createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1707409978013
version2
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeONE_COVER
evaluationTypeTextOne Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee500.00
emd24000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose21-02-2024 16:30:00
tenderQueryClose20-02-2024 16:30:00
technicalBidOpenNone
publishedDate13-02-2024 16:35:05
publishedByPostTP_CO_DVHP
publishedByUserKPE15358 - LALSAB DAWALSAB MULLA
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonGururaj B
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedNone
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber6360589770
tenderSupplierListNone
tenderSchedule
createdTs1707409978042
version4
createdDateNone
modifiedDateNone
tenderNumberDMA/2023-24/WS/WORK_INDENT13865
titleConstruction of RO Plant in back garden of tahsildar office in ward no 11
descriptionConstruction of RO Plant in back garden of tahsildar office in ward no 11
categoryWORKS
categoryTextWorks
ecv955974.66
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2250
locationNameDMA Town Panchayat DevaraHipparagi
provisionalAmount1150000.0
groupOverheadTotalNone
fileNumberNMPC/2021-22/970/2023-24
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17074099780000NoneNoneWater supply/sewage linesConstruction of RO Plant in back garden of tahsildar office in ward no 11955974.66
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
251811376766Nonecode01Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in aradius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In All Types of Soil Depth Upto 3MtrsCum105.06105.0632.556FalseNoneNoneFalseNoneFalse3420.333360
251811476766Nonecode02Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum6168.676168.672.5542FalseNoneNoneFalseNoneFalse15756.0169140
251811576766Nonecode03Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand :12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand)Cum5779.335779.337.4339FalseNoneNoneFalseNoneFalse42962.9612870
251811676766Nonecode04Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6580.676580.678.0271FalseNoneNoneFalseNoneFalse52823.6961570
251811776766Nonecode05Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregatesCum6403.516403.512.541FalseNoneNoneFalseNoneFalse16271.318910
251811876766Nonecode06Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6828.96828.91.0984FalseNoneNoneFalseNoneFalse7500.863760
251811976766Nonecode07Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)Tonne92140.7192140.710.0934FalseNoneNoneFalseNoneFalse8605.9423140
251812076766Nonecode08Providing 15 mm cement plaster on rough side of single or half brick wallfinished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge 1) Refer Appendix-I For Formwork, Centering, Scaffolding of plastering is 25% (Pg No 115 of Common SR 2021-22)Sqm359.47359.4714.328FalseNoneNoneFalseNoneFalse5150.486160
251812176766Nonecode09Water purification plants: Providing, Installation and Commissioning of automatic Water purification plant (RO+UF) with all accessories piping, product water tank on single phase power supply as per the enclosed detailed Technical Specifications including cost of material, loading and unloading and as directed by the Engineer in charge. (Ref- detailed specification enclosed seperatly). Note:- 1.The above rates mentioned are only for the preparation of estimate purpose. 2. All items are to be of BSI /NFS standards,with BSI / NFS mark . 3. Tenders to be invited for procurement. 4. No direct payment should be made under any situation or condition or on any account. 5. After commissioning of plant necessary testing to be done for the satisfactory of Engineer Incharge. Note : Refer the ANNEXURE : F for Detailed Specification of Each components for 1000lph skid type Page No.247 Item No.21.1.9 V5 BWSSBSqm454230.0454230.01.0FalseNoneNoneFalseNoneFalse454230.00
251812276766Nonecode10Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Refer Appendix-I For Formwork, Centering, Scaffolding of painting is 25% (Pg No 115 of Common SR 2021-22)Sqm162.74162.7417.7FalseNoneNoneFalseNoneFalse2880.4980
