| 2584851 | 80266 | None | code01 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. In area of light jungle | Hectare | 165946.2 | 165946.2 | 0.0012 | False | None | None | False | None | False | 199.13544 | 0 |
| 2584852 | 80266 | None | code02 | Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering & leveling the ground for all works other than foundation & depth in all kinds of soil not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work | Cum | 76.65 | 76.65 | 15.39 | False | None | None | False | None | False | 1179.6435 | 0 |
| 2584853 | 80266 | None | code03 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. The cost of steel reinforcement & formwork shall be paid separatelyMix 1 4 8 M5 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5466.3 | 5466.3 | 1.93 | False | None | None | False | None | False | 10549.959 | 0 |
| 2584854 | 80266 | None | code04 | Providing Coursed rubble masonry first sort with hard stone in foundation and plinth with Cement mortar 1 ratio 6 1 cement ratio 6 coarse sand | Cum | 4987.5 | 4987.5 | 2.47 | False | None | None | False | None | False | 12319.125 | 0 |
| 2584855 | 80266 | None | code05 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1 ratio 6 1 cement 6 coarse sand | Cum | 5619.6 | 5619.6 | 2.87 | False | None | None | False | None | False | 16128.252 | 0 |
| 2584856 | 80266 | None | code06 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. The cost of steel reinforcement, dowel bars & formwork to be paid separately M20 design mix Using 20mm nominal size graded crushed coarse aggregates | Cum | 6240.15 | 6240.15 | 0.97 | False | None | None | False | None | False | 6052.9455 | 0 |
| 2584857 | 80266 | None | code07 | Appendix I Additionalities for Formwork, Centering & Scaffolding Foundation upto Plinth b. All other types | Cum | 187.2 | 187.2 | 0.97 | False | None | None | False | None | False | 181.584 | 0 |
| 2584858 | 80266 | None | code08 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. The cost of steel reinforcement, dowel bars & formwork to be paid separately M20 design mix Using 20mm nominal size graded crushed coarse aggregates | Cum | 6491.1 | 6491.1 | 1.27 | False | None | None | False | None | False | 8243.697 | 0 |
| 2584859 | 80266 | None | code09 | Appendix I Additionalities for Formwork, Centering & Scaffolding Columns & Piers | Cum | 4543.77 | 4543.77 | 1.27 | False | None | None | False | None | False | 5770.5879 | 0 |
| 2584860 | 80266 | None | code10 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. The cost of steel reinforcement, dowel bars & formwork to be paid separately M20 design mix Using 20mm nominal size graded crushed coarse aggregates | Cum | 6491.1 | 6491.1 | 2.26 | False | None | None | False | None | False | 14669.886 | 0 |
| 2584861 | 80266 | None | code11 | Appendix I Additionalities for Formwork, Centering & Scaffolding Beams & Lintels of Building | Cum | 3894.66 | 3894.66 | 2.26 | False | None | None | False | None | False | 8801.9316 | 0 |
| 2584862 | 80266 | None | code12 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. The cost of steel reinforcement, dowel bars & formwork to be paid separately M20 design mix Using 20mm nominal size graded crushed coarse aggregates | Cum | 6491.1 | 6491.1 | 1.81 | False | None | None | False | None | False | 11748.891 | 0 |
| 2584863 | 80266 | None | code13 | Appendix I Additionalities for Formwork, Centering & ScaffoldingRoof Straight & Arched | Cum | 3245.55 | 3245.55 | 1.81 | False | None | None | False | None | False | 5874.4455 | 0 |
| 2584864 | 80266 | None | code14 | Providing steel Fe 500 for RCC work | Tonne | 84311.85 | 84311.85 | 0.49 | False | None | None | False | None | False | 41312.8065 | 0 |
| 2584865 | 80266 | None | code15 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1 ratio4 1 cement 4 coarse sand including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work | Cum | 7295.4 | 7295.4 | 8.84 | False | None | None | False | None | False | 64491.336 | 0 |
| 2584866 | 80266 | None | code16 | Providing Mathi Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves excluding cost of cement concrete and side clamps but including cost of materials, labour, usage charges complete as per specifications | Cum | 79111.2 | 79111.2 | 0.207 | False | None | None | False | None | False | 16376.0184 | 0 |
| 2584867 | 80266 | None | code17 | Providing and fixing in position fully panelled Mathi Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. excluding cost of fixtures | Sqm | 4783.8 | 4783.8 | 2.52 | False | None | None | False | None | False | 12055.176 | 0 |
| 2584868 | 80266 | None | code18 | Providing and fixing in position Mathi Nandi wood fully panelled shutters for windows with stiles and rails of 35mm. thick, 75mm wide in two halves with panels of 25mm thick including cost of materials, labour charges, usage charges complete as per specifications. excluding cost of fixtures | Sqm | 4856.25 | 4856.25 | 4.86 | False | None | None | False | None | False | 23601.375 | 0 |
| 2584869 | 80266 | None | code19 | Providing and fixing Structural Steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge | Kg | 101.85 | 101.85 | 102.06 | False | None | None | False | None | False | 10394.811 | 0 |
| 2584870 | 80266 | None | code20 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1ratio3ratio6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications | Nos | 1555.05 | 1555.05 | 1.0 | False | None | None | False | None | False | 1555.05 | 0 |
| 2584871 | 80266 | None | code21 | Fixing of window frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1ratio3ratio6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debries with lead upto 50 m. including cost of materials, labour charges, complete as per specifications | Nos | 1057.35 | 1057.35 | 4.0 | False | None | None | False | None | False | 4229.4 | 0 |
| 2584872 | 80266 | None | code22 | Providing 12 mm cement plaster with cement mortar 1 ratio 6 1 cement 6 fine sand including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge | Sqm | 207.9 | 207.9 | 9.24 | False | None | None | False | None | False | 1920.996 | 0 |
| 2584873 | 80266 | None | code23 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1 ratio 5 1 cement ratio 5 coarse sand finished with a top layer 6 mm thick cement plaster with cement mortar 1 ratio 6 1 cement 6 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge | Sqm | 322.35 | 322.35 | 77.22 | False | None | None | False | None | False | 24891.867 | 0 |
| 2584874 | 80266 | None | code24 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm average thick base of cement mortar 1ratio4 1 cement ratio 4 coarse sand laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the EngineerinCharge. Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent | Sqm | 3013.5 | 3013.5 | 9.24 | False | None | None | False | None | False | 27844.74 | 0 |
| 2584875 | 80266 | None | code25 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1 ratio3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications | Sqm | 1088.85 | 1088.85 | 1.82 | False | None | None | False | None | False | 1981.707 | 0 |
| 2584876 | 80266 | None | code26 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade New work two coats over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge | Sqm | 110.25 | 110.25 | 45.08 | False | None | None | False | None | False | 4970.07 | 0 |
| 2584877 | 80266 | None | code27 | Finishing walls with water proofing cement paint of required shade New work Two coats applied at 4.84 kg per 10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge | Sqm | 69.3 | 69.3 | 54.28 | False | None | None | False | None | False | 3761.604 | 0 |
| 2584878 | 80266 | None | code28 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied at 0.90 ltr per 10 m² over an under coat of primer applied at 0.75 ltr per 10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineerincharge | Sqm | 110.25 | 110.25 | 16.61 | False | None | None | False | None | False | 1831.2525 | 0 |
| 2584879 | 80266 | None | code29 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied at 0.90 ltr per 10 m² over an under coat of primer applied at 0.80 ltr per 10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineerincharge | Sqm | 111.3 | 111.3 | 4.86 | False | None | None | False | None | False | 540.918 | 0 |
| 2584880 | 80266 | None | code30 | Water purification plants Supplying, Installation and Commissioning of automatic Water purification plant RO plus UF with all accessories piping, product water tank on single phase power supply as per the enclosed detailed Technical Specifications including cost of material, loading and unloading and as directed by the Engineer in charge. Ref detailed specification enclosed seperatly. Note 1.The above rates mentioned are only for the preparation of estimate purpose. 2. All items are to be of BSI NFS standards,with BSI NFS mark . 3. Tenders to be invited for procurement. 4. No direct payment should be made under any situation or condition or on any account. 5. After commissioning of plant necessary testing to be done for the satisfactory of Engineer Incharge. Note Refer the ANNEXURE F for Detailed Specification of Each components For 1000 LPH FRP Skid Type NOTE FOR WATER PURIFICATION PLANT1. For Antiscalant use only NSF 60 approved chemicals.2. Low level sensor indicator to be provider for the antiscalant tank that will shut down the plant during the low level of
the antiscalant.3. Piping from output of Pure water Tank to coin vending machinesmart card shall be in stainless steel 304.4. ROUF system must be fully automatic or compatible for remote monitoring, control and data transmission.5. The high pressure pump shall be fully stainless steel including impeller.6. For detailed specifications of civil and electrical items of works refer PWD SOR.7. All component materials of works should be food grade & conform to relevant codes of drinking water standards
national international.8. The system shall be designed based on water quality and rating of items shall be compatible to each other.9. The system shall have integrated pretreatment modules for removal of suspended solids along with pressure gauge.10. The system shall have inbuilt protection to high pressure pump by way of low high pressure switch.11. Online rotameter shall be provided for measuring flow. Blending cartridge shall be provided to adjust taste TDS | Nos | 478117.5 | 478117.5 | 1.0 | False | None | None | False | None | False | 478117.5 | 0 |
| 2584881 | 80266 | None | code31 | Providing and fixing unplasticised PVC connection pipe with brass
unions 20 mm nominal bore | Nos | 133.35 | 133.35 | 35.0 | False | None | None | False | None | False | 4667.25 | 0 |
| 2584882 | 80266 | None | code32 | Providing and fixing brss bib cock of approved quality etc | Nos | 362.25 | 362.25 | 4.0 | False | None | None | False | None | False | 1449.0 | 0 |
| 2584883 | 80266 | None | code33 | Supplying and fixing polyethylene water storage tanks etc. complete ted | Nos | 7875.0 | 7875.0 | 1.0 | False | None | None | False | None | False | 7875.0 | 0 |
| 2584884 | 80266 | None | code34 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends, metal PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25mm dia 2mm thick | Mtr | 73.5 | 73.5 | 15.0 | False | None | None | False | None | False | 1102.5 | 0 |
| 2584885 | 80266 | None | code35 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25 mm dia 2 mm thick | Mtr | 84.0 | 84.0 | 15.0 | False | None | None | False | None | False | 1260.0 | 0 |
| 2584886 | 80266 | None | code36 | Supplying and fixing PVCmetal conduit Deep junction box 25 mm deep Junction box | Nos | 53.55 | 53.55 | 4.0 | False | None | None | False | None | False | 214.2 | 0 |
| 2584887 | 80266 | None | code37 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete.10 x 7x 3 254 x 178 x 76 mm | Nos | 106.05 | 106.05 | 1.0 | False | None | None | False | None | False | 106.05 | 0 |
| 2584888 | 80266 | None | code38 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete.8 x 6x 3 203 x 152 x 76 mm | Nos | 78.75 | 78.75 | 1.0 | False | None | None | False | None | False | 78.75 | 0 |
| 2584889 | 80266 | None | code39 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete.4x 4x 3 101 x 101 x 76 mm | Nos | 72.45 | 72.45 | 2.0 | False | None | None | False | None | False | 144.9 | 0 |
| 2584890 | 80266 | None | code40 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete. 12x 9x 3 300 x 228 x 76 mm | Nos | 110.25 | 110.25 | 1.0 | False | None | None | False | None | False | 110.25 | 0 |
| 2584891 | 80266 | None | code41 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet gang box, the other end of the wires shall be terminated with sufficient loose length in a wood PVC round block. complete for each outlet. GROUP A Short point upto 3m from tapping point to out let via switch | Point | 289.8 | 289.8 | 2.0 | False | None | None | False | None | False | 579.6 | 0 |
| 2584892 | 80266 | None | code42 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet gang box, the other end of the wires shall be terminated with sufficient loose length in a wood PVC round block. complete for each outlet. GROUP A Medium point above 3m upto 6m from tapping point to out let via switch | Point | 405.3 | 405.3 | 2.0 | False | None | None | False | None | False | 810.6 | 0 |
| 2584893 | 80266 | None | code43 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet gang box, the other end of the wires shall be terminated with sufficient loose length in a wood PVC round block. complete for each outlet. GROUP A Medium point above 3m upto 6m from tapping point to out let via switch | Point | 595.35 | 595.35 | 2.0 | False | None | None | False | None | False | 1190.7 | 0 |
| 2584894 | 80266 | None | code44 | Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS6941990 & confirming to GTP of 3C X 1.5 mm2 | Mtr | 72.45 | 72.45 | 15.0 | False | None | None | False | None | False | 1086.75 | 0 |
| 2584895 | 80266 | None | code45 | Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS6941990 & confirming to GTP of 4C x 1.5 mm2 | Mtr | 92.4 | 92.4 | 15.0 | False | None | None | False | None | False | 1386.0 | 0 |
| 2584896 | 80266 | None | code46 | Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS6941990 & confirming to GTP of 6C x 1.5 mm2 | Mtr | 117.6 | 117.6 | 15.0 | False | None | None | False | None | False | 1764.0 | 0 |
| 2584897 | 80266 | None | code47 | Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS6941990 & confirming to GTP of 8C x 1.5 mm2 | Mtr | 165.9 | 165.9 | 15.0 | False | None | None | False | None | False | 2488.5 | 0 |
| 2584898 | 80266 | None | code48 | Supplying 6A flush type socket and 6 A flush type SP switch either surface flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 6A 3 or 5 Way | Nos | 150.15 | 150.15 | 2.0 | False | None | None | False | None | False | 300.3 | 0 |
| 2584899 | 80266 | None | code49 | Supplying 6A flush type socket and 6 A flush type SP switch either surface flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 6A 2 Way | Nos | 127.05 | 127.05 | 2.0 | False | None | None | False | None | False | 254.1 | 0 |
| 2584900 | 80266 | None | code50 | Supplying and fixing surface flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick C.C wall, including necessary rawl plugs, Machine NF screws etc., complete.13 Way | Nos | 95.55 | 95.55 | 2.0 | False | None | None | False | None | False | 191.1 | 0 |
| 2584901 | 80266 | None | code51 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles.Single phase AC supply conforming to ISS374 1979 and with double ball bearing system.4 Sweep 1200 mm Regular model | Nos | 2189.25 | 2189.25 | 1.0 | False | None | None | False | None | False | 2189.25 | 0 |
| 2584902 | 80266 | None | code52 | Supplying and fixing regular MCB distribution boards on wall wood board flush mounting using required clA, bolts,nuts etc., with provision for fixing suitable type capacity MCBs single phase3 phase single door with powder coated painting Made out of 14 SWG MS enclosure iii Double Door 6 Way TP & N | Nos | 3921.75 | 3921.75 | 1.0 | False | None | None | False | None | False | 3921.75 | 0 |
| 2584903 | 80266 | None | code53 | Supplying & fixing of retrofit type LED bulb 18 W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70 percent efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5 percent of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20 percent, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.18W, 6500K | Nos | 457.8 | 457.8 | 3.0 | False | None | None | False | None | False | 1373.4 | 0 |