createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1708331750508
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd1126000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose16-03-2024 17:00:00
tenderQueryClose04-03-2024 17:00:00
technicalBidOpen19-03-2024 11:00:00
publishedDate19-02-2024 14:40:18
publishedByPostBMTC_EE_HOFF_BNG
publishedByUserKPE14985 - RANGARAJU B P
bidValidityPeriod90
noOfCalls1
preBidMeetingDate05-03-2024 15:30:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonSrinivas S
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08022537447
mobileNumber9845661685
tenderSupplierListNone
tenderSchedule
createdTs1708331750534
version5
createdDateNone
modifiedDateNone
tenderNumberBMTC/2023-24/BD/WORK_INDENT31
titleConstruction of Regional Drivers Training Center in Bidadi Industrial Area, Ramanagara Dist, Bangalore
descriptionConstruction of Regional Drivers Training Center in Bidadi Industrial Area, Ramanagara Dist Bangalore
categoryWORKS
categoryTextWorks
ecv63541987.53
deptNameBangalore Metropolitan Transport Corporation
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location3586
locationNameBangalore Metropolitan Transport Corporation Office Bengaluru
provisionalAmount75100000.0
groupOverheadTotalNone
fileNumber042
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17083317510001NoneNoneBuildingsConstruction of Regional Drivers Training Center in Bidadi Industrial Area, Ramanagara Dist, Bangalore63541987.53
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
269279784710Nonecode01Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the workCum105.06105.062372.8FalseNoneNoneFalseNoneFalse249286.3680
269279884710Nonecode02Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.(V2-P 5/4.1)Sqm121.54121.54518.0FalseNoneNoneFalseNoneFalse62957.720
269279984710Nonecode03KSRB 2.8 : Providing and filling in foundation with granite/ trap broken metal 100mm. And down size & with approved sand including had packing, ramming, watering, including cost of all meterials and labour with all lead and lift. Complete as pe specifications. specification No KBSCum2762.462762.4697.0FalseNoneNoneFalseNoneFalse267958.620
269280084710Nonecode04Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregatesCum5833.925833.92362.58FalseNoneNoneFalseNoneFalse2115262.71360
269280184710Nonecode05Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. excluding cost of steel reinforcement & including cost of centerinf scaffolding and formwork M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for footingCum7048.177048.17133.0FalseNoneNoneFalseNoneFalse937406.610
269280284710Nonecode06Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. excluding cost of steel reinforcement & including cost of centerinf scaffolding and formwork M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Pedestal columnCum11094.3411094.349.5FalseNoneNoneFalseNoneFalse105396.230
269280384710Nonecode07Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates columnCum11094.3411094.3414.0FalseNoneNoneFalseNoneFalse155320.760
269280484710Nonecode08Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Beam and RoofCum10572.4410572.4464.0FalseNoneNoneFalseNoneFalse676636.160
269280584710Nonecode09Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Excluding cost of steel reinforcement, dowel bars & including centering,scaffolding, formwork M25Design Mix Using 20 mm nominal size graded crushed coarse aggregates For roof slab StaircaseCum10572.4410572.4475.0FalseNoneNoneFalseNoneFalse792933.00
269280684710Nonecode10Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Excluding cost of steel reinforcement, dowel bars & including centering,scaffolding, formwork M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For ChejjaCum10220.0210220.025.5FalseNoneNoneFalseNoneFalse56210.110
269280784710Nonecode11Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.BuildingsTonne92140.7192140.7138.11FalseNoneNoneFalseNoneFalse3511482.45810
269280884710Nonecode12Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand )Cum6580.676580.67173.0FalseNoneNoneFalseNoneFalse1138455.910
269280984710Nonecode13Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of workCum87.5587.553822.95FalseNoneNoneFalseNoneFalse334699.27250
269281084710Nonecode14Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour, rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum488.22488.224574.2FalseNoneNoneFalseNoneFalse2233215.9240
269281184710Nonecode15Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1349.31349.31060.2FalseNoneNoneFalseNoneFalse1430527.860
269281284710Nonecode16Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1137.121137.12119.0FalseNoneNoneFalseNoneFalse135317.280
269281384710Nonecode17Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specificationsCum101779.45101779.451.61FalseNoneNoneFalseNoneFalse163864.91450
269281484710Nonecode18Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.No1046.481046.4822.0FalseNoneNoneFalseNoneFalse23022.560
269281584710Nonecode19Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. 35 mm thick one side teak and one side commercialSqm4013.914013.9161.0FalseNoneNoneFalseNoneFalse244848.510
269281684710Nonecode20Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance plus or minus 1mm), with wall thickness 2.0 mm (plus or minus 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (plus or minus 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineer- in-charge 42x50 mm PVC Extruded sectionMtr246.17246.1746.0FalseNoneNoneFalseNoneFalse11323.820
269281784710Nonecode21Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.-do- with both side prelamSqm2436.982436.9818.0FalseNoneNoneFalseNoneFalse43865.640
269281884710Nonecode22Providing and fixing of 2 track x 2-panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having a overall size of 60mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm X 58mm with GI reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24mm. Windows shall be provided with 5mm plain float glass, standard hardware & single point locking system with touch lock. Wall thickness of frame & sash shall be of 2 to 2.5 mm. Maximum possible size: 1819 mm x 1819mm (The cost is inclusive of all fixtures and separate charges for minor T and P s shall not be madeSqm5551.75551.769.9FalseNoneNoneFalseNoneFalse388063.830
269281984710Nonecode23Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingKgs173.04173.041729.24FalseNoneNoneFalseNoneFalse299227.68960
269282084710Nonecode24Providing 12 mm cement plaster with cement mortar 1:4 (1 cement:4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm262.65262.651333.0FalseNoneNoneFalseNoneFalse350112.450
269282184710Nonecode25Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-chargeSqm287.37287.371393.0FalseNoneNoneFalseNoneFalse400306.410
269282284710Nonecode26Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth.Mtr67.9867.98510.0FalseNoneNoneFalseNoneFalse34669.80
269282384710Nonecode27Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge..Kgs151.41151.412000.0FalseNoneNoneFalseNoneFalse302820.00
269282484710Nonecode28Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.Sqm585.04585.0485.0FalseNoneNoneFalseNoneFalse49728.40
269282584710Nonecode29Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete Gutter (600 mm over all girth)Mtr1106.221106.2240.0FalseNoneNoneFalseNoneFalse44248.80
269282684710Nonecode30Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size 500x500mmSqm1114.461114.46237.0FalseNoneNoneFalseNoneFalse264127.020
269282784710Nonecode31Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. * Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent.Sqm2937.562937.56177.0FalseNoneNoneFalseNoneFalse519948.120
269282884710Nonecode32Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.Sqm5487.845487.8488.3FalseNoneNoneFalseNoneFalse484576.2720
269282984710Nonecode33Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.Mtr337.84337.84180.0FalseNoneNoneFalseNoneFalse60811.20
269283084710Nonecode34Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.Sqm1492.471492.47263.0FalseNoneNoneFalseNoneFalse392519.610
269283184710Nonecode35Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot restsNo5030.525030.524.0FalseNoneNoneFalseNoneFalse20122.080
269283284710Nonecode36Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lidNo6156.316156.318.0FalseNoneNoneFalseNoneFalse49250.480
269283384710Nonecode37Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixerNo4244.634244.6318.0FalseNoneNoneFalseNoneFalse76403.340
269283484710Nonecode38Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Circular shape 450 mm diaNo1120.641120.6418.0FalseNoneNoneFalseNoneFalse20171.520
269283584710Nonecode39Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge.No6425.146425.1410.0FalseNoneNoneFalseNoneFalse64251.40
269283684710Nonecode40Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. 75mm ( weight of pipe -0.917 kg)Mtr197.76197.7669.0FalseNoneNoneFalseNoneFalse13645.440
269283784710Nonecode41Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. 90mm ( weight of pipe -1.313 kg)Mtr265.74265.7456.0FalseNoneNoneFalseNoneFalse14881.440
269283884710Nonecode42Providing and placing on terrace,(at all floors levels) polyethylene water storage tanks IS 12701 marked , cover with suitable locking arrangements, and making necessary holes for inlet, outlet and over flow pipes,but with out fittings and base support for tanks .Ltr9.279.276000.0FalseNoneNoneFalseNoneFalse55620.00
269283984710Nonecode43Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. 6 Kg/m2: 110mm(weight of pipe -1.894 kg)Mtr368.74368.74417.0FalseNoneNoneFalseNoneFalse153764.580
269284084710Nonecode44Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete..Sqm915.67915.6718.0FalseNoneNoneFalseNoneFalse16482.060
269284184710Nonecode45Providing and fixing chorinated poly vinyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. (external work). 32mm nominal OD pipes mMtr383.16383.16489.0FalseNoneNoneFalseNoneFalse187365.240
269284284710Nonecode46Providing and fixing chorinated poly vinyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. (external work). 25mm nominal OD pipes mMtr304.88304.88450.0FalseNoneNoneFalseNoneFalse137196.00
269284384710Nonecode47Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete. (Concealed work including cutting chases and good the walls etc.20mm DiaMtr390.37390.3795.0FalseNoneNoneFalseNoneFalse37085.150
269284484710Nonecode48Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. 160mm ( weight of pipe -3.923 kg)Mtr665.38665.38594.0FalseNoneNoneFalseNoneFalse395235.720
269284584710Nonecode49Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates with form work for cill CopingCum6723.696723.6910.0FalseNoneNoneFalseNoneFalse67236.90
269284684710Nonecode50Constructing brick masonry chamber of internal dimension 600x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.No4934.734934.7336.0FalseNoneNoneFalseNoneFalse177650.280
269284784710Nonecode51Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.No5617.625617.6222.0FalseNoneNoneFalseNoneFalse123587.640
269284884710Nonecode52Providing and fixing SFRC frame and cover conforming to IS 12592 (part-I)-1988 and IS 12592 (part-II)- 1991 with latest amendment,including cutting slabs to the required size for the opening and fixing the cover in C.C. 1:2:4 and C.M. 1:3 plastering 20 mm thick to all exposed faces, curing for 10 days with all lead and lift with appurtenances.complete .Heavy DutyNo2640.922640.9257.0FalseNoneNoneFalseNoneFalse150532.440
269284984710Nonecode53Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/ beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete For Straight PortionSqm4108.674108.6755.0FalseNoneNoneFalseNoneFalse225976.850
269285084710Nonecode54Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,Kgs581.95581.95450.0FalseNoneNoneFalseNoneFalse261877.50
269285184710Nonecode55Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm103.0103.01710.0FalseNoneNoneFalseNoneFalse176130.00
269285284710Nonecode56Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm160.68160.682312.95FalseNoneNoneFalseNoneFalse371644.8060
269285384710Nonecode57Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm179.22179.221133.0FalseNoneNoneFalseNoneFalse203056.260
269285484710Nonecode58Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 g.No871.38871.3828.0FalseNoneNoneFalseNoneFalse24398.640
269285584710Nonecode59Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931No638.6638.635.0FalseNoneNoneFalseNoneFalse22351.00
269285684710Nonecode60Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, , primer, sealant , curing of concrete slabs for 14- days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the work.Cum6956.626956.62624.5FalseNoneNoneFalseNoneFalse4344409.190
269285784710Nonecode61Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Sloped RoofCum11982.0911982.0929.5FalseNoneNoneFalseNoneFalse353471.6550
269285884710Nonecode62Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for BeamsCum11277.2611277.2627.5FalseNoneNoneFalseNoneFalse310124.650
269285984710Nonecode63Providing and fixing 100 mm sand cast Iron grating for gully trap.No48.4148.4121.0FalseNoneNoneFalseNoneFalse1016.610
269286084710Nonecode64Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size 600x600mmSqm1179.351179.3585.0FalseNoneNoneFalseNoneFalse100244.750
269286184710Nonecode65Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of the slab upto 0.50m2Sqm4126.184126.187.0FalseNoneNoneFalseNoneFalse28883.260
269286284710Nonecode66Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink with drain board 510x1040 mm bowl depth 250 mmNo5786.545786.541.0FalseNoneNoneFalseNoneFalse5786.540
269286384710Nonecode67Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.Cum97.8597.8510291.78FalseNoneNoneFalseNoneFalse1007050.6730
269286484710Nonecode68Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2Cum507.79507.792188.65FalseNoneNoneFalseNoneFalse1111374.58350
269286584710Nonecode69Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work Depth exceeding 1.5m, but not exceeding 3 mCum249.26249.26404.97FalseNoneNoneFalseNoneFalse100942.82220
269286684710Nonecode70Construction of Embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded with desired compaction.Cum122.57122.577718.84FalseNoneNoneFalseNoneFalse946098.21880
269286784710Nonecode71Filling available excavated earth (excluding rock)in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cmin depth, consolidating each deposited layer byramming and watering, lead up to 50 m and lift upto1.5 m.Cum273.98273.98443.8FalseNoneNoneFalseNoneFalse121592.3240
269286884710Nonecode72Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Retaining wallCum7178.697178.69140.0FalseNoneNoneFalseNoneFalse1005016.60
269286984710Nonecode73Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Median , KerbCum6852.386852.38270.0FalseNoneNoneFalseNoneFalse1850142.60
269287084710Nonecode74Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For RCC DrainCum8810.218810.21418.0FalseNoneNoneFalseNoneFalse3682667.780
269287184710Nonecode75Providing, laying, spreading and compacting graded stoneaggregate to wet mix macadam specification includingpremixing the Material with water at OMC in mechanical mixplant carriage of mixed Material bytipper to site, laying inuniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.Cum2635.772635.771500.0FalseNoneNoneFalseNoneFalse3953655.00
269287284710Nonecode76Construction of dry lean cement concrete Sub- base over aprepared sub-grade with coarse and fine aggregate conformingo IS: 383, the size of coarse aggregate not exceeding 25 mm,aggregate cement ratio not to exceed 15:1, aggregate gradationafter blending to be as per table 600-1, cement content not to beless than 150 kg/ m3, optimum moisture content to be determinedduring trial length construction, concrete strength not to be lessthan 10 Mpa at 7 days, mixed in a batching plant, transportedto site, laid with a paver with electronic sensor, compacting with8-10 t vibratory roller, finishing and curing.Cum5067.65067.6437.5FalseNoneNoneFalseNoneFalse2217075.00
269287384710Nonecode77Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.All other type of structuresTonne81381.3381381.3343.0FalseNoneNoneFalseNoneFalse3499397.190
269287484710Nonecode78Supplying, fitting and placing Mild Steel Reinforcement complete as per drawing and technical specification.Tonne75924.3975924.3924.5FalseNoneNoneFalseNoneFalse1860147.5550
269287584710Nonecode79Providing and laying 80mm thick factory made precast M -30 grade Cement Concrete Paver Block as per IRC SP 63:2018 & IS 15658 for Commercial Traffic Axle load repetitions upto 10MSA & for Residential Streets of approved shape and colour, laid in required pattern and including over 40mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (WMM/WBM Base to be paid separately as per relevant technical specification)Sqm1195.831195.837055.5FalseNoneNoneFalseNoneFalse8437178.5650
269287684710Nonecode80Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) tobrick/stone masonary including rounding off corners wherever requiredsmooth rendering, providing and removing scaffolding, including costof materials, labour, curing complete as per specifications and as perdirections of Engineer-in-charge.)Sqm342.99342.99240.0FalseNoneNoneFalseNoneFalse82317.60
269287784710Nonecode81Construction of Median and Island with Soil Taken from Roadway Cutting Construction of Median and Island above road level with approved material deposited at site from roadway cutting and excavation for drain and foundation of other structures, spread, graded and compacted as per clause 408Cum378.01378.01360.0FalseNoneNoneFalseNoneFalse136083.60
269287884710Nonecode82Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregatesas per relevant IS Codes machine mixed with super plasticisers laid inayers, well compacted using needle vibrators. The cost includes alllead & lifts, cost of all materials, quality confirming to the requirementsof relevant IS codes , labour,Usagecharges of machinery, curing andall other appurtenances required to complete the work as per technicalspecifications. (The cost The cost of steel reinforcement, dowel bars & formworkto be paid separately)2.5.1 M30 Design Mix Using M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Sump WallCum10825.8210825.8222.0FalseNoneNoneFalseNoneFalse238168.040
269287984710Nonecode83Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum8208.078208.074.07FalseNoneNoneFalseNoneFalse33406.84490
269288084710Nonecode84Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-chargeSqm321.36321.3672.0FalseNoneNoneFalseNoneFalse23137.920
269288184710Nonecode85Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarseaggregatesCum6403.516403.515.63FalseNoneNoneFalseNoneFalse36051.76130
269288284710Nonecode86Geophysical investigation at site for sinking borewells for supplyingdrinking water to the habitation either through the Hand Pump MWS orP.W.S.S, by vertical electrical sounding by adopting Venner orSchlumbergers’s method, including reconnaissance survey of geologicalformation. Geophysical investigation of existing ground water in thevicinity, its quality, quantity and acceptability of the users, indicatingthe location of the site, recommended depth of casing pipe required toseal the top unconsolidated formation including an extra depth of 1.0metre in consolidated formation for proper seating of casing pipe, depthof drilling required to cover full depth of aquifer proposed to be tapped,probable yield and other information required including transportationof instruments and accessories to work site, engaging technical personaland labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M(for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%,b) Above 30 M - 30% (Measurement of overburden is restricted to thedepth of casing pipe fixed excluding initial depth of 20M and projectionabove ground level). 2) A sum of Rs. 100/- is to be deducted for DryBorewell towards yield test.4 O040ANo5446.645446.641.0FalseNoneNoneFalseNoneFalse5446.640
269288384710Nonecode87Sinking of Borewell of 165mm dia clear using super fast hydraulic rig ofcapacity 300 PSIG & above 1100 CMF & above in all strata includingover burdern upto 20 m. Fixing of casing pipes, collars and cap withnecessary cutting, threading and welding including transportation ofrig and supporting vehicle, crew charges and cost of consumables etc.,complete including yield testing at the final depth with a minimumworking of compressor for one hour (Excluding cost of casing pipes,collars, cap etc., complete ) 1.1 O010A Borewell depth of 0 to 50 mMtr381.1381.150.0FalseNoneNoneFalseNoneFalse19055.00
269288484710Nonecode88Sinking of Borewell of 165mm dia clear using super fast hydraulic rig ofcapacity 300 PSIG & above 1100 CMF & above in all strata includingover burdern upto 20 m. Fixing of casing pipes, collars and cap withnecessary cutting, threading and welding including transportation ofrig and supporting vehicle, crew charges and cost of consumables etc.,complete including yield testing at the final depth with a minimumworking of compressor for one hour (Excluding cost of casing pipes,collars, cap etc., complete ) 1.1 O010A Borewell depth of 50 to 100 mMtr477.92477.9250.0FalseNoneNoneFalseNoneFalse23896.00
269288584710Nonecode89Sinking of Borewell of 165mm dia clear using super fast hydraulic rig ofcapacity 300 PSIG & above 1100 CMF & above in all strata includingover burdern upto 20 m. Fixing of casing pipes, collars and cap withnecessary cutting, threading and welding including transportation ofrig and supporting vehicle, crew charges and cost of consumables etc.,complete including yield testing at the final depth with a minimumworking of compressor for one hour (Excluding cost of casing pipes,collars, cap etc., complete ) 1.1 O010A Borewell depth of 100 to 150 mMtr507.79507.7950.0FalseNoneNoneFalseNoneFalse25389.50
269288684710Nonecode90Sinking of Borewell of 165mm dia clear using super fast hydraulic rig ofcapacity 300 PSIG & above 1100 CMF & above in all strata includingover burdern upto 20 m. Fixing of casing pipes, collars and cap withnecessary cutting, threading and welding including transportation ofrig and supporting vehicle, crew charges and cost of consumables etc.,complete including yield testing at the final depth with a minimumworking of compressor for one hour (Excluding cost of casing pipes,collars, cap etc., complete ) 1.1 O010A Borewell depth of 150 to 200 mMtr589.16589.1650.0FalseNoneNoneFalseNoneFalse29458.00
269288784710Nonecode91Sinking of Borewell of 165mm dia clear using super fast hydraulic rig ofcapacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap withnecessary cutting, threading and welding including transportation ofrig and supporting vehicle, crew charges and cost of consumables etc.,complete including yield testing at the final depth with a minimumworking of compressor for one hour (Excluding cost of casing pipes,collars, cap etc., complete ) 1.1 O010A Borewell depth of 200 to 250 mMtr691.13691.1350.0FalseNoneNoneFalseNoneFalse34556.50
269288884710Nonecode92Sinking of Borewell of 165mm dia clear using super fast hydraulic rig ofcapacity 300 PSIG & above 1100 CMF & above in all strata includingover burdern upto 20 m. Fixing of casing pipes, collars and cap withnecessary cutting, threading and welding including transportation ofrig and supporting vehicle, crew charges and cost of consumables etc.,complete including yield testing at the final depth with a minimumworking of compressor for one hour (Excluding cost of casing pipes,collars, cap etc., complete ) 1.1 O010A Borewell depth of 250 to 300 mMtr762.2762.250.0FalseNoneNoneFalseNoneFalse38110.00
269288984710Nonecode93Sinking of Borewell of 165mm dia clear using super fast hydraulic rig ofcapacity 300 PSIG & above 1100 CMF & above in all strata includingover burdern upto 20 m. Fixing of casing pipes, collars and cap withnecessary cutting, threading and welding including transportation ofrig and supporting vehicle, crew charges and cost of consumables etc.,complete including yield testing at the final depth with a minimumworking of compressor for one hour (Excluding cost of casing pipes,collars, cap etc., complete ) 1.1 O010A Borewell depth of 300 to 350 mMtr894.04894.0450.0FalseNoneNoneFalseNoneFalse44702.00
269289084710Nonecode94Sinking of Borewell of 165mm dia clear using super fast hydraulic rig ofcapacity 300 PSIG & above 1100 CMF & above in all strata includingover burdern upto 20 m. Fixing of casing pipes, collars and cap withnecessary cutting, threading and welding including transportation ofrig and supporting vehicle, crew charges and cost of consumables etc.,complete including yield testing at the final depth with a minimumworking of compressor for one hour (Excluding cost of casing pipes,collars, cap etc., complete ) 1.1 O010A Borewell depth of 350 to 400 mMtr965.11965.1150.0FalseNoneNoneFalseNoneFalse48255.50
269289184710Nonecode95Sinking of Borewell of 165mm dia clear using super fast hydraulic rig ofcapacity 300 PSIG & above 1100 CMF & above in all strata includingover burdern upto 20 m. Fixing of casing pipes, collars and cap withnecessary cutting, threading and welding including transportation ofrig and supporting vehicle, crew charges and cost of consumables etc.,complete including yield testing at the final depth with a minimumworking of compressor for one hour (Excluding cost of casing pipes,collars, cap etc., complete ) 1.1 O010A Borewell depth of 400 to 450 mMtr1219.521219.5250.0FalseNoneNoneFalseNoneFalse60976.00
