createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1707733370830
version5
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeONE_COVER
evaluationTypeTextOne Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee1020.00
emd96000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose19-02-2024 17:29:35
tenderQueryClose16-02-2024 10:30:22
technicalBidOpenNone
publishedDate12-02-2024 15:59:17
publishedByPostDMA_EE2_CC_MYS
publishedByUserKPE16495 - MAHESH M S
bidValidityPeriod90
noOfCalls2
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnTrue
percentageRateTypeTextNone
contactPersonLOHITH
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9980819479
tenderSupplierListNone
tenderSchedule
createdTs1707733370833
version13
createdDateNone
modifiedDateNone
tenderNumberDMA/2023-24/OW/WORK_INDENT13400/CALL-2
titleCONSTRUCTION OF INDIRA CANTEEN IN VACANT PLACE INSIDE MAHARANI COLLEGE AT PADUVARAHALLI UNDER ZONE 4 MYSURU
descriptionCONSTRUCTION OF INDIRA CANTEEN IN VACANT PLACE INSIDE MAHARANI COLLEGE AT PADUVARAHALLI UNDER ZONE 4 MYSURU
categoryWORKS
categoryTextWorks
ecv4041237.64
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2163
locationNameDMA City Corporation Mysuru
provisionalAmount4800000.0
groupOverheadTotalNone
fileNumberEE/W/MCC/2023-24/TN-33/35
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17077333710001NoneNoneOther WorksCONSTRUCTION OF INDIRA CANTEEN IN VACANT PLACE INSIDE MAHARANI COLLEGE AT PADUVARAHALLI UNDER ZONE 4 MYSURU4041237.64
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
255434878442None1.4.1 v1Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKCum254.1254.1262.3FalseNoneNoneFalseNoneFalse66650.430
255434978442None2.1.3 v1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKCum6288.456288.45110.09FalseNoneNoneFalseNoneFalse692295.46050
255435078442None5.4 v2Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKCum6708.456708.4546.44FalseNoneNoneFalseNoneFalse311540.4180
255435178442None5.2 v2Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKCum6948.96948.925.13FalseNoneNoneFalseNoneFalse174625.8570
255435278442None8.19.1 v2Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lin ing, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKSqm267.75267.7565.2FalseNoneNoneFalseNoneFalse17457.30
255435378442None1.9 v1Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKCum279.3279.349.14FalseNoneNoneFalseNoneFalse13724.8020
255435478442None4.2.1 v4Providing, diluting and injecting chemical emulsion for Post-constructional antitermite treatment with Chlorpyriphos/ Lindane E.C. 20% with 1% concentration 4.2.1 Along external wall where the apron is not provided using chemical emulsion @ 7.5 l/m2 of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete: ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKSqm117.6117.6302.4FalseNoneNoneFalseNoneFalse35562.240
255435578442None2.3.1 v1Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. 8% formwork ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKCum7170.287170.284.5FalseNoneNoneFalseNoneFalse32266.260
255435678442None2.3.2 v1Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. 50% formwork ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKCum10206.010206.031.28FalseNoneNoneFalseNoneFalse319243.680
255435778442None2.11a v1Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKTonne93929.8593929.854.05FalseNoneNoneFalseNoneFalse380415.89250
255435878442None7.3 v5Providing and fixing MS inspection door of size 60 cms x 60 cms, including MS frame made of 50x50x6mm angle, shutters made of 3mm thick MS sheets, with hinges, locking arrangements at top etc. including painting with anticorrosive approved paint etc. complete including all lead and lifts etc. ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKEach2247.02247.01.0FalseNoneNoneFalseNoneFalse2247.00
255435978442None8.2.2 v2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKSqm292.95292.9540.8FalseNoneNoneFalseNoneFalse11952.360
255436078442None15.6 v2Food Graded Water Proofing Membrane Providing and laying water proofing treatment to the Water tanks & Liq uid Retaining structures with two component acrylic polymer modified cementitious waterproofing membrane with minimum elongation of 50% applied @ 1.5 kg/m2 for internal side waterproofing in two layers with waiting period of 4-6 hrs per layer and food grade epoxy coating in two coats certified by CFTRI Mysuru, including surface preparation completely as per specification. ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKSqm532.35532.3540.8FalseNoneNoneFalseNoneFalse21719.880
255436178442None11.34b v2Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKKg192.15192.154791.15FalseNoneNoneFalseNoneFalse920619.47250
255436278442None11.25.2 v2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in Charge. ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKKg142.8142.81122.02FalseNoneNoneFalseNoneFalse160224.4560
255436378442None8.41 v2Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKSqm175.35175.35160.78FalseNoneNoneFalseNoneFalse28192.7730
255436478442None9.25 v2Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKSqm840.0840.0330.75FalseNoneNoneFalseNoneFalse277830.00
255436578442None8.2 b v3Construction of cement concrete kerb with channel with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M10 grade foundation 150 mm thick, kerb channel 300 mm wide, 50 mm thick in PCC M20 grade, sloped towards the kerb, kerb stone with channel laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 409. b. PCC M20 grade for kerb Cast in Situ ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKm389.55389.55107.1FalseNoneNoneFalseNoneFalse41720.8050
255436678442None16.11 v5Constructing brick masonry chamber of internal dimension 450x300mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.. ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKEach3726.453726.452.0FalseNoneNoneFalseNoneFalse7452.90
255436778442None13.12 v2Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKEach666.75666.7510.0FalseNoneNoneFalseNoneFalse6667.50
255436878442None13.32.3 v2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia pipes ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKm469.35469.3565.0FalseNoneNoneFalseNoneFalse30507.750
255436978442None13.32.2 v2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipes ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKm397.95397.9565.0FalseNoneNoneFalseNoneFalse25866.750
255437078442None14.7.1 v2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKEach3236.13236.12.0FalseNoneNoneFalseNoneFalse6472.20
255437178442None2018-19 sr1 HP motor monoblock ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKEach9209.239209.231.0FalseNoneNoneFalseNoneFalse9209.230
255437278442None13.34 v2Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKLtr9.459.452000.0FalseNoneNoneFalseNoneFalse18900.00
255437378442None1.17.1 v1Earth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. All kinds of soils. Depth upto 1.50 m ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKCum275.1275.13.63FalseNoneNoneFalseNoneFalse998.6130
255437478442None16.60.1 v5Providing PVC-U INDIVIDUAL U.G.D House service connection (which shall be laid from inside the customer property ) which includes: a) Supply of PVC-U pipe (b) providing and fixing of 315 mm dia the PE Inspection chambres with lid consisting of inlet & outlet arrangements with base, riser of min. 0.42 m depth which includes earth work, fixing in CC-1:2:4 with appurtenances., complete. (c) civil works like Earthwork excavation for the pipeline trenches for laying of PVC-U pipes for the house connections in all types of soils , disintegrated rock,soft rock, hard rock, including cutting of any road using , crossing drains, compound, Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, c.c. wood work, steel work, including T & P and scaffolding wherever necessary sorting the dismantled material, disposal of unserviceable and stacking the serviceable material with all lifts and lead , restoring the damaged portions inside or outside the property premises, refilling the portions of trenches that are dug open including linking to existing sewer network with appurtenances. complete. 110 mm dia ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKEach8378.028378.021.0FalseNoneNoneFalseNoneFalse8378.020
255437578442None10.1.7 v5Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete for PVC pipes 110mm dia., 6 kg/sqcm & class 3 ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKm431.55431.5520.0FalseNoneNoneFalseNoneFalse8631.00
255437678442None16.15.1 v5Providing and constructing "WIRE CUT BRICK MACHINEHOLE CHAMBERS" using Portland/Pozzolana cement, conical in shape at top, with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15M alround the chamber. Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Providing and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Providing and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, de-watering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc. for 1.2mm dia: Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. , 1.0 M depth & SFRC cover & frame ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKEach30499.3530499.351.0FalseNoneNoneFalseNoneFalse30499.350
255437778442None1.1.2 v6Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25 mm dia 2 mm thick ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKm81.081.0100.0FalseNoneNoneFalseNoneFalse8100.00
255437878442None2.1.1 v6Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKPoint285.0285.06.0FalseNoneNoneFalseNoneFalse1710.00
255437978442None2.1.2 v6Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKPoint394.0394.06.0FalseNoneNoneFalseNoneFalse2364.00
255438078442None3.1.1 v6Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 3.1.1 6A 2 Way ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKEach128.0128.020.0FalseNoneNoneFalseNoneFalse2560.00
255438178442None2.3.3 v6Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:2010 2.5 mm2 ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKm42.042.0300.0FalseNoneNoneFalseNoneFalse12600.00
255438278442None3.6.3 v6Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Three Way socket ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKEach171.0171.020.0FalseNoneNoneFalseNoneFalse3420.00
255438378442None5.18.1 v6Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKEach415.0415.02.0FalseNoneNoneFalseNoneFalse830.00
255438478442None6.3.2 v6Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 56" Sweep (1400 mm) Regular model ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKEach3031.03031.03.0FalseNoneNoneFalseNoneFalse9093.00
255438578442None11.5.3 v6Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @50/60Hz & Power factor greater than0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKEach1324.01324.04.0FalseNoneNoneFalseNoneFalse5296.00
255438678442None11.5.2 v6Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @50/60Hz & Power factor greater than0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12W ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKEach885.0885.07.0FalseNoneNoneFalseNoneFalse6195.00
255438778442None32.03 v61.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm) ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKKm118004.0118004.00.06FalseNoneNoneFalseNoneFalse7080.240
255438878442None1.9.2 v6Supplying PVC flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely 25 mm ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKm22.022.060.0FalseNoneNoneFalseNoneFalse1320.00
255438978442None4.4.7 v6Fabricating, supplying and erection of ... ms long hot dip Galvanized Conical hot dip Pole with BSEN 10025 grade S355JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for ....... m Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom ..... mm , top ... mm with 3 mm thick, suitable base plate and 4Nos of.........long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc.,(excluding foundation) as per drawing appended. 9 m - Top 75 mm and Bottom 165 mm dia ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKEach20500.020500.04.0FalseNoneNoneFalseNoneFalse82000.00
255439078442None11.9.1 v6Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ....... W System Power consumption. LED Efficiencygreater than 1301m/w, nominal CRI greater than75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Floodlight 70W ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKEach6768.06768.08.0FalseNoneNoneFalseNoneFalse54144.00
255439178442None4.6.1 v6Supplying, and fixing of Hot dip Galvanized M.S.Bracket suitable for out door luminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete. Single Arm Bracket with 1000 mm Standard 40/50 mm dia ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKEach1700.01700.08.0FalseNoneNoneFalseNoneFalse13600.00
255439278442None13.6 v6Fixing charges of post top/ Gate/ Garden fitting /LED on the existing CI/ GI or any other pipe using required size of reducer, wiring using suitable wires. ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKEach198.0198.08.0FalseNoneNoneFalseNoneFalse1584.00
255439378442None2.5.8 v6Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 2C x 2.5 mm2 ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKm113.0113.0150.0FalseNoneNoneFalseNoneFalse16950.00
255439478442None12.60.1 v6Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm Using 4ft. Copper bonded rod with backfill compound ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKKit4528.04528.01.0FalseNoneNoneFalseNoneFalse4528.00
255439578442Nonequotation rateSolar PV module 160 Watt Monno Crystalline ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKEach6000.06000.08.0FalseNoneNoneFalseNoneFalse48000.00
255439678442Nonequotation rate12.8 V Life PO4 24Ah Battery ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKEach7800.07800.08.0FalseNoneNoneFalseNoneFalse62400.00
255439778442Nonequotation rateSolar Panel Mounting Structure ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKEach12000.012000.01.0FalseNoneNoneFalseNoneFalse12000.00
255439878442None5.42.2 v6Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 16 SWG ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKSq CM0.430.4325000.0FalseNoneNoneFalseNoneFalse10750.00
255439978442None5.55 vMPPT charge controller ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKEach5500.05500.01.0FalseNoneNoneFalseNoneFalse5500.00
255440078442None5.60 v6Supply, Installation & Commissioning of lighting control automation -Wireless PIR Motion Sensor Wireless PIR .Motion Sensor (Product no -) PIR sensors shall be deployed for on demand lighting / electric requirement- for example restroom operation with maximum load of 200 W, outdoor monitoring during night activating Light, Siren, etc ---- WITH ALL LEAD AND LIFT AND AS PER THE DIRECTION OF ENGINEER IN-CHARGE OF WORKEach7341.07341.01.0FalseNoneNoneFalseNoneFalse7341.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17077333710000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17077333710000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17077333710000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17077333710000NoneNoneELIGIBILITYMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)None
17077333710000NoneNoneELIGIBILITYSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)None
17077333710000NoneNoneELIGIBILITYTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNone
17077333710000NoneNoneELIGIBILITYTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNone
17077333710000NoneNoneELIGIBILITYTotal value of civl engineering works executed and payments received in the last five years (year-wise)None
17077333710000NoneNoneELIGIBILITYList of existing commitments and ongoing worksNone
17077333710000NoneNoneELIGIBILITYList of works for which tenders already submittedNone
17077333710000NoneNoneELIGIBILITYBanker Details for referenceNone
17077333710000NoneNoneELIGIBILITYConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNone
17077333710000NoneNoneELIGIBILITYReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNone
17077333710000NoneNoneELIGIBILITYQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNone
17077333710000NoneNoneELIGIBILITYProposals for subcontracting components of works amounting to more than 20% of the contract price (for each, the qualifications and experience of the identified sub-contractor in the relevant fields should be attached)None
17077333710000NoneNoneELIGIBILITYOTHER CONDITIONS APPLY ACCORDING TO KW-2 DOCUMENTNone
17077333710000NoneNoneELIGIBILITYEstimations are prepared excluding the 18 percent GSTNone
preQualCriterionListNone
technicalCriterionListNone
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
PWD Registration CertificateTrueTechnical Bid
Similar nature of work done CertificateTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone