| 1708508929000 | 0 | None | None | Buildings | Construction of School Building in Higher Primary School in Bogadhi of Mysuru Taluk | 2527716.2 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 2736852 | 86774 | None | code01 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m. | Cum | 105.06 | 105.06 | 34.235 | False | None | None | False | None | False | 3596.7291 | 0 | | 2736853 | 86774 | None | code02 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depth. (SR-2023-24, Volume-I, Chapter-01,Page No.08, Iteam No.1.15.1). | Cum | 373.89 | 373.89 | 40.64 | False | None | None | False | None | False | 15194.8896 | 0 | | 2736854 | 86774 | None | code03 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications..Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates. | Cum | 6074.94 | 6074.94 | 30.72 | False | None | None | False | None | False | 186622.1568 | 0 | | 2736855 | 86774 | None | code04 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with. Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5779.33 | 5779.33 | 15.73 | False | None | None | False | None | False | 90908.8609 | 0 | | 2736856 | 86774 | None | code05 | Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6391.15 | 6391.15 | 10.37 | False | None | None | False | None | False | 66276.2255 | 0 | | 2736857 | 86774 | None | code06 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (SR-2023-24, Volume-I, Chapter-01,Page No.07, Iteam No.1.9). | Cum | 273.98 | 273.98 | 54.75 | False | None | None | False | None | False | 15000.405 | 0 | | 2736858 | 86774 | None | code07 | Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge.(P.No.44 /I.No. 8.19.1 of CSR 2021-22, Volume-II, Chapter-8) | Sqm | 204.97 | 204.97 | 15.74 | False | None | None | False | None | False | 3226.2278 | 0 | | 2736859 | 86774 | None | code08 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. .M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (SR-2023-24, Volume-I, Chapter-02,Page No.15, Item No.2.2.1) | Cum | 6664.21 | 6664.21 | 11.77 | False | None | None | False | None | False | 78437.7517 | 0 | | 2736860 | 86774 | None | code09 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. .M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (SR-2023-24, Volume-I, Chapter-02,Page No.15, Item No.2.2.1) Plinth Beam | Cum | 9619.11 | 9619.11 | 3.79 | False | None | None | False | None | False | 36456.4269 | 0 | | 2736861 | 86774 | None | code10 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. .M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (SR-2023-24, Volume-I, Chapter-02,Page No.15, Item No.2.2.1) Flagging concrete | Cum | 6287.0 | 6287.0 | 3.6 | False | None | None | False | None | False | 22633.2 | 0 | | 2736862 | 86774 | None | code11 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges up to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (SR-2023-24, Volume-I, Chapter-02,Page No.16, Item No.2.5.2) | Cum | 11838.39 | 11838.39 | 6.78 | False | None | None | False | None | False | 80264.2842 | 0 | | 2736863 | 86774 | None | code12 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labor, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (SR-2023-24, Volume-I, Chapter-02,Page No.16, Item No.2.5.2) Chajja (w) | Cum | 10127.64 | 10127.64 | 0.43 | False | None | None | False | None | False | 4354.8852 | 0 | | 2736864 | 86774 | None | code13 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (SR-2023-24, Volume-I, Chapter-02,Page No.16, I team No.2.5.2)Lintel Beam | Cum | 11154.09 | 11154.09 | 9.3 | False | None | None | False | None | False | 103733.037 | 0 | | 2736865 | 86774 | None | code14 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (SR-2023-24, Volume-I, Chapter-02,Page No.16, Item No.2.5.2) Roof | Cum | 10469.79 | 10469.79 | 20.97 | False | None | None | False | None | False | 219551.4963 | 0 | | 2736866 | 86774 | None | code15 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (SR-2023-24, Volume-I, Chapter-02,Page No.16, Item No.2.5.2) Head room | Cum | 11956.77 | 11956.77 | 0.6 | False | None | None | False | None | False | 7174.062 | 0 | | 2736867 | 86774 | None | code16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges up to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (SR-2023-24, Volume-I, Chapter-02,Page No.16, Item No.2.5.2) Chajja (w) | Cum | 10228.91 | 10228.91 | 0.22 | False | None | None | False | None | False | 2250.3602 | 0 | | 2736868 | 86774 | None | code17 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (SR-2023-24, Volume-I, Chapter-02,Page No.16, Item No.2.5.2) Lintel Beam | Cum | 11265.63 | 11265.63 | 1.86 | False | None | None | False | None | False | 20954.0718 | 0 | | 2736869 | 86774 | None | code18 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (SR-2023-24, Volume-I, Chapter-02,Page No.16, Item No.2.5.2) Roof | Cum | 10574.48 | 10574.48 | 2.85 | False | None | None | False | None | False | 30137.268 | 0 | | 2736870 | 86774 | None | code19 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification Buildings. (SR-2023-24, Volume-I, Chapter-02,Page No.18, Item No.2.11.a) | MT | 92140.71 | 92140.71 | 4.3757 | False | None | None | False | None | False | 403180.104747 | 0 | | 2736871 | 86774 | None | code20 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. Buildings. (SR-2023-24, Volume-I, Chapter-02,Page No.18, Item No.2.11.a) Head room | MT | 93062.11 | 93062.11 | 0.5054 | False | None | None | False | None | False | 47033.590394 | 0 | | 2736872 | 86774 | None | code21 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer in charge of work.(SR-2023-24, Volume II, Chapter-06, Page No.13, Item No. 6.2) | Cum | 8217.34 | 8217.34 | 28.72 | False | None | None | False | None | False | 236002.0048 | 0 | | 2736873 | 86774 | None | code22 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer in charge of work.(SR-2023-24, Volume II, Chapter-06, Page No.13, Item No. 6.2)Head Room | Cum | 8299.51 | 8299.51 | 11.31 | False | None | None | False | None | False | 93867.4581 | 0 | | 2736874 | 86774 | None | code23 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labor, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (SR-2023-24, Volume II, Chapter-11, Page No.82,Item No. 11.16.2) | Kgs | 151.41 | 151.41 | 71.94 | False | None | None | False | None | False | 10892.4354 | 0 | | 2736875 | 86774 | None | code24 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labor, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (SR-2023-24, Volume II, Chapter-11, Page No.82,Item No. 11.16.2) Head room | Kgs | 152.92 | 152.92 | 35.97 | False | None | None | False | None | False | 5500.5324 | 0 | | 2736876 | 86774 | None | code25 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labor, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. (SR-2023-24, Volume II, Chapter-11, Page No.77.0,Item No. 11.5.1) | Sqm | 4612.34 | 4612.34 | 5.04 | False | None | None | False | None | False | 23246.1936 | 0 | | 2736877 | 86774 | None | code26 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labor, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. (SR-2023-24, Volume II, Chapter-11, Page No.77.0,Item No. 11.5.1) Head room | Sqm | 4658.46 | 4658.46 | 2.52 | False | None | None | False | None | False | 11739.3192 | 0 | | 2736878 | 86774 | None | code27 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. (SR-2023-24, Volume II, Chapter-11, Page No.86,Item No. 11.34A) | Kgs | 173.04 | 173.04 | 272.15 | False | None | None | False | None | False | 47092.836 | 0 | | 2736879 | 86774 | None | code28 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. (SR-2023-24, Volume II, Chapter-11, Page No.86,Item No. 11.34A) Head room | Kgs | 174.77 | 174.77 | 37.8 | False | None | None | False | None | False | 6606.306 | 0 | | 2736880 | 86774 | None | code29 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labor, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (SR-2023-24, Volume II, Chapter-11, Page No.79.0,Item No. 11.11.1) | Kgs | 152.44 | 152.44 | 246.24 | False | None | None | False | None | False | 37536.8256 | 0 | | 2736881 | 86774 | None | code30 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitered and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (SR-2023-24, Volume II, Chapter-11, Page No.79.0,Item No. 11.11.1) Head Room | Kgs | 153.96 | 153.96 | 34.2 | False | None | None | False | None | False | 5265.432 | 0 | | 2736882 | 86774 | None | code31 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labor, curing complete as per specifications and as per directions of Engineer-in-charge.(SR-2023-24, Volume II, Chapter-08, Page No.41.0, Item No. 8.4.2) | Sqm | 248.23 | 248.23 | 107.65 | False | None | None | False | None | False | 26721.9595 | 0 | | 2736883 | 86774 | None | code32 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labor, curing complete as per specifications and as per directions of Engineer-in-charge.(SR-2023-24, Volume II, Chapter-08, Page No.41.0, Item No. 8.4.2) Head room | Sqm | 250.71 | 250.71 | 16.5 | False | None | None | False | None | False | 4136.715 | 0 | | 2736884 | 86774 | None | code33 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(SR-2023-24, Volume II, Chapter-08, Page No.41.0, Item No. 8.2.2) | Sqm | 287.37 | 287.37 | 167.94 | False | None | None | False | None | False | 48260.9178 | 0 | | 2736885 | 86774 | None | code34 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(SR-2023-24, Volume II, Chapter-08, Page No.41.0, Item No. 8.2.2) Head room | Sqm | 290.24 | 290.24 | 52.77 | False | None | None | False | None | False | 15315.9648 | 0 | | 2736886 | 86774 | None | code35 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labor, curing complete as per specifications and as per direct- tons of Engineer-in-charge.(SR-2023-24, Volume II, Chapter-08, Page No.41.0, Item No. 8.3.2) | Sqm | 342.99 | 342.99 | 179.76 | False | None | None | False | None | False | 61655.8824 | 0 | | 2736887 | 86774 | None | code36 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge.(SR-2023-24, Volume II, Chapter-08, Page No.41.0, Item No. 8.3.2) Head Room | Sqm | 346.41 | 346.41 | 84.91 | False | None | None | False | None | False | 29413.6731 | 0 | | 2736888 | 86774 | None | code37 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rub- bing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :** Flamed finish granite stone slab Black, Cat Eye, River Pink or equivalent. (SR-2023-24, Volume II, Chapter-09, Page No.63.0,Item No. 9.23) | Sqm | 1179.35 | 1179.35 | 75.16 | False | None | None | False | None | False | 88639.946 | 0 | | 2736889 | 86774 | None | code38 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (SR-2023-24, Volume II, Chapter-11, Page No.84,Item No. 11.26.1) | Kgs | 142.14 | 142.14 | 247.5 | False | None | None | False | None | False | 35179.65 | 0 | | 2736890 | 86774 | None | code39 | Providing and laying Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). .Light shade pigment using white cement. (SR-2023-24, Volume II, Chapter-09, Page No.59.0,Item No. 9.6.2) | Sqm | 1307.07 | 1307.07 | 56.08 | False | None | None | False | None | False | 73300.4856 | 0 | | 2736891 | 86774 | None | code40 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and in- clouding water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (SR-2023-24, Volume II, Chapter-08, Page No.45.0, Item No. 8.25) | Sqm | 141.11 | 141.11 | 275.59 | False | None | None | False | None | False | 38888.5049 | 0 | | 2736892 | 86774 | None | code41 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and in- cluding water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labor complete as per specifications and as per directions of Engineer-in-charge. (SR-2023-24, Volume II, Chapter-08, Page No.45.0, Item No. 8.25) Head room | Sqm | 142.52 | 142.52 | 69.27 | False | None | None | False | None | False | 9872.3604 | 0 | | 2736893 | 86774 | None | code42 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labor complete as per specifications and as per directions of Engineer-in-charge. (SR-2023-24, Volume II, Chapter-08, Page No.47.0, Item No. 8.33.3) | Sqm | 143.17 | 143.17 | 31.1 | False | None | None | False | None | False | 4452.587 | 0 | | 2736894 | 86774 | None | code43 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (SR-2023-24, Volume II, Chapter-08, Page No.47.0, Item No. 8.33.3) Head Room | Sqm | 144.6 | 144.6 | 4.32 | False | None | None | False | None | False | 624.672 | 0 | | 2736895 | 86774 | None | code44 | Polyurethane based Single Component for New Surface.Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU wa- terproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the wa- terproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. (SR-2023-24, Volume-II, Chapter-15,Page No.149, Item No.15.1) | Sqm | 841.51 | 841.51 | 93.99 | False | None | None | False | None | False | 79093.5249 | 0 | | 2736896 | 86774 | None | code45 | Polyurethane based Single Component for New Surface.Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU wa- terproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the wa- terproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. (SR-2023-24, Volume-II, Chapter-15,Page No.149, Item No.15.1) Head room | Sqm | 849.92 | 849.92 | 16.5 | False | None | None | False | None | False | 14023.68 | 0 | | 2736897 | 86774 | None | code46 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS 5382, leaving 10 mm gap for thermal expansion, Single socketed pipes 100 mm diameter. | Mtr | 299.73 | 299.73 | 17.4 | False | None | None | False | None | False | 5215.302 | 0 | | 2736898 | 86774 | None | code47 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS 5382, leaving 10 mm gap for thermal expansion, Single socketed pipes 100 mm diameter. Head room Rainwater pipe | Mtr | 302.72 | 302.72 | 6.5 | False | None | None | False | None | False | 1967.68 | 0 | | 2736899 | 86774 | None | code48 | Providing wall black boards in 12mm thick with CM 1:3 and applied with primer & two coats of acrylic emulsion black paint including finishing etc.,complete. (SR-2023-24, Volume II, Chapter-08, Page No.55.0,Item No. 8.84) | Sqm | 489.25 | 489.25 | 8.4 | False | None | None | False | None | False | 4109.7 | 0 | | 2736900 | 86774 | None | code49 | Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja,facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications.(SR-2023-24, Volume II, Chapter-08, Page No.44.0, Item No. 8.16a) | Sqm | 1275.14 | 1275.14 | 22.22 | False | None | None | False | None | False | 28333.6108 | 0 | | 2736901 | 86774 | None | code50 | Supplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25 mm dia 2 mm thick (PWD SR 2022-23 Part-I Pg No. 1, Item No. 1.1.2 ) | Mtr | 80.0 | 80.0 | 130.0 | False | None | None | False | None | False | 10400.0 | 0 | | 2736902 | 86774 | None | code51 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3m from tapping point to out let via switch(PWD SR 2022-23 Part-I Pg No. 2, Item No. 2.1.1 ) | No | 276.0 | 276.0 | 11.0 | False | None | None | False | None | False | 3036.0 | 0 | | 2736903 | 86774 | None | code52 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3m from tapping point to out let via switch(PWD SR 2022-23 Part-I Pg No. 2, Item No. 2.1.1 )(b) Medium point above 3m upto 6m from tapping point to out let via switch | No | 386.0 | 386.0 | 3.0 | False | None | None | False | None | False | 1158.0 | 0 | | 2736904 | 86774 | None | code53 | Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 6A 2 Way (PWD SR 2022-23 Part-I Pg No. 5, Item No. 3.1 ) | No | 121.0 | 121.0 | 14.0 | False | None | None | False | None | False | 1694.0 | 0 | | 2736905 | 86774 | None | code54 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2 (PWD SR 2022-23 Part-I Pg No. 3, Item No. 2.3.3) | No | 40.0 | 40.0 | 280.0 | False | None | None | False | None | False | 11200.0 | 0 | | 2736906 | 86774 | None | code55 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Three Way socket (PWD SR 2022-23 Part-I Pg No. 5, Item No. 3.6.3) | No | 162.0 | 162.0 | 16.0 | False | None | None | False | None | False | 2592.0 | 0 | | 2736907 | 86774 | None | code56 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP (PWD SR 2022-23 Part-I Pg No. 13, Item No.5.17.1) | No | 523.0 | 523.0 | 2.0 | False | None | None | False | None | False | 1046.0 | 0 | | 2736908 | 86774 | None | code57 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 56" Sweep (1400 mm) Regular model (PWD SR 2022-23 Part-I Pg No. 22 Item No.6.3.2) | No | 2170.0 | 2170.0 | 4.0 | False | None | None | False | None | False | 8680.0 | 0 | | 2736909 | 86774 | None | code58 | Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70 lumen maintenance with CRI 80. Power Input: 220-240V & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting W (PWD CSR 2022-23, I.No.11.3.1) | No | 496.0 | 496.0 | 8.0 | False | None | None | False | None | False | 3968.0 | 0 |
|