269289284710Nonecode96Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium dutyMtr1990.991990.9940.0FalseNoneNoneFalseNoneFalse79639.60
269289384710Nonecode97Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendmentsNo154.5154.510.0FalseNoneNoneFalseNoneFalse1545.00
269289484710Nonecode98Providing and laying at site of work MS casing caps as per IS 1239 (part- II) 1982 with all latest amendments if any for any dia. The hickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in chargeNo168.92168.921.0FalseNoneNoneFalseNoneFalse168.920
269289584710Nonecode99Procurement of Ingredients: Procurement of farmyard manure/compost, sand and red-earth (ingredients) required for raising seedlings inclusive of transportation, breaking of clods, sieving and heaping each ingredient separately at nursery site (Ceiling rate) (a) (P 1/1.2a) Fine coarse Red-earth/soilCum539.18539.18450.0FalseNoneNoneFalseNoneFalse242631.00
269289684710Nonecode100Procurement of Ingredients: Procurement of farmyard manure/compost, sand and red-earth (ingredients) required for raising seedlings inclusive of transportation, breaking of clods, sieving and heaping each ingredient separately at nursery site (Ceiling rate) (a) (P 1/1.2b) Natural SandCum1167.461167.4635.0FalseNoneNoneFalseNoneFalse40861.10
269289784710Nonecode101Procurement of Ingredients: Procurement of farmyard manure/compost, sand and red-earth (ingredients) required for raising seedlings inclusive of transportation, breaking of clods, sieving and heaping each ingredient separately at nursery site (Ceiling rate) (a) (P 1/1.2c) Farm yard manure/compostCum1585.271585.2741.0FalseNoneNoneFalseNoneFalse64996.070
269289884710Nonecode102READY MEXICAN CARPET GRASS LAWN: intial preparation of land/basic development land: Developing of first grade lawn by clearing the site and intial earth work excavation of soil to a minium depth of 0.45 m in all types of soil removing the debries unwanted growth etc., and filling upto 0.15M with red earth and top dressing upto 7.5 CM depth with with sand (0.045 cum) Horse manure /FYM (0.0225 cum) (i.e in the 1:1) applying 100 grams of neem cake per 1.0 qmt and application of soil insecticide, fungicides such as furedon/ phorate/agallol recommended doses.Labour Charges: mixing Inputs as per prescribed proportion and quantity and spreading, applying fertilizers,digging, levelling , and dibbling with lawn grass at a spacing of 5cm x5cm & as per the direction of the Officer in charge of the work. (c) Mexican Grass-TurfSqm585.0585.01363.58FalseNoneNoneFalseNoneFalse797694.30
269289984710Nonecode103Planting of Shrubs: Digging pits of size 0.45 x 0.45 x0.45m filling 50% of the pit with top soil and remaining 50% of pit with1:2:3 proportion of sand (0.007), FYM (0.014cm) red earth (0.021cm) and and planting of well grown tree saplings (excluding cost of plants) (a) Normal soilNo68.068.050.0FalseNoneNoneFalseNoneFalse3400.00
269290084710Nonecode104Rose garden/growing of rose plants :Digging pits of 0.6x 0.6 x0.6m size and filling 50% of the pit with top soil and remaining 50% of pit with 1:6:6 proportion of sand (0.008), FYM (0.048cm) red earth (0.048cm), Neem oil cake (200 gram), Bone meal (100gram), Gingali oil (100gram),Suphala (10 gms), Rose mix (5 gms) and other plant protection chemicals and planting of different varieties of rose plants etc. (excluding cost of plants) (a) Normal soilNo177.0177.050.0FalseNoneNoneFalseNoneFalse8850.00
269290184710Nonecode105Planting of trees: Digging pits of size 0.75 x 0.75x 0.75m, filling 50% of the pit with top soil and remaining 50% of pit with 1:2:3 proportion ofsand (0.035cum) FYM (0.070cum) Red earth (0.105 cum) and planting of well grown tree saplings (excluding cost of plants) (a) Normal soilNo307.0307.050.0FalseNoneNoneFalseNoneFalse15350.00
269290284710Nonecode106Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm130.81130.81260.0FalseNoneNoneFalseNoneFalse34010.60
269290384710Nonecode107Providing and fixing 1 mm thick M.S. sheet sliding-shutters, with frame and diagonal braces of 40x40x6 mm angle iron, 3 mm M.S. gusset plates at the junctions and corners, 25 mm dia pulley, 40x40x6 mm angle and T- iron guide at the top and bottom respectively, including applying a priming coat of approved steel primer including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-ChargeSqm5377.635377.6345.0FalseNoneNoneFalseNoneFalse241993.350
269290484710Nonecode108Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.50m For Signage boardsCum266.77266.777.56FalseNoneNoneFalseNoneFalse2016.78120
269290584710Nonecode109Retro-Reflectorised Traffic Signs : Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC:67:2022 made of Class B Type IV retro reflective sheeting fixed over 2 mm thick aluminium sheeting vide clause 803.1, 3mm/4mm thick Aluminium composite material sheet depending on the size of the sign fixed over the back support frame of min 25 x 25 x 3mm angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing.The sign shall be maintained as per section 12 of IRC:67:2022. 60cm equilateral triangle equilateral triangleNo3683.283683.282.0FalseNoneNoneFalseNoneFalse7366.560
269290684710Nonecode110do- 60cm circular triangleNo4425.914425.912.0FalseNoneNoneFalseNoneFalse8851.820
269290784710Nonecode111do- 90cmx75xcm rectangularNo6720.756720.752.0FalseNoneNoneFalseNoneFalse13441.50
269290884710Nonecode112do- 80cmx60cm rectangularNo5579.515579.512.0FalseNoneNoneFalseNoneFalse11159.020
269290984710Nonecode113do- 60cmx50cm rectangularNo4525.824525.822.0FalseNoneNoneFalseNoneFalse9051.640
269291084710Nonecode114do- 60cmx45cm rectangularNo4350.724350.722.0FalseNoneNoneFalseNoneFalse8701.440
269291184710Nonecode115do- 60cmx60cm SquareNo4877.054877.052.0FalseNoneNoneFalseNoneFalse9754.10
269291284710Nonecode116do- 90 cm high octagonNo6697.066697.062.0FalseNoneNoneFalseNoneFalse13394.120
269291384710Nonecode117do- 90 cm high octagonNo5497.115497.112.0FalseNoneNoneFalseNoneFalse10994.220
269291484710Nonecode118Direction and Place Identification Signs upto 0.9 m2 Size Board.Providing and erecting direction and place identification retroreflectorised sign as per IRC:67:2022 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick or Aluminium composite material sheet with overall thickness of 4mm with area not exceeding 0.9 m2 fixed over back support frame of min 35 x 35 x 3mm angle mounted on a mild steel circular pipe 65 NB, firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawingSqm9280.39280.31.8FalseNoneNoneFalseNoneFalse16704.540
269291584710Nonecode119Providing and Fixing of Median Marker that are made of tough, high impact resistant, injection-molded, thermoplastic body with an isosceles trapezoidal structure of length, width and height not less than 15cm, 10cm and 10cm respectively and thickness not less than 1.8mm, the body structure shall be rounded at its acute angle, all the corners and edges. The plastic used for molding the Median Marker shall have a minimum Notched Izod Impact strength value of 600 J/m at room temperature, when tested in accordance with ASTM D256 and shall retain at least 70% of this value when subjected to accelerated weathering for 1000hrs as per ASTM G155 or UL746C. The logo of the manufacturer shall be embossed on either side of the body in the injection molding process. The Median Marker shall have rectangular-shaped, fluorescent yellow color retro- reflective sheeting of size not less than 8.5cm*8.5cm and with fully reflective micro prismatic cube corners as its retro-reflective elements as per IRC 67 2022 and ASTM D4956 type XI specifications reflectivity values. The retro-reflective sheeting shall be one or both sides of the Median Marker and shall be edge protected with no exposed edges which will prevent edge lifting, vandalism, sheeting damage, etc. The Median Marker shall be fixed by a combination of epoxy adhesive and grouting as per MoRTH specification 806No669.5669.520.0FalseNoneNoneFalseNoneFalse13390.00
269291684710Nonecode120Supplying and Fixing of Molded Shank Raised Pavement Markers / Cat's Eye made of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kg tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No RW/NH/33023/10-97 DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 mm, 100 mm and 102 +/- 2 mm and with minimum reflective area of 13 cm2 on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 mm and height not less than 30+/- 2 mm) from the body is to be a minimum value of 500 Kg. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer's recommendation and complete as directed by the engineer.The contractor shall submit a two year warranty for satisfactory field performance including stipulated retro-reflectance of the reflecting panel, to the EngineerNo375.95375.9540.0FalseNoneNoneFalseNoneFalse15038.00
