1708074161000 | 0 | None | None | Other Works | Construction of Synik Theme Park at Sandeep Unnikrishnan Road 208 SFS in Chowdeshwari ward No 02 at Yelahanka Assembly Constituency | 43561601.58 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2645651 | 82436 | None | code01 | Clearing and grubbing road land including uprooting rank vegetation, grass bushes shrubs saplings and trees girth up to 300 mm removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned including removal and disposal of top organic soil not exceeding 150 mm in thickness. ii By Mechanical Means using Dozer B. In area of thorny jungle. | 100 Sqm | 532.4 | 532.4 | 68.75 | False | None | None | False | None | False | 36602.5 | 0 | 2645652 | 82436 | None | code02 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. | Cum | 104.5 | 104.5 | 3403.125 | False | None | None | False | None | False | 355626.5625 | 0 | 2645653 | 82436 | None | code03 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. | Cum | 397.1 | 397.1 | 739.1595 | False | None | None | False | None | False | 293520.23745 | 0 | 2645654 | 82436 | None | code04 | Cost of Haulage Excluding Loading and Unloading Taking output 18 t load and lead 10 km = 180 t.km. | T.Km | 70.4 | 70.4 | 5302.1241 | False | None | None | False | None | False | 373269.53664 | 0 | 2645655 | 82436 | None | code05 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface ofconsolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | Sqm | 129.8 | 129.8 | 776.0 | False | None | None | False | None | False | 100724.8 | 0 | 2645656 | 82436 | None | code06 | Providing and Filling in foundation with granite / trap broken metal 100mm. and down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications. | Cum | 2950.2 | 2950.2 | 743.6239 | False | None | None | False | None | False | 2193839.22978 | 0 | 2645657 | 82436 | None | code07 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 7044.4 | 7044.4 | 677.997 | False | None | None | False | None | False | 4776082.0668 | 0 | 2645658 | 82436 | None | code08 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 7027.9 | 7027.9 | 417.1529 | False | None | None | False | None | False | 2931708.86591 | 0 | 2645659 | 82436 | None | code09 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/ trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-Footings | Cum | 7089.98 | 7089.98 | 9.2339 | False | None | None | False | None | False | 65468.166322 | 0 | 2645660 | 82436 | None | code10 | Column upto Plinth Beam | Cum | 11160.15 | 11160.15 | 1.89 | False | None | None | False | None | False | 21092.6835 | 0 | 2645661 | 82436 | None | code11 | Skating Flooring | Cum | 6955.3 | 6955.3 | 91.0 | False | None | None | False | None | False | 632932.3 | 0 | 2645662 | 82436 | None | code12 | Plinth Beam | Cum | 9847.2 | 9847.2 | 21.1971 | False | None | None | False | None | False | 208732.08312 | 0 | 2645663 | 82436 | None | code13 | Sump | Cum | 7221.28 | 7221.28 | 98.6521 | False | None | None | False | None | False | 712394.436688 | 0 | 2645664 | 82436 | None | code14 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.-Column | Cum | 11560.34 | 11560.34 | 3.888 | False | None | None | False | None | False | 44946.60192 | 0 | 2645665 | 82436 | None | code15 | Beams | Cum | 10880.32 | 10880.32 | 6.204 | False | None | None | False | None | False | 67501.50528 | 0 | 2645666 | 82436 | None | code16 | Lintel | Cum | 10880.32 | 10880.32 | 2.003 | False | None | None | False | None | False | 21793.28096 | 0 | 2645667 | 82436 | None | code17 | Slab | Cum | 10200.3 | 10200.3 | 19.869 | False | None | None | False | None | False | 202669.7607 | 0 | 2645668 | 82436 | None | code18 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a) Buildings | Tonne | 98402.7 | 98402.7 | 21.3317 | False | None | None | False | None | False | 2099096.87559 | 0 | 2645669 | 82436 | None | code19 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1441.0 | 1441.0 | 275.0365 | False | None | None | False | None | False | 396327.5965 | 0 | 2645670 | 82436 | None | code20 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1354.1 | 1354.1 | 414.0099 | False | None | None | False | None | False | 560610.80559 | 0 | 2645671 | 82436 | None | code21 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 149.6 | 149.6 | 10530.0 | False | None | None | False | None | False | 1575288.0 | 0 | 2645672 | 82436 | None | code22 | Providing and fixing 6mm Clear/opal white/solar bronze/blue/green tinted Multi wall poly carbonate sheet for Tubular structure. The work including cost of all materials, labour charges and usage charges of machinery for cutting, welding, grinding and erection equipments, with all lead, transportation, loading and unloading and all other incidental charges etc. complete as per specification and directions of the Engineer in charge of the work. | Sqm | 3437.5 | 3437.5 | 234.0 | False | None | None | False | None | False | 804375.0 | 0 | 2645673 | 82436 | None | code23 | Providing 20 mm cement plaster with cement mortar 1:3 (1 cement:3 coarse sand) finished with a floating coat of neat cement to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 471.9 | 471.9 | 941.7153 | False | None | None | False | None | False | 444395.45007 | 0 | 2645674 | 82436 | None | code24 | Providing 12 mm cement plaster with Cement mortar 1:3 (1cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 355.3 | 355.3 | 171.75 | False | None | None | False | None | False | 61022.775 | 0 | 2645675 | 82436 | None | code25 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 324.5 | 324.5 | 193.11 | False | None | None | False | None | False | 62664.195 | 0 | 2645676 | 82436 | None | code26 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 110.0 | 110.0 | 171.75 | False | None | None | False | None | False | 18892.5 | 0 | 2645677 | 82436 | None | code27 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 126.5 | 126.5 | 171.75 | False | None | None | False | None | False | 21726.375 | 0 | 2645678 | 82436 | None | code28 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 311.3 | 311.3 | 941.7153 | False | None | None | False | None | False | 293155.97289 | 0 | 2645679 | 82436 | None | code29 | Supplying and filling in plinth with sand under floors, foundation of Bridges including watering, ramming, consolidating and dressing complete. | Cum | 2394.7 | 2394.7 | 69.6706 | False | None | None | False | None | False | 166840.18582 | 0 | 2645680 | 82436 | None | code30 | Providing and laying water proofing treatment to the Water tanks & Liquid Retaining structures with two omponent acrylic polymer modified cementitious waterproofing membrane with minimum elongation of 50% applied @ 1.5 kg/m2 for internal side waterproofing in two layers with waiting period of 4-6 hrs per layer and food grade epoxy coating in two coats certified by CFTRI Mysuru, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 557.7 | 557.7 | 838.2661 | False | None | None | False | None | False | 467501.00397 | 0 | 2645681 | 82436 | None | code31 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 898.7 | 898.7 | 90.16 | False | None | None | False | None | False | 81026.792 | 0 | 2645682 | 82436 | None | code32 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 621.5 | 621.5 | 2160.0 | False | None | None | False | None | False | 1342440.0 | 0 | 2645683 | 82436 | None | code33 | Providing and laying 60mm thick factory made precast M -30 grade Cement Concrete Paver Block as per IRC SP 63:2018 &
IS 15658 for Cycle Tracks & Pedestrian Footpaths of approved shape and colour, laid in required pattern and including over
30mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-incharge. (WMM/WBM Base to be paid separately if necessary as per relevant technical specification) IRC SP63: 2018 | Sqm | 1174.8 | 1174.8 | 808.5 | False | None | None | False | None | False | 949825.8 | 0 | 2645684 | 82436 | None | code34 | Providing and fixing pre cast solid cement concrete Kerb Stones made out of M20 with top and bottom width 114 and 165mm respectively, 400mm high and 450mm in length finished with CM 1:3 plastering and finishing cutting including formwork, curing, including cost of materials, labour charges of machinery, loading, unloading, lead and lift transportion etc., complete as directed by the Engineer in charge of the work. | Nos | 507.0 | 507.0 | 3245.0 | False | None | None | False | None | False | 1645215.0 | 0 | 2645685 | 82436 | None | code35 | Painting Two Coats on New Concrete Surfaces Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concretesurfaces. MORTH Chapter 803 | Sqm | 119.9 | 119.9 | 584.0 | False | None | None | False | None | False | 70021.6 | 0 | 2645686 | 82436 | None | code36 | Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge. | Sqm | 880.0 | 880.0 | 62.94 | False | None | None | False | None | False | 55387.2 | 0 | 2645687 | 82436 | None | code37 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye,River Pink or equivalent. | Sqm | 3137.2 | 3137.2 | 238.405 | False | None | None | False | None | False | 747924.166 | 0 | 2645688 | 82436 | None | code38 | Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. | Sqm | 4736.6 | 4736.6 | 2081.5168 | False | None | None | False | None | False | 9859312.47488 | 0 | 2645689 | 82436 | None | code39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. | Sqm | 1593.9 | 1593.9 | 55.3799 | False | None | None | False | None | False | 88270.02261 | 0 | 2645690 | 82436 | None | code40 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. Ground floor complete with all lead and lift as per the direction of Engineer-In-Charge. | Sqm | 1216.6 | 1216.6 | 128.31 | False | None | None | False | None | False | 156101.946 | 0 | 2645691 | 82436 | None | code41 | Fixing of door frames in an existing opening including embedding frame in floor and walls after cutting masonary for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and downsize granite metal painting two coats of coal tar to sides of frame,making good the damages to walls and floor as required and disposal of the debries with lead upto 50 m. including cost of materials, labour, complete as per specifications. | Nos | 1117.6 | 1117.6 | 3.0 | False | None | None | False | None | False | 3352.8 | 0 | 2645692 | 82436 | None | code42 | Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 151881.4 | 151881.4 | 0.3824 | False | None | None | False | None | False | 58079.44736 | 0 | 2645693 | 82436 | None | code43 | Providing and fixing in position fully panelled Honne wood shutters for doors with , stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) | Sqm | 7793.5 | 7793.5 | 7.56 | False | None | None | False | None | False | 58918.86 | 0 | 2645694 | 82436 | None | code44 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 151.8 | 151.8 | 7.56 | False | None | None | False | None | False | 1147.608 | 0 | 2645695 | 82436 | None | code45 | Providing and fixing Fibre Glass Reinforced Plastic(FRP) Door frames of cross section 90mmx45mm having single rebate of 32mm x15mm to receive shutter of 30 mm thickness.The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat.Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs.the frame shall be covered with fiber glass from all sided M.S.Stay be provided at the bottom to steady the frame | m | 707.3 | 707.3 | 34.3 | False | None | None | False | None | False | 24260.39 | 0 | 2645696 | 82436 | None | code46 | Providing and fixing to existing door frames.30mm thick Fibreglass Reinforced Plastic(F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin,moulded to 3mm thick FRP laminate all round,with suitable wooden blocks inside at required places for fixing of fittings and polurethane foam (PUF)Polystyrene foam to be used as filler material throughout the hollow panel,casted monolithically with testing parameters of F.R.P laminate conforming to table -3 of IS: 14856,complete as per direction of Engineer-in- charge. | Sqm | 3524.4 | 3524.4 | 11.025 | False | None | None | False | None | False | 38856.51 | 0 | 2645697 | 82436 | None | code47 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. | Kg | 201.3 | 201.3 | 126.63 | False | None | None | False | None | False | 25490.619 | 0 | 2645698 | 82436 | None | code48 | Providing & fixing of 3 track x 2 panel sliding windows made out of multi chambered UPVC (Matching to RAL 9016) sections and with minimum TiO2 (Titanium Dioxide) at 6PHR with TPE (Thermo Plastic Elastomer) and lead free gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made). | Sqm | 7407.4 | 7407.4 | 2.88 | False | None | None | False | None | False | 21333.312 | 0 | 2645699 | 82436 | None | code49 | Providing & fixing of louvered ventilator made out of multi chambered UPVC (Matching to RAL 9016) sections and with minimum TiO2 (Titanium Dioxide) at 6PHR with TPE (Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made). | Sqm | 6290.9 | 6290.9 | 3.15 | False | None | None | False | None | False | 19816.335 | 0 | 2645700 | 82436 | None | code50 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 152.9 | 152.9 | 6.0299 | False | None | None | False | None | False | 921.97171 | 0 | 2645701 | 82436 | None | code51 | Providing and placing on terrace(at all floor levels), polyethylene water storage tanks as per IS 12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank(For 1000 litre capacity) | Ltr | 9.9 | 9.9 | 2000.0 | False | None | None | False | None | False | 19800.0 | 0 | 2645702 | 82436 | None | code52 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water, all materials,usage& all other appurtenaces required to complete the work. | Cum | 521.4 | 521.4 | 18.72 | False | None | None | False | None | False | 9760.608 | 0 | 2645703 | 82436 | None | code53 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid complete with all lead and lift as per the direction of Engineer-In-Charge | Each | 6596.7 | 6596.7 | 7.0 | False | None | None | False | None | False | 46176.9 | 0 | 2645704 | 82436 | None | code54 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern | Each | 4899.4 | 4899.4 | 3.0 | False | None | None | False | None | False | 14698.2 | 0 | 2645705 | 82436 | None | code55 | PTMT grating 100 mm dia. | Each | 16.5 | 16.5 | 20.0 | False | None | None | False | None | False | 330.0 | 0 | 2645706 | 82436 | None | code56 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the wallswherever require: White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap | Each | 2579.5 | 2579.5 | 6.0 | False | None | None | False | None | False | 15477.0 | 0 | 2645707 | 82436 | None | code57 | Providing and fixing brass bib cock of approved quality : 20 mm nominal bore. | Nos. | 335.5 | 335.5 | 15.0 | False | None | None | False | None | False | 5032.5 | 0 | 2645708 | 82436 | None | code58 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal bore | Nos. | 345.4 | 345.4 | 4.0 | False | None | None | False | None | False | 1381.6 | 0 | 2645709 | 82436 | None | code59 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of jointscomplete as per direction of Engineer in Charge. External work 20 mm nominal dia Pipes | m | 238.7 | 238.7 | 50.0 | False | None | None | False | None | False | 11935.0 | 0 | 2645710 | 82436 | None | code60 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357mm | Each | 1119.8 | 1119.8 | 7.0 | False | None | None | False | None | False | 7838.6 | 0 | 2645711 | 82436 | None | code61 | Providing and fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10mm gap for thermal expansion, [i] single socketed pipes 100mm diameter | m | 320.1 | 320.1 | 25.0 | False | None | None | False | None | False | 8002.5 | 0 | 2645712 | 82436 | None | code62 | Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments2 HP, Size 50x40 Head 22M, Discharge 186 LPM | Each | 18692.3 | 18692.3 | 1.0 | False | None | None | False | None | False | 18692.3 | 0 | 2645713 | 82436 | None | code63 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 complete with all lead and lift as per the direction of Engineer-In-Charge. | m | 452.1 | 452.1 | 25.0 | False | None | None | False | None | False | 11302.5 | 0 | 2645714 | 82436 | None | code64 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 140mm dia., 6 kg/sqcm & class 3 complete with all lead and lift as per the direction of Engineer-In-Charge | m | 642.4 | 642.4 | 15.0 | False | None | None | False | None | False | 9636.0 | 0 | 2645715 | 82436 | None | code65 | Constructing brick masonry chamber of internal dimension 600x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. | Each | 5270.1 | 5270.1 | 3.0 | False | None | None | False | None | False | 15810.3 | 0 | 2645716 | 82436 | None | code66 | Supplying S&S RCC SPUN / VIBRATED CAST PIPES (REINFORCED) pipes NP-3 Class conforming to IS:458-1988 with latest amentments using ordinary portland cement, for sanitary works and conveying to work site, rolling and lowering into trenches, laying true to line and level including loading and unloading at both destinations and jointing of pipes and specials, perfect linking of joints with jack to correct position including cost of jointing materials, i.e, rubber rings conforming to IS: 5382 for S&S RCC pipes, with all leads and lifts as directed and giving necessary hydraulic test as per ISS to the required pressure and commissioning etc. complete. (Contractor will make his own arrangements for procuring water for testing). Before the execution of the work, the contractor shall carry out the survey. RCC NP3 Class pipe of 600 mm dia. | m | 3454.0 | 3454.0 | 3.9 | False | None | None | False | None | False | 13470.6 | 0 | 2645717 | 82436 | None | code67 | Supplying S&S RCC SPUN / VIBRATED CAST PIPES (REINFORCED) pipes NP-3 Class conforming to IS:458-1988 with latest amentments using ordinary portland cement, for sanitary works and conveying to work site, rolling and lowering into trenches, laying true to line and level including loading and unloading at both destinations and jointing of pipes and specials, perfect linking of joints with jack to correct position including cost of jointing materials, i.e, rubber rings conforming to IS: 5382 for S&S RCC pipes, with all leads and lifts as directed and giving necessary hydraulic test as per ISS to the required pressure and commissioning etc. complete. (Contractor will make his own arrangements for procuring water for testing). Before the execution of the work, the contractor shall carry out the survey. RCC NP3 Class pipe of 1000 mm dia. | m | 6020.3 | 6020.3 | 4.66 | False | None | None | False | None | False | 28054.598 | 0 | 2645718 | 82436 | None | code68 | Supplying S&S RCC SPUN / VIBRATED CAST PIPES (REINFORCED) pipes NP-3 Class conforming to IS:458-1988 with latest amentments using ordinary portland cement, for sanitary works and conveying to work site, rolling and lowering into trenches, laying true to line and level including loading and unloading at both destinations and jointing of pipes and specials, perfect linking of joints with jack to correct position including cost of jointing materials, i.e, rubber rings conforming to IS: 5382 for S&S RCC pipes, with all leads and lifts as directed and giving necessary hydraulic test as per ISS to the required pressure and commissioning etc. complete. (Contractor will make his own arrangements for procuring water for testing). Before the execution of the work, the contractor shall carry out the survey. RCC NP3 Class pipe of 1200 mm dia. | m | 10279.5 | 10279.5 | 5.36 | False | None | None | False | None | False | 55098.12 | 0 | 2645719 | 82436 | None | code69 | INDIAN FLAG POST: Fabrication, Supplying, Erection, Testing and Commissioning of ...... ms long Polygon high mast with Single/Multiple telescopic sections having, (minimum overlap distance of 1.5 times of top section) thickness as per BSEN 10025 grades 355 JO/ASTM A572-50 steel sheet plate for shaft suitable to withstand a wind velocity of 47 m/s as per IS 875 part 3(as per GA Drawing). Base plate as per IS 2062/ASTM A572-50. The mast shall be Galvanized in single Hot-dip as per BSEN ISO 1461/ASTM A123 with an average 70 microns as per IS 2629, and welded as per BS 5135 Single L-Seam joint The mast shall have 2 Way head frame with die cast LM-6 pulleys, stainless steel axle, Phosphorus Bronze bearing bush press-fitted with separate guides for 2 runs of 5 mm dia, stainless steel wire rope of AISI 304grade 7/19-core, (Factor of Safety as per TR no-7). 2.5 mm2 EPR insulated PCP sheathed trailing power cable housed inside the bottom shaft of mast with door having locking arrangement The mast shall have manual/power tool (Suitable reversible geared motor operating on 230/415V, 50Hz, shall be provide above 15 Mtr mast) The mast shall have lantern of 2 segments, suitable dia with max load carrying capacity as per IS 1239. The mast shall be erected on existing RCC footing. The mast shall be supplied with 3 mm thick template, lightning arrester of 1.2m length galvanized pipe with top arrow fitted on top of the head frame cover and GLS type aviation twin l A fitting with wiring complete. (excluding foundation) as per technical data. 16 m - Top 150 mm and Bottom 410 mm dia | Each | 195000.0 | 195000.0 | 1.0 | False | None | None | False | None | False | 195000.0 | 0 | 2645720 | 82436 | None | code70 | Fabricating, providing and erecting in position of MS Hot Dip Galvanised Sq. Hallow Poles of 132 X 132 Heavy gauge of length 3000mm with MS. Hot dip Galvanised grill work as per approved design and drawing of chief architect. Using 12 X 75mm galvanised flat for alround frame and 20 X 20mm galvanised forged design with square for vertical at 150mm c/c as shown in the drawing including providing forged ornamental arrowhead at top and bottom. The work is inclusive of throughing flat, square rods, placing welding all the joints, including grinding, finishing 2 coats of anticorrosive paint over one coat of metal primer. The rate is inclusive of all materials like MS. Hollow galvanized pipe, flats, forged square rods, cost of labour for all items of work cost painting, welding, cutting, grinding with all lead and lift as per specification including loading and unloading with cost and conveyance of all materials, labour, machinery andincidental charges for the successful completion of the work as per the direction of the Engineer-in-charge of the work. | Sqm | 15630.0 | 15630.0 | 120.0 | False | None | None | False | None | False | 1875600.0 | 0 | 2645721 | 82436 | None | code71 | DRY DECK - SUPPLY & INSTALLATION INCLUDING CONTROL SYSTEM,20' x 20' dry deck featuring Filteration works with filter, pump, inlet points, plumbing, control valve, electrical works, electromechanical nozzles foam jet nozzles nos, universal ball joint nos, 1" ball valve nos, submersible pump 5hp, 3phase, pump & panel, starter panel, nozzle mounted IP68 LED lights 9W SS 304 RGBW, SS 304 grating 400 x 400 mm with orifice for nozzle & light - fabricated as per the dry deck design. Power driver for under water lights 12V 4A 8 nos, junction box 4 nos. PVC pipes of PN6 & PN10 pipes. The fittings will be PN4 & PN6 as per ISI stanadards. Fittings 90 mm, 50mm, 32mm PVC pipe PN10 with necessary fittings of PN6, 90mm Butterlfy valve with flanges. Design, shop drawing, transportation & installtions , testing & commissioning, cost including all materials, labour , lead and lift, transportation inclusive of installation and any other charges and as per directions of the engineer incharge of the works | Nos. | 594000.0 | 594000.0 | 10.0 | False | None | None | False | None | False | 5940000.0 | 0 |
|