createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1707985044513
version8
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd380000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose29-02-2024 16:00:00
tenderQueryClose21-02-2024 14:30:00
technicalBidOpen01-03-2024 16:00:01
publishedDate16-02-2024 12:36:31
publishedByPostEWHFWD_CE_CEOFF_BNG
publishedByUserKPE16838 - BALEKATTE KUMARASWAMY PAVITHRA
bidValidityPeriod90
noOfCalls1
preBidMeetingDate22-02-2024 11:30:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonTechnical Assistant.
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08029557023
mobileNumber9449843294
tenderSupplierListNone
tenderSchedule
createdTs1707985044540
version18
createdDateNone
modifiedDateNone
tenderNumberEWHFWD/2023-24/BD/WORK_INDENT96
titleUp-gradation of infrastructure facilities to the TLH at Chikkodi in Belagavi District,2)Construction of STP works to CHC at Ankali in Chikkodi taluk, Belagavi District.3)Up-gradation of infrastructure facilities to the TLH at Ramdurga in Belagavi District.(Pkg-14/2023-24)
descriptionUp-gradation of infrastructure facilities to the TLH at Chikkodi in Belagavi District,2)Construction of STP works to CHC at Ankali in Chikkodi taluk, Belagavi District.3)Up-gradation of infrastructure facilities to the TLH at Ramdurga in Belagavi District.(Pkg-14/2023-24)
categoryWORKS
categoryTextWorks
ecv25229688.21
deptNameEngineering Wing of Health and Family Welfare Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location3521
locationNameEWHFWD Chief Engineer Office Bengaluru
provisionalAmount25300000.0
groupOverheadTotal0.0
fileNumberAEE/BGM/2023-24/01-133
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17079850450001NoneNoneBuildingsUp-gradation of infrastructure facilities to the TLH at Chikkodi in Belagavi District.(Slice-1)12933298.21
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
260133181144NoneV-2 Item No 19.22.2Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction of Engineer-in-charge25 mm and up to 40 mm ---- etc., complete with all leadSqm89.9389.931262.086FalseNoneNoneFalseNoneFalse113499.393980
260133281144NoneV-2 Item No 2.4.1Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum9340.19340.12.0FalseNoneNoneFalseNoneFalse18680.20
260133381144NoneV-2 Item No 20.93Cleaning Quadrangle chajjas including removing of dirt dust etc., using suitrable soap powder , coconut broomstick, squeezers / wipers/ rubber brushes, coir brushes, plastric brushjes, mugs, booster pumps with portable arrangement, hose pipe etc., compl ---- etc., complete with all leadSqm18.2318.2369.25FalseNoneNoneFalseNoneFalse1262.42750
260133481144NoneV-2 Item No 8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm309.92309.921066.098FalseNoneNoneFalseNoneFalse330405.092160
260133581144NoneV-2 Item No 9.12.2Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm ---- etc., complete with all leadSqm1391.631391.63200.965FalseNoneNoneFalseNoneFalse279668.922950
260133681144NoneV-2 Item No 9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. ---- etc., complete with all leadSqm3466.323466.32104.82FalseNoneNoneFalseNoneFalse363339.66240
260133781144NoneV-2 Item No 9.23Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cat Eye, River Pink or equivalent. ---- etc., complete with all leadSqm2997.172997.1730.72FalseNoneNoneFalseNoneFalse92073.06240
260133881144NoneV-2 Item No 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. ---- etc., complete with all leadSqm1080.491080.49166.075FalseNoneNoneFalseNoneFalse179442.376750
260133981144NoneV-2 Item No 9.38Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete with all leadSqm1691.831691.831066.098FalseNoneNoneFalseNoneFalse1803656.579340
260134081144NoneV-2 Item No 20.47Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge ---- etc., complete with all leadEach365.83365.835.0FalseNoneNoneFalseNoneFalse1829.150
260134181144NoneV-2 Item No 8.57Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all leadSqm15.815.83805.92FalseNoneNoneFalseNoneFalse60133.5360
260134281144NoneV-2 Item No 8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge ---- etc., complete with all leadSqm450.91450.91175.0FalseNoneNoneFalseNoneFalse78909.250
260134381144NoneV-2 Item No 8.63Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: One coats on old work as per specifications and as per directions of Engineer in charge. ---- etc., complete with all leadSqm99.6699.663805.92FalseNoneNoneFalseNoneFalse379297.98720
260134481144NoneV-2 Item No 8.75.1Finishing walls with Premium Acrylic Smooth exterior paint of required shade : Old work (Two coats applied @ 1.43 l/ 10 m²) over existing cement paint surface including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge ---- etc., complete with all leadSqm134.9134.93000.95FalseNoneNoneFalseNoneFalse404828.1550
260134581144NoneV-2 Item No 12.11Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete with all leadCum167815.13167815.130.45FalseNoneNoneFalseNoneFalse75516.80850
260134681144NoneV-2 Item No 12.57.5Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. 35 mm thick one side teak and one side commercial ---- etc., complete with all leadSqm4736.414736.4112.6FalseNoneNoneFalseNoneFalse59678.7660
260134781144NoneV-2 Item No 12.83.2Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance plus or minus 1mm), with wall thickness 2.0 mm (plus or minus 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (plus or minus 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineer- in-charge.42x50 mm PVC Extruded section ---- etc., complete with all leadm290.48290.4869.3FalseNoneNoneFalseNoneFalse20130.2640
260134881144NoneV-2 Item No 12.55.1Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. with both side prelam ---- etc., complete with all leadSqm2875.632875.6322.05FalseNoneNoneFalseNoneFalse63407.64150
260134981144NoneV-2 Item No 7.64.1.2Providing and fixing sheet covering over expansion joints with iron screwsas per design.200 mm wide ---- etc., complete with all leadm881.16881.167.8FalseNoneNoneFalseNoneFalse6873.0480
260135081144NoneV-2 Item No 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all leadNo1234.841234.845.0FalseNoneNoneFalseNoneFalse6174.20
260135181144NoneV-2 Item No 11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all leadKg686.7686.734.5FalseNoneNoneFalseNoneFalse23691.150
260135281144NoneV-2 Item No 12.69.212.69.20 Providing and fixing ISI marked oxidised M.S. single acting spring hinges with necessary screws etc.125mm ---- etc., complete with all leadNo295.34295.3480.0FalseNoneNoneFalseNoneFalse23627.20
260135381144NoneV-2 Item No 444Providing and fixing Hold fasts ---- etc., complete with all leadNo60.7660.7685.0FalseNoneNoneFalseNoneFalse5164.60
260135481144NoneV-2 Item No 12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete ---- etc., complete with all leadNo288.04288.0440.0FalseNoneNoneFalseNoneFalse11521.60
260135581144NoneV-2 Item No 12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. ---- etc., complete with all leadNo145.84145.845.0FalseNoneNoneFalseNoneFalse729.20
260135681144NoneV-2 Item No 12.6Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete with all leadNo1278.61278.65.0FalseNoneNoneFalseNoneFalse6393.00
260135781144NoneV-2 Item No 12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete ---- etc., complete with all leadNo158.0158.020.0FalseNoneNoneFalseNoneFalse3160.00
260135881144NoneV-2 Item No 14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid ---- etc., complete with all leadEach7264.447264.4412.0FalseNoneNoneFalseNoneFalse87173.280
260135981144NoneV-2 Item No 14.1.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests ---- etc., complete with all leadEach5936.015936.0113.0FalseNoneNoneFalseNoneFalse77168.130
260136081144NoneV-2 Item No 14.7.8Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow including operated levers ---- etc., complete with all leadEach4998.944998.9415.0FalseNoneNoneFalseNoneFalse74984.10
260136181144NoneV-2 Item No 14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer in-charge. ---- etc., complete with all leadEach984.47984.4715.0FalseNoneNoneFalseNoneFalse14767.050
260136281144NoneV-2 Item No 14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. ---- etc., complete with all leadEach6760.056760.0515.0FalseNoneNoneFalseNoneFalse101400.750
260136381144NoneV-2 Item No 14.29Providing and fixing 100 mm sand cast Iron grating for gully trap. ---- etc., complete with all leadEach57.1257.1215.0FalseNoneNoneFalseNoneFalse856.80
260136481144None18-19 SR Item No 12.113.2Providing and fixing Cl Nahani trap of approved make conforming to lSI specifications and construction of Cistern in M-15 as per directions (Rate is inclusive of cost of materials and fixtures and conveyance of materials to work spot).12.5mmx75mm ---- etc., complete with all leadEach249.15249.1515.0FalseNoneNoneFalseNoneFalse3737.250
260136581144NoneV-2 Item No 14.36.2Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 g ---- etc., complete with all leadEach113.03113.0315.0FalseNoneNoneFalseNoneFalse1695.450
260136681144NoneV-5 Item No 10.1.7Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc.complete for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 ---- etc., complete with all leadm499.52499.5250.0FalseNoneNoneFalseNoneFalse24976.00
260136781144NoneV-5 Item No 10.1.8Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc.complete for: PVC pipes 140mm dia., 6 kg/sqcm & class 3 ---- etc., complete with all leadm709.79709.7930.0FalseNoneNoneFalseNoneFalse21293.70
260136881144NoneV-2 Item No 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm dia ---- etc., complete with all leadm375.55375.5550.0FalseNoneNoneFalseNoneFalse18777.50
260136981144NoneV-2 Item No 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm dia ---- etc., complete with all leadm460.63460.6370.0FalseNoneNoneFalseNoneFalse32244.10
260137081144NoneV-2 Item No 13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm dia ---- etc., complete with all leadm579.74579.7450.0FalseNoneNoneFalseNoneFalse28987.00
260137181144NoneV-2 Item No 13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32mm dia ---- etc., complete with all leadm676.97676.9740.0FalseNoneNoneFalseNoneFalse27078.80
260137281144NoneV-2 Item No 19.43.1Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes to the appropriate disposal area as per direction of Engineer-in-charge.15 mm to 40 mm nominal bore ---- etc., complete with all leadm126.4126.4400.0FalseNoneNoneFalseNoneFalse50560.00
260137381144NoneV-2 Item No 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. ---- etc., complete with all leadl10.9310.935000.0FalseNoneNoneFalseNoneFalse54650.00
260137481144NoneV-5 Item No 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.. ---- etc., complete with all leadNo6628.796628.7910.0FalseNoneNoneFalseNoneFalse66287.90
260137581144NoneV-6 Item No 1.8.1Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm .... etc. as required. 20 mm ---- etc., complete with all leadm34.0334.031250.0FalseNoneNoneFalseNoneFalse42537.50
260137681144NoneV-6 Item No 1.8.2Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm .... etc. as required. 25 mm ---- etc., complete with all leadm42.5342.531500.0FalseNoneNoneFalseNoneFalse63795.00
260137781144NoneV-6 Item No 2.2.1POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3 mts from tapping point to out let via switch box ---- etc., complete with all leadPoint326.94326.9440.0FalseNoneNoneFalseNoneFalse13077.60
260137881144NoneV-6 Item No 2.2.2POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3 mts upto 6mts from tapping point to outlet via switch box ---- etc., complete with all leadPoint460.63460.6345.0FalseNoneNoneFalseNoneFalse20728.350
260137981144NoneV-6 Item No 2.2.3POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6 mts upto 10 mts from tapping point to outlet via switch box ---- etc., complete with all leadPoint674.54674.5430.0FalseNoneNoneFalseNoneFalse20236.20
260138081144NoneV-6 Item No 2.2.4POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row above 3mts upto 6 mts from tapping point to outlet via switches ---- etc., complete with all leadPoint822.82822.822.0FalseNoneNoneFalseNoneFalse1645.640
260138181144NoneV-6 Item No 2.2.5POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row above 6 mts upto 10 mts from the tapping point to outlet via switches ---- etc., complete with all leadPoint1202.031202.032.0FalseNoneNoneFalseNoneFalse2404.060
260138281144NoneV-6 Item No 2.3.1Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 1 mm2 ---- etc., complete with all leadm23.0923.092800.0FalseNoneNoneFalseNoneFalse64652.00
