createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1708158751543
version8
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd753000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose02-03-2024 16:00:00
tenderQueryClose22-02-2024 14:30:00
technicalBidOpen04-03-2024 16:00:01
publishedDate17-02-2024 16:33:12
publishedByPostEWHFWD_CE_CEOFF_BNG
publishedByUserKPE16838 - BALEKATTE KUMARASWAMY PAVITHRA
bidValidityPeriod90
noOfCalls1
preBidMeetingDate23-02-2024 11:30:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonTechnical Assistant.
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08029557023
mobileNumber9448653156
tenderSupplierListNone
tenderSchedule
createdTs1708158751574
version16
createdDateNone
modifiedDateNone
tenderNumberEWHFWD/2023-24/BD/WORK_INDENT195
titlePackage-10/2023-24 (1)Upgradation of infrasturture facilities to the TLH and staff Quarters at Putturu in Dakshina Kannada District. (2)Construction of PHC and Staff Quarters at Machhina in Belthangady Taluk, Dakshina Kannada District.
descriptionPackage-10/2023-24 (1)Upgradation of infrasturture facilities to the TLH and staff Quarters at Putturu in Dakshina Kannada District. (2)Construction of PHC and Staff Quarters at Machhina in Belthangady Taluk, Dakshina Kannada District.
categoryWORKS
categoryTextWorks
ecv50167415.60
deptNameEngineering Wing of Health and Family Welfare Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location3521
locationNameEWHFWD Chief Engineer Office Bengaluru
provisionalAmount54000000.0
groupOverheadTotal0.0
fileNumberKHSDRP/AEEMNG/SDP/PCK10/PUTTRMACCHN/2023-24
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17081587520000NoneNoneBuildingsPackage-10/2023-24 1)Upgradation of infrasturture facilities to the TLH and staff Quarters at Putturu in Dakshina Kannada District(Electrical)2400789.7
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
267593783386None2.2.1POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in the existing PVC conduit/ pipe using copper PVC insulated multistrand 2 x 1.5 sq.mm wire without switch on the existing the matel box the other end of the wires shall be terminated with sufficient loose length in a PVC round block , complete for each outlet Short point above 3 mts upto 6mts from tapping point to outlet via switch ---- etc., complete with all leadPoint355.51355.5118.0FalseNoneNoneFalseNoneFalse6399.180
267593883386None2.2.2POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in the existing PVC conduit/ pipe using copper PVC insulated multistrand 2 x 1.5 sq.mm wire without switch on the existing the matel box the other end of the wires shall be terminated with sufficient loose length in a PVC round block , complete for each outlet Medium point above 3 mts upto 6mts from tapping point to outlet via switch ---- etc., complete with all leadPoint500.89500.8922.0FalseNoneNoneFalseNoneFalse11019.580
267593983386None2.2.3POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in the existing PVC conduit/ pipe using copper PVC insulated multistrand 2 x 1.5 sq.mm wire without switch on the existing the matel box the other end of the wires shall be terminated with sufficient loose length in a PVC round block , complete for each outlet Long point above 6 mts upto 10 mts from tapping point to outlet via switch ---- etc., complete with all leadPoint733.49733.4924.0FalseNoneNoneFalseNoneFalse17603.760
267594083386None3.3.2Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 3 way ---- etc., complete with all leadEach163.88163.8822.0FalseNoneNoneFalseNoneFalse3605.360
267594183386None3.3.3Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 4 -5 way ---- etc., complete with all leadEach181.06181.0617.0FalseNoneNoneFalseNoneFalse3078.020
267594283386None3.3.4Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 6 way ---- etc., complete with all leadEach228.64228.6410.0FalseNoneNoneFalseNoneFalse2286.40
267594383386None3.3.5Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.8 way ---- etc., complete with all leadEach289.43289.4314.0FalseNoneNoneFalseNoneFalse4052.020
267594483386None3.3.6Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 10-12 way ---- etc., complete with all leadEach344.94344.9412.0FalseNoneNoneFalseNoneFalse4139.280
267594583386None3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 3 module ---- etc., complete with all leadEach212.78212.7822.0FalseNoneNoneFalseNoneFalse4681.160
267594683386None3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 4 module ---- etc., complete with all leadEach231.28231.2817.0FalseNoneNoneFalseNoneFalse3931.760
267594783386None3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 6 module ---- etc., complete with all leadEach309.25309.2510.0FalseNoneNoneFalseNoneFalse3092.50
267594883386None3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 8 module ---- etc., complete with all leadEach375.33375.3314.0FalseNoneNoneFalseNoneFalse5254.620
267594983386None3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 10-12 module ---- etc., complete with all leadEach454.63454.6312.0FalseNoneNoneFalseNoneFalse5455.560
267595083386None3.6.1Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate 6 amps one way switch ---- etc., complete with all leadEach134.8134.885.0FalseNoneNoneFalseNoneFalse11458.00
267595183386None3.6.3Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate 6 Amps 3 way sockets ---- etc., complete with all leadEach225.99225.9942.0FalseNoneNoneFalseNoneFalse9491.580
267595283386None3.6.7Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate 16 Amps One way switch ---- etc., complete with all leadEach237.89237.8932.0FalseNoneNoneFalseNoneFalse7612.480
267595383386None3.6.4Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate Electronic stepped regulator. ---- etc., complete with all leadEach471.81471.8119.0FalseNoneNoneFalseNoneFalse8964.390
267595483386None3.6.10Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate 6/16 Amps universal sockets ---- etc., complete with all leadEach311.9311.932.0FalseNoneNoneFalseNoneFalse9980.80
267595583386None3.14.6Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate 6A Pendent Holder ---- etc., complete with all leadNos93.8393.8314.0FalseNoneNoneFalseNoneFalse1313.620
267595683386None3.6.9Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate 32A DP Switch ---- etc., complete with all leadNos430.84430.846.0FalseNoneNoneFalseNoneFalse2585.040
267595783386None1.1.1Open Conduit System Supplying heavy gauge PVC conduit pipe . dia . mmthick confirming to IS 2509 with suitable size bends, junctionboxes, adhesive paste etc , and fixing using inverted woodplugs in case of RCC ceiling and RCC wall/ stone structure orrawl plugs in case of brick walls and cement plastering thedamaged portion using heavy gauge saddles at an interval of 700mm using NF screws 19/20 mm dia 2 mm thick ---- etc., complete with all leadMtr91.1991.19550.0FalseNoneNoneFalseNoneFalse50154.50
267595883386None1.1.2Supplying heavy gauge PVC conduit pipe . dia . mmthick confirming to IS 2509 with suitable size bends, junctionboxes, adhesive paste etc , and fixing using inverted woodplugs in case of RCC ceiling and RCC wall/ stone structure orrawl plugs in case of brick walls and cement plastering thedamaged portion using heavy gauge saddles at an interval of 700mm using NF screws 25 mm dia 2 mm thick ---- etc., complete with all leadMtr107.05107.05270.0FalseNoneNoneFalseNoneFalse28903.50
267595983386None1.3.1Supplying heavy gauge PVC Conduit Pipe . dia . mmthick with suitable size bends, metal junction boxes adhesivepaste etc., by groove cutting in the wall and fixing by bracing Uor J hooks and cement plastering upto the wall surface andrun with 18 SWG GI fish wire run throughout the conduitwherever necessary.19/20 mm dia 2 mm thick ---- etc., complete with all leadMtr89.8789.87350.0FalseNoneNoneFalseNoneFalse31454.50
267596083386None2.3.2WIRING FOR Lighting/Power Circuits using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A. 1.5 Sq.mm ---- etc., complete with all leadMtr34.3634.361350.0FalseNoneNoneFalseNoneFalse46386.00
267596183386None2.3.3WIRING FOR Lighting/Power Circuits using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A. 2,5 sq.mm ---- etc., complete with all leadMtr55.5155.51880.0FalseNoneNoneFalseNoneFalse48848.80
267596283386None2.3.4WIRING FOR Lighting/Power Circuits using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A. 4 sq.mm ---- etc., complete with all leadMtr83.2683.26440.0FalseNoneNoneFalseNoneFalse36634.40
267596383386None2.3.5WIRING FOR Lighting/Power Circuits using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A. 6 sq.mm ---- etc., complete with all leadMtr121.59121.59180.0FalseNoneNoneFalseNoneFalse21886.20
267596483386None2.3.6WIRING FOR Lighting/Power Circuits using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A. 10 sq.mm ---- etc., complete with all leadMtr220.71220.71220.0FalseNoneNoneFalseNoneFalse48556.20
267596583386None5.19.10Control System MCB DB Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting. Made out of 14SWG MS enclouser. 16 Way SP & N ---- etc., complete with all leadEach3843.213843.212.0FalseNoneNoneFalseNoneFalse7686.420
267596683386None5.18.1Supplying and fixing miniature circuit breaker, on the existing MCB distribution board using necessary fixing materials and C type curve,indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K & complete wiring as required conforming to IEC 60898. 6-32 Amps SP ---- etc., complete with all leadEach548.46548.4622.0FalseNoneNoneFalseNoneFalse12066.120
267596783386None5.18.5Supplying and fixing miniature circuit breaker, on the existing MCB distribution board using necessary fixing materials and C type curve,indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K & complete wiring as required conforming to IEC 60898. 40 Amps DP ---- etc., complete with all leadEach1400.91400.99.0FalseNoneNoneFalseNoneFalse12608.10
267596883386None5.18.8Supplying and fixing miniature circuit breaker, on the existing MCB distribution board using necessary fixing materials and C type curve,indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K & complete wiring as required conforming to IEC 60898. 40 Amps TPN ---- etc., complete with all leadEach4022.954022.957.0FalseNoneNoneFalseNoneFalse28160.650
267596983386None5.18.9Supplying and fixing miniature circuit breaker, on the existing MCB distribution board using necessary fixing materials and C type curve,indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K & complete wiring as required conforming to IEC 60898. 50-63 A TPN ---- etc., complete with all leadEach4081.14081.19.0FalseNoneNoneFalseNoneFalse36729.90
267597083386None5.46.2Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA 40Amps SP ( office room) ---- etc., complete with all leadEach396.48396.487.0FalseNoneNoneFalseNoneFalse2775.360
267597183386None5.20.1Supplying, fixing and wiring Residual current circuit breaker (RCCB)240/450V upto 300mA sensitivity on existing wood/ panel board.16A-25A 2 pole ---- etc., complete with all leadEach5652.485652.481.0FalseNoneNoneFalseNoneFalse5652.480
267597283386None11.3.2Supplying of .feet - PVC Batten with integrated LED tube.W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20-22 w ---- etc., complete with all leadEach911.9911.936.0FalseNoneNoneFalseNoneFalse32828.40
267597383386None11.4.3LED Down light Supplying of recess mounting non integrated type LEDdown light. W luminaire comprising of pressure decast-extruded aluminium housing, with spring loaded false ceilingclA, LED of Power-COB with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per W, 120degree beam spread,life 25000 burning hours and Compliance to IS10322-IEC60598, LM 79 LM 80. The lamp compartment is enclosedwith anti glare opal diffuser which enhances the lightinglevel. LED s are driven by HF electronic driver integrated in aseparate control gear assembly., with PF 0.95, power lossshould 5% of lamp Wage, short circuit open circuitprotection to be integrated in the circuit, THD less than 20%,Life as per LM 79. The operating input voltage should bebetween 130 to 275 V. BIS Approved and Tested by NABL-CPRI accredited laboratory with 2 years Warrantyagainst any manufacturing defect working under standardelectrical condition 15-18W ---- etc., complete with all leadEach2208.392208.3912.0FalseNoneNoneFalseNoneFalse26500.680
267597483386None11.11.4Supplying and fixing of retrofit type - LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.9W, 6500K ---- etc., complete with all leadEach203.53203.5328.0FalseNoneNoneFalseNoneFalse5698.840
267597583386None11.9.1Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with . W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved Embossing on the die cast housing Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree-Nichia ---- etc., complete with all leadEach8944.598944.594.0FalseNoneNoneFalseNoneFalse35778.360
267597683386None13.7.1Fixing all types and all capacities fluorescent / false ceiling /spot light / CFL fitting indoors on the wall / ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires . Required nos of round blocks and clamps-On wll ceilng/rafter/girders ---- etc., complete with all leadEach161.24161.2460.0FalseNoneNoneFalseNoneFalse9674.40
267597783386None12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C.cutouts and other equipment's on the meter board using 40 mm dia2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should befilled with equal proportion of salt and charcoal 150 mm all-round thepipe to complete depth. The connection from the pipe to the conduitetc., is to be established through GI wire of size as per lSI specification7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nutsetc., the pipe shall have 16 through holes of 12 mm dia ---- etc., complete with all leadNos4638.824638.825.0FalseNoneNoneFalseNoneFalse23194.10
267597883386None6.1Supplying of Exhaust Fan of 1440 RPM of 300mm (12") size with Bracket, blades complete for Light duty suitable to operate on 230V,50Hz, A.C.,supply ---- etc., complete with all leadEach1971.831971.835.0FalseNoneNoneFalseNoneFalse9859.150
267597983386None13.14Fixing one exhaust fan in the nitch already left in the wall with boltsand nuts and 5 A. ceiling rose with sufficient length of 23/0.0076inch PVC insulated twin core wire. ---- etc., complete with all leadEach650.23650.235.0FalseNoneNoneFalseNoneFalse3251.150
267598083386None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 48" Sweep (1200 mm) Regular model ---- etc., complete with all leadEach3943.653943.6524.0FalseNoneNoneFalseNoneFalse94647.60
267598183386None13.11Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clA and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. ---- etc., complete with all leadEach416.3416.324.0FalseNoneNoneFalseNoneFalse9991.20
267598283386None6.5Supplying wall mounting fan suitable to operate at single phase 230v A.C.400mm Sweep ---- etc., complete with all leadEach4244.984244.982.0FalseNoneNoneFalseNoneFalse8489.960
267598383386None63.02,V-6,Page no 28Brass Cable Gland 32mm dia ---- etc., complete with all leadNo125.55125.558.0FalseNoneNoneFalseNoneFalse1004.40
267598483386None59.02 V-6 P No-26Heavy Duty Copper Terminal Long Barrel 35 Sqmm Copper Terminal, Apprx Wt: 17 Gm ---- etc., complete with all leadNo52.8652.8632.0FalseNoneNoneFalseNoneFalse1691.520
267598583386None12.2.2Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote- musical ---- etc., complete with all leadEach573.57573.573.0FalseNoneNoneFalseNoneFalse1720.710
267598683386None5.7.3Supplying & fixing of Porcelain fuse channel with cut out onexisting wooden/panel using necessary nuts, bolts and washers 63 Amps ---- etc., complete with all leadEach529.96529.969.0FalseNoneNoneFalseNoneFalse4769.640
267598783386None5.17.1Supplying and fixing regular MCCB distribution Panelconfirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC62262 with minimum IP43 protection provided withPolyurethane (PUR) gasket, with suitable earthing system, onwall/wood board/flush mounting using required cl A , bolts,nuts, etc., with provision for fixing of suitable type capacityMCCB's as an incomer for 3 phase Double door with necessarybus bar completely wired to use on 440V 3phase 4 wire powdercoated painting etc., complete with a provision for fixing ofsingle/three phase suitable capacity MCB's as outgoingsconfirming to IS/IEC 60898 - 2.-4 way ---- etc., complete with all leadEach13650.8113650.812.0FalseNoneNoneFalseNoneFalse27301.620
267598883386None32.09,V-6 Page No 13Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 35 SQMM ---- etc., complete with all leadKm203608.34203608.340.3FalseNoneNoneFalseNoneFalse61082.5020
267598983386None21.06 V-6Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required. ---- etc., complete with all leadKm41153.341153.30.3FalseNoneNoneFalseNoneFalse12345.990
267599083386None5.42.2LT Panel Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete with all leadSq CM0.570.57250000.0FalseNoneNoneFalseNoneFalse142500.00
267599183386None5.40.2Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250 A 4 x 30 x 10 mm Aluminium Strips ---- etc., complete with all leadMtr4539.74539.77.5FalseNoneNoneFalseNoneFalse34047.750
267599283386None5.40.3Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 400 A 4 x 50 x 10 mm Aluminium Strips ---- etc., complete with all leadMtr5874.515874.515.5FalseNoneNoneFalseNoneFalse32309.8050
267599383386None5.40.4Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 600 A 4 x 75 x 10 mm Aluminium Strips ---- etc., complete with all leadMtr7434.07434.04.0FalseNoneNoneFalseNoneFalse29736.00
267599483386None5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete with all leadMtr403.09403.093.0FalseNoneNoneFalseNoneFalse1209.270
267599583386None5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete with all leadMtr999.13999.132.5FalseNoneNoneFalseNoneFalse2497.8250
267599683386None5.15.17Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. 320-400 A 50 kA ---- etc., complete with all leadEach39794.739794.72.0FalseNoneNoneFalseNoneFalse79589.40
267599783386None5.12.1Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution)" 63 Amps ---- etc., complete with all leadEach9093.939093.938.0FalseNoneNoneFalseNoneFalse72751.440
267599883386None5.12.2Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution)" 100 Amps ---- etc., complete with all leadEach11278.5311278.534.0FalseNoneNoneFalseNoneFalse45114.120
267599983386None5.12.3Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution)" 125 Amps ---- etc., complete with all leadEach16287.416287.43.0FalseNoneNoneFalseNoneFalse48862.20
267600083386None5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., complete with all leadEach12310.712310.71.0FalseNoneNoneFalseNoneFalse12310.70
267600183386None5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete with all leadEach680.62680.626.0FalseNoneNoneFalseNoneFalse4083.720
267600283386None5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc., complete with all leadEach742.74742.746.0FalseNoneNoneFalseNoneFalse4456.440
267600383386None5.13.4Supply and fixing of 4pole power contactor with NO/NCcontacts on existing wood/panel board using necessarybolts, nuts, washers and wiring etc., complete with AC-3Rating and as per IS-13947100 to 125 A ---- etc., complete with all leadEach11927.4411927.442.0FalseNoneNoneFalseNoneFalse23854.880
267600483386None9.2.5Supplying, erecting, testing & commissioning of OFF- LINEUPS system suitable for operation on 230V, 50Hz, A/C supply, with all accessories complete and Excluding batteries and wiring complete.5KVA ---- etc., complete with all leadEach52729.252729.22.0FalseNoneNoneFalseNoneFalse105458.40
267600583386None9.5.6Supplying, installation, testing & commissioning of 12V DC, AHbatteries in poly propylene container for U.P.S. Sealedmaintenance free batteries75/80 AH capacity ---- etc., complete with all leadEach13443.3213443.3212.0FalseNoneNoneFalseNoneFalse161319.840
267600683386None6.8.2Supplying of . TR Invertor type split Air conditioners suitablefor operation on A/C supply single phase 50 Hz 230 V withhermetically sealed inverter compressor with air cooledcondenser, latest R410A / R-32 refrigerant fan motor, start &run capacitors, relay & over load protector internal unit, with one indoor & one outdoor unit The condenser unit will beplaced outside the room avoid noise including standard lengthof suitable size copper tubing covered with nitrile rubberinsulation tube. suitable capacity 3 core sheathed/ PVCcopper cable and a battery operated wireless remote unit.1.5 Ton capacity ---- etc., complete with all leadEach59847.3359847.337.0FalseNoneNoneFalseNoneFalse418931.310
267600783386None6.12Installation charges for split type air conditioner with alliedworks for one indoor and one outdoor unit is to be mounted onsuitable Angle Iron support upto 3.0 Ton split/cassette type A/C. ---- etc., complete with all leadEach4196.084196.087.0FalseNoneNoneFalseNoneFalse29372.560
267600883386None9.1.1Supplying, erecting, testing and commissioning of voltagestabilizer suitable for 170 to 270 v input and load variation fromno load to full load, with over load protection, spikesuppression, operating at 00 C to 400 C. Range etc.,complete ---- etc., complete with all leadEach5279.795279.797.0FalseNoneNoneFalseNoneFalse36958.530
267600983386None5.11.2Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. 100 Amps ---- etc., complete with all leadEach9370.149370.146.0FalseNoneNoneFalseNoneFalse56220.840
267601083386NoneM RManifold room Compressor Motor Rewinding and reinstallation ---- etc., complete with all leadNos26432.026432.01.0FalseNoneNoneFalseNoneFalse26432.00
267601183386None2.2.1POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in the existing PVC conduit/ pipe using copper PVC insulated multistrand 2 x 1.5 sq.mm wire without switch on the existing the matel box the other end of the wires shall be terminated with sufficient loose length in a PVC round block , complete for each outlet Short point above 3 mts upto 6mts from tapping point to outlet via switch ---- etc., complete with all leadPoint355.51355.516.0FalseNoneNoneFalseNoneFalse2133.060
267601283386None2.2.2Supplying and wiring adopting loop system in the existing PVC conduit/ pipe using copper PVC insulated multistrand 2 x 1.5 sq.mm wire without switch on the existing the matel box the other end of the wires shall be terminated with sufficient loose length in a PVC round block , complete for each outlet Medium point above 3 mts upto 6mts from tapping point to outlet via switch ---- etc., complete with all leadPoint500.89500.895.0FalseNoneNoneFalseNoneFalse2504.450
267601383386None2.2.3Supplying and wiring adopting loop system in the existing PVC conduit/ pipe using copper PVC insulated multistrand 2 x 1.5 sq.mm wire without switch on the existing the matel box the other end of the wires shall be terminated with sufficient loose length in a PVC round block , complete for each outlet Long point above 6 mts upto 10 mts from tapping point to outlet via switch ---- etc., complete with all leadPoint733.49733.494.0FalseNoneNoneFalseNoneFalse2933.960
267601483386None3.3.2Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 3 way ---- etc., complete with all leadEach163.88163.883.0FalseNoneNoneFalseNoneFalse491.640
267601583386None3.3.3Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 4 -5 way ---- etc., complete with all leadEach181.06181.064.0FalseNoneNoneFalseNoneFalse724.240
267601683386None3.3.6Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 10-12 way ---- etc., complete with all leadEach344.94344.942.0FalseNoneNoneFalseNoneFalse689.880
267601783386None3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 3 module ---- etc., complete with all leadEach212.78212.783.0FalseNoneNoneFalseNoneFalse638.340
267601883386None3.3.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 4 module ---- etc., complete with all leadEach231.28231.284.0FalseNoneNoneFalseNoneFalse925.120
267601983386None3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 10-12 module ---- etc., complete with all leadEach454.63454.632.0FalseNoneNoneFalseNoneFalse909.260
267602083386None3.6.1Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate 6 amps one way switch ---- etc., complete with all leadEach134.8134.817.0FalseNoneNoneFalseNoneFalse2291.60
267602183386None3.6.3Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate 6 Amps 3 way sockets ---- etc., complete with all leadEach225.99225.997.0FalseNoneNoneFalseNoneFalse1581.930
267602283386None3.6.8Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate 16 Amps One way switch ---- etc., complete with all leadEach237.89237.896.0FalseNoneNoneFalseNoneFalse1427.340
267602383386None3.14.16Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate Electronic stepped regulator. ---- etc., complete with all leadEach371.37371.374.0FalseNoneNoneFalseNoneFalse1485.480
267602483386None3.6.10Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate 6/16 Amps universal sockets ---- etc., complete with all leadEach311.9311.96.0FalseNoneNoneFalseNoneFalse1871.40
267602583386None3.14.6Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate 6A Lamp Holder ---- etc., complete with all leadNos93.8393.8314.0FalseNoneNoneFalseNoneFalse1313.620
267602683386None1.1.1Open Conduit System Supplying heavy gauge PVC conduit pipe . dia . mmthick confirming to IS 2509 with suitable size bends, junctionboxes, adhesive paste etc , and fixing using inverted woodplugs in case of RCC ceiling and RCC wall/ stone structure orrawl plugs in case of brick walls and cement plastering thedamaged portion using heavy gauge saddles at an interval of 700mm using NF screws 19/20 mm dia 2 mm thick ---- etc., complete with all leadMtr91.1991.1924.0FalseNoneNoneFalseNoneFalse2188.560
267602783386None1.1.2Open Conduit System Supplying heavy gauge PVC conduit pipe . dia . mmthick confirming to IS 2509 with suitable size bends, junctionboxes, adhesive paste etc , and fixing using inverted woodplugs in case of RCC ceiling and RCC wall/ stone structure orrawl plugs in case of brick walls and cement plastering thedamaged portion using heavy gauge saddles at an interval of 700mm using NF screws 25 mm dia 2 mm thick ---- etc., complete with all leadMtr107.05107.0534.0FalseNoneNoneFalseNoneFalse3639.70
267602883386None1.3.1Supplying heavy gauge PVC Conduit Pipe . dia . mmthick with suitable size bends, metal junction boxes adhesivepaste etc., by groove cutting in the wall and fixing by bracing Uor J hooks and cement plastering upto the wall surface andrun with 18 SWG GI fish wire run throughout the conduitwherever necessary.19/20 mm dia 2 mm thick ---- etc., complete with all leadMtr89.8789.8727.0FalseNoneNoneFalseNoneFalse2426.490
267602983386None2.3.2WIRING FOR Lighting/Power Circuits using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A. 1.5 Sq.mm ---- etc., complete with all leadMtr34.3634.36195.0FalseNoneNoneFalseNoneFalse6700.20
267603083386None2.3.3WIRING FOR Lighting/Power Circuits using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A. 2,5 sq.mm ---- etc., complete with all leadMtr55.5155.51174.0FalseNoneNoneFalseNoneFalse9658.740
267603183386None2.3.4WIRING FOR Lighting/Power Circuits using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A. 4 sq.mm ---- etc., complete with all leadMtr83.2683.2638.0FalseNoneNoneFalseNoneFalse3163.880
267603283386None2.3.6WIRING FOR Lighting/Power Circuits using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A. 10 sq.mm ---- etc., complete with all leadMtr220.71220.7144.0FalseNoneNoneFalseNoneFalse9711.240
267603383386None5.19.10Control System MCB DB Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting. Made out of 14SWG MS enclouser. 16 Way SP & N ---- etc., complete with all leadEach3843.213843.211.0FalseNoneNoneFalseNoneFalse3843.210
267603483386None5.18.1Supplying and fixing miniature circuit breaker, on the existing MCB distribution board using necessary fixing materials and C type curve,indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K & complete wiring as required conforming to IEC 60898. 6-32 Amps SP ---- etc., complete with all leadEach548.46548.464.0FalseNoneNoneFalseNoneFalse2193.840
267603583386None5.18.5Supplying and fixing miniature circuit breaker, on the existing MCB distribution board using necessary fixing materials and C type curve,indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K & complete wiring as required conforming to IEC 60898. 40 Amps DP ---- etc., complete with all leadEach1400.91400.91.0FalseNoneNoneFalseNoneFalse1400.90
267603683386None5.46.2Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA 40Amps SP ( office room) ---- etc., complete with all leadEach396.48396.481.0FalseNoneNoneFalseNoneFalse396.480
267603783386None5.20.1Supplying, fixing and wiring Residual current circuit breaker (RCCB)240/450V upto 300mA sensitivity on existing wood/ panel board.16A-25A 2 pole ---- etc., complete with all leadEach5652.485652.481.0FalseNoneNoneFalseNoneFalse5652.480
267603883386None11.3.2Supplying of .feet - PVC Batten with integrated LED tube.W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4- 20/22 w ---- etc., complete with all leadEach911.9911.918.0FalseNoneNoneFalseNoneFalse16414.20
267603983386None11.11.4Supplying & fixing of retrofit type - LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRISupplying & fixing of retrofit type - LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy greater than 80 lumen per watt, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should lesser than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.9W, 6500K 70%. efficacy greater than 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should lesser than5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.9W, 6500 ---- etc., complete with all leadEach203.53203.5316.0FalseNoneNoneFalseNoneFalse3256.480
267604083386None13.7.1Fixing all types and all capacities fluorescent / false ceiling /spot light / CFL fitting indoors on the wall / ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires . Required nos of round blocks and clamps-On wll ceilng/rafter/girders ---- etc., complete with all leadEach161.24161.2436.0FalseNoneNoneFalseNoneFalse5804.640
267604183386None6.1Supplying of Exhaust Fan of 1440 RPM of 300mm (12") size with Bracket, blades complete for Light duty suitable to operate on 230V,50Hz, A.C.,supply ---- etc., complete with all leadEach1971.831971.831.0FalseNoneNoneFalseNoneFalse1971.830
267604283386None13.14Fixing one exhaust fan in the nitch already left in the wall with boltsand nuts and 5 A. ceiling rose with sufficient length of 23/0.0076inch PVC insulated twin core wire. ---- etc., complete with all leadEach650.23650.231.0FalseNoneNoneFalseNoneFalse650.230
267604383386None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 48" Sweep (1200 mm) Regular model ---- etc., complete with all leadEach3943.653943.654.0FalseNoneNoneFalseNoneFalse15774.60
267604483386None13.11Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clA and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. ---- etc., complete with all leadEach416.3416.34.0FalseNoneNoneFalseNoneFalse1665.20
17081587520000NoneNoneBuildingsPackage-10/2023-24 1)Upgradation of infrasturture facilities to the TLH and staff Quarters at Putturu in Dakshina Kannada District(Civil)11300071.08
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
267604583387NonePage no 189, item no 19.22.1 of Vol 2 SR 2023-24Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction of Engineer-in-charge.-For thickness of tiles 10 mm to 25 mm ---- etc., complete with all leadSqm63.4463.44651.0FalseNoneNoneFalseNoneFalse41299.440
267604683387NonePage no 26, item no 7.38 of Vol 2 SR 23-24Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. ---- etc., complete with all leadSqm750.67750.671314.0FalseNoneNoneFalseNoneFalse986380.380
267604783387NonePg. No.83, It. No.11.16.3, V-2 of SR 2023-24Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc.complete. Electric resistance or induction butt welded tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge ---- etc., complete with all leadSqm161.24161.2415613.0FalseNoneNoneFalseNoneFalse2517440.120
267604883387NonePage no 26, item no 7.39.1 of Vol 2 SR 23-24Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete ---- etc., complete with all leadMtr596.04596.04149.37FalseNoneNoneFalseNoneFalse89030.49480
267604983387NonePage no 26, item no 7.39.6 of Vol 2 SR 23-24Dialysis Ro plant Gutter Hospital Front Gutter Male Ward Gutter ---- etc., complete with all leadSqm1419.41419.485.98FalseNoneNoneFalseNoneFalse122040.0120
267605083387NonePage no 28, item no 7.41 of Vol 2 SR 23-24Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per m2 including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T”of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures,smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all T sections shall be pre-painted with polyster baked paint, for all heights,as per specifications, drawings and as directed by Engineer-in-Charge. ---- etc., complete with all leadSqm2237.472237.47329.0FalseNoneNoneFalseNoneFalse736127.630
