBS21 | 2 Core 6 Sq.mm. Copper Control Cables | Mtr | 154.0 | 154.0 | 200.0 | False | None | None | False | None | False | 30800.0 | 0 |
2553465 | 78394 | None | TBS22 | Earth mat formation-Grounding of equipments by providing cast iron pipe of 100mm ID 13mm thickness, 2.75mtrs long with 2 part clamp out of G.I.Flat 50x6 mm continuously welded around the pipe using cast iron welding electrodes as per drawing including the cost of excavation, providing & laying homogeneous mixture of charcoal lumps, salt & sand all round the pipe as per specification. | Set | 12792.0 | 12792.0 | 3.0 | False | None | None | False | None | False | 38376.0 | 0 |
2553466 | 78394 | None | TBE1 | Circuit Breaker-
SF6 Gas circuit breaker with Semi-Pneumatic / Pneumatic operated / Spring type operating mechanism, including mounting arrangements, rigid bi-metallic terminal connector complete suitable for Drake ACSR conductor and mounting structures.
110kV, 1250A, 40KA Class | Nos | 14692.0 | 14692.0 | 1.0 | False | None | None | False | None | False | 14692.0 | 0 |
2553467 | 78394 | None | TBE2 | Isolators including marshalling box and suitable terminal connectors, as required as per technical specification with solid core cylindrical post insulators-
A) 110KV, 1250A, 40KA Class Double Break Manually operated isolator With terminal connectors suitable for Drake ACSRUpright mounting type with earth switch with live point height 4600mm | Set | 8701.0 | 8701.0 | 1.0 | False | None | None | False | None | False | 8701.0 | 0 |
2553468 | 78394 | None | TBE3 | Isolators including marshalling box and suitable terminal connectors, as required as per technical specification with solid core cylindrical post insulators-
A) 110KV, 1250A, 40KA Class Double Break Manually operated isolator With terminal connectors suitable for Drake ACSRUpright mounting type without earth switch HPH 4600mm | Nos | 8701.0 | 8701.0 | 1.0 | False | None | None | False | None | False | 8701.0 | 0 |
2553469 | 78394 | None | TBE4 | Current Transformer-Current Transformer including Marshalling box, Single phase, oil filled outdoor type with rigid bimetallic terminal connectors suitable for Drake ACSR-110 KV Class, 40KA, CT of ratio 400-200/1-1-1A for 110kV Line .
For metering-Accuracy 0.2, Burden 10VA
For back up protection - Accuracy 5P20, Burden 30VA
For differential/ distance protection: PS class. | Nos | 7817.0 | 7817.0 | 3.0 | False | None | None | False | None | False | 23451.0 | 0 |
2553470 | 78394 | None | TBE5 | Lightning Arrestor-
Surge arrestors (Polymeric) Metal Oxide Gap less type as per technical specification with suitable rigid bi-metallic terminal connectors suitable for Drake ACSR.-96 KV, 10 KA, Class - 2 ( For Lines) | Nos. | 1332.0 | 1332.0 | 3.0 | False | None | None | False | None | False | 3996.0 | 0 |
2553471 | 78394 | None | TBE6 | Control Panels-
Simplex Type Control and Relay Panel complete as per specifications (Control Voltage 110 V DC).-For 110kV Transmission line. | Nos. | 13571.0 | 13571.0 | 1.0 | False | None | None | False | None | False | 13571.0 | 0 |
2553472 | 78394 | None | TBE7 | Station Structures-
A) 110kV Side station structure fabricated out of galvanized mild steel including Bolts and Nuts-Station towers. | Nos | 5723.0 | 5723.0 | 0.956 | False | None | None | False | None | False | 5471.188 | 0 |
2553473 | 78394 | None | TBE8 | Station Structures-
A) 110kV Side station structure fabricated out of galvanized mild steel including Bolts and Nuts-Station structure beams (1B1) (0.504 Per MT) | Nos. | 5723.0 | 5723.0 | 0.504 | False | None | None | False | None | False | 2884.392 | 0 |
2553474 | 78394 | None | TBE9 | GI Mounting structure including Bolts AND Nuts (Lattice type) (For 110KV Sub-Station) - 110KV Isolators Live Point Height 4600mm | MT | 5723.0 | 5723.0 | 1.482 | False | None | None | False | None | False | 8481.486 | 0 |
2553475 | 78394 | None | TBE10 | GI Mounting structure including Bolts AND Nuts (Lattice type) (For 110KV Sub-Station) - 110KV Current transformers AND 11kV NCTs - (0.152 Per MT) | Nos. | 5723.0 | 5723.0 | 0.456 | False | None | None | False | None | False | 2609.688 | 0 |
2553476 | 78394 | None | TBE11 | GI Mounting structure including Bolts & Nuts (Lattice type) (For 110KV Sub-Station) - 110KV Lightening arrestors - (0.111 Per MT) | Nos | 5723.0 | 5723.0 | 0.333 | False | None | None | False | None | False | 1905.759 | 0 |
2553477 | 78394 | None | TBE12 | GI Mounting structure including Bolts & Nuts (Lattice type) (For 110KV Sub-Station) - 110KV Pedestal insulator - (0.141 Per MT) | Nos. | 5723.0 | 5723.0 | 0.423 | False | None | None | False | None | False | 2420.829 | 0 |
2553478 | 78394 | None | TBE13 | BUS BAR FORMATION-Drake ACSR | Mtr | 7134.0 | 7134.0 | 250.0 | False | None | None | False | None | False | 1783500.0 | 0 |
2553479 | 78394 | None | TBE14 | Formation of main/ cross BUS with single Drake Conductor for 110kV | Nos | 12087.0 | 12087.0 | 1.0 | False | None | None | False | None | False | 12087.0 | 0 |
2553480 | 78394 | None | TBE15 | Post insulators - Cylindrical solid core as per IS5350, Part II and III 110 KV Class, 1 Unit per stack | Nos | 444.0 | 444.0 | 3.0 | False | None | None | False | None | False | 1332.0 | 0 |
2553481 | 78394 | None | TBE16 | 1.1kV PVC insulated-19 Core 2.5 Sq.mm. Copper Control Cables | Mtr | 15.0 | 15.0 | 200.0 | False | None | None | False | None | False | 3000.0 | 0 |
2553482 | 78394 | None | TBE17 | 1.1kV PVC insulated-4 Core 2.5 Sq.mm. Copper Control Cables | Mtr | 15.0 | 15.0 | 300.0 | False | None | None | False | None | False | 4500.0 | 0 |
2553483 | 78394 | None | TBE18 | 1.1kV PVC insulated-4 Core 6 Sq.mm. Copper Control Cables | Mtr | 15.0 | 15.0 | 600.0 | False | None | None | False | None | False | 9000.0 | 0 |
2553484 | 78394 | None | TBE19 | 1.1kV PVC insulated-2 Core 6 Sq.mm. Copper Control Cables | Mtr | 15.0 | 15.0 | 200.0 | False | None | None | False | None | False | 3000.0 | 0 |
2553485 | 78394 | None | TBE20 | Supplying and Grounding of Equipment with G.I.Flat 50x6mm and connecting Equipment to the earth mat/ground pit. Each point of earthing with all formation works like bending, twisting, drilling of holes and connecting by welding (inclusive of T&P and consumables) to the earthmat/Groundpit/point of earth connection. | Mtr | 335.0 | 335.0 | 300.0 | False | None | None | False | None | False | 100500.0 | 0 |
2553486 | 78394 | None | TBE21 | Grounding of equipments by providing cast iron pipe of 100mm ID 13mm thickness, 2.75mtrs long with 2 part clamp out of G.I.Flat 50x6 mm continuously welded around the pipe using cast iron welding electrodes as per drawing including the cost of excavation, providing & laying homogeneous mixture of charcoal lumps, salt & sand all round the pipe as per specification. | Nos | 3491.0 | 3491.0 | 3.0 | False | None | None | False | None | False | 10473.0 | 0 |
2553487 | 78394 | None | TBE22 | Supplying and fixing of RCC collar of size 450mm dia, 450mm height 1.5 inch to 2 inch Hume pipe collors for earth pits | Nos | 1499.0 | 1499.0 | 3.0 | False | None | None | False | None | False | 4497.0 | 0 |
2553488 | 78394 | None | T01 | Circuit Breaker-
SF6 Gas circuit breaker with Semi-Pneumatic / Pneumatic operated / Spring type operating mechanism, including mounting arrangements, rigid bi-metallic terminal connector complete suitable for Drake ACSR conductor and mounting structures.
110kV, 1250A, 40KA Class | Nos | 42300.0 | 42300.0 | 1.0 | False | None | None | False | None | False | 42300.0 | 0 |
2553489 | 78394 | None | T02 | Isolators including marshalling box and suitable terminal connectors, as required as per technical specification with solid core cylindrical post insulators-
A) 110KV, 1250A, 40KA Class Double Break Manually operated isolator With terminal connectors suitable for Drake ACSRUpright mounting type with earth switch with live point height 4600mm | Set | 1301.0 | 1301.0 | 1.0 | False | None | None | False | None | False | 1301.0 | 0 |
2553490 | 78394 | None | T03 | Isolators including marshalling box and suitable terminal connectors, as required as per technical specification with solid core cylindrical post insulators-
A) 110KV, 1250A, 40KA Class Double Break Manually operated isolator With terminal connectors suitable for Drake ACSRUpright mounting type without earth switch HPH 4600mm | Set | 1301.0 | 1301.0 | 1.0 | False | None | None | False | None | False | 1301.0 | 0 |
2553491 | 78394 | None | T04 | Current Transformer-Current Transformer including Marshalling box, Single phase, oil filled outdoor type with rigid bimetallic terminal connectors suitable for Drake ACSR-110 KV Class, 40KA, CT of ratio 400-200/1-1-1A for 110kV Line .
For metering-Accuracy 0.2, Burden 10VA
For back up protection - Accuracy 5P20, Burden 30VA
For differential/ distance protection: PS class. | Nos | 14101.0 | 14101.0 | 3.0 | False | None | None | False | None | False | 42303.0 | 0 |
2553492 | 78394 | None | T05 | Control Panels-
Simplex Type Control and Relay Panel complete as per specifications (Control Voltage 110 V DC).-For 110kV Transmission line. | Nos. | 42973.0 | 42973.0 | 1.0 | False | None | None | False | None | False | 42973.0 | 0 |
2553493 | 78394 | None | TBC1 | Foundations- Design, Engineering, supply of all labour, material and construction of RCC (M20 Grade) footings and pedestals of any section/size including the cost of excavation in all types of soil/rock, back filling with available approved earth or borrowed/new earth, disposal of surplus earth/rock to the places directed, concrete (M20 Grade and Lean concrete110 KV Station structure fabricated out of galvanised iron, column type 1T1 with peak | Nos. | 85969.0 | 85969.0 | 1.0 | False | None | None | False | None | False | 85969.0 | 0 |
2553494 | 78394 | None | TBC2 | 110 kV Isolators | Nos. | 31604.0 | 31604.0 | 2.0 | False | None | None | False | None | False | 63208.0 | 0 |
2553495 | 78394 | None | TBC3 | 110 kV Current Transformer | Nos. | 16307.0 | 16307.0 | 3.0 | False | None | None | False | None | False | 48921.0 | 0 |
2553496 | 78394 | None | TBC4 | 110 kV Lightning Arrestors | Nos. | 9800.0 | 9800.0 | 3.0 | False | None | None | False | None | False | 29400.0 | 0 |
2553497 | 78394 | None | TBC5 | 110KV Pedastal insulator (for bus) | Nos. | 8003.0 | 8003.0 | 3.0 | False | None | None | False | None | False | 24009.0 | 0 |
2553498 | 78394 | None | TBC6 | Cable Trenches-SSY - Type 3 / Type E (with 2 Nos. 150mm dia RCC Hume pipes including required size of PVC/G.I. Pipe for taking cable from equipments to hume pipes etc.) | m | 1404.0 | 1404.0 | 10.0 | False | None | None | False | None | False | 14040.0 | 0 |
2553499 | 78394 | None | TBC7 | Cable Trenches-SSY-Type 4 / Type F
(with 1 No. 150mm dia RCC Hume pipe including required size of PVC/G.I. Pipe for taking cable from equipments to hume pipes etc.) | m | 725.0 | 725.0 | 20.0 | False | None | None | False | None | False | 14500.0 | 0 |
2553500 | 78394 | None | TBC8 | Construction of Inspection Chambers 45 x 45 cms with covers (interior clear dimensions) and of suitable depth with table moulded brick in CM 1-6, 23 Cms thick on a bed of 15.24 cms thick CC 1-3-6and CM 1-4 plastered complete including providing and fixing 45 x 45 cms CI frame and cover in CC 1-2-4,7.5 cms thick and other details as per specification for manhole upto 0.6 m depth (including the cost of CI frame and cover. | Nos. | 6198.0 | 6198.0 | 4.0 | False | None | None | False | None | False | 24792.0 | 0 |
2553501 | 78394 | None | TBC9 | JELLY SPREADING-
Supplying all labour, materials, equipments and Providing and laying 100mm thick granite using 20mm size jelly including the cost of jelly, sundries and etc | Mtr | 177.3 | 177.3 | 350.0 | False | None | None | False | None | False | 62055.0 | 0 |
2553502 | 78394 | None | TBC10 | Circuit Breaker Foundation-SF6 CIRCUIT BREAKERS , 110kV SF6 Circuit Breakers | Nos | 79160.0 | 79160.0 | 1.0 | False | None | None | False | None | False | 79160.0 | 0 |
2553503 | 78394 | None | TBC11 | Area specific loading on above Basic rate items at 5 percentage | LS | 304320.0 | 304320.0 | 1.0 | False | None | None | False | None | False | 304320.0 | 0 |
2553504 | 78394 | None | TBC12 | Applicable GST on above total at 18 percentage | LS | 1150330.0 | 1150330.0 | 1.0 | False | None | None | False | None | False | 1150330.0 | 0 |
2553505 | 78394 | None | FC01 | Forest Clearance, Tree Cut compensation etc | LS | 1271383.0 | 1271383.0 | 1.0 | False | None | None | False | None | False | 1271383.0 | 0 |