260138381144NoneV-6 Item No 2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 1.5 mm2 ---- etc., complete with all leadm31.631.62200.0FalseNoneNoneFalseNoneFalse69520.00
260138481144NoneV-6 Item No 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 2.5 mm2 ---- etc., complete with all leadm51.0451.041600.0FalseNoneNoneFalseNoneFalse81664.00
260138581144NoneV-6 Item No 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 4 mm2 ---- etc., complete with all leadm76.5776.57400.0FalseNoneNoneFalseNoneFalse30628.00
260138681144NoneV-6 Item No 2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 6 mm2 ---- etc., complete with all leadm111.81111.81600.0FalseNoneNoneFalseNoneFalse67086.00
260138781144NoneV-6 Item No 3.3.1Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 1-2 Way ---- etc., complete with all leadEach125.18125.1812.0FalseNoneNoneFalseNoneFalse1502.160
260138881144NoneV-6 Item No 3.3.2Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 3 Way ---- etc., complete with all leadEach150.7150.712.0FalseNoneNoneFalseNoneFalse1808.40
260138981144NoneV-6 Item No 3.3.3Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 4-5 Way ---- etc., complete with all leadEach166.5166.510.0FalseNoneNoneFalseNoneFalse1665.00
260139081144NoneV-6 Item No 3.3.4Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 6 Way ---- etc., complete with all leadEach210.26210.2610.0FalseNoneNoneFalseNoneFalse2102.60
260139181144NoneV-6 Item No 3.3.5Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 8 Way ---- etc., complete with all leadEach266.17266.1710.0FalseNoneNoneFalseNoneFalse2661.70
260139281144NoneV-6 Item No 3.3.6Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 10-12 Way ---- etc., complete with all leadEach317.21317.218.0FalseNoneNoneFalseNoneFalse2537.680
260139381144NoneV-6 Item No 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal/PVC box 1 to 2Module ---- etc., complete with all leadEach166.5166.512.0FalseNoneNoneFalseNoneFalse1998.00
260139481144NoneV-6 Item No 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal/PVC box 3Module ---- etc., complete with all leadEach195.67195.6712.0FalseNoneNoneFalseNoneFalse2348.040
260139581144NoneV-6 Item No 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal/PVC box 4 Module ---- etc., complete with all leadEach212.69212.6910.0FalseNoneNoneFalseNoneFalse2126.90
260139681144NoneV-6 Item No 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal/PVC box 6 Module ---- etc., complete with all leadEach284.4284.410.0FalseNoneNoneFalseNoneFalse2844.00
260139781144NoneV-6 Item No 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal/PVC box 8 Module ---- etc., complete with all leadEach345.17345.1710.0FalseNoneNoneFalseNoneFalse3451.70
260139881144NoneV-6 Item No 3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal/PVC box 10/12 Module ---- etc., complete with all leadEach418.09418.095.0FalseNoneNoneFalseNoneFalse2090.450
260139981144NoneV-6 Item No 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6 amps one way switch ---- etc., complete with all leadEach123.97123.978.0FalseNoneNoneFalseNoneFalse991.760
260140081144NoneV-6 Item No 3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6 amps two way switch ---- etc., complete with all leadEach201.75201.758.0FalseNoneNoneFalseNoneFalse1614.00
260140181144NoneV-6 Item No 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6 Amps 3 way sockets ---- etc., complete with all leadEach207.83207.8312.0FalseNoneNoneFalseNoneFalse2493.960
260140281144NoneV-6 Item No 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. stepped fan Regulator's Two module ---- etc., complete with all leadEach433.89433.8910.0FalseNoneNoneFalseNoneFalse4338.90
260140381144NoneV-6 Item No 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16 Amps universal sockets ---- etc., complete with all leadEach286.83286.8312.0FalseNoneNoneFalseNoneFalse3441.960
260140481144NoneV-6 Item No 3.6.7Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16 Amps one way Switch ---- etc., complete with all leadEach218.77218.776.0FalseNoneNoneFalseNoneFalse1312.620
260140581144NoneV-6 Item No 3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TV/Telephone socket ---- etc., complete with all leadEach189.6189.61.0FalseNoneNoneFalseNoneFalse189.60
260140681144NoneV-6 Item No 3.14.14 Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 6A SP Switch ---- etc., complete with all leadEach66.8466.8412.0FalseNoneNoneFalseNoneFalse802.080
260140781144NoneV-6 Item No 3.14.24 Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 6A Two Way Switch ---- etc., complete with all leadEach85.0785.0715.0FalseNoneNoneFalseNoneFalse1276.050
260140881144NoneV-6 Item No 3.14.34 Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 6A Three Way 5 Pin Socket ---- etc., complete with all leadEach85.0785.0715.0FalseNoneNoneFalseNoneFalse1276.050
260140981144NoneV-6 Item No 3.14.44 Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 6A Three Pin Top ---- etc., complete with all leadEach105.73105.7312.0FalseNoneNoneFalseNoneFalse1268.760
260141081144NoneV-6 Item No 3.14.54 Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 6A Bakelite Ceiling Rose ---- etc., complete with all leadEach94.894.812.0FalseNoneNoneFalseNoneFalse1137.60
260141181144NoneV-6 Item No 3.14.64 Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 6A Pendant Holder ---- etc., complete with all leadEach86.2986.2912.0FalseNoneNoneFalseNoneFalse1035.480
260141281144NoneV-6 Item No 3.14.74 Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 6A Batten Holder ---- etc., complete with all leadEach89.9389.932.0FalseNoneNoneFalseNoneFalse179.860
260141381144NoneV-6 Item No 3.14.84 Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 6A Bell Push ---- etc., complete with all leadEach85.0785.0710.0FalseNoneNoneFalseNoneFalse850.70
260141481144NoneV-6 Item No 3.14.94 Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 6A Bell Buzzer ---- etc., complete with all leadEach158.0158.012.0FalseNoneNoneFalseNoneFalse1896.00
260141581144NoneV-6 Item No 3.14.104 Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 16A SP Switch ---- etc., complete with all leadEach159.21159.214.0FalseNoneNoneFalseNoneFalse636.840
260141681144NoneV-6 Item No 3.14.114 Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 16A Two Way Switch ---- etc., complete with all leadEach177.44177.4412.0FalseNoneNoneFalseNoneFalse2129.280
260141781144NoneV-6 Item No 3.14.124 Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 16A Three Way 5 Pin Socket ---- etc., complete with all leadEach139.77139.773.0FalseNoneNoneFalseNoneFalse419.310
260141881144NoneV-6 Item No 3.14.134 Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 16A Three Pin Top ---- etc., complete with all leadEach133.69133.694.0FalseNoneNoneFalseNoneFalse534.760
260141981144NoneV-6 Item No 3.14.144 Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 32A Bakelite DP ---- etc., complete with all leadEach281.97281.974.0FalseNoneNoneFalseNoneFalse1127.880
260142081144NoneV-6 Item No 3.14.154 Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 16/6A combined plug and socket with control switch ---- etc., complete with all leadEach264.95264.953.0FalseNoneNoneFalseNoneFalse794.850
260142181144NoneV-6 Item No 3.14.164 Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board Electronic stepped regulator. ---- etc., complete with all leadEach341.52341.523.0FalseNoneNoneFalseNoneFalse1024.560
260142281144NoneV-6 Item No 5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP ---- etc., complete with all leadEach504.39504.3910.0FalseNoneNoneFalseNoneFalse5043.90
260142381144NoneV-6 Item No 5.18.2Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A SP ---- etc., complete with all leadEach963.81963.8110.0FalseNoneNoneFalseNoneFalse9638.10
260142481144NoneV-6 Item No 5.18.3Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A SP ---- etc., complete with all leadEach985.68985.6810.0FalseNoneNoneFalseNoneFalse9856.80
260142581144NoneV-6 Item No 5.18.4Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A DP ---- etc., complete with all leadEach898.18898.1810.0FalseNoneNoneFalseNoneFalse8981.80
260142681144NoneV-6 Item No 5.18.5Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP ---- etc., complete with all leadEach1288.321288.3210.0FalseNoneNoneFalseNoneFalse12883.20
260142781144NoneV-6 Item No 5.18.6Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A DP ---- etc., complete with all leadEach1339.371339.3710.0FalseNoneNoneFalseNoneFalse13393.70
260142881144NoneV-6 Item No 5.18.7Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A TPN ---- etc., complete with all leadEach2086.842086.8410.0FalseNoneNoneFalseNoneFalse20868.40
260142981144NoneV-6 Item No 5.18.8Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A TPN ---- etc., complete with all leadEach3699.673699.6710.0FalseNoneNoneFalseNoneFalse36996.70
260143081144NoneV-6 Item No 5.18.9Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPN ---- etc., complete with all leadEach3753.153753.1510.0FalseNoneNoneFalseNoneFalse37531.50
260143181144NoneV-6 Item No 5.19.1Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.I - Single Door 4 Way SP & N ---- etc., complete with all leadEach1508.311508.314.0FalseNoneNoneFalseNoneFalse6033.240
260143281144NoneV-6 Item No 5.19.2Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.I - Single Door 6 Way SP & N ---- etc., complete with all leadEach1441.461441.464.0FalseNoneNoneFalseNoneFalse5765.840
260143381144NoneV-6 Item No 5.19.3Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.I - Single Door 8 Way SP & N ---- etc., complete with all leadEach1813.371813.374.0FalseNoneNoneFalseNoneFalse7253.480
260143481144NoneV-6 Item No 5.19.4Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.I - Single Door 12 Way SP & N ---- etc., complete with all leadEach2264.292264.294.0FalseNoneNoneFalseNoneFalse9057.160
260143581144NoneV-6 Item No 5.19.5Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.I - Single Door 16 Way SP & N ---- etc., complete with all leadEach3563.553563.554.0FalseNoneNoneFalseNoneFalse14254.20
260143681144NoneV-6 Item No 5.46.1Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA. 16 - 32 A SP ---- etc., complete with all leadEach255.23255.234.0FalseNoneNoneFalseNoneFalse1020.920
260143781144NoneV-6 Item No 5.46.4Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA. 16 - 32 A TP ---- etc., complete with all leadEach974.75974.754.0FalseNoneNoneFalseNoneFalse3899.00
260143881144NoneV-6 Item No 5.32Supplying and fixing digital frequency meter with latest micro controller technology, ultra bright 4 digit LED display, from 30-500V AC and optional or relay output for high/low frequency and wiring complete ---- etc., complete with all leadEach1185.011185.014.0FalseNoneNoneFalseNoneFalse4740.040
260143981144NoneV-6 Item No 11.3.1Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2' - 9/10 W ---- etc., complete with all leadEach669.68669.6810.0FalseNoneNoneFalseNoneFalse6696.80
260144081144NoneV-6 Item No 11.3.2Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 W ---- etc., complete with all leadEach838.62838.6210.0FalseNoneNoneFalseNoneFalse8386.20
260144181144NoneV-6 Item No 6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.48" Sweep (1200 mm) Regular model ---- etc., complete with all leadEach3626.753626.7510.0FalseNoneNoneFalseNoneFalse36267.50
260144281144NoneV-6 Item No 13.13Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete with all leadEach859.28859.285.0FalseNoneNoneFalseNoneFalse4296.40
260144381144NoneV-6 Item No 13.19Fixing all types and all capacities of 1'x4' / 2'x2' LED Light fittings indoor on the wall / ceiling / rafters / girders with necessary supporting frame, using 2310.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. ---- etc., complete with all leadEach595.54595.5425.0FalseNoneNoneFalseNoneFalse14888.50
260144481144NoneV-2 Item No 19.22.2Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction of Engineer-in-charge25 mm and up to 40 mm ---- etc., complete with all leadSqm90.8390.8378.311FalseNoneNoneFalseNoneFalse7112.988130
260144581144NoneV-2 Item No 19.22.2Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction of Engineer-in-charge25 mm and up to 40 mm ---- etc., complete with all leadSqm90.8390.83243.414FalseNoneNoneFalseNoneFalse22109.293620
260144681144NoneV-2 Item No 15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. ---- etc., complete with all leadSqm1002.911002.9178.311FalseNoneNoneFalseNoneFalse78538.885010
260144781144NoneV-2 Item No 2.4.1Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum9433.59433.53.0FalseNoneNoneFalseNoneFalse28300.50
260144881144NoneV-2 Item No 20.93Cleaning Quadrangle chajjas including removing of dirt dust etc., using suitrable soap powder , coconut broomstick, squeezers / wipers/ rubber brushes, coir brushes, plastric brushjes, mugs, booster pumps with portable arrangement, hose pipe etc., compl ---- etc., complete with all leadSqm18.4118.41120.15FalseNoneNoneFalseNoneFalse2211.96150
260144981144NoneV-2 Item No 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. ---- etc., complete with all leadSqm1091.291091.2978.311FalseNoneNoneFalseNoneFalse85460.011190
260145081144NoneV-2 Item No 8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm313.02313.02309.414FalseNoneNoneFalseNoneFalse96852.770280
260145181144NoneV-2 Item No 9.38Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete with all leadSqm1708.751708.75309.414FalseNoneNoneFalseNoneFalse528711.17250
260145281144NoneV-2 Item No 8.57Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all leadSqm15.9515.95402.59FalseNoneNoneFalseNoneFalse6421.31050
260145381144NoneV-2 Item No 8.63Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: One coats on old work as per specifications and as per directions of Engineer in charge. ---- etc., complete with all leadSqm100.65100.65435.592FalseNoneNoneFalseNoneFalse43842.33480
260145481144NoneV-2 Item No 14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid ---- etc., complete with all leadEach7337.097337.096.0FalseNoneNoneFalseNoneFalse44022.540
260145581144NoneV-2 Item No 14.1.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests ---- etc., complete with all leadEach5995.375995.375.0FalseNoneNoneFalseNoneFalse29976.850
260145681144NoneV-2 Item No 14.7.8Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow including operated levers ---- etc., complete with all leadEach5048.925048.9211.0FalseNoneNoneFalseNoneFalse55538.120
260145781144NoneV-2 Item No 14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer in-charge. ---- etc., complete with all leadEach994.31994.3111.0FalseNoneNoneFalseNoneFalse10937.410
260145881144NoneV-2 Item No 14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. ---- etc., complete with all leadEach6827.656827.656.0FalseNoneNoneFalseNoneFalse40965.90
260145981144NoneV-2 Item No 14.29Providing and fixing 100 mm sand cast Iron grating for gully trap. ---- etc., complete with all leadEach57.6957.6911.0FalseNoneNoneFalseNoneFalse634.590
260146081144None18-19 SR Item No 12.113.2Providing and fixing Cl Nahani trap of approved make conforming to lSI specifications and construction of Cistern in M-15 as per directions (Rate is inclusive of cost of materials and fixtures and conveyance of materials to work spot).12.5mmx75mm ---- etc., complete with all leadEach251.64251.646.0FalseNoneNoneFalseNoneFalse1509.840
260146181144NoneV-2 Item No 14.36.2Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 g ---- etc., complete with all leadEach114.16114.166.0FalseNoneNoneFalseNoneFalse684.960
260146281144NoneV-2 Item No 13.25Providing and fixing PTMT swivelling shower, 15 mm nominal bore, weighing not less than 40 gms ---- etc., complete with all leadNo179.22179.226.0FalseNoneNoneFalseNoneFalse1075.320
260146381144NoneV-5 Item No 10.1.7Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc.complete for:PVC pipes 110mm dia., 6 kg/sqcm & class 3 ---- etc., complete with all leadm504.52504.5225.0FalseNoneNoneFalseNoneFalse12613.00
260146481144NoneV-5 Item No 10.1.8Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc.complete for:PVC pipes 140mm dia., 6 kg/sqcm & class 3 ---- etc., complete with all leadm716.89716.8915.0FalseNoneNoneFalseNoneFalse10753.350
260146581144NoneV-2 Item No 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.15 mm dia ---- etc., complete with all leadm379.31379.3135.0FalseNoneNoneFalseNoneFalse13275.850
260146681144NoneV-2 Item No 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm dia ---- etc., complete with all leadm465.24465.2430.0FalseNoneNoneFalseNoneFalse13957.20
260146781144NoneV-2 Item No 13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.25 mm dia ---- etc., complete with all leadm585.54585.5430.0FalseNoneNoneFalseNoneFalse17566.20
260146881144NoneV-2 Item No 13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32mm dia ---- etc., complete with all leadm683.74683.7430.0FalseNoneNoneFalseNoneFalse20512.20
260146981144NoneV-3 Item No 2.4 (A)Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness..By Manual MeansIn area of light jungle ---- etc., complete with all leadSqm1363.671363.670.8FalseNoneNoneFalseNoneFalse1090.9360
260147081144NoneV-1 Item No 1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- etc., complete with all leadCum115.46115.4624.0FalseNoneNoneFalseNoneFalse2771.040
260147181144NoneV-1 Item No 1.15.3Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work .Depth exceeding 3m, but not exceeding 4.5m ---- etc., complete with all leadCum562.73562.73131.46FalseNoneNoneFalseNoneFalse73976.48580
260147281144NoneV-1 Item No 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum12475.4712475.4736.9FalseNoneNoneFalseNoneFalse460344.8430
260147381144NoneV-1 Item No 2.11 (a)Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. for Building ---- etc., complete with all leadTonne108726.03108726.034.509FalseNoneNoneFalseNoneFalse490245.669270
260147481144NoneV-2 Item No 15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. ---- etc., complete with all leadSqm992.98992.98112.98FalseNoneNoneFalseNoneFalse112186.88040
260147581144NoneV-2 Item No 8.12Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineerin-Charge. ---- etc., complete with all leadKg77.7877.7835.0FalseNoneNoneFalseNoneFalse2722.30
260147681144NoneV-2 Item No 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications ---- etc., complete with all leadSqm1592.171592.170.9FalseNoneNoneFalseNoneFalse1432.9530
260147781144NoneV-2 Item No 8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm450.91450.9158.38FalseNoneNoneFalseNoneFalse26324.12580
260147881144NoneV-2 Item No 8.3.1Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge ---- etc., complete with all leadSqm430.25430.2588.22FalseNoneNoneFalseNoneFalse37956.6550
260147981144NoneV-2 Item No 8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm211.47211.4758.38FalseNoneNoneFalseNoneFalse12345.61860
260148081144NoneItem No XXXVIIIProviding and fixing C. I Manhole covers 24" x 24" ---- etc., complete with all leadNo3040.933040.932.0FalseNoneNoneFalseNoneFalse6081.860
260148181144NoneV-2 Item No 11.16.3Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Electric resistance or induction butt welded tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all leadKg148.27148.2722.5FalseNoneNoneFalseNoneFalse3336.0750
260148281144NoneV-2 Item No 11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all leadKg686.7686.731.2FalseNoneNoneFalseNoneFalse21425.040
260148381144NoneV-5 Item No 10.1.5Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. PVC pipes 75mm dia., 6 kg/sqcm & class 3 ---- etc., complete with all leadm267.38267.38150.0FalseNoneNoneFalseNoneFalse40107.00
260148481144NoneV-2 Item No 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15mm dia ---- etc., complete with all leadm375.55375.5575.0FalseNoneNoneFalseNoneFalse28166.250
260148581144NoneV-2 Item No 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20mm dia ---- etc., complete with all leadm460.63460.6350.0FalseNoneNoneFalseNoneFalse23031.50
260148681144NoneV-2 Item No 13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25mm dia ---- etc., complete with all leadm579.74579.74100.0FalseNoneNoneFalseNoneFalse57974.00
260148781144NoneV-2 Item No 13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32mm dia ---- etc., complete with all leadm676.97676.97200.0FalseNoneNoneFalseNoneFalse135394.00
260148881144NoneV-2 Item No 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. ---- etc., complete with all leadl10.9310.934000.0FalseNoneNoneFalseNoneFalse43720.00
260148981144NoneV-5 Item No 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. ---- etc., complete with all leadNo6628.796628.7915.0FalseNoneNoneFalseNoneFalse99431.850
260149081144None160BAR SCREEN CHAMBER: MSFRP Bar Screen chamber rectangular tank,made up of Mild steel coated with FRP lining,Bar Screen Chamber Diemesion:1000x1000x1000 Length :1000 mm,Width :1000 mm,Height :1000 mm,Mild steel sheet Thickness: 3mm,FRP Lining ,Internal Thickness : 2mm,External Thcness: 2mm,inlet nozzelDia :4 inch,outLetnozzel Dia: 4 Bar Screen Size : 10mm,screen MOC : Mild Steel,Screen coating : Epoxy,Make : Orionwater. ---- etc., complete with all leadSet53100.053100.01.0FalseNoneNoneFalseNoneFalse53100.00
260149181144None161RAW SEWAGE TRANSFER PUMP Raw Sewage transfer pump capable of handling,sewage transfer from collection tank to RBC STP,maximum solid handling size upto 50 mm,Type : Centrifugal monoblock,Impeller :open,motor HP:1,RPM:2700,Flow Rate:2 m3/hr,Head:10,Moc : Cl,solid Particle Size Handling: 7 mm A).Valve : Suction : 2 nos,Delivery : 2 nos,Size :50 mm,Moc : B).Type : Ball /Butterfly, Non Return Valve, Delivery : 2 nos, Size :50 mm, Moc : Make : Kriloskar / CRI, Pump (1 w + 1S) 2nos of pump = 1 set. ---- etc., complete with all leadSet59000.059000.01.0FalseNoneNoneFalseNoneFalse59000.00
260149281144None162STP Rectamgular Tank Size and dimension:Width : 1500 mm, Over Height including Top Cover : 3000 mm, Length :6100 mm, MOC of rectangular Tank : Mild Steel, Shell Thickness: 5 mm FRP lining, Internal Liniing : 3 mm, External Lining : 3 mm, Pipe inlet Dia: 80 mm, Pipe Outlet Dia: 80 mm, Drain Header pipe Dia: 80 mm ---- etc., complete with all leadSet1046660.01046660.01.0FalseNoneNoneFalseNoneFalse1046660.00
260149381144None163Primary clarifier : Type : Lamella, No of Plates: 10, Lamella plate MOC: FRP, Lemella Plate Thickness: 2 mm ---- etc., complete with all leadSet457840.0457840.01.0FalseNoneNoneFalseNoneFalse457840.00
260149481144None164Secondary clarifier: Type : Lamella, No of Plates: 19, Lamella plate MOC: FRP, Lemella Plate Thickness: 3 mm ---- etc., complete with all leadSet450760.0450760.01.0FalseNoneNoneFalseNoneFalse450760.00
260149581144None165ROTOR: No of Rotors: 2, Moc: FRP, Diameter of Rotor : 1000mm, Connected with , Shaft : EN 90 Rod, Driven by : pillar Block, No of pillar block: 4 ---- etc., complete with all leadSet488520.0488520.01.0FalseNoneNoneFalseNoneFalse488520.00
260149681144None166Bio Zone (Rotor Placement Boat) No. of Biozone : 1 No, No. of Partisian inside Bio-zone : 4 Nos, MOC : MSFRP, Boat curvature Diameter : 1800mm, Bio Zone supporting with 150mm, Beam 2 Nos & 4 Nos. Legs., Boat Size:3350 mm ---- etc., complete with all leadSet436600.0436600.01.0FalseNoneNoneFalseNoneFalse436600.00
260149781144None167Gear Box : Type: Helical, No of Gear Box: 1 no, Make : Bonfigoli (Germany), Gear Box Motor HP: 1, Gear Box motor Make : Seimens. ---- etc., complete with all leadSet112100.0112100.01.0FalseNoneNoneFalseNoneFalse112100.00
260149881144None168Internal Piping & Base Works : 1) Inter connecting pipe works with FRP lining inside process tank, Recirculion& drain system. 2)Base Plate works for Gear box arrangement,Rotor Fixing arrangement,Biozone leg placement arrangement. RBC STP Make : Orionwater ---- etc., complete with all leadSet68440.068440.01.0FalseNoneNoneFalseNoneFalse68440.00
260149981144None169FILTER FEED PUMP: Filter feed pump capable of handling to transfer clarifed to filtration plant maximum solid handling size upto 20 mm, Type : Centrifugal monoblock, Impeller : Closed motor HP:3, RPM:1700, Flow Rate: 6m3/hr, Head:30, Moc : solid Particle Size Handling: 50mm Valve , Suction : 2 nos, Delivery : 2 nos, Size :50 mm, Moc : Type : Ball /Butterfly, Non Return Valve, Delivery : 2 nos, Size :50 mm, Moc : , Make : Kriloskar / CRI, Pump (1 w + 1S) 2nos of pump = 1 set ---- etc., complete with all leadSet29500.029500.01.0FalseNoneNoneFalseNoneFalse29500.00
260150081144None170SAND FILTER : Diameter: 600 mm, Height On Straight: 1900 mm, Shell hickness: 6mm, Dish end Thickness: 8mm, Frontal Pipeline:, MOC: Mild Steel, External Coating : Red Oxide and Enamel paint, Internal Coating: Black Bitumus, Fiter Media: Fine Sand, Gravel sand, pebbles,silex, Media in KG: 450, Media Depth : 915 mm, Type : Cylindrical, Vertical. ---- etc., complete with all leadSet159300.0159300.01.0FalseNoneNoneFalseNoneFalse159300.00
260150181144None171ACTIVATED CARBON FILTER: Diameter: 600 mm,Height On Straight: 1900 mm, Shell hickness: 6mm,Dish end Thickness: 8mm Frontal Pipeline: MOC: Mild Steel,External Coating :Red Oxide and Enamel paint,Internal Coating: Black Bitumus,Fiter Media: Activated Carbon Media in KG: 150,Media Depth : 1000 mm,Type : Cylindrical. ---- etc., complete with all leadSet159300.0159300.01.0FalseNoneNoneFalseNoneFalse159300.00