267605183387NonePage no 62, item no 9.21.2 of Vol 2 SR 23-24Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately) ---- etc., complete with all leadSqm1636.141636.14859.25FalseNoneNoneFalseNoneFalse1405853.2950
267605283387NonePage no 60, item no 9.9 of Vol 2 SR 23-24Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. ---- etc., complete with all leadSqm1422.041422.0426.8FalseNoneNoneFalseNoneFalse38110.6720
267605383387NoneVol 2 SR Page no.65, Item no.9.39 23-24Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete with all leadSqm1915.01915.0735.29FalseNoneNoneFalseNoneFalse1408080.350
267605483387NoneVol 2 SR Page no 41,item no 8.2.1 23-24Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm389.87389.87735.29FalseNoneNoneFalseNoneFalse286667.51230
267605583387NoneVol 2 SR Page no 42,item no 8.8 23-24Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) ---- etc., complete with all leadSqm490.31490.3197.39FalseNoneNoneFalseNoneFalse47751.29090
267605683387NonePage no 65, item no 9.40 of Vol 2 SR 23-24Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, griding the edge to half/full round wherever required, labour, curing complete as per specification. ---- etc., complete with all leadSqm1231.731231.736.4FalseNoneNoneFalseNoneFalse7883.0720
267605783387NonePage no 48, item no 8.39 of Vol 2 SR 23-24Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm167.84167.841550.38FalseNoneNoneFalseNoneFalse260215.77920
267605883387NonePage no 46, item no 8.31 of Vol 2 SR 23-24Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge ---- etc., complete with all leadSqm235.24235.241207.0FalseNoneNoneFalseNoneFalse283934.680
267605983387NonePage no 47, item no 8.34.1 of Vol 2 SR 23-24Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm70.0470.04148.41FalseNoneNoneFalseNoneFalse10394.63640
267606083387NonePage no 48, item no 8.40 of Vol 2 SR 23-24Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSet151.98151.98473.73FalseNoneNoneFalseNoneFalse71997.48540
267606183387NonePage no.64,item no.9.32 of Vol 2 SR 2021-22Providing and laying heavy duty cobble stones 75mm thick interlock pavers, using cement and course sand for manufacture of blocks of approved size, shape and colour with a minimum compressive strength of 281 kg per m2 over 50mm thick sand bed ( average thickness ) and compacting with plate vibrator having 3 tons compaction force thereby forcing part of sand underneath to come up in between joints, final compaction of paver surface joints into its final level, including cost of materials, labour and Usage charges of machinery complete as per specifications. ---- etc., complete with all leadSqm1513.231513.23252.0FalseNoneNoneFalseNoneFalse381333.960
267606283387NonePage no.17,item no.6.34 of Vol 2 SR 23-24Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all leadSqm1459.051459.0552.65FalseNoneNoneFalseNoneFalse76818.98250
267606383387NonePage no.112 ,item no.12.96 of Vol 2 SR 2023-24Providing & fixing fiber glass reinforced plastic (FRP) Door frame of cross section 90mm x 45mm having single rebate of 32mm x 15mm to recieve shutter of 30mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyster resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The fram,e shall be covered with fiber glass form all sides. MS stay shall be provided at the bottom to steady the frame. ---- etc., complete with all leadRmtr849.79849.7917.1FalseNoneNoneFalseNoneFalse14531.4090
267606483387NonePage no.112,item no.12.97.1 of Vol 2 SR2023-24Providing & fixing to existing door frames, 30mm thick Glass fibre reinforced plastic (FRP) panelled door shutter of required colour and approved brand and manufacture made with fire retardant grade unsaturated polyster resin, moulded to 3mm thick FRP Laminate for forming hollow railsand styles with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings cast monolithically with 5mm thick FRP Laminate for panels conforming to IS 14856 Including fixing to frames ---- etc., complete with all leadSqm4234.414234.414.73FalseNoneNoneFalseNoneFalse20028.75930
267606583387NonePage no.110,item no.12.88 of Vol 2 SR 23-24Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having a overall size of 60mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm X 58mm with GI reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2-2.5 mm. Maximum possible size 1819mm x 1819mm The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made ---- etc., complete with all leadSqm7123.427123.4256.99FalseNoneNoneFalseNoneFalse405963.70580
267606683387NonePage no.110,item no.12.90 of Vol 2 SR 23-24Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all leadSqm8899.658899.6524.65FalseNoneNoneFalseNoneFalse219376.37250
267606783387NonePage no.109,item no.12.85 of Vol 2 SR 23-24Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all leadSqm7558.237558.232.52FalseNoneNoneFalseNoneFalse19046.73960
267606883387NonePage no 84, item no 11.26.3 of Vol 2 SR 23-24Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-charge. ---- etc., complete with all leadKg241.85241.85357.42FalseNoneNoneFalseNoneFalse86442.0270
267606983387NonePage no 63, item no 9.24 of Vol 2 SRProviding and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent ---- etc., complete with all leadSqm3769.23769.2103.05FalseNoneNoneFalseNoneFalse388416.060
267607083387NoneApproved Data RateSupplying and fixing Precast Concood slabs (Special form of high strength concrete produced in thin sections/ slabs which have weldable edges) of thickness upto 20mm manufactured in various sizes and shapes which are mounted and fixed by welding to one another to form the superstructure of the cabin/checkpost including the interior seating arrangements and racks as per the approved plan and design. The rate includes manufacture, supply, assembly, including fixing and fitting at site, complete., including cost of all materials, labour, HOM of Machinary, complete as per the direction of Engineer in charge of the work. ---- etc., complete with all leadSqm3110.483110.4874.0FalseNoneNoneFalseNoneFalse230175.520
267607183387NonePage No. 6, item no 1.6 of Vol 1 SR 23-24Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work ---- etc., complete with all leadCum639.65639.6512.17FalseNoneNoneFalseNoneFalse7784.54050
267607283387NonePage no 15, item no 2.1.3 of Vol 1 SR 23-24Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum7915.067915.065.0FalseNoneNoneFalseNoneFalse39575.30
267607383387NonePage no 15, item no 2.2.3 of Vol 1 SR 23-24Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum8373.288373.283.0FalseNoneNoneFalseNoneFalse25119.840
267607483387NonePage no 16, item no 2.5.2 of Vol 2 SR 23-24Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately M25 ) Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum9043.529043.524.0FalseNoneNoneFalseNoneFalse36174.080
267607583387NonePage no.18, item no.2.11a of Vol 1 SR 23-24Steel Fabrication Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Buildings ---- etc., complete with all leadTonne118226.56118226.560.75FalseNoneNoneFalseNoneFalse88669.920
267607683387NonePage16, Item no.2.5.2 of Vol 1 SR 23-24Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum9043.719043.712.0FalseNoneNoneFalseNoneFalse18087.420
267607783387NonePage no-125, item no 13.48 of Vol 2 SR 23-24Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes confirming to IS 13592 Type A including Jointing with seal ring Confirming to IS: 5382 Leaving 10mm gap for the thermal expansion i) single socketed pipe 100mm diameter ---- etc., complete with all leadMtr384.59384.5931.0FalseNoneNoneFalseNoneFalse11922.290
267607883387NonePage 9, Item no.5.7 of Vol 2 SR 23-24Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6. ---- etc., complete with all leadSqm8927.418927.4126.33FalseNoneNoneFalseNoneFalse235058.70530
267607983387NonePage no 62, item no 9.20.2 of Vol 2 SR 2023-24Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling/grouting and finishing complete as per direction of Engineer-in-charge Size of Tile 600x600 mm ---- etc., complete with all leadSqm276.21276.211594.54FalseNoneNoneFalseNoneFalse440427.89340
267608083387NonePage no.50,item no.8.51 of Vol 2 SR 23-24Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all leadSqm132.16132.1690.0FalseNoneNoneFalseNoneFalse11894.40
267608183387NonePage no.164 ,item no.19.13.2 of Vol 2 SR 23-24Taking out doors, windows and clerestory window shutters (steel or wood) including stacking to the appropriate disposal area as per direction of Engineer-in-charge.-Of area beyond 3 m² ---- etc., complete with all leadSqm162.56162.5665.03FalseNoneNoneFalseNoneFalse10571.27680
267608283387NonePage no.86,item no.11.34B of Vol 2 SR 23-24Providing and fixing M.S. grills of required pattern in frames of win dows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc ---- etc., complete with all leadKgs241.85241.85907.36FalseNoneNoneFalseNoneFalse219445.0160
17081587520000NoneNoneBuildingsPackage-10/2023-24 1)Upgradation of infrasturture facilities to the TLH and staff Quarters at Putturu in Dakshina Kannada District(Water Supply)278674.9
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
267608383388NoneP.No.122 I.No.13.32.3 of Vol.2 of SR 2023-24Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm Dia ---- etc., complete with all leadm630.4630.435.0FalseNoneNoneFalseNoneFalse22064.00
267608483388NoneP.No.122 I.No. 13.32.4 of Vol.2 of SR 2023-24Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm Dia ---- etc., complete with all leadm736.13736.1330.0FalseNoneNoneFalseNoneFalse22083.90
267608583388NoneP.No.117 I.No.13.2.2 of Vol.2 of SR 2023-24Providing and fixing brass bib cock of approved quality :20 mm nominal bore ---- etc., complete with all leadNos403.09403.098.0FalseNoneNoneFalseNoneFalse3224.720
267608683388NoneP.No.117 I.No.13.4.1 of Vol.2 of SR 2023-24Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) 25 mm nominal bore ---- etc., complete with all leadNos725.56725.564.0FalseNoneNoneFalseNoneFalse2902.240
267608783388NoneP.No.117 I.No.13.4.2 of Vol.2 of SR 2023-24Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) 32 mm nominal bore ---- etc., complete with all leadNos790.32790.322.0FalseNoneNoneFalseNoneFalse1580.640
267608883388NoneP.No.132 I.No.14.7.2 of Vol.2 of SR 2023-24Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever eequire:White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap" ---- etc., complete with all leadEach3384.623384.623.0FalseNoneNoneFalseNoneFalse10153.860
267608983388NoneP.No.136 I.No.14.28.1.2 of Vol.2 of SR 2023-24Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete:Semi rigid pipe:40mm dia ---- etc., complete with all leadEach116.3116.35.0FalseNoneNoneFalseNoneFalse581.50
267609083388NoneP.No.131 I.No.14.3.1 of Vol.2 of SR 2023-24Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete,including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid ---- etc., complete with all leadEach7899.27899.24.0FalseNoneNoneFalseNoneFalse31596.80
267609183388NoneP.No.131 I.No.14.1.1 of Vol.2 of SR 2023-24roviding and fixing water closet squatting pan (Indian type W.C. pan )with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required.White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rest ---- etc., complete with all leadEach6454.696454.696.0FalseNoneNoneFalseNoneFalse38728.140
267609283388NoneP.No.191 I.No.16.9 of Vol.5 of SR 2023-24Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover ---- etc., complete with all leadEach7208.017208.0110.0FalseNoneNoneFalseNoneFalse72080.10
267609383388NoneP.No.113 I.No.10.1.10 of Vol.5 of SR 2023-24Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete for PVC pipes 200mm dia., 6 kg/sqcm & class 3 ---- etc., complete with all leadm1473.581473.5850.0FalseNoneNoneFalseNoneFalse73679.00
17081587520000NoneNoneBuildingsPackage-10/2023-24 (2)Construction of PHC and Staff Quarters at Machhina in Belthangady Taluk, Dakshina Kannada District.(Civil Works)28210086.1
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
267609483389NoneV-3 9 2.5AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer In area of light jungle ---- etc., complete with all lead100 Sqm519.39519.3919.31FalseNoneNoneFalseNoneFalse10029.42090
267609583389NoneV-1 8 1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. ---- etc., complete with all leadCum125.55125.55805.6FalseNoneNoneFalseNoneFalse101143.080
267609683389NoneV-1 8 1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 m. ---- etc., complete with all leadCum134.8134.8985.35FalseNoneNoneFalseNoneFalse132825.180
267609783389NoneV-1 8 1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth ---- etc., complete with all leadCum479.74479.74227.77FalseNoneNoneFalseNoneFalse109270.37980
267609883389NoneV-3 3 1.1ALoading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum ---- etc., complete with all leadCum178.42178.42594.96FalseNoneNoneFalseNoneFalse106152.76320
267609983389NoneV-2 5 4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- etc., complete with all leadSqm155.95155.95784.2FalseNoneNoneFalseNoneFalse122295.990
267610083389NoneV-1 7 1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete with all leadCum351.55351.55996.32FalseNoneNoneFalseNoneFalse350256.2960
267610183389NoneV-1 7 1.8Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- etc., complete with all leadCum626.44626.44541.31FalseNoneNoneFalseNoneFalse339098.23640
267610283389NoneV-1 15 2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates. Including FormWork ---- etc., complete with all leadCum7915.067915.06164.48FalseNoneNoneFalseNoneFalse1301869.06880
267610383389NoneV-1 15 2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including FormWork FOOTINGS ---- etc., complete with all leadCum9043.559043.55139.25FalseNoneNoneFalseNoneFalse1259314.33750
267610483389NoneV-1 15 2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including FormWork PEDESTALS ---- etc., complete with all leadCum9211.029211.0210.2FalseNoneNoneFalseNoneFalse93952.4040
267610583389NoneV-1 16 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork COLUMNS ---- etc., complete with all leadCum15374.315374.348.85FalseNoneNoneFalseNoneFalse751034.5550
267610683389NoneV-1 16 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork PLINTH BEAM ---- etc., complete with all leadCum13565.5613565.5673.08FalseNoneNoneFalseNoneFalse991371.12480
267610783389NoneV-1 16 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork RCC BEAMS ---- etc., complete with all leadCum14469.9314469.9352.75FalseNoneNoneFalseNoneFalse763288.80750
267610883389NoneV-1 16 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork RCC SLAB ---- etc., complete with all leadCum13565.5613565.56116.55FalseNoneNoneFalseNoneFalse1581066.0180
267610983389NoneV-1 16 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork LINTELS ---- etc., complete with all leadCum14469.9314469.9313.8FalseNoneNoneFalseNoneFalse199685.0340
267611083389NoneV-1 16 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work for cill concrete. ---- etc., complete with all leadCum12705.212705.221.97FalseNoneNoneFalseNoneFalse279133.2440
267611183389NoneV-2 43 8.16 aProviding lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja,facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications. ---- etc., complete with all leadSqm1636.141636.1431.83FalseNoneNoneFalseNoneFalse52078.33620
267611283389NoneV-1 18 2.11 aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. ---- etc., complete with all leadTonne118226.37118226.3745.76FalseNoneNoneFalseNoneFalse5410038.69120
267611383389NoneV-2 9 5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- etc., complete with all leadCum8443.78443.751.16FalseNoneNoneFalseNoneFalse431979.6920
267611483389NoneV-2 17 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all leadSqm1731.31731.31474.94FalseNoneNoneFalseNoneFalse2553563.6220
267611583389NoneV-2 17 6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all leadSqm1459.051459.05176.15FalseNoneNoneFalseNoneFalse257011.65750
267611683389NoneV-2 100 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete with all leadCum130593.9130593.91.67FalseNoneNoneFalseNoneFalse218091.8130
267611783389NoneV-2 104 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all leadNos1342.751342.7534.0FalseNoneNoneFalseNoneFalse45653.50
267611883389NoneV-2 218 22.15.2Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mm" ---- etc., complete with all leadNo726.88726.8868.0FalseNoneNoneFalseNoneFalse49427.840
267611983389NoneV-2 219 22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm" ---- etc., complete with all leadNo495.6495.634.0FalseNoneNoneFalseNoneFalse16850.40
267612083389NoneV-2 219 22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm ---- etc., complete with all leadNo198.24198.2468.0FalseNoneNoneFalseNoneFalse13480.320
267612183389NoneV-2 219 22.15.9Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm ---- etc., complete with all leadNo92.5192.51136.0FalseNoneNoneFalseNoneFalse12581.360
267612283389NoneV-2 219 22.15.10Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm ---- etc., complete with all leadNo132.16132.1634.0FalseNoneNoneFalseNoneFalse4493.440
267612383389NoneV-2 105 12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete with all leadNo1390.321390.3234.0FalseNoneNoneFalseNoneFalse47270.880
267612483389NoneV-2 69 10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc., complete with all leadNo79.379.3204.0FalseNoneNoneFalseNoneFalse16177.20
267612583389NoneV-2 205 20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. ---- etc., complete with all leadm68.7268.72183.3FalseNoneNoneFalseNoneFalse12596.3760
267612683389NoneV-2 105 12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-do- 35 mm thick both side Commercial ---- etc., complete with all leadSqm4390.364390.3685.05FalseNoneNoneFalseNoneFalse373400.1180
267612783389NoneV-2 110 12.90Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)" ---- etc., complete with all leadSqm8899.658899.6573.98FalseNoneNoneFalseNoneFalse658396.1070
267612883389NoneV-2 109 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all leadSqm7558.237558.2315.3FalseNoneNoneFalseNoneFalse115640.9190
267612983389NoneV-2 86 11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete with all leadKg222.03222.031874.88FalseNoneNoneFalseNoneFalse416279.60640
267613083389NoneV-2 111 12.93.1Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately)Size 62 x 100mm ---- etc., complete with all leadm927.76927.76110.0FalseNoneNoneFalseNoneFalse102053.60
267613183389NoneV-2 112 12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness ---- etc., complete with all leadSqm4605.784605.7836.96FalseNoneNoneFalseNoneFalse170229.62880
267613283389NoneV-2 105 12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. ---- etc., complete with all leadNo1472.261472.2649.0FalseNoneNoneFalseNoneFalse72140.740
267613383389NoneV-2 41 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) ---- etc., complete with all leadSqm412.34412.341878.67FalseNoneNoneFalseNoneFalse774650.78780
267613483389NoneV-2 43 8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm278.86278.861345.27FalseNoneNoneFalseNoneFalse375141.99220
267613583389NoneV-2 50 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all leadSqm132.16132.163159.37FalseNoneNoneFalseNoneFalse417542.33920
267613683389NoneV-2 42 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside) ---- etc., complete with all leadSqm461.24461.241772.47FalseNoneNoneFalseNoneFalse817534.06280
267613783389NoneV-2 41 8.3.1Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge. ---- etc., complete with all leadSqm467.85467.8590.0FalseNoneNoneFalseNoneFalse42106.50
267613883389NoneV-2 43 8.16.2Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide ---- etc., complete with all leadRmtr50.2250.221248.0FalseNoneNoneFalseNoneFalse62674.560
267613983389NoneV-2 54 8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., complete with all leadRmtr68.7268.721108.03FalseNoneNoneFalseNoneFalse76143.82160
267614083389NoneV-2 61 9.17.2Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm ---- etc., complete with all leadSqm1552.881552.88615.97FalseNoneNoneFalseNoneFalse956527.49360
267614183389NoneV-2 64 9.32Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ---- etc., complete with all leadSqm3412.373412.3729.18FalseNoneNoneFalseNoneFalse99572.95660
267614283389NoneV-2 41 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm389.87389.87239.99FalseNoneNoneFalseNoneFalse93564.90130
267614383389NoneV-2 150 15.7Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) ---- etc., complete with all leadSqm812.78812.7856.14FalseNoneNoneFalseNoneFalse45629.46920
267614483389NoneV-2 60 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. ---- etc., complete with all leadSqm1174.91174.960.48FalseNoneNoneFalseNoneFalse71057.9520
267614583389NoneV-2 65 9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete with all leadSqm1915.01915.0239.99FalseNoneNoneFalseNoneFalse459580.850
267614683389NoneV-2 48 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm167.84167.843159.44FalseNoneNoneFalseNoneFalse530280.40960
267614783389NoneV-2 46 8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm206.17206.171292.47FalseNoneNoneFalseNoneFalse266468.53990
267614883389NoneV-2 47 8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm66.0866.0889.28FalseNoneNoneFalseNoneFalse5899.62240
267614983389NoneV-2 48 8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm151.98151.98178.48FalseNoneNoneFalseNoneFalse27125.39040
267615083389NoneV-2 47 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm70.0470.04204.12FalseNoneNoneFalseNoneFalse14296.56480
267615183389NoneV-2 152 15.12Newly Constructed Roof/Podium with PU Waterproof coating - Above 500 m2-Providing and Applying single component Polyurethane based cold applied seamless waterproofing coating to the RCC surface like Roof & Podium area applied @ 2.4kg/m2 in 3 coats to achieve 1.5mm DFT, including a prime coat of solvent free, medium viscous, epoxy primer @0.2L/m2 and protection with 120gsm Geo-textile over the 7 days cured waterproofing membrane. The Waterproofing material shall have Solids greater than 85%, Tensile strength greater than 2 Mpa as per ASTM D 412, Elongation at break greater than 400% confirms to ASTM C 1305 for crack bridging ability (no cracks up to 3.2mm) Shore A Hardness greater than 55 as per ASTM D 2240, Adhesion to peel after water immersion as per ASTM C 794 at 5.2N. Resistance to root penetration as per UNE CN/ TS 14416. The finished cost to include surface preparation, making coving of 50 mm X 50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 60gsm Geo-textile over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification. ---- etc., complete with all leadSqm1539.661539.66806.2FalseNoneNoneFalseNoneFalse1241273.8920
267615283389NoneV-1 5 1.4.1Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.In all kinds of soils Depth upto 1.5 m ---- etc., complete with all leadCum319.83319.8365.57FalseNoneNoneFalseNoneFalse20971.25310
267615383389NoneV-3 58 8.20G.I Barbed Wire Fencing 1.8 m High- Providing and fixing 1.8 m high GI barbed wire fencing with 2.4 m angle iron posts 50 mm x 50 mm x 6 mm placed every 3 m center to center founded in M15 grade cement concrete, 0.6 metre below ground level, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with 12 horizontal lines and 2 diagonals interwoven with horizontal wires, fixed with GI staples, turn buckles etc complete as per clause 808 ---- etc., complete with all leadm717.63717.63307.0FalseNoneNoneFalseNoneFalse220312.410
267615483389NoneV-2 84 11.25.2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge. ---- etc., complete with all leadKg179.74179.74396.0FalseNoneNoneFalseNoneFalse71177.040
267615583389NoneV-1 15 2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including FormWork RAFT Foundation ---- etc., complete with all leadCum8624.878624.874.7FalseNoneNoneFalseNoneFalse40536.8890
267615683389NoneV-1 15 2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including FormWork WALL ---- etc., complete with all leadCum14235.2214235.2233.26FalseNoneNoneFalseNoneFalse473463.41720
267615783389NoneV-1 15 2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including FormWork SLAB ---- etc., complete with all leadCum12560.4912560.493.77FalseNoneNoneFalseNoneFalse47353.04730
267615883389NoneV-1 8 1.15.2Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Depth exceeding 1.5 m, but not exceeding 3 m ---- etc., complete with all leadCum561.68561.688.56FalseNoneNoneFalseNoneFalse4807.98080
267615983389NoneV-2 152 15.14Providing and Applying two component, water-based food grade epoxy resin coating on inside surface of Potable water tank having anti-algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 300 of US FDA, having mixing Ratio Base: Hardener: Water 1:1:1 to be applied @ 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster, and that Item No. 4 is completed across the entire surface prior to applying the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification. ---- etc., complete with all leadSqm2213.682213.6832.64FalseNoneNoneFalseNoneFalse72254.51520
267616083389NoneV-2 42 8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm491.37491.3765.28FalseNoneNoneFalseNoneFalse32076.63360
267616183389NoneV-2 44 8.21Providing White washing with lime to give an even shade :New work (three coats) with lime of approved quality, including cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm34.3634.3665.28FalseNoneNoneFalseNoneFalse2243.02080
267616283389NoneV-5 221 18.3Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. ---- etc., complete with all leadNos2592.982592.986.0FalseNoneNoneFalseNoneFalse15557.880
267616383389NoneV-2 149 15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/ Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. ---- etc., complete with all leadSqm1079.751079.7556.96FalseNoneNoneFalseNoneFalse61502.560
267616483389NoneV-2 13 6.5Providing Brick work with common burnt clay machine moulded perforated bricks of class designation 5.0 conforming to IS: 2222 in superstructure above plinth level in cement mortar 1:6 (1 cement : 6 coarse sand) With Non modular bricks including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. ---- etc., complete with all leadCum14507.214507.23.25FalseNoneNoneFalseNoneFalse47148.40
267616583389NoneV-2 42 8.6.2Providing 20 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick/ stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge." ---- etc., complete with all leadSqm566.97566.9728.28FalseNoneNoneFalseNoneFalse16033.91160
267616683389NoneV-2 175 17.1Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. ---- etc., complete with all leadCum1324.241324.240.45FalseNoneNoneFalseNoneFalse595.9080
267616783389NoneV-2 175 17.2Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer- in-charge. ---- etc., complete with all leadCum1567.421567.420.45FalseNoneNoneFalseNoneFalse705.3390
267616883389NoneV-2 175 17.3Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. ---- etc., complete with all leadCum1575.351575.350.45FalseNoneNoneFalseNoneFalse708.90750
267616983389NoneV-2 175 17.4Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer- in-charge. ---- etc., complete with all leadCum1769.621769.620.45FalseNoneNoneFalseNoneFalse796.3290
267617083389NoneV-1 11 1.23Providing and Filling in foundation with granite / trap broken metal 100mm. and down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications. ---- etc., complete with all leadCum3544.533544.532.35FalseNoneNoneFalseNoneFalse8329.64550
267617183389NoneV-2 128 13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.110mm nominal dia pipes ---- etc., complete with all leadm508.82508.8210.0FalseNoneNoneFalseNoneFalse5088.20
267617283389NoneV-3 17 3.1Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work ---- etc., complete with all leadCum112.34112.3436.0FalseNoneNoneFalseNoneFalse4044.240
267617383389NoneV-3 17 3.7Compacting original ground supporting embankment-Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction. ---- etc., complete with all leadCum138.77138.7754.0FalseNoneNoneFalseNoneFalse7493.580
267617483389NoneV-1 7 1.8Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- etc., complete with all leadCum626.44626.44108.0FalseNoneNoneFalseNoneFalse67655.520
267617583389NoneV-3 26 4.17Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. ---- etc., complete with all leadCum3163.913163.9154.0FalseNoneNoneFalseNoneFalse170851.140
267617683389NoneV-3 51 6.8.2Providing and laying 80mm thick factory made precast M -30 grade Cement Concrete Paver Block as per IRC SP 63:2018 & IS 15658 for Commercial Traffic Axle load repetitions upto 10MSA & for Residential Streets of approved shape and colour, laid in required pattern and including over 40mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (WMM/WBM Base to be paid separately as per relevant technical specification)" ---- etc., complete with all leadSqm1534.381534.38360.0FalseNoneNoneFalseNoneFalse552376.80
267617783389NoneNon SRThe Tendorer (Agency ) should arrange to obtain (Get) , detailed Architectural drawings and elevations, Structural designs and drawings including Soil exploration & proof checking by IISC /IIT/NIT only as decided by the Department and the same has to be furnished to the Department for approval and providing consultancy for Architectural designs & drawings, elevation, 3D view, MFP design and Drawings, Internal and External Electrical services including electrical infrastructure , interior layout and liaison with other department and approval of pollution control board and allied works etc., and any other drawings related to this project (This item is included in schedule B as a item) and 6 sets of as built drawings should be submitted to the employer. The Consultancy Fees which is included as an item in schedule B shall be paid on prorate basis of the main work or by negotiation with the employer. - etc., complete as per the specification and Engineer-in-charge of work ---- etc., complete with all leadJob347707.63347707.631.0FalseNoneNoneFalseNoneFalse347707.630
17081587520000NoneNoneBuildingsPackage-10/2023-(2)Construction of PHC and Staff Quarters at Machhina in Belthangady Taluk, Dakshina Kannada District.(Water Supply Works)3573705.8
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
267617883390NoneV-2 125 13.50.5Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40mm dia pipes, From wash basin waste lines ---- etc., complete with all leadm401.77401.7768.0FalseNoneNoneFalseNoneFalse27320.360
267617983390NoneV-2 125 13.50.6Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50mm dia pipes, From sink & urinal waste lines ---- etc., complete with all leadm510.14510.1431.0FalseNoneNoneFalseNoneFalse15814.340
267618083390NoneV-2 128 13.64.1GF Toilet "Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage)" 75mm nominal dia pipes ---- etc., complete with all leadm381.94381.94140.0FalseNoneNoneFalseNoneFalse53471.60
267618183390NoneV-2 128 13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage 110mm nominal dia pipes ---- etc., complete with all leadm508.82508.82104.0FalseNoneNoneFalseNoneFalse52917.280
267618283390NoneV-2 128 13.63Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete ---- etc., complete with all leadEach322.47322.4739.0FalseNoneNoneFalseNoneFalse12576.330
267618383390NoneV-2 127 13.59Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete ---- etc., complete with all leadEach290.75290.758.0FalseNoneNoneFalseNoneFalse2326.00
267618483390NoneV-2 125 13.47GF Toilet "Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 75 mm diameter" ---- etc., complete with all leadm260.36260.36180.0FalseNoneNoneFalseNoneFalse46864.80
267618583390NoneV-2 125 13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter ---- etc., complete with all leadm384.59384.5975.0FalseNoneNoneFalseNoneFalse28844.250
267618683390NoneV-2 136 14.31Sanitary and CP fixtures Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. ---- etc., complete with all leadEach1612.351612.3551.0FalseNoneNoneFalseNoneFalse82229.850
267618783390NoneV-2 118 13.9.2GF Toilet Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :150 mm diameter ---- etc., complete with all leadNos368.73368.736.0FalseNoneNoneFalseNoneFalse2212.380
267618883390NoneV-2 135 14.22BGF Toilet "Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge." ---- etc., complete with all leadEach7350.747350.746.0FalseNoneNoneFalseNoneFalse44104.440
267618983390NoneV-2 137 14.40.2GF Toilet "Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour""600 mm long towel rail with total length of 645 mm, width 78 mm and eTFective height of 88 mm, weighing not less than 190 g" ---- etc., complete with all leadEach655.51655.516.0FalseNoneNoneFalseNoneFalse3933.060
