tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1707831630000 | 0 | None | None | Buildings | Ground Floor (Civil Works) | 2317033.93 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2580576 | 79838 | None | 1.14.1 (Vol-1) | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift up to 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth up to 3m | Cum | 107.1 | 107.1 | 59.99 | False | None | None | False | None | False | 6424.929 | 0 | 2580577 | 79838 | None | 9(A130A) Vol-5 | KSRB 2.8 : Providing and Filling in foundation with granite / trap broken metal 100mm. and down size, with approved sand including handpacking, ramming, watering, including cost of all materials and labour with all lead and lift. complete as per specifications. | Cum | 1672.65 | 1672.65 | 40.0 | False | None | None | False | None | False | 66906.0 | 0 | 2580578 | 79838 | None | 2.1.3 (Vol-1) | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6288.45 | 6288.45 | 38.83 | False | None | None | False | None | False | 244180.5135 | 0 | 2580579 | 79838 | None | 2.3.2 (Vol-1) | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6804.0 | 6804.0 | 5.66 | False | None | None | False | None | False | 38510.64 | 0 | 2580580 | 79838 | None | Centering & Scaffolding | Additional for formwork, Centering & Scaffolding for Sl No 2: Foundation, Sub structure of cross drainages As per Appendix-I in Volume-1 of page No.-115 (@5% of Finished Rate) | Cum | 340.2 | 340.2 | 5.66 | False | None | None | False | None | False | 1925.532 | 0 | 2580581 | 79838 | None | 2.11a (Vol-1) | Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | t | 93929.85 | 93929.85 | 0.34 | False | None | None | False | None | False | 31936.149 | 0 | 2580582 | 79838 | None | 4.32 (Vol-4) | Providing and filling murrum / gravely soil (CNS soil ) for foundation or around pipes including cost of all materials, labour, spreading soil in layers of 100 to 150 mm, breaking clods, watering, compaction by earth masters to achieve density control of not less than 90 percent etc.,complete with all lead and lifts. | Cum | 737.1 | 737.1 | 99.81 | False | None | None | False | None | False | 73569.951 | 0 | 2580583 | 79838 | None | 6.8 (Vol-2) | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8367.45 | 8367.45 | 24.17 | False | None | None | False | None | False | 202241.2665 | 0 | 2580584 | 79838 | None | 2.4.1 (Vol-1) | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6724.2 | 6724.2 | 0.88 | False | None | None | False | None | False | 5917.296 | 0 | 2580585 | 79838 | None | 8.2.1(Vol-2) | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 309.75 | 309.75 | 107.33 | False | None | None | False | None | False | 33245.4675 | 0 | 2580586 | 79838 | None | 9.34 (Vol-2) | Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour,curing, polishing complete as per specifications | Sqm | 1622.25 | 1622.25 | 220.6 | False | None | None | False | None | False | 357868.35 | 0 | 2580587 | 79838 | None | 9.6.1 (Vol-2) | Providing and laying Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) | Sqm | 1332.45 | 1332.45 | 21.12 | False | None | None | False | None | False | 28141.344 | 0 | 2580588 | 79838 | None | 9.23 (Vol-2) | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :
** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent | Sqm | 2589.3 | 2589.3 | 84.1 | False | None | None | False | None | False | 217760.13 | 0 | 2580589 | 79838 | None | 10.2 (Vol-2) | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. | m | 344.4 | 344.4 | 23.0 | False | None | None | False | None | False | 7921.2 | 0 | 2580590 | 79838 | None | 11.34B (Vol-2) | Providing and fixing M.S. grills of required pattern in frames of win- dows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. | Kg | 192.15 | 192.15 | 1830.36 | False | None | None | False | None | False | 351703.674 | 0 | 2580591 | 79838 | None | 8.25 (Vol-2) | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 143.85 | 143.85 | 1099.83 | False | None | None | False | None | False | 158210.5455 | 0 | 2580592 | 79838 | None | 8.28 (Vol-2) | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 93.45 | 93.45 | 808.8 | False | None | None | False | None | False | 75582.36 | 0 | 2580593 | 79838 | None | 8.27 (Vol-2) | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 55.65 | 55.65 | 107.33 | False | None | None | False | None | False | 5972.9145 | 0 | 2580594 | 79838 | None | 8.34.3 (Vol-2) | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 52.5 | 52.5 | 87.16 | False | None | None | False | None | False | 4575.9 | 0 | 2580595 | 79838 | None | 8.4 (Vol-2) | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 120.75 | 120.75 | 87.16 | False | None | None | False | None | False | 10524.57 | 0 | 2580596 | 79838 | None | 11.28 (Vol-2) | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 593.25 | 593.25 | 631.35 | False | None | None | False | None | False | 374548.3875 | 0 | 2580597 | 79838 | None | 11.15.2 (Vol-2) | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer: Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Kg | 123.9 | 123.9 | 156.31 | False | None | None | False | None | False | 19366.809 | 0 |
| 1707831630000 | 1 | None | None | Buildings | First Floor (Civil Works) | 7811680.38 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2580598 | 79839 | None | 2.4.1 (Vol-1) | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6791.44 | 6791.44 | 6.83 | False | None | None | False | None | False | 46385.5352 | 0 | 2580599 | 79839 | None | 2.5.2 (Vol-1) | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7257.0 | 7257.0 | 125.59 | False | None | None | False | None | False | 911406.63 | 0 | 2580600 | 79839 | None | Centering & Scaffolding | Additional for formwork, Centering & Scaffolding for Sl No 8 : Columns As per Corrigendum-3 / Appendix-I in Volume-1 of page No.-115 (@70% of Finished Rate) | Cum | 5079.9 | 5079.9 | 15.73 | False | None | None | False | None | False | 79906.827 | 0 | 2580601 | 79839 | None | Centering & Scaffolding | Additional for formwork, Centering & Scaffolding for Sl No 12 : beam & lintels of buildings As per Corrigendum-3 / Appendix-I in Volume-1 of page No.-115 (@60% of Finished Rate) | Cum | 4354.2 | 4354.2 | 34.98 | False | None | None | False | None | False | 152309.916 | 0 | 2580602 | 79839 | None | Centering & Scaffolding | Additional for formwork, Centering & Scaffolding for Sl No 20 : Chejjas, Canopy & Other Architectural projections of minor sections As per Corrigendum-3 / Appendix-I in Volume-1 of page No.-115 (@45% of Finished Rate) | Cum | 3265.65 | 3265.65 | 3.46 | False | None | None | False | None | False | 11299.149 | 0 | 2580603 | 79839 | None | Centering & Scaffolding | Additional for formwork, Centering & Scaffolding for Sl No 13 : Roof slab of buildings As per Corrigendum-3 / Appendix-I in Volume-1 of page No.-115 (@50% of Finished Rate) | Cum | 3628.5 | 3628.5 | 71.21 | False | None | None | False | None | False | 258385.485 | 0 | 2580604 | 79839 | None | 2.11a (Vol-1) | Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | t | 94869.15 | 94869.15 | 16.51 | False | None | None | False | None | False | 1566289.6665 | 0 | 2580605 | 79839 | None | 6.8 (Vol-2) | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8451.12 | 8451.12 | 175.86 | False | None | None | False | None | False | 1486213.9632 | 0 | 2580606 | 79839 | None | 8.2.1 (Vol-2) | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 312.85 | 312.85 | 810.02 | False | None | None | False | None | False | 253414.757 | 0 | 2580607 | 79839 | None | 8.8 (Vol-2) | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 393.45 | 393.45 | 893.56 | False | None | None | False | None | False | 351571.182 | 0 | 2580608 | 79839 | None | 9.34 (Vol-2) | Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour,curing, polishing complete as per specifications. | Sqm | 1638.47 | 1638.47 | 472.57 | False | None | None | False | None | False | 774291.7679 | 0 | 2580609 | 79839 | None | 9.6.1 (Vol-2) | Providing and laying Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) | Sqm | 1345.77 | 1345.77 | 20.65 | False | None | None | False | None | False | 27790.1505 | 0 | 2580610 | 79839 | None | 11.34B (Vol-2) | Providing and fixing M.S. grills of required pattern in frames of win- dows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. | Kg | 194.07 | 194.07 | 3098.97 | False | None | None | False | None | False | 601417.1079 | 0 | 2580611 | 79839 | None | 12.12 (Vol-2) | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges
complete as per specifications | Cum | 131716.22 | 131716.22 | 0.5 | False | None | None | False | None | False | 65858.11 | 0 | 2580612 | 79839 | None | 10.6.3 (Vol-2) | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete.- Fastener with threaded dia 12 mm | Each | 63.63 | 63.63 | 36.0 | False | None | None | False | None | False | 2290.68 | 0 | 2580613 | 79839 | None | 12.21 (Vol-2) | Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with , stiles and rails of 30mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. | Sqm | 6089.39 | 6089.39 | 15.12 | False | None | None | False | None | False | 92071.5768 | 0 | 2580614 | 79839 | None | 12.84 (Vol-2) | Providing and fixing of 2 track x 2 panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2 (Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mm height with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware and single point locking system with Crescent Locks. (The cost is inclusive of all fixtures and separate charges for minor T and P shall not be made) Wall thickness of frame sash shall be of 2 mm. | Sqm | 5326.89 | 5326.89 | 47.52 | False | None | None | False | None | False | 253133.8128 | 0 | 2580615 | 79839 | None | 8.51 (Vol-2) | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 106.05 | 106.05 | 1217.2 | False | None | None | False | None | False | 129084.06 | 0 | 2580616 | 79839 | None | 8.25 (Vol-2) | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 145.29 | 145.29 | 1217.2 | False | None | None | False | None | False | 176846.988 | 0 | 2580617 | 79839 | None | 8.27 (Vol-2) | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 56.21 | 56.21 | 893.56 | False | None | None | False | None | False | 50227.0076 | 0 | 2580618 | 79839 | None | 8.28 (Vol-2) | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 94.38 | 94.38 | 893.56 | False | None | None | False | None | False | 84334.1928 | 0 | 2580619 | 79839 | None | 8.34.3 (Vol-2) | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 53.03 | 53.03 | 147.57 | False | None | None | False | None | False | 7825.6371 | 0 | 2580620 | 79839 | None | 8.4 (Vol-2) | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 121.96 | 121.96 | 147.57 | False | None | None | False | None | False | 17997.6372 | 0 | 2580621 | 79839 | None | 8.49 (Vol-2) | Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Per cm Height Per Letter | 4.24 | 4.24 | 2000.0 | False | None | None | False | None | False | 8480.0 | 0 | 2580622 | 79839 | None | 8.43 (Vol-2) | Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade :Two coats on new work including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 99.69 | 99.69 | 14.4 | False | None | None | False | None | False | 1435.536 | 0 | 2580623 | 79839 | None | 15.1 (Vol-2) | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 866.43 | 866.43 | 437.65 | False | None | None | False | None | False | 379193.0895 | 0 | 2580624 | 79839 | None | 13.48 (Vol-2) | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, single socketed pipes 100mm diameter. | m | 308.61 | 308.61 | 72.0 | False | None | None | False | None | False | 22219.92 | 0 |
| 1707831630000 | 0 | None | None | Buildings | Electrical Estimate | 255580.8 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2580625 | 79840 | None | 1.2.1 | Concealed Conduit System :Supplying heavy gauge PVC conduit pipe mm dia mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary19/20mm dia 2mm thick | m | 66.0 | 66.0 | 150.0 | False | None | None | False | None | False | 9900.0 | 0 | 2580626 | 79840 | None | 1.2.2 | Concealed Conduit System :Supplying heavy gauge PVC conduit pipe . mm dia.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary25mm dia 2mm thick | m | 78.0 | 78.0 | 75.0 | False | None | None | False | None | False | 5850.0 | 0 | 2580627 | 79840 | None | 1.3.1 | Supplying heavy gauge PVC Conduit Pipe 25dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.19/20mm dia 2mm thick | m | 68.0 | 68.0 | 75.0 | False | None | None | False | None | False | 5100.0 | 0 | 2580628 | 79840 | None | 1.3.2 | Supplying heavy gauge PVC Conduit Pipe 25dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25mm dia 2mm thick
| m | 79.0 | 79.0 | 75.0 | False | None | None | False | None | False | 5925.0 | 0 | 2580629 | 79840 | None | 1.9.2 | Supplying PVC/GI flexible conduit pipe . mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely25mm | m | 22.0 | 22.0 | 10.0 | False | None | None | False | None | False | 220.0 | 0 | 2580630 | 79840 | None | 2.2.1 | Point wiring using Copper wire with out switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm (Phase&Neutral) &1x1.0 Sqmm(earth Wire)Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto3mtr from tapping point to out let via Switch | Point | 269.0 | 269.0 | 40.0 | False | None | None | False | None | False | 10760.0 | 0 | 2580631 | 79840 | None | 2.2.2 | Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch
| Point | 379.0 | 379.0 | 25.0 | False | None | None | False | None | False | 9475.0 | 0 | 2580632 | 79840 | None | 2.2.3 | Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box | Point | 555.0 | 555.0 | 25.0 | False | None | None | False | None | False | 13875.0 | 0 | 2580633 | 79840 | None | 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,1.5 SQMM multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP. | m | 26.0 | 26.0 | 300.0 | False | None | None | False | None | False | 7800.0 | 0 | 2580634 | 79840 | None | 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,2.5 SQMM multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP. | m | 42.0 | 42.0 | 300.0 | False | None | None | False | None | False | 12600.0 | 0 | 2580635 | 79840 | None | 2.3.4 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,4 SQMM multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP. | m | 63.0 | 63.0 | 300.0 | False | None | None | False | None | False | 18900.0 | 0 | 2580636 | 79840 | None | 3.4.1 | Supplying and flush mounting powder coated / galvanized metal box size 1-3way suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall | Each | 138.0 | 138.0 | 10.0 | False | None | None | False | None | False | 1380.0 | 0 | 2580637 | 79840 | None | 3.4.3 | Supplying and flush mounting powder coated / galvanized metal box size 4-5way suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall | Each | 177.0 | 177.0 | 5.0 | False | None | None | False | None | False | 885.0 | 0 | 2580638 | 79840 | None | 3.4.5 | Supplying and flush mounting powder coated / galvanized metal box size 8way suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall | Each | 261.0 | 261.0 | 5.0 | False | None | None | False | None | False | 1305.0 | 0 | 2580639 | 79840 | None | 3.4.6 | Supplying and flush mounting powder coated / galvanized metal box size10-12way suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall | Each | 319.0 | 319.0 | 10.0 | False | None | None | False | None | False | 3190.0 | 0 | 2580640 | 79840 | None | 3.5.2 | Supplying and fixing superior quality 3Mudular modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal box. | Each | 161.0 | 161.0 | 5.0 | False | None | None | False | None | False | 805.0 | 0 | 2580641 | 79840 | None | 3.5.3 | Supplying and fixing superior quality 4Mudular modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal box. | Each | 175.0 | 175.0 | 5.0 | False | None | None | False | None | False | 875.0 | 0 | 2580642 | 79840 | None | 3.5.5 | Supplying and fixing superior quality 8Mudular modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalbox.
| Each | 284.0 | 284.0 | 5.0 | False | None | None | False | None | False | 1420.0 | 0 | 2580643 | 79840 | None | 3.5.6 | Supplying and fixing superior quality 10-12Mudular modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalbox.
| Each | 344.0 | 344.0 | 10.0 | False | None | None | False | None | False | 3440.0 | 0 | 2580644 | 79840 | None | 3.6.1 | Supplying and fixing of 6Amps 0ne way modular switch on existing modular switch plate as per IS 3854 and IS 1293.
| Each | 102.0 | 102.0 | 100.0 | False | None | None | False | None | False | 10200.0 | 0 | 2580645 | 79840 | None | 3.6.3 | Supplying and fixing of 6Amps 3way modular Socketc on existing modular switch plate as per IS 3854 and IS 1293.
| Each | 171.0 | 171.0 | 50.0 | False | None | None | False | None | False | 8550.0 | 0 | 2580646 | 79840 | None | 3.6.4 | Supplying and fixing of modular stepped electronic fan regulator on existing modular switch plate as per and IS 1293.
| Each | 357.0 | 357.0 | 10.0 | False | None | None | False | None | False | 3570.0 | 0 | 2580647 | 79840 | None | 3.6.7 | Supplying and fixing of 16Amps 0ne way modular switch on existing modular switch plate as per IS 3854 and IS 1293.
| Each | 180.0 | 180.0 | 10.0 | False | None | None | False | None | False | 1800.0 | 0 | 2580648 | 79840 | None | 3.6.9 | Supplying and fixing of32Amps modular DP Switch on existing modular switch plate as per IS 3854 and IS 1293.
| Each | 326.0 | 326.0 | 10.0 | False | None | None | False | None | False | 3260.0 | 0 | 2580649 | 79840 | None | 3.6.10 | Supplying and fixing of6/16amps modular Universal Socket on existing modular switch plate as per IS 3854 and IS 1293.
| Each | 236.0 | 236.0 | 10.0 | False | None | None | False | None | False | 2360.0 | 0 | 2580650 | 79840 | None | 3.14.6 | Supplying and fixing of 6AmpsLamp holder on existing board.
| Each | 71.0 | 71.0 | 50.0 | False | None | None | False | None | False | 3550.0 | 0 | 2580651 | 79840 | None | 5.7.3 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.63amps
| Each | 401.0 | 401.0 | 10.0 | False | None | None | False | None | False | 4010.0 | 0 | 2580652 | 79840 | None | 5.18.1 | Supplying and fixingof 6to32 Amps Single pole miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.
| Each | 415.0 | 415.0 | 10.0 | False | None | None | False | None | False | 4150.0 | 0 | 2580653 | 79840 | None | 5.18.4 | Supplying and fixingof 6to32 Amps Double pole miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.
| Each | 739.0 | 739.0 | 5.0 | False | None | None | False | None | False | 3695.0 | 0 | 2580654 | 79840 | None | 5.19.9 | Supplying and fixing 12way regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.I - doble Door12way sp&n
| Each | 2329.0 | 2329.0 | 5.0 | False | None | None | False | None | False | 11645.0 | 0 | 2580655 | 79840 | None | 12.56 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12mm dia
| Each | 3510.0 | 3510.0 | 5.0 | False | None | None | False | None | False | 17550.0 | 0 | 2580656 | 79840 | None | 32.05 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 16 sqmm 4core
| Km | 141842.0 | 141842.0 | 0.1 | False | None | None | False | None | False | 14184.2 | 0 | 2580657 | 79840 | None | 21.05 (Vol-6) | Labour charges for Laying of LT Cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff
| Km | 20886.0 | 20886.0 | 0.1 | False | None | None | False | None | False | 2088.6 | 0 | 2580658 | 79840 | None | 1.17.1 (Vol 1) | Earth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. All kinds of soils. Depth upto 1.50 m
| Cum | 262.0 | 262.0 | 15.0 | False | None | None | False | None | False | 3930.0 | 0 | 2580659 | 79840 | None | Sl No. 9 (Page-176) Vol-4 WRD | Providing and fixing perforated 50 mm dia. GI pipes 'A' class in drilled holes for drainage including cost of all materials, machinery, labour, making perforations, providing flap valve and jointing etc.,complete with all leads and lifts.
| m | 543.0 | 543.0 | 1.0 | False | None | None | False | None | False | 543.0 | 0 | 2580660 | 79840 | None | 6.3.1 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Economy model
| Each | 2984.0 | 2984.0 | 10.0 | False | None | None | False | None | False | 29840.0 | 0 | 2580661 | 79840 | None | 11.3.2 | LED for indoor | Each | 690.0 | 690.0 | 10.0 | False | None | None | False | None | False | 6900.0 | 0 | 2580662 | 79840 | None | 11.11.4 | Supplying and fixing of of 9watts LED Bulbs.
| Each | 154.0 | 154.0 | 20.0 | False | None | None | False | None | False | 3080.0 | 0 | 2580663 | 79840 | None | 13.7.1 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.
| Each | 263.0 | 263.0 | 20.0 | False | None | None | False | None | False | 5260.0 | 0 | 2580664 | 79840 | None | 13.1 | Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.
| Each | 171.0 | 171.0 | 10.0 | False | None | None | False | None | False | 1710.0 | 0 |
| 1707831630000 | 0 | None | None | Buildings | Water Supply Estimate | 150998.4 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2580665 | 79841 | None | 13.3.1 | Providing and fixing brass stop cock of approved quality :15 mm nominal bore | Nos | 313.95 | 313.95 | 2.0 | False | None | None | False | None | False | 627.9 | 0 | 2580666 | 79841 | None | 13.20.2 | Providing and fixing PTMT pillar cock of approved quality and colour. 15 mm nominal bore, 125 mm long foam flow, weighing not less than 120 gms | Nos | 329.7 | 329.7 | 2.0 | False | None | None | False | None | False | 659.4 | 0 | 2580667 | 79841 | None | 14.7.8 | White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow including oper ated levers | Nos | 4318.65 | 4318.65 | 2.0 | False | None | None | False | None | False | 8637.3 | 0 | 2580668 | 79841 | None | 14.8 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. | Nos | 1494.15 | 1494.15 | 2.0 | False | None | None | False | None | False | 2988.3 | 0 | 2580669 | 79841 | None | 13.31.2 | Providing & fixing Chorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction Engineer in Charge.Exposed on wall - 20mm nominal dia pipes | m | 254.1 | 254.1 | 40.0 | False | None | None | False | None | False | 10164.0 | 0 | 2580670 | 79841 | None | 13.31.3 | Providing & fixing Chorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction Engineer in Charge.Exposed on wall - 25mm nominal dia pipes | m | 333.9 | 333.9 | 30.0 | False | None | None | False | None | False | 10017.0 | 0 | 2580671 | 79841 | None | 13.31.4 | Providing & fixing Chorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction Engineer in Charge.Exposed on wall - 32mm nominal dia pipes | m | 420.0 | 420.0 | 60.0 | False | None | None | False | None | False | 25200.0 | 0 | 2580672 | 79841 | None | 13.31.6 | Providing & fixing Chorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction Engineer in Charge.Exposed on wall - 50mm nominal dia pipes | m | 820.05 | 820.05 | 90.0 | False | None | None | False | None | False | 73804.5 | 0 | 2580673 | 79841 | None | 13.34 | Providing and placing on terrace, polyethylene water storage tanks as per IS 12701 : 1996 with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flow pipes but without fittings and the base support for tank | l | 9.45 | 9.45 | 2000.0 | False | None | None | False | None | False | 18900.0 | 0 |
|
|
---|