260150281144None172CHLORINE DOSING SYSTEM, Pump type : ElectonicDiaphram Capacity : 0- 2LPH, Nominal Back pressure : 6 KG/CM2, Maximum Back pressure: 8 KG/CM2 KW: 0.24 watt, Tank Capacity : 100 Liters, MOC: PP, Make : LMI Asia ---- etc., complete with all leadSet33040.033040.01.0FalseNoneNoneFalseNoneFalse33040.00
260150381144None173INTERCONNECTING PIPE WORK All necessary pipe work from Bar Screen chamber to collection tank, collection tank to Raw sewage transfer pump, Raw sewage transfer pump to RBC STP, RBC STP to Filter feed pump, Filter feed pump to Filtration plant and filtration plant to treated water tank The scope shall be PVC pipes with all necessary valves, NRV , Float switch and drain Header. ---- etc., complete with all leadSet147500.0147500.01.0FalseNoneNoneFalseNoneFalse147500.00
260150481144None174CONTROL PANEL: Installation, testing and commissioning of Electrical Panel suitable for 415V, 3 phase, 4 wire, 50Hz distribution system. The panel shall be Wall Mounting type, sheet metal enclosed, flush front with aluminium busbars, separate earth bus shall be provided throughout the length of the panel. The incoming and the outgoing feeder breakers, switch fuse units, change over switches, indicating lamps, meters etc. shall be accommodated in a modular multi-tier arrangement. The painting shall be done in conformity with IS code. Adequate size cable alley shall be provided all around the panel and at the back for easy bending and terminations. The outgoing feeders inside the panel shall be connected through solid busbars. Busbars shall be provided with PVC heat shrinkable sleeves or heat resistant insulated paint. The panels shall be suitable for cable entry from top / bottom. ---- etc., complete with all leadSet206500.0206500.01.0FalseNoneNoneFalseNoneFalse206500.00
260150581144None175FREIGHT LOADING AND UNLOADING : All the equipment shall be loaded ,transported and unloaded at site. Including the necessary Cranes required to erect and position the system ---- etc., complete with all leadSet88500.088500.01.0FalseNoneNoneFalseNoneFalse88500.00
260150681144None176INSTALLATION, ERECTION, COMMISSIONING, TESTING AND HANDING OVER AT SITE. From the Inlet of the Bar Screen chamber to the output of Caron filter ---- etc., complete with all leadSet118000.0118000.01.0FalseNoneNoneFalseNoneFalse118000.00
260150781144NoneV-6 Item No 32.091.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 3.5 core 35 sqmm ---- etc., complete with all leadKm187246.95187246.950.1FalseNoneNoneFalseNoneFalse18724.6950
260150881144NoneSR 21-22 V-6 Item No BSR-31.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff. 35 sqmm to 95 sqmm ---- etc., complete with all leadKm37846.3437846.340.1FalseNoneNoneFalseNoneFalse3784.6340
260150981144None19-20 SR Item No 6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only). 32mm dia ---- etc., complete with all leadEach142.2142.26.0FalseNoneNoneFalseNoneFalse853.20
260151081144NoneSR 21-22 V-6 Item No BSR 49.05Supplying and fixing of class A (medium duty) GI pipe of wall thick ness not less than 3.25mm on pole/wall/drain crossing with necessary clamping arrangements for UG cable of 1.1 KV class. 50mm ---- etc., complete with all leadm465.49465.4910.0FalseNoneNoneFalseNoneFalse4654.90
260151181144None19-20 SR Item No 6.17.8Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 35 sqmm Long Barrel ---- etc., complete with all leadEach38.8938.894.0FalseNoneNoneFalseNoneFalse155.560
260151281144NoneSR 21-22 V-6 Item No BSR-29.03Earth work excavation for cable trench of 0.5 to 0.75 M. Width and Depth upto 1 M including trial pits, depositing on bank upto a lead of 50 M,Supplying and Displaying necessary Danger Boards and Lighting, Using sightRails and Sign Boards at every 100 M wherever necessary as directed. In soil (hard) ---- etc., complete with all leadCum472.79472.7920.0FalseNoneNoneFalseNoneFalse9455.80
260151381144NoneV-6 Item No 12.57Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc using 40mm dia 2.9mm thick 2.5 M long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm alround with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. ---- etc., complete with all leadNo5172.745172.742.0FalseNoneNoneFalseNoneFalse10345.480
260151481144None19-20 SR Item No 6.18.3Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.,(75/23) 8 SWG-GI Wire ---- etc., complete with all leadm23.0923.0950.0FalseNoneNoneFalseNoneFalse1154.50
260151581144NoneV-6 Item No 12.58Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip ---- etc., complete with all leadm99.6699.6625.0FalseNoneNoneFalseNoneFalse2491.50
17079850450000NoneNoneBuildingsConstruction of STP works to CHC at Ankali in Chikkodi taluk, Belagavi District.(Slice-2)2999806.44
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
260151681145NoneV-6 Item No 32.091.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 3.5 core 35 sqmm ---- etc., complete with all leadKm190882.81190882.810.1FalseNoneNoneFalseNoneFalse19088.2810
260151781145NoneSR 21-22 V-6 Item No BSR-31.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff. 35 sqmm to 95 sqmm ---- etc., complete with all leadKm38581.2238581.220.1FalseNoneNoneFalseNoneFalse3858.1220
260151881145None19-20 SR Item No 6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only). 32mm dia ---- etc., complete with all leadEach144.96144.966.0FalseNoneNoneFalseNoneFalse869.760
260151981145NoneSR 21-22 V-6 Item No BSR 49.05Supplying and fixing of class A (medium duty) GI pipe of wall thick ness not less than 3.25mm on pole/wall/drain crossing with necessary clamping arrangements for UG cable of 1.1 KV class. 50mm ---- etc., complete with all leadm474.53474.538.0FalseNoneNoneFalseNoneFalse3796.240
260152081145None19-20 SR Item No 6.17.8Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 35 sqmm Long Barrel ---- etc., complete with all leadEach39.6439.644.0FalseNoneNoneFalseNoneFalse158.560
260152181145NoneSR 21-22 V-6 Item No BSR-29.03Earth work excavation for cable trench of 0.5 to 0.75 M. Width and Depth upto 1 M including trial pits, depositing on bank upto a lead of 50 M,Supplying and Displaying necessary Danger Boards and Lighting, Using sightRails and Sign Boards at every 100 M wherever necessary as directed. In soil (hard) ---- etc., complete with all leadCum481.97481.9710.0FalseNoneNoneFalseNoneFalse4819.70
260152281145NoneV-6 Item No 12.57Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc using 40mm dia 2.9mm thick 2.5 M long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm alround with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. ---- etc., complete with all leadNo5273.185273.181.0FalseNoneNoneFalseNoneFalse5273.180
260152381145None19-20 SR Item No 6.18.3Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.,(75/23) 8 SWG-GI Wire ---- etc., complete with all leadm23.5423.5420.0FalseNoneNoneFalseNoneFalse470.80
260152481145NoneV-6 Item No 12.58Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip ---- etc., complete with all leadm101.59101.5920.0FalseNoneNoneFalseNoneFalse2031.80
260152581145None010BAR SCREEN CHAMBER: MSFRP Bar Screen chamber rectangular tank,made up of Mild steel coated with FRP lining,Bar Screen Chamber Diemesion:1000x1000x1000 Length :1000 mm,Width :1000 mm,Height :1000 mm,Mild steel sheet Thickness: 3mm,FRP Lining ,Internal Thickness : 2mm,External Thcness: 2mm,inlet nozzelDia :4 inch,outLetnozzel Dia: 4 Bar Screen Size : 10mm,screen MOC : Mild Steel,Screen coating : Epoxy,Make : Orionwater. ---- etc., complete with all leadSet53100.053100.01.0FalseNoneNoneFalseNoneFalse53100.00
260152681145None011RAW SEWAGE TRANSFER PUMP Raw Sewage transfer pump capable of handling,sewage transfer from collection tank to RBC STP,maximum solid handling size upto 50 mm,Type : Centrifugal monoblock,Impeller :open,motor HP:1,RPM:2700,Flow Rate:1 m3/hr,Head:10,Moc : Cl,solid Particle Size Handling: 7 mm A).Valve : Suction : 2 nos,Delivery : 2 nos,Size :50 mm,Moc : B).Type : Ball /Butterfly, Non Return Valve, Delivery : 2 nos, Size :50 mm, Moc : Make : Kriloskar / CRI, Pump (1 w + 1S) 2nos of pump = 1 set. ---- etc., complete with all leadSet59000.059000.01.0FalseNoneNoneFalseNoneFalse59000.00
260152781145None012STP Rectamgular Tank Size and dimension:Width : 1500 mm, Over Height including Top Cover : 3000 mm, Length :5350 mm, MOC of rectangular Tank : Mild Steel, Shell Thickness: 5 mm FRP lining, Internal Liniing : 3 mm, External Lining : 3 mm, Pipe inlet Dia: 80 mm, Pipe Outlet Dia: 80 mm, Drain Header pipe Dia: 80 mm ---- etc., complete with all leadSet888540.0888540.01.0FalseNoneNoneFalseNoneFalse888540.00
260152881145None013Primary clarifier : Type : Lamella, No of Plates: 10, Lamella plate MOC: FRP, Lemella Plate Thickness: 2 mm ---- etc., complete with all leadSet398840.0398840.01.0FalseNoneNoneFalseNoneFalse398840.00
260152981145None014Secondary clarifier: Type : Lamella, No of Plates: 19, Lamella plate MOC: FRP, Lemella Plate Thickness: 3 mm ---- etc., complete with all leadSet391760.0391760.01.0FalseNoneNoneFalseNoneFalse391760.00
260153081145None015ROTOR: No of Rotors: 2, Moc: FRP, Diameter of Rotor : 1000mm, Connected with , Shaft : EN 90 Rod, Driven by : pillar Block, No of pillar block: 4 ---- etc., complete with all leadSet252520.0252520.01.0FalseNoneNoneFalseNoneFalse252520.00
260153181145None016Gear Box : Type: Helical, No of Gear Box: 1 no, Make : Bonfigoli (Germany), Gear Box Motor HP: 1, Gear Box motor Make : Seimens. ---- etc., complete with all leadSet112100.0112100.01.0FalseNoneNoneFalseNoneFalse112100.00
260153281145None017Internal Piping & Base Works : 1) Inter connecting pipe works with FRP lining inside process tank, Recirculion& drain system. 2)Base Plate works for Gear box arrangement,Rotor Fixing arrangement,Biozone leg placement arrangement. RBC STP Make : Orionwater ---- etc., complete with all leadSet68440.068440.01.0FalseNoneNoneFalseNoneFalse68440.00
260153381145None018FILTER FEED PUMP: Filter feed pump capable of handling to transfer clarifed to filtration plant maximum solid handling size upto 20 mm, Type : Centrifugal monoblock, Impeller : Closed motor HP:3, RPM:1700, Flow Rate: 6m3/hr, Head:30, Moc : solid Particle Size Handling: 50mm Valve , Suction : 2 nos, Delivery : 2 nos, Size :50 mm, Moc : Type : Ball /Butterfly, Non Return Valve, Delivery : 2 nos, Size :50 mm, Moc : , Make : Kriloskar / CRI, Pump (1 w + 1S) 2nos of pump = 1 set ---- etc., complete with all leadSet29500.029500.01.0FalseNoneNoneFalseNoneFalse29500.00
260153481145None019SAND FILTER : Diameter: 600 mm, Height On Straight: 1900 mm, Shell hickness: 6mm, Dish end Thickness: 8mm, Frontal Pipeline:, MOC: Mild Steel, External Coating : Red Oxide and Enamel paint, Internal Coating: Black Bitumus, Fiter Media: Fine Sand, Gravel sand, pebbles,silex, Media in KG: 450, Media Depth : 915 mm, Type : Cylindrical, Vertical. ---- etc., complete with all leadSet123900.0123900.01.0FalseNoneNoneFalseNoneFalse123900.00
260153581145None020ACTIVATED CARBON FILTER: Diameter: 600 mm,Height On Straight: 1900 mm, Shell hickness: 6mm,Dish end Thickness: 8mm Frontal Pipeline: MOC: Mild Steel,External Coating :Red Oxide and Enamel paint,Internal Coating: Black Bitumus,Fiter Media: Activated Carbon Media in KG: 150,Media Depth : 1000 mm,Type : Cylindrical. ---- etc., complete with all leadSet123900.0123900.01.0FalseNoneNoneFalseNoneFalse123900.00
260153681145None021CHLORINE DOSING SYSTEM, Pump type : ElectonicDiaphram Capacity : 0- 2LPH, Nominal Back pressure : 6 KG/CM2, Maximum Back pressure: 8 KG/CM2 KW: 0.24 watt, Tank Capacity : 100 Liters, MOC: PP, Make : LMI Asia ---- etc., complete with all leadSet33040.033040.01.0FalseNoneNoneFalseNoneFalse33040.00
260153781145None022INTERCONNECTING PIPE WORK All necessary pipe work from Bar Screen chamber to collection tank, collection tank to Raw sewage transfer pump, Raw sewage transfer pump to RBC STP, RBC STP to Filter feed pump, Filter feed pump to Filtration plant and filtration plant to treated water tank The scope shall be PVC pipes with all necessary valves, NRV , Float switch and drain Header. ---- etc., complete with all leadSet118000.0118000.01.0FalseNoneNoneFalseNoneFalse118000.00
