createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1708492149128
version5
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyRESERVED
invitingStrategyTextReserved
taxTypeINCLUSIVE_TAX
tenderFee1580.00
emd76000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose04-03-2024 16:00:00
tenderQueryClose02-03-2024 11:00:00
technicalBidOpen06-03-2024 11:00:00
publishedDate21-02-2024 11:31:06
publishedByPostRDPR_EE_DIV_CKD
publishedByUserKPE13024 - BASAVARAJ CHANNAMALLAPPA KATTI
bidValidityPeriod90
noOfCalls2
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnTrue
percentageRateTypeTextNone
contactPersonS M KOLI JE
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08338272131
mobileNumber8197629009
tenderSupplierListNone
tenderSchedule
createdTs1708492149131
version17
createdDateNone
modifiedDateNone
tenderNumberRDPR/2023-24/BD/WORK_INDENT1139/CALL-2
titleCONSTRUCTION OF 3 ROOMS AT GOVT P U COLLAGE AT BALOBAL VILLAGE IN GOKAK TALUKA (2022-23 VIVEK YOJANE)
descriptionCONSTRUCTION OF 3 ROOMS AT GOVT P U COLLAGE AT BALOBAL VILLAGE IN GOKAK TALUKA (2022-23 VIVEK YOJANE)
categoryWORKS
categoryTextWorks
ecv6314556.13
deptNameRural Development and Panchayat Raj Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location828
locationNameRDPR Division Office Chikkodi
provisionalAmount7515000.0
groupOverheadTotal0.0
fileNumberAEE/PRE/GKK/2023-24/21
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17084921490001NoneNoneBuildingsBUILDING5492357.52
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
272615786320Nonecode01Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering & leveling the ground for all works other than foundation & depth in all kinds of soil not exceeding 300mm as per drawing and technical specifcations, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work and as per directions of theEngineer-in-Charge.Sqm73.573.5334.79FalseNoneNoneFalseNoneFalse24607.0650
272615886320Nonecode02Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifcations,including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work and as per directions of theEngineer-in-Charge.Cum240.45240.45191.76FalseNoneNoneFalseNoneFalse46108.6920
272615986320Nonecode03Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifcations. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates and as per directions of theEngineer-in-Charge.Cum5831.75831.726.43FalseNoneNoneFalseNoneFalse154131.8310
272616086320Nonecode04Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticizers laid in fnished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifcations.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates and as per directions of theEngineer-in-Charge.Cum6418.446418.4416.52FalseNoneNoneFalseNoneFalse106032.62880
272616186320Nonecode05Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticizers laid in fnished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifcations.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates and as per directions of theEngineer-in-Charge.Cum10103.110103.15.33FalseNoneNoneFalseNoneFalse53849.5230
272616286320Nonecode06Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates and as per directions of theEngineer-in-Charge.Cum10509.410509.412.97FalseNoneNoneFalseNoneFalse136306.9180
272616386320Nonecode07Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates and as per directions of theEngineer-in-Charge.Cum6676.566676.5626.92FalseNoneNoneFalseNoneFalse179732.99520
272616486320Nonecode08Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates and as per directions of theEngineer-in-Charge.Cum6491.16491.156.54FalseNoneNoneFalseNoneFalse367006.7940
272616586320Nonecode09Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand :12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 complete as per specifcations and as per directions of Engineer-in-charge.Cum4987.54987.579.52FalseNoneNoneFalseNoneFalse396606.00
272616686320Nonecode10Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 complete as per specifcations and as per directions of Engineer-in-charge.Cum5619.65619.634.5FalseNoneNoneFalseNoneFalse193876.20
272616786320Nonecode11Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.and as per directions of Engineer-in-charge.Cum214.2214.2227.46FalseNoneNoneFalseNoneFalse48721.9320
272616886320Nonecode12Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifcations.and as per directions of Engineer-in-charge.Cum6014.46014.437.92FalseNoneNoneFalseNoneFalse228066.0480
272616986320Nonecode13Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifcations and as per directions of Engineer-in-charge.Cum90393.090393.00.833FalseNoneNoneFalseNoneFalse75297.3690
272617086320Nonecode14Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work and as per directions of Engineer-in-charge.Cum8022.08022.076.29FalseNoneNoneFalseNoneFalse611998.380
272617186320Nonecode15Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifcations.and as per directions of Engineer-in-charge.Kgs96.696.69807.1FalseNoneNoneFalseNoneFalse947365.860
272617286320Nonecode16Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fne sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifcations and as per directions of Engineer-in-chargeSqm260.4260.4688.11FalseNoneNoneFalseNoneFalse179183.8440
272617386320Nonecode17Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) fnished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fne sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifcations and as per directions of Engineer-in-charge.Sqm322.35322.35475.45FalseNoneNoneFalseNoneFalse153261.30750
272617486320Nonecode18Providing and fixing M S grills of required pattern in frames of windows with M S flats square or round bars etc including priming coat with approved steel primer all complete fixed to openings/wooden frames with rawl plugs screw etcKgs150.15150.15800.1FalseNoneNoneFalseNoneFalse120135.0150
272617586320Nonecode19Providing and fixing of 3 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL 9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer)and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame.The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mmx 58mm. Coextruded Glazing bead for fixing of glass shall be of size20mm x 24 mm. Windows shall be provided with 6mm plain float glass,standard hardware& Multi point locking system with touch lock. Wall thickness of frame and sash shall be of 2mm 2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T and P's shall not be made)Sqm7602.07602.031.62FalseNoneNoneFalseNoneFalse240375.240
272617686320Nonecode20Providing and fxing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifcations. and as per directions of theEngineer-in-Charge.Sqm5074.05074.017.22FalseNoneNoneFalseNoneFalse87374.280
272617786320Nonecode21Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifcations and as per directions of Engineer-in-chargeSqm105.0105.0688.11FalseNoneNoneFalseNoneFalse72251.550
272617886320Nonecode22Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifcations and as per directions of Engineer-in-charge .Cum208.0208.0475.45FalseNoneNoneFalseNoneFalse98893.60
272617986320Nonecode23Providing and laying polished Glazed Vitrified tiles in floor with different sizes (Thickness to be specifed by the manufacturer), with water absorption less than 0.08% and conforming to IS : 15622, of approved brand and manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS :15477 in average 6 mm thickness, including grouting of joints (Payment for grouting of joints tobe made separatelySqm1324.051324.05210.21FalseNoneNoneFalseNoneFalse278328.55050
272618086320Nonecode24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specifed and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent and as per directions of Engineer-in-charge.Sqm1261.01261.0105.2FalseNoneNoneFalseNoneFalse132657.20
272618186320Nonecode25Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifcations and as per directions of Engineer-in-charge.Sqm1088.851088.8515.7FalseNoneNoneFalseNoneFalse17094.9450
272618286320Nonecode26Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifcations and as per directions of Engineer-in-charge.Sqm105.0105.038.75FalseNoneNoneFalseNoneFalse4068.750
272618386320Nonecode27Providing and fixing 304 - grade stainless steel hand rails of 14-gauge pipes for Ramps or Staircase are made out of stainless steel hallow pipes, using 50mm dia for verticals @1.60 mtr c/c are fixed to the ramps or steps by drilling with bolts and 100mm dia MS base plates 10mm gauge for fixing of Vertical pipes 4 - Nos anchor bolts & 40mm dia pipes are fixed horizontally for 2-rows top, one pipes are fixed with vertical pipes another one are fixed with elbows and 25mm dia pipes are fixed horizontally for 2-rows below top measure @ equal intervals including cutting, welding, bending wherever necessary with suitable caps @ tops, bottoms & corners finishing with mat / shining etc., complete including cost and conveyance of all materials, labour for all items of work, HOM of equipment with all lead and lift, loading and unloading, transportation charges and all other incidental charges etc., complete as per specification and directions of the Engineer-in-charge of the work.Kgs500.0500.0903.63FalseNoneNoneFalseNoneFalse451815.00