267619083390NoneV-2 137 14.38GF Toilet "Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 g" ---- etc., complete with all leadEach191.63191.636.0FalseNoneNoneFalseNoneFalse1149.780
267619183390NoneV-2 119 13.16GF Toilet "Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931" ---- etc., complete with all leadEach819.39819.3962.0FalseNoneNoneFalseNoneFalse50802.180
267619283390NoneV-2 131 14.3.1GF Toilet "Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid" ---- etc., complete with all leadEach7899.27899.215.0FalseNoneNoneFalseNoneFalse118488.00
267619383390NoneV-2 131 14.4.1GF Toilet "Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: One urinal basin with 5 litre white P.V.C. automatic flushing cistern" ---- etc., complete with all leadEach5886.415886.412.0FalseNoneNoneFalseNoneFalse11772.820
267619483390NoneV-2 119 13.15GF Toilet Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. ---- etc., complete with all leadNos958.16958.1621.0FalseNoneNoneFalseNoneFalse20121.360
267619583390NoneV-2 134 14.11.2GF Toilet "Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm" ---- etc., complete with all leadEach6716.376716.376.0FalseNoneNoneFalseNoneFalse40298.220
267619683390NoneV-2 132 14.7.1GF Toilet Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps ---- etc., complete with all leadEach4073.174073.1713.0FalseNoneNoneFalseNoneFalse52951.210
267619783390NoneV-2 140 14.62.aGF Toilet "Providing and fixing Sink cock with swivel spout & wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy" ---- etc., complete with all leadEach2548.042548.046.0FalseNoneNoneFalseNoneFalse15288.240
267619883390NoneV-2 135 14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge. ---- etc., complete with all leadEach1070.51070.524.0FalseNoneNoneFalseNoneFalse25692.00
267619983390NoneV-2 118 13.8.1.1GF Toilet Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore) ---- etc., complete with all leadEach109.69109.6925.0FalseNoneNoneFalseNoneFalse2742.250
267620083390NoneV-2 137 14.37.1GF Toilet "Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, eTFective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 g" ---- etc., complete with all leadEach404.41404.4124.0FalseNoneNoneFalseNoneFalse9705.840
267620183390NoneV-2 137 14.36.1GF Toilet "Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 g ---- etc., complete with all leadEach118.94118.9415.0FalseNoneNoneFalseNoneFalse1784.10
267620283390NoneV-2 117 13.2.1 GF Toilet Providing and fixing brass bib cock of approved quality 15 mm nominal bore ---- etc., complete with all leadNos377.98377.9821.0FalseNoneNoneFalseNoneFalse7937.580
267620383390NoneV2 63 9.29GF Toilet "Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications." ---- etc., complete with all leadSqm5690.815690.815.0FalseNoneNoneFalseNoneFalse28454.050
267620483390NoneV-2 122 13.32.1GF Toilet "Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." GROUND FLOOR 15 mm nominal dia Pipes ---- etc., complete with all leadm408.37408.37131.0FalseNoneNoneFalseNoneFalse53496.470
267620583390NoneV2 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." GROUND FLOOR 20 mm nominal dia Pipes ---- etc., complete with all leadm500.89500.89230.0FalseNoneNoneFalseNoneFalse115204.70
267620683390NoneV2 13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. GROUND FLOOR 25 mm nominal dia pipes ---- etc., complete with all leadm630.4630.4135.0FalseNoneNoneFalseNoneFalse85104.00
267620783390NoneV2 13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. GROUND FLOOR 32 mm nominal dia pipes ---- etc., complete with all leadm736.13736.13115.0FalseNoneNoneFalseNoneFalse84654.950
267620883390NoneV-2 122 13.33.2Shafts & Terrace "Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work" 20 mm nominal dia Pipes ---- etc., complete with all leadm286.79286.7950.0FalseNoneNoneFalseNoneFalse14339.50
267620983390NoneV-2 122 13.33.5Shafts & Terrace "Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work" 40 mm nominal dia Pipes ---- etc., complete with all leadm630.4630.4195.0FalseNoneNoneFalseNoneFalse122928.00
267621083390NoneV-2 122 13.33.6Shafts & Terrace "Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work" 50mm nominal dia Pipes ---- etc., complete with all leadm952.87952.87120.0FalseNoneNoneFalseNoneFalse114344.40
267621183390NoneV-2 117 13.5.2Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :" 25 mm nominal bore ---- etc., complete with all leadNos438.77438.7718.0FalseNoneNoneFalseNoneFalse7897.860
267621283390NoneV-2 117 13.4.2Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :" 32 mm nominal bore ---- etc., complete with all leadNos790.32790.326.0FalseNoneNoneFalseNoneFalse4741.920
267621383390NoneV-2 117 13.4.3Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : ---- etc., complete with all leadNos927.76927.765.0FalseNoneNoneFalseNoneFalse4638.80
267621483390NoneV-2 117 13.4.4Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :" 50 mm nominal bore ---- etc., complete with all leadNos1129.971129.977.0FalseNoneNoneFalseNoneFalse7909.790
267621583390NoneV-2 118 13.6.4.1Providing and fixing gun metal non- return valve of approved quality (screwed end) :" 50 mm nominal bore Horizontal ---- etc., complete with all leadNos1798.71798.74.0FalseNoneNoneFalseNoneFalse7194.80
267621683390NoneV-2 70 10.8Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal parti- tions by cutting a chase of appropriate width with chase cutter and embed- ding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth." ---- etc., complete with all leadSqm3685.943685.942.0FalseNoneNoneFalseNoneFalse7371.880
267621783390NoneV-6 34 ELE 7.3.1Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3 density Rock wool insulation with 22SWG Aluminium cladding." 100 L ---- etc., complete with all leadEach41997.841997.81.0FalseNoneNoneFalseNoneFalse41997.80
267621883390NoneV-2 123 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank." ---- etc., complete with all leadLtr11.8911.897000.0FalseNoneNoneFalseNoneFalse83230.00
267621983390NoneV-2 137 14.37.1Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 g" ---- etc., complete with all leadEach404.41404.419.0FalseNoneNoneFalseNoneFalse3639.690
267622083390NoneV-2 121 13.28.1Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour." 15 mm nominal bore, weighing not less than 32 g ---- etc., complete with all leadNos84.5884.5832.0FalseNoneNoneFalseNoneFalse2706.560
267622183390NoneV-2 133 14.10.1.1Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : (510x1040 mm bowl depth 250 mm) ---- etc., complete with all leadEach7424.757424.753.0FalseNoneNoneFalseNoneFalse22274.250
267622283390NoneV-1 6 1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work." In all kinds of soils Depth upto 1.5 m For Sewer allround For Rainwater allround For Ducts For water supply line from BW to building For Manhole (External Water Supply) ---- etc., complete with all leadCum319.83319.83221.0FalseNoneNoneFalseNoneFalse70682.430
267622383390NoneV-1 7 1.11Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m." (External Water Supply) ---- etc., complete with all leadCum572.25572.25221.0FalseNoneNoneFalseNoneFalse126467.250
267622483390NoneV-5 114 10.3.7Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete. for: EXTERNAL SANITARY WORK"Pipes of SN8 Self Fit - 160mm dia. (External Water Supply) ---- etc., complete with all leadm815.43815.43150.0FalseNoneNoneFalseNoneFalse122314.50
267622583390NoneV-5 115 10.3.8Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete. for: EXTERNAL SANITARY WORK" Pipes of SN8 Self Fit - 200mm dia. (External Water Supply) ---- etc., complete with all leadm1176.221176.22100.0FalseNoneNoneFalseNoneFalse117622.00
267622683390NoneV-5 115 10.3.9Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete. for: EXTERNAL SANITARY WORK" Pipes of SN8 Self Fit - 250mm dia. (External Water Supply) ---- etc., complete with all leadm1807.951807.9550.0FalseNoneNoneFalseNoneFalse90397.50
267622783390NoneV-5 114 10.2.4Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete for EXTERNAL RAIN WATER" Pipes of SN4, 160mm dia. (External Water Supply) ---- etc., complete with all leadm761.24761.24200.0FalseNoneNoneFalseNoneFalse152248.00
267622883390NoneV-5 191 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover." (External Water Supply) ---- etc., complete with all leadEach7208.017208.0120.0FalseNoneNoneFalseNoneFalse144160.20
267622983390NoneV-5 191 16.10Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(CATCH BASIN)"(External Water Supply) ---- etc., complete with all leadEach5598.35598.315.0FalseNoneNoneFalseNoneFalse83974.50
267623083390NoneV-2 124 13.39Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber 150 x 100 mm size P type With Non Modular common burnt clay bricks of designation 3.5 & with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:" (External Water Supply) ---- etc., complete with all leadNos3411.053411.0515.0FalseNoneNoneFalseNoneFalse51165.750
267623183390NoneV-5 194 16.18.6Construction of RCC Machinehole chambers of 1:1.5:3 proportion or approved type Cast-insitu / Pre-cast RCC Machinehole chambers, constructed using form vibrators of standard type, with barricading, danger lighting and using of sight rails and boning rods wherever necessary, shoring and strutting wherever required using Ordinary Port Land Cement, using 1:1.5:3 proportion RCC with 20 mm and down graded jelly, well graded sand and steel of approved quality, 200 mm thick top concrete slab, having wall thickness and raft thickness as in approved drawings and with an offset in raft alround the chamber as in approved drawing, benching concrete with 1:6 slope towards the central drain finished smooth, including fixing and grouting of pipes, including conveying to work spot supply and fixing SFRC Machinehole cover and frame (Heavy duty) conforming to IS:12592 with latest amendments, on a bed of CC 1:2:4 Providing and fixing of minimum 3 mm thick encapsulated plastic footsteps (as per IS 10910) on 12 mm dia. Grade Fe-500 steel bar (as per IS 1786) staggered at 300 mm apart as detailed in Technical specifications, including stone grit beding wherever required, watering, curing, engraving Machinehole number with flow direction on the inner cylindrical surface etc., complete including cost of reinforcement steel and fabrication charges and also cost and conveyance of all materials, labour with all lead and lifts. The Pre-cast RCC Machinehole are for various diamters and depths as stated below and as per detailed drawings, specifications and direction of the Engineer. For 1.2m dia Machinehole: Constructing Pre-cast RCC Machinehole 1.2 m internal dia. ,3.0M depth & SFRC cover & frame" (External Water Supply) ---- etc., complete with all leadEach103729.74103729.742.0FalseNoneNoneFalseNoneFalse207459.480
267623283390NoneV-2 121 13.23.5Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. (50 mm nominal bore, 242mm long, weighing not less than 1240 g) (Enternal Water Supply) ---- etc., complete with all leadNo1776.231776.235.0FalseNoneNoneFalseNoneFalse8881.150
267623383390NoneV-2 122 13.33.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work" 40 mm nominal dia Pipes (External Water Supply ---- etc., complete with all leadm630.4630.475.0FalseNoneNoneFalseNoneFalse47280.00
267623483390NoneV-5 140 12.4Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indic ting the location of the site, recommended depth of casing pipe required seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casin pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging techn al personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of R . 100/- is to be deducted for Dry Borewell towards yield test. tc. complete." (Borewell Water Supply) ---- etc., complete with all leadEach6988.626988.621.0FalseNoneNoneFalseNoneFalse6988.620
267623583390NoneV-5 139 12.1.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 0 to 50 Mtrs (Borewell Water Supply) ---- etc., complete with all leadRmtr488.99488.9950.0FalseNoneNoneFalseNoneFalse24449.50
267623683390NoneV-5 139 12.1.2Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 50 to 100 Mtrs (Borewell Water Supply) ---- etc., complete with all leadRmtr613.22613.2250.0FalseNoneNoneFalseNoneFalse30661.00
267623783390NoneV-5 139 12.1.3Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 100 to 150 Mtrs (Borewell Water Supply) ---- etc., complete with all leadRmtr651.55651.5550.0FalseNoneNoneFalseNoneFalse32577.50
267623883390NoneV-5 139 12.1.4Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 150 to 200 Mtrs (Borewell Waterv Supply) ---- etc., complete with all leadRmtr755.96755.9650.0FalseNoneNoneFalseNoneFalse37798.00
267623983390NoneV-5 139 12.1.5Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 200 to 250 Mtrs (Borewell Water Supply) ---- etc., complete with all leadRmtr886.79886.7950.0FalseNoneNoneFalseNoneFalse44339.50
267624083390NoneV-5 139 12.1.6Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 250 to 300 Mtrs (Borewell Water Supply) ---- etc., complete with all leadRmtr977.98977.9850.0FalseNoneNoneFalseNoneFalse48899.00
267624183390NoneV-5 139 12.1.7Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 300 to 350 Mtrs (Borewell Water Supply) ---- etc., complete with all leadRmtr1147.151147.1550.0FalseNoneNoneFalseNoneFalse57357.50
267624283390NoneV-5 143 12.32Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 nd latest ammendments, electrical resistance welded steel tubes, terial and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixe with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. (Borewell Water Supply) ---- etc., complete with all leadm2554.652554.6535.0FalseNoneNoneFalseNoneFalse89412.750
267624383390NoneV-5 155 13.28Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments. (Borewell Water Supply) ---- etc., complete with all leadRmtr726.88726.88200.0FalseNoneNoneFalseNoneFalse145376.00
267624483390NoneV-5 143 12.33Providing and fixing MS casing collars per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thic ness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments. (Borewell Water Supply) ---- etc., complete with all leadNos198.24198.241.0FalseNoneNoneFalseNoneFalse198.240
267624583390NoneV-5 143 12.34Providing and laying at site of wor MS asing caps as per IS 1239 (part- II) 1982 with all latest amendm nts if any for any dia. The thickness of plate used for covering one e shall be 3mm (minimum). The dimensions of caps and olars shall be strictly as per IS 1239 (Part-II) 1982 with all mendments including cost of material and labour charges for fixing, if a y etc. complete with all lead and lifts and as directed by the Engineer in charge. (Borewell Water Supply) ---- etc., complete with all leadNos216.74216.741.0FalseNoneNoneFalseNoneFalse216.740
267624683390None95 18-19 SR 13.81.3Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete) (Borewell Water Supply) ---- etc., complete with all leadNos277.54277.541.0FalseNoneNoneFalseNoneFalse277.540
267624783390NoneV-5 152 13.13.6Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. For HP etc Complete.5.00 HP - 90 LPM @ 110 m = 15 STG Outlet Dia - 2.00" (Borewell Water Supply) ---- etc., complete with all leadEach42472.2642472.261.0FalseNoneNoneFalseNoneFalse42472.260
267624883390NoneV-5 155 13.23.2Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protectionsuitable for thepumpdescribedabove 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete.3 to 6 HP pumps" (Borewell Water Supply) ---- etc., complete with all leadEach12621.2812621.281.0FalseNoneNoneFalseNoneFalse12621.280
267624983390NoneV-5 155 13.29Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets (Borewell Water Supply) ---- etc., complete with all leadSet2048.482048.481.0FalseNoneNoneFalseNoneFalse2048.480
267625083390NoneV-5 155 13Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. (Borewell Water supply) ---- etc., complete with all leadJob52.8652.86100.0FalseNoneNoneFalseNoneFalse5286.00
267625183390NoneV-5 156 13.32Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. (Borewell Water Supply) ---- etc., complete with all leadJob8590.48590.41.0FalseNoneNoneFalseNoneFalse8590.40
267625283390NoneV-5 156 13.33Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work. (Borewell Water Supply) ---- etc., complete with all leadJob1784.161784.161.0FalseNoneNoneFalseNoneFalse1784.160
267625383390NoneV-6 7 2.6.2Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990.3C x 4 mm2 (Borewell Water Supply) ---- etc., complete with all leadm222.03222.03275.0FalseNoneNoneFalseNoneFalse61058.250
267625483390NoneV-6 20 5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 16SWG (Borewell Water Supply) ---- etc., complete with all leadSq CM0.570.5730000.0FalseNoneNoneFalseNoneFalse17100.00
267625583390NoneV-6 21 5.44.4Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cut-out with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 600mmx600mmx170mm. (Borewell Water Supply) ---- etc., complete with all leadSqm19189.6319189.631.0FalseNoneNoneFalseNoneFalse19189.630
267625683390NoneV-6 14 5.6.6Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws.20" x 20" x 2.5" (Borewell Water Supply) ---- etc., complete with all leadEach431.01431.011.0FalseNoneNoneFalseNoneFalse431.010
267625783390NoneV-6 17 5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A SP (Borewell Water Supply) ---- etc., complete with all leadEach548.46548.461.0FalseNoneNoneFalseNoneFalse548.460
267625883390NoneV-6 57 13.18.1Fixing of . A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling.15A to 63A TPST (Borewell Water Supply) ---- etc., complete with all leadEach367.4367.41.0FalseNoneNoneFalseNoneFalse367.40
267625983390NoneV-6 19 5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries like induction motor. (Borewell Water Supply) ---- etc., complete with all leadKvar634.37634.371.0FalseNoneNoneFalseNoneFalse634.370
267626083390NoneV5 157 13.40.1 Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. (pump room collection sump pumps) (2 HP, Size 65x50 Head 13M, Discharge 462 LPM) (PHC BLOCK) PUMP ---- etc., complete with all leadEach20631.3620631.364.0FalseNoneNoneFalseNoneFalse82525.440
267626183390NoneV5 156 13.32Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. PUMP ---- etc., complete with all leadJob8591.588591.584.0FalseNoneNoneFalseNoneFalse34366.320
17081587520000NoneNoneBuildingsPackage-10/2023-24 Package-10/2023-(2)Construction of PHC and Staff Quarters at Machhina in Belthangady Taluk, Dakshina Kannada District.(Electricals))4404088.02
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
267626283391NoneV-6 5 2.2.1Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch" (Internal Electrification) ---- etc., complete with all leadPoint355.51355.5134.0FalseNoneNoneFalseNoneFalse12087.340
267626383391NoneV-6 5 2.2.2Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch" (Internal Elctrification) ---- etc., complete with all leadPoint500.89500.8951.0FalseNoneNoneFalseNoneFalse25545.390
267626483391NoneV-6 5 2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch" (Internal Electrification) ---- etc., complete with all leadPoint733.49733.4992.0FalseNoneNoneFalseNoneFalse67481.080
267626583391NoneV-6 5 2.2.4Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches" (Internal Electrification) ---- etc., complete with all leadPoint894.72894.728.0FalseNoneNoneFalseNoneFalse7157.760
267626683391NoneV-6 5 2.2.5 Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6Mts up to 10Mtr from tapping point to out let via switches" (Internal Electrification) ---- etc., complete with all leadPoint1307.061307.064.0FalseNoneNoneFalseNoneFalse5228.240
267626783391NoneV-6 8 3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-2Way (Internal Electrification) ---- etc., complete with all leadEach182.38182.3836.0FalseNoneNoneFalseNoneFalse6565.680
267626883391NoneV-6 8 3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3Way (Internal Electrification) ---- etc., complete with all leadEach210.13210.1348.0FalseNoneNoneFalseNoneFalse10086.240
267626983391NoneV-6 8 3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way (Internal Elecrification) ---- etc., complete with all leadEach233.92233.9228.0FalseNoneNoneFalseNoneFalse6549.760
267627083391NoneV-6 8 3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way (Internal Electrification) ---- etc., complete with all leadEach290.75290.7511.0FalseNoneNoneFalseNoneFalse3198.250
267627183391NoneV-6 8 3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way (Internal Electrification) ---- etc., complete with all leadEach344.94344.9426.0FalseNoneNoneFalseNoneFalse8968.440
267627283391NoneV-6 8 3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way (Internal Electrification) ---- etc., complete with all leadEach421.59421.5939.0FalseNoneNoneFalseNoneFalse16442.010
267627383391NoneV-6 8 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module (Internal Electrification) ---- etc., complete with all leadEach181.06181.0636.0FalseNoneNoneFalseNoneFalse6518.160
267627483391NoneV-6 8 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 Module (Internal Electrification) ---- etc., complete with all leadEach212.78212.7848.0FalseNoneNoneFalseNoneFalse10213.440
267627583391NoneV-6 8 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module (Internal Electrification) ---- etc., complete with all leadEach231.28231.2828.0FalseNoneNoneFalseNoneFalse6475.840
267627683391NoneV-6 8 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module (Internal Electrification) ---- etc., complete with all leadEach309.25309.2511.0FalseNoneNoneFalseNoneFalse3401.750
267627783391NoneV-6 8 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module (Internal Electrification) ---- etc., complete with all leadEach375.33375.3326.0FalseNoneNoneFalseNoneFalse9758.580
267627883391NoneV-6 8 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module (Internal Electrification) ---- etc., complete with all leadEach454.63454.6339.0FalseNoneNoneFalseNoneFalse17730.570
267627983391NoneV-6 9 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch (Internal Electrification) ---- etc., complete with all leadEach134.8134.8294.0FalseNoneNoneFalseNoneFalse39631.20
267628083391NoneV-6 9 3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way Switch (Internal Certification) ---- etc., complete with all leadEach219.39219.392.0FalseNoneNoneFalseNoneFalse438.780
267628183391NoneV-6 9 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket (Internal Electrification) ---- etc., complete with all leadEach225.99225.99105.0FalseNoneNoneFalseNoneFalse23728.950
267628283391NoneV-6 9 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. (Internal Electrification) ---- etc., complete with all leadEach471.81471.8131.0FalseNoneNoneFalseNoneFalse14626.110
267628383391NoneV-6 9 3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch (Internal Electrifiaction) ---- etc., complete with all leadEach430.84430.8423.0FalseNoneNoneFalseNoneFalse9909.320
267628483391NoneV-6 9 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket (Internal Electrification) ---- etc., complete with all leadEach311.9311.933.0FalseNoneNoneFalseNoneFalse10292.70
267628583391NoneV-6 9 3.6.7Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch Internal Electrification) ---- etc., complete with all leadEach237.89237.8910.0FalseNoneNoneFalseNoneFalse2378.90
267628683391NoneV-6 4 1.13Supplyin and Fixing Metal Fan Box with Round Hook. (Internal Electrification) ---- etc., complete with all leadNo154.63154.6331.0FalseNoneNoneFalseNoneFalse4793.530
267628783391NoneV-6 2 1.2.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 19/20mm dia 2mm thick (Internal Electrification) ---- etc., complete with all leadMtr87.2387.231210.0FalseNoneNoneFalseNoneFalse105548.30
267628883391NoneV-6 2 1.2.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick (Internal Electrification) ---- etc., complete with all leadMtr103.08103.081780.0FalseNoneNoneFalseNoneFalse183482.40
267628983391NoneV-6 2 1.2.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 32mm dia 2.5mm thick (Internal Electrification) ---- etc., complete with all leadMtr136.12136.12250.0FalseNoneNoneFalseNoneFalse34030.00
267629083391NoneV-6 2 1.3.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick (Internal Electrification) ---- etc., complete with all leadMtr89.8789.87605.0FalseNoneNoneFalseNoneFalse54371.350
267629183391NoneV-6 2 1.3.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thick (Internal Electrification) ---- etc., complete with all leadMtr104.41104.41740.0FalseNoneNoneFalseNoneFalse77263.40
267629283391NoneV-6 2 1.3.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick (Internal Electrification) ---- etc., complete with all leadMtr130.84130.84150.0FalseNoneNoneFalseNoneFalse19626.00
267629383391NoneV-6 5 2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm" (Internal Electrification) ---- etc., complete with all leadMtr34.3634.36640.0FalseNoneNoneFalseNoneFalse21990.40
267629483391NoneV-6 5 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm" (Internal Electrification) ---- etc., complete with all leadMtr55.5155.512055.0FalseNoneNoneFalseNoneFalse114073.050
267629583391NoneV-6 5 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmm" (Internal Electrification) ---- etc., complete with all leadMtr83.2683.261080.0FalseNoneNoneFalseNoneFalse89920.80
267629683391NoneV-6 5 2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmm" (Internal Electrification) ---- etc., complete with all leadMtr121.59121.59610.0FalseNoneNoneFalseNoneFalse74169.90
267629783391NoneV-6 PWD SR 18 5.19.9Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 12 Way SP & N (Internal Electrification) ---- etc., complete with all leadEach3078.013078.014.0FalseNoneNoneFalseNoneFalse12312.040
267629883391NoneV-6 18 5.19.11Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 4 Way TP & N (Internal Electrification) ---- etc., complete with all leadEach5336.625336.622.0FalseNoneNoneFalseNoneFalse10673.240
267629983391NoneV-6 18 5.19.12Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 6 Way TP & N (Internal Electrification) ---- etc., complete with all leadEach6528.76528.71.0FalseNoneNoneFalseNoneFalse6528.70
267630083391NoneV-6 17 5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP (Internal Electrification) ---- etc., complete with all leadEach548.46548.4682.0FalseNoneNoneFalseNoneFalse44973.720
267630183391NoneV-6 17 5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40Amps TPN (Internal Electrification) ---- etc., complete with all leadEach4022.954022.952.0FalseNoneNoneFalseNoneFalse8045.90
267630283391NoneV-6 18 5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN (Internal Electrification) ---- etc., complete with all leadEach4081.14081.11.0FalseNoneNoneFalseNoneFalse4081.10
267630383391NoneV-6 18 5.20.8Supplying, fixing and wiring Residual current Circuit Breaker [RCCB] 240/450V up to 300mA sensitivity on existing wood/panel board 32-40 Amps 4 pole (internal Electrification) ---- etc., complete with all leadEach6802.286802.283.0FalseNoneNoneFalseNoneFalse20406.840
267630483391NoneV-6 PWD SR 18 5.20.1Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board 16-25 Amps 2 pole (Internal Electrification) ---- etc., complete with all leadEach5652.485652.484.0FalseNoneNoneFalseNoneFalse22609.920
267630583391NoneV-6 13 32.051.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 4 core 16 sqmm (Internal Electrification) ---- etc., complete with all leadKm116853.23116853.230.1FalseNoneNoneFalseNoneFalse11685.3230
267630683391NoneV-6 13 32.091.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 35 sqmm (Internal Electrification) ---- etc., complete with all leadKm203608.34203608.340.05FalseNoneNoneFalseNoneFalse10180.4170
267630783391NoneV-6 13 32.131.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 70 sqmm (Internal Electrification) ---- etc., complete with all leadKm420152.5420152.50.1FalseNoneNoneFalseNoneFalse42015.250
267630883391NoneV-6 52 31.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm (Internal Electrification) ---- etc., complete with all leadKm27602.9427602.940.35FalseNoneNoneFalseNoneFalse9661.0290
267630983391NoneV-6 52 31.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 sqmm to 95 sqmm (Internal Electrification) ---- etc., complete with all leadKm41153.341153.30.2FalseNoneNoneFalseNoneFalse8230.660
267631083391NonePWD SR 19-20 6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia (Internal Electrification) ---- etc., complete with all leadEach154.63154.636.0FalseNoneNoneFalseNoneFalse927.780
267631183391NonePWD SR 19-20 6.11.6Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 63mm dia (Internal Electrification) ---- etc., complete with all leadEach512.78512.7810.0FalseNoneNoneFalseNoneFalse5127.80
267631283391NonePWD SR 19-20 6.17.6Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 10 sqmm (Internal Electrification) ---- etc., complete with all leadEach16.4416.4412.0FalseNoneNoneFalseNoneFalse197.280
267631383391NonePWD SR 19-20 6.17.8Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 35 sqmm Long Barrel (Internal Electrification) ---- etc., complete with all leadEach42.2942.2916.0FalseNoneNoneFalseNoneFalse676.640
267631483391NonePWD SR 19-20 6.17.10Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 70 sqmm Long Barrel (Internal Electrification) ---- etc., complete with all leadEach158.59158.5916.0FalseNoneNoneFalseNoneFalse2537.440
267631583391NoneV-6 54 12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia (Internal Electrification) ---- etc., complete with all leadNo4638.824638.829.0FalseNoneNoneFalseNoneFalse41749.380
267631683391NoneV-6 54 12.58.2Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip (Internal Electrification) ---- etc., complete with all leadMtr108.37108.37100.0FalseNoneNoneFalseNoneFalse10837.00
267631783391NoneV-6 55 12.58.6Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip 600x600x3mm GI plate (Internal Electrification) ---- etc., complete with all leadEach1156.41156.46.0FalseNoneNoneFalseNoneFalse6938.40
267631883391NoneV-6 44 11.5.2Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor Greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12W (Internal Electrification) ---- etc., complete with all leadEach1169.621169.6219.0FalseNoneNoneFalseNoneFalse22222.780
267631983391NoneV-6 44 11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor Greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W (Internal Electrification) ---- etc., complete with all leadEach1749.81749.85.0FalseNoneNoneFalseNoneFalse8749.00
267632083391NoneV-6 43 11.3.2Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w (Internal Electrification) ---- etc., complete with all leadEach911.9911.963.0FalseNoneNoneFalseNoneFalse57449.70
267632183391NoneV-6 47 11.11.3Supplying & fixing of retrofit type - LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greter than 70%. efficacy greter than 80 lumen per watt, life greter than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greter than 0.95, power loss should lesser than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K (Internal Electrification) ---- etc., complete with all leadEach196.92196.9221.0FalseNoneNoneFalseNoneFalse4135.320
267632283391NoneV-6 47 11.11.5Supplying & fixing of retrofit type - LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 80 lumen per watt, lifegreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should lesser than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 W, 6500K (Internal Electrification) ---- etc., complete with all leadEach355.51355.5117.0FalseNoneNoneFalseNoneFalse6043.670
267632383391NoneV-6 45 11.6.3Supplying of recess mounting non integral type .LED . W luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded fase ceiling clamps, Power LEDs with CCT 6500 degree K, CRI greater than 70%. efficacy greater than100 lumen per watt, 120degree beam spread, lifegreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF greater than 0.95, power loss should lesser than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, , THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2'x2' - 34 -36watt (Internal Electrification) ---- etc., complete with all leadEach6017.246017.248.0FalseNoneNoneFalseNoneFalse48137.920
267632483391NoneV-6 46 11.8.2Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greaterthan 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greaterthan IK08. Power Factor greaterthan 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency greaterthan130lm/w, nominal CRI greaterthan75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40watts (Internal Electrification) ---- etc., complete with all leadNo5318.125318.122.0FalseNoneNoneFalseNoneFalse10636.240
267632583391NoneV-6 30 6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. (Internal Electrification) ---- etc., complete with all leadEach1971.831971.8318.0FalseNoneNoneFalseNoneFalse35492.940
267632683391NoneV-6 30 6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 48" Sweep 5 Star (1200 mm) (Internal Electrification) ---- etc., complete with all leadEach3537.923537.9231.0FalseNoneNoneFalseNoneFalse109675.520
267632783391NoneV-6 52 12.46Supplying & Fixing of 70-150 Watts lamp holder 2 Pin (Internal Electrification) ---- etc., complete with all leadEach83.2683.2621.0FalseNoneNoneFalseNoneFalse1748.460
267632883391NoneV-6 56 13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders (Internal Electrification) ---- etc., complete with all leadEach161.24161.2495.0FalseNoneNoneFalseNoneFalse15317.80
267632983391NoneV-6 57 13.11Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired." (Internal Electrification) ---- etc., complete with all leadEach416.3416.331.0FalseNoneNoneFalseNoneFalse12905.30
267633083391NoneV-6 57 13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. (Internal Electrification) ---- etc., complete with all leadEach934.37934.3718.0FalseNoneNoneFalseNoneFalse16818.660
267633183391NoneV-6 56 13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length (Internal Electrification) ---- etc., complete with all leadEach1930.861930.865.0FalseNoneNoneFalseNoneFalse9654.30
267633283391NoneV-6 56 13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. Internal Electrifications ---- etc., complete with all leadEach214.1214.15.0FalseNoneNoneFalseNoneFalse1070.50
267633383391NoneV-6 20 5.42.2MAIN LT PANEL Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG (Internal Electrification) ---- etc., complete with all leadSq CM0.570.5796000.0FalseNoneNoneFalseNoneFalse54720.00
267633483391NoneV-6 20 5.40.2Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips (Internal Electrification) ---- etc., complete with all leadMtr4539.74539.75.0FalseNoneNoneFalseNoneFalse22698.50
267633583391NoneV-6 20 5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm (Internal Electrification) ---- etc., complete with all leadMtr403.09403.0910.0FalseNoneNoneFalseNoneFalse4030.90
267633683391NoneV-6 20 5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel (Internal Electrification) ---- etc., complete with all leadMtr999.13999.1310.0FalseNoneNoneFalseNoneFalse9991.30
267633783391NoneV-6 16 5.14.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE 100Amps 25kA (Internal Electrification) ---- etc., complete with all leadEach11216.4211216.421.0FalseNoneNoneFalseNoneFalse11216.420
267633883391NoneV-6 18 5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN (Internal Electrification) ---- etc., complete with all leadEach4081.14081.110.0FalseNoneNoneFalseNoneFalse40811.00
267633983391NoneV-6 19 5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy (Internal Elcetrification) ---- etc., complete with all leadEach12310.712310.71.0FalseNoneNoneFalseNoneFalse12310.70
267634083391NoneV-6 19 5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C (Internal Electrification) ---- etc., complete with all leadEach680.62680.623.0FalseNoneNoneFalseNoneFalse2041.860
267634183391NoneV-6 19 5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound (Internal Electrifications) ---- etc., complete with all leadEach742.74742.743.0FalseNoneNoneFalseNoneFalse2228.220
267634283391NoneV-6 19 5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery (Internal Electrifications) ---- etc., complete with all leadKvar634.37634.3715.0FalseNoneNoneFalseNoneFalse9515.550
267634383391NoneV-6 16 5.14.1Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 Amps Internal Electrifications ---- etc., complete with all leadEach2920.742920.742.0FalseNoneNoneFalseNoneFalse5841.480
267634483391NoneV-6 9 3.6.12TELEPHONE & NETWORKING RJ45/ I.O. outlet Cat 6 (Internal Electrifications) ---- etc., complete with all leadEach445.38445.3810.0FalseNoneNoneFalseNoneFalse4453.80
267634583391NoneV-6 9 3.6.11Telephone socket (Internal Electrification) ---- etc., complete with all leadEach206.17206.1710.0FalseNoneNoneFalseNoneFalse2061.70
267634683391NoneV-6 36 8.1Supplying and drawing UTP-CAT 6E LAN cable. (Internal Electrification) ---- etc., complete with all leadMtr50.2250.22300.0FalseNoneNoneFalseNoneFalse15066.00
267634783391NoneV-6 36 8.10.1Supplying & Fixing of I/O Socket with back box Single I/O (Internal Electrifications) ---- etc., complete with all leadEach647.58647.5810.0FalseNoneNoneFalseNoneFalse6475.80
267634883391NoneV-6 36 8.4.3Supplying & Fixing of switch mounting rack with power manager & Cable manager as per standard specification 9U with 450mm depth (Internal Electrifications) ---- etc., complete with all leadEach11201.8811201.881.0FalseNoneNoneFalseNoneFalse11201.880
267634983391NoneV-6 36 8.9.11Supplying fixing of Network Switches. 16 port 10/100/1000 Switch (Internal Electrifications) ---- etc., complete with all leadEach8511.18511.11.0FalseNoneNoneFalseNoneFalse8511.10
267635083391NoneV-6 37 8.11.1Supplying & fixing of .mtrs. Cat 6Patch Cable. 2Mtr (Internal Electrifications) ---- etc., complete with all leadEach339.65339.6510.0FalseNoneNoneFalseNoneFalse3396.50
267635183391NoneV-6 37 8.12.3Supplying & Fixing of Patch panel for Lan Cabling. 16 Port 10/100 patch panel (Internal Electrifications) ---- etc., complete with all leadEach4030.884030.881.0FalseNoneNoneFalseNoneFalse4030.880
267635283391NoneV-6 36 8.2.2Supplying and drawing PVC flexible 2 pair telepone unarmoured tinned copper cable. (Internal Electrification) ---- etc., complete with all leadMtr27.7527.75300.0FalseNoneNoneFalseNoneFalse8325.00
267635383391NoneV-6 37 8.13.2Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination. 20 Pair (Internal Electrification) ---- etc., complete with all leadEach506.17506.171.0FalseNoneNoneFalseNoneFalse506.170
267635483391NoneV-6 9 3.6.11TV/Telephone socket (Internal Electrification) ---- etc., complete with all leadEach206.17206.178.0FalseNoneNoneFalseNoneFalse1649.360
267635583391NoneV-6 48 12.2.1Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell (Internal Electrification ---- etc., complete with all leadEach325.11325.113.0FalseNoneNoneFalseNoneFalse975.330
267635683391NoneV-6 13 32.021.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 2 core 10 sqmm (Internal Electrification) ---- etc., complete with all leadKm104713.01104713.010.3FalseNoneNoneFalseNoneFalse31413.9030
267635783391NonePWD SR 19-20 6.3Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.,(75/23) 8 SWG-GI Wire (Internal Electrification) ---- etc., complete with all leadMtr16.4416.4445.0FalseNoneNoneFalseNoneFalse739.80
267635883391NoneV-6 50 12.27Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power Supply" (Internal Electrification) ---- etc., complete with all leadEach68.7268.726.0FalseNoneNoneFalseNoneFalse412.320
267635983391NoneV-6 46 11.8.1Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage - Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency greater than130lm/w, nominal CRI greater than 75. Luminaire manufacturer should have in-house facility accredited by NABL-CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark - name shall be Engraved - Embossing on the die cast housing- Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 25watts (Internal Electrification)- ---- etc., complete with all leadNo3204.883204.883.0FalseNoneNoneFalseNoneFalse9614.640
267636083391NoneV-614 5.7.2Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers32Amps (Internal Electrification) ---- etc., complete with all leadEach318.51318.514.0FalseNoneNoneFalseNoneFalse1274.040
267636183391NoneV-6 19 5.30Supplying, fixing and wiring electronic 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter (Internal Electrification) ---- etc., complete with all leadEach1823.811823.813.0FalseNoneNoneFalseNoneFalse5471.430
267636283391NoneV-6 34 7.1.3Supplying .litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate .2KW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting.25Litres (Internal Electrification) ---- etc., complete with all leadEach13535.8313535.833.0FalseNoneNoneFalseNoneFalse40607.490
267636383391NoneV-6 47 11.11.7Supplying & fixing of retrofit type - LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 80 lumen per watt, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should lesser than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18 W, 6500K (Internal Electrification) ---- etc., complete with all leadEach563.0563.011.0FalseNoneNoneFalseNoneFalse6193.00
267636483391NoneV-6 38 9.3.3Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 5 kVA ON LINE UPS (UPS) ---- etc., complete with all leadEach90374.9790374.971.0FalseNoneNoneFalseNoneFalse90374.970
267636583391NoneV-6 38 9.5.3Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 26 AH capacity (UPS) ---- etc., complete with all leadEach4772.34772.316.0FalseNoneNoneFalseNoneFalse76356.80
267636683391NoneV-6 3 1.01DP STRUCTURE Supply RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 (External Electrification) ---- etc., complete with all leadNos.9351.649351.642.0FalseNoneNoneFalseNoneFalse18703.280
267636783391NoneV-6 44 2.02Erection of RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 (External Electrification) ---- etc., complete with all leadSet1470.941470.942.0FalseNoneNoneFalseNoneFalse2941.880
267636883391NoneV-6 5 6.05Supply of 11 kV, 45 KN Polymeric Insulator (External Electrification) ---- etc., complete with all leadNo114.98114.986.0FalseNoneNoneFalseNoneFalse689.880
267636983391NoneV-6 48 13.12Erection of 11 kV, 45 KN Polymeric Insulator (External Electrification) ---- etc., complete with all leadNo63.4463.446.0FalseNoneNoneFalseNoneFalse380.640
267637083391NoneV-6 4 2.16Supply of Spiral Earth Electrode (External Electrification) ---- etc., complete with all leadNo315.86315.862.0FalseNoneNoneFalseNoneFalse631.720
267637183391NoneV-6 4 2.16Erection of Spiral Earth Electrode (External Electrification) ---- etc., complete with all leadNo122.91122.912.0FalseNoneNoneFalseNoneFalse245.820
267637283391NoneV-6 32 68.17Supply and fixing of Caution/Danger Board (External Electrification) ---- etc., complete with all leadNo198.24198.241.0FalseNoneNoneFalseNoneFalse198.240
267637383391NoneV-6 4 4.02Supply of Anti Climbing Device (12 Mtr GI Barbed Wire (External Electrification) ---- etc., complete with all leadEach117.62117.622.0FalseNoneNoneFalseNoneFalse235.240
267637483391NoneV-6 45 5.09Erection of Anti Climbing Device (12 Mtr GI Barbed Wire (External Electrification) ---- etc., complete with all leadEach55.5155.512.0FalseNoneNoneFalseNoneFalse111.020
267637583391NoneV-6 11 24.05Supply and fixing of 11 kV, 400 Amps Double Break GOS (External Electrification) ---- etc., complete with all leadSet28097.2228097.221.0FalseNoneNoneFalseNoneFalse28097.220
267637683391NoneV-6 11 24.07Supply and fixing of H-Frame for mounting GOS (External Electrification) ---- etc., complete with all leadNo8023.438023.431.0FalseNoneNoneFalseNoneFalse8023.430
267637783391NoneV-6 12 25.01Supply of DOLO Cut Out (External Electrification) ---- etc., complete with all leadSet of 3 Nos7764.47764.41.0FalseNoneNoneFalseNoneFalse7764.40
267637883391NoneV-6 12 13.01Erection of DOLO Cut Out (External Electrification) ---- etc., complete with all leadSet of 3 Nos313.22313.221.0FalseNoneNoneFalseNoneFalse313.220
267637983391NoneV-6 3 1.01Supply RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 (External Electrification) ---- etc., complete with all leadSet9351.649351.646.0FalseNoneNoneFalseNoneFalse56109.840
267638083391NoneV-6 44 2.02Erection of RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 (External Electrification) ---- etc., complete with all leadNos1470.941470.946.0FalseNoneNoneFalseNoneFalse8825.640
267638183391NoneV-6 3 2.02Supply of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL" (External Elecrtification) ---- etc., complete with all leadNos643.62643.626.0FalseNoneNoneFalseNoneFalse3861.720
267638283391NoneV-6 3 2.02Erection of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL" (External Electrification) ---- etc., complete with all leadNos339.65339.656.0FalseNoneNoneFalseNoneFalse2037.90
267638383391NoneV-6 5 6.06Supply and fixing of 11 kV, 5 KN Polymeric Pin Insulator (24 mm Dia FRP Rod) " (External Electrification) ---- etc., complete with all leadNos270.93270.9318.0FalseNoneNoneFalseNoneFalse4876.740
267638483391NoneV-6 5 6.10Supply and fixing of 11 kV, 45 KN Polymeric Insulator (External Electrification) ---- etc., complete with all leadNos.245.82245.8218.0FalseNoneNoneFalseNoneFalse4424.760
267638583391NoneV-6 48 13.12Erection of 11 kV, 45 KN Polymeric Insulator (External Electrification) ---- etc., complete with all leadNos63.4463.4418.0FalseNoneNoneFalseNoneFalse1141.920
267638683391NoneV-6 5 6.08Supply and fixing of 15 Strain Insulator (External Electrification) ---- etc., complete with all leadNos77.9777.974.0FalseNoneNoneFalseNoneFalse311.880
267638783391NoneV-6 5 7.02ACSR Conductor as per IS-398 (Part - 2/1996) Rabbit ACSR (6/3.35 mm Al + 1/3.35 mm St), Std Wt: 214 Kg/KM (External Electrification) ---- etc., complete with all leadKm61102.8561102.851.0FalseNoneNoneFalseNoneFalse61102.850
267638883391NoneV-6 46 6.02Erection of Rabbit ACSR Conductor (External Electrification) ---- etc., complete with all leadKm5763.55763.51.0FalseNoneNoneFalseNoneFalse5763.50
267638983391NoneV-6 6 10.01Supply and fixing of PG Clamps for Rabbit Conductor (External Electrification) ---- etc., complete with all leadNos185.02185.0215.0FalseNoneNoneFalseNoneFalse2775.30
267639083391NoneV-6 4 2.16Supply of Spiral Earth Electrode (External Electrification) ---- etc., complete with all leadNo315.86315.869.0FalseNoneNoneFalseNoneFalse2842.740
267639183391NoneV-6 4 2.16Erection of Spiral Earth Electrode (External Electrification) ---- etc., complete with all leadNo122.91122.919.0FalseNoneNoneFalseNoneFalse1106.190
267639283391NoneV-6 32 68.17Supply and fixing of Caution/Danger Board (External Electrification) ---- etc., complete with all leadNo198.24198.245.0FalseNoneNoneFalseNoneFalse991.20
267639383391NoneV-6 4 4.02Supply of Anti Climbing Device (12 Mtr GI Barbed Wire (External Electrification) ---- etc., complete with all leadEach117.62117.626.0FalseNoneNoneFalseNoneFalse705.720
267639483391NoneV-6 45 5.09Erection of Anti Climbing Device (12 Mtr GI Barbed Wire (External Electrification) ---- etc., complete with all leadEach55.5155.516.0FalseNoneNoneFalseNoneFalse333.060
267639583391NoneV-6 8 13.07Supply, erection, testing and commissioning of 63 KVA 5Star rated Aluminium wound Distribution Transformer 11KV/433V with Off Load Tap Switch, Buchholtz relay winding temperature indicator, oil temperature indicator, , oil level indicator with + 5% to -10% Steps of 2.5%, HT and LT Cable Entry Box Type, stacked core with oil as per IS:1180(Part-1):2014 with all standard accessories as per latest IS standard No:2026/1977 and IS:335, technical specification & ESCOM approved. (External Electrification) ---- etc., complete with all leadEach225022.22225022.221.0FalseNoneNoneFalseNoneFalse225022.220
267639683391NoneV-6 54 12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia" (External Electrification) ---- etc., complete with all leadNo4638.824638.828.0FalseNoneNoneFalseNoneFalse37110.560
267639783391NoneV-6 26 58.02LT Metering Cubicle at Low Tension for 50KW to 150KW having specification and design as per the prototype approval (Excluding Meter cost and modem cost) (External Electrification) ---- etc., complete with all leadNo105572.05105572.051.0FalseNoneNoneFalseNoneFalse105572.050
267639883391NoneV-6 23 53.01CT PT Operated ETV Meter 0.2s Accuracy class with ABT feature and DLMS protocal with ToD with RS232 Port UNIDIRACTIONAL ( Used for HT Installation, LT Metering Cubicle (50-150KW) (External Electrification) ---- etc., complete with all leadNo25923.1825923.181.0FalseNoneNoneFalseNoneFalse25923.180
267639983391NoneV-6 54 12.58.3Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI strip (External Electrification) ---- etc., complete with all leadm169.16169.16100.0FalseNoneNoneFalseNoneFalse16916.00
267640083391NoneV-6 55 12.58.9Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 40x6mm Copper strip (External Electrification) ---- etc., complete with all leadMtr2171.392171.39100.0FalseNoneNoneFalseNoneFalse217139.00
267640183391NoneV-6 55 12.58.11Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600x600x3mm Copper plate (External Electrification) ---- etc., complete with all leadEach9807.599807.5910.0FalseNoneNoneFalseNoneFalse98075.90
267640283391NoneV-6 20 45.07Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Outdoor (External Electrification) ---- etc., complete with all leadSet5374.955374.954.0FalseNoneNoneFalseNoneFalse21499.80