269291784710Nonecode121Supply and installation of retro- reflective Chevron signboards of 600x450mm made out of cube corner micro prismatic grade sheeting confirming to Type XI standards of IRC:67:2022 & ASTM D 4956-09 specification & fixed over 3 mm thick Aluminium Composite Panel sheet having minimum 0.30 mm thick aluminum skin on both sides & fixed over back support frame of 25x25x 3mm MS angle frame. Supported on 75 mm dia OR 75x75x6mm Mild steel with clear height of not less than 2.1 m from the ground level to the bottom of the Sign board & 60 cm below ground level. The sign post should be painted with one coat of red oxide paint and two coats of synthetic enamel paint of black and white colour with bands of 30 cm height, firmly fixed to the ground by means of foundation with M 20 grade cement, concrete foundation size of 45 cm x 45 cm x 60 cm including cost & conveyance of all materials,equipment,machinery & Labour with all leads and lifts for satisfactory completion of the work as directed by Engineer inchargeNo3693.583693.588.0FalseNoneNoneFalseNoneFalse29548.640
269291884710Nonecode122Providing and Laying of Rumble strips with Two component cold plastic with Primer coating rolled on surfacing material solvent free, high build two pack seamless, tough, skid resistant,for material to give total width of 500 mm and height of 10 mm. Ramp provided to give width of 145 mm, width of ribs to be 55mm laid at C/C distance of 35 mm.For these specialised markings high refractive index glass beads of Ri 1.6 are recommended @ 350g/m2. The finished surface to be levelled, uniform and free from streaks and holes, to be applied on the edge lines, including surface cleaning and cost of all materials etc. completeSqm3744.053744.0524.0FalseNoneNoneFalseNoneFalse89857.20
269291984710Nonecode123Providing and Laying of Rumble strips with Two component cold plastic with Primer coating rolled on surfacing material solvent free, high build two pack seamless, tough, skid resistant,for material to give total width of 500 mm and height of 10 mm. Ramp provided to give width of 145 mm, width of ribs to be 55mm laid at C/C distance of 35 mm.For these specialised markings high refractive index glass beads of Ri 1.6 are recommended @ 350g/m2. The finished surface to be levelled, uniform and free from streaks and holes, to be applied on the edge lines, including surface cleaning and cost of all materials etc. completeMtr927.0927.048.0FalseNoneNoneFalseNoneFalse44496.00
269292084710Nonecode124Providing Speed Breakers/Raised pedestrian crossings in Trapezoidal section with 2.5 m Top width and transition length of 0.8 m length and height of 0.1 m as per IRC 99:2018 using Dense Bituminous Macadam (DBM) Gr II and Bituminous Concrete (BC) Gr II for entire formation width & WBM Gr II for Shoulder hump portion only (150 mm thick), completing with road marking paint with applied thermoplastic compound with reflecting glass beeds on bituminous surface and providing 2 Nos. retro reflective traffic signs as per IRC 67 -2022 PedestrianNo39109.139109.12.0FalseNoneNoneFalseNoneFalse78218.20
269292184710Nonecode125Open Conduit System: Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 19/20 mm dia 2 mm thick 1.1.1Mtr71.0771.0760.0FalseNoneNoneFalseNoneFalse4264.20
269292284710Nonecode126Do- 25 mm dia 2 mm thick 1.1.2Mtr83.4383.4380.0FalseNoneNoneFalseNoneFalse6674.40
269292384710Nonecode127Concealed Conduit System: Supplying heavy gauge PVC conduit pipe mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20 mm dia 2 mm thick 1.2.1Mtr67.9867.98150.0FalseNoneNoneFalseNoneFalse10197.00
269292484710Nonecode12825 mm dia 2 mm thick 1.2.2Mtr80.3480.34200.0FalseNoneNoneFalseNoneFalse16068.00
269292584710Nonecode129Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 19/20 mm dia 2 mm thick 1.3.1Mtr70.0470.04100.0FalseNoneNoneFalseNoneFalse7004.00
269292684710Nonecode130Do- 25 mm dia 2 mm thick 1.3.2Mtr81.3781.37150.0FalseNoneNoneFalseNoneFalse12205.50
269292784710Nonecode131Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm as required. 25 mm 1.8.2Mtr36.0536.0520.0FalseNoneNoneFalseNoneFalse721.00
269292884710Nonecode132Supplying PVC flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely. 20 mm 1.9.1Mtr19.5719.5710.0FalseNoneNoneFalseNoneFalse195.70
269292984710Nonecode133Do- 25 mm 1.9.2Mtr22.6622.6630.0FalseNoneNoneFalseNoneFalse679.80
269293084710Nonecode134Supplying And Fixing Metal Fan Box with Round Hook.No120.51120.5120.0FalseNoneNoneFalseNoneFalse2410.20
269293184710Nonecode135Supplying and wiring adopting loop system in existing PVC Conduit / casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box 2.2.1No277.07277.0730.0FalseNoneNoneFalseNoneFalse8312.10
269293284710Nonecode136Do- Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box 2.2.2No390.37390.3770.0FalseNoneNoneFalseNoneFalse27325.90
269293384710Nonecode137Do- Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box 2.2.3No571.65571.6530.0FalseNoneNoneFalseNoneFalse17149.50
269293484710Nonecode138Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:2010 1.5 mm2 2.3.2Mtr26.7826.781000.0FalseNoneNoneFalseNoneFalse26780.00
269293584710Nonecode139Do- 2.5 mm2 2.3.3Mtr43.2643.261200.0FalseNoneNoneFalseNoneFalse51912.00
269293684710Nonecode140Do- 4 mm2 2.3.4Mtr64.8964.89900.0FalseNoneNoneFalseNoneFalse58401.00
269293784710Nonecode141Do- 6 mm2 2.3.5Mtr94.7694.7620.0FalseNoneNoneFalseNoneFalse1895.20
269293884710Nonecode142Do- 10 mm2 2.3.6Mtr172.01172.015.0FalseNoneNoneFalseNoneFalse860.050
269293984710Nonecode143Do- 16 mm2 2.3.7Mtr327.54327.545.0FalseNoneNoneFalseNoneFalse1637.70
269294084710Nonecode144Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS- 694:1990. 3C x 4 mm2 2.6.2Mtr173.04173.04300.0FalseNoneNoneFalseNoneFalse51912.00
269294184710Nonecode145Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 1-2 Way 3.3.1No106.09106.094.0FalseNoneNoneFalseNoneFalse424.360
269294284710Nonecode146Do- 3 Way 3.3.2No127.72127.724.0FalseNoneNoneFalseNoneFalse510.880
269294384710Nonecode147Do- 4-5 Way 3.3.3No141.11141.116.0FalseNoneNoneFalseNoneFalse846.660
269294484710Nonecode148Do- 6 Way 3.3.4No178.19178.196.0FalseNoneNoneFalseNoneFalse1069.140
269294584710Nonecode149Do- 8 Way 3.3.5No225.57225.5715.0FalseNoneNoneFalseNoneFalse3383.550
269294684710Nonecode150Do- 10-12 Way 3.3.6No268.83268.8318.0FalseNoneNoneFalseNoneFalse4838.940
269294784710Nonecode151Do- 18 Way 3.3.8No349.17349.1712.0FalseNoneNoneFalseNoneFalse4190.040
269294884710Nonecode152Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-2 Way 3.4.1No142.14142.142.0FalseNoneNoneFalseNoneFalse284.280
269294984710Nonecode153Do- 6 Way 3.4.4No226.6226.62.0FalseNoneNoneFalseNoneFalse453.20
269295084710Nonecode154Do- 8 Way 3.4.5No268.83268.832.0FalseNoneNoneFalseNoneFalse537.660
269295184710Nonecode155Do- 10-12 Way 3.4.6No328.57328.572.0FalseNoneNoneFalseNoneFalse657.140
269295284710Nonecode156Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module 3.5.1No141.11141.116.0FalseNoneNoneFalseNoneFalse846.660
269295384710Nonecode157Do- 3 Module 3.5.2No165.83165.834.0FalseNoneNoneFalseNoneFalse663.320
269295484710Nonecode158Do- 4 Module 3.5.3No180.25180.256.0FalseNoneNoneFalseNoneFalse1081.50
269295584710Nonecode159Do- 6 Module 3.5.4No241.02241.028.0FalseNoneNoneFalseNoneFalse1928.160
269295684710Nonecode160Do- 8 Module 3.5.5No292.52292.5217.0FalseNoneNoneFalseNoneFalse4972.840
269295784710Nonecode161Do- 10-12 Module 3.5.6No354.32354.3220.0FalseNoneNoneFalseNoneFalse7086.40
269295884710Nonecode162Do- 18 Module 3.5.8No470.71470.7112.0FalseNoneNoneFalseNoneFalse5648.520
269295984710Nonecode163Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch 3.6.1No105.06105.06260.0FalseNoneNoneFalseNoneFalse27315.60
269296084710Nonecode164Do- 6A Two Way Switch 3.6.2No170.98170.984.0FalseNoneNoneFalseNoneFalse683.920
269296184710Nonecode165Do- 6A Three Way socket 3.6.3No176.13176.1380.0FalseNoneNoneFalseNoneFalse14090.40
269296284710Nonecode166Do- Stepped Fan Regulator Two Module 3.6.4No367.71367.7120.0FalseNoneNoneFalseNoneFalse7354.20
269296384710Nonecode167Do- 16A One Way Switch 3.6.7No185.4185.44.0FalseNoneNoneFalseNoneFalse741.60
269296484710Nonecode168Do- 6A Bell Push 3.6.8No182.31182.312.0FalseNoneNoneFalseNoneFalse364.620
269296584710Nonecode169Do- 32A DP Switch 3.6.9No335.78335.7810.0FalseNoneNoneFalseNoneFalse3357.80
269296684710Nonecode170Do- 6/16A Universal Socket 3.6.10No243.08243.0810.0FalseNoneNoneFalseNoneFalse2430.80
269296784710Nonecode171Do- TV/Telephone Socket 3.6.11No160.68160.682.0FalseNoneNoneFalseNoneFalse321.360
269296884710Nonecode172Do- RJ45/I.O Outlet Cat-6 3.6.12No347.11347.1120.0FalseNoneNoneFalseNoneFalse6942.20
269296984710Nonecode173Supplying and fixing of metal clad industrial plugs and sockets. 2pole+earth 250V PLUG 32A 3.13.2No564.52564.524.0FalseNoneNoneFalseNoneFalse2258.080
269297084710Nonecode174Fabrication, Supplying, Erection, Testing and Commissioning of ms long Polygon high mast with Single/Multiple telescopic sections having, (minimum overlap distance of 1.5 times of top section) thickness as per BSEN 10025 grades 355 JO/ASTM A572-50 steel sheet plate for shaft suitable to withstand a wind velocity of 47 m/s as per IS 875 part 3(as per GA Drawing). Base plate as per IS 2062/ASTM A572- 50. The mast shall be Galvanized in single Hot- dip as per BSEN ISO 1461/ASTM A123 with an average 70 microns as per IS 2629, and welded as per BS 5135 Single L-Seam joint The mast shall have 2 Way head frame with die cast LM-6 pulleys, stainless steel axle, Phosphorus Bronze bearing bush press-fitted with separate guides for 2 runs of 5 mm dia, stainless steel wire rope of AISI 304grade 7/19-core, (Factor of Safety as per TR no-7). 2.5 mm2 EPR insulated PCP sheathed trailing power cable housed inside the bottom shaft of mast with door having locking arrangement The mast shall have manual/power tool (Suitable reversible geared motor operating on 230/415V, 50Hz, shall be provide above 15 Mtr mast) The mast shall have lantern of 2 segments, suitable dia with max load carrying capacity as per IS 1239. The mast shall be erected on existing RCC footing. The mast shall be supplied with 3 mm thick template, lightning arrester of 1.2m length galvanized pipe with top arrow fitted on top of the head frame cover and GLS type aviation twin l A fitting with wiring complete. (excluding foundation) as per technical data. 16 m - Top 150 mm and Bottom 410 mmNo200850.0200850.01.0FalseNoneNoneFalseNoneFalse200850.00
269297184710Nonecode175Fabricating, supplying and erection of ... ms long hot dip Galvanized Octagonal hot dip Pole with BSEN 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for m Pole in single section and single joint welded as per IS 9595/IS10178 AWS having dimensions bottom ..... mm , top. mm with 3 mm thick, suitable base plate and 4Nos of long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc., (excluding foundation) as per drawing appended. 7 m - Top 70 mm and Bottom 130 mm dia 4.2.5No13905.013905.010.0FalseNoneNoneFalseNoneFalse139050.00
269297284710Nonecode176Supplying, and fixing of Hot dip Galvanized M.S.Bracket suitable for out door luminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete. Single Arm Bracket with 1500 mm Standard 40/50 mm dia 4.6.2No2163.02163.08.0FalseNoneNoneFalseNoneFalse17304.00
269297384710Nonecode177Do- Double Arm Bracket with 1500 mm Standard 40/50 mm dia 4.6.5No3399.03399.02.0FalseNoneNoneFalseNoneFalse6798.00
269297484710Nonecode178Supplying fully automatic star-delta starter unit push button type with suitable wires, 3 contactors, one adjustable thermal timer mounted on a common base plate held in steel enclosure for use on 400/440 V 3 phase and wired after fixing to the existing wooden board for motor. 5.2.1No7678.657678.651.0FalseNoneNoneFalseNoneFalse7678.650
269297584710Nonecode179Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution) 200 A 5.12.4No15706.4715706.471.0FalseNoneNoneFalseNoneFalse15706.470
269297684710Nonecode180Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP 5.18.1No427.45427.4512.0FalseNoneNoneFalseNoneFalse5129.40
269297784710Nonecode181Do- 6-32 A DP 5.18.4No761.17761.178.0FalseNoneNoneFalseNoneFalse6089.360
269297884710Nonecode182Do- 6-32 A TPN 5.18.7No1768.511768.516.0FalseNoneNoneFalseNoneFalse10611.060
269297984710Nonecode183Do- 40 A TPN 5.18.8No3135.323135.324.0FalseNoneNoneFalseNoneFalse12541.280
269298084710Nonecode184Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. II - Double Door 8 Way SP & N 5.19.8No1909.621909.622.0FalseNoneNoneFalseNoneFalse3819.240
269298184710Nonecode185Do- 6 Way TP & N 5.19.12No5088.25088.22.0FalseNoneNoneFalseNoneFalse10176.40
269298284710Nonecode186Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short- Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR Pole 100 A 25 kA 5.15.9No8741.618741.614.0FalseNoneNoneFalseNoneFalse34966.440
269298384710Nonecode187Do- 125 A 25 kA 5.15.10No10651.2310651.231.0FalseNoneNoneFalseNoneFalse10651.230
269298484710Nonecode188Do- 250 A 25 kA 5.15.13No22032.7322032.731.0FalseNoneNoneFalseNoneFalse22032.730
269298584710Nonecode189Supplying and fixing of Shunt trip suitable for MCCB.CBCT 5.16No1754.091754.096.0FalseNoneNoneFalseNoneFalse10524.540
269298684710Nonecode190Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. 5.21No9532.659532.652.0FalseNoneNoneFalseNoneFalse19065.30
269298784710Nonecode191Supplying, fixing and wiring 3 Phase Digital Ammeter / Voltmeter 5.29No1467.751467.752.0FalseNoneNoneFalseNoneFalse2935.50
269298884710Nonecode192Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. 5.38No530.45530.458.0FalseNoneNoneFalseNoneFalse4243.60
269298984710Nonecode193Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 100 A 4 x 30 x 6 mm Aluminium Strips 5.40.1Mtr2538.952538.951.0FalseNoneNoneFalseNoneFalse2538.950
269299084710Nonecode194Do- 250 A 4 x 30 x 10 mm Aluminium Strips 5.40.2Mtr3538.053538.052.0FalseNoneNoneFalseNoneFalse7076.10
269299184710Nonecode195Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40 x 40 x 6 mm 5.41.1Mtr314.15314.158.0FalseNoneNoneFalseNoneFalse2513.20
269299284710Nonecode196Do- 50 x 100 x 50 x 6 mm C channel 5.41.4Mtr778.68778.684.0FalseNoneNoneFalseNoneFalse3114.720
269299384710Nonecode197Fabricating supplying and mounting MS box made out SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWG 5.42.1Sq CM0.520.5260000.0FalseNoneNoneFalseNoneFalse31200.00
269299484710Nonecode198Do- 16 SWGSq CM0.440.44100000.0FalseNoneNoneFalseNoneFalse44000.00
269299584710Nonecode199Supplying, fixing and wiring Automatic Power Factor controller circuit unit fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three phase LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect/ disconnect banks, with automatic recognition or with standard programs. 5.39No22289.222289.21.0FalseNoneNoneFalseNoneFalse22289.20
269299684710Nonecode200Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries like induction motor. 5.37Kvar494.4494.420.0FalseNoneNoneFalseNoneFalse9888.00
269299784710Nonecode201Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. 6.1No1536.761536.764.0FalseNoneNoneFalseNoneFalse6147.040
269299884710Nonecode202Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 12" Sweep (300 mm) 6.2.1No3058.073058.074.0FalseNoneNoneFalseNoneFalse12232.280
269299984710Nonecode203Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire. 13.14No506.76506.768.0FalseNoneNoneFalseNoneFalse4054.080
269300084710Nonecode204Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48" Sweep (1200 mm) Regular model 6.3.1No3073.523073.5210.0FalseNoneNoneFalseNoneFalse30735.20
269300184710Nonecode205Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/-10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2 year manufacturer Warranty. (BLDC fans). 48" Sweep 5 Star (1200 mm) 6.4.1No2757.312757.312.0FalseNoneNoneFalseNoneFalse5514.620
269300284710Nonecode206Supplying wall mounting fan suitable to operate at single- phase 230v AC. supply. 400 mm Sweep 6.5.2No3308.363308.364.0FalseNoneNoneFalseNoneFalse13233.440
269300384710Nonecode207Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. 13.10No176.13176.1316.0FalseNoneNoneFalseNoneFalse2818.080
269300484710Nonecode208Supplying of .. TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 V with hermetically sealed inverter compressor with air cooled condenser, latest R410A / R-32 refrigerant fan motor, start & run capacitors, relay & over load protector internal unit, with one indoor & one outdoor unit The condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube. suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit. 5 star 2 Ton capacity 6.8.6No69420.9769420.972.0FalseNoneNoneFalseNoneFalse138841.940
269300584710Nonecode209Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette type A/C. 6.12No3270.253270.252.0FalseNoneNoneFalseNoneFalse6540.50
