createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1707733868455
version10
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd1396800.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose01-03-2024 17:30:00
tenderQueryClose28-02-2024 17:30:00
technicalBidOpen04-03-2024 17:30:00
publishedDate15-02-2024 13:05:43
publishedByPostPWD_EE_DIV_UDP
publishedByUserKPE10086 - DINESH K N
bidValidityPeriod90
noOfCalls1
preBidMeetingDate29-02-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonShanthala JG
splitEmdRequiredYnTrue
emdBankGuarantee1296800.00
emdCash100000.00
bgValidityPeriod135
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08202531802
mobileNumber7019413273
tenderSupplierListNone
tenderSchedule
createdTs1707733868515
version15
createdDateNone
modifiedDateNone
tenderNumberPWD/2023-24/BD/WORK_INDENT7229
titleCONSTRUCTION OF SUTHU POULI AND MUKHA MANTAPA AT SHREE HOSA MARIGUDI TEMPLE IN KAUP, UDUPI DISTRICT (PHASE-I WORK)
descriptionCONSTRUCTION OF SUTHU POULI AND MUKHA MANTAPA AT SHREE HOSA MARIGUDI TEMPLE IN KAUP, UDUPI DISTRICT (PHASE-I WORK)
categoryWORKS
categoryTextWorks
ecv80821594.51
deptNamePublic Works Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location1698
locationNamePWD Division Office Udupi
provisionalAmount99500000.0
groupOverheadTotal0.0
fileNumberKPWD/UDP/BUILDING/KAUP/MARIGUDI/2023-24/
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17077338690001NoneNoneBuildingsCIVIL WORK (EXCLUDING GST)60827162.81
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
255445278448NonePWD SR 2023-24 Volume-1 Page No:- 08 Item No:1.4.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing ofexcavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5m including cost of labour, tools, usage of machinery & other appurtenacesrequired to complete the work 1.14.1 In all kinds of soils Depth upto 3 mCum114.24114.24437.49FalseNoneNoneFalseNoneFalse49978.85760
255445378448NonePWD SR 2023-24 Volume-1 Page No:15 Item No:-2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregatesCum6707.686707.68195.12FalseNoneNoneFalseNoneFalse1308802.52160
255445478448NonePWD SR 2023-24 Volume-2 Page No:- 9 INo:-5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum7155.687155.68372.18FalseNoneNoneFalseNoneFalse2663200.98240
255445578448NonePWD SR 2023-24 Volume-1 Page No:16 Item No:2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Cum11496.2411496.24241.34FalseNoneNoneFalseNoneFalse2774502.56160
255445678448NonePWD SR 2023-24 Volume-1 Page No:- 18 Item No:2.11Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.(The laps and wastages measured seperately) t100191.84100191.8433.11FalseNoneNoneFalseNoneFalse3317351.82240
255445778448NonePWD SR 2023-24 Volume-1 Page No:-7 Item No:1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum297.92297.923982.98FalseNoneNoneFalseNoneFalse1186609.40160
255445878448NonePWD SR 2023-24 Volume-2 Page No:149 Item No:-15.1Polyurethane based Single Component for New Surface Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specificationSqm915.04915.041149.72FalseNoneNoneFalseNoneFalse1052039.78880
255445978448NonePWD SR 2023-24 Volume-1 Page No: 15 Item No:-2.1.6Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates Cum6992.166992.16114.98FalseNoneNoneFalseNoneFalse803958.55680
255446078448NonePWD SR 2023-24 Volume-2 Page No:63 Item No:-9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalentSqm3194.243194.241869.55FalseNoneNoneFalseNoneFalse5971791.3920
255446178448NonePWD SR 2023-24 Volume-2 Page No:71 Item No:10.18Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold granite, grey granite in CM 1:3 (1 cement : 3 coarse sand) proportion cut to required shape, pattern with paper joints, finished with cement mortal using white cement and colour pigments to match the colour of slab making through jointing with sealant, making holes 25mmx12mm grooves in joints including cost of all materials, mortar, labour, curing etc., complete.Sqm3762.083762.08579.74FalseNoneNoneFalseNoneFalse2181028.25920
255446278448NonePWD SR 2023-24 Volume-2 Page No:- 71 Item No:10.14Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg/m2, including pointing in white cement mixed with pigment of matching shade complete.Sqm1238.721238.72174.0FalseNoneNoneFalseNoneFalse215537.280
255446378448NonePWD SR 2023-24 Volume-2 Page No:183 I No:11.16.1Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Kgs152.32152.3239169.79FalseNoneNoneFalseNoneFalse5966342.41280
255446478448NonePWD SR 2023-24 Volume-2 Page No:183 Item No:18.5Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi -rigid, inorganic, non-combustible fibre glass wool insulation 50 mm thick, conforming to IS: 8183 and BS: 3958 Part 5. The insulation layer shall have facing (factory bonded on surface 1 of the fibre glass insulation layer), of black non-woven fibre glass tissue of nominal thickness 0.5 mm and nominal mass not less than 60 g/m2,made of randomly oriented glass fibres distributed in a binder by a wet-lay process including fixing 1.5 mm thick solid aluminum sheet backing using, 6 mm thick cement board including SS rivets, nuts, bolts, washers etc complete.Sqm2171.682171.68652.83FalseNoneNoneFalseNoneFalse1417737.85440
255446578448NonePWD SR 2023-24 Volume-2 Page No:17 INo:-6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1236.481236.48211.2FalseNoneNoneFalseNoneFalse261144.5760
255446678448NonePWD SR 2023-24 Volume-2 Page No:15 Item No:6.20Providing Tile brick masonry with common burnt clay Non Modular tile bricks of class designation 5.0 conforming to IS 2690 (Part I) in superstructure above plinth level up to floor I level in cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum18700.6418700.6497.83FalseNoneNoneFalseNoneFalse1829483.61120
255446778448NonePWD SR 2023-24 Volume-2 Page No: 45 Item No:8.29Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm316.96316.961616.08FalseNoneNoneFalseNoneFalse512232.71680
255446878448NonePWD SR 2023-24 Volume-2 Page No:46 Item No:-8.31Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargesSqm199.36199.36709.04FalseNoneNoneFalseNoneFalse141354.21440
255446978448NoneData RateProviding and construction Ahistana around the garbhagudi using gray granite stone. The stones shall be dressed to four nuli, making surface nice and shall be carved as per the design , drawing ans specification . The work shall be constructed using surkhi ( a micture of lime, sand and jaggery ) and the length of granite stones should be more than 1.00 m. the thickness and height of stones shall be as per the design and drawing , including cost and coveyance of all materials with all lead and lift, loading and unloading, dressin, scaffolding, hire charges, all statutory taxes and all other incidental charges etc.., complete as per standardtechnical specification , design and directions of the engineer incharge of work.Cum48200.048200.0509.2FalseNoneNoneFalseNoneFalse24543440.00
255447078448NoneData RateProviding and construction sutthupouli wall using gray granite stone. The stones shall be dressed to four nuli, making surface nice and shall be carved as per the design , drawing ans specification . The work shall be constructed using surkhi ( a micture of lime, sand and jaggery ) and the length of granite stones should not be less than 0.90 m. the thickness and height of stones shall be as per the design and drawing , including cost and coveyance of all materials with all lead and lift, loading and unloading, dressin, scaffolding, hire charges, all statutory taxes and all other incidental charges etc.., complete as per standardtechnical specification , design and directions of the engineer incharge of work.Cum54600.054600.084.81FalseNoneNoneFalseNoneFalse4630626.00
17077338690000NoneNoneBuildingsCIVIL WORK (INCLUDING GST)12524200.0
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
255447178449NoneData RateProviding and construction of windows sutthu pouli wall in using Red colour Illikal granite stone. The stones shall be dressed to four nuli, making surface nice and shall be carved as per the design , drawing ans specification . The work shall be constructed using surkhi ( a micture of lime, sand and jaggery ) and length, thickness and height of stones shall be as per the design and drawing , including cost and coveyance of all materials with all lead and lift, loading and unloading, dressin, scaffolding, hire charges, all statutory taxes and all other incidental charges etc., complete as per standard technical specification , design and directions of the engineer incharge of work.No194000.0194000.038.0FalseNoneNoneFalseNoneFalse7372000.00
255447278449NoneData RateProviding and construction of columns in sutthu pouli wall using using gray granite stone. The stones shall be dressed to four nuli, making surface nice and shall be carved as per the design , drawing ans specification . The work shall be constructed using surkhi ( a micture of lime, sand and jaggery ), the base of column 0.60m x 0.60 m. the height of column is 2.40m and work shall be as per the design and drawing , including cost and coveyance of all materials with all lead and lift, loading and unloading, dressin, scaffolding, hire charges, all statutory taxes and all other incidental charges etc., complete as per standard technical specification , design and directions of the engineer incharge of work.Nos55800.055800.044.0FalseNoneNoneFalseNoneFalse2455200.00
255447378449NoneData RateProviding and construction of Mukhamantapa Gopura according to the sculpture using Red colour Illikal granite stone. The stones shall be dressed to four nuli, making surface nice and shall be carved as per the design , drawing ans specification . The gopura shall be constructed using surkhi ( a micture of lime, sand and jaggery ) and the length of granite stones should not be less than 1.50 m. the thickness and height of stones shall be as per the design and drawing , including cost and coveyance of all materials with all lead and lift, loading and unloading, dressin, scaffolding, hire charges, all statutory taxes and all other incidental charges etc., complete as per standardtechnical specification , design and directions of the engineer incharge of work. ( Top portion )Nos785000.0785000.01.0FalseNoneNoneFalseNoneFalse785000.00
255447478449NoneData RateProviding and construction of Mukhamantapa Gopura according to the sculpture using Red colour Illikal granite stone. The stones shall be dressed to four nuli, making surface nice and shall be carved as per the design , drawing ans specification . The gopura shall be constructed using surkhi ( a micture of lime, sand and jaggery ) and the length of granite stones should not be less than 1.50 m. the thickness and height of stones shall be as per the design and drawing , including cost and coveyance of all materials with all lead and lift, loading and unloading, dressin, scaffolding, hire charges, all statutory taxes and all other incidental charges etc., complete as per standardtechnical specification , design and directions of the engineer incharge of work. ( Middle portion )Nos832000.0832000.01.0FalseNoneNoneFalseNoneFalse832000.00
255447578449NoneData RateProviding and construction of Mukhamantapa Gopura according to the sculpture using Red colour Illikal granite stone. The stones shall be dressed to four nuli, making surface nice and shall be carved as per the design , drawing ans specification . The gopura shall be constructed using surkhi ( a micture of lime, sand and jaggery ) and the length of granite stones should not be less than 1.50 m. the thickness and height of stones shall be as per the design and drawing , including cost and coveyance of all materials with all lead and lift, loading and unloading, dressin, scaffolding, hire charges, all statutory taxes and all other incidental charges etc., complete as per standardtechnical specification , design and directions of the engineer incharge of work. ( Lower portion )Nos1080000.01080000.01.0FalseNoneNoneFalseNoneFalse1080000.00
17077338690000NoneNoneBuildingsELECTRICAL WORKS7470231.7
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
255447678450NoneCOMMON SR 2023-24 VOL-6,page No:17,item.no-41.01Load Break Switch Load Break Switch with PanelUnit73239.073239.01.0FalseNoneNoneFalseNoneFalse73239.00
255447778450NoneCOMMON SR 2023-24 VOL-6,p No:8,i.no-13.08Distribution Transformer - 3 Phase, 11kV/433V - Amorphous Core with Oil as per IS-1180 (Part-1) 2014 B. CABLE ENTRY TYPE 100 kVA, Aluminium Wdg, Star 2 (5 Star)No223811.0223811.01.0FalseNoneNoneFalseNoneFalse223811.00
255447878450NoneCOMMON SR 2023-24 VOL-6,page No:20,ino-45.07Heat Shrinkable Outdoor Type Cable Termination Kit for XLPE Cable 3x95 SqmmKit4067.04067.02.0FalseNoneNoneFalseNoneFalse8134.00
255447978450NoneCOMMON SR 2023-24 VOL-6, Page 15 ,i- 36.01HT CABLE. 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975 95 Sqmm, (54 GI Wires - 2.5 mm Dia)Mtr889.67889.6730.0FalseNoneNoneFalseNoneFalse26690.10
255448078450NoneCOMMON SR 2023-24, Page 52Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminium Rollers as directed by the departmental staff 3x95 to 150 SqmmMtr61.3261.3230.0FalseNoneNoneFalseNoneFalse1839.60
255448178450NoneCOMMON SR 2023-24 VOL-6, Page 09 ,i.no- 18.01LT Distribution Box as per IS-13947 Part1 AND 2 LT Distribution Box for 100 kVA DTC with MCCB's (Sheet Metal)Set22686.022686.01.0FalseNoneNoneFalseNoneFalse22686.00
255448278450NoneCOMMON SR 23-24 VOL-6, Page 09 ,i.no- 17.01Supplying and fixing of LT Wiring kit as per standard technical specification as per ESCOM LT Wiring Kit 63/100 KVA (Market Rate)Set2023.02023.01.0FalseNoneNoneFalseNoneFalse2023.00
255448378450NoneCOMMON SR2023-24 VOL-6, Page 49 I No.15.03Supplying and fixing of LT Wiring kit as per standard technical specification as per ESCOM.Fixing of LT Protection KitSet356.0356.01.0FalseNoneNoneFalseNoneFalse356.00
255448478450NoneCOMMON SR2023-24 VOL Page 49 I No.34.04Straight Through Jointing Kit Suitable for 1.1 kV Class LTUG Cable as per IS-13573 16 Sqmm, 4 CoreSet698.0698.06.0FalseNoneNoneFalseNoneFalse4188.00
255448578450NoneCOMMON SR2023-24 VOL-6, Page 49 I No.34.10Straight Through Jointing Kit Suitable for 1.1 kV Class LTUG Cable as per IS-13573 120 Sqmm, 3.5/4 CoreSet1664.01664.04.0FalseNoneNoneFalseNoneFalse6656.00
255448678450NoneKPWD SR 2023-24 Volume VI Page 54 Sl. No. 12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm diaNo3510.03510.06.0FalseNoneNoneFalseNoneFalse21060.00
255448778450NoneKPWD SR 2023-24 Volume 6 Page 54 Sl.No. 12.57Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40 mm dia 2.9 mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400 mm with a cast iron cover. The earth electrode shall have staggered holes of 12 mm dia and the electrode should be covered 150 mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nutsNo4256.04256.04.0FalseNoneNoneFalseNoneFalse17024.00
255448878450NoneKPWD SR 2023-24 Vol VI Page 54 Sl. No. 12.58.2GI/Copper strips for grounding connections, using necessary fixing materials as required 25 x 3 mm GI stripMtr82.082.0100.0FalseNoneNoneFalseNoneFalse8200.00
255448978450NoneKPWD SR 2023-24Vol VI Page 55 Sl. No. 12.58.7GI/Copper strips for grounding connections, using necessary fixing materials as required 25 x 3 mm Copper stripMtr570.0570.040.0FalseNoneNoneFalseNoneFalse22800.00
255449078450NoneKPWD SR 2023-24 Volume VI Page 55 Sl. No. 12.58.11GI/Copper strips for grounding connections, using necessary fixing materials as required 600 x 600 x 3 mm Copper plateEach7421.07421.04.0FalseNoneNoneFalseNoneFalse29684.00
255449178450NoneKPWD SR 2023-24 VOL-1,Page7 , i no. 1.10Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead up to 50 m, and lift up to 1.5 m. Including cost of all labour complete as per specificationsCum160.0160.025.2FalseNoneNoneFalseNoneFalse4032.00
255449278450NoneKPWD SR 2023-24VOL-1 ,Page A-38 item no. 20Brick - Table Moulded BricksEach8.08.0200.0FalseNoneNoneFalseNoneFalse1600.00
255449378450NoneKPWD SR 2023-24 VOL-1 ,PageA-40 I no. 64Sand - M-SandCum1476.01476.03.0FalseNoneNoneFalseNoneFalse4428.00
255449478450NoneKPWD SR 2023-24VOL page No:56,item.no- 28.07Laying and Jointing the pipes (100-150 mm Dia) including lowering in Position: Fixing Collars etc., Joining with mud mortar complete. Stone Ware PipeMtr56.056.050.0FalseNoneNoneFalseNoneFalse2800.00
255449578450NoneKPWD SR 2023-24 Vol VIPage 55 Sl. No. 12.59.12 mm thick perforated cable GI tray with on existing MS angle support using necessary GI bolts/nuts and washer or welding as required 150 x 50 mmMtr463.0463.0150.0FalseNoneNoneFalseNoneFalse69450.00
255449678450NoneKPWD SR 2023-24 Vol VIPage 55 Sl. No. 12.59.22 mm thick perforated cable GI tray with on existing MS angle support using necessary GI bolts/nuts and washer or welding as required 300 x 50 mmMtr587.0587.050.0FalseNoneNoneFalseNoneFalse29350.00
255449778450NoneKPWD SR 2023-24 Vol VIPage 42 Sl. No. 10.1.9Supplying, installing, testing and commissioning of Diesel Generator set with following specifications.The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade), Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation.Capacity of Fuel Tank Fuel tank suitable for 8 hours of operation Alternator: Alternator is suitable for operation at 1500 RPM, 415 V, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming to IS/IEC 60034-1. The Alternator is brush less type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have 1.0% Voltage regulation (max) in static conditions- IP: 23 protections with insulation class F and H. Mounting arrangement: Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), Kva (3 PH AND TOTAL), Frequency, Provide, Current (1 PH OR 3 PH), kVA (3 PH AND TOTAL), Frequency, Provide Engine Data, Starting battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,- Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The Acoustic enclosure: The acoustic enclosure shall be made of 1.6mm thick CRCA sheets in suitable approved shade and a structural/ sheet metal base frame painted in black. The walls of the enclosure are insulated with the fire retardant foam so as to comply with the 75dBA at 1 mtrs sound levels specified by Ministry of Environment & Forest. The enclosure has the following feature: Specially designed to meet stringent MOEF/ CPCB norms of 75dBA at 1mtr at 75 percentage load under free field condition, Two point lifting for easy handling at customer site, Designed to have optimum serviceability, Air inlet louvers specially designed to operate at rated load made on special purpose CNC machines for consistency in quality and workmanship, Powder coated for long lasting service life and superior finish, with UV resistant powder coating, can withstand extreme environment, Use of special hardware for longer life, Insulation material meets exacting IS 8183 specifications for better sound attenuation, flush styling - no projections, Fluid drains for lube oil and fuel, Fuel filling point inside the enclosure. The complete set shall have sufficient safety and adhere to NEC 2016, IEC, CPWD Specifications, PCB Norms and KSGEI Acts and Rules.100 KVA/ 80 kwSet900956.0900956.01.0FalseNoneNoneFalseNoneFalse900956.00
255449878450NoneKPWD SR 2023-24Vol VI Page 42 Sl. No. 10.2.4Supply, Erection, testing and commissioning of AMF panel suitable for .....kVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for A 4 pole contactor for alternator with thermal O/L relay,. A 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, ....capacity bypass switch and frequency sensing, PCC 1301controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ kVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMF module by pass Mode, Battery charger unit with inbuilt Auto/Manual and Flat/Boost facility. The complete set shall have sufficient safety and adhere to NEC, NBC 2016, IEC, CPWD specifications, PCB norms and KSGEI Acts and Rules.82.5 KVA to 125 KVAEach109531.0109531.01.0FalseNoneNoneFalseNoneFalse109531.00
255449978450NoneKPWD SR 2023-24 Vol VIPage 18 Sl. No. 5.19.13Supplying and fixing regular MCB distribution boards on wall/wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.l - Double Door 8 Way TP & NEach6091.06091.05.0FalseNoneNoneFalseNoneFalse30455.00
255450078450NoneKPWD SR 2023-24 Volume VI Page 18 Sl. No. 5.20.4Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board.32-40A 2 poleEach4559.04559.012.0FalseNoneNoneFalseNoneFalse54708.00
255450178450NoneKPWD SR 2023-24Vol VI Page 2 Sl. No. 1.1.1Open Conduit System Supplying heavy gauge PVC conduit pipe dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or raw plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws19/20 mm dia 2 mm thickMtr69.069.07000.0FalseNoneNoneFalseNoneFalse483000.00
255450278450NoneKPWD SR 2023-24Vol VI Page 2 Sl. No. 1.1.2Open Conduit System Supplying heavy gauge PVC conduit pipe dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or raw plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws25 mm dia 2 mm thickMtr81.081.04750.0FalseNoneNoneFalseNoneFalse384750.00
255450378450NoneKPWD SR 2023-24Vol VI Page 2 Sl. No.1.1.3Open Conduit System Supplying heavy gauge PVC conduit pipe dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or raw plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws 32 mm dia 2.5 mm thickMtr106.0106.0750.0FalseNoneNoneFalseNoneFalse79500.00
255450478450NoneKPWD SR 2023-24Vol VI Page 2 Sl. No. 1.1.4Open Conduit System Supplying heavy gauge PVC conduit pipe dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or raw plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws 40 mm dia 2.5 mm thickMtr149.0149.0500.0FalseNoneNoneFalseNoneFalse74500.00
255450578450NoneKPWD SR 2023-24Vol VI Page 2 Sl. No. 1.2.1Concealed Conduit System Supplying heavy gauge PVC conduit pipe mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20 mm dia 2 mm thickMtr66.066.0200.0FalseNoneNoneFalseNoneFalse13200.00
255450678450NoneKPWD SR 2023-24Vol VI Page 2 Sl. No. 1.2.2Concealed Conduit System Supplying heavy gauge PVC conduit pipe mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25 mm dia 2 mm thickMtr78.078.0150.0FalseNoneNoneFalseNoneFalse11700.00
255450778450NoneKPWD SR 2023-24VolVI Page 2 Sl. No. 1.2.3Concealed Conduit System Supplying heavy gauge PVC conduit pipe mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 32 mm dia 2.5 mm thickMtr103.0103.050.0FalseNoneNoneFalseNoneFalse5150.00
255450878450NoneKPWD SR 2023-2 Vol VI Page 2 Sl. No. 1.3.1Supplying heavy gauge PVC Conduit Pipe .... dia mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.19/20 mm dia 2 mm thickMtr68.068.01000.0FalseNoneNoneFalseNoneFalse68000.00
255450978450NoneKPWD SR 2023-24Vol VI Page 2 Sl. No. 1.3.2Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 25 mm dia 2 mm thickMtr79.079.01250.0FalseNoneNoneFalseNoneFalse98750.00
255451078450NoneKPWD SR 2023-24Vol VI Page 2 Sl. No. 1.3.3Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.32 mm dia 2.5 mm thickMtr99.099.0200.0FalseNoneNoneFalseNoneFalse19800.00
255451178450NoneKPWD SR 2023-24 Volume VI Page 2 Sl. No. 1.5.1Supplying and fixing PVC/metal conduit Deep junction box 19/20 mm deep Junction boxEach49.049.085.0FalseNoneNoneFalseNoneFalse4165.00
255451278450NoneKPWD SR 2023-24VolVI Page 3 Sl. No. 1.5.2Supplying and fixing PVC/metal conduit Deep junction box 25 mm deep Junction boxEach56.056.0500.0FalseNoneNoneFalseNoneFalse28000.00
255451378450NoneKPWD SR 2023-24Vol VI Page 3 Sl. No. 1.5.3Supplying and fixing PVC/metal conduit Deep junction box 32 mm deep Junction boxEach61.061.025.0FalseNoneNoneFalseNoneFalse1525.00
255451478450NoneKPWD SR 2023-24Volume VI Page 3 Sl. No. 1.7.1Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing up to wall surface complete.up to 50 mm conduit in brick wallMtr29.029.0500.0FalseNoneNoneFalseNoneFalse14500.00
255451578450NoneKPWD SR 2023-24 Volume VI Page 3 Sl. No. 1.7.2Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing up to wall surface complete.up to 50 mm conduit CC floorMtr69.069.01500.0FalseNoneNoneFalseNoneFalse103500.00
255451678450NoneKPWD SR 2023-24Vol VI Page 3 Sl.No. 1.8.1Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm as required.20mmMtr28.028.01000.0FalseNoneNoneFalseNoneFalse28000.00
255451778450NoneKPWD SR 2023-24 Vol VI Page 3 Sl.No. 1.8.2Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm as required.25mmMtr35.035.01250.0FalseNoneNoneFalseNoneFalse43750.00
255451878450NoneKPWD SR 2023-24 Vol VI Page 3 Sl.No. 1.8.3Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm as required.32mmMtr43.043.0300.0FalseNoneNoneFalseNoneFalse12900.00
255451978450NoneKPWD SR 2023-24 VolVI Page 3 Sl.No. 1.8.4Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm as required.38mmMtr62.062.0350.0FalseNoneNoneFalseNoneFalse21700.00
255452078450NoneKPWD SR 2023-24Vol VI Page 3 Sl.No. 1.8.5Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm as required.50mmMtr43.043.0500.0FalseNoneNoneFalseNoneFalse21500.00
255452178450NoneKPWD SR 2023-24 Vol VI Page 3Sl. No. 1.9.1Supplying PVC flexible conduit pipe mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely 20 mmMtr19.019.01500.0FalseNoneNoneFalseNoneFalse28500.00
255452278450NoneKPWD SR 2023-24 Vol VI Page 3Sl. No. 1.9.2Supplying PVC flexible conduit pipe mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely 25 mmMtr22.022.01000.0FalseNoneNoneFalseNoneFalse22000.00
255452378450NoneKPWD SR 2023-24 Vol VI Page 3Sl. No. 1.9.3Supplying PVC flexible conduit pipe mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely 32 mmMtr29.029.0100.0FalseNoneNoneFalseNoneFalse2900.00
255452478450NoneKPWD SR 2023-24 Vol VI Page 3Sl. No. 1.9.4Supplying PVC flexible conduit pipe mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely 40 mmMtr36.036.0100.0FalseNoneNoneFalseNoneFalse3600.00
255452578450NoneKPWD SR 2023-24 Vol VI Page 3Sl. No. 1.9.5Supplying PVC flexible conduit pipe mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely 50 mmMtr47.047.0100.0FalseNoneNoneFalseNoneFalse4700.00
255452678450NoneKPWD SR 2023-24 Vol VIPage 3 Sl. No. 1.11Supplying And Fixing "S" Hook made out of 14 mm dia M.S. RodNos52.052.035.0FalseNoneNoneFalseNoneFalse1820.00
255452778450NoneKPWD SR 2023-24 Volume VI Page 4 Sl. No. 1.12Supplying And Fixing M.S. Rafter Clamp Set made out of M.S. Flat & 14 mm M.S. rod.Nos160.0160.035.0FalseNoneNoneFalseNoneFalse5600.00
255452878450NoneKPWD SR 2023-24 Vol VI Page 4 Sl.No.1.13Supplying And Fixing Metal Fan Box with Round Hook.Nos117.0117.035.0FalseNoneNoneFalseNoneFalse4095.00
255452978450NoneKPWD SR 2023-24 Volu VI Page5 Sl. No.2.1.1WIRES & CABLES Point wiring using Copper wire with switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point up to 3Mtr from tapping point to out let via switchPoint285.0285.050.0FalseNoneNoneFalseNoneFalse14250.00
255453078450NoneKPWD SR 2023-24Volume VI Page 5 Sl. No.2.1.2WIRES & CABLES Point wiring using Copper wire with switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Medium point above 3Mtr up to 6Mtr from tapping point to out let via switchPoint394.0394.050.0FalseNoneNoneFalseNoneFalse19700.00
255453178450NoneKPWD SR 2023-24Vol VI Page 5 Sl. No.2.1.3WIRES & CABLES Point wiring using Copper wire with switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Long point above 6Mtr up to 10Mtr from tapping point to out let via switchPoint570.0570.0125.0FalseNoneNoneFalseNoneFalse71250.00
255453278450NoneKPWD SR 2023-24 Volume VI Page 5 Sl. No.2.1.4WIRES & CABLES Point wiring using Copper wire with switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switchesPoint708.0708.0150.0FalseNoneNoneFalseNoneFalse106200.00
255453378450NoneKPWD SR 2023-24 Volume VI Page 5 Sl. No.2.1.5WIRES & CABLES Point wiring using Copper wire with switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Three outlet in a row, above 6Mts up to 10Mtr from tapping point to out let via switchesPoint1035.01035.0100.0FalseNoneNoneFalseNoneFalse103500.00
255453478450NoneKPWD SR 2023-24Volume VI Page 5 Sl. No.2.2.5Three outlet in a row, above 6Mts up to 10Mtr from tapping point to out let via switches boxPoint989.0989.025.0FalseNoneNoneFalseNoneFalse24725.00
255453578450NoneKPWD SR 2023-24 Volu VI Page 5Sl. No.2.3.1Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1 mm2Mtr19.019.02500.0FalseNoneNoneFalseNoneFalse47500.00
255453678450NoneKPWD SR 2023-24 Vol VI Page 5Sl. No.2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2011 1.5 mm2Mtr26.026.04000.0FalseNoneNoneFalseNoneFalse104000.00
255453778450NoneKPWD SR 2023-24Vol VI Page 5Sl. No.2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2012 2.5 mm2Mtr42.042.04200.0FalseNoneNoneFalseNoneFalse176400.00
255453878450NoneKPWD SR 2023-24 Vol VI Page 5Sl. No.2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2013 4 mm2Mtr63.063.03000.0FalseNoneNoneFalseNoneFalse189000.00
255453978450NoneKPWD SR 2023-24 Vol VI Page 5Sl. No.2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2014 6 mm2Mtr92.092.02500.0FalseNoneNoneFalseNoneFalse230000.00
255454078450NoneKPWD SR 2023-24 VI Page 6Sl. No.2.3.6Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2015 10 mm2Mtr167.0167.0600.0FalseNoneNoneFalseNoneFalse100200.00
255454178450NoneKPWD SR 2023-24Vol VI Page 6Sl. No.2.3.7Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2016 16 mm2Mtr318.0318.0800.0FalseNoneNoneFalseNoneFalse254400.00
255454278450NoneKPWD SR 2023-24Vol VIPage 6 Sl. No.2.5.2Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage up to 1100 Volts as per IS-694:1990 3C x 1.5 mm2Mtr72.072.01000.0FalseNoneNoneFalseNoneFalse72000.00
255454378450NoneKPWD SR 2023-24Vol VIPage 6 Sl. No.2.5.8Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage up to 1100 Volts as per IS-694:1990 3C x 2.5 mm2Mtr113.0113.01000.0FalseNoneNoneFalseNoneFalse113000.00
255454478450NoneKPWD SR 2023-24Vol VIPage 6 Sl. No.2.5.15Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage up to 1100 Volts as per IS-694:1990 3C x 4 mm2Mtr172.0172.01000.0FalseNoneNoneFalseNoneFalse172000.00
255454578450NonePWD SR 2023-24 Vol VIPage 7 Sl. No.2.6.1Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage up to 1100 Volts as per IS-694:1990.3C x 2.5 mm2Mtr117.0117.0200.0FalseNoneNoneFalseNoneFalse23400.00
255454678450NoneKPWD SR 2023-24 Volume VIPage 7 Sl. No.2.6.2Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage up to 1100 Volts as per IS-694:1990.3C x 4 mm2Mtr168.0168.0200.0FalseNoneNoneFalseNoneFalse33600.00
255454778450NoneKPWD SR 2023-24 Volume VIPage 8 Sl. No.3.2Supplying and mounting 2 Nos. of 2Way 6 A flush type switches either surface/flush mounted on existing gang box or in 4mm thick plastic sheet and mounted on a flush mounted wooden box and wiring as per IS 3854Each170.0170.040.0FalseNoneNoneFalseNoneFalse6800.00
255454878450NoneKPWD SR 2023-24 Volume VI Page 8Sl. No.3.3.1Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.1-2 WayEach103.0103.0125.0FalseNoneNoneFalseNoneFalse12875.00
255454978450NoneKPWD SR2023-24 Volume VI Page 8Sl. No.3.3.2Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.3 WayEach124.0124.050.0FalseNoneNoneFalseNoneFalse6200.00
255455078450NoneKPWD SR2023-24 Volume VI Page 8Sl. No.3.3.3Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.4-5 WayEach137.0137.025.0FalseNoneNoneFalseNoneFalse3425.00
255455178450NoneKPWD SR2023-24 Volume VI Page 8Sl. No.3.3.4Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.6 WayEach173.0173.015.0FalseNoneNoneFalseNoneFalse2595.00
255455278450NoneKPWD SR2023-24 Volume VI Page 8Sl. No.3.3.5Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.8 WayEach219.0219.030.0FalseNoneNoneFalseNoneFalse6570.00
255455378450NoneKPWD SR2023-24 Volume VI Page8 Sl. No.3.3.6Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.10-12 WayEach261.0261.020.0FalseNoneNoneFalseNoneFalse5220.00
255455478450NoneKPWD SR2023-24 Volume VI Page 8Sl. No.3.3.7Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.16 WayEach294.0294.010.0FalseNoneNoneFalseNoneFalse2940.00
255455578450NoneKPWD SR2023-24 Volume VI Page 8Sl. No.3.3.8Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.18 WayEach339.0339.015.0FalseNoneNoneFalseNoneFalse5085.00
255455678450NoneKPWD SR2023-24 Volume VI Page 8Sl. No.3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-2 WayEach138.0138.050.0FalseNoneNoneFalseNoneFalse6900.00
255455778450NoneKPWD SR2023-24 Volume VI Page 8Sl. No.3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3 WayEach159.0159.025.0FalseNoneNoneFalseNoneFalse3975.00
255455878450NoneKPWD SR2023-24 Volume VI Page 8Sl. No.3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5 WayEach177.0177.010.0FalseNoneNoneFalseNoneFalse1770.00
255455978450NoneKPWD SR2023-24 Volume VI Page 8Sl. No.3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6 WayEach220.0220.05.0FalseNoneNoneFalseNoneFalse1100.00
255456078450NoneKPWD SR2023-24 Volume VI Page 8Sl. No.3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 WayEach261.0261.020.0FalseNoneNoneFalseNoneFalse5220.00
255456178450NoneKPWD SR2023-24Volume VI Page8 Sl. No.3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12 WayEach319.0319.015.0FalseNoneNoneFalseNoneFalse4785.00
255456278450NoneKPWD SR2023-24 Volume VI Page 8Sl. No.3.4.7Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 16 WayEach363.0363.05.0FalseNoneNoneFalseNoneFalse1815.00
255456378450NoneKPWD SR2023-24 Volume VI Page 8Sl. No.3.4.8Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 18 WayEach405.0405.05.0FalseNoneNoneFalseNoneFalse2025.00
255456478450NoneKPWD SR2023-24 Volume VI Page 8Sl. No.3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 1-2 WayEach137.0137.0150.0FalseNoneNoneFalseNoneFalse20550.00
255456578450NoneKPWD SR2023-24 Volume VI Page 8Sl. No.3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 3 WayEach161.0161.0100.0FalseNoneNoneFalseNoneFalse16100.00
255456678450NoneKPWD SR2023-24 Volume VI Page 8Sl. No.3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 4-5 WayEach175.0175.035.0FalseNoneNoneFalseNoneFalse6125.00
255456778450NoneKPWD SR2023-24 Volume VI Page 8Sl. No.3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 6 WayEach234.0234.020.0FalseNoneNoneFalseNoneFalse4680.00
255456878450NoneKPWD SR2023-24 Volume VI Page 8Sl. No.3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 8 WayEach284.0284.050.0FalseNoneNoneFalseNoneFalse14200.00
255456978450NoneKPWD SR2023-24 Volume VI Page 8Sl. No.3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 10-12 WayEach344.0344.035.0FalseNoneNoneFalseNoneFalse12040.00
255457078450NoneKPWD SR2023-24 Volume VI Page 8Sl. No.3.5.7Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 16 WayEach397.0397.015.0FalseNoneNoneFalseNoneFalse5955.00
255457178450NoneKPWD SR2023-24 Volume VI Page 8Sl. No.3.5.8Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 18 WayEach457.0457.020.0FalseNoneNoneFalseNoneFalse9140.00
255457278450NoneKPWD SR2023-24Volume VI Page 9 Sl. No.3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A One Way SwitchEach102.0102.0225.0FalseNoneNoneFalseNoneFalse22950.00
255457378450NoneKPWD SR2023-24Volume VI Page 9 Sl. No.3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A Two Way SwitchEach166.0166.020.0FalseNoneNoneFalseNoneFalse3320.00
255457478450NoneKPWD SR2023-24Volume VI Page 9 Sl. No.3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A Three Way socketEach171.0171.0150.0FalseNoneNoneFalseNoneFalse25650.00
255457578450NoneKPWD SR2023-24Volume VI Page 9 Sl. No.3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Stepped Fan Regulator Two ModuleEach357.0357.020.0FalseNoneNoneFalseNoneFalse7140.00
255457678450NoneKPWD SR2023-24Volume VI Page 9 Sl. No.3.6.5Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.400W DimmerEach276.0276.05.0FalseNoneNoneFalseNoneFalse1380.00
255457778450NoneKPWD SR2023-24Volume VI Page 9 Sl. No.3.6.6Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.600W DimmerEach329.0329.05.0FalseNoneNoneFalseNoneFalse1645.00
255457878450NoneKPWD SR2023-24Volume VI Page 9 Sl. No.3.6.7Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.16A One Way SwitchEach180.0180.0125.0FalseNoneNoneFalseNoneFalse22500.00
255457978450NoneKPWD SR2023-24Volume VI Page 9 Sl. No.3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A Bell PushEach177.0177.04.0FalseNoneNoneFalseNoneFalse708.00
255458078450NoneKPWD SR2023-24Volume VI Page 9 Sl. No.3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.32A DP SwitchEach326.0326.04.0FalseNoneNoneFalseNoneFalse1304.00
255458178450NoneKPWD SR2023-24Volume VI Page 9 Sl. No.3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6/16A Universal SocketEach236.0236.0125.0FalseNoneNoneFalseNoneFalse29500.00
255458278450NoneKPWD SR2023-24Volume VI Page 9 Sl. No.3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.TV/Telephone SocketEach156.0156.015.0FalseNoneNoneFalseNoneFalse2340.00
255458378450NoneKPWD SR2023-24Volume VI Page 9 Sl. No.3.6.12Supplying and fixing of modular switch AND connected accessories on existing modular switch plate as per IS 3854 and IS 1293.RJ45/I.O Outlet Cat-6Each337.0337.020.0FalseNoneNoneFalseNoneFalse6740.00
255458478450NoneKPWD SR2023-24 Volume VIPage 9 Sl. No.3.9Supplying and fixing hilum plastic sheet 3mm thick with necessary notches for fixing switches, regulators etc., and fixing on existing wood or metal box using N. F. screws.cm0.350.3535000.0FalseNoneNoneFalseNoneFalse12250.00
255458578450NoneKPWD SR2023-24 Volume VI Page9 Sl. No.3.10.2Supplying 4 mm thick white plastic plate and covering for junction boxes of size mm conduit using necessary machine screws.80/90 mmNo15.015.0500.0FalseNoneNoneFalseNoneFalse7500.00
255458678450NoneKPWD SR2023-24Volume VI Page 9Sl. No.3.10.3Supplying 4 mm thick white plastic plate and covering for junction boxes of size mm conduit using necessary machine screws.110 mmNo21.021.050.0FalseNoneNoneFalseNoneFalse1050.00
255458778450NoneKPWD SR2023-24 Volume VI Page 43 Sl. No.11.3.3Supplying of feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V at 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 4' 36/40 WEach1269.01269.0130.0FalseNoneNoneFalseNoneFalse164970.00
255458878450NoneKPWD SR2023-24 Volume VI Page 44 Sl. No.11.5.1Supply of round/square recess/surface mounted rolling type LED Down light with W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector and has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @50/60Hz & Power factor greater than 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 5-6WEach571.0571.0150.0FalseNoneNoneFalseNoneFalse85650.00
255458978450NoneKPWD SR2023-24 Volume VI Page 44 Sl. No.11.5.2Supply of round/square recess/surface mounted rolling type LED Down light with W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours and 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V at 50/60Hz & Power factor greater than 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12WEach885.0885.050.0FalseNoneNoneFalseNoneFalse44250.00
255459078450NoneKPWD SR2023-24 Volume VI Page 44 Sl. No.11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V at 50/60Hz & Power factor greater than 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18WEach1324.01324.0125.0FalseNoneNoneFalseNoneFalse165500.00
255459178450NoneKPWD SR2023-24Volume VI Page 30 Sl. No.6.2.2LED Post Top Lantern Garden Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 15" Sweep (450 mm)Each4446.04446.010.0FalseNoneNoneFalseNoneFalse44460.00
255459278450NoneKPWD SR2023-24 Volume VI Page 30 Sl. No.6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.48" Sweep (1200 mm) Regular modelEach2984.02984.020.0FalseNoneNoneFalseNoneFalse59680.00
255459378450NoneKPWD SR2023-24 Volume VIPage 30 Sl. No.6.5.2Supplying wall mounting fan suitable to operate at single- phase 230v AC. supply. 400 mm SweepEach3212.03212.065.0FalseNoneNoneFalseNoneFalse208780.00
255459478450NoneKPWD SR2023-24Volume VI Page 30 Sl. No.11.9.4LED Flood LIGHT Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System Power consumption. LED Efficiency greater than 1301m/w, nominal CRI greater than 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under LED Floodlight 150WNos12490.012490.015.0FalseNoneNoneFalseNoneFalse187350.00
255459578450NoneKPWD SR 2023-24Volume VI Page 11 Sl. No.4.2.7Fabricating, supplying and erection of ... ms long hot dip Galvanized Octagonal hot dip Pole with BSEN 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for m Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom ..... mm , top. mm with 3 mm thick, suitable base plate and 4Nos of long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc., (excluding foundation) as per drawing appended.9 m - Top 70 mm and Bottom 155 mm diaEach19500.019500.015.0FalseNoneNoneFalseNoneFalse292500.00
255459678450NoneKPWD SR2023-24Volume VI Page 46 Sl. No.11.8.4LED STREET LIGHT Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency greater than 1301m/w, nominal CRI greater than 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on LED Streetlight 90 WNos8860.08860.015.0FalseNoneNoneFalseNoneFalse132900.00
255459778450NoneKPWD SR2023-24 Volume VI Page 48 Sl.No.12.1Supplying and fixing one of 230 V bell or buzzer and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws.Each189.0189.02.0FalseNoneNoneFalseNoneFalse378.00
255459878450NoneKPWD SR2023-24Volume VIPage 48 Sl. No.12.2.1Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on Ding Dong BellEach246.0246.02.0FalseNoneNoneFalseNoneFalse492.00
255459978450NoneKPWD SR2023-24Volume VI Page 56Sl. No.13.5Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wiresEach162.0162.015.0FalseNoneNoneFalseNoneFalse2430.00
255460078450NoneKPWD SR2023-24Volume VI Page 56 Sl.No.13.6Fixing charges of post top/ Gate/ Garden fitting /LED on the existing CI/ GI or any other pipe using required size of reducer, wiring using suitable wires.Each198.0198.030.0FalseNoneNoneFalseNoneFalse5940.00
255460178450NoneKPWD SR 2023-24Volume VI Page 56 Sl. No.13.7.1Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps.On wall/ ceiling / Rafter / GirdersEach122.0122.0500.0FalseNoneNoneFalseNoneFalse61000.00
255460278450NoneKPWD SR 2023-24Volume VI Page 56 Sl. No.13.7.2Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps.Using necessary length of G.I. chainEach263.0263.0110.0FalseNoneNoneFalseNoneFalse28930.00
255460378450NoneKPWD SR 2023-24 Volume VI Page 57 Sl. No.13.10Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each171.0171.085.0FalseNoneNoneFalseNoneFalse14535.00
255460478450NoneKPWD SR2023-24Volume VI Page 57 Sl. No.13.11Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.Each315.0315.010.0FalseNoneNoneFalseNoneFalse3150.00
255460578450NoneKPWD SR2023-24 Volume VI Page57 Sl. No.13.12Extra length of GI pipe of class B 19mm dia for down rod.Each197.0197.020.0FalseNoneNoneFalseNoneFalse3940.00
255460678450NoneKPWD SR2023-24Volume VI Page 57Sl. No.13.13Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.Each707.0707.012.0FalseNoneNoneFalseNoneFalse8484.00
255460778450NoneKPWD SR2023-24Volume VI Page 57Sl. No.13.19Fixing all types and all capacities of 1'x4' / 2'x2' LED Light fittings indoor on the wall / ceiling / rafters / girders with necessary supporting frame, using 2310.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps.Each490.0490.020.0FalseNoneNoneFalseNoneFalse9800.00
255460878450NoneKPWD SR 2023-24Volume VI Page 36 Sl. No.8.1TELEPHONE/TV/CCTV SYSTEM NETWORKING  AND TELECOMUNICATION Supplying and drawing UTP-CAT 6E LAN cable.m34.034.06500.0FalseNoneNoneFalseNoneFalse221000.00
255460978450NoneKPWD SR2023-24Volume VI Page 36Sl. No.8.2.3Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable 3 Pairm28.028.01250.0FalseNoneNoneFalseNoneFalse35000.00
255461078450NoneKPWD SR2023-24Volume VI Page 36 Sl.No.8.3Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6.m44.044.018.0FalseNoneNoneFalseNoneFalse792.00
255461178450NoneKPWD SR 2023-24Volume VI Page 36 Sl. No.8.4.8Supplying and Fixing of switch mounting rack with power manager & Cable manager.32U with 650mm depthEach36212.036212.01.0FalseNoneNoneFalseNoneFalse36212.00
255461278450NoneKPWD SR 2023-24Volume VI Page 36 Sl. No.8.4.8Supplying and Fixing of Power stripEach1457.01457.01.0FalseNoneNoneFalseNoneFalse1457.00
255461378450NoneKPWD SR2023-24 VolumeVI Page 36 Sl. No.8.6Supplying of shelfEach827.0827.06.0FalseNoneNoneFalseNoneFalse4962.00
255461478450NoneKPWD SR 2023-24Volume VI Page 36 Sl. No.8.9.4Supplying fixing of Network Switches 48 port 10/100 SwitchEach15000.015000.01.0FalseNoneNoneFalseNoneFalse15000.00
255461578450NoneKPWD SR2023-24 Volume VI Page37 Sl. No.8.10.2Supplying and fixing of I/O socket with back box Double I/OEach550.0550.015.0FalseNoneNoneFalseNoneFalse8250.00
255461678450NoneKPWD SR2023- 24 Volume VI Page 37 Sl.No.8.11.3Supplying and Fixing of ... ms Cat 6 Patch Cable 3 mEach331.0331.030.0FalseNoneNoneFalseNoneFalse9930.00
255461778450NoneKPWD SR2023-24Volume VI Page 37 Sl. No.8.12.1Supplying AND Fixing of Patch panel for LAN cabling 48 Port 10/100 patch panelEach14120.014120.01.0FalseNoneNoneFalseNoneFalse14120.00
255461878450NoneKPWD SR2023-24Volume VI Page 37Sl. No.8.13.2Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination.20 Pairm383.0383.01.0FalseNoneNoneFalseNoneFalse383.00
255461978450NoneKPWD SR2023-24Volume VI Page 38 Sl. No.9.2.1Supplying, erecting, testing and commissioning of OFF- LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with all accessories complete and Excluding batteries and wiring complete.1 kVA OFF LINE UPSEach15087.015087.02.0FalseNoneNoneFalseNoneFalse30174.00
255462078450NoneKPWD SR2023-24Volume VI Page 38 Sl. No.9.2.2Supplying, erecting, testing and commissioning of OFF- LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with all accessories complete and Excluding batteries and wiring complete.2 kVA OFF LINE UPSEach21293.021293.01.0FalseNoneNoneFalseNoneFalse21293.00
255462178450NoneKPWD SR2023-24Volume VI Page 38 Sl. No.9.2.3Supplying, erecting, testing and commissioning of OFF- LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with all accessories complete and Excluding batteries and wiring complete 3 kVA OFF LINE UPSEach29142.029142.01.0FalseNoneNoneFalseNoneFalse29142.00
255462278450NoneKPWD SR2023-24 Volume VIPage 39 Sl. No.9.5.4Supplying, installation, testing and commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries.42 AH capacityEach5092.05092.04.0FalseNoneNoneFalseNoneFalse20368.00
255462378450NoneKPWD SR2023-24 Volume VIPage 39 Sl. No.9.5.6Supplying, installation, testing and commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries.75/80 AH capacityEach10172.010172.06.0FalseNoneNoneFalseNoneFalse61032.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17077338700000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17077338700000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17077338700000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17077356360000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17077356760000NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of e-Procurement portal due to internet connectivity issues and technical glitches at bidders end.None
17077358030000NoneNoneELIGIBILITYThe employer is not responsible for any delay in accessing E-procurement portal.None
17077358770000NoneNoneELIGIBILITYConditional tenders are not acceptedNone
17077358920000NoneNoneELIGIBILITYThe employer reserves the right to reject one and all tenders without assigning any reason there of.None
17077359230000NoneNoneELIGIBILITYTo qualify for award of this contract, each tenderer should give all details and documents as per Technical and Financial bid attached to this tenderNone
17077359470000NoneNoneELIGIBILITYAs per Karnataka state Government order LD/300/LET/2006 Blore dated 01.01.07 and Government letter no PW/134/BMS/2007 dated 27.07.07, a sum amounting to 1% of the bill amount will be deducted towards constructions labour welfare fundNone
17077360040000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete manner otherwise it will be rejectedNone
17077360200000NoneNoneELIGIBILITYAll scanned documents to be uploaded shall be in original and the Executive Engineer reserves the right to verify the documents before approval.None
17077362400000NoneNoneELIGIBILITYThe tenderer should submit the Registration Certificate along with technical bid.None
17077362590000NoneNoneELIGIBILITYOriginal documents/ Certificates enclosed must be produced in the office of Executive Engineer at the time of opening of technical bid.None
17077362760000NoneNoneELIGIBILITYAll the items in the tender are inclusive of cost and conveyance of all materials, all lead ,lift, loading, unloading, transportation, labour, hire chares of machinery , curing for concrete worksNone
17077362910000NoneNoneELIGIBILITYContractors should follow strictly prevailing rules of labour actNone
17077363100000NoneNoneELIGIBILITYIn case of the death of a contractor, after executing the agreement / commencement of the work, his legal heir, is an eligible registered contractor and is willing, can execute and complete the work, at the accepted tender rates, irrespective of the cost of the workNone
17077363200000NoneNoneELIGIBILITYDepartment will not supply any materialsNone
17077363440000NoneNoneELIGIBILITYThe tenderer should submit proposed methodology and programme of construction backed with equipment and material planning, & deployment duly supported with broad calculation and quality management , plan, proposed to be adopted justifying their capability of execution and completion of the work as per technical specifications and within the stipulated period of completionNone
17077364700000NoneNoneELIGIBILITYThe contractor should maintain the work for the period of 1 years (One years) after the completion of the work at his own costNone
17077364870000NoneNoneELIGIBILITYThe intending contractors are requested to note that they should abide by the detailed instructions and conditions contained in the Standard Bid document KW- IV.None
17077365310000NoneNoneELIGIBILITYPayment of EMD of Rs100000 shall be through E payment and remaining amount through the Bank Guarantee Banker s Cheque/Demand Draft/Pay Order,in favour of Executive Engineer,and shall be valid for 90 days beyond the validity of tender.None
17077365520000NoneNoneELIGIBILITYThe tenderer should bear all cost associated with the preparation and submission of his tender and the employer will in no case be resposble and liable for those cost. The cost of the tender form shall not be refundableNone
17077365760000NoneNoneELIGIBILITYTo qualify award of this contract the tenderer should submit proof of work qualification, for having executed similar nature of works, costing not less than 50 % of the value of work.None
17077366030000NoneNoneELIGIBILITYMaterials like Bitumen, steel,cement etc., required for the work shall be procured by the tenderer themselves and should get tested by the quality control authority before used on the work.None
17077366390001NoneNoneELIGIBILITYPERFORMANCE SECURITY The successful tenderer shall furnish Performance Security Deposit (Achievement Guarantee ) at 5% of the contract price plus additional security for unbalanced tender with in 20 days after approve of tender as per rule 25.5 of the tender and clause 44 of the agreement in the form of cash/Bankers Cheque, D.D,Pay order Bank Guarantee, in the nature of EXECUTIVE ENGINEER,PWD Udupi Div.None
17077366760000NoneNoneELIGIBILITYContractors should be registered with KPWD Class I Registration and the tenderer should submit the Registration Certificate along with technical bid.None
17077366970000NoneNoneELIGIBILITYIncrease in GST shall not be paid in the extended period of contract for which the contractor alone is responsible for delay as determined by the authority while granting the extension of time.None
17077367220000NoneNoneELIGIBILITYAny tender aggrieved by an order passed by the tender accepting authority other than the government under section 13 may appeal through Karnataka Public Procurement Portal only. written appeals will not be accepted.None
17077369280000NoneNoneELIGIBILITYSteel Centering and Steel Scaffolding shall be used for all centering and scaffolding formworks where ever necessary as per specification of Schedule of Rates.None
17077371370000NoneNoneELIGIBILITYThe contractor shall visit the construction site along with shilpi and go through the detail drawings of the work and Module of Temple and contractor shall submit a letter of visit from the Chief executive officer or President of temple development committee of of the temple along with all the tender document without fail.(Special Condition as per request of Temple Authority vide letter dated:30.01.2024)None
17077371580000NoneNoneELIGIBILITYThe tenderer should submit proposed methodology and programe of construction backed with equipment and material planning, & deployment duly supported with broad calculation and quality management , plan, proposed to be adopted justifying their capability of execution and completion of the work as per technical specifications and within the stipulated period of completionNone
17077371880000NoneNoneELIGIBILITYThe tenderer should Submit a concurrence letter regarding executing carving Stone for this work from atlest 2 Skilled person.None
17077373890000NoneNoneELIGIBILITYEstimate rates are excluding GST as per Common SR 2023-24 and prevailing GST (18% of Amount Put to tender) amount is kept in form of Lump sum in sanctioned estimate according to guidelines in Common SR (GO:PWD 51 RDF 2019 Bangaluru Dt:18.03.2022). Therefore, amount put to Tender and ECV amount are excluding GST. Hence, GST will be paid separately for S.R Item Only the quoted amount accordingly. Declaration Certificate must be attached mandatorily.None
17077387600000NoneNoneELIGIBILITYG.S.T shall be paid Separately for all items considered under Civil Works (excluding GST) and Electrical items only.None
17077387720000NoneNoneELIGIBILITYG.S.T shall not be paid Separately for all items considered under Civil Works (including GST) items as the data rates are approved with inclusive of all kinds of statutory taxes. Hence, non of the taxes will be paid separately .None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneSection 2: ITT 3.2 - To qualify for award of this contract, each Tenderer in its name should have in the last five years (i.e. 2018-19 to 2022-23) -(b) Satisfactorily completed as prime contractor, at least one similar work such as Temple construction work of value not less than Rs.465.58LakhsPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work-done certificate from not below the rank of Executive Engineer or equivalent
NoneNoneNoneNoneSection 2: ITT 3.2 - To qualify for award of this contract, each Tenderer in its name should have in the last five years (i.e. 2018-19 to 2022-23) -(d) Tenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrification works and should have executed similar electrical works totalng Rs. 44.07lakh(not less than 50% of electrical works) in any one yearPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work-done certificate from not below the rank of Executive Engineer or equivalent
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work-done certificate from not below the rank of Executive Engineer or equivalent
NoneNoneNoneNoneSection 2: ITT 3.2-To qualify for award of this contract, each Tenderer in its name should have in the last five years (i.e. 2018-19 to 2022-23)-(c) executed in any one year, the following minimum quantities of work: -1. Four line dressed Carved Stone Work in foundation/ Basement/ Walls -475.00 cum, 2. Four line dressed carved Stone windows-30.00 No, 3. RCC/PCC-441.00 cum, 4.SSM/ Latrite/ BBM Masonary-298.00cum, 5.TMT Steel-26.00 t, 6.Flooring /Wall cladding-2099.00 sqm, 7.Steel Truss-31336.00kgCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work-done certificate from not below the rank of Executive Engineer or equivalent
NoneNoneNoneNoneSection 2:ITT 3-Each Tenderer should further demonstrate-(a) Machineries to be owned- 1. Concrete mixture machine-1 No, 2.Tipper -3 Nos,3) Water Tank 5,000.00 liters Capacity- 1 NoCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- RC issued by RTO or Sale Deed or Purchase Invoice
NoneNoneNoneNoneInformation on works for which Tenders have been submitted and works which are yet to be completed as on the date of this Tender -A) Existing commitments and on-going works.List of existing commitments and ongoing worksCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Attach details in prescribed format in 1.5(A) Section
NoneNoneNoneNoneInformation on works for which Tenders have been submitted and works which are yet to be completed as on the date of this Tender -(B) Works for which Tenders already submitted.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Attach details in prescribed format in 1.5(B) Section
NoneNoneNoneNoneTenderer Section 2: ITT 3.3-Each Tenderer should further demonstrate: (b) Machineries could be on Lease/Hire/Ownership:1) Self Loaded Concrete mixer-1 No, 2) Excavator / JCB-1 No,3) Tipper -3 Nos, 4) Self operating lift-1 No, 5) Steel Centering/ Scaffolding Materials -500sqm No, 6) Crane 10 M.T Capacity -1No.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- RC issued by RTO or Sale Deed or Purchase Invoice
NoneNoneNoneNoneThe bidder should be a Class-I KPWD contractor.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Attach Contractor Registeration Certificate here
NoneNoneNoneNoneThe tenderer should submit proposed methodology and programme of construction backed with equipment and material planning, & deployment duly supported with broad calculation and quality management , plan, proposed to be adopted justifying their capability of execution and completion of the work as per technical specifications and within the stipulated period of completionCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Attach Bar Chat for 12 months of working Period
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awarded. Also provide the Organisation Chart.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Organisation Chart & Company Profile/PERT
NoneNoneNoneNoneSection 2: ITT 3.2-To qualify for award of this contract, each Tenderer in its name should have in the last five years (i.e.2018-19 to 2022-23) -(a) ) achieved in at least two financial year, a minimum financial turn over (in all classes of civil engineering construction works only) Rs1862.31LakhsFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Attach Turnover Certificate from Registered Chartered Accountant along with profit and loss statement and Balance sheets
NoneNoneNoneNoneSection 2: ITT 3.3 - Each Tenderer should further demonstrate : (b) Liquid assets and /or availability of credit facilities of no less than Rs. 279.35 Lakhs (Credit lines/ letter of credit/ certificates from nationalised/ scheduled banks in prescribed format for meeting the fund requirement etc.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Certificates from Nationalised banks for meeting the fund requirement Credit Lines/Letter of Credit
NoneNoneNoneNoneBanker Details for reference with GST and Pan NumberFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Company Registration Certificate / Contractor regestration certificateTrueTechnical Bid
The contractor shall visit the construction site along with shilpi and go through the detail drawings of the work and Module of Temple and contractor shall submit a letter of visit from the Chief executive officer or President of temple development committee of of the temple along with all the tender document without fail.TrueTechnical Bid
The tenderer should Submit a concurrence letter regarding executing carving Stone for this work from atlest 2 Skilled person.TrueTechnical Bid
Attach GST declaration certificate in the prescribed formatTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1707904740000
version0
createdDateNone
modifiedDateNone
blockNumberO/O Executive Engineer, PWD Division, Udupi
streetNone
cityUdupi
stateKARNATAKA
pin572101
tenderRecallDTONone