272618486320Nonecode28Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark as per directions of Engineer-in-charge.Nos888.0888.03.0FalseNoneNoneFalseNoneFalse2664.00
272618586320Nonecode29Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:. 110mm dia 6kg/sqcm and as per directions of Engineer-in-charge.Mtr271.0271.0100.0FalseNoneNoneFalseNoneFalse27100.00
272618686320Nonecode30Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as .and as per directions of Engineer-in-charge.Sqm3621.453621.458.25FalseNoneNoneFalseNoneFalse29876.96250
272618786320Nonecode31Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directionsof Engineer-in-charge.cm3.153.154500.0FalseNoneNoneFalseNoneFalse14175.00
272618886320Nonecode32Providing and fxing precoated galvanised iron profle sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard flm of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fxed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. and as per directions of Engineer-in-charge.Sqm556.0556.024.09FalseNoneNoneFalseNoneFalse13394.040
17084921490000NoneNoneBuildingsELECTRIFICATION295535.0
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
272618986321Nonecode01Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5 mm2 (Phase & Neutral) & 1x1.0 mm 2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Medium point above 3m upto 6m from tapping point to out let via switchRmtr386.0386.0100.0FalseNoneNoneFalseNoneFalse38600.00
272619086321Nonecode02do-Long point above 6m upto 10m from tapping point to out let via switchRmtr567.0567.050.0FalseNoneNoneFalseNoneFalse28350.00
272619186321Nonecode03Supplying and fixing of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment 48" Sweep 5 Star (1200 mmNo3111.03111.06.0FalseNoneNoneFalseNoneFalse18666.00
272619286321Nonecode04Supplying and fixing of LED light fitting 1 x 4' - 20/22 W. PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical conditionNo1226.01226.015.0FalseNoneNoneFalseNoneFalse18390.00
272619386321Nonecode05Supply and Fixing of LED Street light luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with LED Streetlight 40W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned LED Streetlight 90 WNo7966.07966.04.0FalseNoneNoneFalseNoneFalse31864.00
272619486321Nonecode06Supplying and fixing superior quality 8 Module modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC boxNo302.0302.020.0FalseNoneNoneFalseNoneFalse6040.00
272619586321Nonecode07Supplying and fixing surface/flush mounting unbreakable PVC 8 Way modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.Each250.0250.020.0FalseNoneNoneFalseNoneFalse5000.00
272619686321Nonecode08Supplying and fixing superior quality 12 Module modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC boxEach363.0363.010.0FalseNoneNoneFalseNoneFalse3630.00
272619786321Nonecode09Supplying and fixing surface/flush mounting unbreakable PVC 12 Way modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.Each325.0325.08.0FalseNoneNoneFalseNoneFalse2600.00
272619886321Nonecode10Supplying and fixing superior quality 12 Module modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC boxEach175.0175.08.0FalseNoneNoneFalseNoneFalse1400.00
272619986321Nonecode11Supplying and fixing surface/flush mounting unbreakable PVC 4 Way modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.Each138.0138.08.0FalseNoneNoneFalseNoneFalse1104.00
272620086321Nonecode12Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6A One Way SwitchEach88.088.025.0FalseNoneNoneFalseNoneFalse2200.00
272620186321Nonecode13Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6A Three Way socketEach162.0162.028.0FalseNoneNoneFalseNoneFalse4536.00
272620286321Nonecode14Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 16A One Way SwitchEach249.0249.010.0FalseNoneNoneFalseNoneFalse2490.00
272620386321Nonecode15Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6/16A Universal SocketEach249.0249.010.0FalseNoneNoneFalseNoneFalse2490.00
272620486321Nonecode16Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 32A DP SwitchEach375.0375.04.0FalseNoneNoneFalseNoneFalse1500.00
272620586321Nonecode17Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 Supplying And Fixing "S" Hook made out of 14 mm dia M.S. Rod.Each79.079.010.0FalseNoneNoneFalseNoneFalse790.00
272620686321Nonecode18Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 Stepped Fan Regulator Two ModuleEach313.0313.010.0FalseNoneNoneFalseNoneFalse3130.00
272620786321Nonecode19Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A DPEach1103.01103.09.0FalseNoneNoneFalseNoneFalse9927.00
272620886321Nonecode20Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A SPEach523.0523.010.0FalseNoneNoneFalseNoneFalse5230.00
272620986321Nonecode21Supplying and Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clA and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.Each3255.03255.01.0FalseNoneNoneFalseNoneFalse3255.00
272621086321Nonecode22Supplying and fixing of 25 mm PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm, .... etc. as requiredRmtr28.028.0550.0FalseNoneNoneFalseNoneFalse15400.00
272621186321Nonecode23Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.1.5 mm2Each26.026.01380.0FalseNoneNoneFalseNoneFalse35880.00
272621286321Nonecode24Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 2.5 mm2Each40.040.0520.0FalseNoneNoneFalseNoneFalse20800.00
272621386321Nonecode25Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 4 mm2Each59.059.0180.0FalseNoneNoneFalseNoneFalse10620.00
272621486321Nonecode26Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.32 AEach200.0200.02.0FalseNoneNoneFalseNoneFalse400.00
272621586321Nonecode27Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.4 Way SP & NEach1368.01368.01.0FalseNoneNoneFalseNoneFalse1368.00
272621686321Nonecode28Fabricating, supplying and erection of ms long Glass Reinforced Plastics (GRP) Lighting Pole or Reinforced Thermosetting Plastic Pole (FRP) Conical- Embedded Type including Double Arm Brackets having made out of Polyester Resin with Glass Fibre by CNC Machines wherein Programmable Logic Control (PLC) is used in a close loop control circuit to control machine movements. This system allows for placement of right amount of fibreglass at the right place & orientation, Non filled resin system, Available upto 2 m to 12m, having Pole thickness 6 9 mm , Tolerance in Length+ 40 mm . Tolerance in Thickness +/-0.5 mm .Glass Content More than 60%m, Die Electric Strength 7.3 kV/ mm . Hence Pole does not require earthing, Specific Gravity 1.3 TO 1.95 kg/cm2, Tensile Strength 200 50 MPA, Flexural Strength 250 50 MPA, Compressive Strength15050 MPA, Impact Resistance 250 50 KJ/M2, Water Absorption 0.5, Surface Colour Shade Polyurethane Paint of Shade Aluminium, Charcoal or as per Client Requirement, Accessories (Optional) Junction Box Side Arm/Tenon Mount Bracket, Hardware MS Zinc Passivated, Wind Load Our Pole will withstand high wind load upto 50 MS with maximum deflection of 15%. TECHNICAL DETAILS FOUNDATION Specification: Standard Shaft Burial Depth will be as under. Also available as per Client Requirement 900 mm upto 5.5 m Pole for 1000 Series, 1200 mm upto 7 m Pole for 1000 Series 900 mm upto 5.5 m Pole for 3000 Series, 1200 mm upto 7.5 m Pole for 3000 Series 1500 3 m Top 70 mm and Bottom 94 mm dia 5 mm thicknessEach17325.017325.01.0FalseNoneNoneFalseNoneFalse17325.00
272621786321Nonecode29Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws.8" x 6" x 1.5"Each76.076.08.0FalseNoneNoneFalseNoneFalse608.00
272621886321Nonecode30Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws 10" x 8" x 1.5Each97.097.010.0FalseNoneNoneFalseNoneFalse970.00
272621986321Nonecode31Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws 12" x 12" x 2"Each162.0162.06.0FalseNoneNoneFalseNoneFalse972.00
17084921490000NoneNoneBuildingsMATERIAL SUPPLY526663.61
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
272622086322Nonecode01Providing i3 11th gen with GB ram/512ssd/window 11-sl/msoffice ( as per gem govt rate ) Product ID:51116877-4927149087Nos45500.045500.02.0FalseNoneNoneFalseNoneFalse91000.00
272622186322Nonecode02ZERONICS floor mounted horizantal profile projector 600 milimeter 20x and 25x 50x 100x 12 months ID:5116877-9401031581)Nos10000.010000.03.0FalseNoneNoneFalseNoneFalse30000.00
272622286322Nonecode034FTx6FT map type projector screen 84" ( as per gem govt rate ) Product ID:5116877-24317223718Nos2200.02200.03.0FalseNoneNoneFalseNoneFalse6600.00
272622386322Nonecode04Staff chairs office chair ( as per gem govt rate ) Product ID:5116877-99820008887Nos2200.02200.03.0FalseNoneNoneFalseNoneFalse6600.00
272622486322Nonecode05WOODEN table ( as per gem govt rate ) Product ID:5116877-74712178689Nos2487.872487.873.0FalseNoneNoneFalseNoneFalse7463.610
272622586322Nonecode06Desk of class roomNos5500.05500.070.0FalseNoneNoneFalseNoneFalse385000.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17084921490000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17084921490000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17084921490000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17084921490000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of KarnatakaNone
17084921490000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17084921490000NoneNoneELIGIBILITYDepartment Registration DetailsNone
17084921490000NoneNoneELIGIBILITYTotal value of civl engineering works executed and payments received in the last five years (year-wise)None
17084921490000NoneNoneELIGIBILITYList of existing commitments and ongoing workNone
17084921490000NoneNoneELIGIBILITYList of works for which tenders already submittedNone
17084921490000NoneNoneELIGIBILITYBanker DetailsNone
17084921490000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptableNone
17084921490000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of KarnatakaNone
17084921490000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17084921490000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of KarnatakaNone
17084921490000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of KarnatakaNone
17084921490000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17084921490000NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of of e-Procurement portal due to internet connectivity issues and technical glitches at bidders end.None
17084921490000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17084921490000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidder.None
17084921490000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17084921490000NoneNoneELIGIBILITYFor Details Refer Tender Notification And Conditions In The Bid Documents.None
17084921490000NoneNoneELIGIBILITYAcceptence / Cancellation of the works are reserved by under signed without any reasons for the same.None
17084921490000NoneNoneELIGIBILITYExecutive Engineer PRED Chikodi has authority to accept or reject any tender without assigning reason.None
17084921490000NoneNoneELIGIBILITYCorrigendum / modifications / correction, if any, will be published in the website only.None
17084921490000NoneNoneELIGIBILITYTo qualify for award of this contract, each tenderer should give all details and documents as per Technical and Financial bid attached to this tender.None
17084921490000NoneNoneELIGIBILITYIncomplete / conditional tenders will not be accepted.None
17084921490000NoneNoneELIGIBILITYTenderer must submit his present accurate postal address and phone / cell phone numberNone
17084921490000NoneNoneELIGIBILITYThe tender may be cancelled at any stage without assigning any reasonNone
17084921490000NoneNoneELIGIBILITYAny objection regarding the tender must be submitted directly to Executive Engineer , not in inward.None
17084921490000NoneNoneELIGIBILITYFor interpretations of clauses, conditions, spelling mistakes, etc., decision of Executive Engineer, PRED, Chikodi is final.None
17084921490000NoneNoneELIGIBILITYSuccessful bidder submitting bids below the amount put to tender will be regularized to submit the difference amount in the form of FDR/TDR/DD/Pledge on the name of EE PRED Belagavi within 20 days from the date of receiving the letter of acceptance. additional security paid for unbalanced tenders Failing which EMD will be forfeited and further action will be taken as per G O No FD PCL 2008 Bangalore Dated 14/10/2008.None
17084921490000NoneNoneELIGIBILITYWork shall be executed as per KTPP Act & Service Tender Conditions.None
17084924490000NoneNoneELIGIBILITYOnly SC Contractor can apply for this work and they Should Submit Cast Certificat Issued by Compentative Tahshildar, Refer Govt Notification No:FD/387/exp-12/2014 dt: - 08-2017 for SC WorksNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneTender must have physical workdone as prescribed in bid document KW-3 ie Executed in any one year the following minimum quantities of work Embankment Excavation 421.24 Cum, RCC/PCC 145.46 Cum, BBM/SS Masonary 91.21 Cum, Steel 7.84 Tonne.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Tender must have physical workdone as prescribed in bid document KW-3 ie Executed in any one year the following minimum quantities
NoneNoneNoneNoneContractor should upload PWD Valid Registration copy & PRED Enrollment Copy abiding to latest publication of KPWD Departmental Code.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNonePAN CARDCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- PAN
NoneNoneNoneNoneas per Govt Circular no GO-FD/AE 263/EXP12-2022 dt 11.05.2022, this clause for owning key equipment for works costing upto Rs 3.00 Crores is exempted.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- MACHINERY
NoneNoneNoneNoneAdequate Staff pattern should beavailable with tendererCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Adequate Staff pattern should beavailable with tenderer
NoneNoneNoneNoneTenderer must have assessed available tender capacity as per formula in section 3.6 of KW-3 DocumentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- BID CAPACITY
NoneNoneNoneNoneThe tenderer should possess valid GST registrationCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
NoneNoneNoneNoneProfit & loss account from CA for last five years.Tenderer mast have Tenderer must have achieved in at least two financial years an average Annual financial Turn over (in all classes of civil construction works only) (i.e. Rs.63.00 lakhs) (2018-19 to 2022-23)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Profit & loss account from CA for last five years.Tenderer mast have Tenderer must have achieved in at least two financial years an average
NoneNoneNoneNoneAs per Govt Circular no GO-FD/AE 263/EXP12-2022 dt 11.05.2022, this clause for owning key equipment for works costing upto Rs 3.00 Crores is exempted.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- As per Govt Circular no GO-FD/AE 263/EXP12-2022 dt 11.05.2022, this clause for owning key equipment for works costing upto Rs 3.00 Crores is exempted
NoneNoneNoneNoneMandating satisfactory completion as a prime contractor for at least one similar work to an extent of 25 % such as Construction of Building of Value not less than Rs.16.00 LakhsCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- workdone
NoneNoneNoneNoneThe Tenderer should submit the line of credit from Banker of a nationalized Bank / Scheduled Bank / liquid assets amounting to (Rs.19.00 lakhs)of tender price nationalized Bank / Scheduled BankCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- line of credit from Banker of a nationalized Bank / Scheduled Bank / liquid assets amountingto (Rs.19.00 lakhs)of tender price loc
NoneNoneNoneNoneOTHERSOthersAccurate Postal address and phone / Mobile Number
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Accurate Postal address and phone / Mobile Number
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Reserved Category CertificateFalseTechnical Bid
Contractor should upload PWD Valid Registration copy & PRED Enrollment Copy abiding to latest publication of KPWD Departmental Code.TrueTechnical Bid
PAN Card copyTrueTechnical Bid
The Tenderer must submit ongoing work commitmentTrueTechnical Bid
Adequate Staff pattern should beavailable with tendererTrueTechnical Bid
Accurate Postal address and phone / Mobile NumberTrueTechnical Bid
Tenderer must have assessed available tender capacity as per formula in section 3.6 of KW-3DocumentTrueTechnical Bid
The tenderer should possess valid GST registrationTrueTechnical Bid
Annual Turnover Certificate Last five year 63.00 lakhsTrueTechnical Bid
Embankment/Excavation 421.24 Cum RCC/PCC 145.46 Cum Brick/stone masonry 91.21 cum steel 7.84 MTTrueTechnical Bid
As per Govt Circular no GO-FD/AE 263/EXP12-2022 dt 11.05.2022, this clause for owning key equipment for works costing upto Rs 3.00 Crores is exempted.TrueTechnical Bid
Caste Certificate from Respetive Tahshildar Officer SC CATEGORYTrueTechnical Bid
domicial certificateTrueTechnical Bid
Mandating satisfactory completion as a prime contractor for at least one similar work to an extent of 25 per such as Construction of Building of Value not less than Rs.16.00 LakhsTrueTechnical Bid
Line of credit from Banker of a nationalized Bank or Scheduled Bank or liquid assets amounting to 30 per tender price amount 19.00 lakhsTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone