| 2381850 | 70829 | None | BLK001 | CONSTRUCTION OF ONE ROOM HPS SCHOOL BUILDING AT LINGAPUR SK VILLAGE OF BILAGI TALUKA : Earth work excavation by manual means for drains,canals and similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, re moval of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sort ing & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.complete with all lead and lift and as per the direction of Engineer in charge of work. | Cum | 195.3 | 195.3 | 43.27 | False | None | None | False | None | False | 8450.631 | 0 |
| 2381851 | 70829 | None | BLK002 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) (PWD SR 2021-22 / Volumme I /I.NO-2.1.2 /P.NO-15) | Cum | 5466.3 | 5466.3 | 6.42 | False | None | None | False | None | False | 35093.646 | 0 |
| 2381852 | 70829 | None | BLK003 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates (PWD SR 2021-22 / Volumme I / I.NO-2.2.1.1 /P.NO-15)complete with all lead and lift and as per the direction of Engineer in charge of work. | Cum | 6240.15 | 6240.15 | 11.08 | False | None | None | False | None | False | 69140.862 | 0 |
| 2381853 | 70829 | None | BLK004 | For Centering according to the Table For Finished Concrete ( P.No A-7 Volume II ) i.e = FOOTING complete with all lead and lift and as per the direction of Engineer in charge of work.Rate 5% of I No.3 | Cum | 312.01 | 312.01 | 11.08 | False | None | None | False | None | False | 3457.0708 | 0 |
| 2381854 | 70829 | None | BLK005 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates (PWD SR 2021-22 / Volumme I / I.NO-2.5.1 /P.NO-17)complete with all lead and lift and as per the direction of Engineer in charge of work. | Cum | 6491.1 | 6491.1 | 16.59 | False | None | None | False | None | False | 107687.349 | 0 |
| 2381855 | 70829 | None | BLK006 | For Centering according to the Table For Finished Concrete ( P.No A-7 Volume II ) i.e = Column complete with all lead and lift and as per the direction of Engineer in charge of work.Rate 70% of I No.5 | Cum | 4543.77 | 4543.77 | 3.41 | False | None | None | False | None | False | 15494.2557 | 0 |
| 2381856 | 70829 | None | BLK007 | For Centering according to the Table For Finished Concrete ( P.No A-7 Volume II ) i.e = Plinth Beam complete with all lead and lift and as per the direction of Engineer in charge of work. Rate 50% of I No.5 | Cum | 3245.55 | 3245.55 | 1.26 | False | None | None | False | None | False | 4089.393 | 0 |
| 2381857 | 70829 | None | BLK008 | For Centering according to the Table For Finished Concrete ( P.No A-7 Volume II ) i.e = Roof Beam & lintel complete with all lead and lift and as per the direction of Engineer in charge of work.Rate 60% of I No.5 | Cum | 3894.66 | 3894.66 | 4.56 | False | None | None | False | None | False | 17759.6496 | 0 |
| 2381858 | 70829 | None | BLK009 | For Centering according to the Table For Finished Concrete ( P.No A-7 Volume II ) i.e = Slab complete with all lead and lift and as per the direction of Engineer in charge of work.Rate 50% of I No.5 | Cum | 3245.55 | 3245.55 | 7.17 | False | None | None | False | None | False | 23270.5935 | 0 |
| 2381859 | 70829 | None | BLK010 | For Centering according to the Table For Finished Concrete ( P.No A-7 Volume II ) i.e = Chejja complete with all lead and lift and as per the direction of Engineer in charge of work.Rate 45% of I No.5 | Cum | 2921.0 | 2921.0 | 0.18 | False | None | None | False | None | False | 525.78 | 0 |
| 2381860 | 70829 | None | BLK011 | Providing Thermo-Mechanically Treated bars of grade Fe-550D or more Steel reinforcement for R.C.C. work including straightening, cut ting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) (PWD SR 2021-22 / Volumme II / I.NO-11.32 /P.NO-84)complete with all lead and lift and as per the direction of Engineer in charge of work. | Kg | 100.8 | 100.8 | 2376.9 | False | None | None | False | None | False | 239591.52 | 0 |
| 2381861 | 70829 | None | BLK012 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.. (PWD SR 2021-22 / Volumme II / I.NO-6.2 /P.NO-13)complete with all lead and lift and as per the direction of Engineer in charge of work. | Cum | 7030.8 | 7030.8 | 6.16 | False | None | None | False | None | False | 43309.728 | 0 |
| 2381862 | 70829 | None | BLK013 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. (PWD SR 2021-22 / Volumme II / I.NO-6.7 /P.NO-13)complete with all lead and lift and as per the direction of Engineer in charge of work. | Cum | 7295.4 | 7295.4 | 19.56 | False | None | None | False | None | False | 142698.024 | 0 |
| 2381863 | 70829 | None | BLK014 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.(The laps and wastages shall not be measured separately) (PWD SR 2021-22 / Volumme I / I.NO-1.8 /P.NO-7)complete with all lead and lift and as per the direction of Engineer in charge of work. | Cum | 422.1 | 422.1 | 44.18 | False | None | None | False | None | False | 18648.378 | 0 |
| 2381864 | 70829 | None | BLK015 | Providing and laying Cement concrete pavement with 1:2:4 for commercial & residential building floors, hardpaths, footpaths using 1 ce ment : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size, including finishing complete as per Engineer incharge (PWD SR 2021-22 / Volumme II / I.NO-9.4 /P.NO-59) complete with all lead and lift and as per the direction of Engineer in charge of work. | Cum | 6510.0 | 6510.0 | 15.57 | False | None | None | False | None | False | 101360.7 | 0 |
| 2381865 | 70829 | None | BLK016 | Flooring with 25mm thick polished shahabad slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications.(PWD SR 2021-22 / Volumme II / I.NO- 9.35 /P.NO-64) complete with all lead and lift and as per the direction of Engineer in charge of work. | Sqm | 1377.6 | 1377.6 | 59.43 | False | None | None | False | None | False | 81870.768 | 0 |
| 2381866 | 70829 | None | BLK017 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge..:(PWD SR 2021-22 / Volumme II / I.NO-8.3.2 /P.NO-41) complete with all lead and lift and as per the direction of Engineer in charge of work. | Sqm | 289.8 | 289.8 | 236.12 | False | None | None | False | None | False | 68427.576 | 0 |
| 2381867 | 70829 | None | BLK018 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement:6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.complete with all lead and lift and as per the direction of Engineer in charge of work. | Sqm | 223.65 | 223.65 | 50.56 | False | None | None | False | None | False | 11307.744 | 0 |
| 2381868 | 70829 | None | BLK019 | Poviding and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(PWD SR 2021-22 / Volumme II / I.NO-8.51 /P.NO-51) complete with all lead and lift and as per the direction of Engineer in charge of work. | Sqm | 87.15 | 87.15 | 112.15 | False | None | None | False | None | False | 9773.8725 | 0 |
| 2381869 | 70829 | None | BLK020 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per
specifications and as per directions of Engineer-in-charge.(PWD SR 2021-22 / Volumme II / I.NO- 8.33.1 /P.NO-46) | Sqm | 123.9 | 123.9 | 249.42 | False | None | None | False | None | False | 30903.138 | 0 |
| 2381870 | 70829 | None | BLK021 | Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 ems c/c both horizontally and vertically fixed with chicken mesh for drop chajja, facia, backing to cup boards including cost of all materials, labour, providing and removing form work HOM curing, complete as per specifications.Specification No. KBS .(PWD SR 2021-22 / Volumme III / 1st Addl Sl.NO- 8 ) complete with all lead and lift and as per the direction of Engineer in charge of work. | Sqm | 1262.1 | 1262.1 | 5.36 | False | None | None | False | None | False | 6764.856 | 0 |
| 2381871 | 70829 | None | BLK022 | Providing and fixing M.S. grills of required pattern in frames of win dows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.:(PWD SR 2021-22 / Volumme II / I.NO-11.34 B /P.NO-85) complete with all lead and lift and as per the direction of Engineer in charge of work. | Kg | 166.95 | 166.95 | 113.4 | False | None | None | False | None | False | 18932.13 | 0 |
| 2381872 | 70829 | None | BLK023 | Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves ( excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. :(PWD SR 2021-22 / Volumme II / I.NO-12.11 /P.NO-99)complete with all lead and lift and as per the direction of Engineer in charge of work. | Cum | 94912.65 | 94912.65 | 0.3 | False | None | None | False | None | False | 28473.795 | 0 |
| 2381873 | 70829 | None | BLK024 | Providing and fixing in position fully panelled Honne wood shutters for doors with ,stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials,labour, usage charges complete as per specifications. (excluding cost of fixtures):(PWD SR 2021-22 / Volumme II / I.NO-12.17 /P.NO-100)complete with all lead and lift and as per the direction of Engineer in charge of work. | Sqm | 5109.3 | 5109.3 | 4.22 | False | None | None | False | None | False | 21561.246 | 0 |
| 2381874 | 70829 | None | BLK025 | Providing and fixing in position Honnewood fully panelled shutters for windows with stiles and rails of 35mm. thick, 75mm wide in two halves with panels of 25mm thick including cost of materials, labour charges, usage charges complete as per specifications. (excluding cost of fixtures) (PWD SR 2021-22 / Volumme II / I.NO-12.23 /P.NO-101)complete with all lead and lift and as per the direction of Engineer in charge of work. | Sqm | 5441.1 | 5441.1 | 3.98 | False | None | None | False | None | False | 21655.578 | 0 |
| 2381875 | 70829 | None | BLK026 | Providing and Fixing Fixtures for Door Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc.12.68.1 125x65x2.12mm (PWD SR 2021-22 / Volumme II / I.NO-12.68.1 /P.NO-107)complete with all lead and lift and as per the direction of Engineer in charge of work. | Each | 39.9 | 39.9 | 24.0 | False | None | None | False | None | False | 957.6 | 0 |
| 2381876 | 70829 | None | BLK027 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. 10.6.3 Wedge expansion type Fastener with (PWD SR 2021-22 / Volumme II / I.NO- 10.6.3 /P.NO-69)complete with all lead and lift and as per the direction of Engineer in charge of work. | Each | 31.5 | 31.5 | 24.0 | False | None | None | False | None | False | 756.0 | 0 |
| 2381877 | 70829 | None | BLK028 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete (PWD SR 2021-22 / Volumme II / I.NO- 12.62 /P.NO-107)complete with all lead and lift and as per the direction of Engineer in charge of work. | Each | 183.75 | 183.75 | 16.0 | False | None | None | False | None | False | 2940.0 | 0 |
| 2381878 | 70829 | None | BLK029 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete (PWD SR 2021-22 / Volumme II / I.NO- 12.63 /P.NO-107)complete with all lead and lift and as per the direction of Engineer in charge of work. | Each | 116.55 | 116.55 | 22.0 | False | None | None | False | None | False | 2564.1 | 0 |
| 2381879 | 70829 | None | BLK030 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42mm with suitable washers weighing not less than 33 gms (PWD SR 2021-22 / Volumme II / I.NO- 12.64 /P.NO-107). complete.complete with all lead and lift and as per the direction of Engineer in charge of work. | Each | 49.35 | 49.35 | 4.0 | False | None | None | False | None | False | 197.4 | 0 |
| 2381880 | 70829 | None | BLK031 | Providing and fixing on wall face unplasticized Rigid PVC rain water pipes Confirming IS : 13592 Type A, including Jointing with seal ring Confirming IS : 5382, leaving 10mm gap for thermal Expansion i) Single socketed pipes 75mm diameters (PWD SR 2021-22 / Volumme II / Addl Sl.No - 24 ).complete with all lead and lift and as per the direction of Engineer in charge of work. | m | 185.85 | 185.85 | 6.0 | False | None | None | False | None | False | 1115.1 | 0 |
| 2381881 | 70829 | None | BLK032 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying (PWD SR 2021-22 / Volumme II / I.NO- 11.26.1 /P.NO- 82) complete with all lead and lift and as per the direction of Engineer in charge of work. | Kg | 116.55 | 116.55 | 78.38 | False | None | None | False | None | False | 9135.189 | 0 |
| 2381882 | 70829 | None | BLK033 | ELECTRIFICATION : Supplying and wiring adopting loop system in existing PVC Conduit/casing caping using 1100V grade,copper conductor fexibele multistrand FRLS PVC insulated, 2 x 1.5 Sqmm cable conferming to GTP,with a 6AMPS flush type SP Controll switch shal be fixed on existing plastic sheet or Gang box, the other end of the wires shall be terminated wiht sufficeint loose length in a wood or PVC round block. complete for each outlet.---do ----a)Shrot Point upto 3mtr from taping point to outlet via switch (PWD BGM SR Electricl Pg.No.5 It.No.2.1.1)complete with all lead and lift and as per the direction of Engineer in charge of work. | Nos. | 210.0 | 210.0 | 5.0 | False | None | None | False | None | False | 1050.0 | 0 |
| 2381883 | 70829 | None | BLK034 | Supplying and wiring adopting loop system in existing PVC Conduit/casing caping using 1100V grade,copper conductor fexibele multistrand FRLS PVC insulated, 2 x 1.5 Sqmm cable conferming to GTP,with a 6AMPS flush type SP Controll switch shal be fixed on existing plastic sheet or Gang box, the other end of the wires shall be terminated wiht sufficeint loose length in a wood or PVC round block. complete for each outlet- Mediumpoint above 3Mtr upto 6Mtr from tapping point to out let via switch (PWD BGM SR Electricl Pg.No.5 It.No.2.1.2)complete with all lead and lift and as per the direction of Engineer in charge of work. | Nos. | 288.75 | 288.75 | 2.0 | False | None | None | False | None | False | 577.5 | 0 |
| 2381884 | 70829 | None | BLK035 | Supplying and wiring adopting loop system in existing PVC Conduit/casing caping using 1100V grade,copper conductor fexibele multistrand FRLS PVC insulated, 2 x 1.5 Sqmm cable conferming to GTP,with a 6AMPS flush type SP Controll switch shal be fixed on existing plastic sheet or Gang box, the other end of the wires shall be terminated wiht sufficeint loose length in a wood or PVC round block. complete for each outlet- Long point above 6Mtr upto 10 Mtr from tapping point to out let via switch (PWD BGM SR Electricl Pg.No.5 It.No.2.1.3)complete with all lead and lift and as per the direction of Engineer in charge of work. | Nos. | 420.0 | 420.0 | 2.0 | False | None | None | False | None | False | 840.0 | 0 |
| 2381885 | 70829 | None | BLK036 | Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in a existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654. -do- 6 Amps 3/5 Way (PWD BGM SR Electricl Pg.No.15 It.No.3.1.2)complete with all lead and lift and as per the direction of Engineer in charge of work. | Nos. | 138.6 | 138.6 | 4.0 | False | None | None | False | None | False | 554.4 | 0 |
| 2381886 | 70829 | None | BLK037 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete. -do- 10"x7"x3" (254x178x76mm) (PWD BGM SR Electricl Pg.No.3 It.No.1.6.3)complete with all lead and lift and as per the direction of Engineer in charge of work. | Nos. | 91.35 | 91.35 | 2.0 | False | None | None | False | None | False | 182.7 | 0 |
| 2381887 | 70829 | None | BLK038 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300mm …. etc. as required.25mm (PWD BGM SR Electricl Pg.No.3 It.No.1.8.2)complete with all lead and lift and as per the direction of Engineer in charge of work. | m | 25.2 | 25.2 | 30.0 | False | None | None | False | None | False | 756.0 | 0 |
| 2381888 | 70829 | None | BLK039 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper conductor single core wire in open or concealed system of wiring as per IS-694:1990 & confirming to GTP of GROUP-B.-do- 1.5 Sqmm (PWD BGM SR Electricl Pg.No.6 It.No.1.6.2)complete with all lead and lift and as per the direction of Engineer in charge of work. | m | 16.7 | 16.7 | 50.0 | False | None | None | False | None | False | 835.0 | 0 |
