| 2648976 | 82622 | None | code01 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth PWD SR 2023-24 Vol-1 Item No. 1.12 Page No. 08 PWD SR 2023-24 Vol-1 Item No. 1.12 Page No. 08 | Cum | 99.75 | 99.75 | 29.1 | False | 0.0 | 0.0 | False | None | False | 2902.725 | 0 |
| 2648977 | 82622 | None | code02 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m PWD SR 2023-24 Vol-1 Item No. 1.14 Page No. 08 PWD SR 2023-24 Vol-1 Item No. 1.14 Page No. 08 | Cum | 107.1 | 107.1 | 125.66 | False | None | None | False | None | False | 13458.186 | 0 |
| 2648978 | 82622 | None | code03 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates PWD SR 2023-24 Vol-1 Item No. 2.1.3 Page No. 15 PWD SR 2023-24 Vol-1 Item No. 2.1.3 Page No. 15 | Cum | 6288.45 | 6288.45 | 10.0215 | False | None | None | False | None | False | 63019.701675 | 0 |
| 2648979 | 82622 | None | code04 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD SR 2023-24 Vol-1 Item No. 2.2.3 Page No. 15 PWD SR 2023-24 Vol-1 Item No. 2.2.3 Page No. 15 | Cum | 6652.8 | 6652.8 | 16.15 | False | None | None | False | None | False | 107442.72 | 0 |
| 2648980 | 82622 | None | code05 | Add 8% for Form Work, Addendum-I | Cum | 532.22 | 532.22 | 16.15 | False | None | None | False | None | False | 8595.353 | 0 |
| 2648981 | 82622 | None | code06 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD SR 2023-24 Vol-1 Item No. 2.2.3 Page No. 15 PWD SR 2023-24 Vol-1 Item No. 2.2.3 Page No. 15 | Cum | 6652.8 | 6652.8 | 9.1633 | False | None | None | False | None | False | 60961.60224 | 0 |
| 2648982 | 82622 | None | code07 | Add 70% for Form Work, Addendum-I | Cum | 4656.96 | 4656.96 | 9.1633 | False | None | None | False | None | False | 42673.121568 | 0 |
| 2648983 | 82622 | None | code08 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD SR 2023-24 Vol-1 Item No. 2.4.3 Page No. 16 PWD SR 2023-24 Vol-1 Item No. 2.4.3 Page No. 16 | Cum | 6652.8 | 6652.8 | 6.9117 | False | None | None | False | None | False | 45982.15776 | 0 |
| 2648984 | 82622 | None | code09 | Add 50% for Form Work, Addendum-I | Cum | 3326.4 | 3326.4 | 6.9117 | False | None | None | False | None | False | 22991.07888 | 0 |
| 2648985 | 82622 | None | code10 | Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) PWD SR 2023-24 Vol-II Item No. 5.2 Page No. 09 PWD SR 2023-24 Vol-II Item No. 5.2 Page No. 09 | Cum | 6948.9 | 6948.9 | 24.5565 | False | None | None | False | None | False | 170640.66285 | 0 |
| 2648986 | 82622 | None | code11 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) PWD SR 2023-24 Vol-II Item No. 5.4 Page No. 09 PWD SR 2023-24 Vol-II Item No. 5.4 Page No. 09 | Cum | 6708.45 | 6708.45 | 17.0748 | False | None | None | False | None | False | 114545.44206 | 0 |
| 2648987 | 82622 | None | code12 | Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge. PWD SR 2023-24 V -II Item No. 8.19.1 Page No. 44 PWD SR 2023-24 Vol-II Item No. 8.19.1 Page No. 44 | Sqm | 267.75 | 267.75 | 31.326 | False | None | None | False | None | False | 8387.5365 | 0 |
| 2648988 | 82622 | None | code13 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m PWD SR 2023-24 V -I Item No. 1.9 Page No. 07 PWD SR 2023-24 Vol-I Item No. 1.9 Page No. 07 | Cum | 279.3 | 279.3 | 105.7175 | False | None | None | False | None | False | 29526.89775 | 0 |
| 2648989 | 82622 | None | code14 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. PWD SR 2023-24 V -II Item No. 6.7 Page No. 13 PWD SR 2023-24 Vol-II Item No. 6.7 Page No. 13 | Cum | 8621.55 | 8621.55 | 40.7183 | False | None | None | False | None | False | 351054.859365 | 0 |
| 2648990 | 82622 | None | code15 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD SR 2023-24 V -I Item No. 2.5.2 Page No. 16 PWD SR 2023-24 Vol-I Item No. 2.5.2 Page No. 16 | Cum | 7185.15 | 7185.15 | 2.0824 | False | None | None | False | None | False | 14962.35636 | 0 |
| 2648991 | 82622 | None | code16 | Add 60% for Form Work, Addendum-I | Cum | 4311.09 | 4311.09 | 2.0824 | False | None | None | False | None | False | 8977.413816 | 0 |
| 2648992 | 82622 | None | code17 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD SR 2023-24 V -I Item No. 2.5.2 Page No. 16 PWD SR 2023-24 Vol-I Item No. 2.5.2 Page No. 16 | Cum | 7185.15 | 7185.15 | 6.8207 | False | None | None | False | None | False | 49007.752605 | 0 |
| 2648993 | 82622 | None | code18 | Add 60% for Form Work, Addendum-I | Cum | 4311.09 | 4311.09 | 6.8207 | False | None | None | False | None | False | 29404.651563 | 0 |
| 2648994 | 82622 | None | code19 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD SR 2023-24 V -I Item No. 2.5.2 Page No. 16 PWD SR 2023-24 Vol-I Item No. 2.5.2 Page No. 16 | Cum | 7185.15 | 7185.15 | 13.824 | False | None | None | False | None | False | 99327.5136 | 0 |
| 2648995 | 82622 | None | code20 | Add 50% for Form Work, Addendum-I | Cum | 3592.58 | 3592.58 | 13.824 | False | None | None | False | None | False | 49663.82592 | 0 |
| 2648996 | 82622 | None | code21 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. PWD SR 2023-24 Vol -II Item No. 8.10 Page No. 43 PWD SR 2023-24 Vol -II Item No. 8.10 Page No. 43 | Cum | 221.55 | 221.55 | 92.16 | False | None | None | False | None | False | 20418.048 | 0 |
| 2648997 | 82622 | None | code22 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD SR 2023-24 V -I Item No. 2.5.2 Page No. 16 PWD SR 2023-24 Vol-I Item No. 2.5.2 Page No. 16 | Cum | 7185.15 | 7185.15 | 1.9815 | False | None | None | False | None | False | 14237.374725 | 0 |
| 2648998 | 82622 | None | code23 | Add 50% for Form Work, Addendum-I | Cum | 3592.58 | 3592.58 | 1.9815 | False | None | None | False | None | False | 7118.69727 | 0 |
| 2648999 | 82622 | None | code24 | Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. PWD SR 2023-24 Vol -II Item No. 12.11 Page No. 99 PWD SR 2023-24 Vol -II Item No. 12.11 Page No. 99 | Cum | 144977.7 | 144977.7 | 0.2663 | False | None | None | False | None | False | 38607.56151 | 0 |
| 2649000 | 82622 | None | code25 | Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures ) PWD SR 2023-24 Vol -II Item No. 12.15 Page No. 100 PWD SR 2023-24 Vol -II Item No. 12.15 Page No. 100 | Sqm | 7816.2 | 7816.2 | 8.19 | False | None | None | False | None | False | 64014.678 | 0 |
| 2649001 | 82622 | None | code26 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @0.75 L/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. PWD SR 2023-24 Vol -II Item No. 8.33.2 B Page No. 46 PWD SR 2023-24 Vol -II Item No. 8.33.2 B Page No. 46 | Sqm | 144.9 | 144.9 | 21.294 | False | None | None | False | None | False | 3085.5006 | 0 |
| 2649002 | 82622 | None | code27 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. PWD SR 2023-24 Vol -II Item No. 11.34B Page No. 86 PWD SR 2023-24 Vol -II Item No. 11.34B Page No. 86 | Kg | 192.15 | 192.15 | 39.69 | False | None | None | False | None | False | 7626.4335 | 0 |
| 2649003 | 82622 | None | code28 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. PWD SR 2023-24 V0l -II Item No. 8.8 Page No. 42 PWD SR 2023-24 V0l -II Item No. 8.8 Page No. 42 | Sqm | 389.55 | 389.55 | 212.27 | False | None | None | False | None | False | 82689.7785 | 0 |
| 2649004 | 82622 | None | code29 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. PWD SR 2023-24 Vol -II Item No. 8.1.2 Page No. 41 PWD SR 2023-24 Vol -II Item No. 8.1.2 Page No. 41 | Sqm | 253.05 | 253.05 | 214.048 | False | None | None | False | None | False | 54164.8464 | 0 |
| 2649005 | 82622 | None | code30 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. PWD SR 2023-24 Vol -II Item No. 8.1.2 Page No. 41 PWD SR 2023-24 Vol -II Item No. 8.1.2 Page No. 41 | Sqm | 253.05 | 253.05 | 13.651 | False | None | None | False | None | False | 3454.38555 | 0 |
| 2649006 | 82622 | None | code31 | providing and laying Polished Granite stone flooring in required design
and patterns, in linear as well as curvilinear portions of the building all
complete as per the architectural drawings with 18 mm thick stone slab
over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4
coarse sand) laid and jointed with cement slurry and pointing with white
cement slurry admixed with pigment of matching shade including rubbing,
curing and polishing etc. all complete as specified and as directed by the
Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. PWD SR 2023-24 V -II Item No. 9.24 Page No. 63 PWD SR 2023-24 V -II Item No. 9.24 Page No. 63 | Sqm | 2994.6 | 2994.6 | 94.395 | False | None | None | False | None | False | 282675.267 | 0 |
| 2649007 | 82622 | None | code32 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per pecifications and as per directions of Engineer in charge. PWD SR 2023-24 V -II Item No. 8.51 Page No. 50 PWD SR 2023-24 V -II Item No. 8.51 Page No. 50 | Sqm | 105.0 | 105.0 | 319.859 | False | None | None | False | None | False | 33585.195 | 0 |
| 2649008 | 82622 | None | code33 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. PWD SR 2023-24 V -II Item No. 8.39 Page No. 48 PWD SR 2023-24 V -II Item No. 8.39 Page No. 48 | Sqm | 133.35 | 133.35 | 319.859 | False | None | None | False | None | False | 42653.19765 | 0 |
| 2649009 | 82622 | None | code34 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to move all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. PWD SR 2021-22 V -II Item No.8.31 Page No. 46 PWD SR 2023-24 V -II Item No.8.31 Page No. 46 | Sqm | 186.9 | 186.9 | 212.27 | False | None | None | False | None | False | 39673.263 | 0 |
| 2649010 | 82622 | None | code35 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. PWD SR 2023-24 V -II Item No.8.33.3 Page No. 47 PWD SR 2023-24 V -II Item No.8.33.3 Page No. 47 | Sqm | 145.95 | 145.95 | 1.89 | False | None | None | False | None | False | 275.8455 | 0 |
| 2649011 | 82622 | None | code36 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. PWD SR 2023-24 V -I Item No. 2.11.a Page No. 18 PWD SR 2023-24 V -I Item No. 2.11.a Page No. 18 | Tonne | 93929.85 | 93929.85 | 5.1196 | False | None | None | False | None | False | 480883.26006 | 0 |
| 2649012 | 82622 | None | code37 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. PWD SR 2023-24 V -II Item No.11.28 Page No. 85 PWD SR 2023-24 V -II Item No.11.28 Page No. 85 | Kg | 593.25 | 593.25 | 378.0 | False | None | None | False | None | False | 224248.5 | 0 |
| 2649013 | 82622 | None | code38 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD SR 2023-24 Vol-1 Item No. 2.2.3 Page No. 15 PWD SR 2023-24 Vol-1 Item No. 2.2.3 Page No. 15 | Cum | 6652.8 | 6652.8 | 3.519 | False | None | None | False | None | False | 23411.2032 | 0 |
| 2649014 | 82622 | None | code39 | Add 70 % For Formwork, Addendum-I | Cum | 4656.96 | 4656.96 | 3.519 | False | None | None | False | None | False | 16387.84224 | 0 |
| 2649015 | 82622 | None | code40 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. PWD SR 2023-24 V -II Item No. 6.7 Page No. 13 PWD SR 2023-24 Vol-II Item No. 6.7 Page No. 13 | Cum | 8621.55 | 8621.55 | 56.0333 | False | None | None | False | None | False | 483093.897615 | 0 |
| 2649016 | 82622 | None | code41 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD SR 2023-24 V -I Item No. 2.5.2 Page No. 16 PWD SR 2023-24 Vol-I Item No. 2.5.2 Page No. 16 | Cum | 7185.15 | 7185.15 | 0.1992 | False | None | None | False | None | False | 1431.28188 | 0 |
| 2649017 | 82622 | None | code42 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD SR 2023-24 V -I Item No. 2.5.2 Page No. 16 PWD SR 2023-24 Vol-I Item No. 2.5.2 Page No. 16 | Cum | 7185.15 | 7185.15 | 2.0824 | False | None | None | False | None | False | 14962.35636 | 0 |
| 2649018 | 82622 | None | code43 | Add 60 % For Formwork, Addendum-I | Cum | 4311.09 | 4311.09 | 2.0824 | False | None | None | False | None | False | 8977.413816 | 0 |
| 2649019 | 82622 | None | code44 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD SR 2023-24 V -I Item No. 2.5.2 Page No. 16 PWD SR 2023-24 Vol-I Item No. 2.5.2 Page No. 16 | Cum | 7185.15 | 7185.15 | 0.567 | False | None | None | False | None | False | 4073.98005 | 0 |
| 2649020 | 82622 | None | code45 | Add 45 % For Formwork, Addendum-I | Cum | 3233.32 | 3233.32 | 0.567 | False | None | None | False | None | False | 1833.29244 | 0 |
| 2649021 | 82622 | None | code46 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD SR 2023-24 V -I Item No. 2.5.2 Page No. 16 PWD SR 2023-24 Vol-I Item No. 2.5.2 Page No. 16 | Cum | 7185.15 | 7185.15 | 6.8207 | False | None | None | False | None | False | 49007.752605 | 0 |
| 2649022 | 82622 | None | code47 | Add 60 % For Formwork, Addendum-I | Cum | 4311.09 | 4311.09 | 6.8207 | False | None | None | False | None | False | 29404.651563 | 0 |
| 2649023 | 82622 | None | code48 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD SR 2023-24 V -I Item No. 2.5.2 Page No. 16 PWD SR 2023-24 Vol-I Item No. 2.5.2 Page No. 16 | Cum | 7185.15 | 7185.15 | 14.3865 | False | None | None | False | None | False | 103369.160475 | 0 |
| 2649024 | 82622 | None | code49 | Add 50 % For Formwork, Addendum-I | Cum | 3592.58 | 3592.58 | 14.3865 | False | None | None | False | None | False | 51684.65217 | 0 |
| 2649025 | 82622 | None | code50 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. PWD SR 2023-24 Vol -II Item No. 8.10 Page No. 43 PWD SR 2023-24 Vol -II Item No. 8.10 Page No. 43 | Sqm | 221.55 | 221.55 | 95.91 | False | None | None | False | None | False | 21248.8605 | 0 |
| 2649026 | 82622 | None | code51 | Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. PWD SR 2023-24 Vol -II Item No. 12.11 Page No. 99 PWD SR 2023-24 Vol -II Item No. 12.11 Page No. 99 | Cum | 144977.7 | 144977.7 | 0.3244 | False | None | None | False | None | False | 47030.76588 | 0 |
| 2649027 | 82622 | None | code52 | Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures ) PWD SR 2023-24 Vol -II Item No. 12.15 Page No. 100 PWD SR 2023-24 Vol -II Item No. 12.15 Page No. 100 | Sqm | 7816.2 | 7816.2 | 8.82 | False | None | None | False | None | False | 68938.884 | 0 |
| 2649028 | 82622 | None | code53 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @0.75 L/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. PWD SR 2023-24 Vol -II Item No. 8.33.2 B Page No. 46 PWD SR 2023-24 Vol -II Item No. 8.33.2 B Page No. 46 | Sqm | 144.9 | 144.9 | 22.932 | False | None | None | False | None | False | 3322.8468 | 0 |
| 2649029 | 82622 | None | code54 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. PWD SR 2023-24 Vol -II Item No. 11.34B Page No. 86 PWD SR 2023-24 Vol -II Item No. 11.34B Page No. 86 | Sqm | 192.15 | 192.15 | 309.015 | False | None | None | False | None | False | 59377.23225 | 0 |
| 2649030 | 82622 | None | code55 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made). PWD SR 2023-24 Vol -II Item No. 12.90 B Page No. 110 PWD SR 2023-24 Vol -II Item No. 12.90 B Page No. 110 | Sqm | 7070.7 | 7070.7 | 14.175 | False | None | None | False | None | False | 100227.1725 | 0 |
| 2649031 | 82622 | None | code56 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. PWD SR 2023-24 V0l -II Item No. 8.8 Page No. 42 PWD SR 2023-24 V0l -II Item No. 8.8 Page No. 42 | Sqm | 389.55 | 389.55 | 177.305 | False | None | None | False | None | False | 69069.16275 | 0 |
| 2649032 | 82622 | None | code57 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. PWD SR 2023-24 Vol -II Item No. 8.1.2 Page No. 41 PWD SR 2023-24 Vol -II Item No. 8.1.2 Page No. 41 | Sqm | 253.05 | 253.05 | 238.333 | False | None | None | False | None | False | 60310.16565 | 0 |
| 2649033 | 82622 | None | code58 | providing and laying Polished Granite stone flooring in required design
and patterns, in linear as well as curvilinear portions of the building all
complete as per the architectural drawings with 18 mm thick stone slab
over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4
coarse sand) laid and jointed with cement slurry and pointing with white
cement slurry admixed with pigment of matching shade including rubbing,
curing and polishing etc. all complete as specified and as directed by the
Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. PWD SR 2023-24 V -II Item No. 9.24 Page No. 63 PWD SR 2023-24 V -II Item No. 9.24 Page No. 63 | Cum | 2994.6 | 2994.6 | 75.9945 | False | None | None | False | None | False | 227573.1297 | 0 |
| 2649034 | 82622 | None | code59 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg/m2, including pointing in white cement mixed with pigment of matching shade complete PWD SR 2023-24 V -II Item No. 10.14 Page No. 71 PWD SR 2023-24 V -II Item No. 10.14 Page No. 71 | Sqm | 1161.3 | 1161.3 | 13.05 | False | None | None | False | None | False | 15154.965 | 0 |
| 2649035 | 82622 | None | code60 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per pecifications and as per directions of Engineer in charge. PWD SR 2023-24 V -II Item No. 8.51 Page No. 50 PWD SR 2023-24 V -II Item No. 8.51 Page No. 50 | Sqm | 105.0 | 105.0 | 334.243 | False | None | None | False | None | False | 35095.515 | 0 |
| 2649036 | 82622 | None | code61 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. PWD SR 2023-24 V -II Item No. 8.39 Page No. 48 PWD SR 2023-24 V -II Item No. 8.39 Page No. 48 | Sqm | 133.35 | 133.35 | 334.243 | False | None | None | False | None | False | 44571.30405 | 0 |
| 2649037 | 82622 | None | code62 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to move all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. PWD SR 2021-22 V -II Item No.8.31 Page No. 46 PWD SR 2023-24 V -II Item No.8.31 Page No. 46 | Sqm | 186.9 | 186.9 | 177.305 | False | None | None | False | None | False | 33138.3045 | 0 |
| 2649038 | 82622 | None | code63 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. PWD SR 2023-24 V -II Item No.8.33.3 Page No. 47 PWD SR 2023-24 V -II Item No.8.33.3 Page No. 47 | Sqm | 145.95 | 145.95 | 14.715 | False | None | None | False | None | False | 2147.65425 | 0 |
| 2649039 | 82622 | None | code64 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. PWD SR 2023-24 V -I Item No. 2.11.a Page No. 18 PWD SR 2023-24 V -I Item No. 2.11.a Page No. 18 | Tonne | 93929.85 | 93929.85 | 2.5168 | False | None | None | False | None | False | 236402.64648 | 0 |
| 2649040 | 82622 | None | code65 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. PWD SR 2023-24 V -II Item No.11.28 Page No. 85 PWD SR 2023-24 V -II Item No.11.28 Page No. 85 | Kg | 593.25 | 593.25 | 22.68 | False | None | None | False | None | False | 13454.91 | 0 |
| 2649041 | 82622 | None | code66 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter PWD SR 2023-24 V -II Item No-13.48 Page No -125 | Mtr | 305.55 | 305.55 | 15.0 | False | None | None | False | None | False | 4583.25 | 0 |
| 2649042 | 82622 | None | code67 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, if c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipes PWD SR 2023-24 V -II Item No-13.32.2 Page No -122 | Mtr | 397.95 | 397.95 | 15.0 | False | None | None | False | None | False | 5969.25 | 0 |
| 2649043 | 82622 | None | code68 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, if c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia pipes PWD SR 2023-24 V -II Item No-13.32.4 Page No -122 | Mtr | 584.85 | 584.85 | 20.0 | False | None | None | False | None | False | 11697.0 | 0 |
| 2649044 | 82622 | None | code69 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required 14.2.1 W.C. pan with ISI marked white solid plastic seat and lid PWD SR 2023-24 V -II Item No-14.2.1 Page No-131 | Each | 5079.9 | 5079.9 | 2.0 | False | None | None | False | None | False | 10159.8 | 0 |
| 2649045 | 82622 | None | code70 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 14.7.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps PWD SR 2023-24 V -II Item No-14.7.1 Page No-132 | Each | 3236.1 | 3236.1 | 2.0 | False | None | None | False | None | False | 6472.2 | 0 |
| 2649046 | 82622 | None | code71 | Providing and fixing brass stop cock of approved quality : 13.3.2 20 mm nominal bore PWD SR 2023-24 V -II Item No-13.3.2 Page No-117 | Each | 320.25 | 320.25 | 4.0 | False | None | None | False | None | False | 1281.0 | 0 |
| 2649047 | 82622 | None | code72 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 13.5.3 25 mm nominal bore PWD SR 2023-24 V -II Item No-13.5.3 Page No-117 | Each | 348.6 | 348.6 | 2.0 | False | None | None | False | None | False | 697.2 | 0 |
| 2649048 | 82622 | None | code73 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base suooort for tank. PWD SR 2023-24 V -II Item No-13.34 Page No -123 | Ltr | 9.45 | 9.45 | 20000.0 | False | None | None | False | None | False | 189000.0 | 0 |
| 2649049 | 82622 | None | code74 | Providing and fixing unplasticised PVC connection pipe with brass unions : 45 cm length
13.8.2.1 15 mm nominal bore ( item no 13.8.2.1 ) page no 118 PWP. DSR 2023-24 Vol-II | Each | 95.55 | 95.55 | 2.0 | False | None | None | False | None | False | 191.1 | 0 |
| 2649050 | 82622 | None | code75 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. ( item no 14.31 ) page no 136 PWP. DSR 2023-24 Vol-II | Each | 1281.0 | 1281.0 | 2.0 | False | None | None | False | None | False | 2562.0 | 0 |
| 2649051 | 82622 | None | code76 | Providing and fixing 100 mm sand cast Iron grating for gully trap. PWD SR 2023-24 V -II Item No-14.29 Page No-136 | Each | 49.35 | 49.35 | 2.0 | False | None | None | False | None | False | 98.7 | 0 |
| 2649052 | 82622 | None | code77 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth PWD SR 2023-24 V -IItem No-1.14.1 Page No-08 | Cum | 107.1 | 107.1 | 73.215 | False | None | None | False | None | False | 7841.3265 | 0 |
| 2649053 | 82622 | None | code78 | Providing Brick work with common burnt clay machine moulded perforated bricks of class designation 3.5 in superstructure above plinth level in cement mortar 1:6 (1 cement : 6 coarse sand) With Non modular bricks including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. PWD SR 2023-24 V -II Item No-6.8 Page No-14 | Cum | 8367.45 | 8367.45 | 0.828 | False | None | None | False | None | False | 6928.2486 | 0 |
| 2649054 | 82622 | None | code79 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. PWD SR 2023-24 V -II Item No-8.9 Page No-42 | Sqm | 404.25 | 404.25 | 12.64 | False | None | None | False | None | False | 5109.72 | 0 |
| 2649055 | 82622 | None | code80 | Providing and laying 100mm thick pre-cast cover slabs over drains & Rain pit of width not exceeding 800 mm using M20 concrete reinforced with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00 kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. PWD SR 2023-24 V -II Item No-17.12 Page No-176 | Cum | 974.4 | 974.4 | 1.3778 | False | None | None | False | None | False | 1342.52832 | 0 |
| 2649056 | 82622 | None | code81 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe32 mm dia ( item no 14.28.2.1 ) page no 136 PWP. DSR 2023-24 V -II | Mtr | 96.6 | 96.6 | 2.0 | False | None | None | False | None | False | 193.2 | 0 |
| 2649057 | 82622 | None | code82 | Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 19/20mm dia 2mm thick. (Electrical PWD SR 2023-24 PG No.2 ITNO. 1.1.1) | Mtr | 69.0 | 69.0 | 100.0 | False | None | None | False | None | False | 6900.0 | 0 |
| 2649058 | 82622 | None | code83 | Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25mm dia 2mm thick. (Electrical PWD SR 2023-24 PG No.2 ITNO. 1.1.2) | Mtr | 81.0 | 81.0 | 100.0 | False | None | None | False | None | False | 8100.0 | 0 |
| 2649059 | 82622 | None | code84 | Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 32mm dia 2.5mm thick. (Electrical PWD SR 2023-24 PG No.2 ITNO. 1.1.3) | Mtr | 106.0 | 106.0 | 30.0 | False | None | None | False | None | False | 3180.0 | 0 |
| 2649060 | 82622 | None | code85 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing Uor J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 19/20mm dia 2mm thick (Electrical PWD SR 2023-24 PG No.2 ITNO. 1.3.1) | Mtr | 68.0 | 68.0 | 30.0 | False | None | None | False | None | False | 2040.0 | 0 |
| 2649061 | 82622 | None | code86 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing Uor J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25mm dia 2mm thick (Electrical PWD SR 2023-24 PG No.2 ITNO. 1.3.2) | Mtr | 79.0 | 79.0 | 150.0 | False | None | None | False | None | False | 11850.0 | 0 |
| 2649062 | 82622 | None | code87 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing Uor J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary 32mm dia 2.5mm thick (Electrical PWD SR 2023-24 PG No.2 ITNO. 1.3.3) | Mtr | 99.0 | 99.0 | 50.0 | False | None | None | False | None | False | 4950.0 | 0 |
| 2649063 | 82622 | None | code88 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, screws at an interval of 300mm …. etc. as required.25mm (Electrical PWD SR 2023-24 PG No.3 ITNO. 1.8.2) | Mtr | 35.0 | 35.0 | 1000.0 | False | None | None | False | None | False | 35000.0 | 0 |
| 2649064 | 82622 | None | code89 | Supplying And Fixing Metal Fan Box with Round Hook (Electrical PWD SR 2023-24 PG No.4 ITNO. 1.13) | No | 117.0 | 117.0 | 2.0 | False | None | None | False | None | False | 234.0 | 0 |
| 2649065 | 82622 | None | code90 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. GROUP A 2.2.1 Short point upto 3m from tapping point to out let via switch box (Electrical PWD SR 2023-24 PG No.05 ITNO.2.2.1) | Point | 269.0 | 269.0 | 10.0 | False | None | None | False | None | False | 2690.0 | 0 |
| 2649066 | 82622 | None | code91 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. GROUP A
2.2.2 Medium point above 3m upto 6m from tapping point to out let via switch box (Electrical PWD SR 2023-24 PG No.05 ITNO.2.2.2) | Point | 379.0 | 379.0 | 10.0 | False | None | None | False | None | False | 3790.0 | 0 |
| 2649067 | 82622 | None | code92 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. GROUP A Long point above 6m upto 10m from tapping point to out let via switch box (Electrical PWD SR 2023-24 PG No.05 ITNO.2.2.3) | Point | 555.0 | 555.0 | 10.0 | False | None | None | False | None | False | 5550.0 | 0 |
| 2649068 | 82622 | None | code93 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. GROUP A
Two outlet in a row, above 3m upto 6m from tapping point to out let via switches (Electrical PWD SR 2023-24 PG No.05 ITNO.2.2.4) | Point | 677.0 | 677.0 | 10.0 | False | None | None | False | None | False | 6770.0 | 0 |
| 2649069 | 82622 | None | code94 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. GROUP A
Three outlet in a row, above 6m upto 10m from tapping point to out let via switches box (Electrical PWD SR 2023-24 PG No.05 ITNO.2.2.5) | Point | 989.0 | 989.0 | 10.0 | False | None | None | False | None | False | 9890.0 | 0 |
| 2649070 | 82622 | None | code95 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
2.3.2 1.5 mm2 (Electrical PWD SR 2023-24 PG No.05 ITNO.2.3.2) | Mtr | 26.0 | 26.0 | 100.0 | False | None | None | False | None | False | 2600.0 | 0 |
| 2649071 | 82622 | None | code96 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.2.3.3 2.5 mm2 (Electrical PWD SR 2023-24 PG No.05 ITNO.2.3.3) | Mtr | 42.0 | 42.0 | 200.0 | False | None | None | False | None | False | 8400.0 | 0 |
| 2649072 | 82622 | None | code97 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.3.4 4 mm2 (Electrical PWD SR 2023-24 PG No.05 ITNO.2.3.4) | Mtr | 63.0 | 63.0 | 200.0 | False | None | None | False | None | False | 12600.0 | 0 |
| 2649073 | 82622 | None | code98 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.2.3.5 6 mm2 (Electrical PWD SR 2023-24 PG No.05 ITNO.2.3.5) | Mtr | 92.0 | 92.0 | 100.0 | False | None | None | False | None | False | 9200.0 | 0 |
| 2649074 | 82622 | None | code99 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, ultistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 2.3.6 10 mm2 (Electrical PWD SR 2023-24 PG No.06 ITNO.2.3.6) | Mtr | 167.0 | 167.0 | 100.0 | False | None | None | False | None | False | 16700.0 | 0 |
| 2649075 | 82622 | None | code100 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.1 1-2Way (Electrical PWD SR 2023-24 PG No.08 ITNO.3.4.1) | Each | 138.0 | 138.0 | 10.0 | False | None | None | False | None | False | 1380.0 | 0 |
| 2649076 | 82622 | None | code101 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.4 6 Way (Electrical PWD SR 2023-24 PG No.08 ITNO.3.4.4) | Each | 220.0 | 220.0 | 10.0 | False | None | None | False | None | False | 2200.0 | 0 |
| 2649077 | 82622 | None | code102 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.5 8 Way (Electrical PWD SR 2023-24 PG No.08 ITNO.3.4.5) | Each | 261.0 | 261.0 | 5.0 | False | None | None | False | None | False | 1305.0 | 0 |
| 2649078 | 82622 | None | code103 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3.4.6 10-12 Way (Electrical PWD SR 2023-24 PG No.08 ITNO.3.4.6) | Each | 319.0 | 319.0 | 5.0 | False | None | None | False | None | False | 1595.0 | 0 |
| 2649079 | 82622 | None | code104 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3.5.1 1 to 2 Module (Electrical PWD SR 2023-24 PG No.08 ITNO.3.5.1) | Each | 137.0 | 137.0 | 5.0 | False | None | None | False | None | False | 685.0 | 0 |
| 2649080 | 82622 | None | code105 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module (Electrical PWD SR 2023-24 PG No.08 ITNO.3.5.4) | Each | 234.0 | 234.0 | 10.0 | False | None | None | False | None | False | 2340.0 | 0 |
| 2649081 | 82622 | None | code106 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module (Electrical PWD SR 2023-24 PG No.08 ITNO.3.5.5) | Each | 284.0 | 284.0 | 5.0 | False | None | None | False | None | False | 1420.0 | 0 |
| 2649082 | 82622 | None | code107 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module (Electrical PWD SR 2023-24 PG No.08 ITNO.3.5.6) | Each | 344.0 | 344.0 | 1.0 | False | None | None | False | None | False | 344.0 | 0 |
| 2649083 | 82622 | None | code108 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.1 6A One Way Switch (Electrical PWD SR 2023-24 PG No.09 ITNO.3.6.1) | Each | 102.0 | 102.0 | 1.0 | False | None | None | False | None | False | 102.0 | 0 |
| 2649084 | 82622 | None | code109 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.3 6A Three Way socket (Electrical PWD SR 2023-24 PG No.09 ITNO.3.6.3) | Each | 171.0 | 171.0 | 1.0 | False | None | None | False | None | False | 171.0 | 0 |
| 2649085 | 82622 | None | code110 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.4 Stepped Fan Regulator Two Module (Electrical PWD SR 2023-24 PG No.09 ITNO.3.6.4) | Each | 357.0 | 357.0 | 1.0 | False | None | None | False | None | False | 357.0 | 0 |
| 2649086 | 82622 | None | code111 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16A One Way Switch (Electrical PWD SR 2023-24 PG No.09 ITNO.3.6.7) | Each | 180.0 | 180.0 | 1.0 | False | None | None | False | None | False | 180.0 | 0 |
| 2649087 | 82622 | None | code112 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16A Universal Socket (Electrical PWD SR 2023-24 PG No.09 ITNO.3.6.10) | Each | 236.0 | 236.0 | 1.0 | False | None | None | False | None | False | 236.0 | 0 |
| 2649088 | 82622 | None | code113 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TV/Telephone Socket (Electrical PWD SR 2023-24 PG No.09 ITNO.3.6.11) | Each | 156.0 | 156.0 | 1.0 | False | None | None | False | None | False | 156.0 | 0 |
| 2649089 | 82622 | None | code114 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. II - Double Door 4 Way SP & N (Electrical PWD SR 2023-24 PG No.18 ITNO.5.19.6) | Each | 1524.0 | 1524.0 | 1.0 | False | None | None | False | None | False | 1524.0 | 0 |
| 2649090 | 82622 | None | code115 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. II - Double Door 6 Way SP & N (Electrical PWD SR 2023-24 PG No.18 ITNO.5.19.7) | Each | 1791.0 | 1791.0 | 1.0 | False | None | None | False | None | False | 1791.0 | 0 |
| 2649091 | 82622 | None | code116 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP (Electrical PWD SR 2023-24 PG No.17 ITNO.5.18.1) | Each | 415.0 | 415.0 | 1.0 | False | None | None | False | None | False | 415.0 | 0 |
| 2649092 | 82622 | None | code117 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A TPN (Electrical PWD SR 2023-24 PG No.17 ITNO.5.18.7) | Each | 1717.0 | 1717.0 | 1.0 | False | None | None | False | None | False | 1717.0 | 0 |
| 2649093 | 82622 | None | code118 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board. 5.20.3 32-40 A 4 pole (Electrical PWD SR 2020-21 PG No.13 ITNO.5.20.3) | Each | 2826.0 | 2826.0 | 1.0 | False | None | None | False | None | False | 2826.0 | 0 |
| 2649094 | 82622 | None | code119 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board. 5.20.4 63 A 4 pole (Electrical PWD SR 2020-21 PG No.13 ITNO.5.20.4) | Each | 3058.0 | 3058.0 | 1.0 | False | None | None | False | None | False | 3058.0 | 0 |
| 2649095 | 82622 | None | code120 | Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB ). The entire plug and socket shall be mounted in a thermoplastic / powder coated metal box & wired Completely. SP & N SP & N 5.45.2 20 A (Electrical PWD SR 2023-24 PG No.21 ITNO.5.45.2) | Each | 971.0 | 971.0 | 1.0 | False | None | None | False | None | False | 971.0 | 0 |
| 2649096 | 82622 | None | code121 | Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB ). The entire plug and socket shall be mounted in a thermoplastic / powder coated metal box & wired Completely. SP & N TP & N 5.45.3 20 A (Electrical PWD SR 2023-24 PG No.21 ITNO.5.45.3) | Each | 1340.0 | 1340.0 | 2.0 | False | None | None | False | None | False | 2680.0 | 0 |
| 2649097 | 82622 | None | code122 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 32.11 50 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm) (Electrical Commom SR 2023-24 PG No.13 ITNO.32.11) | Km | 178973.0 | 178973.0 | 0.05 | False | None | None | False | None | False | 8948.65 | 0 |
| 2649098 | 82622 | None | code123 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable
21.06 35 to 95 Sqmm (Electrical Commom SR 2023-24 PG No.52 ITNO.21.06) | Km | 31139.0 | 31139.0 | 0.05 | False | None | None | False | None | False | 1556.95 | 0 |
| 2649099 | 82622 | None | code124 | Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. 29.03 In Hard Soil (Electrical Commom SR 2023-24 PG No.10 ITNO.1.19.1) | Cum | 454.0 | 454.0 | 30.0 | False | None | None | False | None | False | 13620.0 | 0 |
| 2649100 | 82622 | None | code125 | Refilling the cable trenches with selected available earth from trench excavation including watering, consolidation in layers of 15 cm. Thickness including depositing of the surplus earth with a lead of 200 Mtr (Electrical Commom SR 2023-24 PG No.07 ITNO.1.10) | Cum | 160.0 | 160.0 | 30.0 | False | None | None | False | None | False | 4800.0 | 0 |
| 2649101 | 82622 | None | code126 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. GI Wire 6.18.3 8 SWG GI Wire (PWD Electrical SR 2019-20 PG No.44 ITNO.6.18.3) | Mtr | 19.0 | 19.0 | 100.0 | False | None | None | False | None | False | 1900.0 | 0 |
| 2649102 | 82622 | None | code127 | Gescom Deposit | LS | 20000.0 | 20000.0 | 1.0 | False | None | None | False | None | False | 20000.0 | 0 |
| 2649103 | 82622 | None | code128 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth PWD SR 2021-22 V -1 Item No. 1.12 Page No. 08 | Cum | 99.75 | 99.75 | 97.5 | False | None | None | False | None | False | 9725.625 | 0 |
| 2649104 | 82622 | None | code129 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m PWD SR 2021-22 V -1 Item No. 1.14.1 Page No. 08 | Cum | 107.1 | 107.1 | 37.6531 | False | None | None | False | None | False | 4032.64701 | 0 |
| 2649105 | 82622 | None | code130 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m PWD SR 2021-22 V -1 Item No. 1.14.1 Page No. 08 | Cum | 107.1 | 107.1 | 158.565 | False | None | None | False | None | False | 16982.3115 | 0 |
| 2649106 | 82622 | None | code131 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates PWD SR 2021-22 V -1 Item No. 2.1.3 Page No. 15 | Cum | 6288.45 | 6288.45 | 37.1057 | False | None | None | False | None | False | 233337.339165 | 0 |
| 2649107 | 82622 | None | code132 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD SR 2021-22 V -1 Item No. 2.3.1 Page No. 16 | Cum | 6639.15 | 6639.15 | 28.5355 | False | None | None | False | None | False | 189451.464825 | 0 |
| 2649108 | 82622 | None | code133 | Add 8% for Formwork, Addendum-I | Cum | 531.13 | 531.13 | 28.5355 | False | None | None | False | None | False | 15156.060115 | 0 |
| 2649109 | 82622 | None | code134 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) 2.3.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD SR 2021-22 V -1 Item No. 2.3.2 Page No. 16 | Cum | 6804.0 | 6804.0 | 10.7225 | False | None | None | False | None | False | 72955.89 | 0 |
| 2649110 | 82622 | None | code135 | Add 70% for Formwork, Addendum-I | Cum | 4762.8 | 4762.8 | 10.7225 | False | None | None | False | None | False | 51069.123 | 0 |
| 2649111 | 82622 | None | code136 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) 2.3.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD SR 2021-22 V -1 Item No. 2.3.2 Page No. 16 | Cum | 6804.0 | 6804.0 | 17.8453 | False | None | None | False | None | False | 121419.4212 | 0 |
| 2649112 | 82622 | None | code137 | Add 50% for Formwork, Addendum-I | Cum | 3402.0 | 3402.0 | 17.8453 | False | None | None | False | None | False | 60709.7106 | 0 |
| 2649113 | 82622 | None | code138 | Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) PWD SR 2021-22 V -II Item No. 5.3 Page No. 9 | Cum | 6515.25 | 6515.25 | 27.5913 | False | None | None | False | None | False | 179764.217325 | 0 |
| 2649114 | 82622 | None | code139 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) PWD SR 2021-22 V -II Item No. 5.4 Page No. 9 | Cum | 6708.45 | 6708.45 | 20.9761 | False | None | None | False | None | False | 140717.118045 | 0 |
| 2649115 | 82622 | None | code140 | Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge. PWD SR 2021-22 V -II Item No. 8.19.1 Page No. 44 | Sqm | 267.75 | 267.75 | 31.6935 | False | None | None | False | None | False | 8485.934625 | 0 |
| 2649116 | 82622 | None | code141 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. PWD SR 2021-22 V -I Item No. 1.9 Page No. 7 | Cum | 279.3 | 279.3 | 347.2561 | False | None | None | False | None | False | 96988.62873 | 0 |
| 2649117 | 82622 | None | code142 | Providing Brick work with common burnt clay modular bricks of classdesignation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement: 4 coarse sand) including cost of all materials, labour, scaffolding andusage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. PWD SR 2021-22 V -II Item No. 6.2 Page No. 13 | Cum | 8376.9 | 8376.9 | 45.5552 | False | None | None | False | None | False | 381611.35488 | 0 |
| 2649118 | 82622 | None | code143 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm ominal size graded crushed coarse aggregates PWD SR 2021-22 V -I Item No. 2.5.1 Page No. 16 | Cum | 6961.5 | 6961.5 | 0.207 | False | None | None | False | None | False | 1441.0305 | 0 |
| 2649119 | 82622 | None | code144 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super lasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD SR 2021-22 V -I Item No. 2.5.1 Page No. 16 | Cum | 6961.5 | 6961.5 | 1.9039 | False | None | None | False | None | False | 13253.99985 | 0 |
| 2649120 | 82622 | None | code145 | Add 60% for Formwork, Addendum-I | Cum | 4176.9 | 4176.9 | 1.9039 | False | None | None | False | None | False | 7952.39991 | 0 |
| 2649121 | 82622 | None | code146 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, uring and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD SR 2021-22 V -I Item No. 2.5.1 Page No. 16 | Cum | 6961.5 | 6961.5 | 0.648 | False | None | None | False | None | False | 4511.052 | 0 |
| 2649122 | 82622 | None | code147 | Add 45% for Formwork, Addendum-I | Cum | 3132.68 | 3132.68 | 0.648 | False | None | None | False | None | False | 2029.97664 | 0 |
| 2649123 | 82622 | None | code148 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super lasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, uring and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm ominal size graded crushed coarse aggregates PWD SR 2021-22 V -I Item No. 2.5.1 Page No. 16 | Cum | 6961.5 | 6961.5 | 15.2625 | False | None | None | False | None | False | 106249.89375 | 0 |
| 2649124 | 82622 | None | code149 | Add 60% for Formwork, Addendum-I | Cum | 4176.9 | 4176.9 | 15.2625 | False | None | None | False | None | False | 63749.93625 | 0 |
| 2649125 | 82622 | None | code150 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super lasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD SR 2021-22 V -I Item No. 2.5.1 Page No. 16 | Cum | 6961.5 | 6961.5 | 38.8603 | False | None | None | False | None | False | 270525.97845 | 0 |
| 2649126 | 82622 | None | code151 | Add 50% for Formwork, Addendum-I | Cum | 3480.75 | 3480.75 | 38.8603 | False | None | None | False | None | False | 135262.989225 | 0 |
| 2649127 | 82622 | None | code152 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour,curing complete as per specifications and as per directions of Engineer-in-charge. PWD SR 2021-22 V -II Item No. 8.10 Page No. 43 | Sqm | 221.55 | 221.55 | 299.296 | False | None | None | False | None | False | 66309.0288 | 0 |
| 2649128 | 82622 | None | code153 | Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. PWD SR 2021-22 V -II Item No. 12.11 Page No. 99 | Cum | 144977.7 | 144977.7 | 0.22 | False | None | None | False | None | False | 31895.094 | 0 |
| 2649129 | 82622 | None | code154 | Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures ) PWD SR 2021-22 V -II Item No. 12.15 Page No. 100 | Sqm | 7816.2 | 7816.2 | 9.24 | False | None | None | False | None | False | 72221.688 | 0 |
| 2649130 | 82622 | None | code155 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. PWD SR 2021-22 V -II Item No. 11.34 B Page No. 86 | Kg | 192.15 | 192.15 | 340.2 | False | None | None | False | None | False | 65369.43 | 0 |
| 2649131 | 82622 | None | code156 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile hrough-out the window frame The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm nd mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) PWD SR 2021-22 V -II Item No. 12.90 B Page No. 110 | Sqm | 7070.7 | 7070.7 | 16.2 | False | None | None | False | None | False | 114545.34 | 0 |
| 2649132 | 82622 | None | code157 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement ortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever equired smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. PWD SR 2021-22 V -II Item No. 8.8 Page No. 42 | Sqm | 389.55 | 389.55 | 276.508 | False | None | None | False | None | False | 107713.6914 | 0 |
| 2649133 | 82622 | None | code158 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, uring complete as per specifications and as per directions of Engineer-in-charge. PWD SR 2021-22 V -II Item No. 8.1.2 Page No. 41 | Sqm | 253.05 | 253.05 | 289.38 | False | None | None | False | None | False | 73227.609 | 0 |
| 2649134 | 82622 | None | code159 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm PWD SR 2021-22 V -II Item No. 9.17.2 Page No. 61 | Sqm | 1233.75 | 1233.75 | 294.3354 | False | None | None | False | None | False | 363136.29975 | 0 |
| 2649135 | 82622 | None | code160 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per pecifications and as per directions of Engineer in charge. PWD SR 2021-22 V -II Item No. 8.51 Page No. 50 | Sqm | 105.0 | 105.0 | 588.676 | False | None | None | False | None | False | 61810.98 | 0 |
| 2649136 | 82622 | None | code161 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per pecifications and as per directions of Engineer-in-charge. PWD SR 2021-22 V -II Item No. 8.39 Page No. 48 | Sqm | 133.35 | 133.35 | 588.676 | False | None | None | False | None | False | 78499.9446 | 0 |
| 2649137 | 82622 | None | code162 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to move all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. PWD SR 2021-22 V -II Item No.8.31 Page No. 46 | Sqm | 186.9 | 186.9 | 276.508 | False | None | None | False | None | False | 51679.3452 | 0 |
| 2649138 | 82622 | None | code163 | Painting wood work with Deluxe Multi Surface Paint of required
shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer
applied @0.75 ltr/10 m² of approved brand and manufacture to give an
even shade including preparing the surface after thorougly cleaning
oil, grease, dirt and foreign matter, sand papering and knotting , cost of
materials, labour complete as per specifications and as per directions
of Engineer-in-charge. PWD SR 2021-22 V -II Item No.8.33.2 Page No. 46 | Sqm | 144.9 | 144.9 | 24.024 | False | None | None | False | None | False | 3481.0776 | 0 |
| 2649139 | 82622 | None | code164 | Painting Steel work with Deluxe Multi Surface Paint to give an even
shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer
applied @ 0.80 ltr/10 m² of approved brand and manufacture including
preparing the surface after thorougly cleaning oil, grease, dirt and foreign
matter, cost of materials, labour complete as per specifications and as
per directions of Engineer-in-charge PWD SR 2021-22 V -II Item No.8.33.3 Page No. 47 | Sqm | 145.95 | 145.95 | 16.2 | False | None | None | False | None | False | 2364.39 | 0 |
| 2649140 | 82622 | None | code165 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Building PWD SR 2021-22 V -I Item No.2.11.a Page No. 18 | Tonne | 93929.85 | 93929.85 | 9.8092 | False | None | None | False | None | False | 921376.68462 | 0 |