251812376766Nonecode11Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cemen slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mmSqm1179.351179.3512.5FalseNoneNoneFalseNoneFalse14741.8750
251812476766Nonecode12Providing & fixing of 2-track x 2-panel sliding windows made out of multichambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm5173.695173.691.7999FalseNoneNoneFalseNoneFalse9312.1246310
251812576766Nonecode13Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.20 mm M.S. laths with 1.20 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm2578.092578.094.5FalseNoneNoneFalseNoneFalse11601.4050
251812676766Nonecode14Providing & fixing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge.0.63 mm thick with zinc coating not less than 275 g/ m²Cum905.37905.3779.4FalseNoneNoneFalseNoneFalse71886.3780
251812776766Nonecode15Providing & fixing ridges or hips of width 60 cm overall width plain G.S.sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I.limpet and bitumen washers complete as per design drawings.0.63 mm thick with zinc coating not less than 275 g/m²m658.17658.175.0FalseNoneNoneFalseNoneFalse3290.850
251812876766Nonecode16Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg140.08140.08315.923FalseNoneNoneFalseNoneFalse44254.493840
251812976766Nonecode17Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. On wall/ ceiling / Rafter / GirdersEach125.66125.661.0FalseNoneNoneFalseNoneFalse125.660
251813076766Nonecode18For Electrical & Hescom ChargesEach5150.05150.01.0FalseNoneNoneFalseNoneFalse5150.00
251813176766Nonecode19Sinking of Borewell of 165mm dia clear using super fast hydraulic Rig of capacity 250 PSIG &above 900 CFM & above in all strata including over burden upto 20mtrs. Fixing of casing pipes, collars &cap with necessary cutting,threading & welding including transportation of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour(excluding cost of casing pipes collars and cap etc.) (BWSSB SR 2023-24 P No. 139 It No 12.1.1,12. 1.2,12. 1.3)0 to 50 mtr depthm381.1381.150.0FalseNoneNoneFalseNoneFalse19055.00
251813276766Nonecode20Above 50 mtr upto 100 mtrm477.92477.9250.0FalseNoneNoneFalseNoneFalse23896.00
251813376766Nonecode21Above 100 mtr upto 150 mtrm507.79507.7950.0FalseNoneNoneFalseNoneFalse25389.50
251813476766Nonecode22Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing5.10kg/m.prices include Collar-Medium duty. Providing 160 mm casing pipe with M.S. coller (BWSSB SR 2023-24 P No. 134 It No 12.32)m1990.991990.9913.0FalseNoneNoneFalseNoneFalse25882.870
251813576766Nonecode23Providing and laying at site of work MS casing caps as per IS 1239 (part- II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer Providing 200mm PVC casing cap including fixing charges (BWSSB SR 2021-22 P No. 134 It No 12.34)No168.92168.921.0FalseNoneNoneFalseNoneFalse168.920
251813676766Nonecode24Geophysical Investigation of site for sinking Borewell Geophysical Investigation of site for sinking Borewell for supplying drinking water to the habitation either through a hand pump, Mini Water Supply scheme, or Piped Water Supply Scheme by vertical electrical sounding by adopting venner or Schlumberger's method, including reconnaissance survey of geological formation, geophysical investigation of existing ground water in the vicinity, its quality, quantity & acceptability of the users indicating the location of site, recommended depth of casing pipe required to seal the top unconsolidated formation incluing an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instrument and accessories to work site, engaging technical personal and labour required etc., complete.(BWSSB SR 2023-24 P No. 151 It No 12.4)No5446.645446.641.0FalseNoneNoneFalseNoneFalse5446.640
251813776766Nonecode25Providing, supplying to work site,Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications,with testing of as per instructions of engineer incharge of work and latest amendments.5.00 HP/1.5KW 12 STG .(BWSSB SR 2023-24 P No. 150 It No 13.7.5) (H.P -1. 5 / 3.7KW Stage 15 Head 100.00 Mtr)Set17448.217448.21.0FalseNoneNoneFalseNoneFalse17448.20
251813876766Nonecode26Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Upto 3 HP pumps (BWSSB SR 2023-24 P No. 154 It No 13.23)Set6695.06695.01.0FalseNoneNoneFalseNoneFalse6695.00
251813976766Nonecode27Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. Note: Upto 110mm dia Coil shall be used. For Grade PE80 PN6.0 : HDPE Grade PE80-PN6.0, 63mm dia m 63 mm dia.(BWSSB SR 2023-24 P No. 95 It No 9.1.1)m194.67194.67120.0FalseNoneNoneFalseNoneFalse23360.40
251814076766Nonecode28SubmersibleCable: Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1x3x4 Sqm.(BWSSB SR 2023-24 P No. 154 It No 13.22.3)m139.05139.05135.0FalseNoneNoneFalseNoneFalse18771.750
251814176766Nonecode29Pressure Guage: Supply and Delevery of brand new best make pressure guage (Bourdon Type size confirming to IS 3624/87 with latest amendments with ISI mark as provided in SPD rate contract. .(BWSSB SR 2023-24 P No. 154 It No 13.23.1)No428.48428.481.0FalseNoneNoneFalseNoneFalse428.480
251814276766Nonecode30Supply and delivery best indegeneous brand new power capacitor as per IS 283/86 with latest amendments with ISI mark of required capacity tested and approved by one KEB aouthorities and erection. Electrification and commissioning of the same at the location of the respective pumpsets as provided in SPD rate contract . (BWSSB SR 2023-24 P No. 151 It No 13.25)Kvar566.5566.51.0FalseNoneNoneFalseNoneFalse566.50
251814376766Nonecode31Supply and delivery at site delivery of best indigenous brand new MCB (Miniature Circuit Breakers) of required capacity as per IS 88228/1978 and its latest amendments and with ISI Mark of 6/10/16/20/25/40 Amps with scalable box.(BWSSB SR 2023-24 P No. 155 It No 13.26) Per 3 polseNo1184.51184.51.0FalseNoneNoneFalseNoneFalse1184.50
251814476766Nonecode32Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work.(BWSSB SR 2023-24 P No. 156 It No 13.33)Job1390.51390.51.0FalseNoneNoneFalseNoneFalse1390.50
251814576766Nonecode33Providing main connection from pole PVC insulated sheathed steel wire cable in new trench as per IS 1554/ 1988 with latest amendments with ISI mark from KPTCL pole to meter board unit..(BWSSB SR 2023-24 P No. 156 It No 13.36)Mtr139.05139.0530.0FalseNoneNoneFalseNoneFalse4171.50
251814676766Nonecode34Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. (BWSSB SR 2023-24 P No. 157 It No 13.39)Job3862.53862.51.0FalseNoneNoneFalseNoneFalse3862.50
251814776766Nonecode35Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments 65 mm dia non return valve (BWSSB SR 2023-24 P No. 154 It No 13.25.2)Each1596.51596.51.0FalseNoneNoneFalseNoneFalse1596.50
251814876766Nonecode36Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. (BWSSB SR 2023-24 P No. 156 It No 13.32)Job6695.06695.01.0FalseNoneNoneFalseNoneFalse6695.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17074099790000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17074099790000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17074099790000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17074099790000NoneNoneELIGIBILITYDepartment Registration DetailsNone
17074099790000NoneNoneELIGIBILITYTotal value of civl engineering works executed and payments received in the last five years (year-wise)None
17074099790000NoneNoneELIGIBILITYList of existing commitments and ongoing workNone
17074099790000NoneNoneELIGIBILITYList of works for which tenders already submittedNone
17074099790000NoneNoneELIGIBILITYBanker DetailsNone
preQualCriterionListNone
technicalCriterionListNone
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Valid KPWD licenceTrueTechnical Bid
Annual turnover certificate from last five years Achieved in at least two financial years an average annual turnover of Rs 23.00 lakhs Two times of the tender valueTrueTechnical Bid
satisfactory completed as a prime contractor at least one similar nature work to an extent of 50 Percentage of the cost value not less than RS 5.5 lakhsTrueTechnical Bid
LOC 30 percentage an amounting of 3.50 lakhs as per the FD order 22-08-2022 and find the attachment belowTrueTechnical Bid
Below DD Shold be Submitted before last day of tender SubmissionTrueTechnical Bid
GST and PAN card certificateTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone