2710198 | 85129 | None | code01 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m | Cum | 254.1 | 254.1 | 145.8 | False | None | None | False | None | False | 37047.78 | 0 |
2710199 | 85129 | None | code02 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 16.2 | False | None | None | False | None | False | 96344.64 | 0 |
2710200 | 85129 | None | code03 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 9080.51 | 9080.51 | 53.57 | False | None | None | False | None | False | 486442.9207 | 0 |
2710201 | 85129 | None | code04 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement
including cost of all materials, machinery, labour, cleaning, straightening,
cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification | Tonne | 82961.55 | 82961.55 | 1.56 | False | None | None | False | None | False | 129420.018 | 0 |
2710202 | 85129 | None | code05 | Fabricating, supplying and erecting Swaged tubular Pole of height ...m having three sections, and providing two coats of red oxide paint and finished with two coats of enamelled paint of approved quality and colour and M.S. base plate of suitable size welded at the bottom of the Pole(as per IS) and 40 mm dia GI/flexible PVC pipe of 1m length fitted to the heavy gauge polycarbonate control box including 5 Way connector of size 167 x 125 x 82 mm for 7.5M Pole/ 200 x 160 x 98 mm for remaining length of Pole with front opening cover, with locking arrangements and suitable capacity MCB/DP switch, The Pole shall be erected in cement concrete work (1:2:4) including excavation and refilling of planting depth of the Pole to the ground level and the coping CC shall be upto 0.6m above ground level as per IS2713-7. 10m (5m Hb,165.1 mm dia 4.85 mm thick x 3m Hm, 139.7 mm dia 4.50 mm thick x 2m Ht,114.3 mm dia 3.65 mm thick) as per IS 410 SP 47 | Each | 18021.15 | 18021.15 | 1.0 | False | None | None | False | None | False | 18021.15 | 0 |
2710203 | 85129 | None | code06 | Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4" dia telescopic M. S. pipe, with 2" dia1.5m long M.S.Bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 ms. M. S. tubular pole, with necessary two coats of painting, with all other accessories Single bracket 1.5 m. Length | Each | 1360.8 | 1360.8 | 4.0 | False | None | None | False | None | False | 5443.2 | 0 |
2710204 | 85129 | None | code07 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 4 mm2 | Mtr | 61.95 | 61.95 | 60.0 | False | None | None | False | None | False | 3717.0 | 0 |
2710205 | 85129 | None | code08 | Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood
plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws 32 mm dia 2.5 mm thick | Rmtr | 105.0 | 105.0 | 75.0 | False | None | None | False | None | False | 7875.0 | 0 |
2710206 | 85129 | None | code09 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS- 694:2010 4C x 6 mm2 | Mtr | 311.85 | 311.85 | 60.0 | False | None | None | False | None | False | 18711.0 | 0 |
2710207 | 85129 | None | code10 | Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required. 6 sqmm to 16 sqmm | Mtr | 11.88 | 11.88 | 10.0 | False | None | None | False | None | False | 118.8 | 0 |
2710208 | 85129 | None | code11 | Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7) | Mtr | 102.0 | 102.0 | 50.0 | False | None | None | False | None | False | 5100.0 | 0 |
2710209 | 85129 | None | code12 | Supplying and Fixing........mm dia class A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clA, bolts, nuts and wiring using suitable capacity wires Using 40mm dia G.I.Pipe | Mtr | 1374.45 | 1374.45 | 10.0 | False | None | None | False | None | False | 13744.5 | 0 |
2710210 | 85129 | None | code13 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to
IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access
street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ....... W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing
defect working under standard electrical conditions as mentioned above should be given by
LED manufacturer & Cree/Nichia/LED Floodlight 150W | Each | 11684.4 | 11684.4 | 6.0 | False | None | None | False | None | False | 70106.4 | 0 |
2710211 | 85129 | None | code14 | Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires | Each | 198.45 | 198.45 | 6.0 | False | None | None | False | None | False | 1190.7 | 0 |
2710212 | 85129 | None | code15 | Fixing of ..... A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling 15A to 63A TPST | Each | 271.95 | 271.95 | 2.0 | False | None | None | False | None | False | 543.9 | 0 |
2710213 | 85129 | None | code16 | Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour 32A | Each | 2041.2 | 2041.2 | 4.0 | False | None | None | False | None | False | 8164.8 | 0 |
2710214 | 85129 | None | code17 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws 8" x 6" x 1.5" | Each | 79.8 | 79.8 | 4.0 | False | None | None | False | None | False | 319.2 | 0 |
2710215 | 85129 | None | code18 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 16Amps | Each | 131.25 | 131.25 | 4.0 | False | None | None | False | None | False | 525.0 | 0 |
2710216 | 85129 | None | code19 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers 16 A | Each | 390.6 | 390.6 | 4.0 | False | None | None | False | None | False | 1562.4 | 0 |
2710217 | 85129 | None | code20 | Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947 | Each | 1246.35 | 1246.35 | 2.0 | False | None | None | False | None | False | 2492.7 | 0 |
2710218 | 85129 | None | code21 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure | Each | 1367.1 | 1367.1 | 2.0 | False | None | None | False | None | False | 2734.2 | 0 |
2710219 | 85129 | None | code22 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint 40 x 40 x 6 mm | Mtr | 288.75 | 288.75 | 3.25 | False | None | None | False | None | False | 938.4375 | 0 |
2710220 | 85129 | None | code23 | Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete | Mtr | 0.34 | 0.34 | 1050.0 | False | None | None | False | None | False | 357.0 | 0 |
2710221 | 85129 | None | code24 | Supplying and fixing Microprocessor Based Astronomical timer Switch with using necessary bolts, nuts and washers | Each | 4569.6 | 4569.6 | 1.0 | False | None | None | False | None | False | 4569.6 | 0 |
2710222 | 85129 | None | code25 | Supply of LED Streetlight luminaire with pressure die cast aluminiumhousing bodyforoptimalthermaldissipation. Lampcompartmentcomprisingof anti glarecleardiffuser with Injection moulded polycarbonate material, delivering superiorlightoutputRatedlifeBurningHrs50000hr@Lumen Maintenance of 70%,maximum light intensityshould be between60 degreesto 70 degrees.CCT 5500K, IP66 optical and electrical compartment & impact resistance ofcompleteluminaire IK08.PowerFactor 0.9with mains, Surge Protection- Min 5KV along with Over voltage/ Overload,shortcircuit/ miss-wiringprotection.Compatible for pole mounting with outer dia of 40mmto 50mm. Universal Voltage driver to operate wide voltagerange from 100V to270V50/60Hzapplication.CompliancetoIS10322/IEC 60598, LM 79&LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location withminimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire
manufacturershouldhavein-housefacilityaccreditedbyNABL/CPRI& any Government certified agency & Design&Developmentfacility certified by
ISO 9001:2008. Housing with supplier word mark/name shall be Engraved/
Embossingonthe die casthousing/Bodypart. Warrantyof 2 Years against any
manufacturingdefect working under standard electrical conditions as
mentioned above should be given by LED manufacturer & Cree/Nichia/
Lumileds/Osrammake LED Source. LEDStreetlight 90W | Each | 9303.0 | 9303.0 | 50.0 | False | None | None | False | None | False | 465150.0 | 0 |
2710223 | 85129 | None | code14 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) 0.00 to 50.00 Mtr | Rmtr | 388.5 | 388.5 | 100.0 | False | None | None | False | None | False | 38850.0 | 0 |
2710224 | 85129 | None | code26 | Supplying and Fixing 40 mm dia class A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clA, bolts, nuts and wiring using suitable capacity wires Using 40mm dia G.I.Pipe | Each | 1551.9 | 1551.9 | 50.0 | False | None | None | False | None | False | 77595.0 | 0 |
2710225 | 85129 | None | code12 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) 51.00 to 100.00 Mtr | Rmtr | 487.2 | 487.2 | 100.0 | False | None | None | False | None | False | 48720.0 | 0 |
2710226 | 85129 | None | code13 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) 101.00 to 150.00 Mtr | Rmtr | 517.65 | 517.65 | 100.0 | False | None | None | False | None | False | 51765.0 | 0 |
2710227 | 85129 | None | code14 | Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty | Mtr | 2029.65 | 2029.65 | 84.0 | False | None | None | False | None | False | 170490.6 | 0 |
2710228 | 85129 | None | code15 | Providing Submersible Pump Set of 150mm dia suitable for bore well and
confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt
Motor as per specifications, to work site as per necessary ammendments
and instructions of engineer incharge of work. 3.0HP | No | 29518.65 | 29518.65 | 1.0 | False | None | None | False | None | False | 29518.65 | 0 |
2710229 | 85129 | None | code16 | Providing, laying and jointing HDPE pipes of specified grade and
conforming to IS 4984-2016 with latest ammendments and conveying
to work site including loading and unloading at both destinations and
rolling and lowering into trenches, laying true to line and jointing of
pipes and specials with electrofusion welding, giving hydraulic test
as per relevant ISS with all lead and lifts including encasing the pipe
alround to a depth of not less than 15 cms. with soft gravel or selected
earth available from the excation, testing and commissioning. The
rate is exclusive of required specials and fittings wherever necessary
like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete
(Contractor will make his own arrangements for procuring water for
testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used.
For :HDPE PE 80 PN 6.0 HDPE Grade PE80-PN8.0,63mm dia | Rmtr | 229.95 | 229.95 | 100.0 | False | None | None | False | None | False | 22995.0 | 0 |
2710230 | 85129 | None | code17 | Labour charges for Erection, Electrification and commissioning of Pump
sets, including aligning and balancing of all items including supply and
erection of two pair of supporting clamps, bore well caps, cable clips and
water tight gland cable protectors, bolts, nuts, valve and gauges,tools and
equipments etc., involved in the job as per specifications, with necessary
tests as per specifications, with testing of as per instructions of engineer
incharge of work | Each | 6825.0 | 6825.0 | 1.0 | False | None | None | False | None | False | 6825.0 | 0 |
2710231 | 85129 | None | code18 | Supply and delivery at site Brand new best make PVC insulated cable ofFlat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990with ISI Mark and as per its latest amendments. 1x3x4 Sqm | Rmtr | 141.75 | 141.75 | 110.0 | False | None | None | False | None | False | 15592.5 | 0 |
2710232 | 85129 | None | code19 | Providing main connection from pole PVC insulated sheathed steel wire
cable in new trench as per IS 1554/ 1988 with latest amendments with
ISI mark from KPTCL pole to meter board unit | Rmtr | 141.75 | 141.75 | 30.0 | False | None | None | False | None | False | 4252.5 | 0 |
2710233 | 85129 | None | code20 | Supply and delivery at site of brand new best make non-return valve as
per IS 778/1984 with ISI Mark and as per its latest amendments 50 mm dia | Each | 1312.5 | 1312.5 | 1.0 | False | None | None | False | None | False | 1312.5 | 0 |
2710234 | 85129 | None | code21 | Supply, installing,testing and commissioning COMMON control panel
consisting of the following INCOMING:1 No set of Phase indicating
lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog
Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING
for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable
for respective HP 1 No. Electrcal Protection Like single Phase preventor,
under voltage over Volage, under current over current & dry run
protection suitable for the pump described above 1 no Indoor type NOTE:
1) DOL- Direct Online Starter, 2) S-D- Star Delta Starter etc. complete | Each | 10027.5 | 10027.5 | 1.0 | False | None | None | False | None | False | 10027.5 | 0 |
2710235 | 85129 | None | code22 | RCC hume pipe Circular pump house: Providing precast RCC Circular Hume pipe pump house with M.S door and RCC conical roof as per specification and drawings - Internal dia Mtr. 1200 mm & height of 2.5 Mtr. With Wall thickness 65mm etc. complete | Each | 17221.0 | 17221.0 | 1.0 | False | None | None | False | None | False | 17221.0 | 0 |
2710236 | 85129 | None | code23 | Medium Duty GI pipe of 40mm dia | Mtr | 512.4 | 512.4 | 6.0 | False | None | None | False | None | False | 3074.4 | 0 |
2710237 | 85129 | None | code24 | GI bend 40mm | Nos | 280.35 | 280.35 | 2.0 | False | None | None | False | None | False | 560.7 | 0 |
2710238 | 85129 | None | code25 | Medium Duty GI pipe of 20mm dia | Mtr | 257.25 | 257.25 | 2.0 | False | None | None | False | None | False | 514.5 | 0 |
2710239 | 85129 | None | code26 | GI Collar 40mm dia | Nos | 216.3 | 216.3 | 2.0 | False | None | None | False | None | False | 432.6 | 0 |
2710240 | 85129 | None | code27 | GI Collar 20mm dia | Mtr | 103.95 | 103.95 | 2.0 | False | None | None | False | None | False | 207.9 | 0 |
2710241 | 85129 | None | code28 | Providing GM gland cocks tested against hydraulic pressure of 20 Kg/m² with ISI mark. For 20 mm dia GM gland cocks | Each | 439.95 | 439.95 | 4.0 | False | None | None | False | None | False | 1759.8 | 0 |
2710242 | 85129 | None | code29 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark For 40 mm dia GM (Copper alloy) Gate valves | Each | 1575.0 | 1575.0 | 1.0 | False | None | None | False | None | False | 1575.0 | 0 |
2710243 | 85129 | None | code30 | Supply and delivery at site wrought middle steel (galvanized) GI plugs confirming to IS 1239-II, 1991 with latest amendments if any For 40 mm dia GI Plugs | Each | 184.8 | 184.8 | 2.0 | False | None | None | False | None | False | 369.6 | 0 |
2710244 | 85129 | None | code31 | Supply and delivery at site wrought middle steel (galvanized) GI union confirming to IS 1239-II, 1991 with latest amendments if any For 20 mm dia GI Union | Each | 135.45 | 135.45 | 2.0 | False | None | None | False | None | False | 270.9 | 0 |
2710245 | 85129 | None | code32 | Earth work in surface excavation by manual means for lowering & levelling the ground by chiselling and wedging in Hard rock for all works other than foundation & depth not exceeding 100 mm as per drawing and technical specifications, including setting out, barricading, caution lights, dressing of excavated surfaces, disposing off the excavated spalls/stuff & stacking the selected spall/ stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work | Cum | 185.85 | 185.85 | 55.26 | False | None | None | False | None | False | 10270.071 | 0 |
2710246 | 85129 | None | code33 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm and down size graded crushed coarse aggregates | Cum | 6288.45 | 6288.45 | 1.32 | False | None | None | False | None | False | 8300.754 | 0 |
2710247 | 85129 | None | code34 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5891.55 | 5891.55 | 2.35 | False | None | None | False | None | False | 13845.1425 | 0 |
2710248 | 85129 | None | code35 | Erection and positioning of RCC Hume pipe pump house/Cistern on size stone masory platform including transportation charges and handling,finishing with all necessary tools ,plants and materials etc.,complete as directed by the Engineer in charge of the work | Each | 1976.1 | 1976.1 | 1.0 | False | None | None | False | None | False | 1976.1 | 0 |
2710249 | 85129 | None | code36 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 63mm dia., 6 kg/sqcm & class 3 | Rmtr | 169.05 | 169.05 | 120.0 | False | None | None | False | None | False | 20286.0 | 0 |
2710250 | 85129 | None | code37 | Refilling available earth around trenches/pipelines, cables in layers not
exceeding 20 cms in depth, compacting each deposited layer by ramming after
watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour
complete as per specifications | Cum | 168.0 | 168.0 | 55.26 | False | None | None | False | None | False | 9283.68 | 0 |