tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1708584944000 | 0 | None | None | Electrical | line Supply Portion | 3624936.98 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2750021 | 87599 | None | DVG01 | Supply of Tower parts
Fabrication and Supply of galvanised 66 KV DC Towers (Kalpataru Design)
Note: Erection under LC condition.
Tower type 66kV DC-B with stubs
a) DB+3 Mtrs Extension (2.029 MT Per Tower)
b) DB+6 Mtrs Extension (2.416 MT Per Tower
Tower type 66kV DC-D with stubs
a) DD+0 Mtrs (2.487 MT Per Tower)
b) DD+3 Mtrs Extension (3.030 MT Per Tower)
Fabrication and Supply of galvanised 66 KV DC Narrow based Towers (KPTCL Design).
Tower type 66 kV DC(NB)-D
a) DD+0 with 9 cross arm (4.762 MT Per Tower) | MT | 135520.0 | 135520.0 | 17.211 | False | None | None | False | None | False | 2332434.72 | 0 | 2750022 | 87599 | None | DVG02 | Supply of Galvanised Bolts & Nuts | MT | 142780.0 | 142780.0 | 0.607 | False | None | None | False | None | False | 86667.46 | 0 | 2750023 | 87599 | None | DVG03 | Tower accessories :
Number Plates | No | 327.8 | 327.8 | 6.0 | False | None | None | False | None | False | 1966.8 | 0 | 2750024 | 87599 | None | DVG04 | Danger Boards | No | 318.4 | 318.4 | 6.0 | False | None | None | False | None | False | 1910.4 | 0 | 2750025 | 87599 | None | DVG05 | Circuit plate | No | 318.0 | 318.0 | 12.0 | False | None | None | False | None | False | 3816.0 | 0 | 2750026 | 87599 | None | DVG06 | Phase plate (Set of 3No.) | Set | 264.0 | 264.0 | 12.0 | False | None | None | False | None | False | 3168.0 | 0 | 2750027 | 87599 | None | DVG07 | Earth bond 450 mm long | No | 533.0 | 533.0 | 6.0 | False | None | None | False | None | False | 3198.0 | 0 | 2750028 | 87599 | None | DVG08 | Conductor & Ground wire :
Coyote ACSR: Plain Terrian under SHUT DOWN condition. (Route length of 0.382Kms) | Km | 139000.0 | 139000.0 | 2.3263 | False | None | None | False | None | False | 323355.7 | 0 | 2750029 | 87599 | None | DVG09 | Coyote ACSR: Plain Terrian under SHUT DOWN condition. (Route length of 0.391 Kms)
(Stringing from DD+0 (LILO tower) to Loc No.65 proposed DB+3 & DD+0 (LILO tower) to Loc No.66 proposed DB+6 in the existing 66KV Honnali-Malebennur DC line) | Km | 139000.0 | 139000.0 | 2.3811 | False | None | None | False | None | False | 330972.9 | 0 | 2750030 | 87599 | None | DVG10 | 7/3.15mm Ground Wire: Plain Terrian under SHUT DOWN condition. (Route length of 0.382Kms) | Km | 88000.0 | 88000.0 | 0.3877 | False | None | None | False | None | False | 34117.6 | 0 | 2750031 | 87599 | None | DVG11 | 7/3.15mm Ground Wire: Plain Terrian under SHUT DOWN condition.
(Route length of 0.391 Kms)
(Stringing from DD+0 (LILO tower) to Loc No.65 proposed DB+3 & DD+0 (LILO tower) to Loc No.66 proposed DB+6 in the existing 66KV Honnali-Malebennur DC line) | Set | 88000.0 | 88000.0 | 0.3968 | False | None | None | False | None | False | 34918.4 | 0 | 2750032 | 87599 | None | DVG12 | Single tension strings with Silicon Rubber composite Insulator 90KN (5 Nos of Disc for Coyote Conductor) with hard wares for coyote ACSR and arcing horn Complete. | Stack | 4032.0 | 4032.0 | 75.0 | False | None | None | False | None | False | 302400.0 | 0 | 2750033 | 87599 | None | DVG13 | Single Suspension strings with Silicon Rubber composite Insulator 90KN (4 Nos of Disc for Coyote Conductor) with hard wares for coyote ACSR and arcing horn Complete. | No. | 4250.0 | 4250.0 | 9.0 | False | None | None | False | None | False | 38250.0 | 0 | 2750034 | 87599 | None | DVG14 | Accessories for Conductor :
M.S.C joints for Coyote | No. | 621.0 | 621.0 | 6.0 | False | None | None | False | None | False | 3726.0 | 0 | 2750035 | 87599 | None | DVG15 | Repairs sleeves for coyote | No. | 300.0 | 300.0 | 6.0 | False | None | None | False | None | False | 1800.0 | 0 | 2750036 | 87599 | None | DVG16 | Vibration dampers for Coyote | No | 317.0 | 317.0 | 75.0 | False | None | None | False | None | False | 23775.0 | 0 | 2750037 | 87599 | None | DVG17 | P.G. Clamps for Coyote for jumps | Set | 916.0 | 916.0 | 90.0 | False | None | None | False | None | False | 82440.0 | 0 | 2750038 | 87599 | None | DVG18 | Hardware and Accessories for Ground Wire :
MSC joints for Ground Wire | Set | 457.0 | 457.0 | 4.0 | False | None | None | False | None | False | 1828.0 | 0 | 2750039 | 87599 | None | DVG19 | Repairs sleeves for Ground Wire | No | 1234.0 | 1234.0 | 4.0 | False | None | None | False | None | False | 4936.0 | 0 | 2750040 | 87599 | None | DVG20 | Tension clamp for Ground wire | Set | 309.0 | 309.0 | 13.0 | False | None | None | False | None | False | 4017.0 | 0 | 2750041 | 87599 | None | DVG21 | P.G. Clamps for Ground Wire for jumps | No | 403.0 | 403.0 | 13.0 | False | None | None | False | None | False | 5239.0 | 0 |
| 1708584944000 | 0 | None | None | Electrical | line Errection Portion | 571896.41 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2750042 | 87600 | None | DVG01 | Check survey using ther own equipment for 66 kV Plain terrain | Km | 2904.0 | 2904.0 | 0.382 | False | None | None | False | None | False | 1109.328 | 0 | 2750043 | 87600 | None | DVG02 | Supply of Tower parts
Fabrication and Supply of galvanised 66 KV DC Towers (Kalpataru Design)
Note: Erection under LC condition.
