2710063 | 85121 | None | code01 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the workIn all kinds of soils. Depth upto 1.50m (PWD DSR 2023-24 Vol-I Page No. 6 tem No. 1.6.1) | Cum | 508.2 | 508.2 | 189.0 | False | None | None | False | None | False | 96049.8 | 0 |
2710064 | 85121 | None | code02 | Cutting Asphalt /Concrete road surface using machine cutter for leakage pit with earth work excavation in all classifications of soil including all lead and lifts bailing out water with pumps including barricading, danger lighting etc., as per requirement and disposing of the excavated stuff as directed. After attending the leak, refilling the trench for 30 cm depth quarry dust above and around pipelines and balance with available earth in layers not exceeding 20 cms in depth, compacting Each deposited layer by ramming including watering and consolidation by mechanical means approved by Engineer Incharge. (Work to be carried out as per leak repair manual and the rate includes hire charges of dewatering Pump, tractor, Jeep with all kinds of Labour in a Complete manner). (PWD SR 2023-24 Vol - V Page No. 48 item no. 3.3) | Cum | 1214.85 | 1214.85 | 4.5 | False | None | None | False | None | False | 5466.825 | 0 |
2710065 | 85121 | None | code03 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work (PWD DSR 2023-24 Vol-I Page No. 8 tem No. 1.12) | Cum | 99.75 | 99.75 | 211.5 | False | None | None | False | None | False | 21097.125 | 0 |
2710066 | 85121 | None | code04 | Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 8.0 | Rmtr | 229.95 | 229.95 | 50.0 | False | None | None | False | None | False | 11497.5 | 0 |
2710067 | 85121 | None | code05 | Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 90 mm dia Coil shall be used. For :HDPE PE 80 PN 8.0 | Rmtr | 401.1 | 401.1 | 50.0 | False | None | None | False | None | False | 20055.0 | 0 |
2710068 | 85121 | None | code06 | Refilling available earth around trenches/pipelines, cables in layers not
exceeding 20 cms in depth, compacting each deposited layer by ramming after
watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour
complete as per specifications | Cum | 168.0 | 168.0 | 405.0 | False | None | None | False | None | False | 68040.0 | 0 |
2710069 | 85121 | None | code07 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing
and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved
type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving Necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 75mm dia., 6 kg/sqcm & class 3 | Rmtr | 231.0 | 231.0 | 300.0 | False | None | None | False | None | False | 69300.0 | 0 |
2710070 | 85121 | None | code08 | Supply of PPR Ball Valve Plastic (Heavy Body) confirming to IS 15801-2008 and DIN Standard 8077/8092 | Each | 945.0 | 945.0 | 15.0 | False | None | None | False | None | False | 14175.0 | 0 |
2710071 | 85121 | None | code09 | Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction | Cum | 110.25 | 110.25 | 413.2 | False | None | None | False | None | False | 45555.3 | 0 |
2710072 | 85121 | None | code10 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work | Cum | 497.7 | 497.7 | 172.5 | False | None | None | False | None | False | 85853.25 | 0 |
2710073 | 85121 | None | code11 | Construction of Granular Sub-Base of required grading as per design mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401. For For Grading -II Material m3 | Cum | 2553.6 | 2553.6 | 87.0 | False | None | None | False | None | False | 222163.2 | 0 |
2710074 | 85121 | None | code12 | Plain Cement Pavement Quality M30 grade Concrete (RMC) with OPC & GGBS laid without Paver Construction of un-reinforced plain cement concrete pavement using RMC M-30 grade with OPC @ 270 kg/m3 and GGBS@ 90 kg/m3 (75:25 proportion) as per approved mix design procedure and thickness as per design, over a prepared sub base. The superplastisiser confirming to IS 9103-1999 Reaffirmed-2008 Coarse aggregates and Fine aggregate confirming to IS:383-2016, transported to site, laid in approved fixed side form work (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the form work). Spreading the concrete with shovels, rackers and compacted using needle, suitable plate vibrator and finished in a continuous operation including provision of separation membrane and Hessian cloth finishing to lines and grades complete including cost of all materials, labour, all lead & lift, loading charges as per specification & direction of Engineer - incharge of the work. (Groove cutting shall be paid seperately) | Cum | 7112.7 | 7112.7 | 155.25 | False | None | None | False | None | False | 1104246.675 | 0 |
2710075 | 85121 | None | code13 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 4 mm2 | Mtr | 61.95 | 61.95 | 120.0 | False | None | None | False | None | False | 7434.0 | 0 |
2710076 | 85121 | None | code14 | Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood
plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws 32 mm dia 2.5 mm thick | Rmtr | 105.0 | 105.0 | 120.0 | False | None | None | False | None | False | 12600.0 | 0 |
2710077 | 85121 | None | code15 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS- 694:2010 4C x 6 mm2 | Mtr | 311.85 | 311.85 | 120.0 | False | None | None | False | None | False | 37422.0 | 0 |
2710078 | 85121 | None | code16 | Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required. 6 sqmm to 16 sqmm | Mtr | 11.88 | 11.88 | 120.0 | False | None | None | False | None | False | 1425.6 | 0 |
2710079 | 85121 | None | code17 | Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7) | Mtr | 102.0 | 102.0 | 120.0 | False | None | None | False | None | False | 12240.0 | 0 |
2710080 | 85121 | None | code18 | Supplying and Fixing........mm dia class A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clA, bolts, nuts and wiring using suitable capacity wires Using 40mm dia G.I.Pipe | Mtr | 1374.45 | 1374.45 | 60.0 | False | None | None | False | None | False | 82467.0 | 0 |
2710081 | 85121 | None | code19 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to
IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access
street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ....... W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility
certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved /
Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing
defect working under standard electrical conditions as mentioned above should be given by
LED manufacturer & Cree/Nichia/LED Floodlight 150W | Each | 11684.4 | 11684.4 | 36.0 | False | None | None | False | None | False | 420638.4 | 0 |
2710082 | 85121 | None | code20 | Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires | Each | 198.45 | 198.45 | 36.0 | False | None | None | False | None | False | 7144.2 | 0 |
2710083 | 85121 | None | code21 | Fixing of ..... A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling 15A to 63A TPST | Each | 271.95 | 271.95 | 12.0 | False | None | None | False | None | False | 3263.4 | 0 |
2710084 | 85121 | None | code22 | Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour 32A | Each | 2041.2 | 2041.2 | 24.0 | False | None | None | False | None | False | 48988.8 | 0 |
2710085 | 85121 | None | code23 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws 8" x 6" x 1.5" | Each | 79.8 | 79.8 | 24.0 | False | None | None | False | None | False | 1915.2 | 0 |
2710086 | 85121 | None | code24 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 16Amps | Each | 131.25 | 131.25 | 24.0 | False | None | None | False | None | False | 3150.0 | 0 |
2710087 | 85121 | None | code25 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers 16 A | Each | 390.6 | 390.6 | 24.0 | False | None | None | False | None | False | 9374.4 | 0 |
2710088 | 85121 | None | code26 | Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947 | Each | 1246.35 | 1246.35 | 12.0 | False | None | None | False | None | False | 14956.2 | 0 |
2710089 | 85121 | None | code27 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure | Each | 1367.1 | 1367.1 | 12.0 | False | None | None | False | None | False | 16405.2 | 0 |
2710090 | 85121 | None | code28 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint 40 x 40 x 6 mm | Mtr | 288.75 | 288.75 | 19.5 | False | None | None | False | None | False | 5630.625 | 0 |
2710091 | 85121 | None | code29 | Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete | Mtr | 0.34 | 0.34 | 6300.0 | False | None | None | False | None | False | 2142.0 | 0 |
2710092 | 85121 | None | code30 | Supplying and fixing Microprocessor Based Astronomical timer Switch with using necessary bolts, nuts and washers | Each | 4569.6 | 4569.6 | 6.0 | False | None | None | False | None | False | 27417.6 | 0 |
2710093 | 85121 | None | code31 | Supply of LED Streetlight luminaire with pressure die cast aluminiumhousing bodyforoptimalthermaldissipation. Lampcompartmentcomprisingof anti glarecleardiffuser with Injection moulded polycarbonate material, delivering superiorlightoutputRatedlifeBurningHrs50000hr@Lumen Maintenance of 70%,maximum light intensityshould be between60 degreesto 70 degrees.CCT 5500K, IP66 optical and electrical compartment & impact resistance ofcompleteluminaire IK08.PowerFactor 0.9with mains, Surge Protection- Min 5KV along with Over voltage/ Overload,shortcircuit/ miss-wiringprotection.Compatible for pole mounting with outer dia of 40mmto 50mm. Universal Voltage driver to operate wide voltagerange from 100V to270V50/60Hzapplication.CompliancetoIS10322/IEC 60598, LM 79&LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location withminimized minimal tools. LED Light fixture with ........W System Power
consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire
manufacturershouldhavein-housefacilityaccreditedbyNABL/CPRI&
anyGovernmentcertifiedagency&Design&Developmentfacility certified by
ISO 9001:2008. Housing with supplier word mark/name shall be Engraved/
Embossingonthe die casthousing/Bodypart. Warrantyof 2 Years against any
manufacturingdefect working under standard electrical conditions as
mentioned above should be given by LED manufacturer & Cree/Nichia/
Lumileds/Osrammake LED Source. LEDStreetlight 90W | Each | 9303.0 | 9303.0 | 62.0 | False | None | None | False | None | False | 576786.0 | 0 |
2710094 | 85121 | None | code32 | Supplying and Fixing 40 mm dia class A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clA, bolts, nuts and wiring using suitable capacity wires Using 40mm dia G.I.Pipe | Each | 1551.9 | 1551.9 | 62.0 | False | None | None | False | None | False | 96217.8 | 0 |
2710095 | 85121 | None | code33 | Construction of Granular Sub-Base of required grading as per design mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 For Grading -II Material | Cum | 2688.0 | 2688.0 | 42.75 | False | None | None | False | None | False | 114912.0 | 0 |
2710096 | 85121 | None | code34 | Construction of Granular Sub-Base of required grading as per design mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 For Grading -III Material | Cum | 2636.55 | 2636.55 | 42.75 | False | None | None | False | None | False | 112712.5125 | 0 |