269300684710Nonecode210Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit Leak testing oil and gas charging for additional piping length of tube. 6.13.1m1595.471595.475.0FalseNoneNoneFalseNoneFalse7977.350
269300784710Nonecode211Supplying & filling refrigerant (F- 22/F/12) for air conditioning equipment's. Which includes the labour & Nitrogen gas for pressure and leak testing. 6.19Kgs623.15623.152.0FalseNoneNoneFalseNoneFalse1246.30
269300884710Nonecode212Extra for Fabrication supply and fixing of Stand fabricated using slotted angle /L angle of size 6mm x 50mm for mounting out door/indoor A.C. unit/ Batteries. 6.22No4951.214951.212.0FalseNoneNoneFalseNoneFalse9902.420
269300984710Nonecode213Supplying vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside Fiber body outside, filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate. 2kW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting. 5 Star With Fibre body 25 L 7.2.1No12286.8712286.872.0FalseNoneNoneFalseNoneFalse24573.740
269301084710Nonecode214Erection charges for fixing a wall mounting electric geysers using bolts, flat at one end nut and washers at the other end for through bolts and nuts and washers with 150x450x600mm back plate and wiring complete with 15A 3 pin top. upto 30 Litres 13.15.1No683.92683.922.0FalseNoneNoneFalseNoneFalse1367.840
269301184710Nonecode215Supplying, installation, testing and commissioning of solar hot water heater comprising of high quality Evacuated Glass Tube (EGT) with absorber coating collector of size 58 x 1800 mm. Inner tank Material- Stainless steel 304-L Grade with Aluminium Stucco cladding made of High quality PUF insulation to minimizes heat loss and hold water Temperature upto 72 Hrs...with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. Fitted with Sacrificial Anode. 300 L 29 nos Tubes 7.4.3No53073.8453073.841.0FalseNoneNoneFalseNoneFalse53073.840
269301284710Nonecode216Supplying and drawing UTP-CAT 6E LAN cable. 8.1Mtr39.1439.141500.0FalseNoneNoneFalseNoneFalse58710.00
269301384710Nonecode217Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. 2Pair 8.2.2Mtr21.6321.63600.0FalseNoneNoneFalseNoneFalse12978.00
269301484710Nonecode218Supplying & Fixing of switch mounting rack with power manager & Cable manager. 12U with 450mm depth 8.4.4No9100.059100.051.0FalseNoneNoneFalseNoneFalse9100.050
269301584710Nonecode219Supplying fixing of 48 port 10/100 Switch 8.9.4No15450.015450.01.0FalseNoneNoneFalseNoneFalse15450.00
269301684710Nonecode220Supplying & Fixing of ... ms Cat 6 Patch Cable. 1 m 8.11.1No230.72230.7220.0FalseNoneNoneFalseNoneFalse4614.40
269301784710Nonecode221Supplying & Fixing of Patch panel for LAN cabling 48 Port 10/100 patch panel 8.12.1No14543.614543.61.0FalseNoneNoneFalseNoneFalse14543.60
269301884710Nonecode222Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination. 10 Pair 8.13.1No355.35355.352.0FalseNoneNoneFalseNoneFalse710.70
269301984710Nonecode223Supplying, installing, testing and commissioning of Diesel Generator set with following specifications. Power rating as per standard reference condition as per BS 5514/ISO 3046/ ISO 8528 & IS 1002/ISO 3046 Generator set specifications. 62.5KVA/50kw 10.1.7 (Detailed Specification enclosed seperately)Set660303.13660303.131.0FalseNoneNoneFalseNoneFalse660303.130
269302084710Nonecode224Supply, Erection, testing and commissioning of AMF panel suitable for DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for A 4 pole contactor for alternator with thermal O/L relay,..... A 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, ....capacity bypass switch and frequency sensing, PCC 1301controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ kVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMF module by pass Mode, Battery charger unit with inbuilt Auto/Manual and Flat/Boost facility. The complete set shall have sufficient safety and adhere to NEC, NBC 2016, IEC, CPWD specifications, PCB norms and KSGEI Acts and Rules. 10.2.3 62.5 KVANo80101.0480101.041.0FalseNoneNoneFalseNoneFalse80101.040
269302184710Nonecode225Supplying, erecting, testing and commissioning of voltage stabilizer suitable for 170 to 270 v input and load variation from no load to full load, with over load protection, spike suppression, operating at 00 C to 400 C. Range etc., complete. 5kVA Capacity 9.1.3No9955.989955.982.0FalseNoneNoneFalseNoneFalse19911.960
269302284710Nonecode226Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 5 kVA ON LINE UPS 9.3.3No70434.4970434.492.0FalseNoneNoneFalseNoneFalse140868.980
269302384710Nonecode227Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 75/80 AH capacity 9.5.6No10477.1610477.1612.0FalseNoneNoneFalseNoneFalse125725.920
269302484710Nonecode228Supplying of .....feet -PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 W 11.3.2No710.7710.740.0FalseNoneNoneFalseNoneFalse28428.00
269302584710Nonecode229Do- LED light fitting 1 x 4' - 36/40 W 11.3.3No1307.071307.0720.0FalseNoneNoneFalseNoneFalse26141.40
269302684710Nonecode230LED Down light: Supplying of recess mounting non integrated type LED down light...... W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power/COB with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 100 lumen per W, 120degree beam spread, life greater than 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED's are driven by HF electronic driver integrated in a separate control gear assembly., with PF greater than 0.95, power loss should less than 5% of lamp Wage, short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with2 years Warranty against any manufacturing defect working under standard electrical condition. 10-12W 11.4. 2No1307.071307.0716.0FalseNoneNoneFalseNoneFalse20913.120
269302784710Nonecode231Do- 15-18WNo1721.131721.138.0FalseNoneNoneFalseNoneFalse13769.040
269302884710Nonecode232Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @50/60Hz & Power factor greater than 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W 11.5.3No1363.721363.7212.0FalseNoneNoneFalseNoneFalse16364.640
269302984710Nonecode233Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 100 lumen per W, 120degree beam spread, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF greater than 0.95, power loss should less than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 1'x1' 24W. 11.6.2No3802.763802.768.0FalseNoneNoneFalseNoneFalse30422.080
269303084710Nonecode234Fixing all types and all capacities of 1'x4' / 2'x2' LED Light fittings indoor on the wall / ceiling / rafters / girders with necessary supporting frame, using 2310.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps. 13.19No504.7504.7104.0FalseNoneNoneFalseNoneFalse52488.80
269303184710Nonecode235Supply of LED pole mounting type post top lantern with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/ clear glass material, delivering superior light outputRated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss- wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/1 EC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB LED Efficiency greater than 1301m/w, nominal er should have in- house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Post Top Lantern with 15/20 W 11.7. 1No7129.667129.664.0FalseNoneNoneFalseNoneFalse28518.640
269303284710Nonecode236Fixing charges of post top/ Gate/ Garden fitting /LED on the existing CI/ GI or any other pipe using required size of reducer, wiring using suitable wires. 13.6No203.94203.944.0FalseNoneNoneFalseNoneFalse815.760
269303384710Nonecode237Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with........W System Power consumption. LEDEfficiencygreater than1301m/w, nominal CRI greater than 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working underNo9125.89125.810.0FalseNoneNoneFalseNoneFalse91258.00
269303484710Nonecode238Do- LED Streetlight 120 W. 11.8.5No10361.810361.86.0FalseNoneNoneFalseNoneFalse62170.80
269303584710Nonecode239Supplying and Fixing of........mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires. Using 32mm dia G.I.Pipe. 13.1.2No1076.351076.356.0FalseNoneNoneFalseNoneFalse6458.10
269303684710Nonecode240Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate / clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System Power consumption. LED Efficiency greater than 1301m/w, nominal CRI greater than 75. Luminaire manufacturer should have in- house facility. LED Floodlight 100WNo9770.589770.588.0FalseNoneNoneFalseNoneFalse78164.640
269303784710Nonecode241Do- LED Floodlight 200W 11.9.6No19138.4319138.4310.0FalseNoneNoneFalseNoneFalse191384.30
269303884710Nonecode242Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. 13.5No166.86166.8618.0FalseNoneNoneFalseNoneFalse3003.480
269303984710Nonecode243Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell 12.2.1No253.38253.382.0FalseNoneNoneFalseNoneFalse506.760
269304084710Nonecode244Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia. 12.56No3615.33615.38.0FalseNoneNoneFalseNoneFalse28922.40
269304184710Nonecode245Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40 mm dia 2.9 mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400 mm with a cast iron cover. The earth electrode shall have staggered holes of 12 mm dia and the electrode should be covered 150 mm all- round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. 12.57No4383.684383.684.0FalseNoneNoneFalseNoneFalse17534.720
269304284710Nonecode246Supply and fixing GI/Copper strips for grounding connections, using necessary fixing materials as required. 25 x 6 mm GI strip 12.58.3Mtr131.84131.8440.0FalseNoneNoneFalseNoneFalse5273.60
269304384710Nonecode247Do- 25 x 3 mm Copper strip 12.58.7Mtr587.1587.120.0FalseNoneNoneFalseNoneFalse11742.00
269304484710Nonecode248Do- 600 x 600 x 3 mm Copper plate 12.58.11No7643.637643.634.0FalseNoneNoneFalseNoneFalse30574.520
269304584710Nonecode249Distribution Transformer - 3 Phase, 11kV/433V - Stacked CRGO Core with Oil as per IS-1180 (Part-1): 2014 CABLE ENTRY TYPE 100 kVA, Aluminium Wdg, Star 2 (5 Star) 12.16No232343.28232343.281.0FalseNoneNoneFalseNoneFalse232343.280
269304684710Nonecode250LT Protection Kit (Dwg No. BESCOM/GM/QS&S/10 Dtd 24.11.2018) 17.01No2083.692083.691.0FalseNoneNoneFalseNoneFalse2083.690
269304784710Nonecode251LT Distribution Box for 100 kVA DTC with MCCB's (Sheet Metal) (Dwg No. BESCOM/GM/QS&S/58 Dtd 24.11.2018) 18.01No23366.5823366.581.0FalseNoneNoneFalseNoneFalse23366.580
269304884710Nonecode25211 kV, 200 Amps Single Break GOS (Dwg No. BESCOM /GM / QS&S / 23 Dtd 24.11.2018) 24.01No9733.59733.51.0FalseNoneNoneFalseNoneFalse9733.50
269304984710Nonecode253Fixing of GOS including wiring (11 kV Single Break 200 Amps) 13.02Set1137.121137.121.0FalseNoneNoneFalseNoneFalse1137.120
269305084710Nonecode2541.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS- 3975 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm) 32.05Kms146097.26146097.260.4FalseNoneNoneFalseNoneFalse58438.9040
269305184710Nonecode255Do- 25 Sqmm, 3.5 Core, (12 GI Strips - 4 x 0.8 mm) 32.07Kms143735.47143735.470.6FalseNoneNoneFalseNoneFalse86241.2820
269305284710Nonecode256Do- 70 Sqmm, 3.5 Core, (18 GI Strips - 4 x 0.8 mm) 32.13Kms327449.36327449.360.3FalseNoneNoneFalseNoneFalse98234.8080
269305384710Nonecode257Do- 95 Sqmm, 3.5 Core, (21 GI Strips - 4 x 0.8 mm) 32.14Kms384411.45384411.450.2FalseNoneNoneFalseNoneFalse76882.290
269305484710Nonecode258Laying LTUG cable of 2.5 to 25 Sqmm (Single/3.5/4 Core) 20.05Kms1222.611222.611.0FalseNoneNoneFalseNoneFalse1222.610
269305584710Nonecode259Laying LTUG cable of 35 to 95 Sqmm (3.5/4 Core) 20.06Kms2456.552456.550.5FalseNoneNoneFalseNoneFalse1228.2750
269305684710Nonecode260Heavy Duty Copper Terminal Long Barrel 25 Sqmm Copper Terminal, Apprx Wt: 11 Gm 59.01No27.8127.8160.0FalseNoneNoneFalseNoneFalse1668.60
269305784710Nonecode261Do- 50 Sqmm Copper Terminal, Apprx Wt: 26 Gm 59.03No59.7459.7440.0FalseNoneNoneFalseNoneFalse2389.60
269305884710Nonecode262Do- 70 Sqmm Copper Terminal, Apprx Wt: 38 Gm 59.04No91.6791.6732.0FalseNoneNoneFalseNoneFalse2933.440
269305984710Nonecode263Do- 95 Sqmm Copper Terminal, Apprx Wt: 58 Gm 59.05No132.87132.8716.0FalseNoneNoneFalseNoneFalse2125.920
269306084710Nonecode264Supply of 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975. 95 Sqmm, (54 GI Wires - 2.5 mm Dia) 36.01Kms916355.98916355.980.3FalseNoneNoneFalseNoneFalse274906.7940
269306184710Nonecode265Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff HT Cable 3x95 to 150 SqmmKms63161.6663161.660.2FalseNoneNoneFalseNoneFalse12632.3320
269306284710Nonecode266Supply of 11 kV, Jointing & Cable Termination Kit as per IS-13573 Heat Shrinkable Type Transition Jointing Kit for XLPE Cable 3x95 Sqmm 45.01Set10553.3810553.382.0FalseNoneNoneFalseNoneFalse21106.760
269306384710Nonecode267Cable Joint and wiring HT UG Cable Heat shrinkable Straight Through Joint 3x95 to 3x150 SqmmSet2933.442933.442.0FalseNoneNoneFalseNoneFalse5866.880
269306484710Nonecode268Supply of 11 kV, Jointing & Cable Termination Kit as per IS-13573 Heat Shrinkable Indoor Type Cable Termination Kit for XLPE Cable 3x95 Sqmm 45.04Set3856.323856.325.0FalseNoneNoneFalseNoneFalse19281.60
269306584710Nonecode269Making and Fixing pot head for HT Cable only Heat shrinkable Type Terminations 3x95 to 3x150 Sqmm. 22.04Set2737.742737.745.0FalseNoneNoneFalseNoneFalse13688.70
269306684710Nonecode270Supply and fixing LT Current Transformer, 3.75 VA, Ring type as per IS-2705 Part- 1&2 CT Ratio - 50/5A, 0.5 Accuracy Class 56.05No917.73917.736.0FalseNoneNoneFalseNoneFalse5506.380
269306784710Nonecode271Supply of 11 kV HT Metering cubicle of different CT Ratio, Both side cable entry type with 3 CT & 3 PT, With Transparent Cover TTB, with 30x8 mm Copper Busbar, Modem & 2 No of Meters for 3 Phase 4 Wire Metering without Load Break Switch (HT Metering Box Fabricated out of 3 mm MS Sheet duly epoxy powder coated) as per revised Specification (Dwg No. BESCOM/GM/QS&S/-- Dtd 24.11.2018) 58.01Set250776.16250776.161.0FalseNoneNoneFalseNoneFalse250776.160
269306884710Nonecode272Erection of HT metering Cubicle on Platform. 8.01 as per detailed specification of BESCOMNo1899.321899.321.0FalseNoneNoneFalseNoneFalse1899.320
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17083317510000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17083317510000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17083317510000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17083317990000NoneNoneELIGIBILITYThe Bidders shall refer the Tender Notification for all the Terms and conditions and agree to abide by themNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneShould be valid registered Class-I Contractors/Firms registered in KPWD / MES / CPWD.OthersRegistration Certificate
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Registration Certificate
NoneNoneNoneNoneWork-done Certificate for having satisfactorily completed as a prime contractor at least one similar nature of work of not less than 50% of amount put to tender i.e., Rs. 357.20 Lakhs in last previous five years in any of the Government / Public Sector Undertaking i.e (2018-19, 2019-20, 2020-21, 2021-22 & 2022-23)OthersWorkdone certificate - Similar work
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Workdone Certificate
NoneNoneNoneNoneExecuted in any one financial year during the last five years (i.e., 2018-19, 2019-20, 2020-21, 2021-22 & 2022-23) the following minimum quantities of work in any of the Government / Public Sector Undertaking. Reinforced Cement Concrete : 951.00 Cum, TMT / Mild Steel : 85.00 Tonnes, Cement Paver block: 5645.00 Sqm, Solid Concrete Block: 849.00 Sqm OR Burnt Brick Masonry: 196.00 CumOthersWorkdone certificate - Minimum Quantities
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Workdone certificate
NoneNoneNoneNoneShould have achieved in at least two financial years a minimum annual financial turnover (in all classes of Civil works only) of not less than two times the amount put to tender out of during the last five financial years (2018-19, 2019-20, 2020-21, 2021-22 & 2022-23). ie, Rs. 1501.00 LakhsOthersProfit and Loss statement
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Profit and Loss statement
NoneNoneNoneNoneLiquid assets and availability of credit facilities of not less than 30% of the equivalent of the amount put to tender. ie, Rs. 226.00 LakhsOthersLine of Credit
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Letter of Credit
NoneNoneNoneNoneTenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender valueOthersBid Capacity
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Lost of ongoing works
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Registration CertificateTrueTechnical Bid
Workdone certificate - Similar workTrueTechnical Bid
Workdone certificate - Minimum QuantitiesTrueTechnical Bid
Profit and Loss statementTrueTechnical Bid
Letter of CreditTrueTechnical Bid
List of ongoing worksTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1708333506000
version0
createdDateNone
modifiedDateNone
blockNumberCivil Engineering Dept, BMTC Central Office, Shanthinagar TTMC building, K. H. Road
streetNone
cityBengaluru
stateKarnataka
pin560027
tenderRecallDTONone