260153881145None023CONTROL PANEL: Installation, testing and commissioning of Electrical Panel suitable for 415V, 3 phase, 4 wire, 50Hz distribution system. The panel shall be Wall Mounting type, sheet metal enclosed, flush front with aluminium busbars, separate earth bus shall be provided throughout the length of the panel. The incoming and the outgoing feeder breakers, switch fuse units, change over switches, indicating lamps, meters etc. shall be accommodated in a modular multi-tier arrangement. The painting shall be done in conformity with IS code. Adequate size cable alley shall be provided all around the panel and at the back for easy bending and terminations. The outgoing feeders inside the panel shall be connected through solid busbars. Busbars shall be provided with PVC heat shrinkable sleeves or heat resistant insulated paint. The panels shall be suitable for cable entry from top / bottom. ---- etc., complete with all leadSet147500.0147500.01.0FalseNoneNoneFalseNoneFalse147500.00
260153981145None024FREIGHT LOADING AND UNLOADING : All the equipment shall be loaded ,transported and unloaded at site. Including the necessary Cranes required to erect and position the system ---- etc., complete with all leadSet70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
260154081145None025INSTALLATION, ERECTION, COMMISSIONING, TESTING AND HANDING OVER AT SITE. From the Inlet of the Bar Screen chamber to the output of Caron filter ---- etc., complete with all leadSet88500.088500.01.0FalseNoneNoneFalseNoneFalse88500.00
17079850450001NoneNoneBuildingsUp-gradation of infrastructure facilities to the TLH at Ramdurga in Belagavi District.(Slice-3)9296583.56
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
260154181146NoneCSR2023-24 V-1 Page No 37 Item No 1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- etc., complete with all leadCum126.37126.37207.5FalseNoneNoneFalseNoneFalse26221.7750
260154281146NoneCSR2023-24 V-1 Page No 34 Item No 1.9Filling available excavated earth (excluding rock)in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm indepth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete with all leadCum329.57329.57488.0FalseNoneNoneFalseNoneFalse160830.160
260154381146NoneCSR2023-24 V-2 Page No 14 Item No 6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. ---- etc., complete with all leadCum9873.599873.5925.0FalseNoneNoneFalseNoneFalse246839.750
260154481146NoneCSR2023-24 V-1 Page No 15 Item No 2.1.4Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators,including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum7702.867702.8663.0111FalseNoneNoneFalseNoneFalse485365.6817460
260154581146NoneCSR2023-24 V-2 Page No 104 Item No 12.53Providing & fixing 30mm thick factory made rigid foam Panelled Door Shutters made from M.S. tube of 19 gauge thickness, size 19x19mm for stiles and 15x15mm for top & bottom rails, covered with heat moulded PVC C channel of 5mm thick sheet & 30 x 50mm wide to form stiles & 5mm thick & 75mm wide PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet fitted in the M.S. Frame, Sealed to the stiles & rails with 5x30mm PVC sheet beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 No of 75 mm Aluminium hinges. ---- etc., complete with all leadSqm1967.531967.5315.75FalseNoneNoneFalseNoneFalse30988.59750
260154681146NoneCSR2023-24 V-2 Page No 105 Item No 12.57.5Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-do- 35 mm thick one side teak and one side commercial ---- etc., complete with all leadSqm4828.384828.3820.16FalseNoneNoneFalseNoneFalse97340.14080
260154781146NoneCSR2023-24 V-2 Page No 77 Item No 11.5.1Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. ---- etc., complete with all leadSqm5548.245548.243.96FalseNoneNoneFalseNoneFalse21971.03040
260154881146NoneCSR2023-24 V-2 Page No 197 Item No 20.3.1Float glass panes of nominal thickness 4 mm (weight not less than 10kg/m²) ---- etc., complete with all leadSqm1803.981803.9822.0FalseNoneNoneFalseNoneFalse39687.560
260154981146NoneCSR2023-24 V-2 Page No 105 Item No 12.6Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete with all leadNo1303.421303.4210.0FalseNoneNoneFalseNoneFalse13034.20
260155081146NoneCSR2023-24 V-2 Page No 105 Item No 12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on thebody, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. ---- etc., complete with all leadNo1380.241380.243.0FalseNoneNoneFalseNoneFalse4140.720
260155181146NoneCSR2023-24 V-2 Page No 207 Item No 20.96Cleaning of office floors, toilet floors, corridors, lobbies, partitions, storage units, furnitures,electrical & electronic equipments, doors, windows, curtains, blinds etc., including cleaning of dust, etc., using suitable bombay broom stick, squezers ---- etc., complete with all leadSqm3.713.711600.0FalseNoneNoneFalseNoneFalse5936.00
260155281146NoneCSR2023-24 V-2 Page No 206 Item No 20.91External sweeping and terrace cleaning - Cleaning of outer periphery like roads footpaths curb stones terrace including removing grass dust etc., to the nearest garbage pit using suitable coconut broomstic,bombay broomstick, squezers /wipers /rubberbru ---- etc., complete with all leadSqm1.231.231800.0FalseNoneNoneFalseNoneFalse2214.00
260155381146NoneCSR2023-24 V-2 Page No 188 Item No 19.13.1Taking out doors, windows and clerestory window shutters (steel or wood) including stacking to the appropriate disposal area as per direction of Engineer-in-charge.Of area beyond 3 m² ---- etc., complete with all leadSqm116.46116.4635.0FalseNoneNoneFalseNoneFalse4076.10
260155481146NoneCSR2023-24 V-5 Page No 113 Item No 10.1.3Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 50mm dia., 6 kg/sqcm & class 5 ---- etc., complete with all leadm125.13125.13200.0FalseNoneNoneFalseNoneFalse25026.00
260155581146NoneCSR2023-24 V-5 Page No 113 Item No 10.1.5Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 75mm dia., 6 kg/sqcm & class 3 ---- etc., complete with all leadm272.58272.58210.0FalseNoneNoneFalseNoneFalse57241.80
260155681146NoneCSR2023-24 V-5 Page No 113 Item No 10.1.7Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 ---- etc., complete with all leadm509.23509.23372.33FalseNoneNoneFalseNoneFalse189601.60590
260155781146NoneCSR2023-24 V-5 Page No 113 Item No 10.1.8Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 140mm dia., 6 kg/sqcm & class 3 ---- etc., complete with all leadm723.58723.58524.0FalseNoneNoneFalseNoneFalse379155.920
260155881146NoneCSR2023-24 V-2 Page No 122 Item No 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15mm dia ---- etc., complete with all leadm382.85382.85115.0FalseNoneNoneFalseNoneFalse44027.750
260155981146NoneCSR2023-24 V-2 Page No 122 Item No 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20mm dia ---- etc., complete with all leadm469.58469.58180.0FalseNoneNoneFalseNoneFalse84524.40
260156081146NoneCSR2023-24 V-2 Page No 112 Item No 13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25mm dia ---- etc., complete with all leadm591.0591.0210.0FalseNoneNoneFalseNoneFalse124110.00
260156181146NoneCSR2023-24 V-2 Page No 136 Item No 14.29Providing and fixing 100 mm sand cast Iron grating for gully trap. ---- etc., complete with all leadEach58.2358.2310.0FalseNoneNoneFalseNoneFalse582.30
260156281146NoneCSR2023-24 V-2 Page No 131 Item No 14.1.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests ---- etc., complete with all leadEach6051.276051.275.0FalseNoneNoneFalseNoneFalse30256.350
260156381146NoneCSR2023-24 V-2 Page No 131 Item No 14.3Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : ---- etc., complete with all leadEach7430.287430.284.0FalseNoneNoneFalseNoneFalse29721.120
260156481146NoneCSR2023-24 V-2 Page No 132 Item No 14.7.5Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Angle back wash basin size 600 x 480 mm with single 15mm C.P. brass pillar tap ---- etc., complete with all leadEach3173.073173.075.0FalseNoneNoneFalseNoneFalse15865.350
260156581146NoneCSR2023-24 V-2 Page No 134 Item No 14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required :Size 600x450x200 mm ---- etc., complete with all leadEach6296.596296.595.0FalseNoneNoneFalseNoneFalse31482.950
260156681146NoneCSR2023-24 V-2 Page No A-33 Item No 496Rectangular shape 453x357 mm Mirror with Plastic moulded frame ---- etc., complete with all leadEach359.31359.315.0FalseNoneNoneFalseNoneFalse1796.550
260156781146NoneCSR2023-24 V-2 Page No 137 Item No 14.40.2Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. ---- etc., complete with all leadEach614.54614.546.0FalseNoneNoneFalseNoneFalse3687.240
260156881146NoneCSR2023-24 V-2 Page No 119 Item No 13.1513.15 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. ---- etc., complete with all leadNo898.27898.2712.0FalseNoneNoneFalseNoneFalse10779.240
260156981146NoneCSR2023-24 V-2 Page No 117 Item No 13.4.1Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :(25 mm nominal bore) ---- etc., complete with all leadNo680.21680.216.0FalseNoneNoneFalseNoneFalse4081.260
260157081146NoneCSR2023-24 V-2 Page No 117 Item No 13.4.2Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :(32 mm nominal bore) ---- etc., complete with all leadNo740.92740.924.0FalseNoneNoneFalseNoneFalse2963.680
260157181146NoneCSR2023-24 V-2 Page No 117 Item No 13.5.2Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :20 mm nominal bore ---- etc., complete with all leadNo389.04389.046.0FalseNoneNoneFalseNoneFalse2334.240
260157281146NoneCSR2023-24 V-2 Page No 119 Item No 13.12Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 ---- etc., complete with all leadNo786.76786.764.0FalseNoneNoneFalseNoneFalse3147.040
260157381146NoneCSR2023-24 V-1 Page No 5 Item No 1.1Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications ---- etc., complete with all leadCum198.24198.2495.0FalseNoneNoneFalseNoneFalse18832.80
260157481146NoneCSR2023-24 V-6 Page No 2 Item No 1.1.1Supplying heavy gauge PVC conduit pipe.......dia.......mm thick confirming to IS2509 with suitable size bends,junctionboxes,adhesivepaste etc,and fixing using inverted wood plugs incase of RCCceiling andRCC wall/stonestructure or rawl plugs incase of brick wallsandcement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.20 mm dia ---- etc., complete with all leadm85.4985.49100.0FalseNoneNoneFalseNoneFalse8549.00
260157581146NoneCSR2023-24 V-6 Page No 2 Item No 1.1.2Supplying heavy gauge PVC conduit pipe.......dia.......mm thick confirming to IS2509 with suitable size bends,junctionboxes,adhesivepaste etc,and fixing using inverted wood plugs incase of RCCceiling andRCC wall/stonestructure or rawl plugs incase of brick wallsandcement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.25 mm dia ---- etc., complete with all leadm96.3196.31120.0FalseNoneNoneFalseNoneFalse11557.20
260157681146NoneCSR2023-24 V-6 Page No 2 Item No 1.1.3SSupplying heavy gauge PVC conduit pipe.......dia.......mm thick confirming to IS2509 with suitable size bends,junctionboxes,adhesivepaste etc,and fixing using inverted wood plugs incase of RCCceiling andRCC wall/stonestructure or rawl plugs incase of brick wallsandcement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.32 mm dia ---- etc., complete with all leadm126.03126.03100.0FalseNoneNoneFalseNoneFalse12603.00
260157781146NoneCSR2023-24 V-6 Page No 2 Item No 1.3.1Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 20 mm dia ---- etc., complete with all leadm80.8580.85100.0FalseNoneNoneFalseNoneFalse8085.00
260157881146NoneCSR2023-24 V-6 Page No 2 Item No 1.3.2Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 25 mm dia ---- etc., complete with all leadm93.9393.93150.0FalseNoneNoneFalseNoneFalse14089.50
260157981146NoneCSR2023-24 V-6 Page No 2 Item No 1.3.3Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 32 mm dia ---- etc., complete with all leadm117.71117.71120.0FalseNoneNoneFalseNoneFalse14125.20
260158081146NoneCSR2023-24 V-6 Page No 2 Item No 1.4.1Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 75 x 75 x 65 mm ---- etc., complete with all leadEach126.03126.0320.0FalseNoneNoneFalseNoneFalse2520.60
260158181146NoneCSR2023-24 V-6 Page No 2 Item No 1.4.2Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.100 x 75 x 65 mm ---- etc., complete with all leadEach140.03140.0315.0FalseNoneNoneFalseNoneFalse2100.450
260158281146NoneCSR2023-24 V-6 Page No 2 Item No 1.5.1Supplying and fixing PVC/metal conduit Deep junction box 19/20mm deep junction box ---- etc., complete with all leadEach58.2658.2639.0FalseNoneNoneFalseNoneFalse2272.140
260158381146NoneCSR2023-24 V-6 Page No 3 Item No 1.5.2Supplying and fixing PVC/metal conduit Deep junction box 25mm deep junction box ---- etc., complete with all leadEach66.5866.5820.0FalseNoneNoneFalseNoneFalse1331.60
260158481146NoneCSR2023-24 V-6 Page No 4 Item No 1.11Supplying And Fixing "S" Hook made out of 14 mm dia M.S. Rod. ---- etc., complete with all leadEach61.8361.8315.0FalseNoneNoneFalseNoneFalse927.450
260158581146NoneCSR2023-24 V-6 Page No 4 Item No 1.12Supplying And Fixing M.S. Rafter Clamp Set made out of M.S. Flat & 14 mm M.S. rod ---- etc., complete with all leadEach190.24190.2415.0FalseNoneNoneFalseNoneFalse2853.60
260158681146NoneCSR2023-24 V-6 Page No 4 Item No 1.13Supplying And Fixing Metal Fan Box with Round Hook ---- etc., complete with all leadEach139.11139.1115.0FalseNoneNoneFalseNoneFalse2086.650
260158781146NoneCSR2023-24 V-6 Page No 5 Item No 2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm 2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet Short point upto 3 mts from tapping point to out let via switch ---- etc., complete with all leadPoint319.84319.8455.0FalseNoneNoneFalseNoneFalse17591.20
260158881146NoneCSR2023-24 V-6 Page No 5 Item No 2.2.2Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm 2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet Medium point above 3 mts upto 6mts from tapping point to outlet via switch ---- etc., complete with all leadPoint450.63450.6355.0FalseNoneNoneFalseNoneFalse24784.650
260158981146NoneCSR2023-24 V-6 Page No 5 Item No 2.2.3Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm 2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet Long point above 6 mts upto 10 mts from tapping point to outlet via switch ---- etc., complete with all leadPoint659.9659.940.0FalseNoneNoneFalseNoneFalse26396.00
260159081146NoneCSR2023-24 V-6 Page No 5 Item No 2.2.4Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm 2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet Two outlet in a row above 3mts upto 6 mts from tapping point to outlet via switches ---- etc., complete with all leadPoint804.95804.9530.0FalseNoneNoneFalseNoneFalse24148.50
260159181146NoneCSR2023-24 V-6 Page No 5 Item No 2.2.5Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm 2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet Three outlet in a row above 6 mts upto 10 mts from the tapping point to outlet via switches ---- etc., complete with all leadPoint1175.921175.9230.0FalseNoneNoneFalseNoneFalse35277.60
260159281146NoneCSR2023-24 V-6 Page No 5 Item No 2.3.1Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 1mm ---- etc., complete with all leadm22.5922.59500.0FalseNoneNoneFalseNoneFalse11295.00
260159381146NoneCSR2023-24 V-6 Page No 5 Item No 2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 1.5mm ---- etc., complete with all leadm30.9130.91600.0FalseNoneNoneFalseNoneFalse18546.00
260159481146NoneCSR2023-24 V-6 Page No 5 Item No 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 2.5mm ---- etc., complete with all leadm49.9449.94500.0FalseNoneNoneFalseNoneFalse24970.00
260159581146NoneCSR2023-24 V-6 Page No 5 Item No 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 4mm ---- etc., complete with all leadm74.9174.91200.0FalseNoneNoneFalseNoneFalse14982.00
260159681146NoneCSR2023-24 V-6 Page No 5 Item No 2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 6mm ---- etc., complete with all leadm109.39109.39200.0FalseNoneNoneFalseNoneFalse21878.00
260159781146NoneCSR2023-24 V-6 Page No 7 Item No 2.6.4Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 V as per IS-694:2010. 3C x 10 mm2 ---- etc., complete with all leadm491.06491.0690.0FalseNoneNoneFalseNoneFalse44195.40
260159881146NoneCSR2023-24 V-6 Page No 8 Item No 3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1 - 2Way ---- etc., complete with all leadEach164.08164.0845.0FalseNoneNoneFalseNoneFalse7383.60
260159981146NoneCSR2023-24 V-6 Page No 8 Item No 3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4 - 5Way ---- etc., complete with all leadEach210.45210.4575.0FalseNoneNoneFalseNoneFalse15783.750
260160081146NoneCSR2023-24 V-6 Page No 8 Item No 3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6 Way ---- etc., complete with all leadEach261.58261.5850.0FalseNoneNoneFalseNoneFalse13079.00
260160181146NoneCSR2023-24 V-6 Page No 8 Item No 3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way ---- etc., complete with all leadEach310.33310.3340.0FalseNoneNoneFalseNoneFalse12413.20
260160281146NoneCSR2023-24 V-6 Page No 8 Item No 3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10 / 12 Way ---- etc., complete with all leadEach379.29379.2940.0FalseNoneNoneFalseNoneFalse15171.60
260160381146NoneCSR2023-24 V-6 Page No 8 Item No 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required No of machine screws , bolts nuts etc,.complete on the existing metal box 1 to 2Module ---- etc., complete with all leadEach162.89162.8930.0FalseNoneNoneFalseNoneFalse4886.70
260160481146NoneCSR2023-24 V-6 Page No 8 Item No 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required No of machine screws , bolts nuts etc,.complete on the existing metal box 4 Module ---- etc., complete with all leadEach208.08208.0830.0FalseNoneNoneFalseNoneFalse6242.40
260160581146NoneCSR2023-24 V-6 Page No 8 Item No 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required No of machine screws , bolts nuts etc,.complete on the existing metal box 6 Module ---- etc., complete with all leadEach278.23278.2315.0FalseNoneNoneFalseNoneFalse4173.450
260160681146NoneCSR2023-24 V-6 Page No 8 Item No 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required No of machine screws , bolts nuts etc,.complete on the existing metal box 8 Module ---- etc., complete with all leadEach337.68337.6815.0FalseNoneNoneFalseNoneFalse5065.20
260160781146NoneCSR2023-24 V-6 Page No 8 Item No 3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required No of machine screws , bolts nuts etc,.complete on the existing metal box 10/12 Module ---- etc., complete with all leadEach409.02409.0215.0FalseNoneNoneFalseNoneFalse6135.30
260160881146NoneCSR2023-24 V-6 Page No 9 Item No 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6 amps one way switch ---- etc., complete with all leadEach121.28121.2830.0FalseNoneNoneFalseNoneFalse3638.40
260160981146NoneCSR2023-24 V-6 Page No 9 Item No 3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6 amps two way switch ---- etc., complete with all leadEach197.37197.3750.0FalseNoneNoneFalseNoneFalse9868.50
260161081146NoneCSR2023-24 V-6 Page No 9 Item No 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6 Amps 3 way sockets ---- etc., complete with all leadEach203.32203.3230.0FalseNoneNoneFalseNoneFalse6099.60
260161181146NoneCSR2023-24 V-6 Page No 9 Item No 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. stepped fan Regulator's ---- etc., complete with all leadEach424.47424.4715.0FalseNoneNoneFalseNoneFalse6367.050
260161281146NoneCSR2023-24 V-6 Page No 9 Item No 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16 Amps universal sockets ---- etc., complete with all leadEach280.6280.615.0FalseNoneNoneFalseNoneFalse4209.00
260161381146NoneCSR2023-24 V-6 Page No 9 Item No 3.6.7Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16 Amps one way Switch ---- etc., complete with all leadEach214.02214.0210.0FalseNoneNoneFalseNoneFalse2140.20
260161481146NoneCSR2023-24 V-6 Page No 9 Item No 3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TV/Telephone socket ---- etc., complete with all leadEach185.48185.4810.0FalseNoneNoneFalseNoneFalse1854.80
260161581146NoneCSR2023-24 V-6 Page No 10 Item No 3.14.1Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 6A SP Switch ---- etc., complete with all leadEach65.465.418.0FalseNoneNoneFalseNoneFalse1177.20
260161681146NoneCSR2023-24 V-6 Page No 10 Item No 3.14.2Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board6A Two Way Switch ---- etc., complete with all leadEach83.2383.2328.0FalseNoneNoneFalseNoneFalse2330.440
260161781146NoneCSR2023-24 V-6 Page No 10 Item No 3.14.3Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board6A Three Way 5 Pin Socket ---- etc., complete with all leadEach83.2383.2330.0FalseNoneNoneFalseNoneFalse2496.90
260161881146NoneCSR2023-24 V-6 Page No 10 Item No 3.14.4Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 6A Three Pin Top ---- etc., complete with all leadEach103.44103.4420.0FalseNoneNoneFalseNoneFalse2068.80
260161981146NoneCSR2023-24 V-6 Page No 10 Item No 3.14.5Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 6A Bakelite Ceiling Rose ---- etc., complete with all leadEach92.7492.7420.0FalseNoneNoneFalseNoneFalse1854.80
260162081146NoneCSR2023-24 V-6 Page No 10 Item No 3.14.6Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 6A Pendant Holder ---- etc., complete with all leadEach84.4284.4215.0FalseNoneNoneFalseNoneFalse1266.30
260162181146NoneCSR2023-24 V-6 Page No 10 Item No 3.14.7Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board.Batten holder ---- etc., complete with all leadEach87.9987.9915.0FalseNoneNoneFalseNoneFalse1319.850
260162281146NoneCSR2023-24 V-6 Page No 10 Item No 3.14.8Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board.6A bell push ---- etc., complete with all leadEach83.2383.2315.0FalseNoneNoneFalseNoneFalse1248.450
260162381146NoneCSR2023-24 V-6 Page No 10 Item No 3.14.9Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 6A bell buzzer ---- etc., complete with all leadEach154.57154.5715.0FalseNoneNoneFalseNoneFalse2318.550
260162481146NoneCSR2023-24 V-6 Page No 10 Item No 3.14.10Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 16A SP switch ---- etc., complete with all leadEach155.76155.7620.0FalseNoneNoneFalseNoneFalse3115.20
260162581146NoneCSR2023-24 V-6 Page No 10 Item No 3.14.11Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 16A Two Way Switch ---- etc., complete with all leadEach173.59173.5920.0FalseNoneNoneFalseNoneFalse3471.80
260162681146NoneCSR2023-24 V-6 Page No 10 Item No 3.14.12Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 16A Three 5 Pin Socket ---- etc., complete with all leadEach136.74136.7420.0FalseNoneNoneFalseNoneFalse2734.80
260162781146NoneCSR2023-24 V-6 Page No 10 Item No 3.14.13Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board.16 A Three pin top ---- etc., complete with all leadEach130.79130.7915.0FalseNoneNoneFalseNoneFalse1961.850
260162881146NoneCSR2023-24 V-6 Page No 10 Item No 3.14.14Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board.32 A backlight DP ---- etc., complete with all leadEach275.85275.859.0FalseNoneNoneFalseNoneFalse2482.650
260162981146NoneCSR2023-24 V-6 Page No 10 Item No 3.14.15Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 16/6A combined plug and socket with control switch ---- etc., complete with all leadEach259.2259.29.0FalseNoneNoneFalseNoneFalse2332.80
260163081146NoneCSR2023-24 V-6 Page No 17 Item No 5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A SP ---- etc., complete with all leadEach493.44493.446.0FalseNoneNoneFalseNoneFalse2960.640
260163181146NoneCSR2023-24 V-6 Page No 17 Item No 5.18.2Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.40 A SP ---- etc., complete with all leadEach942.88942.886.0FalseNoneNoneFalseNoneFalse5657.280
260163281146NoneCSR2023-24 V-6 Page No 17 Item No 5.18.3Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.50-63 A SP ---- etc., complete with all leadEach964.28964.286.0FalseNoneNoneFalseNoneFalse5785.680
260163381146NoneCSR2023-24 V-6 Page No 17 Item No 5.18.4Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A DP ---- etc., complete with all leadEach878.67878.676.0FalseNoneNoneFalseNoneFalse5272.020
260163481146NoneCSR2023-24 V-6 Page No 17 Item No 5.18.5Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.40 A DP ---- etc., complete with all leadEach1260.341260.346.0FalseNoneNoneFalseNoneFalse7562.040
260163581146NoneCSR2023-24 V-6 Page No 17 Item No 5.18.6Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A DP ---- etc., complete with all leadEach1310.281310.286.0FalseNoneNoneFalseNoneFalse7861.680
260163681146NoneCSR2023-24 V-6 Page No 17 Item No 5.18.7Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A TPN ---- etc., complete with all leadEach2041.512041.516.0FalseNoneNoneFalseNoneFalse12249.060
260163781146NoneCSR2023-24 V-6 Page No 17 Item No 5.18.8Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.40 A TPN ---- etc., complete with all leadEach3619.323619.326.0FalseNoneNoneFalseNoneFalse21715.920
260163881146NoneCSR2023-24 V-6 Page No 18 Item No 5.18.9Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.50-63 A TPN ---- etc., complete with all leadEach3671.633671.636.0FalseNoneNoneFalseNoneFalse22029.780
260163981146NoneCSR2023-24 V-6 Page No 18 Item No 5.19.1Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.4 Way SP & N ---- etc., complete with all leadEach1475.551475.555.0FalseNoneNoneFalseNoneFalse7377.750
260164081146NoneCSR2023-24 V-6 Page No 18 Item No 5.19.2Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. 6 Way SP & N ---- etc., complete with all leadEach1410.151410.155.0FalseNoneNoneFalseNoneFalse7050.750
260164181146NoneCSR2023-24 V-6 Page No 18 Item No 5.19.3Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.8 Way SP & N ---- etc., complete with all leadEach1773.991773.995.0FalseNoneNoneFalseNoneFalse8869.950
260164281146NoneCSR2023-24 V-6 Page No 18 Item No 5.19.4Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.12 Way SP & N ---- etc., complete with all leadEach2215.112215.115.0FalseNoneNoneFalseNoneFalse11075.550
260164381146NoneCSR2023-24 V-6 Page No 18 Item No 5.19.5Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.16 Way SP & N ---- etc., complete with all leadEach3486.153486.155.0FalseNoneNoneFalseNoneFalse17430.750
260164481146NoneCSR2023-24 V-6 Page No 21 Item No 5.46.1Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA.16 - 32 A SP ---- etc., complete with all leadEach249.69249.692.0FalseNoneNoneFalseNoneFalse499.380
260164581146NoneCSR2023-24 V-6 Page No 21 Item No 5.46.4Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA. 16 - 32 A TP ---- etc., complete with all leadEach953.58953.582.0FalseNoneNoneFalseNoneFalse1907.160
260164681146NoneCSR2023-24 V-6 Page No 19 Item No 5.32Supplying and fixing digital frequency M with latest micro controller technology, ultra bright 4 digit LED display, from 30-500V AC and optional or relay output for high/low frequency and wiring complete ---- etc., complete with all leadEach1159.281159.284.0FalseNoneNoneFalseNoneFalse4637.120
260164781146NoneCSR2023-24 V-6 Page No 18 Item No 5.21Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/manual reset facility suitable to mount on DIN rail/ flush mounting on panel board ---- etc., complete with all leadEach11004.211004.24.0FalseNoneNoneFalseNoneFalse44016.80
260164881146NoneCSR2023-24 V-6 Page No 43 Item No 11.3.1Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greaterthan 80. Power Input: 220-240V@ 50/60Hz & Power factor greaterthan0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 2' - 9/10 W ---- etc., complete with all leadEach655.14655.1415.0FalseNoneNoneFalseNoneFalse9827.10
260164981146NoneCSR2023-24 V-6 Page No 43 Item No 11.3.2Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greaterthan 80. Power Input: 220-240V@ 50/60Hz & Power factor greaterthan0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 W ---- etc., complete with all leadEach820.41820.4115.0FalseNoneNoneFalseNoneFalse12306.150
260165081146NoneCSR2023-24 V-6 Page No 30 Item No 6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.48" Sweep (1200 mm) Regular model ---- etc., complete with all leadEach3547.983547.9810.0FalseNoneNoneFalseNoneFalse35479.80
260165181146NoneCSR2023-24 V-6 Page No 30 Item No 6.2.1Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete 12" Sweep (300 mm) ---- etc., complete with all leadEach3530.143530.1410.0FalseNoneNoneFalseNoneFalse35301.40
260165281146NoneCSR2023-24 V-6 Page No 57 Item No 13.1Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. ---- etc., complete with all leadEach203.32203.3210.0FalseNoneNoneFalseNoneFalse2033.20
260165381146NoneCSR2023-24 V-6 Page No 57 Item No 13.13Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame ---- etc., complete with all leadEach840.62840.6210.0FalseNoneNoneFalseNoneFalse8406.20
260165481146NoneCSR2023-24 V-6 Page No 58 Item No 13.19Fixing all types and all capacities of 1'x4' / 2'x2' LED Light fittings indoor on the wall / ceiling / rafters / girders with necessary supporting frame, using 2310.0076" twin twisted PVC insulated wires, required No of round blocks and clA. ---- etc., complete with all leadEach582.61582.6125.0FalseNoneNoneFalseNoneFalse14565.250
260165581146NoneCSR2023-24 V-6 Page No 17 Item No 5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 Amps SP ---- etc., complete with all leadEach493.44493.447.0FalseNoneNoneFalseNoneFalse3454.080
260165681146NoneCSR2023-24 V-6 Page No 17 Item No 5.18.9Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.50-63 Amps TPN ---- etc., complete with all leadEach3671.633671.639.0FalseNoneNoneFalseNoneFalse33044.670
260165781146NoneCSR2023-24 V-6 Page No 15 Item No 5.11.1Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. (Open Execution)upto 63 Amps ---- etc., complete with all leadEach6515.726515.726.0FalseNoneNoneFalseNoneFalse39094.320
260165881146NoneCSR2023-24 V-6 Page No 15 Item No 5.11.3Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. (Open Execution)125 Amps ---- etc., complete with all leadEach12277.6112277.617.0FalseNoneNoneFalseNoneFalse85943.270
260165981146NoneCSR2023-24 V-6 Page No 57 Item No 13.18.4Fixing of ..... A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling.15-63 Amps TPDT/COS ---- etc., complete with all leadEach344.81344.817.0FalseNoneNoneFalseNoneFalse2413.670
260166081146NoneCSR2023-24 V-6 Page No 58 Item No 13.18.5Fixing of ..... A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling.125 Amps TPDT/COS ---- etc., complete with all leadEach560.02560.027.0FalseNoneNoneFalseNoneFalse3920.140
260166181146NoneCSR2023-24 V-5 Page No 113 Item No 10.1.5Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. PVC pipes 75mm dia., 6 kg/sqcm & class 3 ---- etc., complete with all leadm272.58272.58240.0FalseNoneNoneFalseNoneFalse65419.20
260166281146NoneCSR2023-24 V-5 Page No 113 Item No 10.1.7Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc.PVC pipes 110mm dia., 6 kg/sqcm & class 3 ---- etc., complete with all leadm509.22509.22100.0FalseNoneNoneFalseNoneFalse50922.00
260166381146NoneCSR2023-24 V-2 Page No 122 Item No 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15mm dia ---- etc., complete with all leadm382.85382.8565.0FalseNoneNoneFalseNoneFalse24885.250
260166481146NoneCSR2023-24 V-2 Page No 122 Item No 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20mm dia ---- etc., complete with all leadm469.58469.5850.0FalseNoneNoneFalseNoneFalse23479.00
260166581146NoneCSR2023-24 V-2 Page No 122 Item No 13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.25mm dia ---- etc., complete with all leadm591.0591.0100.0FalseNoneNoneFalseNoneFalse59100.00
260166681146NoneCSR2023-24 V-2 Page No 122 Item No 13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.32mm dia ---- etc., complete with all leadm690.12690.12200.0FalseNoneNoneFalseNoneFalse138024.00
260166781146NoneCSR2023-24 V-2 Page No 123 Item No 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. ---- etc., complete with all leadl11.1511.154000.0FalseNoneNoneFalseNoneFalse44600.00
260166881146NoneCSR2023-24 V-5 Page No 191 Item No 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. ---- etc., complete with all leadNo6757.56757.547.0FalseNoneNoneFalseNoneFalse317602.50
260166981146NoneCSR2023-24 V-3 Page No 9 Item No 2.4 (A)Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness..By Manual MeansIn area of light jungle ---- etc., complete with all leadSqm1390.21390.20.8FalseNoneNoneFalseNoneFalse1112.160
260167081146NoneCSR2023-24 V-1 Page No 8 Item No 1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- etc., complete with all leadCum117.7117.724.0FalseNoneNoneFalseNoneFalse2824.80
260167181146NoneCSR2023-24 V-1 Page No Item No 1.15.3Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Depth exceeding 3m, but not exceeding 4.5m ---- etc., complete with all leadCum573.7573.7131.46FalseNoneNoneFalseNoneFalse75418.6020
260167281146NoneCSR2023-24 V-1 Page No 15 Item No 2.1.2Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum7017.77017.75.9039FalseNoneNoneFalseNoneFalse41431.799030
260167381146NoneCSR2023-24 V-1 Page No 16 Item No 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates BOTTOM SLAB,RC WALL,TOP SLAB,Beams ---- etc., complete with all leadCum12717.712717.735.61FalseNoneNoneFalseNoneFalse452877.2970
260167481146NoneCSR2023-24 V-1 Page No 18 Item No 2.11 (a)Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. for Building ---- etc., complete with all leadTonne110837.2110837.24.3493FalseNoneNoneFalseNoneFalse482064.233960
260167581146NoneCSR2023-24 V-2 Page No 149 Item No 15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. ---- etc., complete with all leadSqm1012.31012.3107.0FalseNoneNoneFalseNoneFalse108316.10
260167681146NoneCSR2023-24 V-2 Page No 43 Item No 8.12Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineerin-Charge. ---- etc., complete with all leadKg79.379.335.0FalseNoneNoneFalseNoneFalse2775.50
260167781146NoneCSR2023-24 V-2 Page No 17 Item No 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications ---- etc., complete with all leadSqm1623.11623.10.899FalseNoneNoneFalseNoneFalse1459.16690
260167881146NoneCSR2023-24 V-2 Page No 42 Item No 8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm459.7459.758.37FalseNoneNoneFalseNoneFalse26832.6890
260167981146NoneCSR2023-24 V-2 Page No 41 Item No 8.3.1Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge ---- etc., complete with all leadSqm438.6438.685.0FalseNoneNoneFalseNoneFalse37281.00
260168081146NoneCSR2023-24 V-2 Page No 46 Item No 8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm215.6215.658.379FalseNoneNoneFalseNoneFalse12586.51240
260168181146NoneCSR2023-24 Page No Item No XXXVIIIProviding and fixing C. I Manhole covers 24" x 24" ---- etc., complete with all leadNo3100.03100.02.0FalseNoneNoneFalseNoneFalse6200.00
260168281146NoneCSR2023-24 V-2 Page No 83 Item No 11.16.3Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Electric resistance or induction butt welded tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all leadKg151.2151.222.5FalseNoneNoneFalseNoneFalse3402.00
260168381146NoneCSR2023-24 V-2 Page No 85 Item No 11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all leadKg700.0700.031.2FalseNoneNoneFalseNoneFalse21840.00
260168481146None146BAR SCREEN CHAMBER: MSFRP Bar Screen chamber rectangular tank,made up of Mild steel coated with FRP lining,Bar Screen Chamber Diemesion:1000x1000x1000 Length :1000 mm,Width :1000 mm,Height :1000 mm,Mild steel sheet Thickness: 3mm,FRP Lining ,Internal Thickness : 2mm,External Thcness: 2mm,inlet nozzelDia :4 inch,outLetnozzel Dia: 4 Bar Screen Size : 10mm,screen MOC : Mild Steel,Screen coating : Epoxy,Make : Orionwater. ---- etc., complete with all leadSet53100.053100.01.0FalseNoneNoneFalseNoneFalse53100.00
260168581146None147RAW SEWAGE TRANSFER PUMP Raw Sewage transfer pump capable of handling,sewage transfer from collection tank to RBC STP,maximum solid handling size upto 50 mm,Type : Centrifugal monoblock,Impeller :open,motor HP:1,RPM:2700,Flow Rate:2 m3/hr,Head:10,Moc : Cl,solid Particle Size Handling: 7 mm A).Valve : Suction : 2 No,Delivery : 2 No,Size :50 mm,Moc : B).Type : Ball /Butterfly, Non Return Valve, Delivery : 2 No, Size :50 mm, Moc : Make : Kriloskar / CRI, Pump (1 w + 1S) 2No of pump = 1 set. ---- etc., complete with all leadSet59000.059000.01.0FalseNoneNoneFalseNoneFalse59000.00
260168681146None148STP Rectamgular Tank Size and dimension:Width : 1500 mm, Over Height including Top Cover : 3000 mm, Length :6100 mm, MOC of rectangular Tank : Mild Steel, Shell Thickness: 5 mm FRP lining, Internal Liniing : 3 mm, External Lining : 3 mm, Pipe inlet Dia: 80 mm, Pipe Outlet Dia: 80 mm, Drain Header pipe Dia: 80 mm ---- etc., complete with all leadSet1046660.01046660.01.0FalseNoneNoneFalseNoneFalse1046660.00
260168781146None149Primary clarifier : Type : Lamella, No of Plates: 10, Lamella plate MOC: FRP, Lemella Plate Thickness: 2 mm ---- etc., complete with all leadSet457840.0457840.01.0FalseNoneNoneFalseNoneFalse457840.00
260168881146None150Secondary clarifier: Type : Lamella, No of Plates: 19, Lamella plate MOC: FRP, Lemella Plate Thickness: 3 mm ---- etc., complete with all leadSet450760.0450760.01.0FalseNoneNoneFalseNoneFalse450760.00
260168981146None151ROTOR: No of Rotors: 2, Moc: FRP, DiaM of Rotor : 1000mm, Connected with , Shaft : EN 90 Rod, Driven by : pillar Block, No of pillar block: 4 ---- etc., complete with all leadSet488520.0488520.01.0FalseNoneNoneFalseNoneFalse488520.00
260169081146None152Bio Zone (Rotor Placement Boat) No. of Biozone : 1 No, No. of Partisian inside Bio-zone : 4 No, MOC : MSFRP, Boat curvature DiaM : 1800mm, Bio Zone supporting with 150mm, Beam 2 No & 4 No. Legs., Boat Size:3350 mm ---- etc., complete with all leadSet436600.0436600.01.0FalseNoneNoneFalseNoneFalse436600.00
260169181146None153Gear Box : Type: Helical, No of Gear Box: 1 no, Make : Bonfigoli (Germany), Gear Box Motor HP: 1, Gear Box motor Make : Seimens. ---- etc., complete with all leadSet112100.0112100.01.0FalseNoneNoneFalseNoneFalse112100.00