| 2381889 | 70829 | None | BLK040 | Supplying and fixing regular MCB distribution boards on wall/wood board/flush mounting using required clamps, bolts, nuts etc., with provision for fixing of suitable type capacity MCB's single phase /3phase /single door with powder coated painting. Made out of 14 SWG MS enclosure.-do- I) Single Door, 4 Way SP & N (PWD BGM SR Electricl Pg.No.28 It.No.5.18.1) | Nos. | 815.85 | 815.85 | 4.0 | False | None | None | False | None | False | 3263.4 | 0 |
| 2381890 | 70829 | None | BLK041 | Supplying And Fixing of regular MCB distribution boards on wall / wood board / flush mounting using required clamps bolts nuts etc.. With provision for fixing suitable type capacity MCBsingle phase / 3 phase / single door with powder coated painting made out of 14 SWG enclosure ii Double Door (Electrical SR 14-15 P.NO-47/I.NO-6.17.3)complete with all lead and lift and as per the direction of Engineer in charge of work. | Each | 1099.35 | 1099.35 | 1.0 | False | None | None | False | None | False | 1099.35 | 0 |
| 2381891 | 70829 | None | BLK042 | Supplying patti type fluorescent tube light fitting of 4'- suitable for 28 watts fluorescent tube fitting, made out of M.S sheet and stove enameled with HF Electronic Ballast locking type brass contact holders mounted on double fold type sheet base fully wired for use on 230 Volts AC supply including T5 lamp.(PWD BGM SR Electricl Pg.No.20 It.No.4.6)complete with all lead and lift and as per the direction of Engineer in charge of work. | Each | 1008.0 | 1008.0 | 3.0 | False | None | None | False | None | False | 3024.0 | 0 |
| 2381892 | 70829 | None | BLK043 | Fixing all types and all capacities fluorescent/false ceiling/spot light/CFL fittings indoor on the wall / ceiling/ rafters/girders using 23/0.0076" twin twisted PVC insulated wires, required nos of round blocks and clamps. -do- On wall/ceiling/Rafter/Girders (PWD BGM SR Electricl Pg.No.79 It.No.14.7.1)complete with all lead and lift and as per the direction of Engineer in charge of work. | Each | 115.5 | 115.5 | 3.0 | False | None | None | False | None | False | 346.5 | 0 |
| 2381893 | 70829 | None | BLK044 | Fixing a ceiling/wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23/0.0076 inch PVC insulated twin twisted copper wire and wiring. (PWD BGM SR Electricl Pg.No.80 It.No.14.8)complete with all lead and lift and as per the direction of Engineer in charge of work. | Each | 157.5 | 157.5 | 2.0 | False | None | None | False | None | False | 315.0 | 0 |
| 2381894 | 70829 | None | BLK045 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system.-do- 56" Sweep (1400mm). Economy model (PWD BGM SR Electricl Pg.No.46 It.No.7.3.2)complete with all lead and lift and as per the direction of Engineer in charge of work. | Each | 2233.35 | 2233.35 | 2.0 | False | None | None | False | None | False | 4466.7 | 0 |
| 2381895 | 70829 | None | BLK046 | Supplying And Fixing of modular switch/stepped electroniv fan regulator on existing modular switch as per IS 3854 And IS 1293 Group A (Electrical SR P.NO-16/I.NO-3.7.6)complete with all lead and lift and as per the direction of Engineer in charge of work. | Each | 565.95 | 565.95 | 2.0 | False | None | None | False | None | False | 1131.9 | 0 |
| 2381896 | 70829 | None | BLK047 | Supplying fixing And Wiring Eath Leakage Miniature Circuit Breaker(ELMCB)240V/250V upto 300A sensitivity on Esisting Wood/panel board (Electrical SR P.NO-47/I.NO-6.18.2)complete with all lead and lift and as per the direction of Engineer in charge of work. | Each | 2754.15 | 2754.15 | 1.0 | False | None | None | False | None | False | 2754.15 | 0 |
| 2381897 | 70829 | None | BLK048 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipments on the meter board using 40mm dia 2.90 thick GI pipe 2.5mtr long buried in a pit. The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 122mm dia. (PWD BGM SR Electricl 19-20 Pg.No.40 It.No.6.1)complete with all lead and lift and as per the direction of Engineer in charge of work. | Each | 3149.69 | 3149.69 | 1.0 | False | None | None | False | None | False | 3149.69 | 0 |