267640383391NoneV-6 20 45.04Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Indoor (External Electrification) ---- etc., complete with all leadSet4147.184147.182.0FalseNoneNoneFalseNoneFalse8294.360
267640483391NoneV-6 15 36.0111 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975. 95 Sqmm, (54 GI Wires - 2.5 mm Dia)" (External Electrification) ---- etc., complete with all leadKm1175782.591175782.590.1FalseNoneNoneFalseNoneFalse117578.2590
267640583391NoneV-6 16 38Providing chain link fencing 50 mm size of 8 guage properly stretched between rectangular Poles and fixed with suitable bolts & nuts, the free ends shall be welded to the Pole and block pipe at top and bottom as required including cost of all materials, labour, lead and lifts, cutting, bending wherever necessary, wastage and lapping etc., complete as per the direction of the engineer incharge for work including two coats of approved quality paint over one coat of primer paint. " (External Electrification) ---- etc., complete with all leadSqm1304.421304.42150.0FalseNoneNoneFalseNoneFalse195663.00
267640683391NoneV-6 20 5.42.2L.T.KIOSK Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG (External Electrification) ---- etc., complete with all leadSq CM0.570.57176000.0FalseNoneNoneFalseNoneFalse100320.00
267640783391NoneV-6 20 5.40.2Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips (External Electrification) ---- etc., complete with all leadMtr4539.74539.76.0FalseNoneNoneFalseNoneFalse27238.20
267640883391NoneV-6 20 5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm (External Electrification) ---- etc., complete with all leadMtr403.09403.0912.0FalseNoneNoneFalseNoneFalse4837.080
267640983391NoneV-6 20 5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel (External Electrification) ---- etc., complete with all leadMtr999.13999.1312.0FalseNoneNoneFalseNoneFalse11989.560
267641083391NoneV-6 17 5.15.15Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE 250Amps 35kA (External Electrification) ---- etc., complete with all leadEach31117.0731117.071.0FalseNoneNoneFalseNoneFalse31117.070
267641183391NoneV-6 19 5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C (External Electrification) ---- etc., complete with all leadEach680.62680.623.0FalseNoneNoneFalseNoneFalse2041.860
267641283391NoneV-6 PWD SR 4210.1.3Supplying, installing, testing and commissioning of 25KVA/20kw Diesel Generator set with following specifications. Power rating as per standard reference condition as per-BS 5514 / ISO 3046 / ISO 8528 & IS 1002 / ISO 3046 Generator set specificationsEngine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor 12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade),Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation 415 Volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming toIS/IEC 60034-1. The Alternator is brushless type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have + 1.0 % Voltage regulation (max) in static conditions- IP: 23 protections with insulation class H. Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating lamps for ‘Load On’ and ‘Set Running’, Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections. Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight. Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current Frequency, Provide Engine Data, Starting battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,- Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode. Acoustic enclosure: The acoustic enclosure shall be made of 1.6 mm thick CRCA sheets in suitable approved shade and a structural/ sheet metal base frame painted in black. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75dBA at 1 mtr sound levels specified by Ministry of Environment & Forest. The enclosure has the following features: Specially designed to meet stringent MOEF CPCB norms of 75dBA load under free field conditions, Two point lifting for easy handling at customer site, Designed to have optimum serviceability, Air inlet louvers specially designed to operate at rated load made on special purpose CNC machines for consistency in quality and workmanship, Powder coated forlong DG Set ---- etc., complete with all leadSet596175.08596175.081.0FalseNoneNoneFalseNoneFalse596175.080
267641383391NoneV6 PWD SR 42 10.2.1Supply, Erection, testing and commissioning of AMF panel suitable for .KVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .amps 4 pole contactor for alternator with thermal O/L relay,. Amps 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, .capacity bypass switch and frequency sensing, PCC 1301 controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ KVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMf module by pass Mode, Battery charger unit with inbuilt Auto/Manual and flat/Boost facility. 25 KVA DG Set ---- etc., complete with all leadEach77592.4677592.461.0FalseNoneNoneFalseNoneFalse77592.460
267641483391NoneV-6, Page no 6, 2.5.9Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 4C x 2.5 mm2 ---- etc., complete with all leadMtr195.6195.650.0FalseNoneNoneFalseNoneFalse9780.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17081587530000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17081587530000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17081587530001NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of Karnataka public Procurement on or before the last date and time of bid submission.None
17081614600000NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of Karnataka public Procurement portal due to internet connectivity issues and technical glitches at bidders endNone
17081615090000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejectionNone
17081615760000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidderNone
17081615890000NoneNoneELIGIBILITYThe tenderer shall bear all costs associated with the preparation and submission of his tender, and the employer will in no case be responsible and liable for those costsNone
17081617330000NoneNoneELIGIBILITYConditional tenders will not be accepted.None
17081617430000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete manner.None
17081617530000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt., orders as may be modified from time to time.None
17081617630000NoneNoneELIGIBILITYAny discrepancies observed in the documents uploaded by the tenderer the tender shall liable to rejected.None
17081617750000NoneNoneELIGIBILITYEarnest Money Deposit will have to be in any one of the forms as per the instructions in the financial bid document and shall have to be valid for 45 days beyond the validity of the tenderNone
17081617870000NoneNoneELIGIBILITYAll formats prescribed in the bid documents shall be filled in complete manner (section 2 & of the bid document)and shall be uploaded properly, signed by tenderer. Necessary certificates shall be uploaded along with the formats wherever required. General documents section can be used for this purposeNone
17081617950000NoneNoneELIGIBILITYTenderers are required to read the Bid Documents carefully before submission of their bidNone
17081618060000NoneNoneELIGIBILITYIf the tenderer quotes bid price below the estimated contract value (Amount put to tender) then the tenderer has to submit the additional security deposit equal to the difference in cost and the additional security deposit should have a validity for the period of executionNone
17081618160000NoneNoneELIGIBILITYIf the numbers of page to be attached in one particular attachment is more, then all the pages can be put into one folder, zipped and then attached or else all the pages can be pasted in one word file and then this word file could be converted to PDF (portable documents format) format and then attached. (Please contract help desk from 9.00 AM to 9.00 PM ( Monday to Saturday) Ph No: 91-8046010000 and 91-8068948777 or send query through Karnataka public procurement portal through query option on or before specified time.None
17081618250000NoneNoneELIGIBILITYThe Contractor shall strictly take all reasonable steps to protect the environment on and off the site and to avoid damage or nuisance to persons or to property of the public or others resulting from pollution, noise or other causes arising as a consequence of his methods of operation.None
17081618340000NoneNoneELIGIBILITYMaterials like, steel (primary), cement, bitumen etc., required for the work shall be procured by the tenderer themselves and should be got tested positive by the quality control authority before use on the work.None
17081618440000NoneNoneELIGIBILITYTenderer should have latest GST Registration and latest clearance certificate in their nameNone
17081618560000NoneNoneELIGIBILITYThe Rates quoted by the tenderer shall be inclusive of GST.None
17081618640000NoneNoneELIGIBILITYSpecial Instructions to tenderers - as per bid document.None
17081618730000NoneNoneELIGIBILITYThe Defects Liability Period is 1 year from the date of completion of the work.None
17081618820000NoneNoneELIGIBILITYTotal value of Civil Engineering Construction works executed in the and payments received in the last five year i.e., 2018-19, 2019-20, 2020-21 2021-22 & 2023-24.None
17081618920000NoneNoneELIGIBILITYThe Tenderers are bound to furnish the original certified documents to the employer within 3 days from the day of opening of technical bid for verification, failing which the bid of tenderer will be considered as technically non responsive.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneClause ITT 3.2(b)To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2018-19 to 2022-23) The tenderer should have been Satisfactorily completed at least one Satisfactorily completed at least one Similar work of value not less than Rs.251.00 Lakhs as prime contractor. Note : The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (b).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(c) To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2018-19 to 2022-23).Executed in any one year, the following minimum quantities of work Sl. No Description of key items of works Quantity 1)Earthwork Excavation 2300.00 Cum,2)RCC and PCC 530.00 Cum 3)Steel Reinforcement for RCC work 37.00 Tonnes 4) Cement Concrete Block Masonry/Solid Block Masonry /Load Bearing Wall/Aerated block 1500.00 sqm 5)Flooring/Dadooing(Vitrified/Granite/ Ceramic/Cement concrete/cladding/ dadooing) 2900.00 Sqm,6)Plastering 4000.00 Sqm,7)Painting 7000.00 Sqm, 8)M S grill 1500.00 kg 8)WPC-750.00sqm. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2(c)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(d) The tenderer or his identified sub contractor should possess required valid electrical license for executing building electrification works issued by KPWD/ Government electrical Inspectorate and should have executed similar Building electrical works totaling Rs.35.00 Lakhs in any one financial year.Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (d).The letter of willingness of the sub contractor to be engaged for electrical, should be obtained and uploaded in the KPP-portal.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(e)The Tenderer or his identified sub-contractor should possess valid license for executing water supply/sanitary engineering works issued by BWSSB/ KUWS&DB and should have executed similar building water supply/sanitary engineering works totaling Rs.20.00 Lakhs in any one financial year. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (e).The letter of willingness of the sub contractor to be engaged for water supply & Sanitary, should be obtained and uploaded in the KPP-portal.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneList of existing commitments and ongoing worksClause 3.6 Tenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated for prime contractor are as under Assessed available tender capacity AxNx1.5- B Where A maximum value of civil engineering works executed in any one year during the last five years 2018-19 to 2022-23 updated to 2023-24 price level taking into account the completed as well as works in progress. N Number of years prescribed for completion of the works for which tenders are invited. B Value, at 2023 24 price level, of existing commitments and ongoing works to be completed during the next 06 months. Note:The statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed should be countersigned by the Employer in charge, not below the rank of an Executive Engineer or equivalent. certificate issued by the officer not less than the rank of Executive Engineer Ongoing commitments and Bids submitted for the works.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- certificate issued by the officer not lessthan the rank of Executive Engineer Ongoing commitments and Bids submitted for the works
NoneNoneNoneNoneClause ITT 3.3 (a)Equipment capacity Each tenderer should further demonstrate(a) available by owning at least 50% of the required/specified key and critical equipment for this work and (b) the remaining 50% can be deployed on ease/hire basis for all works provided, the relevant documents (commitment agreements etc.,) for availability for this work are furnished. Sl.No. Description of Equipment Quantity 1) Min 10 cft capacity Concrete Mixer-2No. 2) Steel Centering sheets -500sqmtr, 3)Tipper-2 Nos 4)Excavator-1 No.5)Water tanker-1 No.6) Bar Bending and cutting machine -1 NoCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Invoice/ Receipt should be uploaded.
NoneNoneNoneNoneList of Minimum Key Personnel to be deployed by the contractor at site for Contract work Sl No Position Qualification and Requirement No Of Persons 1) Project Manager B.E. Civil with minimum experience of 15 years in the Construction of buildings and should have been working in permanent role of the organization for at least two years 1 (One) 2)Site Engineer BE Civil with minimum experience of 7 years in the Construction of buildings Or Diploma in Civil Engineering with minimum experience of 10 years in the Construction of buildings and should have been working in permanent role of the organization for at least two years 2 Two Nos 3)Electrical Engineer BE Electrical with minimum experience of 5 years in the Construction of buildings Or Diploma in Electrical Engineering with minimum experience of 10 years in the Construction of buildings- 1No and should have been working inpermanent role of the organization for at least two years.Educational and Experience certificates should be uploadedCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Educational and Experience certificates should be uploaded
NoneNoneNoneNoneKPWD Class-I Registration Certificate.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- KPWD Class-I Registration Certificate issued be competent authority
NoneNoneNoneNoneClause ITT 3.2(a): To qualify for award of this contract, each Tenderer in his / its name should have in the last five years i.e.(2018-19 to 2022-23).The tenderer should have been achieved in at least two financial years i.e(2018-19 to 2022-23) a minimum annual financial turnover (in all classes of civil Engineering construction works only) of Rs.1004.00 Lakhs. Note : a) For Clause 3.2 (a) the certificate Turn over and balance sheet duly certified by the charted accountant is to be submitted.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneClause 3.3(b)Liquid assets and /or availability of credit facilities of not less than Rs.151.00 Lakhs (Credit lines / letter of credit/ certificates from banks for meeting the fund requirement etc.(As per the prescribed format in clause 1.10 of SECTION 3, QUALIFICATION INFORMATION of this document.) as prime Contractor.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover Certificate and balance sheet issued by Charted accountant.TrueTechnical Bid
The Work done certificate should be issued by the Officer not less than the rank of Executive EngineerTrueTechnical Bid
KPWD Class-I Registration Certificate issued by Competent AuthorityTrueTechnical Bid
Tenderer should have latest GST Registration PAN Card and latest 3 GSTclearance certificate in their name.TrueTechnical Bid
Tenderer should have ESI & PF Certificates his/firm name and PF paid receipt of last month.TrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1708167635000
version0
createdDateNone
modifiedDateNone
blockNumberOffice of the Chief Engineer, Engineering Wing, Arogya Soudha, 3rd floor, Leprosy Hospital premises, 1st cross, Magadi Road
streetNone
cityBengaluru
stateKarnataka
pin560023
tenderRecallDTONone