Tower type 66kV DC-B with stubs
a) DB+3 Mtrs Extension (2.029 MT Per Tower)
b) DB+6 Mtrs Extension (2.416 MT Per Tower)
Tower type 66kV DC-D with stubs
a) DD+0 Mtrs (2.487 MT Per Tower)
b) DD+3 Mtrs Extension (3.030 MT Per Tower)
Fabrication and Supply of galvanised 66 KV DC Narrow based Towers (KPTCL Design).
Tower type 66 kV DC(NB)-D
a) DD+0 with 9 cross arm (4.762 MT Per Tower)
Total Weight of Towers MS Portion: | MT | 6156.0 | 6156.0 | 17.211 | False | None | None | False | None | False | 105950.916 | 0 | 2750044 | 87600 | None | DVG03 | Setting of stub templates and aligning dismantling and transportaion of templates from one location to another location for 66 kV | No | 705.0 | 705.0 | 6.0 | False | None | None | False | None | False | 4230.0 | 0 | 2750045 | 87600 | None | DVG04 | Supply of Galvanised Bolts & Nuts | MT | 5723.0 | 5723.0 | 0.607 | False | None | None | False | None | False | 3473.861 | 0 | 2750046 | 87600 | None | DVG05 | Tower accessories :
Supplying and fixing GI angle 450 x 450 mm 1Mtr length with cleats, bolts nuts as per specification and fixing above 0.5 mts length each at inner and outer surface of tower to facilitate running of barbed wire AC device | Set | 4121.0 | 4121.0 | 6.0 | False | None | None | False | None | False | 24726.0 | 0 | 2750047 | 87600 | None | DVG06 | Supplying and fixing Barbed wire | Rmtr | 76.0 | 76.0 | 912.12 | False | None | None | False | None | False | 69321.12 | 0 | 2750048 | 87600 | None | DVG07 | Number Plates | No | 54.0 | 54.0 | 6.0 | False | None | None | False | None | False | 324.0 | 0 | 2750049 | 87600 | None | DVG08 | Danger Boards | No | 54.0 | 54.0 | 6.0 | False | None | None | False | None | False | 324.0 | 0 | 2750050 | 87600 | None | DVG09 | Circuit plate | No | 54.0 | 54.0 | 12.0 | False | None | None | False | None | False | 648.0 | 0 | 2750051 | 87600 | None | DVG10 | Phase plate (Set of 3No.) | Set | 161.0 | 161.0 | 12.0 | False | None | None | False | None | False | 1932.0 | 0 | 2750052 | 87600 | None | DVG11 | Grounding of tower with GI Pipe including the cost of 40mm dia 2.5 mm thick, class C GI pipe of 3 Mtrs length as per specifications, with 50x6 mm GI Flats 3 Mtr long, salt charcoal, including excavation charges. | Set | 7335.0 | 7335.0 | 6.0 | False | None | None | False | None | False | 44010.0 | 0 | 2750053 | 87600 | None | DVG12 | Conductor & Ground wire :
Coyote ACSR: Plain Terrian under SHUT DOWN condition. (Route length of 0.382Kms) | Km | 8000.0 | 8000.0 | 2.3263 | False | None | None | False | None | False | 18610.4 | 0 | 2750054 | 87600 | None | DVG13 | Coyote ACSR: Plain Terrian under SHUT DOWN condition. (Route length of 0.391 Kms)
(Stringing from DD+0 (LILO tower) to Loc No.65 proposed DB+3 & DD+0 (LILO tower) to Loc No.66 proposed DB+6 in the existing 66KV Honnali-Malebennur DC line) | Km | 8000.0 | 8000.0 | 2.3811 | False | None | None | False | None | False | 19048.8 | 0 | 2750055 | 87600 | None | DVG14 | 7/3.15mm Ground Wire: Plain Terrian under SHUT DOWN condition. (Route length of 0.382Kms) | Km | 11000.0 | 11000.0 | 0.3877 | False | None | None | False | None | False | 4264.7 | 0 | 2750056 | 87600 | None | DVG15 | 7/3.15mm Ground Wire: Plain Terrian under SHUT DOWN condition. (Route length of 0.391 Kms)
(Stringing from DD+0 (LILO tower) to Loc No.65 proposed DB+3 & DD+0 (LILO tower) to Loc No.66 proposed DB+6 in the existing 66KV Honnali-Malebennur DC line) | Set | 11000.0 | 11000.0 | 0.3968 | False | None | None | False | None | False | 4364.8 | 0 | 2750057 | 87600 | None | DVG16 | Tack welding for tower Bolts and Nuts (No. of tower X250) | No | 22.0 | 22.0 | 1500.0 | False | None | None | False | None | False | 33000.0 | 0 | 2750058 | 87600 | None | DVG17 | Releasing and re-stringing of Coyote conductor & ground wire in the existing lines:
Releasing and re-stringing of the COYOTE ACSR Conductor in the existing 66kV Honnali-Malebennur Line from 62 DB+0 to 65 proposed DB+3 in place of DA+3 and from 66 proposed DB+6 in place of DA+0 to 78 DB+0 (Route length 1.98 Km) | Km | 16000.0 | 16000.0 | 11.88 | False | None | None | False | None | False | 190080.0 | 0 | 2750059 | 87600 | None | DVG18 | Releasing and re-stringing of the GROUND Conductor in the existing 66kV Honnali-Malebennur Line from 62 DB+0 to 65 proposed DB+3 in place of DA+3 and from 66 proposed DB+6 in place of DA+0 to 78 DB+0 (Route length 1.98 Km) | Km | 22000.0 | 22000.0 | 1.98 | False | None | None | False | None | False | 43560.0 | 0 | 2750060 | 87600 | None | DVG19 | Clearing of Bushes, tree branches etc., upto 3 Mtr width for detailed survey 66kV Plain terrain(KPWD CSR Volume 1/ VI.21/P.No 126) | Km | 7640.0 | 7640.0 | 0.382 | False | None | None | False | None | False | 2918.48 | 0 |
| 1708584944000 | 0 | None | None | Electrical | line civil portion | 1615734.75 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2750061 | 87601 | None | DVG01 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights,including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth with 5% with de-watering is assessed as per site condition (VOL-I,KPWD SR 23-24 Page.No.8 Item No.1.15.1) | Cum | 390.1 | 390.1 | 754.5825 | False | None | None | False | None | False | 294362.63325 | 0 | 2750062 | 87601 | None | DVG02 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights,including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In ordinary/soft rock without blasting Depth exceeding 1.5 m but not exceeding 3 m depth with 7.5% with de-watering is assessed as per site condition (VOL-I,KPWD SR 23-24 Page.No.8 Item No.1.15.2) | Cum | 455.9 | 455.9 | 251.5275 | False | None | None | False | None | False | 114671.38725 | 0 | 2750063 | 87601 | None | DVG03 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per
technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)
Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse
aggregates (VOL-I,KPWD SR 22-23 Page.No.15 Item No.2.1.4) | Cum | 6217.0 | 6217.0 | 14.3799 | False | None | None | False | None | False | 89399.8383 | 0 | 2750064 | 87601 | None | DVG04 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)
M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregate with 3 % Form work (VOL-I,KPWD SR 23-24 Page.No.15 Item No.2.2.1) | Cum | 6789.96 | 6789.96 | 101.36 | False | None | None | False | None | False | 688230.3456 | 0 | 2750065 | 87601 | None | DVG05 | Providing Thermo-Mechanically Treated bars of grade Fe-550D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) (VOL-II,KPWD SR 23-24 Page.No.18 Item No.2.11.h) | Kg | 79.01 | 79.01 | 2433.01 | False | None | None | False | None | False | 192232.1201 | 0 | 2750066 | 87601 | None | DVG06 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm
in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.(VOl-1, KPWD SR 23-24 Page.No.7 Item No.1.9) | Cum | 266.0 | 266.0 | 890.37 | False | None | None | False | None | False | 236838.42 | 0 |
| 1708584944000 | 0 | None | None | Electrical | LINE Dismantling PORTION | 115275.05 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2750067 | 87602 | None | DVG01 | Dismantling of existing Towers | MT | 5723.0 | 5723.0 | 6.64 | False | None | None | False | None | False | 38000.72 | 0 | 2750068 | 87602 | None | DVG02 | Removing dismantled towers stubs upto a depth of 1 mtr by excavation and breaking the stub concrete & backfilling with the available soil complete; | No. | 5016.0 | 5016.0 | 5.0 | False | None | None | False | None | False | 25080.0 | 0 | 2750069 | 87602 | None | DVG03 | Releasing of Existing Coyote conductor along with Hardware (UNDER SHUT DOWN CONDITION) | Kms | 8000.0 | 8000.0 | 2.346 | False | None | None | False | None | False | 18768.0 | 0 | 2750070 | 87602 | None | DVG04 | Releasing of Existing Ground wire along with Hardware (UNDER SHUT DOWN CONDITION) | Kms | 11000.0 | 11000.0 | 0.391 | False | None | None | False | None | False | 4301.0 | 0 | 2750071 | 87602 | None | DVG05 | Dismantling of existing 03 No. Isolator (under Shut down condition) | No. | 4293.0 | 4293.0 | 3.0 | False | None | None | False | None | False | 12879.0 | 0 | 2750072 | 87602 | None | DVG06 | Dismantling of existing 03 No. Lightning Arrestor (under Shut down condition) | No. | 244.33 | 244.33 | 3.0 | False | None | None | False | None | False | 732.99 | 0 | 2750073 | 87602 | None | DVG07 | Dismantling of existing 03 No. Isolator support Structure (under Shut down condition)
= 85%*0.724*3Nos = 1.85 MT | MT | 5723.0 | 5723.0 | 1.8461 | False | None | None | False | None | False | 10565.2303 | 0 | 2750074 | 87602 | None | DVG08 | Dismantling of existing 03 No. Lightning arrestor support Structure (under Shut down condition) = 85% * 0.072 * 3 Nos = 0.14MT | MT | 5723.0 | 5723.0 | 0.1404 | False | None | None | False | None | False | 803.5092 | 0 | 2750075 | 87602 | None | DVG09 | Dismantling of existing 06 No. CT support Structure (under Shut down condition)= 85% * 0.142 * 6 Nos = 0.72MT | MT | 5723.0 | 5723.0 | 0.7242 | False | None | None | False | None | False | 4144.5966 | 0 |
| 1708584944000 | 0 | None | None | Electrical | TB Supply | 6079690.44 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2750076 | 87603 | None | DVG01 | CIRCUIT BREAKER : SF-6 circuit breakers with semi pneumatic / pneumatic operated / Spring type operating mechanism, including mounting structure with rigid, bi-metallic terminal connector suitable for Drake ACSR and mounting structure. (UNDER SHUTDOWN CONDITION)
66 kV, 1250 A, 31.5 KA Class
Line side | No. | 703010.0 | 703010.0 | 1.0 | False | None | None | False | None | False | 703010.0 | 0 | 2750077 | 87603 | None | DVG02 | ISOLATORS : Isolators including marshalling box, terminal connectors suitable for Drake ACSR and solid core cylindrical post insulators.
