createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1708496394678
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeONE_COVER
evaluationTypeTextOne Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee500.00
emd31750.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose28-02-2024 16:00:00
tenderQueryClose28-02-2024 11:00:00
technicalBidOpenNone
publishedDate21-02-2024 16:25:43
publishedByPostRDPR_EE_DIV_SRS
publishedByUserKPE13012 - SATISH HAYAGRIVACHARYA JAHAGIRDAR
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonEXECUTIVE ENGINEER
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08384226381
mobileNumberNone
tenderSupplierListNone
tenderSchedule
createdTs1708496394723
version5
createdDateNone
modifiedDateNone
tenderNumberRDPR/2023-24/BD/WORK_INDENT4511
titleConstruction of Anganwadi at Madnur in Madnur GP (Category Others)
descriptionConstruction of Anganwadi at Madnur in Madnur GP (Category Others)
categoryWORKS
categoryTextWorks
ecv1269961.58
deptNameRural Development and Panchayat Raj Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location976
locationNameRDPR Division Office Sirsi
provisionalAmount1500000.0
groupOverheadTotalNone
fileNumberSl/SDP/ANGANWADI/08
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17084963950000NoneNoneBuildingsConstruction of Anganwadi at Madnur in Madnur GP (Category Others)1269961.58
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
272816086450NoneCode 1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- WORK COMPLETE 4 MONTHSCum13029.0713029.073.78FalseNoneNoneFalseNoneFalse49249.88460
272816186450NoneCode 2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- WORK COMPLETE 4 MONTHSCum12262.6612262.661.93FalseNoneNoneFalseNoneFalse23666.93380
272816286450NoneCode 3Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- WORK COMPLETE 4 MONTHSCum11113.0311113.031.14FalseNoneNoneFalseNoneFalse12668.85420
272816386450NoneCode 4Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- WORK COMPLETE 4 MONTHSCum12262.6612262.663.95FalseNoneNoneFalseNoneFalse48437.5070
272816486450NoneCode 5Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- WORK COMPLETE 4 MONTHSCum11496.2411496.2413.38FalseNoneNoneFalseNoneFalse153819.69120
272816586450NoneCode 6Steel Fabrication Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire /soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings ---- WORK COMPLETE 4 MONTHSMT100191.84100191.841.8807FalseNoneNoneFalseNoneFalse188430.7934880
272816686450NoneCode 7Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications ---- WORK COMPLETE 4 MONTHSSqm1467.21467.289.76FalseNoneNoneFalseNoneFalse131695.8720
272816786450NoneCode 8Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications ---- WORK COMPLETE 4 MONTHSCum139106.24139106.240.32FalseNoneNoneFalseNoneFalse44513.99680
272816886450NoneCode 9Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance1mm), with wall thickness 2.0 mm (0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm ( 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineer- in-charge. 12.83.1 48x40 mm PVC Extruded section ---- WORK COMPLETE 4 MONTHSm221.76221.7617.1FalseNoneNoneFalseNoneFalse3792.0960
272816986450NoneCode 10Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges -do- with both side prelam ---- WORK COMPLETE 4 MONTHSSqm2649.922649.924.05FalseNoneNoneFalseNoneFalse10732.1760
272817086450NoneCode 11Providing and fixing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) ---- WORK COMPLETE 4 MONTHSSqm7724.647724.645.67FalseNoneNoneFalseNoneFalse43798.70880
272817186450NoneCode 12PProviding & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- WORK COMPLETE 4 MONTHSSqm5625.765625.769.89FalseNoneNoneFalseNoneFalse55638.76640
272817286450NoneCode 13Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser, treads of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints as per direction of Engineer in charge ---- WORK COMPLETE 4 MONTHSSqm1386.561386.5672.54FalseNoneNoneFalseNoneFalse100581.06240
272817386450NoneCode 14Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete ---- WORK COMPLETE 4 MONTHSSqm995.68995.6811.87FalseNoneNoneFalseNoneFalse11818.72160
272817486450NoneCode 15Providing 15 mm cement plaster on the rough side of single or half brick all of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- WORK COMPLETE 4 MONTHSSqm413.0413.0223.42FalseNoneNoneFalseNoneFalse92272.460
272817586450NoneCode 16Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- WORK COMPLETE 4 MONTHSSqm431.2431.2138.07FalseNoneNoneFalseNoneFalse59535.7840
272817686450NoneCode 17Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- WORK COMPLETE 4 MONTHSSqm337.4337.4157.2FalseNoneNoneFalseNoneFalse53039.280
272817786450NoneCode 18Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- WORK COMPLETE 4 MONTHSSqm191.8191.8318.29FalseNoneNoneFalseNoneFalse61048.0220
272817886450NoneCode 19Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge ---- WORK COMPLETE 4 MONTHSSqm124.6124.6148.47FalseNoneNoneFalseNoneFalse18499.3620
272817986450NoneCode 20Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. ---- WORK COMPLETE 4 MONTHSKg204.96204.96226.8FalseNoneNoneFalseNoneFalse46484.9280
272818086450NoneCode 21Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- WORK COMPLETE 4 MONTHSSqm155.68155.6854.36FalseNoneNoneFalseNoneFalse8462.76480
272818186450NoneCode 22Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge ---- WORK COMPLETE 4 MONTHSSqm154.56154.5619.44FalseNoneNoneFalseNoneFalse3004.64640
272818286450NoneCode 23with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 14.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests ---- WORK COMPLETE 4 MONTHSEach5470.085470.081.0FalseNoneNoneFalseNoneFalse5470.080
272818386450NoneCode 24Stainless Steel AISI-304(18/8) Wash basin 530x345 mm with single 15 mm C.P. brass pillar tap ---- WORK COMPLETE 4 MONTHSEach4631.24631.21.0FalseNoneNoneFalseNoneFalse4631.20
272818486450NoneCode 25Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- WORK COMPLETE 4 MONTHScm4.484.48300.0FalseNoneNoneFalseNoneFalse1344.00
272818586450NoneCode 26Supplying heavy gauge PVC conduit pipe 25. dia 2 mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. ---- WORK COMPLETE 4 MONTHSm81.081.045.0FalseNoneNoneFalseNoneFalse3645.00
272818686450NoneCode 27Supplying and fixing PVC/metal conduit Deep junction box 25 mm deep Junction box ---- WORK COMPLETE 4 MONTHSNo56.056.010.0FalseNoneNoneFalseNoneFalse560.00
272818786450NoneCode 28Supplying and fixing 32A security and energy saving DP switch with key tag suitable to operate on 230 V, 50Hz AC supply & completely wired on existing box. ---- WORK COMPLETE 4 MONTHSNo646.0646.01.0FalseNoneNoneFalseNoneFalse646.00
272818886450NoneCode 29Supplying and drawing PVC insulated flexible copper wire of approved make as per IS: 694: 2010 2.4.1 14/0.0040" ---- WORK COMPLETE 4 MONTHSm21.021.050.0FalseNoneNoneFalseNoneFalse1050.00
272818986450NoneCode 30Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:2010 ---- WORK COMPLETE 4 MONTHSm26.026.050.0FalseNoneNoneFalseNoneFalse1300.00
272819086450NoneCode 31Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 3.1.1 6A 2 Way ---- WORK COMPLETE 4 MONTHSEach128.0128.020.0FalseNoneNoneFalseNoneFalse2560.00
272819186450NoneCode 32Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293.3.6.1 6A One Way Switch ---- WORK COMPLETE 4 MONTHSEach102.0102.020.0FalseNoneNoneFalseNoneFalse2040.00
272819286450NoneCode 33Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.10-12 Way ---- WORK COMPLETE 4 MONTHSEach261.0261.010.0FalseNoneNoneFalseNoneFalse2610.00
272819386450NoneCode 34Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.10-12 Module ---- WORK COMPLETE 4 MONTHSEach344.0344.010.0FalseNoneNoneFalseNoneFalse3440.00
272819486450NoneCode 3513.10 Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. ---- WORK COMPLETE 4 MONTHSEach171.0171.02.0FalseNoneNoneFalseNoneFalse342.00
272819586450NoneCode 36Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 6.3.1 48" Sweep (1200 mm) Regular model ---- WORK COMPLETE 4 MONTHSEach2984.02984.02.0FalseNoneNoneFalseNoneFalse5968.00
272819686450NoneCode 37Fixing all types and all capacities of 1'x4' / 2'x2' LED Light fittings indoor on the wall / ceiling / rafters / girders with necessary supporting frame, using 2310.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps ---- WORK COMPLETE 4 MONTHSEach490.0490.03.0FalseNoneNoneFalseNoneFalse1470.00
272819786450NoneCode 38Supplying of recess mounting non integrated type LED down light15-18W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power/COB with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per W, 120degree beam spread, life25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED's are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp Wage, short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. ---- WORK COMPLETE 4 MONTHSEach1671.01671.03.0FalseNoneNoneFalseNoneFalse5013.00
272819886450NoneCode 39Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:2010. 10 mm2 ---- WORK COMPLETE 4 MONTHSEach167.0167.040.0FalseNoneNoneFalseNoneFalse6680.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17084963950000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17084963950000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17084963950000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17084963950000NoneNoneELIGIBILITYDepartment Registration DetailsNone
17084963950000NoneNoneELIGIBILITYTotal value of civl engineering works executed and payments received in the last five years (year-wise)None
17084963950000NoneNoneELIGIBILITYList of existing commitments and ongoing workNone
17084963950000NoneNoneELIGIBILITYList of works for which tenders already submittedNone
17084963950000NoneNoneELIGIBILITYBanker DetailsNone
17084964460000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of KPPP on or before the last date and time of bid submission.None
17084964600000NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of KPPP portal due to internet connectivity issues and technical glitches at bidders endNone
17084964680000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejectionNone
17084964750000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidderNone
17084964810000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17084964920000NoneNoneELIGIBILITYThe bid is to be submitted through GOK KPPP platform www.kppp.karnataka.gov.in only.None
17084965020000NoneNoneELIGIBILITYTenderers who have not registered in the GOK KPPP portal should be registered through web site www.kppp.karnataka.gov.inNone
17084965120000NoneNoneELIGIBILITYThe Tenderer should obtain tender documents through KPPP web site www.kppp.karnataka.gov.in . in at free of cost. Additional conditions and informations also can be obtained through the above mentioned websiteNone
17084965180000NoneNoneELIGIBILITYBidders / Contractors submit the bid on the website itself (for help on KPPP / e-payment, please contact helpdesk No. 08025501216 and 080 25501227 from Monday to Saturday during 9.00 AM to 9.00 PM.)None
17084965270000NoneNoneELIGIBILITYAny damage during the progress of work, the damage cost should be beard by the contractorNone
17084965360000NoneNoneELIGIBILITYTender application cost will not be refundable or exchangeable in case of cancellation of tenderNone
17084965470000NoneNoneELIGIBILITYAll materials should be in good quality as per specification, quality certificate for the same should be obtained from the concerned authority at their own costNone
17084965570000NoneNoneELIGIBILITYThe work should be carried out in accordance with the standard specifications specified by the department. Maintenance period from the contractor for the above works is 1 year from the date of completion of workNone
17084965660000NoneNoneELIGIBILITYCorrigendums / modifications / correction, if any, will be published in the website onlyNone
17084965720000NoneNoneELIGIBILITYMore details should be collected from the office at working hoursNone
17084965910000NoneNoneELIGIBILITYThe Executive Engineer rights accept and reject the tender without intimation or informationNone
17084966200000NoneNoneELIGIBILITYThe Executive Engineer PRE SIRSI Division SIRSI invites tenders from eligible tenderers who have been registered in KPWD with kppp portal for the construction of worksNone
17084966350000NoneNoneELIGIBILITYContractor should made an agreement within 20 days of tender acceptance date and work should be carried out immediately after Signing agreement. If not tender will be cancelled at the contractors own risk and costNone
17084966690000NoneNoneELIGIBILITYGST Shall be paid to the tendered amount separatelyNone
17084966750000NoneNoneELIGIBILITYThe Contractor should scan the KPWD Registration Copy.None
17084966820000NoneNoneELIGIBILITYThe Contractor should scan the PAN Card and GST No.None
17084966910000NoneNoneELIGIBILITYContractors Postal Address and Mobile No.None
17084967200000NoneNoneELIGIBILITYBidder can access tender documents on the website, fill them and submit the completed tender document into electronic tender on the website https://www.kppp.karnataka.gov.in/None
17084967300000NoneNoneELIGIBILITYEMD shall be paid in the form of e-payment through KPPP portal on or before as per the last date and time mentioned in the KPPP portal.None
17084967400000NoneNoneELIGIBILITYBidder can access tender documents on the website, fill them and submit the completed tender document into electronic tender on the website https://www.kppp.karnataka.gov.in/ after submitting the EMD and tender processing fee in the form of e-payment. EMD will be refunded only after acceptance of successful bidder.None
17084967520000NoneNoneELIGIBILITYIf the rates quoted by the Contractor is lesser than the amount put to tender the difference cost (Additional Security Deposit) should be paid by the contractor through FDR in the favor of Executive Engineer at the time of AgreementNone
17084967620000NoneNoneELIGIBILITYContractor should obey with the above conditions in addition to the KW-1None
17084967720000NoneNoneELIGIBILITYTurn over Certificate should be enclosed for the last previous 5 years from charted accountant in singal page and achieved in at least two financial year a minimum financial turnover is equal or above of Rs: 12.70 lakhsNone
17084968350000NoneNoneELIGIBILITYTenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity should be not less than Rs: 12.70 lakhsNone
preQualCriterionListNone
technicalCriterionListNone
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
The Executive Engineer, P.R.E. SIRSI Division, SIRSI invites tenders from eligible tenderers, who have been registered in KPWD and with kppp portal for the construction of worksTrueTechnical Bid
Financial Turnover Certificate Should be Enclosed For the last previous 5 years From Charted Accountant in a single pageTrueTechnical Bid
VAT/ GST CertificateTrueTechnical Bid
KW 1 format 1.3 A and 1.3 B compulsary Submitted with detailsTrueTechnical Bid
The Contractor should scan the KPWD Registration CopyTrueTechnical Bid
The Contractor should scan the PAN CardTrueTechnical Bid
Contractors Postal Address and Mobile No.TrueTechnical Bid
EMD shall be paid in the form of e-payment through kppp portal on or before as per the last date and time mentioned in the kppp portal.TrueTechnical Bid
Turn over Certificate should be enclosed for the last previous 5 years from charted accountent in singal page and achieved in at least two financial year a minimum financial turnover is equal or above of Rs. 12.70 lakhsTrueTechnical Bid
Tenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity should be not less than Rs. 12.70 lakhsTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone