2590408 | 80565 | None | code01 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) (UNI SR Volume-1) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates -- PAGE 17 -- 2.5.2 | Cum | 11465.25 | 11465.25 | 17.8 | False | None | None | False | None | False | 204081.45 | 0 |
2590409 | 80565 | None | code02 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) (UNI SR Volume-1) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates -- PAGE 17 -- 2.5.2 | Cum | 11465.25 | 11465.25 | 1.73 | False | None | None | False | None | False | 19834.8825 | 0 |
2590410 | 80565 | None | code03 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. -- PAGE 17 -- 2.5.2 | Sqm | 1362.79 | 1362.79 | 259.42 | False | None | None | False | None | False | 353534.9818 | 0 |
2590411 | 80565 | None | code04 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.-- PAGE 17 -- 2.5.2 | Sqm | 1280.61 | 1280.61 | 91.98 | False | None | None | False | None | False | 117790.5078 | 0 |
2590412 | 80565 | None | code05 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) (UNI SR Volume-1) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-- PAGE 17 -- 2.5.1 | Cum | 11035.5 | 11035.5 | 2.1 | False | None | None | False | None | False | 23174.55 | 0 |
2590413 | 80565 | None | code06 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) (UNI SR Volume-1) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates -- PAGE 16 -- 2.3.2 | Cum | 9956.92 | 9956.92 | 4.75 | False | None | None | False | None | False | 47295.37 | 0 |
2590414 | 80565 | None | code07 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) (UNI SR Volume-1) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates -- PAGE 17 -- 2.5.1 | Cum | 10000.92 | 10000.92 | 4.86 | False | None | None | False | None | False | 48604.4712 | 0 |
2590415 | 80565 | None | code08 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) (UNI SR Volume-1) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10000.92 | 10000.92 | 0.33 | False | None | None | False | None | False | 3300.3036 | 0 |
2590416 | 80565 | None | code09 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) (UNI SR Volume-1) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10289.82 | 10289.82 | 11.28 | False | None | None | False | None | False | 116069.1696 | 0 |
2590417 | 80565 | None | code10 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) (UNI SR Volume-1) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates -- PAGE 16 -- 2.5.2 | Cum | 10322.22 | 10322.22 | 3.4779 | False | None | None | False | None | False | 35899.648938 | 0 |
2590418 | 80565 | None | code11 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) (UNI SR Volume-1) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates -- PAGE 17 -- 2.5.2 | Cum | 10678.16 | 10678.16 | 39.42 | False | None | None | False | None | False | 420933.0672 | 0 |
2590419 | 80565 | None | code12 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. --- PAGE --133--15.1 | Sqm | 849.93 | 849.93 | 397.0 | False | None | None | False | None | False | 337422.21 | 0 |
2590420 | 80565 | None | code13 | Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. --Sl.No 12.13.2, Page No.100 -- Volume- II | Cum | 103613.88 | 103613.88 | 1.39 | False | None | None | False | None | False | 144023.2932 | 0 |
2590421 | 80565 | None | code14 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-35 mm thick both side commercial -- Sl. No. 12.57.6 Page No. 106, Volume-II | Sqm | 3455.88 | 3455.88 | 28.8 | False | None | None | False | None | False | 99529.344 | 0 |
2590422 | 80565 | None | code15 | Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. Sl.No 12.13.2, Page No.100--Volume- II | Cum | 103613.88 | 103613.88 | 0.59 | False | None | None | False | None | False | 61132.1892 | 0 |
2590423 | 80565 | None | code16 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. 35 mm thick both side commercial -- PAGE-106-12.57.6 | Sqm | 3455.88 | 3455.88 | 9.0 | False | None | None | False | None | False | 31102.92 | 0 |
2590424 | 80565 | None | code17 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. --- 12.51 | Nos | 1046.48 | 1046.48 | 2.0 | False | None | None | False | None | False | 2092.96 | 0 |
2590425 | 80565 | None | code18 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding -- PAGE-85--11.34A | Kg | 174.77 | 174.77 | 648.0 | False | None | None | False | None | False | 113250.96 | 0 |
2590426 | 80565 | None | code19 | Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) - PAGE-111-12.89 | Sqm | 6815.01 | 6815.01 | 24.75 | False | None | None | False | None | False | 168671.4975 | 0 |
2590427 | 80565 | None | code20 | Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) - PAGE-111-12.89 | Sqm | 6815.01 | 6815.01 | 4.5 | False | None | None | False | None | False | 30667.545 | 0 |
2590428 | 80565 | None | code21 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. PAGE-83-11.28 | Kg | 581.95 | 581.95 | 112.7 | False | None | None | False | None | False | 65585.765 | 0 |
2590429 | 80565 | None | code22 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding -- PAGE-85--11.34A | Sqm | 173.04 | 173.04 | 34.83 | False | None | None | False | None | False | 6026.9832 | 0 |
2590430 | 80565 | None | code23 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. -- vol -II- 42 -- 8.2.1 | Sqm | 306.89 | 306.89 | 430.63 | False | None | None | False | None | False | 132156.0407 | 0 |
2590431 | 80565 | None | code24 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. -- vol -II- 50 -- 8.51 | Sqm | 104.03 | 104.03 | 430.63 | False | None | None | False | None | False | 44798.4389 | 0 |
2590432 | 80565 | None | code25 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. -- vol -II- 42 -- 8.2.1 | Sqm | 306.89 | 306.89 | 621.41 | False | None | None | False | None | False | 190704.5149 | 0 |
2590433 | 80565 | None | code26 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. -- vol -II- 41 -- 8.4.1 | Sqm | 336.02 | 336.02 | 149.83 | False | None | None | False | None | False | 50345.8766 | 0 |
2590434 | 80565 | None | code27 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. -- vol -II- 50 -- 8.51 | Sqm | 104.03 | 104.03 | 149.83 | False | None | None | False | None | False | 15586.8149 | 0 |
2590435 | 80565 | None | code28 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.
Size of Tile 600x600 mm --- PAGE - 61 --- 9.17.2 | Sqm | 1222.35 | 1222.35 | 18.86 | False | None | None | False | None | False | 23053.521 | 0 |
2590436 | 80565 | None | code29 | Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. -- vol -II- 70 -- 10.8 | Sqm | 2901.4 | 2901.4 | 7.72 | False | None | None | False | None | False | 22398.808 | 0 |
2590437 | 80565 | None | code30 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. -- vol -II- 63 -- 9.24 | Sqm | 2966.94 | 2966.94 | 20.93 | False | None | None | False | None | False | 62098.0542 | 0 |
2590438 | 80565 | None | code31 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. | Sqm | 924.83 | 924.83 | 38.25 | False | None | None | False | None | False | 35374.7475 | 0 |
2590439 | 80565 | None | code32 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. | Sqm | 1507.39 | 1507.39 | 70.95 | False | None | None | False | None | False | 106949.3205 | 0 |
2590440 | 80565 | None | code33 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. -- vol -II- 46 -- 8.33.1 | Sqm | 164.37 | 164.37 | 228.71 | False | None | None | False | None | False | 37593.0627 | 0 |
2590441 | 80565 | None | code34 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 185.17 | 185.17 | 621.41 | False | None | None | False | None | False | 115066.4897 | 0 |
2590442 | 80565 | None | code35 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. -- PAGE--46--8.33.2 | Sqm | 143.56 | 143.56 | 60.84 | False | None | None | False | None | False | 8734.1904 | 0 |
2590443 | 80565 | None | code36 | Finishing with Epoxy paint (two coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Enginer-in-charge. -- vol -II- 47 -- 8.36.1 | Sqm | 183.09 | 183.09 | 106.11 | False | None | None | False | None | False | 19427.6799 | 0 |
2590444 | 80565 | None | code37 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. PAGE-48--8.40 | Sqm | 119.63 | 119.63 | 66.6 | False | None | None | False | None | False | 7967.358 | 0 |
2590445 | 80565 | None | code38 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. -- vol -II- 63 -- 9.24 | Sqm | 2966.94 | 2966.94 | 36.83 | False | None | None | False | None | False | 109272.4002 | 0 |
2590446 | 80565 | None | code39 | Providing and laying flooring with burnt stone slabs 10 cms thick rough chistle dressed on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3, , including cost of materials, mortar, labour, curing complete as per specifications. -- 9.27 | Sqm | 2459.64 | 2459.64 | 22.49 | False | None | None | False | None | False | 55317.3036 | 0 |
2590447 | 80565 | None | code40 | Providing Thermo-Mechanically Treated bars of grade Fe-550D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) -- vol -II- 84 -- 11.32 | Kg | 93.07 | 93.07 | 10980.63 | False | None | None | False | None | False | 1021967.2341 | 0 |
2590448 | 80565 | None | code41 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. -- 7.18 | Cum | 2077.51 | 2077.51 | 14.4 | False | None | None | False | None | False | 29916.144 | 0 |
2590449 | 80565 | None | code42 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. -- vol -II- 17 -- 6.32 | Sqm | 1349.3 | 1349.3 | 4.86 | False | None | None | False | None | False | 6557.598 | 0 |
2590450 | 80565 | None | code43 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. -- vol -II- 42 -- 8.2.1 | Sqm | 303.85 | 303.85 | 11.61 | False | None | None | False | None | False | 3527.6985 | 0 |
2590451 | 80565 | None | code44 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm -- 14.32.2 | Nos | 1048.54 | 1048.54 | 4.0 | False | None | None | False | None | False | 4194.16 | 0 |
2590452 | 80565 | None | code45 | Providing and placing on terrace (at all floor levels) polyethene water storage tanks, IS : 12701 marked, with cover and suitable locking arrangements, making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. -- PAGE-187 -- 13.34 | Nos | 9.27 | 9.27 | 2000.0 | False | None | None | False | None | False | 18540.0 | 0 |
2590453 | 80565 | None | code46 | Providing and fixing 3 layer PP-R (Poly Propylene Random Copolymer) pipes confirming to IS.15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply, including all PP-R plain and brass threaded polypropylene random fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineer-In- Charge.===Poly Propylene Random Co-ploymer (PPR) pipe with fitting SDR 7.4 -16 mm Outer dia -- Vol 5 Page 34 --2.62.1 | m | 60.77 | 60.77 | 190.0 | False | None | None | False | None | False | 11546.3 | 0 |
2590454 | 80565 | None | code47 | Providing and fixing 3 layer PP-R (Poly Propylene Random Copolymer) pipes confirming to IS.15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply, including all PP-R plain and brass threaded polypropylene random fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineer-In- Charge. Poly Propylene Random Co-ploymer (PPR) pipe with fitting SDR 7.4 -20 mm Outer dia -- Vol 5 Page 34 --2.62.2 | m | 172.01 | 172.01 | 205.0 | False | None | None | False | None | False | 35262.05 | 0 |
2590455 | 80565 | None | code48 | Providing and fixing 3 layer PP-R (Poly Propylene Random Copolymer) pipes confirming to IS.15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply, including all PP-R plain and brass threaded polypropylene random fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineer-In- Charge.---32mm nominal dia Pipes -- Vol 5 Page 34 --2.62.4 | m | 155.53 | 155.53 | 345.0 | False | None | None | False | None | False | 53657.85 | 0 |
2590456 | 80565 | None | code49 | Providing and fixing 3 layer PP-R (Poly Propylene Random Copolymer) pipes confirming to IS.15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply, including all PP-R plain and brass threaded polypropylene random fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineer-In- Charge. === 40mm nominal dia Pipes -- Vol 5 Page 34 --2.62.5 | m | 250.29 | 250.29 | 502.0 | False | None | None | False | None | False | 125645.58 | 0 |
2590457 | 80565 | None | code50 | Providing and fixing brass bib cock of approved quality : 15MM == Vol 2 Page 114 == 13.2.1 | Nos | 294.58 | 294.58 | 25.0 | False | None | None | False | None | False | 7364.5 | 0 |
2590458 | 80565 | None | code51 | Providing and fixing brass stop cock of approved quality : 15MM--- Vol 2 Page 114 -- 13.3.1 | Nos | 307.97 | 307.97 | 2.0 | False | None | None | False | None | False | 615.94 | 0 |
2590459 | 80565 | None | code52 | Providing and fixing unplasticised PVC connection pipe with brass unions : Vol 2 - 123 -- 13.8.1 | Nos | 85.49 | 85.49 | 6.0 | False | None | None | False | None | False | 512.94 | 0 |
2590460 | 80565 | None | code53 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: (Urinal Ladies) Vol 2 - 188--14.1.2 | Each | 9070.18 | 9070.18 | 6.0 | False | None | None | False | None | False | 54421.08 | 0 |
2590461 | 80565 | None | code54 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. --Vol 2 - 128--14.40.2 | Nos | 510.88 | 510.88 | 6.0 | False | None | None | False | None | False | 3065.28 | 0 |
2590462 | 80565 | None | code55 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete Vol 2 - 115 --13.4.1 ---25mm dia | Nos | 565.47 | 565.47 | 2.0 | False | None | None | False | None | False | 1130.94 | 0 |
2590463 | 80565 | None | code56 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete Vol 2 - 115 --13.4.3 --- 40mm | Nos | 723.06 | 723.06 | 2.0 | False | None | None | False | None | False | 1446.12 | 0 |
2590464 | 80565 | None | code57 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: -- Vol 5 Page 134 -- 10.1.2--PVC pipes 32mm dia., 10 kg/sqcm & class 5 | m | 65.92 | 65.92 | 67.0 | False | None | None | False | None | False | 4416.64 | 0 |
2590465 | 80565 | None | code58 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: -- Vol 5 Page 134 -- 10.1.5 -- PVC pipes 75mm dia., 6 kg/sqcm & class 3 | m | 226.6 | 226.6 | 42.0 | False | None | None | False | None | False | 9517.2 | 0 |
2590466 | 80565 | None | code59 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: -- Vol 5 Page 134 -- 10.1.7 -- PVC pipes 110mm dia., 6 kg/sqcm & class 3 | m | 423.33 | 423.33 | 176.0 | False | None | None | False | None | False | 74506.08 | 0 |
2590467 | 80565 | None | code60 | Earth work excavation for pipelines/cables by mechanical means upto 600mm trench width, as per drawing and technical specifcations, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. (Vol.1, P 10, I 1.17.1) --Soft Rock9 95% (with blasting) (Vol.1, P8, I 1.116.1) | Cum | 431.57 | 431.57 | 202.5 | False | None | None | False | None | False | 87392.925 | 0 |
2590468 | 80565 | None | code61 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00m spacing. This included jointing of pipes & fittinfs with one step CPVC solvent cement and testing of joints complete as per direction of Enginner in Charge.---15 mm nominal dia Pipes (Vol. 2, I 13.31.1) | m | 185.4 | 185.4 | 250.0 | False | None | None | False | None | False | 46350.0 | 0 |
2590469 | 80565 | None | code62 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00m spacing. This included jointing of pipes & fittinfs with one step CPVC solvent cement and testing of joints complete as per direction of Enginner in Charge.---25 mm nominal dia Pipes (Vol. 2, I 13.31.3) | m | 325.48 | 325.48 | 250.0 | False | None | None | False | None | False | 81370.0 | 0 |
2590470 | 80565 | None | code63 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00m spacing. This included jointing of pipes & fittinfs with one step CPVC solvent cement and testing of joints complete as per direction of Enginner in Charge.---32 mm nominal dia Pipes (Vol. 2, I 13.31.4) | m | 404.79 | 404.79 | 150.0 | False | None | None | False | None | False | 60718.5 | 0 |
2590471 | 80565 | None | code64 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00m spacing. This included jointing of pipes & fittinfs with one step CPVC solvent cement and testing of joints complete as per direction of Enginner in Charge.---50 mm nominal dia Pipes (Vol. 2, I 13.31.6) | m | 790.01 | 790.01 | 150.0 | False | None | None | False | None | False | 118501.5 | 0 |
2590472 | 80565 | None | code65 | Providing GM (copper alloy) wheel valves/ check valve confrming to IS 778/1990 Class-I with latest amendments No. 1 and with ISI mark screwed in bonnet integral seat inside, screw, rising spindle screwed female ends confrming to IS 554/ 1990 body hudraulically tested 1.50 HP seat hydraulically tested 1.00 HP. --For 15 mm dia GM (Copper alloy) wheel valves/ check valve. (Vol. 5, P 147, I N200A) | Each | 586.07 | 586.07 | 20.0 | False | None | None | False | None | False | 11721.4 | 0 |
2590473 | 80565 | None | code66 | Supply and delivery at site GM (copper alloy) gate valves confrming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confrming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. --For 50 mm dia GM (Copper alloy) Gate valves (Vol. 5, P 147, I N180F) | Each | 1738.64 | 1738.64 | 8.0 | False | None | None | False | None | False | 13909.12 | 0 |
2590474 | 80565 | None | code67 | Providing and fixing PTMT pillar cock of approved quality and color. 15 mm nominal bore, 125 mm long foam flow, weighing not less than 120 mms. | Each | 226.6 | 226.6 | 62.0 | False | None | None | False | None | False | 14049.2 | 0 |
2590475 | 80565 | None | code68 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. | Each | 4373.38 | 4373.38 | 15.0 | False | None | None | False | None | False | 65600.7 | 0 |
2590476 | 80565 | None | code69 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and
lid, 10 liter low level white vitreous china fishing cistern & C.P. fuss bend with fittings & C.I. brackets, 40 mm fush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and fours wherever required : W.C. pan with ISI marked white solid plastic seat and lid. (Vol. 2, P 123, I 14.3.1) | Each | 5155.15 | 5155.15 | 3.0 | False | None | None | False | None | False | 15465.45 | 0 |
2590477 | 80565 | None | code70 | Providing and fxing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fttings and brackets, cutting and making good the walls wherever require: White Vitreous China Angle back wash basin size 600 x 480 mm with single 15mm C.P. brass pillar tap.(Vol. 2, P 125, I 14.7.5) | Each | 2220.68 | 2220.68 | 14.0 | False | None | None | False | None | False | 31089.52 | 0 |
2590478 | 80565 | None | code71 | Providing and fixing CI Nahni trap of approved make conforming to ISI specifications and construction of cistern in CC 1:2:4 as per directions (Rate is inclusive of cost materials and fixtures and conveyance of materials to work spot) 10cmsx7.5cms ( Vol2. P128. I 14.29.) | Each | 211.15 | 211.15 | 20.0 | False | None | None | False | None | False | 4223.0 | 0 |
2590479 | 80565 | None | code72 | Providing and fixing 100 mm sand cast Iron grating for gully trap (Vol. 2, P 128, I 14.29) | Each | 211.15 | 211.15 | 20.0 | False | None | None | False | None | False | 4223.0 | 0 |
2590480 | 80565 | None | code73 | Providing and fxing PTMT towel rail complete with brackets fxed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. (Vol. 2, P 13, I 14.40.2) | Each | 391.4 | 391.4 | 20.0 | False | None | None | False | None | False | 7828.0 | 0 |
2590481 | 80565 | None | code74 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (Vol.2, P 128, I 14.31) | Each | 1000.13 | 1000.13 | 20.0 | False | None | None | False | None | False | 20002.6 | 0 |
2590482 | 80565 | None | code75 | Lowering, laying and fusion welding Jointing for HDPE Pipes Grade PE-80 / PE-100 conforming to IS 4984-2016, of specifed dia. including hydrualic testing and commissioning etc.(Contractor will make his own arrangements for procuring water for testing) for: 110mm dia. (Vol.5, P 121, I ). For Grade PE80 PN6.0 :-- Ground, First & Second Floor 75mm | m | 189.52 | 189.52 | 100.0 | False | None | None | False | None | False | 18952.0 | 0 |
2590483 | 80565 | None | code76 | Lowering, laying and fusion welding Jointing for HDPE Pipes Grade PE-80 / PE-100 conforming to IS 4984-2016, of specifed dia. including hydrualic testing and commissioning etc.(Contractor will make his own arrangements for procuring water for testing) for: 110mm dia. (Vol.5, P 121, I ). For Grade PE80 PN6.0 :---Ground, First & Second Floor | m | 699.37 | 699.37 | 100.0 | False | None | None | False | None | False | 69937.0 | 0 |
2590484 | 80565 | None | code77 | Lowering, laying and fusion welding Jointing for HDPE Pipes Grade PE-80 / PE-100 conforming to IS 4984-2016, of specifed dia. including hydrualic testing and commissioning etc.(Contractor will make his own arrangements for procuring water for testing) for: 110mm dia. (Vol.5, P 121, I ). For Grade PE80 PN6.0 :---Ground, First & Second Floor | m | 358.44 | 358.44 | 100.0 | False | None | None | False | None | False | 35844.0 | 0 |
2590485 | 80565 | None | code78 | Providing and fxing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fttings of approved quality and colour, weighing not less than 105 gms. (Vol. 2, P 129, I 14.38) | Each | 119.48 | 119.48 | 27.0 | False | None | None | False | None | False | 3225.96 | 0 |
2590486 | 80565 | None | code79 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arranfement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support tank. (Vol. 2, I 13.34) | Ltr | 8.24 | 8.24 | 8000.0 | False | None | None | False | None | False | 65920.0 | 0 |
2590487 | 80565 | None | code80 | Supplying, installation, testing and commissioning of solar hot water heater comprising of high quality Evacuated Glass Tube (EGT) with absorber coating collector of size 58 x 1800 mm. Inner tank Material-Stainless steel 304-L Grade with Aluminium Stucco cladding made of High quality PUF insulation to minimizes heat loss and hold water Temperature upto 72 Hrs...with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. Fitted with Sacrificial Anode. --200 L- 20 nos Tubes (Vol.6, P 27, I 7.4.2) | Each | 42342.27 | 42342.27 | 2.0 | False | None | None | False | None | False | 84684.54 | 0 |
2590488 | 80565 | None | code81 | Supplying, installation, testing and commissioning of solar hot water heater comprising of high quality Evacuated Glass Tube (EGT) with absorber coating collector of size 58 x 1800 mm. Inner tank Material-Stainless steel 304-L Grade with Aluminium Stucco cladding made of High quality PUF insulation to minimizes heat loss and hold water Temperature upto 72 Hrs...with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. Fitted with Sacrificial Anode. --300 L- 29 nos Tubes (Vol.6, P 27, I 7.4.3) | Each | 54995.82 | 54995.82 | 2.0 | False | None | None | False | None | False | 109991.64 | 0 |
2590489 | 80565 | None | code82 | Providing & fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology. P.119. I13.30) | Nos | 7596.25 | 7596.25 | 3.0 | False | None | None | False | None | False | 22788.75 | 0 |
2590490 | 80565 | None | code83 | Internal Wiring - Point wiring using Copper wire with switch Supplying & wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5sqmm (Phase & Neutral) & 1x1.0sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.----Short point upto 3Mtr from tapping point to outlet via switch. -- Page No.--5--Item No. -- 2.2.1 | Nos | 269.0 | 269.0 | 20.0 | False | None | None | False | None | False | 5380.0 | 0 |
2590491 | 80565 | None | code84 | Internal Wiring - Point wiring using Copper wire with switch Supplying & wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5sqmm (Phase & Neutral) & 1x1.0sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.---Medium point above 3Mtr upto 6Mtr from tapping point to outlet via switch. -- Page No.--5--Item No. -- 2.2.2 | Nos | 379.0 | 379.0 | 15.0 | False | None | None | False | None | False | 5685.0 | 0 |
2590492 | 80565 | None | code85 | Internal Wiring - Point wiring using Copper wire with switch Supplying & wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5sqmm (Phase & Neutral) & 1x1.0sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.---Long point above 6Mtr upto 10Mtr from tapping point to outlet via switch. -- Page No.--5--Item No. -- 2.2.3 | Nos | 555.0 | 555.0 | 15.0 | False | None | None | False | None | False | 8325.0 | 0 |
2590493 | 80565 | None | code86 | Internal Wiring - Point wiring using Copper wire with switch Supplying & wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5sqmm (Phase & Neutral) & 1x1.0sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.---Two outlet in a row, above 3 Mtr upto 6 Mtr from tapping point to out let via switches. -- Page No.--5--Item No. -- 2.2.4 | Nos | 677.0 | 677.0 | 2.0 | False | None | None | False | None | False | 1354.0 | 0 |
2590494 | 80565 | None | code87 | Internal Wiring - Point wiring using Copper wire with switch Supplying & wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5sqmm (Phase & Neutral) & 1x1.0sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.---Three outlet in a row, above 6 Mts upto 10 Mtr from tapping point to out let via switches. -- Page No.--5--Item No. -- 2.2.5 | Nos | 989.0 | 989.0 | 3.0 | False | None | None | False | None | False | 2967.0 | 0 |
2590495 | 80565 | None | code88 | Supplying heavy gauge PVC conduit pipe 2mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary.==19/20mm dia 2mm thick -- Page No.--2--Item No. -- 1.2.1 | m | 66.0 | 66.0 | 190.0 | False | None | None | False | None | False | 12540.0 | 0 |
2590496 | 80565 | None | code89 | Supplying heavy gauge PVC conduit pipe 2mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary.----25mm dia 2mm thick -- Page No.--2--Item No. -- 1.2.1 | m | 78.0 | 78.0 | 110.0 | False | None | None | False | None | False | 8580.0 | 0 |
2590497 | 80565 | None | code90 | Supplying heavy gauge PVC conduit pipe 2mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary.---32mm dia 2.5mm thick -- Page No.--2--Item No. -- 1.2.1 | m | 103.0 | 103.0 | 25.0 | False | None | None | False | None | False | 2575.0 | 0 |
2590498 | 80565 | None | code91 | Supplying heavy gauge PVC Conduit Pipe 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.---19/20mm dia 2mm thick -- Page No.--2--Item No. -- 1.3.1 | m | 68.0 | 68.0 | 75.0 | False | None | None | False | None | False | 5100.0 | 0 |
2590499 | 80565 | None | code92 | Supplying heavy gauge PVC Conduit Pipe 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.---25mm dia 2mm thick -- Page No.--2--Item No. -- 1.3.1 | m | 79.0 | 79.0 | 35.0 | False | None | None | False | None | False | 2765.0 | 0 |
2590500 | 80565 | None | code93 | Supplying heavy gauge PVC Conduit Pipe 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.---32mm dia 2.5mm thick -- Page No.--2--Item No. -- 1.3.1 | m | 99.0 | 99.0 | 10.0 | False | None | None | False | None | False | 990.0 | 0 |
2590501 | 80565 | None | code94 | Supplying and fixing PVC/metal conduit Deep junction box--19/20mm deep junction box -- Page No.--2--Item No. -- 1.5.1 | Each | 49.0 | 49.0 | 45.0 | False | None | None | False | None | False | 2205.0 | 0 |
2590502 | 80565 | None | code95 | Supplying and fixing PVC/metal conduit Deep junction box---25mm deep junction box -- Page No.--2--Item No. -- 1.5.1 | Each | 56.0 | 56.0 | 20.0 | False | None | None | False | None | False | 1120.0 | 0 |
2590503 | 80565 | None | code96 | Supplying and fixing PVC/metal conduit Deep junction box---32mm deep junction box -- Page No.--2--Item No. -- 1.5.1 | Each | 61.0 | 61.0 | 5.0 | False | None | None | False | None | False | 305.0 | 0 |
2590504 | 80565 | None | code97 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300mm …. etc. as required. -- 20mm -- Page No.--3--Item No. -- 1.8.1 | m | 28.0 | 28.0 | 45.0 | False | None | None | False | None | False | 1260.0 | 0 |
2590505 | 80565 | None | code98 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300mm …. etc. as required. --- 25mm -- Page No.--3--Item No. -- 1.8.2 | m | 35.0 | 35.0 | 35.0 | False | None | None | False | None | False | 1225.0 | 0 |
2590506 | 80565 | None | code99 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300mm …. etc. as required. --- 32mm -- Page No.--3--Item No. -- 1.8.3 | m | 48.0 | 48.0 | 15.0 | False | None | None | False | None | False | 720.0 | 0 |
2590507 | 80565 | None | code100 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cuttingin Brick/Stone/C.C wall.---1-3Way -- Page No.--8--Item No. -- 3.4.1 | Each | 138.0 | 138.0 | 45.0 | False | None | None | False | None | False | 6210.0 | 0 |
2590508 | 80565 | None | code101 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cuttingin Brick/Stone/C.C wall.---4-5Way -- Page No.--8--Item No. -- 3.4.2 | Each | 177.0 | 177.0 | 20.0 | False | None | None | False | None | False | 3540.0 | 0 |
2590509 | 80565 | None | code102 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cuttingin Brick/Stone/C.C wall.---6Way -- Page No.--8--Item No. -- 3.4.3 | Each | 220.0 | 220.0 | 20.0 | False | None | None | False | None | False | 4400.0 | 0 |
2590510 | 80565 | None | code103 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cuttingin Brick/Stone/C.C wall.--8Way -- Page No.--8--Item No. -- 3.4.4 | Each | 261.0 | 261.0 | 10.0 | False | None | None | False | None | False | 2610.0 | 0 |
2590511 | 80565 | None | code104 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cuttingin Brick/Stone/C.C wall.---10-12Way -- Page No.--8--Item No. -- 3.4.5 | Each | 319.0 | 319.0 | 8.0 | False | None | None | False | None | False | 2552.0 | 0 |
2590512 | 80565 | None | code105 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.---1 to 3 Module -- Page No.--8--Item No. -- 3.5.1 | Each | 137.0 | 137.0 | 45.0 | False | None | None | False | None | False | 6165.0 | 0 |
2590513 | 80565 | None | code106 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.---4 Module -- Page No.--8--Item No. -- 3.5.2 | Each | 175.0 | 175.0 | 20.0 | False | None | None | False | None | False | 3500.0 | 0 |
2590514 | 80565 | None | code107 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.---6 Module -- Page No.--8--Item No. -- 3.5.3 | Each | 234.0 | 234.0 | 20.0 | False | None | None | False | None | False | 4680.0 | 0 |
2590515 | 80565 | None | code108 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.---8 Module -- Page No.--8--Item No. -- 3.5.4 | Each | 284.0 | 284.0 | 10.0 | False | None | None | False | None | False | 2840.0 | 0 |
2590516 | 80565 | None | code109 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.---10 -12 Module -- Page No.--8--Item No. -- 3.5.5 | Each | 344.0 | 344.0 | 8.0 | False | None | None | False | None | False | 2752.0 | 0 |
2590517 | 80565 | None | code110 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.---6Amps one way Switch -- Page No.--9--Item No. -- 3.6.1 | Each | 102.0 | 102.0 | 95.0 | False | None | None | False | None | False | 9690.0 | 0 |
2590518 | 80565 | None | code111 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.--6Amps Two way Switch -- Page No.--9--Item No. -- 3.6.2 | Each | 166.0 | 166.0 | 4.0 | False | None | None | False | None | False | 664.0 | 0 |
2590519 | 80565 | None | code112 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.--6Amps 3way socket -- Page No.--9--Item No. -- 3.6.3 | Each | 171.0 | 171.0 | 60.0 | False | None | None | False | None | False | 10260.0 | 0 |
2590520 | 80565 | None | code113 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.---Stepped Fan Regulator -- Page No.--9--Item No. -- 3.6.4 | Each | 357.0 | 357.0 | 8.0 | False | None | None | False | None | False | 2856.0 | 0 |
2590521 | 80565 | None | code114 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.--16Amps one way switch -- Page No.--9--Item No. -- 3.6.8 | Each | 180.0 | 180.0 | 5.0 | False | None | None | False | None | False | 900.0 | 0 |
2590522 | 80565 | None | code115 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.-6/16Amps universal socket -- Page No.--9--Item No. -- 3.6.11 | Each | 236.0 | 236.0 | 5.0 | False | None | None | False | None | False | 1180.0 | 0 |
2590523 | 80565 | None | code116 | Supplying And Fixing M.S Rafter Clamp Set made out of M.S Flat & 14mm M.S rod. -- Page No.--4--Item No. -- 1.11 | Nos | 160.0 | 160.0 | 8.0 | False | None | None | False | None | False | 1280.0 | 0 |
2590524 | 80565 | None | code117 | Supplying And Fixing Metal Fan Box with Round Hook. -- Page No.--4--Item No. -- 1.12 | Nos | 117.0 | 117.0 | 8.0 | False | None | None | False | None | False | 936.0 | 0 |
2590525 | 80565 | None | code118 | Extra length of GI pipe of class B 19mm dia for down rod. -- Page No.--57--Item No. -- 13.12 | Nos | 197.0 | 197.0 | 8.0 | False | None | None | False | None | False | 1576.0 | 0 |
2590526 | 80565 | None | code119 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.---1.5 sqmm -- Page No.--5--Item No. -- 2.3.2 | m | 26.0 | 26.0 | 100.0 | False | None | None | False | None | False | 2600.0 | 0 |
2590527 | 80565 | None | code120 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.---2.5 sqmm -- Page No.--5--Item No. -- 2.3.3 | m | 42.0 | 42.0 | 325.0 | False | None | None | False | None | False | 13650.0 | 0 |
2590528 | 80565 | None | code121 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.---4.0 sqmm -- Page No.--5--Item No. -- 2.3.4 | m | 63.0 | 63.0 | 450.0 | False | None | None | False | None | False | 28350.0 | 0 |
2590529 | 80565 | None | code122 | Supplying of 4feet - PVC Batten with integrated LED tube with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.----LED light fighting 2'-14watts -- Page No.--43--Item No. -- 11.3.1 | Each | 551.0 | 551.0 | 5.0 | False | None | None | False | None | False | 2755.0 | 0 |
2590530 | 80565 | None | code123 | Supplying of 4feet - PVC Batten with integrated LED tube with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.---LED light fighting 4'-36watts -- Page No.--43--Item No. -- 11.3.3 | Each | 1269.0 | 1269.0 | 20.0 | False | None | None | False | None | False | 25380.0 | 0 |
2590531 | 80565 | None | code124 | Supply of round/square recess/surface mounted rolling type LED Down light with GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition----LED square or round down light 15-18W -- Page No.--44--Item No. -- 11.3.1 | Each | 1324.0 | 1324.0 | 25.0 | False | None | None | False | None | False | 33100.0 | 0 |
2590532 | 80565 | None | code125 | Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. -- Page No.--30--Item No. -- 6.1 | Each | 1492.0 | 1492.0 | 5.0 | False | None | None | False | None | False | 7460.0 | 0 |
2590533 | 80565 | None | code126 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system.---48" Sweep (1200mm) Regular model -- Page No.--30--Item No. -- 6.3.1 | Each | 2984.0 | 2984.0 | 8.0 | False | None | None | False | None | False | 23872.0 | 0 |
2590534 | 80565 | None | code127 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. -- Page No.--56--Item No. -- 13.7.1 | Each | 122.0 | 122.0 | 50.0 | False | None | None | False | None | False | 6100.0 | 0 |
2590535 | 80565 | None | code128 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. -- Page No.--57--Item No. -- 13.10 | Each | 171.0 | 171.0 | 8.0 | False | None | None | False | None | False | 1368.0 | 0 |
2590536 | 80565 | None | code129 | Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 amps. ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire. -- Page No.--57--Item No. -- 13.14 | Each | 492.0 | 492.0 | 5.0 | False | None | None | False | None | False | 2460.0 | 0 |
2590537 | 80565 | None | code130 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifcations, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work---Soft Rock9 (without blasting) (Vol.1, P6 - 1.5.1) In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 307.97 | 307.97 | 92.44 | False | None | None | False | None | False | 28468.7468 | 0 |
2590538 | 80565 | None | code131 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (Vol.1, P7, I - 1.9) | Cum | 273.98 | 273.98 | 92.44 | False | None | None | False | None | False | 25326.7112 | 0 |
2590539 | 80565 | None | code132 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & formwork shall be paid separately) - Mix 1:4:8 (M5) Using 40 mm nominal size graded crushed coarse aggregates. (Vol.1, P 15, I 2.1.2) | Cum | 5833.92 | 5833.92 | 8.87 | False | None | None | False | None | False | 51746.8704 | 0 |
2590540 | 80565 | None | code133 | Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (Vol.2, P 9, I 5.3) | Cum | 6391.15 | 6391.15 | 17.62 | False | None | None | False | None | False | 112612.063 | 0 |
2590541 | 80565 | None | code134 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (Vol.2, P 9, I 5.4) | Cum | 6580.67 | 6580.67 | 17.62 | False | None | None | False | None | False | 115951.4054 | 0 |
2590542 | 80565 | None | code135 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticizers laid in fnished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & formwork to be paid separately) -- M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Vol.1, P 15, I - 2.2.1) | Cum | 6475.61 | 6475.61 | 7.05 | False | None | None | False | None | False | 45653.0505 | 0 |
2590543 | 80565 | None | code136 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticizers laid in fnished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & formwork to be paid separately) --- Addition for Formwork, Centering and Scaffolding. Add 8% of total quantity. | Cum | 518.05 | 518.05 | 7.05 | False | None | None | False | None | False | 3652.2525 | 0 |
2590544 | 80565 | None | code137 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) -- RCC Column M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Vol.1, P 17, I 2.5.1) | Cum | 6367.46 | 6367.46 | 5.22 | False | None | None | False | None | False | 33238.1412 | 0 |
2590545 | 80565 | None | code138 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--- ADDITION for Formwork, Centering and Scafolding. Add 70% of quantity. | Cum | 4457.22 | 4457.22 | 5.22 | False | None | None | False | None | False | 23266.6884 | 0 |
2590546 | 80565 | None | code139 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken foors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labor, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) RCC Plinth Beam M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Vol.1, P 16, I 2.3.1) | Cum | 6512.69 | 6512.69 | 5.22 | False | None | None | False | None | False | 33996.2418 | 0 |
2590547 | 80565 | None | code140 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken foors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & formwork to be paid separately) ----- ADDITION for Formwork, Centering and Scafolding. Add 50% of quantity. | Cum | 3256.35 | 3256.35 | 5.22 | False | None | None | False | None | False | 16998.147 | 0 |
2590548 | 80565 | None | code141 | Providing Thermo-Mechanically Treated bars of grade Fe-500 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members wherever necessary complete as per Design including cost of material, labour, usage charges complete as per specifcations. (The laps and wastages shall not be measured separately) (Vol.2, P-18, I -- 2.11-a) | Kg | 92.14 | 92.14 | 1541.76 | False | None | None | False | None | False | 142057.7664 | 0 |
2590549 | 80565 | None | code142 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifcations. (Vol.2, P17, I 6.32) | Sqm | 1349.3 | 1349.3 | 191.4 | False | None | None | False | None | False | 258256.02 | 0 |
2590550 | 80565 | None | code143 | Providing 15 mm cement plaster of mix :1:4 (1 cement: 4 fne sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifcations and as per directions of Engineer-in-charge. (Vol.2, P 41, I 8.2.1) | Sqm | 303.85 | 303.85 | 381.35 | False | None | None | False | None | False | 115873.1975 | 0 |
2590551 | 80565 | None | code144 | Finishing walls with water proofng cement paint of required shade:Old work (one coats applied @ 2.20 kg/10 m²) over priming coat of primer applied @ 0.80 litrs/10 m² complete including cost of Priming coat including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifcations and as per directions of Engineer-in-charge. (Vol.2, P 52, I 8.72.1) | Sqm | 89.61 | 89.61 | 381.35 | False | None | None | False | None | False | 34172.7735 | 0 |
2590552 | 80565 | None | code145 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with raw plugs screws etc. (CORR/Vol.2, P 85, I 11.34B) | Kg | 188.49 | 188.49 | 1384.2 | False | None | None | False | None | False | 260907.858 | 0 |
2590553 | 80565 | None | code146 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifcations and as per directions of Engineer-in-charge. (Vol. 2, P 47, I 8.33.3) | Sqm | 143.17 | 143.17 | 59.4 | False | None | None | False | None | False | 8504.298 | 0 |
2590554 | 80565 | None | code147 | Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. (.P64 I9.32) | Sqm | 2659.46 | 2659.46 | 130.5 | False | None | None | False | None | False | 347059.53 | 0 |
2590555 | 80565 | None | code148 | Underground Drain at Edge of Pavement Construction of an underground drain 1 m x 1 m (inside dimensions) lined with RCC M-20, 15 cm thick and covered with RCC slab10 cm in thickness on urban roads.Pg 26 Vol III - 3.30 309 | Sqm | 4969.75 | 4969.75 | 90.0 | False | None | None | False | None | False | 447277.5 | 0 |
2590556 | 80565 | None | code149 | Providing and laying 100mm thick pre-cast cover slabs over Road side drains / utility ducts / Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 550 @ 6kg/ m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drain age of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. (P172.I - 17.14 ) | Sqm | 1205.1 | 1205.1 | 90.0 | False | None | None | False | None | False | 108459.0 | 0 |
2590557 | 80565 | None | code150 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) -- RCC Column M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Vol.1, P 17, I 2.5.1) | Cum | 6828.9 | 6828.9 | 15.17 | False | None | None | False | None | False | 103594.413 | 0 |
2590558 | 80565 | None | code151 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) -- ADDITION for Formwork, Centring and Scaffolding. Add 70% of quantity. | Cum | 4780.23 | 4780.23 | 1.13 | False | None | None | False | None | False | 5401.6599 | 0 |
2590559 | 80565 | None | code152 | Providing Thermo-Mechanically Treated bars of grade Fe-500 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members wherever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) (Vol.1, P18, 2.11.a) | Kg | 92.14 | 92.14 | 1190.88 | False | None | None | False | None | False | 109727.6832 | 0 |
2590560 | 80565 | None | code153 | Providing 15 mm cement plaster of mix :1:4 (1 cement: 4 fne sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Vol.2, P 41, I 8.2.1) | Sqm | 303.85 | 303.85 | 163.01 | False | None | None | False | None | False | 49530.5885 | 0 |
2590561 | 80565 | None | code154 | Providing & fixing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge(P21. vol-II -- 7.1.1) --. 7.1.1 0.63 mm thick with zinc coating not less than 275 g/ m² | Sqm | 905.37 | 905.37 | 500.0 | False | None | None | False | None | False | 452685.0 | 0 |
2590562 | 80565 | None | code155 | 7.4 Providing & fixing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete as per design drawings. 7.4.1 0.63 mm thick with zinc coating not less than 275 g/m² m | m | 562.38 | 562.38 | 56.0 | False | None | None | False | None | False | 31493.28 | 0 |
2590563 | 80565 | None | code156 | Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.(P21. II - 7.4 ) -- 0.63 mm thick with zinc coating not less than 275 g/ m² -- 7.4.1 | m | 658.17 | 658.17 | 95.0 | False | None | None | False | None | False | 62526.15 | 0 |
2590564 | 80565 | None | code157 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Vol-II -- 11.16.2) -- 100mmx100mm 4m thick top and bottom14.41kg/m -- 72 x72mm 3.2mm tk 5.5kg/m | Kg | 151.41 | 151.41 | 4804.8 | False | None | None | False | None | False | 727494.768 | 0 |
2590565 | 80565 | None | code158 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Vol. 2, P 47, I 8.33.3) | Sqm | 143.17 | 143.17 | 172.8 | False | None | None | False | None | False | 24739.776 | 0 |
2590566 | 80565 | None | code159 | Earth work excavation for pipeline trenches in all kinds of by mechanical means above 600 mm trench width as per drawing and technical specifcations, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm whevere necessary as directed, removal of slumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work and all other appurtenances to complete in the following strata. --Ordinary/soft rock (without requiring blasting) Depth upto 1.50 m (Vol.1, P 10, I 1.19.1) | Cum | 467.62 | 467.62 | 135.0 | False | None | None | False | None | False | 63128.7 | 0 |
2590567 | 80565 | None | code160 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: -- Pipes of SN4, 160mm dia. (Vol.5.P. 134 I.2.4/ M020D ) | m | 593.28 | 593.28 | 150.0 | False | None | None | False | None | False | 88992.0 | 0 |
2590568 | 80565 | None | code161 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: -- Pipes of SN4, 110mm dia. (Vol.5.P. 134 I 2.2 /M020B) | m | 296.64 | 296.64 | 130.0 | False | None | None | False | None | False | 38563.2 | 0 |
2590569 | 80565 | None | code162 | Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. (Vol.5, P 191, 16.10) | Each | 4363.08 | 4363.08 | 12.0 | False | None | None | False | None | False | 52356.96 | 0 |
2590570 | 80565 | None | code163 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.. (Vol.5, P 191, 16.09) | Each | 5617.62 | 5617.62 | 12.0 | False | None | None | False | None | False | 67411.44 | 0 |
2590571 | 80565 | None | code164 | 37 T500C Providing and fixing 150mm dia. Cast Iron pipe for ventilatiing shaft 5 M high with specials and cowl and with suitable grips in CC 1:2:4 pillar using 10mm to 20mm graded hard granite, with 15 cms. thick cement concrete 1:2:4 around upto 1.22 M above the GLR and with a foundation base of 90 x 90 x 90 cms. plastered with 12mm thick CM 1:3 to all exposed faces and linking the shaft to the manholes by means of 150mm dia. GSW pipes and specials, jointing with tar dipped hemp 1:1.5 CM caulking, curing. The cost include all lead and lifts for all materials, earth work excavations and refilling in all strata, disposal of surplus earth etc. complete vol-5 p200 - 16.37 | Each | 21719.61 | 21719.61 | 1.0 | False | None | None | False | None | False | 21719.61 | 0 |
2590572 | 80565 | None | code165 | 40 T510 Providing and constructing of Machinehole chambers conical in shape at top with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15m alround the chamber and brick masonry in C.M 1:4 plaster with bricks of approved quality and CM plaster 1:3 proportion 12mm thick inside and outside except for the conical surface outside where the thickness of plaster shall be 20 mm thick, with 1 to 6 slope in the concrete towards the central drain, finished smooth and fixing of pipes in CC 1:2:4 with graded metal of 20 mm and down size including supplying and fixing SFRC Machinehole frame and cover confoming to IS 12592(Part-I): 1988 & IS 12592(Part-II) :1991 with latest amendments in CC 1:2:4, supplying and fixing of plastic foot steps staggered at 30cms apart as directed, watering, curing,barricading, danger lighting, pouring tar over M.H. frame and cover, cost of tar, shoring, strutting, dewatering, engraving Machinehole No. on the inner and outer conical surface etc. as per the drawing with all lead and lift for various diameters and depths noted below. With Table Moulded Bricks & Medium Duty SFRC Cover & Frame: For 1.2m dia 40.1 T510A Constructing Table Moulded Bricks Machinehole Vol-5 - p201-16.40.1 -- 1.2 m internal dia. , 1.0 M depth & Medium duty SFRC cover & frame | Each | 21854.54 | 21854.54 | 1.0 | False | None | None | False | None | False | 21854.54 | 0 |
2590573 | 80565 | None | code166 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifcations, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.-----In ordinary/soft rock without blasting upto 1.5 m depth. (Vol. 1, P 6, I 1.5.1) | Cum | 307.97 | 307.97 | 12.75 | False | None | None | False | None | False | 3926.6175 | 0 |
2590574 | 80565 | None | code167 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifcations, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.---Depth exceeding 1.5m, but not exceeding 3 m (Vol. 1, P 6, I 1.5.2) | Cum | 458.35 | 458.35 | 8.63 | False | None | None | False | None | False | 3955.5605 | 0 |
2590575 | 80565 | None | code168 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (Vol.1, P6, I 1.9) | Cum | 273.98 | 273.98 | 60.3 | False | None | None | False | None | False | 16520.994 | 0 |
2590576 | 80565 | None | code169 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & formwork shall be paid separately) --Mix 1:4:8 (M5) Using 40 mm nominal size graded crushed coarse aggregates. (Vol.1, P 15, I 2.1.2) | Cum | 5833.92 | 5833.92 | 1.92 | False | None | None | False | None | False | 11201.1264 | 0 |
2590577 | 80565 | None | code170 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (Vol.2, P 9, I 5.4) | Cum | 6580.67 | 6580.67 | 11.76 | False | None | None | False | None | False | 77388.6792 | 0 |
2590578 | 80565 | None | code171 | Providing and filling on foundation with granite / trap broken metal 100 mm, and down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications. Vol. 2, P 11, -- 1.23 | Cum | 2762.46 | 2762.46 | 46.88 | False | None | None | False | None | False | 129504.1248 | 0 |
2590579 | 80565 | None | code172 | Supplying, flling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. (Vol. 2, P 151, I 17.1) | Cum | 1032.06 | 1032.06 | 15.63 | False | None | None | False | None | False | 16131.0978 | 0 |
2590580 | 80565 | None | code173 | Supplying, flling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. (Vol. 2, P 151, I 17.2) | Cum | 1221.58 | 1221.58 | 15.63 | False | None | None | False | None | False | 19093.2954 | 0 |
2590581 | 80565 | None | code174 | Supplying, flling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. (Vol. 2, P 151, I 17.3) | Cum | 1227.76 | 1227.76 | 6.25 | False | None | None | False | None | False | 7673.5 | 0 |
2590582 | 80565 | None | code175 | Planting of trees by the road side (Avenue trees) in 0.60m dia holes, 1m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, planting the saplings, backfilling the trench, watering, fixing the tree guard and miantaining the plants for one year complete as per specifications. (Pg. No-148, I.No-19.88) | Each | 721.0 | 721.0 | 50.0 | False | None | None | False | None | False | 36050.0 | 0 |
2590583 | 80565 | None | code176 | KSRRB M300-1 : Spreading of sludge farm yard manure or /and good earth in required thickness (Cost of sludge, farm yard manure or / and good earth to be paid for separately ) Complete as per specifications No. 307. MORTH (PWD SR2016-17/P.No.149/19.77) | Cum | 65.92 | 65.92 | 22.5 | False | None | None | False | None | False | 1483.2 | 0 |
2590584 | 80565 | None | code177 | KSRRB M300-2.2 : Grassing with Doobs grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for moving including supplying good earth if needed complete as per specifications. MORTH Specification No.307. ii) In rows 7.5 cm apart in either direction. (PWD SR2016-17P.No.149/19.79) | Sqm | 48.56 | 48.56 | 150.0 | False | None | None | False | None | False | 7284.0 | 0 |
2590585 | 80565 | None | code178 | KSRRB M300-2.2 : Grassing with Doobs grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for moving including supplying good earth if needed complete as per specifications. MORTH Specification No.307. ii) In rows 7.5 cm apart in either direction. (PWD SR2016-17P.No.149/19.79) | Sqm | 92.7 | 92.7 | 112.5 | False | None | None | False | None | False | 10428.75 | 0 |
2590586 | 80565 | None | code179 | Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge (PWD /9.32) VOL-II | Sqm | 2659.46 | 2659.46 | 110.0 | False | None | None | False | None | False | 292540.6 | 0 |
2590587 | 80565 | None | code180 | Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 600 x 300 x 100 mm Kerb Stone | m | 249.9 | 249.9 | 50.0 | False | None | None | False | None | False | 12495.0 | 0 |
2590588 | 80565 | None | code181 | Supplying S Type Chairs (MR)(Ground 40+First 63) | Nos | 1271.19 | 1271.19 | 125.0 | False | None | None | False | None | False | 158898.75 | 0 |
2590589 | 80565 | None | code182 | Providing and Fixing Computer LOW BACK CHAIR WITH P.U.ARMS WITH GASLIFT.Model LP-113 "including supplying and Fixing Etc.., Complete (Featherlite Collection OR Equivalent brand) | Nos | 6483.05 | 6483.05 | 25.0 | False | None | None | False | None | False | 162076.25 | 0 |
2590590 | 80565 | None | code183 | Supplying and Fixing MS Cot, coir bed, one pillow and 2 nos bed sheet including all labour chrages etc.., | Nos | 5847.46 | 5847.46 | 110.0 | False | None | None | False | None | False | 643220.6 | 0 |
2590591 | 80565 | None | code184 | Supply and Fixing Steel Plate including all labour chrages etc.., | Nos | 219.49 | 219.49 | 110.0 | False | None | None | False | None | False | 24143.9 | 0 |
2590592 | 80565 | None | code185 | Supply and Fixing Steel Glass including all labour chrages etc.., | Nos | 72.88 | 72.88 | 110.0 | False | None | None | False | None | False | 8016.8 | 0 |
2590593 | 80565 | None | code186 | Supplying and Fixing Cooking Vessels including all labour chrages etc.., | Kg | 341.53 | 341.53 | 112.5 | False | None | None | False | None | False | 38422.125 | 0 |
2590594 | 80565 | None | code187 | Supplying and fixing Big Size Plate including all labour chrages etc.., | Nos | 341.53 | 341.53 | 30.0 | False | None | None | False | None | False | 10245.9 | 0 |
2590595 | 80565 | None | code188 | Supplying and Fixing Steel Bucket including all labour chrages etc.., | Nos | 731.36 | 731.36 | 25.0 | False | None | None | False | None | False | 18284.0 | 0 |
2590596 | 80565 | None | code189 | Supplying and Fixing Medeium size spoons including all labour chrages etc.., | Nos | 244.07 | 244.07 | 20.0 | False | None | None | False | None | False | 4881.4 | 0 |
2590597 | 80565 | None | code190 | Big Size spoons including all labour chrages etc.., | Nos | 974.58 | 974.58 | 15.0 | False | None | None | False | None | False | 14618.7 | 0 |
2590598 | 80565 | None | code191 | Supplying and Fixing Dosa thava including all labour chrages etc.., | Nos | 2436.44 | 2436.44 | 3.0 | False | None | None | False | None | False | 7309.32 | 0 |
2590599 | 80565 | None | code192 | Supplying and Fixing Idly Cookker including all labour chrages etc.., | Nos | 4872.88 | 4872.88 | 3.0 | False | None | None | False | None | False | 14618.64 | 0 |
2590600 | 80565 | None | code193 | Supplying and Fixing Jalra including all labour chrages etc.., | Nos | 487.29 | 487.29 | 1.0 | False | None | None | False | None | False | 487.29 | 0 |
2590601 | 80565 | None | code194 | Supplying and ixing Non stick Spoons including all labour chrages etc.., | Nos | 146.61 | 146.61 | 1.0 | False | None | None | False | None | False | 146.61 | 0 |
2590602 | 80565 | None | code195 | Supplying and Fixing Kniefs Set including all labour chrages etc.., | Nos | 487.29 | 487.29 | 1.0 | False | None | None | False | None | False | 487.29 | 0 |
2590603 | 80565 | None | code196 | Supplying and Fixing Cooking Vessels (bandly) including all labour chrages etc.., ---Medium Size | Nos | 974.58 | 974.58 | 1.0 | False | None | None | False | None | False | 974.58 | 0 |
2590604 | 80565 | None | code197 | Supplying and Fixing Cooking Vessels (bandly) including all labour chrages etc.., ---Large size | LS | 1461.86 | 1461.86 | 1.0 | False | None | None | False | None | False | 1461.86 | 0 |
2590605 | 80565 | None | code198 | Supplying & Installing, testing and commissioning of Shower mixer unit with 15mm dia. bend pipe, spout and overhead shower comprising of CP shower arm, pressure adjustable shower rose with CP wall flanges , wall mixer etc., complete. | Nos | 4067.8 | 4067.8 | 6.0 | False | None | None | False | None | False | 24406.8 | 0 |
2590606 | 80565 | None | code199 | Provoding & fixing testing and commissioning u PVC multi inlet floor trap conforming to IS 13592 with required P C support placed to required level as per site condition complete. 110mm dia inlet 75mm dia outlet , Make: PRINCE / ASHIRWAD / SUPREME / equivalent | Nos | 146.61 | 146.61 | 10.0 | False | None | None | False | None | False | 1466.1 | 0 |
2590607 | 80565 | None | code200 | Fixing of approved make vertical / horizontal type Electric water heater with heating elements with thermostat, 2 Nos. 15 mm dia. CP angle valve, pressure relief valve, non-return valve with CP copper connecting pipes with wall flanges etc., complete. a) Capacity : 100 lts. 3 K.W heating element | Nos | 8050.85 | 8050.85 | 2.0 | False | None | None | False | None | False | 16101.7 | 0 |
2590608 | 80565 | None | code201 | Waste Water Treatment by Prefabricated anaerobic Bio Septic tank : (For 100 Souls/10KLD) Providing, installation and commissioning of an anaerobic Bio Septic tank with all necessary accessories such as pre-filter, pipes, prefabricated RCC Tank (including internal matrix for enhanced growth of Bacteria), Anaerobic microbial Inoculum developed by DRDO and baffle wall to control the flow of water and to increase the retention time in the RCC Tank (Note: Refer to technical specification attached as Annexure-1) including cost of material, loading and unloading and as directed by the Engineer in charge etc., complete, including annual maintenance of the system for 5 years. Note :- 1. Above rates mentioned are for the purpose of preparation of estimate only. 2. All items are of ISI standards. 3. After commissioning of plant necessary testing to be done for the satisfaction of the engineer in charge. 4. Design drawing of the system suitable for erection is given in figures. Vol-5 - p 251- 22.1 | Nos | 927000.0 | 927000.0 | 1.0 | False | None | None | False | None | False | 927000.0 | 0 |