66 kV, 1250 A, 31.5 KA class double break manually operated isolator with solid core insulators (UNDER SHUTDOWN CONDITION)
Upright mounting type with Earth switch.LPH 4.60 Mtr. | Set | 278300.0 | 278300.0 | 1.0 | False | None | None | False | None | False | 278300.0 | 0 | 2750078 | 87603 | None | DVG03 | ISOLATORS : Isolators including marshalling box, terminal connectors suitable for Drake ACSR and solid core cylindrical post insulators.
66 kV, 1250 A, 31.5 KA class double break manually operated isolator with solid core insulators (UNDER SHUTDOWN CONDITION)
Upright mounting type without Earth switch.LPH 4.60 Mtr. | Set | 233530.0 | 233530.0 | 4.0 | False | None | None | False | None | False | 934120.0 | 0 | 2750079 | 87603 | None | DVG04 | CURRENT TRANSFORMER : Current transformer Single phase, oil filled outdoor type with rigid bimetallic terminal connectors suitable for Drake ACSR.
(UNDER SUTDOWN CONDITION)
66 kV class, 31.5 KA, CT of ratio 400-200 / 1-1-1A for Lines For metering : Accuracy 0.2, Burden 10 VAFor backup protection : Accuracy 5P20. Burden 30 VA For differential /Distance protection PS class | No. | 98010.0 | 98010.0 | 3.0 | False | None | None | False | None | False | 294030.0 | 0 | 2750080 | 87603 | None | DVG05 | SURGE ARRESTOR : (Procelain housing) metal oxide, Gapless type with rigid bimetallic connectors suitable for Drake ACSR.
60 kV, 10 KA, class - II, Normal duty Metal oxide type | No. | 31460.0 | 31460.0 | 6.0 | False | None | None | False | None | False | 188760.0 | 0 | 2750081 | 87603 | None | DVG06 | Control and Relay Panel- Simplex type 110 DC compatible to SCADA complete.: 66KV Transmission line panel Simplex type | No. | 456170.0 | 456170.0 | 1.0 | False | None | None | False | None | False | 456170.0 | 0 | 2750082 | 87603 | None | DVG07 | Equipments required for Integration of New Bay to Existing SCADA Panel as per KPTCL specification.
Multi Functional Transducers (MFT) 0.2 S including labour (market rate) | No | 4875.0 | 4875.0 | 1.0 | False | None | None | False | None | False | 4875.0 | 0 | 2750083 | 87603 | None | DVG08 | Opto Coupler (220V or 110V) with labour (market rate) | No | 1312.0 | 1312.0 | 1.0 | False | None | None | False | None | False | 1312.0 | 0 | 2750084 | 87603 | None | DVG09 | Currente cable - Copper core with c/s 7C X 4.0 Sqmm multistrand. | Mtr | 280.74 | 280.74 | 5.0 | False | None | None | False | None | False | 1403.7 | 0 | 2750085 | 87603 | None | DVG10 | Voltage cable - Copper core with c/s 4C X 2.5 Sqmm multistrand. | Mtr | 111.59 | 111.59 | 5.0 | False | None | None | False | None | False | 557.95 | 0 | 2750086 | 87603 | None | DVG11 | Signal Cable - Armoured Copper core with c/s 10C X 0.5 Sqmm multistrand. | Mtr | 143.0 | 143.0 | 5.0 | False | None | None | False | None | False | 715.0 | 0 | 2750087 | 87603 | None | DVG12 | Supply of Control cables copper core 10C X 1.5 Sq mm Multistrand, conforming to KPTCL specifications. | Mtr | 155.0 | 155.0 | 5.0 | False | None | None | False | None | False | 775.0 | 0 | 2750088 | 87603 | None | DVG13 | RJ 45 cable for Energy meter integration to DCU (Market rate ) | Mtr | 70.0 | 70.0 | 5.0 | False | None | None | False | None | False | 350.0 | 0 | 2750089 | 87603 | None | DVG14 | STATION STRUCTURES :
66KV side: station structure out of fabricated iron galvanized ( Appr. Unit wt. in MT add 5% for B&N) (UNDER SUTDOWN CONDITION)
Station Towers - ISMB 300x140 structure 12 meter long for column including angle iron cleats etc.,(0.54 MT) | No. | 77464.2 | 77464.2 | 2.0 | False | None | None | False | None | False | 154928.4 | 0 | 2750090 | 87603 | None | DVG15 | Station beams - ISMB 250x125 structure 7.9 meter long for Beam including angle iron cleats etc.,(0.2607 MT) | No. | 38899.57 | 38899.57 | 6.0 | False | None | None | False | None | False | 233397.42 | 0 | 2750091 | 87603 | None | DVG16 | Station towers (Verticals 6T1) (0.956 MT) | No. | 129819.69 | 129819.69 | 3.0 | False | None | None | False | None | False | 389459.07 | 0 | 2750092 | 87603 | None | DVG17 | Station beams (6B1) (0.504 MT) | No. | 68476.32 | 68476.32 | 2.0 | False | None | None | False | None | False | 136952.64 | 0 | 2750093 | 87603 | None | DVG18 | MOUNTING STRUCTURES :
(Unit wt. in MT add 5 % for B&N)
(UNDER SUTDOWN CONDITION)
66 kV Isolator Live point height 4600 mm.
(0.76 MT per Structure) | No. | 103256.56 | 103256.56 | 5.0 | False | None | None | False | None | False | 516282.8 | 0 | 2750094 | 87603 | None | DVG19 | 66 kV Current transformer
(0.149 MT per Structure) | No. | 20243.3 | 20243.3 | 9.0 | False | None | None | False | None | False | 182189.7 | 0 | 2750095 | 87603 | None | DVG20 | 66 kV Lightening Arrestors.
(0.072 MT per Structure) | No. | 9779.22 | 9779.22 | 6.0 | False | None | None | False | None | False | 58675.32 | 0 | 2750096 | 87603 | None | DVG21 | 11kV Cable Terminating Structure of LV side of 66/11 KV transformer.
(0.072 MT per Structure) | No. | 9779.22 | 9779.22 | 2.0 | False | None | None | False | None | False | 19558.44 | 0 | 2750097 | 87603 | None | DVG22 | BUS BAR FORMATION :Drake ACSR | Mtr | 387.0 | 387.0 | 300.0 | False | None | None | False | None | False | 116100.0 | 0 | 2750098 | 87603 | None | DVG23 | Earth Wire 7/3.15mmsteel with clamp/lugs | Mtr | 88.0 | 88.0 | 50.0 | False | None | None | False | None | False | 4400.0 | 0 | 2750099 | 87603 | None | DVG24 | Post insulator: Solid core polymer Rod Insulator 66 kV class. | No. | 5434.0 | 5434.0 | 3.0 | False | None | None | False | None | False | 16302.0 | 0 | 2750100 | 87603 | None | DVG25 | Disc Insulators and Hardwares
Single tension string using 6 units of each 11kV, 90KN Disc insulator along with Bolted type tension clamp and hardware suitable for Drake ACSR (66kV side) | No | 5984.0 | 5984.0 | 24.0 | False | None | None | False | None | False | 143616.0 | 0 | 2750101 | 87603 | None | DVG26 | Single Suspension string using 6 units of each 11kV, 90KN Disc insulator along with Suspension clamp and hardware suitable for Drake ACSR (66kV side) | No | 5081.0 | 5081.0 | 3.0 | False | None | None | False | None | False | 15243.0 | 0 | 2750102 | 87603 | None | DVG27 | Hardware:
T-clamp suitable for Drake-Drake-Fire wedge connector type | No. | 2305.0 | 2305.0 | 33.0 | False | None | None | False | None | False | 76065.0 | 0 | 2750103 | 87603 | None | DVG28 | T-clamp suitable for Coyote-Drake-Fire wedge connector type | No. | 2186.0 | 2186.0 | 12.0 | False | None | None | False | None | False | 26232.0 | 0 | 2750104 | 87603 | None | DVG29 | Post insulator clamp suitable for Single Drake ACSR and polymer rod insulator | No. | 1010.0 | 1010.0 | 3.0 | False | None | None | False | None | False | 3030.0 | 0 | 2750105 | 87603 | None | DVG30 | AC Distribution Box (Outdoor):
AC Distribution box single front type, 6 terminals, 750x1350x300 mm, 1I/C of 100A, MCCB 20kA+6 O/G MCB 16A+ 1 O/G of 100A, HRC fuse. | Set | 72600.0 | 72600.0 | 1.0 | False | None | None | False | None | False | 72600.0 | 0 | 2750106 | 87603 | None | DVG31 | 11kV UG Cable with required terminations Item No 49 & 50.1
11kV Class, 1X1000 Sq., XLPE, UG Cable | Mtr | 1185.0 | 1185.0 | 120.0 | False | None | None | False | None | False | 142200.0 | 0 | 2750107 | 87603 | None | DVG32 | 11kV Class, heat Shrinkable type cable termination kit suitable for 1X1000 Sq.mm XLPE UG Cable (Outdoor) | Nos. | 4060.0 | 4060.0 | 8.0 | False | None | None | False | None | False | 32480.0 | 0 | 2750108 | 87603 | None | DVG33 | PVC insulated Copper Control Cable with Lugs / Ferrules. : 19 Core 2.5 Sq.mm. Copper Control Cables | Mtr | 525.0 | 525.0 | 1000.0 | False | None | None | False | None | False | 525000.0 | 0 | 2750109 | 87603 | None | DVG34 | PVC insulated Copper Control Cable with Lugs / Ferrules. : 4 Core 6.0 Sq.mm. Copper Control Cables for PTs | Mtr | 247.0 | 247.0 | 600.0 | False | None | None | False | None | False | 148200.0 | 0 | 2750110 | 87603 | None | DVG35 | PVC insulated Copper Control Cable with Lugs / Ferrules. : 4 Core 2.5 Sq.mm. Copper Control Cables | Mtr | 142.0 | 142.0 | 500.0 | False | None | None | False | None | False | 71000.0 | 0 | 2750111 | 87603 | None | DVG36 | PVC insulated Copper Control Cable with Lugs / Ferrules. : 2 Core 6.0 Sq.mm Copper Control Cables | Mtr | 154.0 | 154.0 | 500.0 | False | None | None | False | None | False | 77000.0 | 0 | 2750112 | 87603 | None | DVG37 | PVC insulated Copper Control Cable with Lugs / Ferrules. : 2 Core 2.5 Sq.mm. Copper Control Cables | Mtr | 94.0 | 94.0 | 500.0 | False | None | None | False | None | False | 47000.0 | 0 | 2750113 | 87603 | None | DVG38 | Miscellaneous Items :
Rubber mat of size 1000mm x 2000mm x 12mm size suitable for 1.1kV Class | No | 1900.0 | 1900.0 | 2.0 | False | None | None | False | None | False | 3800.0 | 0 | 2750114 | 87603 | None | DVG39 | Equipment & Earthing name Plate | No | 150.0 | 150.0 | 24.0 | False | None | None | False | None | False | 3600.0 | 0 |
| 1708584944000 | 0 | None | None | Electrical | TB Erection | 660497.55 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2750115 | 87604 | None | DVG01 | CIRCUIT BREAKER : SF-6 circuit breakers with semi pneumatic / pneumatic operated / Spring type operating mechanism, including mounting structure with rigid, bi-metallic terminal connector suitable for Drake ACSR and mounting structure. (UNDER SHUTDOWN CONDITION)
66 kV, 1250 A, 31.5 KA SF6 CB With capacitive trip device.
Line side | No. | 8652.0 | 8652.0 | 1.0 | False | None | None | False | None | False | 8652.0 | 0 | 2750116 | 87604 | None | DVG02 | ISOLATORS : Isolators including marshalling box, terminal connectors suitable for Drake ACSR and solid core cylindrical post insulators.
66 kV, 1250 A, 31.5 KA class double break manually operated isolator with solid core insulators (UNDER SHUTDOWN CONDITION)
Upright mounting type with Earth switch.LPH 4.60 Mtr. | Set | 4293.0 | 4293.0 | 1.0 | False | None | None | False | None | False | 4293.0 | 0 | 2750117 | 87604 | None | DVG03 | ISOLATORS : Isolators including marshalling box, terminal connectors suitable for Drake ACSR and solid core cylindrical post insulators.
66 kV, 1250 A, 31.5 KA class double break manually operated isolator with solid core insulators (UNDER SHUTDOWN CONDITION)
Upright mounting type without Earth switch.LPH 4.60 Mtr. | Set | 4293.0 | 4293.0 | 4.0 | False | None | None | False | None | False | 17172.0 | 0 | 2750118 | 87604 | None | DVG04 | CURRENT TRANSFORMER : Current transformer Single phase, oil filled outdoor type with rigid bimetallic terminal connectors suitable for Drake ACSR.
(UNDER SUTDOWN CONDITION)
66 kV class, 31.5 KA, CT of ratio 400-200 / 1-1-1A for Lines For metering : Accuracy 0.2, Burden 10 VAFor backup protection : Accuracy 5P20. Burden 30 VA For differential /Distance protection PS class | No. | 1505.0 | 1505.0 | 3.0 | False | None | None | False | None | False | 4515.0 | 0 | 2750119 | 87604 | None | DVG05 | SURGE ARRESTOR : (Procelain housing) metal oxide, Gapless type with rigid bimetallic connectors suitable for Drake ACSR.
60 kV, 10 KA, class - II, Normal duty Metal oxide type | No. | 244.33 | 244.33 | 6.0 | False | None | None | False | None | False | 1465.98 | 0 | 2750120 | 87604 | None | DVG06 | Control and Relay Panel- Simplex type 110 DC compatible to SCADA complete.: 66KV Transmission line panel Simplex type | No. | 4191.0 | 4191.0 | 1.0 | False | None | None | False | None | False | 4191.0 | 0 | 2750121 | 87604 | None | DVG07 | Equipments required for Integration of New Bay to Existing SCADA Panel as per KPTCL specification.
Currente cable - Copper core with c/s 7C X 4.0 Sqmm multistrand. | Mtr | 15.0 | 15.0 | 5.0 | False | None | None | False | None | False | 75.0 | 0 | 2750122 | 87604 | None | DVG08 | Voltage cable - Copper core with c/s 4C X 2.5 Sqmm multistrand. | Mtr | 15.0 | 15.0 | 5.0 | False | None | None | False | None | False | 75.0 | 0 | 2750123 | 87604 | None | DVG09 | Signal Cable - Armoured Copper core with c/s 10C X 0.5 Sqmm multistrand. | Mtr | 15.0 | 15.0 | 5.0 | False | None | None | False | None | False | 75.0 | 0 | 2750124 | 87604 | None | DVG10 | Supply of Control cables copper core 10C X 1.5 Sq mm Multistrand, conforming to KPTCL specifications. | Mtr | 15.0 | 15.0 | 5.0 | False | None | None | False | None | False | 75.0 | 0 | 2750125 | 87604 | None | DVG11 | RJ 45 cable for Energy meter integration to DCU (Market rate ) | Mtr | 15.0 | 15.0 | 5.0 | False | None | None | False | None | False | 75.0 | 0 | 2750126 | 87604 | None | DVG12 | STATION STRUCTURES :
66KV side: station structure out of fabricated iron galvanized ( Appr. Unit wt. in MT add 5% for B&N) (UNDER SUTDOWN CONDITION)
Station Towers - ISMB 300x140 structure 12 meter long for column including angle iron cleats etc.,(0.54 MT) | No. | 5723.0 | 5723.0 | 1.14 | False | None | None | False | None | False | 6524.22 | 0 | 2750127 | 87604 | None | DVG13 | Station beams - ISMB 250x125 structure 7.9 meter long for Beam including angle iron cleats etc.,(0.2607 MT) | No. | 5723.0 | 5723.0 | 1.714 | False | None | None | False | None | False | 9809.222 | 0 | 2750128 | 87604 | None | DVG14 | Station towers (Verticals 6T1) (0.956 MT) | No. | 5723.0 | 5723.0 | 2.8665 | False | None | None | False | None | False | 16404.9795 | 0 | 2750129 | 87604 | None | DVG15 | Station beams (6B1) (0.504 MT) | No. | 5723.0 | 5723.0 | 1.008 | False | None | None | False | None | False | 5768.784 | 0 | 2750130 | 87604 | None | DVG16 | MOUNTING STRUCTURES :
(Unit wt. in MT add 5 % for B&N)
(UNDER SUTDOWN CONDITION)
66 kV Isolator Live point height 4600 mm.
(0.76 MT per Structure) | No. | 5723.0 | 5723.0 | 3.8 | False | None | None | False | None | False | 21747.4 | 0 | 2750131 | 87604 | None | DVG17 | 66 kV Current transformer
(0.149 MT per Structure) | No. | 5723.0 | 5723.0 | 1.341 | False | None | None | False | None | False | 7674.543 | 0 | 2750132 | 87604 | None | DVG18 | 66 kV Lightening Arrestors.
(0.072 MT per Structure) | No. | 5723.0 | 5723.0 | 0.432 | False | None | None | False | None | False | 2472.336 | 0 | 2750133 | 87604 | None | DVG19 | 11kV Cable Terminating Structure of LV side of 66/11 KV transformer.
(0.072 MT per Structure) | No. | 5723.0 | 5723.0 | 0.144 | False | None | None | False | None | False | 824.112 | 0 | 2750134 | 87604 | None | DVG20 | Formation of Main/Cross bus with Single Drake for 66kV Side: (UNDER SUTDOWN CONDITION)
(Main Bus all the three phases in segments of using Drake conductor with fixing of insulators, levelling of string conductors to the required height including providing jumps to interconnect different segments of the main bus) | No | 12087.0 | 12087.0 | 3.0 | False | None | None | False | None | False | 36261.0 | 0 | 2750135 | 87604 | None | DVG21 | Post insulator: Solid core polymer Rod Insulator 66 kV class. | No. | 244.0 | 244.0 | 3.0 | False | None | None | False | None | False | 732.0 | 0 | 2750136 | 87604 | None | DVG22 | AC Distribution Box (Outdoor):
AC Distribution box single front type, 6 terminals, 750x1350x300 mm, 1I/C of 100A, MCCB 20kA+6 O/G MCB 16A+ 1 O/G of 100A, HRC fuse. | Set | 2466.0 | 2466.0 | 1.0 | False | None | None | False | None | False | 2466.0 | 0 | 2750137 | 87604 | None | DVG23 | 11kV UG Cable with required terminations Item No 49 & 50.1
11kV Class, 1X1000 Sq., XLPE, UG Cable | Mtr | 72.0 | 72.0 | 120.0 | False | None | None | False | None | False | 8640.0 | 0 | 2750138 | 87604 | None | DVG24 | 11kV Class, heat Shrinkable type cable termination kit suitable for 1X1000 Sq.mm XLPE UG Cable (Outdoor) | Nos. | 3752.0 | 3752.0 | 8.0 | False | None | None | False | None | False | 30016.0 | 0 | 2750139 | 87604 | None | DVG25 | PVC insulated Copper Control Cable with Lugs / Ferrules. : 19 Core 2.5 Sq.mm. Copper Control Cables | Mtr | 15.0 | 15.0 | 1000.0 | False | None | None | False | None | False | 15000.0 | 0 | 2750140 | 87604 | None | DVG26 | PVC insulated Copper Control Cable with Lugs / Ferrules. : 4 Core 6.0 Sq.mm. Copper Control Cables for PTs | Mtr | 15.0 | 15.0 | 600.0 | False | None | None | False | None | False | 9000.0 | 0 | 2750141 | 87604 | None | DVG27 | PVC insulated Copper Control Cable with Lugs / Ferrules. : 4 Core 2.5 Sq.mm. Copper Control Cables | Mtr | 15.0 | 15.0 | 500.0 | False | None | None | False | None | False | 7500.0 | 0 | 2750142 | 87604 | None | DVG28 | PVC insulated Copper Control Cable with Lugs / Ferrules. : 2 Core 6.0 Sq.mm Copper Control Cables | Mtr | 15.0 | 15.0 | 500.0 | False | None | None | False | None | False | 7500.0 | 0 | 2750143 | 87604 | None | DVG29 | PVC insulated Copper Control Cable with Lugs / Ferrules. : 2 Core 2.5 Sq.mm. Copper Control Cables | Mtr | 15.0 | 15.0 | 500.0 | False | None | None | False | None | False | 7500.0 | 0 | 2750144 | 87604 | None | DVG30 | Earth Mat formation :
Grounding of equipments with 50 x 6 mm GI flats and connecting equipments to earth mat or ground pit each point of earthing with all formation of works like bending, twisting, drilling of holes and connecting by welding (inclusive of all T&P and Consumables) to the earthmat/ ground pit/ point of earth connection, all the materials supplied by the contractor. | Rmtr | 335.0 | 335.0 | 243.0 | False | None | None | False | None | False | 81405.0 | 0 | 2750145 | 87604 | None | DVG31 | Grounding of Equipments by providing CI pipe of 100 mm ID, 13mm thickness, 2.75 mtrs long with 2 part clamps out of GI flat 50 x 6 mm continously welded all around the pipe using Cast iron welding electrodes as per the approved drawing including the cost of excavation (All materials to be supplied by the contractor). | Set | 16283.0 | 16283.0 | 6.0 | False | None | None | False | None | False | 97698.0 | 0 | 2750146 | 87604 | None | DVG32 | Supplying and providing 450mm dia and 450mm height 1.5to 2 " thickness RCC Hume pipe collar (non pressure type) for earth pits including Transportion, all lead and lifts, etc. | No | 1499.0 | 1499.0 | 6.0 | False | None | None | False | None | False | 8994.0 | 0 | 2750147 | 87604 | None | DVG33 | Release & Re-erection (UNDER SHUTDOWN CONDITION)
Release & Re-erection of existing 66kV Current Transformers | No | 3010.0 | 3010.0 | 6.0 | False | None | None | False | None | False | 18060.0 | 0 | 2750148 | 87604 | None | DVG34 | Release & Re-erection of existing 66kV Circuit Breaker | No | 17304.0 | 17304.0 | 2.0 | False | None | None | False | None | False | 34608.0 | 0 | 2750149 | 87604 | None | DVG35 | Release & Re-erection of existing 66kV Lighting arrestor | No | 488.66 | 488.66 | 3.0 | False | None | None | False | None | False | 1465.98 | 0 | 2750150 | 87604 | None | DVG36 | Release & Re-erection of existing 66/11kV Power Transformers (Moving of Transformer =37 MT*30 Mtr =1110 MT /m) | No | 160.0 | 160.0 | 1110.0 | False | None | None | False | None | False | 177600.0 | 0 | 2750151 | 87604 | None | DVG37 | Release & Re-erection of 11kV Capacitor Bank | No | 4162.0 | 4162.0 | 1.0 | False | None | None | False | None | False | 4162.0 | 0 |
| 1708584944000 | 0 | None | None | Electrical | TB Civil | 1407499.63 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2750152 | 87605 | None | DVG01 | Earth work excavation by manual means for drains,canals, waste weir,draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter,excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.
In all kinds of soils Depth upto 1.5 m | Cum | 242.0 | 242.0 | 117.2286 | False | None | None | False | None | False | 28369.3212 | 0 | 2750153 | 87605 | None | DVG02 | Earth work excavation by manual means for drains,canals, waste weir,draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter,excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.
In all kinds of soils Depth from 1.5m upto 3.0m | Cum | 242.0 | 242.0 | 10.0869 | False | None | None | False | None | False | 2441.0298 | 0 | 2750154 | 87605 | None | DVG03 | Providing and laying in position M7.5 plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5664.0 | 5664.0 | 7.536 | False | None | None | False | None | False | 42683.904 | 0 | 2750155 | 87605 | None | DVG04 | Providing and laying in position M20 Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) (Raft) | Cum | 6789.99 | 6789.99 | 10.9273 | False | None | None | False | None | False | 74196.257727 | 0 | 2750156 | 87605 | None | DVG05 | Providing and laying in position M20 Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) (Footings) | Cum | 6475.61 | 6475.61 | 38.3786 | False | None | None | False | None | False | 248524.845946 | 0 | 2750157 | 87605 | None | DVG06 | Providing and laying in position M20 Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) (Pedastals) | Cum | 6789.96 | 6789.96 | 68.2855 | False | None | None | False | None | False | 463655.81358 | 0 | 2750158 | 87605 | None | DVG07 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 266.0 | 266.0 | 57.23 | False | None | None | False | None | False | 15223.18 | 0 | 2750159 | 87605 | None | DVG08 | Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work | Cum | 85.0 | 85.0 | 1876.6777 | False | None | None | False | None | False | 159517.6045 | 0 | 2750160 | 87605 | None | DVG09 | Providing Thermo-Mechanically Treated bars of grade Fe-550D or more Steel reinforcement for R.C.C. work ready to use "cut and bend" rebars of approved make from factory/workshop to construction site including placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. | Kg | 79.01 | 79.01 | 863.188 | False | None | None | False | None | False | 68200.48388 | 0 | 2750161 | 87605 | None | DVG10 | Providing and installing at site of work P.V.C. pipes of 10 Kg/m2: 160mm including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges,handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. | Rmtr | 969.1 | 969.1 | 70.0 | False | None | None | False | None | False | 67837.0 | 0 | 2750162 | 87605 | None | DVG11 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.. | No | 5454.0 | 5454.0 | 6.0 | False | None | None | False | None | False | 32724.0 | 0 | 2750163 | 87605 | None | DVG12 | Removing and Re spreading of Existing jelly | Sqm | 55.0 | 55.0 | 210.0 | False | None | None | False | None | False | 11550.0 | 0 | 2750164 | 87605 | None | DVG13 | Jelly Spreading : Providing and spreading of 20/25mm jelly of thickness 100mm | Sqm | 177.3 | 177.3 | 850.0 | False | None | None | False | None | False | 150705.0 | 0 | 2750165 | 87605 | None | DVG14 | M-Sand for filling over ug Cable | Cum | 1476.0 | 1476.0 | 1.2 | False | None | None | False | None | False | 1771.2 | 0 | 2750166 | 87605 | None | DVG15 | Bricks for filling over ug Cable | No | 8.0 | 8.0 | 300.0 | False | None | None | False | None | False | 2400.0 | 0 | 2750167 | 87605 | None | DVG16 | Cable tray of 300 mm width
(suitable for cable duct of D type) | Rmtr | 754.0 | 754.0 | 50.0 | False | None | None | False | None | False | 37700.0 | 0 |
| 1708584944000 | 0 | None | None | Electrical | TTB T&C | 103503.99 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2750168 | 87606 | None | DVG01 | CIRCUIT BREAKER : SF-6 circuit breakers with semi pneumatic / pneumatic operated / Spring type operating mechanism, including mounting structure with rigid, bi-metallic terminal connector suitable for Drake ACSR and mounting structure. (UNDER SHUTDOWN CONDITION)
66 kV, 1250 A, 31.5 KA SF6 CB With capacitive trip device.
Line side | No. | 42300.0 | 42300.0 | 1.0 | False | None | None | False | None | False | 42300.0 | 0 | 2750169 | 87606 | None | DVG02 | ISOLATORS : Isolators including marshalling box, terminal connectors suitable for Drake ACSR and solid core cylindrical post insulators.
66 kV, 1250 A, 31.5 KA class double break manually operated isolator with solid core insulators (UNDER SHUTDOWN CONDITION)
Upright mounting type with Earth switch.LPH 4.60 Mtr. | Set | 826.0 | 826.0 | 1.0 | False | None | None | False | None | False | 826.0 | 0 | 2750170 | 87606 | None | DVG03 | ISOLATORS : Isolators including marshalling box, terminal connectors suitable for Drake ACSR and solid core cylindrical post insulators.
66 kV, 1250 A, 31.5 KA class double break manually operated isolator with solid core insulators (UNDER SHUTDOWN CONDITION)
Upright mounting type without Earth switch.LPH 4.60 Mtr. | Set | 826.0 | 826.0 | 4.0 | False | None | None | False | None | False | 3304.0 | 0 | 2750171 | 87606 | None | DVG04 | CURRENT TRANSFORMER : Current transformer Single phase, oil filled outdoor type with rigid bimetallic terminal connectors suitable for Drake ACSR.
(UNDER SUTDOWN CONDITION)
66 kV class, 31.5 KA, CT of ratio 400-200 / 1-1-1A for Lines For metering : Accuracy 0.2, Burden 10 VAFor backup protection : Accuracy 5P20. Burden 30 VA For differential /Distance protection PS class | No. | 4700.33 | 4700.33 | 3.0 | False | None | None | False | None | False | 14100.99 | 0 | 2750172 | 87606 | None | DVG05 | Control and Relay Panel- Simplex type 110 DC compatible to SCADA complete.: 66KV Transmission line panel Simplex type | No. | 42973.0 | 42973.0 | 1.0 | False | None | None | False | None | False | 42973.0 | 0 |
|
|
---|