createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1708089007765
version5
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd547500.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose26-02-2024 17:00:00
tenderQueryClose21-02-2024 17:00:00
technicalBidOpen28-02-2024 11:00:00
publishedDate16-02-2024 19:40:21
publishedByPostKKRTC_EE_HOFF_KLB
publishedByUserKPE11172 - CHANNAN BORAIAH
bidValidityPeriod90
noOfCalls1
preBidMeetingDate23-02-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonChannana Boraiah
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber8472220663
mobileNumber7760992033
tenderSupplierListNone
tenderSchedule
createdTs1708089007789
version6
createdDateNone
modifiedDateNone
tenderNumberKKRTC/2023-24/BD/WORK_INDENT20
titleConstruction of New Ultra Modern Bus Station at Mahagaon Dist Kalaburagi.
descriptionConstruction of New Ultra Modern Bus Station at Mahagaon Dist Kalaburagi.
categoryWORKS
categoryTextWorks
ecv30138213.07
deptNameKalyana Karnataka Road Transport Corporation
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location5935
locationNameKalyana Karnataka Road Transport Corporation Head Office Kalburgi
provisionalAmount36500000.0
groupOverheadTotal0.0
fileNumberKKRTC/EEG/KLB/DB/T/927/2023-24
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17080890080000NoneNoneBuildingsConstruction of New Ultra Modern Bus Station at Mahagaon Dist Kalaburagi.30138213.07
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
265905782774Nonecode01Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as perdrawing and technical specifications, including setting out, shoring, strutting, barricading,caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.SRP- Vol-I (8/1.14.1) Depth exceeding 1.5 m, but not exceeding 3 m.In all kinds of soils Depth upto 3 mCum107.1107.11167.08FalseNoneNoneFalseNoneFalse124994.2680
265905882774Nonecode02Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.SRP- Vol-I (8/1.15.1) 1 In ordinary/soft rock without blasting upto 1.5 m depthCum381.15381.15219.1FalseNoneNoneFalseNoneFalse83509.9650
265905982774Nonecode03Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. SRP- Vol-I (7/1.8)Cum497.7497.71237.5FalseNoneNoneFalseNoneFalse615903.750
265906082774Nonecode04Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. SRP- Vol-III (24/4.27)Cum2686.952686.95165.0FalseNoneNoneFalseNoneFalse443346.750
265906182774Nonecode05Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS. 383, the size of coarse aggregate not exceeding 25 mm,aggregate cement ratio not to exceed 15.1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing.SRP- Vol-III (43/6.1)complete in C.C. 1.6.12 prop )Cum5166.05166.0206.25FalseNoneNoneFalseNoneFalse1065487.50
265906282774Nonecode06Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing,and all the other appurtenances requiredcomplete the work as pertechnical specifications. (The cost of steel reinforcement & formwork shall be paid separately).SRP- Vol-I (15/2.1.2) Mix 1.4.8( M7.5) Using 40 mm nominal size graded crushed coarse aggregatesCum5947.25947.2175.15FalseNoneNoneFalseNoneFalse1041652.080
265906382774Nonecode07Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.SRP- Vol-I (7/1.9)Cum279.3279.3529.89FalseNoneNoneFalseNoneFalse147998.2770
265906482774Nonecode08KSRB 2.3 . Filling (new earth )Refilling available earth around trenches/pipelines, cables in layersnot exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m .Including cost of all labour complete as per specifications.SRP- Vol-I (7/1.11)Cum441.0441.0785.49FalseNoneNoneFalseNoneFalse346401.090
265906582774Nonecode09Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators,providing weep holes wherever necesary, including all lead & lifts, costof all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately).SRP- Vol-I (17/2.4.1) Mix 1.2.4 (M15) Using 20 mm nominal size graded crushed coarse aggregatesCum6724.26724.29.35FalseNoneNoneFalseNoneFalse62871.270
265906682774Nonecode10Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately).SRP- Vol-I (15/2.2.3) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SRP 115/1 (Foundation upto plinth (a) Isolated)Cum7185.027185.02134.66FalseNoneNoneFalseNoneFalse967534.79320
265906782774Nonecode11Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately).SRP- Vol-I (15/2.2.1) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SRP 115/1 (Foundation upto plinth (a) Isolated)Cum7129.467129.4644.9FalseNoneNoneFalseNoneFalse320112.7540
265906882774Nonecode12Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (17/2.5.2) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SRP 115/8 (Column & Piers as per corrigendum-3)Cum12214.7612214.7671.35FalseNoneNoneFalseNoneFalse871523.1260
265906982774Nonecode13Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (17/2.5.1) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SRP 115/8 (Column & Piers as per 3rd Corrigendum-3)Cum11834.5511834.5511.21FalseNoneNoneFalseNoneFalse132665.30550
265907082774Nonecode14Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (17/2.5.2) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SRP 115/8 (Plinth beams of Building as per corrigendum-3)Cum10777.7310777.7331.07FalseNoneNoneFalseNoneFalse334864.07110
265907182774Nonecode15Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (17/2.5.2) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SRP 115/12 (Beam and Lintel of Building as per corrigendum-3)Cum11496.2411496.2465.85FalseNoneNoneFalseNoneFalse757027.4040
265907282774Nonecode16Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (17/2.5.1) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11138.411138.433.88FalseNoneNoneFalseNoneFalse377368.9920
265907382774Nonecode17Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (17/2.5.2) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SRP 116/13 (Roof (Straight & Arched as per corrigendum 3)Cum10777.7310777.73198.94FalseNoneNoneFalseNoneFalse2144121.60620
265907482774Nonecode18Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (17/2.5.1) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SRP 116/13 (Roof (Straight & Arched as per 3rd Corrigendum)Cum10442.2510442.255.4FalseNoneNoneFalseNoneFalse56388.150
265907582774Nonecode19Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (17/2.5.2) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SRP 116/20 (Chejjas,canopy & other Arch Projection of minor section)Cum10418.4710418.470.69FalseNoneNoneFalseNoneFalse7188.74430
265907682774Nonecode20Construction of M40 grade un-reinforced,Cement Concrete Pavement with OPC/PPC/PSC dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383.2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing SRP- Vol-III (43/6.2)Cum9514.059514.05330.0FalseNoneNoneFalseNoneFalse3139636.50
265907782774Nonecode21Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot ressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991.from manufacturer complete as per spcification.SRP- Vol-II (106/12.57.4) 35 mm thick Both side teakSqm4758.64758.617.01FalseNoneNoneFalseNoneFalse80943.7860
265907882774Nonecode22Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.SRP- Vol-II (100/12.12)Cum130412.1130412.10.47FalseNoneNoneFalseNoneFalse61293.6870
265907982774Nonecode23Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. SRP- Vol-II (105/12.54)Rmtr333.9333.945.6FalseNoneNoneFalseNoneFalse15225.840
265908082774Nonecode24VOL II SRP 106/12.55.1 Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges (both side prelam)Sqm2484.32484.312.6FalseNoneNoneFalseNoneFalse31302.180
265908182774Nonecode25Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.SRP- Vol-II (85/11.34A)Kg176.4176.41454.04FalseNoneNoneFalseNoneFalse256492.6560
265908282774Nonecode26Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1.6 (1 cement . 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.SRP- Vol-II (14/6.8)Cum8367.458367.45160.15FalseNoneNoneFalseNoneFalse1340047.11750
265908382774Nonecode27Providing 15 mm cement plaster on the rough side of single or half brick wall of mix .1.4 (1 cement. 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SRP- Vol-II (41/8.2.1)Sqm309.75309.751356.5FalseNoneNoneFalseNoneFalse420175.8750
265908482774Nonecode28Providing 15 mm cement plaster on the rough side of single or half brick wall of mix .1.6 (1 cement. 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SRP- Vol-II (41/8.2.2)Sqm292.95292.95576.0FalseNoneNoneFalseNoneFalse168739.20
265908582774Nonecode29Providing 12 mm cement plaster with cement mortar 1.4 (1 cement.4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SRP- Vol-II (41/8.1.1)Sqm267.75267.75332.96FalseNoneNoneFalseNoneFalse89150.040
265908682774Nonecode30Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS. 733 and IS.1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) .For Fixed Portion. Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications.SRP-Vol-II (11.35.1.2/86)Kg513.45513.4590.58FalseNoneNoneFalseNoneFalse46508.3010
265908782774Nonecode31Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item).With float glass panes of 5 mm thickness (weight not less than 12.50 kg/m²) including cost of materials, labour, usage charges of machinery complete as per specifications.SRP-Vol-II (11.37.2/82)Sqm1229.551229.5515.86FalseNoneNoneFalseNoneFalse19500.6630
265908882774Nonecode32Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing,polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners,stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.SRP- Vol-II (83/11.28)Kg593.25593.2535.64FalseNoneNoneFalseNoneFalse21143.430
265908982774Nonecode33Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1.6, 20 mm thick, and joints finished with cement mortar 1.3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. SRP- Vol-II (64/9.30)Sqm5594.45594.4250.73FalseNoneNoneFalseNoneFalse1402683.9120
265909082774Nonecode34Providing and laying Polished Glazed Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08percentage and conforming to IS.15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming (Payment for grouting of joints to be made separately). SRP- Vol-II (62/9.22.2)Size of Tile 600x600 mmSqm1392.31392.3109.73FalseNoneNoneFalseNoneFalse152777.0790
265909182774Nonecode35Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1.6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab,including cost of materials,labour,curing, polishing complete as per specifications.SRP- Vol-II (64/9.34)Sqm1622.251622.25108.57FalseNoneNoneFalseNoneFalse176127.68250
265909282774Nonecode36Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc.complete as per design approved by Engineer-in-charge. SRP- Vol-II (69/10.2)Rmtr344.4344.4100.0FalseNoneNoneFalseNoneFalse34440.00
265909382774Nonecode37Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening,cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) SRP- Vol-I (18/2.11/a)Kg93.9293.9258528.89FalseNoneNoneFalseNoneFalse5497033.34880
265909482774Nonecode38Supplying, fitting and placing un-coated Mild steel reinforcement complete in foundation as per drawing and technical specification. SRP- Vol-I (18/2.12)Kg77.477.412375.0FalseNoneNoneFalseNoneFalse957825.00
265909582774Nonecode39Providing and fixing Structural Steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.SRP- Vol-II (75/11.1)Kg111.3111.35943.13FalseNoneNoneFalseNoneFalse661470.3690
265909682774Nonecode40Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 percentage) total coated thickness with zinc coating 120 grams per m2 as per IS. 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces,excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. SRP- Vol-II (26/7.38)Sqm596.4596.4338.91FalseNoneNoneFalseNoneFalse202125.9240
265909782774Nonecode41Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories,sealing shall be done with necessary rods etc., complete SRP- Vol-II (71/10.15.1)Sqm4188.454188.4529.82FalseNoneNoneFalseNoneFalse124899.5790
265909882774Nonecode42Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/ eams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval fromstructural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts,washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glasspanel inside the SS channel shall be measured.SRP- Vol-II (160/18.7)Sqm8349.68349.612.78FalseNoneNoneFalseNoneFalse106707.8880
265909982774Nonecode43KSRB 7.15 .Providing , fabricating, assembling and fixing in position anodized aluminum partions using aluminium section of mat finish or glassy finish in combination of plain grove, single groove, single grove and double grove as per requirements for the frames of overall size 63.5mmx38.1mm. with thickness of 2 mm having section weight, plain sections. 1.054 kg/m, single grove thickness 1.95mm section weight. 1.094kg/m and bottom member 114.3mm x 44.45mm thickness 3.18mm weight 2.646 kg/m aluminium louvers section of size 36.5mmx34.93mm 1.45mm thick section weight 0.429kg/m bottom prortion provided with 12mm thick prelaminated sheet both sides of approved portion viz., 0.9m to 2.13m and top panel with louvers sections; the glass and panels fitted wtih glazing clips of 19mm x 17.3mm of thickness 0.9mm weight 0.13 and top panel with louvers sections; the glass and panels fitted with glazing clips of 19mmx 17.3mm of thickness 0.9mm weight 0.124kg/m aluminium setions anodised 12 to 15 microns, sections treated for removal of any rust and prevention of further rust formation, coated with greasy materials for non adherence of mortars or any other sticky materials ; vertical members embedded in the flooring by making suitable sized holes and fixing with cement mortar, with necesary opening for fixing of door of standard size ( excluding cost of door ) all the frame throughly cleaned, free from rust , scale of dirt including cost of materials, fixtures, labour and HOM of machinery complete as per specification SRP 38/7.15.2 ( Powder Coated )Sqm3432.03432.04.86FalseNoneNoneFalseNoneFalse16679.520
265910082774Nonecode44Constructing brick maconary inspection chamber of internal dimention 600 X 450 mm, and depth of 600mm ( Inner dimension ) with modular bricks of class designation 75 in Cm 1.6 bed concrete 150mm thick with 1.3.6 with plastering 12 mm thick with CM 1.4.CC 1.2.4 cooping 75mm thick for fixing CI cover & frame etc.(excluding cost of CI frame & cover). SRP- Vol-V 16.9/191Each5030.555030.553.0FalseNoneNoneFalseNoneFalse15091.650
265910182774Nonecode45Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will makehis own arrangements for procuring water for testing) etc.Note. Upto 110mm dia Coil shall be used. SRP- Vol-V 94/9.1.4Rmtr492.45492.45290.0FalseNoneNoneFalseNoneFalse142810.50
265910282774Nonecode46Supplying PVC ringtite pipes conforming to IS 4985.2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes andspecials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for. PVC pipes 110mm dia., 6 kg/sqcm & class 3 SRP- Vol-V 113/10.1.7)Rmtr431.55431.55100.0FalseNoneNoneFalseNoneFalse43155.00
265910382774Nonecode47Supplying, lowering, laying, jointing, testing and commissioning of Glazed Stone Ware Pipes of following dia, conforming to IS 651.1992,IS 4127 with latest amendments, including conveying to work site,caulking with hemp dipped in tar and jointing with CM 1.1.5 using OPC, perfect linking and curing for 10 days and testing with water etc. with all lead, lifts and as per Technical Specifications. The cost to include the cost of all jointing materials, necessary survey works for laying of sewer lines etc. complete. The contractor will make own arrangements for procuring water for testing.150 mm dia. pipes SRP- Vol-V 187/16.1.2Rmtr610.05610.0570.0FalseNoneNoneFalseNoneFalse42703.50
265910482774Nonecode48Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.SRP- Vol-II (50/8.51)Sqm105.0105.01260.98FalseNoneNoneFalseNoneFalse132402.90
265910582774Nonecode49Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade .New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. SRP- Vol-II (45/8.25)Sqm143.85143.851260.98FalseNoneNoneFalseNoneFalse181391.9730
265910682774Nonecode50Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC.Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400Percentage and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification.Sqm857.85857.85100.0FalseNoneNoneFalseNoneFalse85785.00
265910782774Nonecode51Finishing walls with water proofing cement paint of required shade .New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.. (Apex Paint) SRP- Vol-II (45/8.28)Sqm93.4593.45908.96FalseNoneNoneFalseNoneFalse84942.3120
265910882774Nonecode52Providing and placing on terrace ( at all floor levels ) polyethylene water storage tanks,IS . 12701 marked,with cover and suitable locking arrangement and making necessary holes for for inlet,oulet and overflow pipes but without fittings and the base support for tank. SRP- Vol-II (12/13.34)Ltr9.459.454000.0FalseNoneNoneFalseNoneFalse37800.00
265910982774Nonecode53Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes having thermal stability for hot and cold water supply incl all CPVC plain & brass threaded fittings. This incl jointing of pipes and fittings with one step CPVC solvent cement,trenching,refilling and testing of joints complete 50mm dia as pe direction of Engineer in charge External work SRP- Vol-II (11/13.33.6) 40 mmMtr500.85500.85100.0FalseNoneNoneFalseNoneFalse50085.00
265911082774Nonecode5425 mmMtr310.8310.890.0FalseNoneNoneFalseNoneFalse27972.00
265911182774Nonecode5520 mmMtr227.85227.8510.0FalseNoneNoneFalseNoneFalse2278.50
265911282774Nonecode5615 mmMtr174.3174.325.0FalseNoneNoneFalseNoneFalse4357.50
265911382774Nonecode57White Vitreous China Flat back wash basin size 450x 300 mm with single 15mm C.P. brass pillar tap SRP- Vol-II (133/14.7.7)Nos2655.452655.453.0FalseNoneNoneFalseNoneFalse7966.350
265911482774Nonecode58White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. SRP- Vol-II (126/14.13.2)Nos2447.552447.556.0FalseNoneNoneFalseNoneFalse14685.30
265911582774Nonecode59Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete,including painting of fittings and brackets, cutting and making good the walls and floors wherever required. W.C. pan with ISI marked black solid plastic seat and lid. SRP- Vol-II (123/14.3.2)Nos6095.256095.252.0FalseNoneNoneFalseNoneFalse12190.50
265911682774Nonecode60Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS . 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required .VOL II 124/14.5.1Each9074.19074.16.0FalseNoneNoneFalseNoneFalse54444.60
265911782774Nonecode61Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing . SRP- Vol-II (128/14.32.3)Unit1119.31119.32.0FalseNoneNoneFalseNoneFalse2238.60
265911882774Nonecode62Providing and fixing C I Nahani trap of approved make confirming to ISI specifications and construction of cistern in CC 1.2.4 as per directions (Inclusive of cost of materials and fixtures) 12.5 cms x 7.5 cms SRP 90 / 12.113.2Each285.0285.02.0FalseNoneNoneFalseNoneFalse570.00
265911982774Nonecode63Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete. 15 mm nominal bore SRP- Vol-II (117/13.5.1)Nos310.8310.85.0FalseNoneNoneFalseNoneFalse1554.00
265912082774Nonecode64Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) 40 mm nominal bore SRP- Vol-II (117/13.4.3)Nos737.1737.12.0FalseNoneNoneFalseNoneFalse1474.20
265912182774Nonecode65Providing and fixing brass stop cock of approved quality 15 mm nominal bore SRP- Vol-II (115/13.3.1)Nos342.3342.38.0FalseNoneNoneFalseNoneFalse2738.40
265912282774Nonecode66Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation com plete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS. 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x0.90 mm M.S. laths with 0.90 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.SRP- Vol-II (76/11.6.3)Sqm2388.752388.75100.25FalseNoneNoneFalseNoneFalse239472.18750
265912382774Nonecode67Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS . 15622, of approved make, in all colours, shades, except White,Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1.4 (1 Cement . 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. SRP- Vol-II (60/9.11)Sqm933.45933.458.66FalseNoneNoneFalseNoneFalse8083.6770
265912482774Nonecode68Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1.3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. SRP- Vol-II (65/9.38)Sqm1461.61461.675.12FalseNoneNoneFalseNoneFalse109795.3920
265912582774Nonecode69Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1.3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, griding the edge to half/full round wherever required, labour, curing complete as per specification.SRP- Vol-II (65/9.40)Sqm978.6978.659.91FalseNoneNoneFalseNoneFalse58627.9260
265912682774Nonecode70Supplying and fixing MS Chairs & 3 seater of approved qulaity including fixing in flooring drilling to the suitable holes grouting complete as per direction of Engineer in charge of work complete as per specifications with all lead and lift. (Approved rate)Nos5500.05500.040.0FalseNoneNoneFalseNoneFalse220000.00
265912782774Nonecode71Hydraulic Excavator of 0.9 m3 bucket (J.C.B excavator) Levelling the ground SRP- Vol-I (A-45/50)Hour1417.51417.512.0FalseNoneNoneFalseNoneFalse17010.00
265912882774Nonecode72Korean truff (Bijapur BS Approved Rate)Sqm175.0175.050.0FalseNoneNoneFalseNoneFalse8750.00
265912982774Nonecode73Providing & supplying of plants from forest department of plants size 14inch x 20inch with supporting guard stick including transportation loading unloading placeing the plants in pits of 1 Mtr x 1 Mtr x 1 Mtr of size pits and refiling of required quantity and watering etc., complete.Each100.0100.050.0FalseNoneNoneFalseNoneFalse5000.00
265913082774Nonecode74Providing patti allround compound wall etc, with CM 1.3 and finished as per design and specification including scafolding etc, complete. Patti 10cm wide and 10 mm thick.Rmtr11.8811.88421.2FalseNoneNoneFalseNoneFalse5003.8560
265913182774Nonecode75Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth,including over burden upto 20M, fixing ofcasing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes,collars and caps etc.) for SRP- Vol-V 139/12.2 Borewell depth of 0 to 50 mRmtr324.45324.4560.0FalseNoneNoneFalseNoneFalse19467.00
265913282774Nonecode76Borewell depth of 50 to 100 mRmtr406.35406.3530.0FalseNoneNoneFalseNoneFalse12190.50
265913382774Nonecode77Borewell depth of 100 to 150 mRmtr432.6432.660.0FalseNoneNoneFalseNoneFalse25956.00
265913482774Nonecode78Supplying PVC ringtite pipes conforming to IS 4985.2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes andspecials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for. PVC pipes 160mm dia., 6 kg/sqcm & class 3 SRP- Vol-V 134/1.9)Rmtr628.95628.9520.0FalseNoneNoneFalseNoneFalse12579.00
265913582774Nonecode79Supplying PVC ringtite pipes conforming to IS 4985.2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes andspecials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for. PVC pipes 140mm dia., 6 kg/sqcm & class 3 SRP- Vol-V 113/10.1.8)Rmtr613.2613.240.0FalseNoneNoneFalseNoneFalse24528.00
265913682774Nonecode80Geophysical investigation at site for sinking borewells for supplying drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers’s method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE. 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15percentage, b) Above 30 M - 30percentage (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. 5 O050A Cleaning of borewells including yield.VOL-V 139/12.2Each5288.05288.01.0FalseNoneNoneFalseNoneFalse5288.00
265913782774Nonecode81Stone Work ( Machine cut edges ) for wall lining etc,( Veneer work) upto 10 mtr height backing filled with a grout of average 12mm thick cement motar 1.3 ( 1 cement . 3 coarse sand) including pointing in white cement mortar 1.2 ( 1 white cement . 2 stone dust) with an admixture of pigment matching the stone shade ( to be secured to the backing and the sides by means of cramps and pins which shall be paid for seperately) white sand stone exposed face fine dressed with rough 30mm thick ( SRP 121/7.23.3.5 )(CSR) ( approved in Developmental works in Sedam Bus Station )Sqm2962.052962.0535.0FalseNoneNoneFalseNoneFalse103671.750
265913882774Nonecode82Providing and laying a burried expansion joint, expansion gap being 20 mm, covered with 12 mm thick, 200 mm wide galvanised weldable structural steel plate as per IS. 2062, placed symmetrical to centre line of the JOint, resting freely over the top surface of the deck concrete, welding of 8 mm dia. 100 mm long galvanised nails spaced 300 mm c/c along the centre line of the plate, including cost of materials, labour, HOM complete as per specifications, all as specified in clause 2600.4 MORTH Specification No. 2604 SRP 31.1( 18-19 SR)Mtr1253.71253.7120.0FalseNoneNoneFalseNoneFalse150444.00
265913982774Nonecode83Providing 12 mm cement plaster finished with a floating coat of neat cement of mix .1.4 (1 cement. 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge..SRP- Vol-II(41/8.4.2))Sqm327.6327.6170.0FalseNoneNoneFalseNoneFalse55692.00
265914082774Nonecode84Providing and laying red oxide flooring 40 mm thick, with an under layer of 30mm thick M-15 cement concrete and top layer of 10mm thick plaster with 1.3 cement mortar mixed with red oxide finished with floating coat of neat cement mixed with red oxide ( mix of same proportion ) , including cost of materials, labour, curing, complete as per specifications..SRP- Vol-II(67/9.37)Sqm825.3825.3110.0FalseNoneNoneFalseNoneFalse90783.00
265914182774Nonecode85Storage Unit- Wooden -One side laminate Providing and fixing woode storage unit one side laminate with 18 mm PLY/PLPB with edge bound for body, 18mm PLY/PLPB with openable shutters and individual locking system for shutter, 9 mm PLY with edge bound for rear portion with Hafele fitting hinges, Hafele locks, Minifix assembly, screw legs, Handles and tower bolt complete as per specifications, drawings and as directed by Engineer in charge.PLY STORAGE - 900 mm W X 430 mm D X 2100 mm Ht SRP( SR 18-19) (39.24.3)Sqm20790.020790.02.0FalseNoneNoneFalseNoneFalse41580.00
265914282774Nonecode86Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required .SRP- Vol-I (134/14.11.2) Size 600x450x200 mmNos5336.15336.12.0FalseNoneNoneFalseNoneFalse10672.20
265914382774NoneElecl code87SRP 1.2 Concealed Conduit SystemSupplying heavy gauge PVC conduit pipe 25 mm dia 2 .mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary25mm dia 2mm thick 1.2.2Rmtr81.981.9800.0FalseNoneNoneFalseNoneFalse65520.00
265914482774NoneElecl code88SRP. 1.3.2 -Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25mm dia 2mm thickRmtr82.9582.95500.0FalseNoneNoneFalseNoneFalse41475.00
265914582774NoneElecl code891.1.2 Open Conduit System.Supplying heavy gauge PVC conduit pipe …….dia .......mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structureor rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.25mm dia 2mm thickRmtr85.0585.0590.0FalseNoneNoneFalseNoneFalse7654.50
265914682774NoneElecl code90SRP 2.3 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694.confirming to latest amendments. 1.5 sqmm 2.3.2Rmtr27.327.31700.0FalseNoneNoneFalseNoneFalse46410.00
265914782774NoneElecl code91Do- 2.5 sqmm (P6/2.3.3)Rmtr44.144.11500.0FalseNoneNoneFalseNoneFalse66150.00
265914882774NoneElecl code92Do- 4sqmm (P6/2.3.4)Rmtr66.1566.15499.0FalseNoneNoneFalseNoneFalse33008.850
265914982774NoneElecl code93Do- 6sqmm (P6/2.3.5)Rmtr96.696.6150.0FalseNoneNoneFalseNoneFalse14490.00
265915082774NoneElecl code94Do- 10sqmm (P6/2.3.6)Rmtr175.35175.3570.0FalseNoneNoneFalseNoneFalse12274.50
265915182774NoneElecl code95Do- 16sqmm(P6/2.3.7)Rmtr333.9333.950.0FalseNoneNoneFalseNoneFalse16695.00
265915282774NoneElecl code96SRP.2.2.1.Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694. and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point upto 3Mtr from tapping point to out let via switch boxNo282.45282.4532.0FalseNoneNoneFalseNoneFalse9038.40
265915382774NoneElecl code97Do- Medium point above 3 Mtr upto 6Mtr from tapping point to outlet via switch box. (P5/2.2.2)No397.95397.9530.0FalseNoneNoneFalseNoneFalse11938.50
265915482774NoneElecl code98Do- Long point above 6 Mtr upto 10Mtr from tapping point to outlet via switch box. (P5/2.2.3)No582.75582.7535.0FalseNoneNoneFalseNoneFalse20396.250
265915582774NoneElecl code99Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall.1-3Way 3.4.1No144.9144.925.0FalseNoneNoneFalseNoneFalse3622.50
265915682774NoneElecl code100Do- 4-5way (P15/3.4.3)No185.85185.8530.0FalseNoneNoneFalseNoneFalse5575.50
265915782774NoneElecl code101Do-6 way (P15/3.4.4)No231.0231.040.0FalseNoneNoneFalseNoneFalse9240.00
265915882774NoneElecl code102Do-10-12 way (P15/3.4.6)No334.95334.9550.0FalseNoneNoneFalseNoneFalse16747.50
265915982774NoneElecl code103Do-18 way (P15/3.4.8)No425.25425.256.0FalseNoneNoneFalseNoneFalse2551.50
265916082774NoneElecl code104Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc complete on the existing metal/PVC box.1 to 3 Module 3.5.1No143.85143.8550.0FalseNoneNoneFalseNoneFalse7192.50
265916182774NoneElecl code105Do- 4 module (P16/3.5.3)No183.75183.7540.0FalseNoneNoneFalseNoneFalse7350.00
265916282774NoneElecl code106Do- 6 Module (P16/3.5.4)No245.7245.740.0FalseNoneNoneFalseNoneFalse9828.00
265916382774NoneElecl code107Do-10-12 Module (P16/3.5.6)No361.2361.250.0FalseNoneNoneFalseNoneFalse18060.00
265916482774NoneElecl code108Do-18 Module (P16/3.5.8)No479.85479.8510.0FalseNoneNoneFalseNoneFalse4798.50
265916582774NoneElecl code109Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch 3.6.1No107.1107.1210.0FalseNoneNoneFalseNoneFalse22491.00
265916682774NoneElecl code110Do- 6Amps 3 way socket (P16/3.6.3)No179.55179.5542.0FalseNoneNoneFalseNoneFalse7541.10
265916782774NoneElecl code111Do- modular stepped fan regulator (P16/3.6.4)No374.85374.8520.0FalseNoneNoneFalseNoneFalse7497.00
265916882774NoneElecl code112Do- 16Amps one way switch (P16/3.6.7)No189.0189.015.0FalseNoneNoneFalseNoneFalse2835.00
265916982774NoneElecl code113Do- 6/16 Amps universal socket (P16/3.6.10)No247.8247.816.0FalseNoneNoneFalseNoneFalse3964.80
265917082774NoneElecl code114Supplying and fixing Fan box with round hook (P3/1.13)No122.85122.8524.0FalseNoneNoneFalseNoneFalse2948.40
265917182774NoneElecl code115Supplying PVC/GI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely 25mm 1.9.2Mtr23.123.170.0FalseNoneNoneFalseNoneFalse1617.00
265917282774NoneElecl code116Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70Percentage lumen maintenance with CRI morethan 80. Power Input. 220-240V @ 50/60Hz & Power factor morethan0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.11.3.2 LED light fighting 1 x4feet- 20/22 wNo724.5724.550.0FalseNoneNoneFalseNoneFalse36225.00
265917382774NoneElecl code11711.5.3. Supply of round/square recess/surface mounted rolling type LED Down light with .......W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70Percentage lumen maintenance with CRI morethan 80. Power Input. 220-240V @ 50/60Hz & Power factor morethan0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18WNo1390.21390.28.0FalseNoneNoneFalseNoneFalse11121.60
265917482774NoneElecl code118Supplying of recess mounting non integral type ........LED ...... W luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded fase ceiling clamps, Power LEDs with CCT 6500 degree K, CRImorethan 70Percentage. Efficacy morethan100 lumen per watt, 120degree beam spread, lifemorethan 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF morethan 0.95, power loss should Less than 5Percentage of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, , THD less than 20Percentage, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2feetx2feet / 1feet x 4feet 34 -36watt 12.6.2No4780.654780.6512.0FalseNoneNoneFalseNoneFalse57367.80
265917582774NoneElecl code11911.8.4 Supply of LED Streetlight luminaire 90 watt with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70Percentage, maximum light intensity should be between 60 degrees to 70 degrees. CCT morethan 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire morethan IK08. Power Factor morethan0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiencymorethan130lm/w, nominal CRI morethan75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001.2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/Lumileds/Osram make LED Source.LED Streetlight 90 WattsNo9303.09303.012.0FalseNoneNoneFalseNoneFalse111636.00
265917682774NoneElecl code1206.3.1..Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system.No3133.23133.26.0FalseNoneNoneFalseNoneFalse18799.20
265917782774NoneElecl code1216.2.1.Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete.12inch Sweep (300mm) 7.2.1No3117.453117.454.0FalseNoneNoneFalseNoneFalse12469.80
265917882774NoneElecl code122Fixing all types and all capacities of fluorescent / false ceiling/ spot light / CFL / LED fittings indoor on the wall / ceiling /rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.On wall / ceiling / Rafter / Girders 13.7.1No128.1128.150.0FalseNoneNoneFalseNoneFalse6405.00
265917982774NoneElecl code123Supplying and Fixing........mm dia class A GI pipe bracket up to 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clamps, bolts, nuts and wiring using suitable capacity wires.Using 40mm dia G.I.Pipe 13.2.3No1551.91551.910.0FalseNoneNoneFalseNoneFalse15519.00
265918082774NoneElecl code124Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing feetSfeet hook with fan regulator to the existing board together with supplying and fixing 5 amps. Ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.13.10No179.55179.556.0FalseNoneNoneFalseNoneFalse1077.30
265918182774NoneElecl code125Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.13.13No742.35742.354.0FalseNoneNoneFalseNoneFalse2969.40
265918282774NoneElecl code126Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and feetCfeet Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.5.18.1 6-32Amps SPNo435.75435.7550.0FalseNoneNoneFalseNoneFalse21787.50
265918382774NoneElecl code127Do- 6-32 Amps DP. (5.18.2)No775.95775.9530.0FalseNoneNoneFalseNoneFalse23278.50
265918482774NoneElecl code128Do- 6-32 Amps TPN. (5.18.7)No1802.851802.858.0FalseNoneNoneFalseNoneFalse14422.80
265918582774NoneElecl code129Do- 50-63Amps TPN . (5.18.9)No3242.43242.42.0FalseNoneNoneFalseNoneFalse6484.80
265918682774NoneElecl code13011.2.1.Supplying & fixing retrofit type -PL- LED Lamp .......W LED linear source with CCT 6500 degree K, CRImorethan 70Percentage. efficacy morethan80 lumen per watt, lifemorethan 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF morethan 0.95, power loss should Less than 5Percentage of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20Percentage, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.Each654.15654.154.0FalseNoneNoneFalseNoneFalse2616.60
265918782774NoneElecl code131Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (Icu = Ics) 5.14.9 160Amps 25kA.No14119.3514119.353.0FalseNoneNoneFalseNoneFalse42358.050
265918882774NoneElecl code1325.30.Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 20A single phase Class-1 Accuracy with Temper Proof Energy Meter.No1449.01449.010.0FalseNoneNoneFalseNoneFalse14490.00
265918982774NoneElecl code133Supplying, fixing and wiring 3 Phase Digital Ammeter /Voltmeter.5.29No1496.251496.251.0FalseNoneNoneFalseNoneFalse1496.250
265919082774NoneElecl code134Supplying, fixing and wiring 50/5Amps to 400/5 Amps 5VA burden current transformer. 0.5 accuracy. (5.34)No590.1590.13.0FalseNoneNoneFalseNoneFalse1770.30
265919182774NoneElecl code135Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v AC 50Hz 12/24v DC (5.38)No540.75540.753.0FalseNoneNoneFalseNoneFalse1622.250
265919282774NoneElecl code136Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.14SWG 5.42.1 (Unit Sqcm)Sqm0.530.53100000.0FalseNoneNoneFalseNoneFalse53000.00
265919382774NoneElecl code137Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.100Amps 4x30x6mm Aluminium Strips 5.40.1Mtr2588.252588.251.0FalseNoneNoneFalseNoneFalse2588.250
265919482774NoneElecl code138Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.40x40x6mm 5.41.1Mtr320.25320.2512.0FalseNoneNoneFalseNoneFalse3843.00
265919582774NoneElecl code13912.56.Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipmentfeets on the meter board using 40 mm dia2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm diaNo3685.53685.515.0FalseNoneNoneFalseNoneFalse55282.50
265919682774NoneElecl code14012.57.Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40 mm dia 2.9 mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400 mm with a cast iron cover. The earth electrode shall have staggered holes of 12 mm dia and the electrode should be covered 150 mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.No4468.84468.84.0FalseNoneNoneFalseNoneFalse17875.20
265919782774NoneElecl code14112.58.2.Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.25x3mm GI strip.Rmtr86.186.130.0FalseNoneNoneFalseNoneFalse2583.00
265919882774NoneElecl code142Gescom sr/11KV materials/134/18.01.LT Distribution Box for 100 kVA DTC with MCCBfeets (Sheet Metal) (Dwg No. BESCOM/GM/QS&S/58 Dtd 24.11.2018)Each23820.323820.31.0FalseNoneNoneFalseNoneFalse23820.30
265919982774NoneElecl code143Gescom sr/11KV materials/207/32.11. 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 50 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm)Km187921.65187921.650.1FalseNoneNoneFalseNoneFalse18792.1650
265920082774NoneElecl code144Gescom sr/11KV Labour/176/21.06. Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 to 95 SqmmKm32695.9532695.950.1FalseNoneNoneFalseNoneFalse3269.5950
265920182774NoneElecl code145Vol I/1.14.1.Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1Cum107.1107.180.0FalseNoneNoneFalseNoneFalse8568.00
265920282774NoneElecl code146Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes.6.17.1No3.153.15180.0FalseNoneNoneFalseNoneFalse567.00
265920382774NoneElecl code147Do- 2.5 sqmm. (6.17.2)No4.24.2220.0FalseNoneNoneFalseNoneFalse924.00
265920482774NoneElecl code148Do- 4.0 sqmm. (6.17.3)No7.357.3560.0FalseNoneNoneFalseNoneFalse441.00
265920582774NoneElecl code149Do- 6 sqmm. (6.17.4)No7.357.3524.0FalseNoneNoneFalseNoneFalse176.40
265920682774NoneElecl code150Do- 10sqmm.(6.17.5)No8.48.424.0FalseNoneNoneFalseNoneFalse201.60
265920782774NoneElecl code151Do- 16 sqmm. (6.17.6)No13.0613.0612.0FalseNoneNoneFalseNoneFalse156.720
265920882774NoneElecl code152Do- 50 sqmm Long Barrel. (6.17.9)No63.063.016.0FalseNoneNoneFalseNoneFalse1008.00
265920982774NoneElecl code153VOL-5/10.1.4.Supplying PVC ringtite pipes conforming to IS 4985.2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for.PVC pipes 63mm dia., 6 kg/sqcm & class 3Mtr169.05169.05100.0FalseNoneNoneFalseNoneFalse16905.00
265921082774NoneElecl code154Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy.5.33Each9780.759780.751.0FalseNoneNoneFalseNoneFalse9780.750
265921182774NoneElecl code155VOl-6/KPTCL/P.No-158.Jelly Spreading (20-25 mm) . Supplying and providing jelly in the station yard of uniform thickness of 100 mm including the cost of materials, labour charges, required tools and plants etc., complete.Work shall be carried out as per the instructions of Engineerin-charge of works as per the standard procedureCum1861.651861.652.0FalseNoneNoneFalseNoneFalse3723.30
265921282774NoneElecl code156Gescom sr/11KV materials/536/66.04.HDPE/PLB Pipe 50/42 mmKm89264.789264.70.14FalseNoneNoneFalseNoneFalse12497.0580
265921382774NoneElecl code157PWD SR/Vol-5/13.11.5.Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 3 HP 3.00 HP - 90 LPM @ 66 m = 6 STG Outlet Dia - 2.00”Each29518.6529518.651.0FalseNoneNoneFalseNoneFalse29518.650
265921482774NoneElecl code158PWD SR/Vol-5/12.28.Labour charges for Erection of new / repaired submersible pump set along with GI pipes (32mm / 50mm), cable (New submersible pump set if required will be supplied by the department free of cost and released pump set should be handed over to department) including transportation (Each length = 6 m)Job196.35196.3515.0FalseNoneNoneFalseNoneFalse2945.250
265921582774NoneElecl code1592.6.2.Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13.8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 V as per IS-694.2010.Rmtr176.4176.4140.0FalseNoneNoneFalseNoneFalse24696.00
265921682774NoneElecl code1605.1.Supplying push button operated direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for 230/440 V 1/3 phase motor upto 5 HP.Each2023.352023.351.0FalseNoneNoneFalseNoneFalse2023.350
265921782774NoneElecl code161Gescom SR/SSM 11KV/88/12.04.Distribution Transformer - 3 Phase, 11kV/433V - Stacked CRGO Core with Oil as per IS-1180 (Part-1). 2014 63 kVA, Aluminum Wdg, Star 2 (5 Star)No191672.25191672.251.0FalseNoneNoneFalseNoneFalse191672.250
265921882774NoneElecl code162Gescom SR/11KV Labour/72/8.01. Erection of 25 to 63 kVA Transformer on Transformer StructureNo1252.651252.651.0FalseNoneNoneFalseNoneFalse1252.650
265921982774NoneElecl code163Gescom SR/SSM 11KV/1/1.01.RCC Pole - 9 Mtr Long, 145 Kg WLNo7429.87429.82.0FalseNoneNoneFalseNoneFalse14859.60
265922082774NoneElecl code164Gescom SR/11KV Labour/30/2.02.Erection of RCC/PSCC Pole of 9 to 10 Mtr long in a pit of 1.8 Mtr depthNo1168.651168.652.0FalseNoneNoneFalseNoneFalse2337.30
265922182774NoneElecl code165Gescom SR/SSM 11KV/11/2.01.11 kV, Horizontal Cross Arm - Mild Steel (MS)(Dwg No. BESCOM/GM/QS&S/04 Dtd 24.11.2018)No390.6390.64.0FalseNoneNoneFalseNoneFalse1562.40
265922282774NoneElecl code166Gescom SR/11KV Labour/51/5.03.Fixing of V-Shape/Horizontal cross arm including Single Top Support Brace and Insulator fixingNo269.85269.854.0FalseNoneNoneFalseNoneFalse1079.40
265922382774NoneElecl code167Gescom SR/SSM 11KV/47/6.01.11 kV Ceramic Pin Insulator (Shell only)No87.1587.1512.0FalseNoneNoneFalseNoneFalse1045.80
265922482774NoneElecl code168Gescom SR/SSM 11KV/55/6.09.DISC Insulator 45 kN PorcelainNo535.5535.512.0FalseNoneNoneFalseNoneFalse6426.00
265922582774NoneElecl code169Gescom SR/SSM 11KV/166/24.01.11 kV, 200 Amps Single Break GOS (Dwg No. BESCOM/GM/QS&S/23 Dtd 24.11.2018)No9922.59922.51.0FalseNoneNoneFalseNoneFalse9922.50
265922682774NoneElecl code170Gescom SR/11KV Labour/97/13.02.Fixing of GOS including wiring (11 kV Single Break 200 Amps)No1159.21159.21.0FalseNoneNoneFalseNoneFalse1159.20
265922782774NoneElecl code171Gescom SR/SSM 11KV/39/5.09, 5.11, 5.12, 5.13, 5.14, 5.16. Guy Clamp - MS (Dwg No. BESCOM/GM/QS&S/07 Dtd 24.11.2018)Turn Buckle (GI) (Dwg No. BESCOM/GM/QS&S/07 Dtd 24.11.2018)Anchor Rod using 12 mm rounds/Guy Rod - MS (Dwg No. BESCOM/GM/QS&S/07 Dtd 24.11.2018)MS Fish Plate Strain Clamp, 3 Bolt type for 70/90 kN Disc InsulatorNo1785.01785.03.0FalseNoneNoneFalseNoneFalse5355.00
265922882774NoneElecl code172Gescom SR/11KV Labour/58/5.10.Fixing of GUY Set with break insulator making use of 7/3.15 mm (7/10 SWG) galvanised steel wire with turn buckle and anchoring arrangement as per approved drawing. (Excluding excavation of PIT)No279.3279.33.0FalseNoneNoneFalseNoneFalse837.90
265922982774NoneElecl code173Gescom SR/SSM 11KV/137/19.01. 9 kV, 5 kA Lightning Arrester Metal Oxide Ceramic type with GROUND DISCONNECTOR (Dwg No. BESCOM/GM/QS&S/26 Dtd 24.10.2007)Set966.0966.01.0FalseNoneNoneFalseNoneFalse966.00
265923082774NoneElecl code174Gescom SR/11KV Labour/101/13.06.Fixing of 3 Nos Lightning Arrestor including wiringSet124.95124.951.0FalseNoneNoneFalseNoneFalse124.950
265923182774NoneElecl code175Gescom SR/SSM 11KV/139/20.01.11 kV, HG Fuse Unit with Solid Core Insulator (Dwg No. BESCOM/GM/QS&S/21 Dtd 24.11.2018)Set1122.451122.451.0FalseNoneNoneFalseNoneFalse1122.450
265923282774NoneElecl code176Gescom SR/11KV Labour/96/13.01.Fixing DOLO Cutout/Horn Gap Fuse including fixing of cross arm and wiringSet248.85248.851.0FalseNoneNoneFalseNoneFalse248.850
265923382774NoneElecl code177Gescom SR/SSM 11KV/59/7.02.Rabbit ACSR (6/3.35 mm Al + 1/3.35 mm St), Std Wt. 214 Kg/KMKm48545.748545.70.2FalseNoneNoneFalseNoneFalse9709.140
265923482774NoneElecl code17815.111.Supplying of four bucket stand alongwith buckets. CompleteNo1942.51942.52.0FalseNoneNoneFalseNoneFalse3885.00
265923582774NoneElecl code17915.117.Supplying and installation of RUBBER MAT 1mtr x 1mtr -1Omm thick.complete including cost of materials, labour, usage charges of machinery complete as per specifications.No1995.01995.02.0FalseNoneNoneFalseNoneFalse3990.00
265923682774NoneElecl code18015.113.Supplying of Hand gloves. completePair1023.751023.752.0FalseNoneNoneFalseNoneFalse2047.50
265923782774NoneElecl code18115.114.Supplying of first aid box. completeNo630.0630.02.0FalseNoneNoneFalseNoneFalse1260.00
265923882774NoneElecl code18215.116.Supplying of FIRST AID CHART with lamination. CompleteNo420.0420.02.0FalseNoneNoneFalseNoneFalse840.00
265923982774NoneElecl code183Ges SR/SSM 11KV/593/68.17.Caution/Danger BoardNo157.5157.56.0FalseNoneNoneFalseNoneFalse945.00
265924082774NoneElecl code18421-22/Vol-4/Part-B/Liftrrigation/4.41.Providing and fixing chain link fencing consisting of 3 m long 65 x 65 x 6 mm M.S angles with top 50 cm bent at 30 degree to vertical fixed at 2.5 m intervals in C.C 1 . 3 . 6 proportion using 20 mm down graded coarse aggregate for 70 cm depth, fixing 50 x 50 mm opening 8 gauge G.I chain link mesh upto 1.8 m height of poles using 8 gauge stretcher wire at top and bottom and 30 x 30 x 5 mm M.S angles with bolts /nuts / washers ( 4 bolts for each pole ), fixing 3 rows of 12 gauge ( 4 barbs at 7.5 cm c/c ) G.I barbed wire for top bent portion of poles, including cost of all materials, machinery, labour, excavation of pit, mixing and laying concrete, curing, drilling holes in angles, cleaning angles, painting angles and Chain links with 2 coats of synthetic enamel paint over a coat of primer etc., complete with all lead and lifts.Sqm1444.81444.824.0FalseNoneNoneFalseNoneFalse34675.20
265924182774NoneElecl code1855.20.2.Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board.No4786.954786.951.0FalseNoneNoneFalseNoneFalse4786.950
265924282774NoneElecl code186Do- 63 Amps 4 pole (5.20.3)No5520.95520.91.0FalseNoneNoneFalseNoneFalse5520.90
265924382774NoneElecl code187Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts,nuts etc., with provision for fixing suitable type capacity MCBfeets single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.5.19.6 4Way SP &NNo1600.21600.210.0FalseNoneNoneFalseNoneFalse16002.00
265924482774NoneElecl code188Do- 8way SP &N.(5.19.8) Double door.No1946.71946.72.0FalseNoneNoneFalseNoneFalse3893.40
265924582774NoneElecl code189Do- 12way SP &N. (5.19.9) Double door.No2445.452445.452.0FalseNoneNoneFalseNoneFalse4890.90
265924682774NoneElecl code1905.29.Supplying, fixing and wiring 3 Phase Digital Ammeter /Voltmeter.No1496.251496.251.0FalseNoneNoneFalseNoneFalse1496.250
265924782774NoneElecl code191Supplying, fixing and wiring 50/5Amps to 400/5 Amps 5VA burden current transformer. 0.5 accuracy. (5.34)No590.1590.16.0FalseNoneNoneFalseNoneFalse3540.60
265924882774NoneElecl code192Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v AC 50Hz 12/24v DC (5.38)No540.75540.756.0FalseNoneNoneFalseNoneFalse3244.50
265924982774NoneElecl code193PWD SR/Vol-2/11.16.1.Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg142.8142.8200.0FalseNoneNoneFalseNoneFalse28560.00
265925082774NoneElecl code19412.57.Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.12.57No4468.84468.84.0FalseNoneNoneFalseNoneFalse17875.20
265925182774NoneElecl code195Gescom SR/SSM 11KV/61/8.02.8 SWG GI Wire (4.064 mm Dia), Std Wt. 131 Kg/KMKm78792.078792.00.04FalseNoneNoneFalseNoneFalse3151.680
265925282774NoneElecl code196Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.25x3mm GI strip 12.58.1Mtr86.186.120.0FalseNoneNoneFalseNoneFalse1722.00
265925382774NoneElecl code197Gescom sr/SSM 11KV/207/32.11. 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 50 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm)Km187921.65187921.650.3FalseNoneNoneFalseNoneFalse56376.4950
265925482774NoneElecl code198Gescom sr/11KV Labour/176/21.06. Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 to 95 SqmmKm32695.9532695.950.3FalseNoneNoneFalseNoneFalse9808.7850
265925582774NoneElecl code199Vol I/1.14.1.Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1Cum107.1107.199.0FalseNoneNoneFalseNoneFalse10602.90
265925682774NoneElecl code200Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes.6.17.1 (2019-20 SR)No3.153.1560.0FalseNoneNoneFalseNoneFalse189.00
265925782774NoneElecl code201Do- 2.5 sqmm. (6.17.2)No4.24.280.0FalseNoneNoneFalseNoneFalse336.00
265925882774NoneElecl code202Do- 4.0 sqmm. (6.17.3)No7.357.3523.0FalseNoneNoneFalseNoneFalse169.050
265925982774NoneElecl code203Do- 6 sqmm. (6.17.4)No7.357.3524.0FalseNoneNoneFalseNoneFalse176.40
265926082774NoneElecl code204Do- 10sqmm.(6.17.5)No8.48.424.0FalseNoneNoneFalseNoneFalse201.60
265926182774NoneElecl code205Do- 16 sqmm. (6.17.6)No13.0613.0612.0FalseNoneNoneFalseNoneFalse156.720
265926282774NoneElecl code206Do- 50 sqmm Long Barrel. (6.17.9)No63.063.016.0FalseNoneNoneFalseNoneFalse1008.00
265926382774NoneElecl code207Vol V/191/16.9.onstructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1.6, bed concrete 150mm thick with 1.3.6, plastering 12 mm thick with cement mortar 1.4, CC 1.2.4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.No5726.75726.74.0FalseNoneNoneFalseNoneFalse22906.80
265926482774NoneElecl code208Vol V/10.1.8.Providing PVC ringtite pipes conforming to IS 4985.2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete 110mmRmtr431.55431.55142.0FalseNoneNoneFalseNoneFalse61280.10
265926582774NoneElecl code209Vol II/09/5.4.(Size stone masonry) Construction of Platform with size stone, cement concrete for errection of Transformer/Metering Cubicle /Heavy equipment. Construction of platform [1.5m x 1.5m x 1.2m] in size srone , for errection of transformer /Heavy equipment including all materials , labour Excavation of [1.5mx1.5mx1m] pit for foundation providing and laying cement concrete 1.4.8 for foundation laid in 10cm thick layers, well compacted curing etc, complete providing and construction of stone masonary 0.9m below ground level and 1.2m above ground level neatly hammer dressed in cement morter 1.6 Providing and Laying cement concrete slab 1.5x1.5x.10mtr with cement concrete of 1.2.4 mix forming & cutting complete , providing pointing to stone masonary in cement morter 1.3 after rackng joint & nisely lining curing etc, plastering the concrete surfaces in cement morter 1.4 including smooth randering curing etc, curing at every stages completely.Cum6708.456708.452.7FalseNoneNoneFalseNoneFalse18112.8150
265926682774NoneElecl code210Gescom SR/SSM 11KV/398/53.04.LT AC 3 Phase 4 Wire, 5-30 Amps DLMS Complaint Energy Meter, 1.0 Accuracy Class (Used for LT-2, LT-3 & LT-5 Installations up to 25HP/18KW)Each2499.02499.01.0FalseNoneNoneFalseNoneFalse2499.00
265926782774NoneElecl code2114.1.1.Fabricating, supplying and erecting Swaged tubular Pole of height ...m having three sections, and providing two coats of red oxide paint and finished with two coats of enamelled paint of approved quality and colour and M.S. base plate of suitable size welded at the bottom of the Pole(as per IS) and 40 mm dia GI/flexible PVC pipe of 1m length fitted to the heavy gauge polycarbonate control box including 5 Way connector of size 167 x 125 x 82 mm for 7.5M Pole/ 200 x 160 x 98 mm for remaining length of Pole with front opening cover, with locking arrangements and suitable capacity MCB/DP switch, The Pole shall be erected in cement concrete work (1.2.4) including excavation and refilling of planting depth of the Pole to the ground level and the coping CC shall be upto 0.6m above ground level as per IS2713-7.Erection of heavy duty Pole on Footpath/median 9m (5m Hb,165.1 mm dia 4.85 mm thick x 2m Hm, 139.7 mm dia 4.50 mm thick x 2m Ht,114.3 mm dia 3.65 mm thick) as per IS 410 SP 32No16275.016275.012.0FalseNoneNoneFalseNoneFalse195300.00
265926882774NoneElecl code21212.8.4 Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70Percentage, maximum light intensity should be between 60 degrees to 70 degrees. CCT morethan 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire morethan IK08. Power Factor morethan0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiencymorethan130lm/w, nominal CRI morethan75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001.2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/Lumileds/Osram make LED Source.LED Streetlight 90 WattsNo9303.09303.012.0FalseNoneNoneFalseNoneFalse111636.00
265926982774NoneElecl code213Gescom sr/SSM 11KV/198/32.02. 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 10 Sqmm, 2 Core, (9 GI Strips - 4 x 0.8 mm)Km83193.683193.60.4FalseNoneNoneFalseNoneFalse33277.440
265927082774NoneElecl code214Gescom sr/11KV Labour/175/21.05. Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 to 25 SqmmKm21930.321930.30.4FalseNoneNoneFalseNoneFalse8772.120
265927182774NoneElecl code215Vol I/1.14.1.Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1Cum107.1107.1120.0FalseNoneNoneFalseNoneFalse12852.00
265927282774NoneElecl code216Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes.6.17.5 (2019-20 SR)10sqmm.No8.48.480.0FalseNoneNoneFalseNoneFalse672.00
265927382774NoneElecl code217Vol V/10.1.8.Providing PVC ringtite pipes conforming to IS 4985.2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete 110mmMtr431.55431.55120.0FalseNoneNoneFalseNoneFalse51786.00
265927482774NoneElecl code21811.1.Supplying & fixing - flexible LED Strip Light ..... W Power consumption in 5 ms length CCT6500 degree K, CRImorethan 70Percentage. efficacy morethan80 lumen per W, lifemorethan 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver non integrated, with PF morethan 0.95, power loss shouldLess than 5Percentage of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20Percentage, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved with 2 years Warranty against any manufacturing defect working under standard electrical condition.Rmtr1355.551355.55239.0FalseNoneNoneFalseNoneFalse323976.450
265927582774NoneElecl code2193.8.Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screws (Unit Sqcm)Sqm0.430.43160000.0FalseNoneNoneFalseNoneFalse68800.00
265927682774NoneElecl code220PWD SR/2023-24/Vol-II/Material Components/A-12/ii/23.Aluminium Composite of approved colour straight portion.Sqm3150.03150.016.0FalseNoneNoneFalseNoneFalse50400.00
265927782774NoneElecl code221PWD SR/2023-24/Vol-II/7.64.1.1.Aluminium fluted strips 3.15 mm thick.150 mm wide (but used 50 mm wide hence Rs.557/3=185.66 taken)Rmtr194.94194.94120.0FalseNoneNoneFalseNoneFalse23392.80
265927882774NoneElecl code222PWD SR/2023-24/Vol-II/10.15.1.Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., completeCum4188.454188.4512.0FalseNoneNoneFalseNoneFalse50261.40
265927982774NoneElecl code2235.41.4.Supplying and fixing angle iron frame work fabricated out of M.S.angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.50 x 100 x 50 x 6 mm C channel (but used 25x50 mm square pipe) hence 0.65 takenMtr515.97515.9736.0FalseNoneNoneFalseNoneFalse18574.920
265928082774NoneElecl code2245.47.Supplying and fixing Microprocessor based Electronic timer (without contactor, Din Mounting using necessary bolts, nuts and washers etc.) 3-120sec setting.Each2430.752430.752.0FalseNoneNoneFalseNoneFalse4861.50
265928182774NoneElecl code2255.13.2.Supply and fixing of 3pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947.40 AEach2370.92370.91.0FalseNoneNoneFalseNoneFalse2370.90
265928282774NoneElecl code2265.13.3.Supply and fixing of 3pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947.60 AEach6247.56247.51.0FalseNoneNoneFalseNoneFalse6247.50
265928382774NoneElecl code227PWD SR/2023-24/Vol-I/A-40/77.Mild Steel Tubes 14 guage 1inch x 1inch squire pipeKg63.063.0300.0FalseNoneNoneFalseNoneFalse18900.00
265928482774NoneElecl code228PWD SR/2023-24/Vol-III/8.7/801.Direction and Place Identification Signs upto 0.9 m2 Size Board.Providing and erecting direction and place identification retroreflectorised sign as per IRC.67.2022 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick or Aluminium composite material sheet with overall thickness of 4mm with area not exceeding 0.9 m2 fixed over back support frame of min 35 x 35 x 3mm angle mounted on a mild steel circular pipe 65 NB, firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawingSqm9460.59460.58.2FalseNoneNoneFalseNoneFalse77576.10
265928582774NoneElecl code229PWD SR/2023-24/Vol-II/11.28.Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge,(for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg593.25593.25120.0FalseNoneNoneFalseNoneFalse71190.00
265928682774NoneElecl code230PWD SR/2023-24/Vol-III/8.43.Supplying and Fixing of Molded Shank Raised Pavement Markers / Catfeets Eye made of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kg tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No RW/NH/33023/10-97 DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 mm, 100 mm and 102 +/- 2 mm and with minimum reflective area of 13 cm2 on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than19 +/- 2 mm and height not less than30+/- 2 mm) from the body is to be a minimum value of 500 Kg. Fixing will be bydrilling holes on the road for the shanks to go inside,without nails and using epoxy resin based adhesive as per manufacturerfeets recommendation and complete as directed by the engineer.The contractor shall submit a two year warranty for satisfactory field performance including stipulated retro-reflectance of the reflecting panel, to the Engineer.Each383.25383.2570.0FalseNoneNoneFalseNoneFalse26827.50
265928782774NoneElecl code231PWD SR/2023-24/Vol-III/8.45.Providing Vertical Delineator having wide angle cube corner micro prismatic non metallic reflective sheeting confirming to Type XI of ASTM D4956 -09 with White Color and Red Color combination and having minimum of retro reflective exposed area of 125 Sq CM on top slots and 35 cm2 on bottom slots and no edges shall be exposed for tampering. This tubular delineator shall have a core and shell construction, shell shall be made of tough, high impact resistant, injection-molded, thermoplastic outer body and the inner core shall consist of powder coated or painted Mild steel of minimum thickness 1.0mm.and coreshell structure shall be of height not less than 800 mm above the ground and width not less than 80 mm. The metallic core of the delineator shall extend 300mm beyond the shell length from bottom for installing in the ground. The extended portion shall have slots to insert anchoring rods for enhancing the concrete grip. The logo of the manufacturer shall be embossed on either side of the body in the injection molding process.The engineering thermoplastic used for making the delineator body shall have minimum initial mechanical properties of be fixed by a combination of epoxy adhesive and grouting as per MoRTH specification 806Each3045.03045.010.0FalseNoneNoneFalseNoneFalse30450.00
265928882774NoneElecl code232PWD SR/2023-24/Vol-III/8.15.Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 g/m2 area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC.35.2015.The finished surface to be level,uniform and free from streaks and holes.Sqm556.5556.5100.0FalseNoneNoneFalseNoneFalse55650.00
265928982774NoneElecl code233PWD SR/2023-24/Vol-III/8.53.Providing & fixing Polymer rubberised factory made Black & Yellow coloured Speed retarders/Breakers with width 350mm & Height 50mm as per IRC 99.2018 with load carrying capacity upto 30t in local streets, parking arena and in areas with speed limit of 20 kmph as per direction of Engineer in-charge.Mtr945.0945.046.0FalseNoneNoneFalseNoneFalse43470.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17080890090000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17080890090000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17080890090000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17080891350000NoneNoneELIGIBILITYShould be a valid Class-I Civil Contractor registered in Karnataka CPWD/MES/KPWD (Upload Registration Certificate for the block period 2020-25.)None
17080891650000NoneNoneELIGIBILITYShould have successfully completed at least one work of similar nature of building work, costing not less than Rs. 182.50 lakhs (Rs. one hundred eighty two lakh & fifty thousand) i.e from 01/04/2018 onwards for any of the Govt. Public Sector Corporate undertakings. (Certificate of completion issued by an officer not below the rank of Executive Engineer, in case of Govt., / Public Sectors under takings.)None
17080895950001NoneNoneELIGIBILITYAttach the documents as per tender NotificationNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneAs per attached tender notificationOthersAttach the documents as per tender notification
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Attach the documents as per tender notification
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateFalseTechnical Bid
Company Registration CertificateFalseTechnical Bid
Small Scale Industries CertificateFalseTechnical Bid
Attach the documents as per tender notificationTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1708092172000
version0
createdDateNone
modifiedDateNone
blockNumberKKRTC Kalaburagi
streetNone
cityKalaburagi
stateKarnataka
pin585102
tenderRecallDTONone