2591081 | 80592 | None | code01 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. (PWD SR Vol-2 2023-24; P.No. 187; Serial NO.19.7.3) | Cum | 1080.45 | 1080.45 | 2.59 | False | None | None | False | None | False | 2798.3655 | 0 |
2591082 | 80592 | None | code02 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. (PWD SR Vol-2 2023-24; P.No. 13; Serial NO.6.7) | Cum | 8621.55 | 8621.55 | 15.11 | False | None | None | False | None | False | 130271.6205 | 0 |
2591083 | 80592 | None | code03 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD SR Vol-2 2023-24; P.No. 41; Serial NO.8.1.2) | Sqm | 253.05 | 253.05 | 237.98 | False | None | None | False | None | False | 60220.839 | 0 |
2591084 | 80592 | None | code04 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. as per specifications and as per directions of Engineer in charge. (PWD SR Vol-2 2023-24; P.No. 51; Serial NO.8.60) | Sqm | 17.85 | 17.85 | 349.3 | False | None | None | False | None | False | 6235.005 | 0 |
2591085 | 80592 | None | code05 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR Vol-2 2023-24; P.No. 45; Serial NO.8.27) | Sqm | 55.65 | 55.65 | 587.28 | False | None | None | False | None | False | 32682.132 | 0 |
2591086 | 80592 | None | code06 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge (PWD SR Vol-2 2023-24; P.No. 48; Serial NO.8.39) | Sqm | 133.35 | 133.35 | 587.28 | False | None | None | False | None | False | 78313.788 | 0 |
2591087 | 80592 | None | code07 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (PWD SR Vol-2 2023-24; P.No. 100; Serial NO.12.13.1) | Cum | 103755.75 | 103755.75 | 0.34 | False | None | None | False | None | False | 35276.955 | 0 |
2591088 | 80592 | None | code08 | Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with , stiles and rails of 30mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) (PWD SR Vol-2 2023-24; P.No. 100; Serial NO.12.21) | Sqm | 6029.1 | 6029.1 | 14.4 | False | None | None | False | None | False | 86819.04 | 0 |
2591089 | 80592 | None | code09 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge. (PWD SR Vol-2 2023-24; P.No. 218; Serial NO.22.15) | Nos | 472.5 | 472.5 | 9.0 | False | None | None | False | None | False | 4252.5 | 0 |
2591090 | 80592 | None | code10 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge. (PWD SR Vol-2 2023-24; P.No. 218; Serial NO.22.15)
SS hinges 100 mm | Nos | 73.5 | 73.5 | 24.0 | False | None | None | False | None | False | 1764.0 | 0 |
2591091 | 80592 | None | code11 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge. (PWD SR Vol-2 2023-24; P.No. 218; Serial NO.22.15)
SS Tower Bolts 150x10mm | Nos | 126.0 | 126.0 | 9.0 | False | None | None | False | None | False | 1134.0 | 0 |
2591092 | 80592 | None | code12 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge. (PWD SR Vol-2 2023-24; P.No. 218; Serial NO.22.15)
SS Aldrop 16mm dia, 200mm | Nos | 315.0 | 315.0 | 9.0 | False | None | None | False | None | False | 2835.0 | 0 |
2591093 | 80592 | None | code13 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-incharge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. (PWD SR Vol-2 2023-24; P.No. 87; Serial NO.11.35.1.2) | Kg | 513.45 | 513.45 | 110.77 | False | None | None | False | None | False | 56874.8565 | 0 |
2591094 | 80592 | None | code14 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shuttersand partition frames with C.P. brass / stainless steel screws etc. completeas per architectural drawings and directions of engineer- in-charge:Pre-laminated particle board with decorative lamination on both sides including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (PWD SR Vol-2 2023-24; P.No. 87; Serial NO.11.36.2) | Sqm | 1032.15 | 1032.15 | 34.0 | False | None | None | False | None | False | 35093.1 | 0 |
2591095 | 80592 | None | code15 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :(PWD SR Vol-2 2023-24; P.No. 131; Serial NO.14.2.1) W.C. pan with ISI marked white solid plastic seat and lid | Nos | 5079.9 | 5079.9 | 2.0 | False | None | None | False | None | False | 10159.8 | 0 |
2591096 | 80592 | None | code16 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :(PWD SR Vol-2 2023-24; P.No. 131; Serial NO.14.1) White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests | Nos | 5128.2 | 5128.2 | 2.0 | False | None | None | False | None | False | 10256.4 | 0 |
2591097 | 80592 | None | code17 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required ::(PWD SR Vol-2 2023-24; P.No. 131; Serial NO.14.4.1) One urinal basin with 5 litre white P.V.C. automatic flushing cistern | Nos | 4676.7 | 4676.7 | 6.0 | False | None | None | False | None | False | 28060.2 | 0 |
2591098 | 80592 | None | code18 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:(PWD SR Vol-2 2023-24; P.No. 132; Serial NO.14.7.1) White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps | Nos | 3236.1 | 3236.1 | 3.0 | False | None | None | False | None | False | 9708.3 | 0 |
2591099 | 80592 | None | code19 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (PWD SR Vol-2 2023-24; P.No. 136; Serial NO.14.31) | Nos | 1281.0 | 1281.0 | 3.0 | False | None | None | False | None | False | 3843.0 | 0 |
2591100 | 80592 | None | code20 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. (PWD SR Vol-2 2023-24; P.No. 122; Serial NO.13.32.2) 20 mm nominal dia pipes | m | 397.95 | 397.95 | 62.0 | False | None | None | False | None | False | 24672.9 | 0 |
2591101 | 80592 | None | code21 | Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately. (PWD SR Vol-2 2023-24; P.No. 123; Serial NO.13.34A) | l | 9.45 | 9.45 | 5000.0 | False | None | None | False | None | False | 47250.0 | 0 |
2591102 | 80592 | None | code22 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work (PWD SR Vol-2 2023-24; P.No. 125; Serial NO.13.50.6) 50 mm nominal dia Pipes | m | 405.3 | 405.3 | 72.0 | False | None | None | False | None | False | 29181.6 | 0 |
2591103 | 80592 | None | code23 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 g. (PWD SR Vol-2 2023-24; P.No. 119; Serial NO.13.13) | Nos | 888.3 | 888.3 | 10.0 | False | None | None | False | None | False | 8883.0 | 0 |
2591104 | 80592 | None | code24 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. (PWD SR Vol-2 2023-24; P.No. 69; Serial NO.10.1.2) | Sqm | 4133.85 | 4133.85 | 40.5 | False | None | None | False | None | False | 167420.925 | 0 |
2591105 | 80592 | None | code25 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (PWD SR Vol-2 2023-24; P.No. 77; Serial NO.11.5.2) | Sqm | 4454.1 | 4454.1 | 16.2 | False | None | None | False | None | False | 72156.42 | 0 |
2591106 | 80592 | None | code26 | Brass cupboard lock 6 levers (best make of approved quality) 40 mm size (PWD SR Vol-2 2023-24; P.No. A-14) | Nos | 157.5 | 157.5 | 60.0 | False | None | None | False | None | False | 9450.0 | 0 |
2591107 | 80592 | None | code27 | Providing and fixing Three seater Sofa with cushion of size 7(L)x2.5(W) X2.75(H) ft made of upholstery fabric with seats fitted with padding, springs, webbing and as per direction of engineer in charge. (PWD SR Vol-2 2023-24; P.No. 219; Serial NO. 22.16) | Nos | 39375.0 | 39375.0 | 5.0 | False | None | None | False | None | False | 196875.0 | 0 |
2591108 | 80592 | None | code28 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. (PWD SR Vol-1 2023-24; P.No. 15; Serial NO. 2.1.3) Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6288.45 | 6288.45 | 7.5 | False | None | None | False | None | False | 47163.375 | 0 |
2591109 | 80592 | None | code29 | Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications. (PWD SR Vol-2 2023-24; P.No. 64; Serial NO. 9.34) | Sqm | 1622.25 | 1622.25 | 50.0 | False | None | None | False | None | False | 81112.5 | 0 |
2591110 | 80592 | None | code30 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (PWD SR Vol-1 2023-24; P.No. 15; Serial NO. 2.3) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - Beam @ Entrance | Cum | 6639.15 | 6639.15 | 0.28 | False | None | None | False | None | False | 1858.962 | 0 |
2591111 | 80592 | None | code31 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. (All other type of structures) [SR 2023-24 Vol-1 P.No:18 Sl.No:2.11.H] Beam @ Entrance | MT | 82961.55 | 82961.55 | 0.014 | False | None | None | False | None | False | 1161.4617 | 0 |
2591112 | 80592 | None | code32 | Providing and fixing 1 mm thick M.S. sheet sliding-shutters, with frame and diagonal braces of 40x40x6 mm angle iron, 3 mm M.S. gusset plates at the junctions and corners, 25 mm dia pulley, 40x40x6 mm angle and T- iron guide at the top and bottom respectively, including applying a priming coat of approved steel primer including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (PWD SR Vol-2 2023-24; P.No. 77; Serial NO. 11.4) | Sqm | 5482.05 | 5482.05 | 12.0 | False | None | None | False | None | False | 65784.6 | 0 |
2591113 | 80592 | None | code33 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg/m2, including pointing in white cement mixed with pigment of matching shade complete. (PWD SR Vol-2 2023-24; P.No. 70; Serial NO. 10.14) Wall Tiles | Sqm | 1161.3 | 1161.3 | 8.0 | False | None | None | False | None | False | 9290.4 | 0 |
2591114 | 80592 | None | code34 | Plastic chair (Cello/Nilkamal/Lavanya) [As per Market rate approval by SE Dt:01.01.2024] | No | 790.0 | 790.0 | 20.0 | False | None | None | False | None | False | 15800.0 | 0 |
2591115 | 80592 | None | code35 | Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thickconfirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. Page No. 02 1.1.4 (I - Point wiring using class A materials.) | Mtr | 149.0 | 149.0 | 307.28 | False | None | None | False | None | False | 45784.72 | 0 |
2591116 | 80592 | None | code36 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc 1.4.7 Page No. 02 (200x200x65mm) | Each | 348.0 | 348.0 | 15.0 | False | None | None | False | None | False | 5220.0 | 0 |
2591117 | 80592 | None | code37 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete 1.4.7 Page No. 03 (12" x 12" x 3" (300 x 300 x 76 mm)) | Each | 120.0 | 120.0 | 10.0 | False | None | None | False | None | False | 1200.0 | 0 |
2591118 | 80592 | None | code38 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete 1.4.7 Page No. 03 (8" x 6" x 3" (203 x 152 x 76 mm)) | Each | 86.0 | 86.0 | 10.0 | False | None | None | False | None | False | 860.0 | 0 |
2591119 | 80592 | None | code39 | Supplying & Fixing of 230 V 20/40 W Fluorescent Lamp holder 12.45 page no. 52 | No | 33.0 | 33.0 | 20.0 | False | None | None | False | None | False | 660.0 | 0 |
2591120 | 80592 | None | code40 | Supplying & fixing LED Drivers suitable for 5700K LED fitting Indoor Fixtures. Operating voltage range from 180V to 265V, 50Hz AC power Supply 12.51 page no. 53 (upto 3W 5700K suitable for indoor LED fitting 12.51.1 page no. 53) | No | 275.0 | 275.0 | 20.0 | False | None | None | False | None | False | 5500.0 | 0 |
2591121 | 80592 | None | code41 | Supplying 6A flush type socket and 6 A flush type SP switch either
surface/flush mounting in existing gang box or in 4mm thick plastic
sheet and fixing over a flush mounted wooden box and wiring using
necessary capacity wires as required as per IS 1293 and IS 3854 3.1 page no. 08 (Group A) | Each | 128.0 | 128.0 | 20.0 | False | None | None | False | None | False | 2560.0 | 0 |
2591122 | 80592 | None | code42 | 6A Three Way 5 Pin Socket 3.14.3 page no 10 | Nos | 70.0 | 70.0 | 20.0 | False | None | None | False | None | False | 1400.0 | 0 |
2591123 | 80592 | None | code43 | 6Amps SP Switch 3.14.2 page no. 10 | Nos | 70.0 | 70.0 | 20.0 | False | None | None | False | None | False | 1400.0 | 0 |
2591124 | 80592 | None | code44 | 6A Three Pin Top 3.14.4 page no. 10 | No | 87.0 | 87.0 | 25.0 | False | None | None | False | None | False | 2175.0 | 0 |
2591125 | 80592 | None | code45 | 6A Bakelite Ceiling Rose 3.14.5 page no. 10 | No | 78.0 | 78.0 | 10.0 | False | None | None | False | None | False | 780.0 | 0 |
2591126 | 80592 | None | code46 | 6A Batten Holder 3.14.7 page no 10 | No | 74.0 | 74.0 | 10.0 | False | None | None | False | None | False | 740.0 | 0 |
2591127 | 80592 | None | code47 | 16A Three Pin Top 3.14.13 page no 10 | No | 110.0 | 110.0 | 10.0 | False | None | None | False | None | False | 1100.0 | 0 |
2591128 | 80592 | None | code48 | 32A Bakelite DP 3.14.14 page no. 10 | No. | 232.0 | 232.0 | 2.0 | False | None | None | False | None | False | 464.0 | 0 |
2591129 | 80592 | None | code49 | 16/6A combined plug and socket with control switch 3.14.15 page no. 10 | No. | 218.0 | 218.0 | 2.0 | False | None | None | False | None | False | 436.0 | 0 |
2591130 | 80592 | None | code50 | Electronic stepped regulator. 3.14.16 page no. 10 | Nos | 281.0 | 281.0 | 5.0 | False | None | None | False | None | False | 1405.0 | 0 |
2591131 | 80592 | None | code51 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:2010 2.3 page no. 05 (1 mm2 (2.3.1 page no. 05) ) | Mtr | 19.0 | 19.0 | 153.28 | False | None | None | False | None | False | 2912.32 | 0 |
2591132 | 80592 | None | code52 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:2010 2.3 page no. 05 1.5 mm2 (2.3.2 page no. 05) | Mtr | 26.0 | 26.0 | 143.56 | False | None | None | False | None | False | 3732.56 | 0 |
2591133 | 80592 | None | code53 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:2010 2.3 page no. 05 2.5 mm2 (2.3.3 page no. 05) | Mtr | 42.0 | 42.0 | 144.0 | False | None | None | False | None | False | 6048.0 | 0 |
2591134 | 80592 | None | code54 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:2010 2.3 page no. 05 Sag | Mtr | 42.0 | 42.0 | 10.0 | False | None | None | False | None | False | 420.0 | 0 |
2591135 | 80592 | None | code55 | 3x95 + 1x70 + 1x16 Sqmm Street light (Insulated Messenger cum Neutral | Km | 494091.0 | 494091.0 | 0.16 | False | None | None | False | None | False | 79054.56 | 0 |
2591136 | 80592 | None | code56 | Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 5.17.3 page No. 17 (12 Way) | Each | 15529.0 | 15529.0 | 1.0 | False | None | None | False | None | False | 15529.0 | 0 |
2591137 | 80592 | None | code57 | Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 3 kVA ON LINE UPS [PWD Ele SR 2-23-24 P.No:38 Sl.No.9.3.2] | Each | 38719.0 | 38719.0 | 1.0 | False | None | None | False | None | False | 38719.0 | 0 |
2591138 | 80592 | None | code58 | Supplying, installation, testing & commissioning of 12VDC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 150 AH capacity [PWD Ele SR 2-23-24 P.No:39 Sl.No.9.5.9] | Each | 15895.0 | 15895.0 | 3.0 | False | None | None | False | None | False | 47685.0 | 0 |
2591139 | 80592 | None | code59 | SPECIFICATIONS OF OUR CONCRETE DECK OF 60 MT- 9X3m PLATFORM
Steel supporting structure with I beams., Truck Scale Software, Civil Electrical and Earthing Drawings, Depute our Engineers for supervising the installation and commissioning of the Weigh Bridge., Digital Indicator : 1 No, Load Cells with Assembly Kit ( DESB ) : 6 No’s, Junction Box : 1 No, ESPD (Surge Protection Devise) : 1 No, Cable and connectors : As Required, Additional Display : 1 No, Weighbridge Civil foundation Pit Less Type for Concrete Weigh Bridge, GI Earthing, Unloading, Installation, Cable conduit Laying and Stamping [As per Market rate approval by SE Dt:01.01.2024] | Job | 1531640.0 | 1531640.0 | 1.0 | False | None | None | False | None | False | 1531640.0 | 0 |