260169281146None154Internal Piping & Base Works : 1) Inter connecting pipe works with FRP lining inside process tank, Recirculion& drain system. 2)Base Plate works for Gear box arrangement,Rotor Fixing arrangement,Biozone leg placement arrangement. RBC STP Make : Orionwater ---- etc., complete with all leadSet68440.068440.01.0FalseNoneNoneFalseNoneFalse68440.00
260169381146None155FILTER FEED PUMP: Filter feed pump capable of handling to transfer clarifed to filtration plant maximum solid handling size upto 20 mm, Type : Centrifugal monoblock, Impeller : Closed motor HP:3, RPM:1700, Flow Rate: 6m3/hr, Head:30, Moc : solid Particle Size Handling: 50mm Valve , Suction : 2 No, Delivery : 2 No, Size :50 mm, Moc : Type : Ball /Butterfly, Non Return Valve, Delivery : 2 No, Size :50 mm, Moc : , Make : Kriloskar / CRI, Pump (1 w + 1S) 2No of pump = 1 set ---- etc., complete with all leadSet29500.029500.01.0FalseNoneNoneFalseNoneFalse29500.00
260169481146None156SAND FILTER : DiaM: 600 mm, Height On Straight: 1900 mm, Shell hickness: 6mm, Dish end Thickness: 8mm, Frontal Pipeline:, MOC: Mild Steel, External Coating : Red Oxide and Enamel paint, Internal Coating: Black Bitumus, Fiter Media: Fine Sand, Gravel sand, pebbles,silex, Media in KG: 450, Media Depth : 915 mm, Type : Cylindrical, Vertical. ---- etc., complete with all leadSet159300.0159300.01.0FalseNoneNoneFalseNoneFalse159300.00
260169581146None157ACTIVATED CARBON FILTER: DiaM: 600 mm,Height On Straight: 1900 mm, Shell hickness: 6mm,Dish end Thickness: 8mm Frontal Pipeline: MOC: Mild Steel,External Coating :Red Oxide and Enamel paint,Internal Coating: Black Bitumus,Fiter Media: Activated Carbon Media in KG: 150,Media Depth : 1000 mm,Type : Cylindrical. ---- etc., complete with all leadSet159300.0159300.01.0FalseNoneNoneFalseNoneFalse159300.00
260169681146None158CHLORINE DOSING SYSTEM, Pump type : ElectonicDiaphram Capacity : 0- 2LPH, Nominal Back pressure : 6 KG/CM2, Maximum Back pressure: 8 KG/CM2 KW: 0.24 watt, Tank Capacity : 100 Liters, MOC: PP, Make : LMI Asia ---- etc., complete with all leadSet33040.033040.01.0FalseNoneNoneFalseNoneFalse33040.00
260169781146None159INTERCONNECTING PIPE WORK All necessary pipe work from Bar Screen chamber to collection tank, collection tank to Raw sewage transfer pump, Raw sewage transfer pump to RBC STP, RBC STP to Filter feed pump, Filter feed pump to Filtration plant and filtration plant to treated water tank The scope shall be PVC pipes with all necessary valves, NRV , Float switch and drain Header. ---- etc., complete with all leadSet147500.0147500.01.0FalseNoneNoneFalseNoneFalse147500.00
260169881146None160CONTROL PANEL: Installation, testing and commissioning of Electrical Panel suitable for 415V, 3 phase, 4 wire, 50Hz distribution system. The panel shall be Wall Mounting type, sheet metal enclosed, flush front with aluminium busbars, separate earth bus shall be provided throughout the length of the panel. The incoming and the outgoing feeder breakers, switch fuse units, change over switches, indicating lamps, Ms etc. shall be accommodated in a modular multi-tier arrangement. The painting shall be done in conformity with IS code. Adequate size cable alley shall be provided all around the panel and at the back for easy bending and terminations. The outgoing feeders inside the panel shall be connected through solid busbars. Busbars shall be provided with PVC heat shrinkable sleeves or heat resistant insulated paint. The panels shall be suitable for cable entry from top / bottom. ---- etc., complete with all leadSet206500.0206500.01.0FalseNoneNoneFalseNoneFalse206500.00
260169981146None161FREIGHT LOADING AND UNLOADING : All the equipment shall be loaded ,transported and unloaded at site. Including the necessary Cranes required to erect and position the system ---- etc., complete with all leadSet88500.088500.01.0FalseNoneNoneFalseNoneFalse88500.00
260170081146None162INSTALLATION, ERECTION, COMMISSIONING, TESTING AND HANDING OVER AT SITE. From the Inlet of the Bar Screen chamber to the output of Caron filter ---- etc., complete with all leadSet118000.0118000.01.0FalseNoneNoneFalseNoneFalse118000.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17079850460000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17079850460000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17079850460001NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of Karnataka public Procurement on or before the last date and time of bid submission.None
17079851810000NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of Karnataka public Procurement portal due to internet connectivity issues and technical glitches at bidders endNone
17079851940000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejectionNone
17079852060000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidderNone
17079852140000NoneNoneELIGIBILITYThe tenderer shall bear all costs associated with the preparation and submission of his tender, and the employer will in no case be responsible and liable for those costsNone
17079852220000NoneNoneELIGIBILITYConditional tenders will not be accepted.None
17079852320000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete manner.None
17079852430000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt., orders as may be modified from time to time.None
17079853020000NoneNoneELIGIBILITYAny discrepancies observed in the documents uploaded by the tenderer the tender shall liable to rejected.None
17079853180000NoneNoneELIGIBILITYEarnest Money Deposit will have to be in any one of the forms as per the instructions in the financial bid document and shall have to be valid for 45 days beyond the validity of the tender.None
17079853270000NoneNoneELIGIBILITYAll formats prescribed in the bid documents shall be filled in complete manner (section 2 & of the bid document)and shall be uploaded properly, signed by tenderer. Necessary certificates shall be uploaded along with the formats wherever required. General documents section can be used for this purposeNone
17079853360000NoneNoneELIGIBILITYTenderers are required to read the Bid Documents carefully before submission of their bidNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneClause ITT 3.2(b)To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2018-19 to 2022-23) The tenderer should have been Satisfactorily completed at least one Satisfactorily completed at least one Similar work of value not less than Rs.126.50 Lakhs as prime contractor. Note : The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (b).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(c) To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2018-19 to 2022-23).Executed in any one year, the following minimum quantities of work Sl. No Description of key items of works Quantity 1)Earthwork Excavation 440.00 Cum,2)RCC and PCC 116.00 Cum 3)Steel Reinforcement for RCC work 7.00 Tonnes 5)Flooring/Dadooing(Vitrified/Granite/ Ceramic/Cement concrete/cladding/ dadooing) 2000.00 Sqm,6)Plastering 1000.00 Sqm,7)Painting 5900.00 Sqm, 8)WPC-240.00 sqm. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2(c)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(d) The tenderer or his identified sub contractor should possess required valid electrical license for executing building electrification works issued by KPWD/ Government electrical Inspectorate and should have executed similar Building electrical works totaling Rs.13.00 Lakhs in any one year.Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (d).The letter of willingness of the sub contractor to be engaged for electrical, should be obtained and uploaded in the KPP-portal.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(e)The Tenderer or his identified sub-contractor should possess valid license for executing water supply/sanitary engineering works issued by BWSSB/ KUWS&DB and should have executed similar building water supply/sanitary engineering works totaling Rs.10.00 Lakhs in any one year. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (e).The letter of willingness of the sub contractor to be engaged for water supply & Sanitary, should be obtained and uploaded in the KPP-portal.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(f) The Tenderer or his identified sub-contractor should have executed similar STPworks totaling to Rs.50.00 Lakhs in any one year. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (f). The letter of willingness of the sub contractor to be engaged for STP works should be obtained and uploaded in the KPP-portal.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneList of existing commitments and ongoing worksClause 3.6 Tenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated for prime contractor are as under Assessed available tender capacity AxNx1.5- B Where A maximum value of civil engineering works executed in any one year during the last five years 2018-19 to 2022-23 updated to 2023-24 price level taking into account the completed as well as works in progress. N Number of years prescribed for completion of the works for which tenders are invited. B Value, at 2023 24 price level, of existing commitments and ongoing works to be completed during the next 06 months. Note:The statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed should be countersigned by the Employer in charge, not below the rank of an Executive Engineer or equivalent. certificate issued by the officer not lessthan the rank of Executive Engineer Ongoing commitments and Bids submitted for the worksCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- certificate issued by the officer not lessthan the rank of Executive Engineer Ongoing commitments and Bids submitted for the works
NoneNoneNoneNoneClause ITT 3.3 (a)Equipment capacity Each tenderer should further demonstrate(a) available by owning at least 50% of the required/specified key and critical equipment for this work and (b) the remaining 50% can be deployed on ease/hire basis for all works provided, the relevant documents (commitment agreements etc.,) for availability for this work are furnished. Sl.No. Description of Equipment Quantity 1 No Min 10 cft capacity Concrete Mixer-1 No. 2.Tipper-1 Nos 3.Excavator-1 No.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Invoice and Receipt document to be uploaded.
NoneNoneNoneNoneList of Minimum Key Personnel to be deployed by the contractor at site for Contract work Sl No Position Qualification and Requirement No Of Persons 1)Site Engineer BE Civil with minimum experience of 7 years in the Construction of buildings Or Diploma in Civil Engineering with minimum experience of 10 years in the Construction of buildings and should have been working in permanent role of the organization for at least two years 2 Two Nos 2)Electrical Engineer BE Electrical with minimum experience of 5 years in the Construction of buildings Or Diploma in Electrical Engineering with minimum experience of 10 years in the Construction of buildings- 1No and should have been working inpermanent role of the organization for at least two years.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Educational and Experience certificates should be uploaded
NoneNoneNoneNoneClause ITT 3.2(a):The tenderer should have been achieved in at least two financial years a minimum annual financial turnover (in all classes of civil Engineering construction works only) of Rs.506.00 Lakhs. Note : a) For Clause 3.2 (a) the certificate Turn over and balance sheet duly certified by the charted accountant is to be submitted.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneClause 3.3(b)Liquid assets and /or availability of credit facilities of not less than Rs.76.00 Lakhs (Credit lines / letter of credit/ certificates from banks for meeting the fund requirement etc.(As per the prescribed format in clause 1.10 of SECTION 3, QUALIFICATION INFORMATION of this document.) as prime Contractor.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover Certificate and balance sheet issued by Charted accountant.TrueTechnical Bid
KPWD Class-II and above Registration Certificate issued by Chief Engineer.TrueTechnical Bid
Tenderer should have ESI & PF Certificates his/firm name and PF paid receipt of last month.TrueTechnical Bid
Tenderer should have latest GST Registration PAN Card and latest 3 GSTclearance certificate in their name.TrueTechnical Bid
The Work done certificate should be issued by the Officer not less than the rank of Executive EngineerTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1708066904000
version0
createdDateNone
modifiedDateNone
blockNumberOffice of the Chief Engineer, Engineering Wing, Arogya Soudha, 3rd floor, Leprosy Hospital premises, 1st cross, Magadi Road
streetNone
cityBengaluru
stateKarnataka
pin560023
tenderRecallDTONone