2592266 | 80674 | None | code01 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge | Cum | 2547.3 | 2547.3 | 2.8 | False | None | None | False | None | False | 7132.44 | 0 |
2592267 | 80674 | None | code02 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates - For flooring (PWD SR Vol-1 2023-24; P.No. 15; Serial NO. 2.1.4) | Cum | 5947.2 | 5947.2 | 15.84 | False | None | None | False | None | False | 94203.648 | 0 |
2592268 | 80674 | None | code03 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2 including pointing in white cement mixed with pigment of matching shade complete. (PWD SR Vol-2 2023-24; P.No. 60; Serial NO.9.10) | Sqm | 1161.3 | 1161.3 | 158.4 | False | None | None | False | None | False | 183949.92 | 0 |
2592269 | 80674 | None | code04 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-incharge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) including cost of materials, labour, usage charges of machinery complete as per specifications (PWD SR Vol-2 2023-24; P.No. 87; Serial NO.11.35.1.1) | Kg | 474.6 | 474.6 | 200.55 | False | None | None | False | None | False | 95181.03 | 0 |
2592270 | 80674 | None | code05 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer- in-charge: Pre-laminated particle board with decorative lamination on both sides including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (PWD SR Vol-2 2023-24; P.No. 89; Serial NO.11.36.2) | Sqm | 1032.15 | 1032.15 | 50.6 | False | None | None | False | None | False | 52226.79 | 0 |
2592271 | 80674 | None | code06 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/m²) including cost of materials, labour, usage charges of machinery complete as per specifications. (PWD SR Vol-2 2023-24; P.No. 89; Serial NO.11.37.2) | Sqm | 1229.55 | 1229.55 | 27.0 | False | None | None | False | None | False | 33197.85 | 0 |
2592272 | 80674 | None | code07 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m (PWD SR Vol-1 2023-24; P.No. 5; Serial NO.1.4.1) | Cum | 254.1 | 254.1 | 13.2 | False | None | None | False | None | False | 3354.12 | 0 |
2592273 | 80674 | None | code08 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (PWD SR Vol-1 2023-24; P.No. 15; Serial NO. 2.2.1) | Cum | 6601.35 | 6601.35 | 0.9 | False | None | None | False | None | False | 5941.215 | 0 |
2592274 | 80674 | None | code09 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. (PWD SR Vol-2 2023-24; P.No. 13; Serial NO. 6.1) | Cum | 8631.0 | 8631.0 | 8.39 | False | None | None | False | None | False | 72414.09 | 0 |
2592275 | 80674 | None | code10 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (PWD SR Vol-1 2023-24; P.No. 16; Serial NO. 2.4.2) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Add. Percentage on finished rate of concrete per m3 for Roof Slab as per Addendum 1 - 50%) | Cum | 9958.73 | 9958.73 | 0.76 | False | None | None | False | None | False | 7568.6348 | 0 |
2592276 | 80674 | None | code11 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications (PWD SR Vol-1 2023-24; P.No. 16; Serial NO. 2.5.2) (Add. % on Finished concrete rate for Centering & Shuttering - Beam) - 50% | Cum | 10442.25 | 10442.25 | 1.08 | False | None | None | False | None | False | 11277.63 | 0 |
2592277 | 80674 | None | code12 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. (PWD SR Vol-1 2023-24; P.No. 18; Serial NO. 2.11 h) | MT | 82961.55 | 82961.55 | 0.11 | False | None | None | False | None | False | 9125.7705 | 0 |
2592278 | 80674 | None | code13 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD SR Vol-2 2023-24; P.No. 41; Serial NO.8.1.2) | Sqm | 253.05 | 253.05 | 83.76 | False | None | None | False | None | False | 21195.468 | 0 |
2592279 | 80674 | None | code14 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (PWD SR Vol-2 2023-24; P.No. 100; Serial NO.12.13.1) | Cum | 103755.75 | 103755.75 | 0.09 | False | None | None | False | None | False | 9338.0175 | 0 |
2592280 | 80674 | None | code15 | Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with , stiles and rails of 30mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) (PWD SR Vol-2 2023-24; P.No. 100; Serial NO.12.21) | Sqm | 6029.1 | 6029.1 | 3.6 | False | None | None | False | None | False | 21704.76 | 0 |
2592281 | 80674 | None | code16 | Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. (PWD SR Vol-2 2023-24; P.No. 77; Serial NO. 11.2) Dogs Cage 0.9m X 0.75m ( Made of Stainless Steel 8 mm bars ) | Kg | 118.65 | 118.65 | 500.0 | False | None | None | False | None | False | 59325.0 | 0 |
2592282 | 80674 | None | code17 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (PWD SR Vol-2 2023-24; P.No. 85; Serial NO. 11.28) | Kg | 593.25 | 593.25 | 96.0 | False | None | None | False | None | False | 56952.0 | 0 |
2592283 | 80674 | None | code18 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. (PWD SR Vol-2 2023-24; P.No. 122; Serial NO.13.32.2) 20 mm nominal dia pipes | m | 397.95 | 397.95 | 50.0 | False | None | None | False | None | False | 19897.5 | 0 |
2592284 | 80674 | None | code19 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work (PWD SR Vol-2 2023-24; P.No. 125; Serial NO.13.50.6) 50 mm nominal dia Pipes | m | 405.3 | 405.3 | 50.0 | False | None | None | False | None | False | 20265.0 | 0 |
2592285 | 80674 | None | code20 | Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately. (PWD SR Vol-2 2023-24; P.No. 123; Serial NO.13.34A) | l | 9.45 | 9.45 | 1500.0 | False | None | None | False | None | False | 14175.0 | 0 |
2592286 | 80674 | None | code21 | Constructing soak pit 1.20x1.20x1.20 m filled with brickbats including PVC (S.W.R) drain pipe 100 mm diameter and 1.20 m long complete as per standard design. (PWD SR Vol-2 2023-24; P.No. 127; Serial NO.13.57) | No | 2823.0 | 2823.0 | 1.0 | False | None | None | False | None | False | 2823.0 | 0 |
2592287 | 80674 | None | code22 | Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. Page No. 02 1.1.4 I - Point wiring using class A materials. | Mtr | 149.0 | 149.0 | 44.3 | False | None | None | False | None | False | 6600.7 | 0 |
2592288 | 80674 | None | code23 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc 1.4.7 Page No. 02 (200x200x65mm) | Each | 348.0 | 348.0 | 15.0 | False | None | None | False | None | False | 5220.0 | 0 |
2592289 | 80674 | None | code24 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete 1.4.7 Page No. 03 (12" x 12" x 3" (300 x 300 x 76 mm)) | Each | 120.0 | 120.0 | 10.0 | False | None | None | False | None | False | 1200.0 | 0 |
2592290 | 80674 | None | code25 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete 1.4.7 Page No. 03 (8" x 6" x 3" (203 x 152 x 76 mm) | Each | 86.0 | 86.0 | 10.0 | False | None | None | False | None | False | 860.0 | 0 |
2592291 | 80674 | None | code26 | Supplying & Fixing of 230 V 20/40 W Fluorescent Lamp holder 12.45 page no. 52 | No | 33.0 | 33.0 | 10.0 | False | None | None | False | None | False | 330.0 | 0 |
2592292 | 80674 | None | code27 | Supplying & fixing LED Drivers suitable for 5700K LED fitting Indoor Fixtures. Operating voltage range from 180V to 265V, 50Hz AC power Supply 12.51 page no. 53 (upto 3W 5700K suitable for indoor LED fitting 12.51.1 page no. 53) | No | 275.0 | 275.0 | 10.0 | False | None | None | False | None | False | 2750.0 | 0 |
2592293 | 80674 | None | code28 | Supplying 6A flush type socket and 6 A flush type SP switch either surface /flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 3.1 page no. 08 (Group A) | Each | 128.0 | 128.0 | 10.0 | False | None | None | False | None | False | 1280.0 | 0 |
2592294 | 80674 | None | code29 | 6A Three Way 5 Pin Socket 3.14.3 page no 10 | Nos | 70.0 | 70.0 | 10.0 | False | None | None | False | None | False | 700.0 | 0 |
2592295 | 80674 | None | code30 | 6Amps SP Switch 3.14.2 page no. 10 | Nos | 70.0 | 70.0 | 10.0 | False | None | None | False | None | False | 700.0 | 0 |
2592296 | 80674 | None | code31 | 6A Three Pin Top 3.14.4 page no. 10 | No | 87.0 | 87.0 | 10.0 | False | None | None | False | None | False | 870.0 | 0 |
2592297 | 80674 | None | code32 | 6A Bakelite Ceiling Rose 3.14.5 page no. 10 | No | 78.0 | 78.0 | 5.0 | False | None | None | False | None | False | 390.0 | 0 |
2592298 | 80674 | None | code33 | 6A Batten Holder 3.14.7 page no 10 | No | 74.0 | 74.0 | 5.0 | False | None | None | False | None | False | 370.0 | 0 |
2592299 | 80674 | None | code34 | 16A Three Pin Top 3.14.13 page no 10 | No | 110.0 | 110.0 | 5.0 | False | None | None | False | None | False | 550.0 | 0 |
2592300 | 80674 | None | code35 | 32A Bakelite DP 3.14.14 page no. 10 | No. | 232.0 | 232.0 | 2.0 | False | None | None | False | None | False | 464.0 | 0 |
2592301 | 80674 | None | code36 | 16/6A combined plug and socket with control switch 3.14.15 page no. 10 | No. | 218.0 | 218.0 | 2.0 | False | None | None | False | None | False | 436.0 | 0 |
2592302 | 80674 | None | code37 | Electronic stepped regulator. 3.14.16 page no. 10 | Nos | 281.0 | 281.0 | 3.0 | False | None | None | False | None | False | 843.0 | 0 |
2592303 | 80674 | None | code38 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:2010 2.3 page no. 05 (1 mm2 (2.3.1 page no. 05)) | Mtr | 19.0 | 19.0 | 14.3 | False | None | None | False | None | False | 271.7 | 0 |
2592304 | 80674 | None | code39 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:2010 2.3 page no. 05 (1.5 mm2 (2.3.2 page no. 05)) | Mtr | 26.0 | 26.0 | 11.24 | False | None | None | False | None | False | 292.24 | 0 |
2592305 | 80674 | None | code40 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:2010 2.3 page no. 05 (2.5 mm2 (2.3.3 page no. 05)) | Mtr | 42.0 | 42.0 | 20.0 | False | None | None | False | None | False | 840.0 | 0 |
2592306 | 80674 | None | code41 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:2010 2.3 page no. 05 (Sag) | Mtr | 42.0 | 42.0 | 10.0 | False | None | None | False | None | False | 420.0 | 0 |
2592307 | 80674 | None | code42 | Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 5.17.3 page No. 17 (12 Way) | Each | 15529.0 | 15529.0 | 1.0 | False | None | None | False | None | False | 15529.0 | 0 |