tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1708243424000 | 0 | None | None | Buildings | TICKET COUNTER, ENTRY PLAZA TOILETS, INFORMATION CENTRE, FOOD COURT, ADMINISTRATIVE BLOCK RESEARCH CENTRE, MUSEUM, AMPHITHEATRE ETC AT KITTUR CHENNAMMA ZOO Ground floor | 12889319.49 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2686341 | 84179 | None | 1.12 | 1.12 Earth work in surface excavation by mechanical means for lowering &leveling the ground for all works other than foundation in all kinds ofsoils & upto depth not exceeding 300mm as per drawing and technicalspecifications, including setting out, shoring, strutting,barricading,caution lights, removal of stumps and other deleterious matter includingdressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radiusof 50 m and lift upto 1.5 m including cost of labour, tools, usage ofmachinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth
| Cum | 95.0 | 95.0 | 160.39 | False | None | None | False | None | False | 15237.05 | 0 | 2686342 | 84179 | None | 1.14.1 | 1.14.1 Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m
| Cum | 102.0 | 102.0 | 634.52 | False | None | None | False | None | False | 64721.04 | 0 | 2686343 | 84179 | None | 4.1 | 4.1 Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.
| Sqm | 118.0 | 118.0 | 306.48 | False | None | None | False | None | False | 36164.64 | 0 | 2686344 | 84179 | None | 2.1.3 | 2.1.3 Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates
| Cum | 5989.0 | 5989.0 | 106.2 | False | None | None | False | None | False | 636031.8 | 0 | 2686345 | 84179 | None | 2.2.3 | 2.2.3 Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 6336.0 | 6336.0 | 86.95 | False | None | None | False | None | False | 550915.2 | 0 | 2686346 | 84179 | None | addendum | FORMWORK FOR FOOTING: Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 506.88 | 506.88 | 86.95 | False | None | None | False | None | False | 44073.216 | 0 | 2686347 | 84179 | None | 2.4.3 | 2.4.3 Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded co2.4.3 Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement & formwork to be paid separately)
arse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement & formwork to be paid separately)
| Cum | 6336.0 | 6336.0 | 23.5 | False | None | None | False | None | False | 148896.0 | 0 | 2686348 | 84179 | None | Addendum 1 | FORMWORK FOR PLINTH BEAM @ 50 % of the rate of above concrete item
Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement to be paid separately) | Cum | 3168.0 | 3168.0 | 23.5 | False | None | None | False | None | False | 74448.0 | 0 | 2686349 | 84179 | None | 2.5.2 | 2.5.2 Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 6843.0 | 6843.0 | 12.83 | False | None | None | False | None | False | 87795.69 | 0 | 2686350 | 84179 | None | Addendum 1 | FORMWORK FOR COLUMN : Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 4790.1 | 4790.1 | 12.83 | False | None | None | False | None | False | 61456.983 | 0 | 2686351 | 84179 | None | 2.5.2 | 2.5.2 Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 6843.0 | 6843.0 | 24.96 | False | None | None | False | None | False | 170801.28 | 0 | 2686352 | 84179 | None | Addendum 1 | FORMWORK FOR LINTEL, SLAB BEAM :Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement to be paid separately)
| Cum | 4790.1 | 4790.1 | 24.96 | False | None | None | False | None | False | 119560.896 | 0 | 2686353 | 84179 | None | 2.5.2 | 2.5.2 Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 6843.0 | 6843.0 | 57.86 | False | None | None | False | None | False | 395935.98 | 0 | 2686354 | 84179 | None | Addendum 1 | FORMWORK FOR SLAB : Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 3421.5 | 3421.5 | 57.86 | False | None | None | False | None | False | 197967.99 | 0 | 2686355 | 84179 | None | 2.5.1 | 2.5.1 Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 6630.0 | 6630.0 | 9.2 | False | None | None | False | None | False | 60996.0 | 0 | 2686356 | 84179 | None | 2.5.2 | FORMWORK FOR CHAJJA @ 45 % of the rate of above concrete item
Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 2983.5 | 2983.5 | 9.2 | False | None | None | False | None | False | 27448.2 | 0 | 2686357 | 84179 | None | 2.5.2 | 2.5.2 Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 6843.0 | 6843.0 | 13.11 | False | None | None | False | None | False | 89711.73 | 0 | 2686358 | 84179 | None | Addendum 1 | FORMWORK FOR STAIRCASE: Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 3421.5 | 3421.5 | 13.11 | False | None | None | False | None | False | 44855.865 | 0 | 2686359 | 84179 | None | 5.4 | 5.4 Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)
| Cum | 6389.0 | 6389.0 | 47.95 | False | None | None | False | None | False | 306352.55 | 0 | 2686360 | 84179 | None | 1.8 | 1.8 Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.
| Cum | 474.0 | 474.0 | 752.59 | False | None | None | False | None | False | 356727.66 | 0 | 2686361 | 84179 | None | 2.11 | 2.11 Steel Fabrication Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings | Tonne | 89457.0 | 89457.0 | 26.86 | False | None | None | False | None | False | 2402815.02 | 0 | 2686362 | 84179 | None | 2.1.4 | 2.1.4 Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 6217.0 | 6217.0 | 0.973 | False | None | None | False | None | False | 6049.141 | 0 | 2686363 | 84179 | None | 6.2 | 6.2 Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.
| Cum | 7978.0 | 7978.0 | 145.35 | False | None | None | False | None | False | 1159602.3 | 0 | 2686364 | 84179 | None | 11.34A | 11.34A Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding
| Kgs | 168.0 | 168.0 | 1491.0 | False | None | None | False | None | False | 250488.0 | 0 | 2686365 | 84179 | None | 12.84 | 12.84 Providing & fixing of 2 track 2 panel sliding windows made out of multi chambered UPVC(Matching to RAL 9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm by 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size 1219mm by 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made (Volume 2 Page No 110 Item No. 12.84) | Sqm | 5023.0 | 5023.0 | 71.0 | False | None | None | False | None | False | 356633.0 | 0 | 2686366 | 84179 | None | 8.3.1 | 8.3.1 Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 354.0 | 354.0 | 88.75 | False | None | None | False | None | False | 31417.5 | 0 | 2686367 | 84179 | None | 8.8 | 8.8 Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 371.0 | 371.0 | 943.3 | False | None | None | False | None | False | 349964.3 | 0 | 2686368 | 84179 | None | 8.1.1 | 8.1.1 Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 255.0 | 255.0 | 1267.5 | False | None | None | False | None | False | 323212.5 | 0 | 2686369 | 84179 | None | 8.51 | 8.51 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.
| Sqm | 100.0 | 100.0 | 1522.44 | False | None | None | False | None | False | 152244.0 | 0 | 2686370 | 84179 | None | 9.30 | 9.30 Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.
| Sqm | 5328.0 | 5328.0 | 287.57 | False | None | None | False | None | False | 1532172.96 | 0 | 2686371 | 84179 | None | 9.21.2 | 9.21.2 Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm
| Sqm | 1238.0 | 1238.0 | 191.58 | False | None | None | False | None | False | 237176.04 | 0 | 2686372 | 84179 | None | 8.63 | 8.63 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: One coats on old work as per specifications and as per directions of Engineer in charge.
| Sqm | 82.0 | 82.0 | 1522.4482 | False | None | None | False | None | False | 124840.7524 | 0 | 2686373 | 84179 | None | 12.13.2 | 12.13.2 Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.
| Cum | 99600.0 | 99600.0 | 0.451 | False | None | None | False | None | False | 44919.6 | 0 | 2686374 | 84179 | None | 12.57.4 | 12.57.4. Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side Teak.
| Sqm | 4532.0 | 4532.0 | 20.25 | False | None | None | False | None | False | 91773.0 | 0 | 2686375 | 84179 | None | 8.29 | 8.29 Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 283.0 | 283.0 | 1032.05 | False | None | None | False | None | False | 292070.15 | 0 | 2686376 | 84179 | None | 8.45.2 | 8.45.2 Varnishing with varnish of approved brand and manufacture :Two coats glue sizing with spar varnish or an under coat of flatting varnish to give an even shade and produce a smooth dry and mat surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign mattersand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 173.0 | 173.0 | 50.63 | False | None | None | False | None | False | 8758.99 | 0 | 2686377 | 84179 | None | 8.34.3 | 8.34.3 Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 50.0 | 50.0 | 71.0 | False | None | None | False | None | False | 3550.0 | 0 | 2686378 | 84179 | None | 8.40 | 8.40 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 115.0 | 115.0 | 71.0 | False | None | None | False | None | False | 8165.0 | 0 | 2686379 | 84179 | None | 12.51 | 12.51 Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.
| Nos | 1016.0 | 1016.0 | 8.0 | False | None | None | False | None | False | 8128.0 | 0 | 2686380 | 84179 | None | 11.28 | 11.28 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,
| Kgs | 565.0 | 565.0 | 271.408 | False | None | None | False | None | False | 153345.52 | 0 | 2686381 | 84179 | None | 9.6.1 | 9.6.1 Providing and laying Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand)
| Sqm | 1269.0 | 1269.0 | 16.53 | False | None | None | False | None | False | 20976.57 | 0 | 2686382 | 84179 | None | 12.69.1 | 12.69.1 Providing and fixing ISI marked oxidised M.S. single acting spring hinges
with necessary screws etc.150mm
| Nos | 274.0 | 274.0 | 48.0 | False | None | None | False | None | False | 13152.0 | 0 | 2686383 | 84179 | None | P.No A25 I.No 444 | Providing and fixing Hold fasts for doors etc complete ( Material Components P.No -A25 I.No 444 )
| Nos | 50.0 | 50.0 | 48.0 | False | None | None | False | None | False | 2400.0 | 0 | 2686384 | 84179 | None | 12.73.1 | 12.73.1 Providing and fixing ISI marked oxidised M.S. handles conforming to
IS:4992 with necessary screws etc. complete :125mm | Nos | 44.0 | 44.0 | 16.0 | False | None | None | False | None | False | 704.0 | 0 | 2686385 | 84179 | None | P.No A20 I.No 274 | Providing and fixing Door Locks approved make and quality including cost and conveyence of all maerials with all lead and lift. etc complete ( Material Components P.No - A20 I.No 274 )
| Nos | 348.0 | 348.0 | 8.0 | False | None | None | False | None | False | 2784.0 | 0 | 2686386 | 84179 | None | 12.63 | 12.63 Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete
| Nos | 130.0 | 130.0 | 16.0 | False | None | None | False | None | False | 2080.0 | 0 | 2686387 | 84179 | None | A28 I No 548 | Providing and fixing Screws approved Nails and screws of sizes for structural glazing /ACP Cladding ( Material Components P.No - A28 I.No 548 )
| Kgs | 67.0 | 67.0 | 5.0 | False | None | None | False | None | False | 335.0 | 0 | 2686388 | 84179 | None | 6.15 | 6.15 Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.
| Sqm | 1033.0 | 1033.0 | 208.03 | False | None | None | False | None | False | 214894.99 | 0 | 2686389 | 84179 | None | 9.11 | 9.11 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.
| Sqm | 889.0 | 889.0 | 11.85 | False | None | None | False | None | False | 10534.65 | 0 | 2686390 | 84179 | None | 9.39 | 9.39 Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.
| Sqm | 1449.0 | 1449.0 | 75.97 | False | None | None | False | None | False | 110080.53 | 0 | 2686391 | 84179 | None | 12.83.2 | 12.83.2 Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance1mm), with wall thickness 2.0 mm (0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 by19 mm and 1mm (0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineer- in-charge
| m | 239.0 | 239.0 | 31.2 | False | None | None | False | None | False | 7456.8 | 0 | 2686392 | 84179 | None | 12.53 | 12.53 Providing & fixing 30mm thick factory made rigid foam Panelled Door Shutters made from M.S. tube of 19 gauge thickness, size 19x19mm for stiles and 15x15mm for top & bottom rails, covered with heat moulded PVC C channel of 5mm thick sheet & 30 x 50mm wide to form stiles & 5mm thick & 75mm wide PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet fitted in the M.S. Frame, Sealed to the stiles & rails with 5x30mm PVC sheet beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm Aluminium hinges.
| Sqm | 1588.0 | 1588.0 | 10.08 | False | None | None | False | None | False | 16007.04 | 0 | 2686393 | 84179 | None | 11.37.3 | 11.37.3 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 8 mm thickness (weight not less than 20 kg/ m²) including cost of materials, labour, usage charges of machinery complete as per specifications.
| Sqm | 1305.0 | 1305.0 | 24.18 | False | None | None | False | None | False | 31554.9 | 0 | 2686394 | 84179 | None | 12.49 | 12.49 Providing and fixing in position fully glazed shutters for ventilators side hung or central pivoted with Honne wood stiles and rails of 30mm thick 50mm wide and central divider of 30mm. wide, 3mm thick reeded glass fixed with wooden beading of size 10mm wide flushed to the thickness of the frame including cost of materials, labour charges, usage charges complete as per specifications. (excluding cost of fixtures)
| Sqm | 6523.0 | 6523.0 | 32.4 | False | None | None | False | None | False | 211345.2 | 0 | 2686395 | 84179 | None | 8.10 | 8.10 Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 211.0 | 211.0 | 330.91 | False | None | None | False | None | False | 69822.01 | 0 | 2686396 | 84179 | None | 2.3.2 | 2.3.2. Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 6480.0 | 6480.0 | 16.43 | False | None | None | False | None | False | 106466.4 | 0 | 2686397 | 84179 | None | Addendum | FORMWORK FOR RC WALL : Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 648.0 | 648.0 | 16.43 | False | None | None | False | None | False | 10646.64 | 0 | 2686398 | 84179 | None | 11.16.2 | 11.16.2 Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
| Kgs | 147.0 | 147.0 | 829.65 | False | None | None | False | None | False | 121958.55 | 0 | 2686399 | 84179 | None | 10.20 | 10.20 Providing and fixing of clay tiles for cladding tiles of size 230x75x10mm thick on 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) & jointed with Adhesive/cement slurry over rough plaster surface excluding cost of rough plastered surface and the surface is painted with red apex paint and black apex paint into the groves. The work includes cost of all materials, labour charges for all items of work, usage charges for equipment, etc., complete as per specification.
| Sqm | 1902.0 | 1902.0 | 118.17 | False | None | None | False | None | False | 224759.34 | 0 | 2686400 | 84179 | None | 7.25.1 | 7.25.1. Providing and fixing plain multipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete. 6 mm thick Cement fiber board as per IS: 14862
| Sqm | 635.0 | 635.0 | 114.83 | False | None | None | False | None | False | 72917.05 | 0 | 2686401 | 84179 | None | 10 cudm, vol - 2 , Page no - A-40 | 942 Superior class teak wood such as Dandeli planks ( 10 cudm, vol - 2 , Page no - A-40).
| Cum | 1100.0 | 1100.0 | 20.35 | False | None | None | False | None | False | 22385.0 | 0 | 2686402 | 84179 | None | data rate | Supply and fixing of Vox Infratop false ceiling manufactured in Europe, panel sizes of 340mmx 2700mm,durable and resistant to moisture, water and borer-fungus-termite attack. Panels to be installed with GI/ Aluminium sections of suitable gauge & size according to site conditions. Panels SV 08/07 & 09 with suitable trims SV 15 with dimensions 40x19x22x12x3050 (all in mm) for edge profiles and SV 18 with dimensions 67x3050 mm with T head of 42mm for Connecting profiles. Panels must be maintenance free, rust proof and are 100% Water proof. Advised especially for Soffit areas, under the roof installation. 10 years warranty for colour & finish of the panels and the profiles from VOX.Supply and fixing of Vox trims manufactured in Europe with trims SV 15 with dimensions 40x19x22x12x3050 (all in mm) for edge profiles and to be installed with GI / Aluminium sections of suitable gauge & size according to site conditions.1.Supply and fixing of Vox trims manufactured in Europe with trims SV 18 with dimensions 67x3050 mm with T head of 42mm for Connecting profiles and to be installed with GI / Aluminium sections of suitable gauge & size according to site conditions.Providing and fixing of frame work made of special sections power pressed from MS sheet and galvanized in accordance with zinc coating of grade 350 as per IS: 277 and consisting of angle cleat of size 25 mm wide x 1.6 mm thick with flanges of 22 mm and 37 mm at 1200 mm center to center one flange fixed to the ceiling with dash fastener 12.5 mm dia x 40 mm long with 6 mm dia bolts to the angle hangers of 25 x 25 x 0.55 m of massivad lanath and athan and of analo tapered flanges of 26 mm each having clips of 10.5 mm at 450 mm center to center shall be fixed in a direction perpendicular to GI channel with connecting clips made out of 2.64 mm dia x 230 mm long GI wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, The perimeter of ceiling shall be fixed to wall/ partition with the help of raw plugs at 450 mm center to center with 25 mm long drive-all screws @230 mm interval including jointing and fixing to a flush finish of tapered and square edges of the gypsum board with recommended filler, paper tapes, finisher and making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Employer / Architect. But excluding cost of painting. etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work (Wooden Colour as per approved by department)
| Sqm | 2400.0 | 2400.0 | 33.21 | False | None | None | False | None | False | 79704.0 | 0 | 2686403 | 84179 | None | 1.23 | 1.23 Providing and Filling in foundation with granite / trap broken metal 100mm. and down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications.
| Cum | 2682.0 | 2682.0 | 44.264 | False | None | None | False | None | False | 118716.048 | 0 | 2686404 | 84179 | None | 2.5.2 | 2.5.2 Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 6843.0 | 6843.0 | 35.64 | False | None | None | False | None | False | 243884.52 | 0 | 2686405 | 84179 | None | addendum | FORMWORK FOR LINTEL SLAB BEAM Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement to be paid separately) | Cum | 4105.8 | 4105.8 | 35.64 | False | None | None | False | None | False | 146330.712 | 0 |
| 1708243424000 | 1 | None | None | Buildings | First Floor | 5691141.37 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2686406 | 84180 | None | 2.5.2 | 2.5.2 Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 6911.43 | 6911.43 | 11.84 | False | None | None | False | None | False | 81831.3312 | 0 | 2686407 | 84180 | None | Addendum | FORMWORK FOR COLUMN FROM Ground Floor slab to First Floor Slab: Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 4838.0 | 4838.0 | 11.84 | False | None | None | False | None | False | 57281.92 | 0 | 2686408 | 84180 | None | 2.5.2 | 2.5.2 Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 6911.43 | 6911.43 | 18.0 | False | None | None | False | None | False | 124405.74 | 0 | 2686409 | 84180 | None | addendum | FORMWORK FOR LINTEL,FIRST FLOOR SLAB BEAM :Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 4146.86 | 4146.86 | 18.0 | False | None | None | False | None | False | 74643.48 | 0 | 2686410 | 84180 | None | 2.5.2 | 2.5.2 Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 6911.43 | 6911.43 | 69.03 | False | None | None | False | None | False | 477096.0129 | 0 | 2686411 | 84180 | None | Addendum | FORMWORK FOR FIRST FLOOR SLAB: Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregate
| Cum | 3455.72 | 3455.72 | 69.03 | False | None | None | False | None | False | 238548.3516 | 0 | 2686412 | 84180 | None | 2.5.1 | 2.5.1 Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 6696.3 | 6696.3 | 0.41 | False | None | None | False | None | False | 2745.483 | 0 | 2686413 | 84180 | None | addendum | FORMWORK FOR CHAJJA: Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregate
| Cum | 3013.34 | 3013.34 | 0.41 | False | None | None | False | None | False | 1235.4694 | 0 | 2686414 | 84180 | None | 2.11 | 2.11 Steel Fabrication Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings
| Tonne | 90351.57 | 90351.57 | 15.16 | False | None | None | False | None | False | 1369729.8012 | 0 | 2686415 | 84180 | None | 2.1.4 | 2.1.4 Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 6279.17 | 6279.17 | 0.5 | False | None | None | False | None | False | 3139.585 | 0 | 2686416 | 84180 | None | 6.2 | 6.2 Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.
| Cum | 8057.78 | 8057.78 | 89.19 | False | None | None | False | None | False | 718673.3982 | 0 | 2686417 | 84180 | None | 11.34A | 11.34A Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding
| Kgs | 169.68 | 169.68 | 462.0 | False | None | None | False | None | False | 78392.16 | 0 | 2686418 | 84180 | None | 12.84 | 12.84 Providing & fixing of 2track 2panel sliding windows made out of multi chambered UPVC(Matching to RAL9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets color having isolated drainage and reinforced with Galvanized Iron profile throughout the window frame. The outer frame having an overall size of 44mm width 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size 1219mm 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made (Volume 2 Page No 110 Item No. 12.84) | Sqm | 5073.23 | 5073.23 | 22.0 | False | None | None | False | None | False | 111611.06 | 0 | 2686419 | 84180 | None | 8.8 | 8.8 Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 374.71 | 374.71 | 506.71 | False | None | None | False | None | False | 189869.3041 | 0 | 2686420 | 84180 | None | 8.1.1 | 8.1.1 Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 257.55 | 257.55 | 183.71 | False | None | None | False | None | False | 47314.5105 | 0 | 2686421 | 84180 | None | 8.51 | 8.51 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.
| Sqm | 101.0 | 101.0 | 648.28 | False | None | None | False | None | False | 65476.28 | 0 | 2686422 | 84180 | None | 9.30 | 9.30 Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.
| Sqm | 5381.28 | 5381.28 | 36.16 | False | None | None | False | None | False | 194587.0848 | 0 | 2686423 | 84180 | None | 9.21.2 | 9.21.2 Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm
| Sqm | 1250.38 | 1250.38 | 313.53 | False | None | None | False | None | False | 392031.6414 | 0 | 2686424 | 84180 | None | 8.63 | 8.63 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: One coats on old work as per specifications and as per directions of Engineer in charge.
| Sqm | 82.82 | 82.82 | 648.28 | False | None | None | False | None | False | 53690.5496 | 0 | 2686425 | 84180 | None | 12.13.2 | 12.13.2 Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.
| Cum | 100596.0 | 100596.0 | 0.122 | False | None | None | False | None | False | 12272.712 | 0 | 2686426 | 84180 | None | 12.57.4 | 12.57.4. Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side Teak.
| Sqm | 4577.32 | 4577.32 | 7.5 | False | None | None | False | None | False | 34329.9 | 0 | 2686427 | 84180 | None | 8.29 | 8.29 Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 285.83 | 285.83 | 506.71 | False | None | None | False | None | False | 144832.9193 | 0 | 2686428 | 84180 | None | 8.45.2 | 8.45.2 Varnishing with varnish of approved brand and manufacture :Two coats glue sizing with spar varnish or an under coat of flatting varnish to give an even shade and produce a smooth dry and mat surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign mattersand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 174.73 | 174.73 | 19.5 | False | None | None | False | None | False | 3407.235 | 0 | 2686429 | 84180 | None | 8.34.3 | 8.34.3 Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 50.5 | 50.5 | 22.0 | False | None | None | False | None | False | 1111.0 | 0 | 2686430 | 84180 | None | 8.40 | 8.40 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 116.15 | 116.15 | 22.0 | False | None | None | False | None | False | 2555.3 | 0 | 2686431 | 84180 | None | 12.51 | 12.51 Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.
| Nos | 1026.16 | 1026.16 | 2.0 | False | None | None | False | None | False | 2052.32 | 0 | 2686432 | 84180 | None | 12.69.1 | 12.69.1 Providing and fixing ISI marked oxidised M.S. single acting spring hinges
with necessary screws etc.125mm"
| Nos | 274.0 | 274.0 | 12.0 | False | None | None | False | None | False | 3288.0 | 0 | 2686433 | 84180 | None | P.No -A25 I.No 444 | Providing and fixing Hold fasts M.S. for doors etc complete ( Material Components P.No -A25 I.No 444 )
| Nos | 50.0 | 50.0 | 12.0 | False | None | None | False | None | False | 600.0 | 0 | 2686434 | 84180 | None | 12.73.1 | 12.73.1 Providing and fixing ISI marked oxidised M.S. handles conforming to
IS:4992 with necessary screws etc. complete :125mm"
| Nos | 44.0 | 44.0 | 4.0 | False | None | None | False | None | False | 176.0 | 0 | 2686435 | 84180 | None | P.No A20 | Providing and fixing Door Locks approved make and quality including cost and conveyence of all maerials with all lead and lift. etc complete ( Material Components P.No -A20 I.No 274 )
| Nos | 348.0 | 348.0 | 2.0 | False | None | None | False | None | False | 696.0 | 0 | 2686436 | 84180 | None | 12.63 | 12.63 Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete
| Nos | 130.0 | 130.0 | 4.0 | False | None | None | False | None | False | 520.0 | 0 | 2686437 | 84180 | None | P.No - A28 I.No 548) | Providing and fixing Screws approved make SS Screws of sizes for structural glazing /ACP Cladding ( Material Components P.No - A28 I.No 548)
| Kgs | 67.0 | 67.0 | 3.0 | False | None | None | False | None | False | 201.0 | 0 | 2686438 | 84180 | None | 8.10 | 8.10 Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 212.0 | 212.0 | 464.57 | False | None | None | False | None | False | 98488.84 | 0 | 2686439 | 84180 | None | KSFIC.DWD - 097 | KSFIC.DWD - 097 Teak Wood Dias Reiling :- Made out of 3"x3" turning legs, affixed together in 2"x1" patti at top & bottom maintaining a distance of 12" between every leg. Further finished with 3"x1.5" pattis on top and bottom, such that the flat surface is seen above. To be fixed on site with necessary screws, embeded in the floor. (Per Running Meter )
| m | 9102.0 | 9102.0 | 78.72 | False | None | None | False | None | False | 716509.44 | 0 | 2686440 | 84180 | None | 7.25.1 | 7.25.1. Providing and fixing plain multipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete. 6 mm thick Cement fiber board as per IS: 14862
| Sqm | 638.0 | 638.0 | 446.57 | False | None | None | False | None | False | 284911.66 | 0 | 2686441 | 84180 | None | 10.20 | 10.20 Providing and fixing of clay tiles for cladding tiles of size 230x75x10mm thick on 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) & jointed with Adhesive/cement slurry over rough plaster surface excluding cost of rough plastered surface and the surface is painted with red apex paint and black apex paint into the groves. The work includes cost of all materials, labour charges for all items of work, usage charges for equipment, etc., complete as per specification.
| Sqm | 1906.0 | 1906.0 | 53.98 | False | None | None | False | None | False | 102885.88 | 0 |
| 1708243424000 | 0 | None | None | Buildings | Electrical | 2753302.06 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2686442 | 84181 | None | 1.1.1 | Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy
gauge saddles at an interval of 700mm using NF screws.19/20 mm dia 2 mm thick
| m | 69.0 | 69.0 | 600.0 | False | None | None | False | None | False | 41400.0 | 0 | 2686443 | 84181 | None | 1.1.2 | Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy
gauge saddles at an interval of 700mm using NF screws.25 mm dia 2 mm thick
| m | 81.0 | 81.0 | 400.0 | False | None | None | False | None | False | 32400.0 | 0 | 2686444 | 84181 | None | 1.1.3 | Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.32 mm dia 2.5 mm thick
| m | 106.0 | 106.0 | 100.0 | False | None | None | False | None | False | 10600.0 | 0 | 2686445 | 84181 | None | 1.2.1 | Supplying heavy gauge PVC conduit pipe . mm dia.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire
wherever necessary19/20 mm dia 2 mm thick
| m | 66.0 | 66.0 | 300.0 | False | None | None | False | None | False | 19800.0 | 0 | 2686446 | 84181 | None | 1.2.2 | Supplying heavy gauge PVC conduit pipe . mm dia.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire
wherever necessary 25 mm dia 2 mm thick
| m | 78.0 | 78.0 | 600.0 | False | None | None | False | None | False | 46800.0 | 0 | 2686447 | 84181 | None | 1.2.3 | Supplying heavy gauge PVC conduit pipe . mm dia.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire
wherever necessary 32 mm dia 2.5 mm thick
| m | 103.0 | 103.0 | 100.0 | False | None | None | False | None | False | 10300.0 | 0 | 2686448 | 84181 | None | 1.3.1 | Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish
wire run throughout the conduit wherever necessary.19/20 mm dia 2 mm thick
| m | 68.0 | 68.0 | 120.0 | False | None | None | False | None | False | 8160.0 | 0 | 2686449 | 84181 | None | 1.3.2 | Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish
wire run throughout the conduit wherever necessary.25 mm dia 2 mm thick
| m | 79.0 | 79.0 | 210.0 | False | None | None | False | None | False | 16590.0 | 0 | 2686450 | 84181 | None | 1.3.3 | Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish
wire run throughout the conduit wherever necessary.32 mm dia 2.5 mm thick
| m | 99.0 | 99.0 | 60.0 | False | None | None | False | None | False | 5940.0 | 0 | 2686451 | 84181 | None | 1.13 | Supplying And Fixing Metal Fan Box with Round Hook.
| No | 117.0 | 117.0 | 42.0 | False | None | None | False | None | False | 4914.0 | 0 | 2686452 | 84181 | None | 1.14.4 | Supply and laying of underfloor (concealed) raceways manufactured from 1.5 mm thick cover and base (including partitions for multi- compartment raceways), zero spangle pre-galvanized sheet steel with 275 GSM ( 36.67 microns) coating mass, cover and base MIG welded together. the length of raceways shall be 2.5 meters per length with single accessories acting as duct connector including fastening clamps and vertical access boxes and with all required connected accessories complete and load bearing capacity in line with EN 50085-2-2. 100 x 38 x 2500mm, 2 compartments
| m | 1066.0 | 1066.0 | 100.0 | False | None | None | False | None | False | 106600.0 | 0 | 2686453 | 84181 | None | 1.15.1 | Supply and laying of under floor junction boxes shall be of three-piece construction Base box, frame and load plate. Base box shall be robust in its construction manufactured from 1.5 mm thick zero spangle pre-galvanized sheet steel with 275 GSM ( 36.67 microns) coating mass. The load plate and frame thicknesses shall be 3 mm and 2 mm respectively to provide adequate load bearing capacity of 5 kN with deflection not greater than 6mm while loading and permanent deflection not exceeding 3 mm as per EN 50085-2-2. The trap and frame shall be Epoxy coated to protect from corrosion. The junction boxes shall be 10 mm or 20 mm recess to accommodate floor covering suitable for Tile/Carpet/marble / granite/ according to site conditions. The junction box has height of 60mm up to finished floor level. The base of junction boxes should have pre-punched sealing arrangements on all four sides to accept either 25 mm or 38 mm of metal raceways. For (50-100x38mm) duct.Dimensions:172 172 60mm. 10 mm
Recess
| No | 1736.0 | 1736.0 | 10.0 | False | None | None | False | None | False | 17360.0 | 0 | 2686454 | 84181 | None | 2.2.1 | Supplying and wiring adopting loop system in existing PVC Conduit
/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box
| Point | 269.0 | 269.0 | 80.0 | False | None | None | False | None | False | 21520.0 | 0 | 2686455 | 84181 | None | 2.2.2 | Supplying and wiring adopting loop system in existing PVC Conduit
/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Medium point above 3Mtr upto 6Mtr from tapping point to out let via
switch box
| Point | 379.0 | 379.0 | 180.0 | False | None | None | False | None | False | 68220.0 | 0 | 2686456 | 84181 | None | 2.2.3 | Supplying and wiring adopting loop system in existing PVC Conduit
/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Long point above 6Mtr upto 10Mtr from tapping point to out let via
switch box
| Point | 555.0 | 555.0 | 160.0 | False | None | None | False | None | False | 88800.0 | 0 | 2686457 | 84181 | None | 2.2.4 | Supplying and wiring adopting loop system in existing PVC Conduit
/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Two outlet in a row, above 3Mtr upto 6Mtr from tapping point to out
let via switches
| Point | 677.0 | 677.0 | 30.0 | False | None | None | False | None | False | 20310.0 | 0 | 2686458 | 84181 | None | 2.2.5 | Supplying and wiring adopting loop system in existing PVC Conduit
/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Three outlet in a row, above 6Mts upto 10Mtr from tapping point to
out let via switches box
| Point | 989.0 | 989.0 | 10.0 | False | None | None | False | None | False | 9890.0 | 0 | 2686459 | 84181 | None | 2.3.1 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-
694:2010 1 mm2
| m | 19.0 | 19.0 | 900.0 | False | None | None | False | None | False | 17100.0 | 0 | 2686460 | 84181 | None | 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-
694:2010 1.5 mm2
| m | 26.0 | 26.0 | 600.0 | False | None | None | False | None | False | 15600.0 | 0 | 2686461 | 84181 | None | 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-
694:2010 2.5 mm2"
| m | 42.0 | 42.0 | 2800.0 | False | None | None | False | None | False | 117600.0 | 0 | 2686462 | 84181 | None | 2.3.4 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-
694:2010 4 mm2"
| m | 63.0 | 63.0 | 2400.0 | False | None | None | False | None | False | 151200.0 | 0 | 2686463 | 84181 | None | 2.3.5 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-
694:2010 6 mm2
| m | 92.0 | 92.0 | 1200.0 | False | None | None | False | None | False | 110400.0 | 0 | 2686464 | 84181 | None | 2.6.2 | Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990.3C x 4 mm2
| m | 168.0 | 168.0 | 450.0 | False | None | None | False | None | False | 75600.0 | 0 | 2686465 | 84181 | None | 2.5.16 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 4C x 4 mm2
| m | 225.0 | 225.0 | 600.0 | False | None | None | False | None | False | 135000.0 | 0 | 2686466 | 84181 | None | 2.5.23 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 4C x 6 mm2
| m | 328.0 | 328.0 | 800.0 | False | None | None | False | None | False | 262400.0 | 0 | 2686467 | 84181 | None | 3.4.1 | SWITCHES, SOCKETS & ACCESSORIES Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall1-2 Way | Each | 138.0 | 138.0 | 10.0 | False | None | None | False | None | False | 1380.0 | 0 | 2686468 | 84181 | None | 3.4.2 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3 Way
| Each | 159.0 | 159.0 | 30.0 | False | None | None | False | None | False | 4770.0 | 0 | 2686469 | 84181 | None | 3.4.3 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5 Way
| Each | 177.0 | 177.0 | 2.0 | False | None | None | False | None | False | 354.0 | 0 | 2686470 | 84181 | None | 3.4.4 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6 Way
| Each | 220.0 | 220.0 | 10.0 | False | None | None | False | None | False | 2200.0 | 0 | 2686471 | 84181 | None | 3.4.5 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way
| Each | 261.0 | 261.0 | 10.0 | False | None | None | False | None | False | 2610.0 | 0 | 2686472 | 84181 | None | 3.4.6 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12 Way
| Each | 319.0 | 319.0 | 4.0 | False | None | None | False | None | False | 1276.0 | 0 | 2686473 | 84181 | None | 3.4.7 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 16 Way
| Each | 363.0 | 363.0 | 6.0 | False | None | None | False | None | False | 2178.0 | 0 | 2686474 | 84181 | None | 3.4.8 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 18 Way
| Each | 405.0 | 405.0 | 2.0 | False | None | None | False | None | False | 810.0 | 0 | 2686475 | 84181 | None | 3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing
metal/PVC box. 1 to 2 Module
| Each | 137.0 | 137.0 | 10.0 | False | None | None | False | None | False | 1370.0 | 0 | 2686476 | 84181 | None | 3.5.2 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing
metal/PVC box. 3 Module"
| Each | 161.0 | 161.0 | 30.0 | False | None | None | False | None | False | 4830.0 | 0 | 2686477 | 84181 | None | 3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing
metal/PVC box. 4 Module
| Each | 175.0 | 175.0 | 2.0 | False | None | None | False | None | False | 350.0 | 0 | 2686478 | 84181 | None | 3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing
metal/PVC box. 6 Module
| Each | 234.0 | 234.0 | 10.0 | False | None | None | False | None | False | 2340.0 | 0 | 2686479 | 84181 | None | 3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing
metal/PVC box. 8 Module
| Each | 284.0 | 284.0 | 10.0 | False | None | None | False | None | False | 2840.0 | 0 | 2686480 | 84181 | None | 3.5.6 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing
metal/PVC box. 10-12 Module
| Each | 344.0 | 344.0 | 4.0 | False | None | None | False | None | False | 1376.0 | 0 | 2686481 | 84181 | None | 3.5.7 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing
metal/PVC box. 16 Module
| Each | 397.0 | 397.0 | 6.0 | False | None | None | False | None | False | 2382.0 | 0 | 2686482 | 84181 | None | 3.5.8 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing
metal/PVC box. 18 Module
| Each | 457.0 | 457.0 | 2.0 | False | None | None | False | None | False | 914.0 | 0 | 2686483 | 84181 | None | 3.6.1 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch
| Each | 102.0 | 102.0 | 160.0 | False | None | None | False | None | False | 16320.0 | 0 | 2686484 | 84181 | None | 3.6.2 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Two Way Switch
| Each | 166.0 | 166.0 | 10.0 | False | None | None | False | None | False | 1660.0 | 0 | 2686485 | 84181 | None | 3.6.3 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Three Way socket
| Each | 171.0 | 171.0 | 40.0 | False | None | None | False | None | False | 6840.0 | 0 | 2686486 | 84181 | None | 3.6.4 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two Module
| Each | 357.0 | 357.0 | 42.0 | False | None | None | False | None | False | 14994.0 | 0 | 2686487 | 84181 | None | 3.6.7 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16A One Way Switch
| Each | 180.0 | 180.0 | 26.0 | False | None | None | False | None | False | 4680.0 | 0 | 2686488 | 84181 | None | 3.6.8 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Bell Push
| Each | 177.0 | 177.0 | 10.0 | False | None | None | False | None | False | 1770.0 | 0 | 2686489 | 84181 | None | 3.6.9 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32A DP Switch
| Each | 326.0 | 326.0 | 10.0 | False | None | None | False | None | False | 3260.0 | 0 | 2686490 | 84181 | None | 3.6.10 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16A Universal Socket
| Each | 236.0 | 236.0 | 32.0 | False | None | None | False | None | False | 7552.0 | 0 | 2686491 | 84181 | None | 3.6.11 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TV/Telephone Socket
| Each | 156.0 | 156.0 | 30.0 | False | None | None | False | None | False | 4680.0 | 0 | 2686492 | 84181 | None | 3.6.12 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. RJ45/I.O Outlet Cat-6
| Each | 337.0 | 337.0 | 10.0 | False | None | None | False | None | False | 3370.0 | 0 | 2686493 | 84181 | None | 3.8 | Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screws.
| Sq CM | 0.41 | 0.41 | 1000.0 | False | None | None | False | None | False | 410.0 | 0 | 2686494 | 84181 | None | 5.2.1 | Supplying fully automatic star-delta starter unit push button type with suitable wires, 3 contactors, one adjustable thermal timer mounted on a common base plate held in steel enclosure for use on 400/440 V 3 phase and wired after fixing to the existing wooden board for motor. upto 12.5 HP
| Each | 7455.0 | 7455.0 | 2.0 | False | None | None | False | None | False | 14910.0 | 0 | 2686495 | 84181 | None | 5.3 | Supplying and fixing single phase preventer using necessary wires over an existing panel board suitable for motor upto 20 HP capacities.
| Each | 904.02 | 904.02 | 3.0 | False | None | None | False | None | False | 2712.06 | 0 | 2686496 | 84181 | None | 5.4.1 | Fixing a shunt capacitor of . kVAR capacity with necessary clamps, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor. upto 5 kVAR
| Each | 154.0 | 154.0 | 3.0 | False | None | None | False | None | False | 462.0 | 0 | 2686497 | 84181 | None | 5.4.1 | Fixing a shunt capacitor of . kVAR capacity with necessary clamps, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor. upto 5 kVAR
| Each | 154.0 | 154.0 | 3.0 | False | None | None | False | None | False | 462.0 | 0 | 2686498 | 84181 | None | 5.5.1 | Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour. 32A
| Each | 1701.0 | 1701.0 | 3.0 | False | None | None | False | None | False | 5103.0 | 0 | 2686499 | 84181 | None | 5.6.4 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs
screws. 12"" x 12"" x 2
| Each | 181.0 | 181.0 | 3.0 | False | None | None | False | None | False | 543.0 | 0 | 2686500 | 84181 | None | 5.7.3 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 63 A
| Each | 401.0 | 401.0 | 3.0 | False | None | None | False | None | False | 1203.0 | 0 | 2686501 | 84181 | None | 5.8.1 | Supplying of Switch disconnector fuse unit (TPN) HRC type (but without HRC fuses). With AC-23A duty and as per IS- 13947. 63 A
| Each | 2312.0 | 2312.0 | 3.0 | False | None | None | False | None | False | 6936.0 | 0 | 2686502 | 84181 | None | 5.12.5 | Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution) 630 A
| Each | 21785.0 | 21785.0 | 4.0 | False | None | None | False | None | False | 87140.0 | 0 | 2686503 | 84181 | None | 5.14.1 | Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 22/25 A
| Each | 2210.0 | 2210.0 | 2.0 | False | None | None | False | None | False | 4420.0 | 0 | 2686504 | 84181 | None | 5.15.13 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR Pole 250 A 25 kA
| Each | 21391.0 | 21391.0 | 2.0 | False | None | None | False | None | False | 42782.0 | 0 | 2686505 | 84181 | None | 5.17.1 | Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2.4 Way
| Each | 10329.0 | 10329.0 | 2.0 | False | None | None | False | None | False | 20658.0 | 0 | 2686506 | 84181 | None | 5.17.2 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC
60898. 6-32 A SP
| Each | 415.0 | 415.0 | 20.0 | False | None | None | False | None | False | 8300.0 | 0 | 2686507 | 84181 | None | 5.18.4 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC
60898. 6-32 A DP
| Each | 739.0 | 739.0 | 10.0 | False | None | None | False | None | False | 7390.0 | 0 | 2686508 | 84181 | None | 5.18.7 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC
60898. 6-32 A TPN
| Each | 1717.0 | 1717.0 | 5.0 | False | None | None | False | None | False | 8585.0 | 0 | 2686509 | 84181 | None | 5.18.9 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC
60898. 50-63 A TPN
| Each | 3088.0 | 3088.0 | 2.0 | False | None | None | False | None | False | 6176.0 | 0 | 2686510 | 84181 | None | 5.19.8 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG
MS enclosure. II - Double Door 8 Way SP & N"
| Each | 1854.0 | 1854.0 | 1.0 | False | None | None | False | None | False | 1854.0 | 0 | 2686511 | 84181 | None | 5.22 | Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board.
| Each | 452.0 | 452.0 | 1.0 | False | None | None | False | None | False | 452.0 | 0 | 2686512 | 84181 | None | 5.25 | Supplying, fixing and wiring 0 to 100 A Direct Reading AC analog type Ammeter
| Each | 524.0 | 524.0 | 1.0 | False | None | None | False | None | False | 524.0 | 0 | 2686513 | 84181 | None | 5.27 | Supplying, fixing and wiring rotary selector switch suitable for Ammeter
| Each | 200.0 | 200.0 | 1.0 | False | None | None | False | None | False | 200.0 | 0 | 2686514 | 84181 | None | 5.28 | Supplying, fixing and wiring rotary selector switch suitable for Voltmeter
| Each | 160.0 | 160.0 | 1.0 | False | None | None | False | None | False | 160.0 | 0 | 2686515 | 84181 | None | 5.29 | Supplying, fixing and wiring 3 Phase Digital Ammeter / Voltmeter
| Each | 1425.0 | 1425.0 | 1.0 | False | None | None | False | None | False | 1425.0 | 0 | 2686516 | 84181 | None | 5.33 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required withcommunication Port and Class 0.5s accuracy
| Each | 9315.0 | 9315.0 | 1.0 | False | None | None | False | None | False | 9315.0 | 0 | 2686517 | 84181 | None | 5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.
| Each | 515.0 | 515.0 | 3.0 | False | None | None | False | None | False | 1545.0 | 0 | 2686518 | 84181 | None | 5.39 | Supplying, fixing and wiring Automatic Power Factor controller circuit unit fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three phase LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect/ disconnect banks, with automatic recognition or with standard programs
| Each | 21640.0 | 21640.0 | 1.0 | False | None | None | False | None | False | 21640.0 | 0 | 2686519 | 84181 | None | 5.40.1 | Supplying . A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS
specification with necessary bolts, nuts and washers etc., complete 100 A 4 x 30 x 6 mm Aluminium Strips
| m | 2465.0 | 2465.0 | 3.0 | False | None | None | False | None | False | 7395.0 | 0 | 2686520 | 84181 | None | 5.40.2 | Supplying . A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS
specification with necessary bolts, nuts and washers etc., complete 250 A 4 x 30 x 10 mm Aluminium Strips
| m | 3435.0 | 3435.0 | 2.0 | False | None | None | False | None | False | 6870.0 | 0 | 2686521 | 84181 | None | 5.41.2 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron. and M.S. Flat.with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 50 x 50 x 6 mm
| m | 395.0 | 395.0 | 20.0 | False | None | None | False | None | False | 7900.0 | 0 | 2686522 | 84181 | None | 5.42.2 | Fabricating supplying and mounting MS box made out SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 16 SWG
| Sq CM | 0.43 | 0.43 | 96000.0 | False | None | None | False | None | False | 41280.0 | 0 | 2686523 | 84181 | None | 5.56 | Supply and fixing of Surge Protection devices (SPD)of type-2 at the power source to the sensitive Electronic and Electrical Equipment. Detail Specification is as follow:
- In Conformance with standards IEC 61643-11/2011 T2 and EN 61643-11type 2.
- For protection against indirect lightining surge and switching surge.
- Inbuilt health indicator.
- Imax (8/20s): 65/40/15/8kA
- Maximum Operating Voltage [Uc]: 340V
- Level of Protection , Up: 1.0 - 2.0kv
| Each | 23400.0 | 23400.0 | 2.0 | False | None | None | False | None | False | 46800.0 | 0 | 2686524 | 84181 | None | 6.1 | Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.
| Each | 1492.0 | 1492.0 | 4.0 | False | None | None | False | None | False | 5968.0 | 0 | 2686525 | 84181 | None | 6.2.1 | Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 12" Sweep (300 mm)
| Each | 2969.0 | 2969.0 | 2.0 | False | None | None | False | None | False | 5938.0 | 0 | 2686526 | 84181 | None | 6.4.1 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 48" Sweep 5 Star (1200 mm)
| Each | 2677.0 | 2677.0 | 42.0 | False | None | None | False | None | False | 112434.0 | 0 | 2686527 | 84181 | None | 9.3.3 | Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries
and wiring complete. 5 kVA ON LINE UPS
| Each | 68383.0 | 68383.0 | 2.0 | False | None | None | False | None | False | 136766.0 | 0 | 2686528 | 84181 | None | 9.4.5 | Supplying, installation, testing & commissioning of 12V .AH batteries in poly propylene container for D.G. sets. Low maintenance batteries, plate type. 120 AH capacity
| Each | 23331.0 | 23331.0 | 12.0 | False | None | None | False | None | False | 279972.0 | 0 | 2686529 | 84181 | None | 11.2.1 | Supplying fixing retrofit typepLED Lamp . W LED linear source with CCT 6500 degree K, CRI 70. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5 of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to275 V. Tested by NABL CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 8 9 W
| Each | 623.0 | 623.0 | 10.0 | False | None | None | False | None | False | 6230.0 | 0 | 2686530 | 84181 | None | 11.3.1 | Supplying of .feet -PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours 70 lumen maintenance with CRI 80. Power Input: 220-240V 50 60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2 - 9 10 W
| Each | 551.0 | 551.0 | 4.0 | False | None | None | False | None | False | 2204.0 | 0 | 2686531 | 84181 | None | 11.3.2 | Supplying of .feet -PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & 70 lumen maintenance with CRI 80. Power Input: 220-240V 50 60Hz Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20 22 W
| Each | 690.0 | 690.0 | 20.0 | False | None | None | False | None | False | 13800.0 | 0 | 2686532 | 84181 | None | 11.5.3 | Supply of round/square recess/surface mounted rolling type LED Down light with . W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V 50 60Hz & Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working
under standard electrical condition LED square or round down light 15 18W
| Each | 1324.0 | 1324.0 | 151.0 | False | None | None | False | None | False | 199924.0 | 0 | 2686533 | 84181 | None | 11.6.3 | Supplying of recess mounting non integral type . LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70. efficacy 100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5 of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 2'x2' 36 W
| Each | 4553.0 | 4553.0 | 2.0 | False | None | None | False | None | False | 9106.0 | 0 | 2686534 | 84181 | None | 13.7.1 | Fixing charges On wall/ ceiling / Rafter / Girders
| Each | 122.0 | 122.0 | 160.0 | False | None | None | False | None | False | 19520.0 | 0 | 2686535 | 84181 | None | 13.10 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.
| Each | 171.0 | 171.0 | 42.0 | False | None | None | False | None | False | 7182.0 | 0 | 2686536 | 84181 | None | 13.12 | Extra length of GI pipe of class B 19mm dia for down rod.
| m | 197.0 | 197.0 | 42.0 | False | None | None | False | None | False | 8274.0 | 0 | 2686537 | 84181 | None | 13.13 | Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of
approved make with wire mesh and wooden frame.
| Each | 707.0 | 707.0 | 6.0 | False | None | None | False | None | False | 4242.0 | 0 | 2686538 | 84181 | None | 12.57 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40 mm dia 2.9 mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400 mm with a cast iron cover. The earth electrode shall have staggered holes of 12 mm dia and the electrode should be covered 150 mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.
| No | 4256.0 | 4256.0 | 10.0 | False | None | None | False | None | False | 42560.0 | 0 | 2686539 | 84181 | None | 12.58.2 | GI/Copper strips for grounding connections, using necessary fixing
materials as required. 25 x 3 mm GI strip
| m | 82.0 | 82.0 | 60.0 | False | None | None | False | None | False | 4920.0 | 0 | 2686540 | 84181 | None | 12.58.7 | GI/Copper strips for grounding connections, using necessary fixing
materials as required. 25 by 3 mm Copper strip
| m | 570.0 | 570.0 | 30.0 | False | None | None | False | None | False | 17100.0 | 0 |
| 1708243424000 | 0 | None | None | Buildings | Water Supply and Sanitary | 448905.92 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2686541 | 84182 | None | A-44 | 652 PVC pipe - OD 25mm and 10 Kg/sqcm m (VOL -5 , PAGE NO-A-44). | m | 23.0 | 23.0 | 160.0 | False | None | None | False | None | False | 3680.0 | 0 | 2686542 | 84182 | None | A-44 | 654 PVC pipe - OD 32mm and 10 Kg/sqcm m (VOL -5 , PAGE NO-A-44). | m | 33.0 | 33.0 | 50.0 | False | None | None | False | None | False | 1650.0 | 0 | 2686543 | 84182 | None | 2.82.1 | 2.82 Supply of PPR Double Union Ball Valveconfirming to IS 15801-2008 and
DIN Standards 8077/8092 2.82.1 PPR Double Union Ball Valve 20mm
| No | 789.0 | 789.0 | 10.0 | False | None | None | False | None | False | 7890.0 | 0 | 2686544 | 84182 | None | 2.82.2 | 2.82 Supply of PPR Double Union Ball Valveconfirming to IS 15801-2008 and
DIN Standards 8077/8092
2.82.2 PPR Double Union Ball Valve 25mm
| No | 1076.0 | 1076.0 | 10.0 | False | None | None | False | None | False | 10760.0 | 0 | 2686545 | 84182 | None | 2.82.3 | 2.82 Supply of PPR Double Union Ball Valveconfirming to IS 15801-2008 and
DIN Standards 8077/8092
2.82.3 PPR Double Union Ball Valve 32mm | No | 1784.0 | 1784.0 | 6.0 | False | None | None | False | None | False | 10704.0 | 0 | 2686546 | 84182 | None | 2.78.2 | 2.78 Supply of PPR Male Threaded Elbow confirming to IS 15801-2008 and
DIN Standards 2.78.2 PPR Male Threaded Elbow 20X1/2mm
8077/8092 | No | 82.0 | 82.0 | 20.0 | False | None | None | False | None | False | 1640.0 | 0 | 2686547 | 84182 | None | 2.78.3 | 2.78 Supply of PPR Male Threaded Elbow confirming to IS 15801-2008 and
DIN Standards 8077/8092. 2.78.3 PPR Male Threaded Elbow 25X1/2mm
| No | 98.0 | 98.0 | 15.0 | False | None | None | False | None | False | 1470.0 | 0 | 2686548 | 84182 | None | 2.78.5 | 2.78 Supply of PPR Male Threaded Elbow confirming to IS 15801-2008 and
DIN Standards 8077/8092. 2.78.5 PPR Male Threaded Elbow 32X1/2mm
| No | 130.0 | 130.0 | 5.0 | False | None | None | False | None | False | 650.0 | 0 | 2686549 | 84182 | None | 2.77.2 | 2.77 Supply of PPR Female Threaded Elbow confirming to IS 15801-2008
and DIN Standards 8077/8092" 2.77.2 PPR Female Threaded Elbow 20X1/2mm
| No | 56.0 | 56.0 | 20.0 | False | None | None | False | None | False | 1120.0 | 0 | 2686550 | 84182 | None | 2.77.3 | 2.77 Supply of PPR Female Threaded Elbow confirming to IS 15801-2008
and DIN Standards 8077/8092" 2.77.3 PPR Female Threaded Elbow 25X1/2mm
| No | 70.0 | 70.0 | 15.0 | False | None | None | False | None | False | 1050.0 | 0 | 2686551 | 84182 | None | 2.77.5 | 2.77 Supply of PPR Female Threaded Elbow confirming to IS 15801-2008
and DIN Standards 8077/8092" 2.77.5 PPR Female Threaded Elbow 32X1/2mm
| No | 112.0 | 112.0 | 5.0 | False | None | None | False | None | False | 560.0 | 0 | 2686552 | 84182 | None | 2.75.2 | 2.75 Supply of PPR Female Threaded TEE confirming to IS 15801-2008 and
DIN Standards 8077/8092
2.75.2 PPR Female Threaded TEE 20X1/2mm | No | 60.0 | 60.0 | 5.0 | False | None | None | False | None | False | 300.0 | 0 | 2686553 | 84182 | None | 2.75.3 | 2.75 Supply of PPR Female Threaded TEE confirming to IS 15801-2008 and
DIN Standards 8077/8092
"
2.75.3 PPR Female Threaded TEE 25X1/2mm
| No | 74.0 | 74.0 | 15.0 | False | None | None | False | None | False | 1110.0 | 0 | 2686554 | 84182 | None | 2.75.5 | 2.75 Supply of PPR Female Threaded TEE confirming to IS 15801-2008 and
DIN Standards 8077/8092
"2.75.5 PPR Female Threaded TEE 32X1/2mm
| No | 119.0 | 119.0 | 4.0 | False | None | None | False | None | False | 476.0 | 0 | 2686555 | 84182 | None | 13.34 | 13.34 Providing and placing on terrace (at all floor levels) polyethylene
water storage tank, IS : 12701 marked, with cover and suitable locking
arrangement and making necessary holes for inlet, outlet and overflow
pipes but without fittings and the base support for tank.
| l | 9.0 | 9.0 | 4000.0 | False | None | None | False | None | False | 36000.0 | 0 | 2686556 | 84182 | None | 13.6.1.1 | 13.6.1.1 Providing and fixing gun metal non- return valve of approved quality
(screwed end) : 25 mm nominal bore-Horizontal | No | 1361.0 | 1361.0 | 5.0 | False | None | None | False | None | False | 6805.0 | 0 | 2686557 | 84182 | None | 13.3.2 | 13.3.2 Providing and fixing brass stop cock of approved quality : 20 mm nominal bore | No | 305.0 | 305.0 | 12.0 | False | None | None | False | None | False | 3660.0 | 0 | 2686558 | 84182 | None | 13.6.2 | 13.6.2.2Providing and fixing gun metal non- return valve of approved quality
(screwed end) :32 mm nominal bore | No | 925.0 | 925.0 | 5.0 | False | None | None | False | None | False | 4625.0 | 0 | 2686559 | 84182 | None | 1.6.1 | 1.6.1 Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.In all kinds of soils. Depth upto 1.50m | m | 484.0 | 484.0 | 16.88 | False | None | None | False | None | False | 8169.92 | 0 | 2686560 | 84182 | None | A-43 | 633 Poly Propylene Random Co-polymer (PPR) pipe with fitting SDR
7.4 -50 mm Outer dia (VOL -5 , PAGE NO-A-43). | m | 381.0 | 381.0 | 20.0 | False | None | None | False | None | False | 7620.0 | 0 | 2686561 | 84182 | None | 14.3.1 | 14.3.1 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid | No | 5977.0 | 5977.0 | 6.0 | False | None | None | False | None | False | 35862.0 | 0 | 2686562 | 84182 | None | 14.7.3 | 14.7.3 White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps | No | 2866.0 | 2866.0 | 11.0 | False | None | None | False | None | False | 31526.0 | 0 | 2686563 | 84182 | None | 14.4.1 | 14.4.1 Providing and fixing white vitreous china flat back or wall corner type
lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern | No | 4454.0 | 4454.0 | 5.0 | False | None | None | False | None | False | 22270.0 | 0 | 2686564 | 84182 | None | 14.31 | 14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. | No | 1220.0 | 1220.0 | 11.0 | False | None | None | False | None | False | 13420.0 | 0 | 2686565 | 84182 | None | 14.40.2 | 14.40.2 600 mm long towel rail with total length of 645 mm, 78 mm wide and effective height of 88 mm, weighing not less than 190 g. | No | 496.0 | 496.0 | 6.0 | False | None | None | False | None | False | 2976.0 | 0 | 2686566 | 84182 | None | 13.46 | 13.46 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors: 100 mm inlet and 75mm outlet, hubless centrifugally cast (spun) iron epoxy coated inside and outside IS: 15905 (REFER 1st Corrigendum and Addendum order - 21-04-2022) | Each | 475.0 | 475.0 | 12.0 | False | None | None | False | None | False | 5700.0 | 0 | 2686567 | 84182 | None | 9.3.4 | 9.3.4 .Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0 HDPE Grade PE80-PN10.0,110mm dia
| m | 650.0 | 650.0 | 45.0 | False | None | None | False | None | False | 29250.0 | 0 | 2686568 | 84182 | None | 16.8 | 16.8 Constructing brick masonry chamber of internal dimension 600x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover | No | 4791.0 | 4791.0 | 6.0 | False | None | None | False | None | False | 28746.0 | 0 | 2686569 | 84182 | None | 16.10 | 16.10 Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. | No | 4236.0 | 4236.0 | 6.0 | False | None | None | False | None | False | 25416.0 | 0 | 2686570 | 84182 | None | 13.32.2 | 13.32.2. Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipes | m | 379.0 | 379.0 | 75.0 | False | None | None | False | None | False | 28425.0 | 0 | 2686571 | 84182 | None | 13.33.3 | 13.33.3 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 25 mm nominal dia Pipes | m | 296.0 | 296.0 | 65.0 | False | None | None | False | None | False | 19240.0 | 0 | 2686572 | 84182 | None | A-44 | 647 PVC pipe - OD 110mm and 6 Kg/sqcm (VOL -5 , PAGE NO-A-44). | m | 255.0 | 255.0 | 230.0 | False | None | None | False | None | False | 58650.0 | 0 | 2686573 | 84182 | None | A-45 | 680 PVC pipes of 8 Kg/cm2 for 75mm(0.917)m (VOL -5 , PAGE NO-A-45). | m | 142.0 | 142.0 | 110.0 | False | None | None | False | None | False | 15620.0 | 0 | 2686574 | 84182 | None | 10.9.6 | M100 Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments
10.9.6 - 75 mm dia PVC Elbows
| Each | 192.0 | 192.0 | 45.0 | False | None | None | False | None | False | 8640.0 | 0 | 2686575 | 84182 | None | 10.9.8 | M100 Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments
10.9.8 - 110 mm dia PVC Elbows
10.9.8 - 110 mm dia PVC Elbows | Each | 302.0 | 302.0 | 30.0 | False | None | None | False | None | False | 9060.0 | 0 | 2686576 | 84182 | None | 2.76.2 | 2.76 Supply of PPR Male Threaded TEE confirming to IS 15801-2008 and
DIN Standards 8077/8092. 2.76.2 PPR Male Threaded TEE 20X1/2mm
| No | 92.0 | 92.0 | 15.0 | False | None | None | False | None | False | 1380.0 | 0 | 2686577 | 84182 | None | 2.76.3 | 2.76 Supply of PPR Male Threaded TEE confirming to IS 15801-2008 and
DIN Standards 8077/8092. 2.76.3 PPR Male Threaded TEE 25X1/2mm | No | 102.0 | 102.0 | 20.0 | False | None | None | False | None | False | 2040.0 | 0 | 2686578 | 84182 | None | 2.76.5 | 2.76 Supply of PPR Male Threaded TEE confirming to IS 15801-2008 and
DIN Standards 8077/8092. 2.76.5 PPR Male Threaded TEE 32X1/2mm | No | 149.0 | 149.0 | 5.0 | False | None | None | False | None | False | 745.0 | 0 |
| 1708243424000 | 1 | None | None | Buildings | Second floor Parapet wall | 331796.93 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2686579 | 84183 | None | 2.5.2 | 2.5.2 Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 6979.86 | 6979.86 | 2.196 | False | None | None | False | None | False | 15327.77256 | 0 | 2686580 | 84183 | None | Addendum 1 70 percent | FORMWORK FOR COLUMN: Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 4885.9 | 4885.9 | 2.196 | False | None | None | False | None | False | 10729.4364 | 0 | 2686581 | 84183 | None | 2.11 | 2.11 Steel Fabrication Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings
| Tonne | 91246.14 | 91246.14 | 0.55 | False | None | None | False | None | False | 50185.377 | 0 | 2686582 | 84183 | None | 2.1.4 | 2.1.4 Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 6341.34 | 6341.34 | 0.99 | False | None | None | False | None | False | 6277.9266 | 0 | 2686583 | 84183 | None | 6.2 | 6.2 Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.
| Cum | 8137.56 | 8137.56 | 12.26 | False | None | None | False | None | False | 99766.4856 | 0 | 2686584 | 84183 | None | 8.8 | 8.8 Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 378.42 | 378.42 | 152.12 | False | None | None | False | None | False | 57565.2504 | 0 | 2686585 | 84183 | None | 8.29 | 8.29 Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 288.66 | 288.66 | 152.12 | False | None | None | False | None | False | 43910.9592 | 0 | 2686586 | 84183 | None | 15.1 | 15.1 Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.
| Sqm | 833.34 | 833.34 | 57.64 | False | None | None | False | None | False | 48033.7176 | 0 |
| 1708243424000 | 0 | None | None | Buildings | SUMP TANK,SEPTIK TANK & SOAK PIT | 603971.62 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2686587 | 84184 | None | 1.14.1 | 1.14.1 Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 102.0 | 102.0 | 46.655 | False | None | None | False | None | False | 4758.81 | 0 | 2686588 | 84184 | None | 6.4 | 6.4 Providing and Filling in foundation with granite I trap broken metal 1OOmm. and down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift. complete as per specifications. specification. VOLUME 2 | Cum | 1593.0 | 1593.0 | 4.116 | False | None | None | False | None | False | 6556.788 | 0 | 2686589 | 84184 | None | 2.1.3 | 2.1.3 Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5989.0 | 5989.0 | 4.587 | False | None | None | False | None | False | 27471.543 | 0 | 2686590 | 84184 | None | 6.2 | 6.2 Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 7978.0 | 7978.0 | 1.6767 | False | None | None | False | None | False | 13376.7126 | 0 | 2686591 | 84184 | None | 8.2.2 | 8.2.2 Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 279.0 | 279.0 | 68.1 | False | None | None | False | None | False | 18999.9 | 0 | 2686592 | 84184 | None | 8.12 | 8.12 Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer- in-Charge. | Sqm | 64.0 | 64.0 | 68.1 | False | None | None | False | None | False | 4358.4 | 0 | 2686593 | 84184 | None | 8.11 | 8.11 Providing Neat cement punning to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 57.0 | 57.0 | 68.1 | False | None | None | False | None | False | 3881.7 | 0 | 2686594 | 84184 | None | 2.5.1 | 2.5.1 Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 6630.0 | 6630.0 | 14.532 | False | None | None | False | None | False | 96347.16 | 0 | 2686595 | 84184 | None | Addendum-1 | FORMWORK FOR Sump & Septic Tank @ 35 % of the rate of above concrete item : Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 2320.5 | 2320.5 | 14.532 | False | None | None | False | None | False | 33721.506 | 0 | 2686596 | 84184 | None | 2.11 a | 2.11 Steel Fabrication
Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft
annealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings | Tonne | 89457.0 | 89457.0 | 3.5 | False | None | None | False | None | False | 313099.5 | 0 | 2686597 | 84184 | None | 18.3 | 18.3 Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. | Each | 1962.0 | 1962.0 | 2.0 | False | None | None | False | None | False | 3924.0 | 0 | 2686598 | 84184 | None | 15.6 | 15.6 Providing and laying water proofing treatment to the Water tanks & Liquid Retaining structures with two component acrylic polymer modified cementitious waterproofing membrane with minimum elongation of 50% applied @ 1.5 kg/m2 for internal side waterproofing in two layers with waiting period of 4-6 hrs per layer and food grade epoxy coating in two coats certified by CFTRI Mysuru, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 507.0 | 507.0 | 67.14 | False | None | None | False | None | False | 34039.98 | 0 | 2686599 | 84184 | None | 17.1 | 17.1 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge | Cum | 1002.0 | 1002.0 | 2.355 | False | None | None | False | None | False | 2359.71 | 0 | 2686600 | 84184 | None | A-38 vol 1 | 40 mm down size A-38 (volume 1)
| Cum | 1190.0 | 1190.0 | 1.57 | False | None | None | False | None | False | 1868.3 | 0 | 2686601 | 84184 | None | A-38 vol 1 | 20 mm down size A-38 (volume 1) | Cum | 1333.0 | 1333.0 | 1.57 | False | None | None | False | None | False | 2092.81 | 0 | 2686602 | 84184 | None | 17.3 | 17.3 Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. (Volume 2)
| Cum | 1192.0 | 1192.0 | 1.57 | False | None | None | False | None | False | 1871.44 | 0 | 2686603 | 84184 | None | 17.13 | 17.13 Providing and laying 100mm thick side wall & bottom slab and of 600mm width for drain with opening using M20 concrete reinforced with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 150mm spacing jointed in CM 1:3 proportion and nicely finished Including providing holes in the walls wherever necessary including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. | m | 5612.0 | 5612.0 | 6.28 | False | None | None | False | None | False | 35243.36 | 0 |
| 1708243424000 | 1 | None | None | Buildings | SOUVENIR SHOP | 2088143.8 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2686604 | 84185 | None | 1.12 | 1.12 Earth work in surface excavation by mechanical means for lowering &leveling the ground for all works other than foundation in all kinds ofsoils & upto depth not exceeding 300mm as per drawing and technicalspecifications, including setting out, shoring, strutting,barricading,caution lights, removal of stumps and other deleterious matter includingdressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radiusof 50 m and lift upto 1.5 m including cost of labour, tools, usage ofmachinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth
| Cum | 95.0 | 95.0 | 36.72 | False | None | None | False | None | False | 3488.4 | 0 | 2686605 | 84185 | None | 1.14.1 | 1.14.1 Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m
| Cum | 102.0 | 102.0 | 142.36 | False | None | None | False | None | False | 14520.72 | 0 | 2686606 | 84185 | None | 4.1 | 4.1 Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ( Vol.2, P.No.5,I.No.4.1)
| Sqm | 118.0 | 118.0 | 134.06 | False | None | None | False | None | False | 15819.08 | 0 | 2686607 | 84185 | None | 1.23 | 1.23 Providing and Filling in foundation with granite / trap broken metal 100mm. and down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications.
| Cum | 2682.0 | 2682.0 | 13.923 | False | None | None | False | None | False | 37341.486 | 0 | 2686608 | 84185 | None | 2.1.3 | 2.1.3 Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates
| Cum | 5989.0 | 5989.0 | 22.92 | False | None | None | False | None | False | 137267.88 | 0 | 2686609 | 84185 | None | 2.2.3 | 2.2.3 Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 6336.0 | 6336.0 | 12.78 | False | None | None | False | None | False | 80974.08 | 0 | 2686610 | 84185 | None | Addendum 8 percent | FORMWORK FOR FOOTING: Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 506.88 | 506.88 | 12.78 | False | None | None | False | None | False | 6477.9264 | 0 | 2686611 | 84185 | None | 2.4.3 | 2.4.3 Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement & formwork to be paid separately)
| Cum | 6336.0 | 6336.0 | 6.37 | False | None | None | False | None | False | 40360.32 | 0 | 2686612 | 84185 | None | addendum 50percent | FORMWORK FOR PLINTH BEAM: Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement to be paid separately)
| Cum | 3168.0 | 3168.0 | 6.37 | False | None | None | False | None | False | 20180.16 | 0 | 2686613 | 84185 | None | 2.5.2 | 2.5.2 Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 6843.0 | 6843.0 | 4.37 | False | None | None | False | None | False | 29903.91 | 0 | 2686614 | 84185 | None | addendum 70percent | FORMWORK FOR COLUMN FROM FOOTING TO PLINTH TOP: Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement to be paid separately)
| Cum | 4790.1 | 4790.1 | 4.37 | False | None | None | False | None | False | 20932.737 | 0 | 2686615 | 84185 | None | 2.5.2 | 2.5.2 Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 6843.0 | 6843.0 | 4.86 | False | None | None | False | None | False | 33256.98 | 0 | 2686616 | 84185 | None | addendum 70per | FORMWORK FOR COLUMN : Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 4790.1 | 4790.1 | 4.86 | False | None | None | False | None | False | 23279.886 | 0 | 2686617 | 84185 | None | 2.5.2 | 2.5.2 Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 6843.0 | 6843.0 | 10.57 | False | None | None | False | None | False | 72330.51 | 0 | 2686618 | 84185 | None | addendum 60 percent | FORMWORK FOR LINTEL, SLAB BEAM :Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement to be paid separately)
| Cum | 4105.8 | 4105.8 | 10.57 | False | None | None | False | None | False | 43398.306 | 0 | 2686619 | 84185 | None | 2.5.2 | 2.5.2 Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 6843.0 | 6843.0 | 20.95 | False | None | None | False | None | False | 143360.85 | 0 | 2686620 | 84185 | None | addendum 50 percent | FORMWORK FOR SLAB : Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 3421.5 | 3421.5 | 20.95 | False | None | None | False | None | False | 71680.425 | 0 | 2686621 | 84185 | None | 5.4 | 5.4 Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)
| Cum | 6389.0 | 6389.0 | 26.89 | False | None | None | False | None | False | 171800.21 | 0 | 2686622 | 84185 | None | 1.8 | 1.8 Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.
| Cum | 474.0 | 474.0 | 183.51 | False | None | None | False | None | False | 86983.74 | 0 | 2686623 | 84185 | None | 2.11 | 2.11 Steel Fabrication Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings
| Tonne | 89457.0 | 89457.0 | 6.25 | False | None | None | False | None | False | 559106.25 | 0 | 2686624 | 84185 | None | 2.1.4 | 2.1.4 Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 6217.0 | 6217.0 | 0.093 | False | None | None | False | None | False | 578.181 | 0 | 2686625 | 84185 | None | 11.34A | 11.34A Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding
| Kgs | 168.0 | 168.0 | 56.7 | False | None | None | False | None | False | 9525.6 | 0 | 2686626 | 84185 | None | 12.84 | 12.84 Providing & fixing of 2track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made (Volume 2 Page No 110 Item No. 12.84)
| Sqm | 5023.0 | 5023.0 | 2.7 | False | None | None | False | None | False | 13562.1 | 0 | 2686627 | 84185 | None | 8.3.1 | 8.3.1 Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 354.0 | 354.0 | 47.04 | False | None | None | False | None | False | 16652.16 | 0 | 2686628 | 84185 | None | 8.8 | 8.8 Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 371.0 | 371.0 | 110.83 | False | None | None | False | None | False | 41117.93 | 0 | 2686629 | 84185 | None | 8.1.1 | 8.1.1 Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 255.0 | 255.0 | 85.73 | False | None | None | False | None | False | 21861.15 | 0 | 2686630 | 84185 | None | 8.51 | 8.51 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.
| Sqm | 100.0 | 100.0 | 196.33 | False | None | None | False | None | False | 19633.0 | 0 | 2686631 | 84185 | None | 9.30 | 9.30 Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.
| Sqm | 5328.0 | 5328.0 | 3.0 | False | None | None | False | None | False | 15984.0 | 0 | 2686632 | 84185 | None | 9.21.2 | 9.21.2 Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm
| Sqm | 1238.0 | 1238.0 | 74.28 | False | None | None | False | None | False | 91958.64 | 0 | 2686633 | 84185 | None | 8.63 | 8.63 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: One coats on old work as per specifications and as per directions of Engineer in charge.
| Sqm | 82.0 | 82.0 | 196.33 | False | None | None | False | None | False | 16099.06 | 0 | 2686634 | 84185 | None | 8.29 | 8.29 Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 283.0 | 283.0 | 157.87 | False | None | None | False | None | False | 44677.21 | 0 | 2686635 | 84185 | None | 8.34.3 | 8.34.3 Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 50.0 | 50.0 | 2.7 | False | None | None | False | None | False | 135.0 | 0 | 2686636 | 84185 | None | 8.40 | 8.40 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 115.0 | 115.0 | 2.7 | False | None | None | False | None | False | 310.5 | 0 | 2686637 | 84185 | None | 11.28 | 11.28 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,
| Kgs | 565.0 | 565.0 | 20.8 | False | None | None | False | None | False | 11752.0 | 0 | 2686638 | 84185 | None | 11.37.3 | 11.37.3 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 8 mm thickness (weight not less than 20 kg/ m²) including cost of materials, labour, usage charges of machinery complete as per specifications.
| Sqm | 1305.0 | 1305.0 | 30.86 | False | None | None | False | None | False | 40272.3 | 0 | 2686639 | 84185 | None | 12.49 | 12.49 Providing and fixing in position fully glazed shutters for ventilators side hung or central pivoted with Honne wood stiles and rails of 30mm thick 50mm wide and central divider of 30mm. wide, 3mm thick reeded glass fixed with wooden beading of size 10mm wide flushed to the thickness of the frame including cost of materials, labour charges, usage charges complete as per specifications. (excluding cost of fixtures)
| Sqm | 6523.0 | 6523.0 | 5.92 | False | None | None | False | None | False | 38616.16 | 0 | 2686640 | 84185 | None | 7.25.1 | 7.25.1. Providing and fixing plain multipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete. 6 mm thick Cement fiber board as per IS: 14862
| Sqm | 635.0 | 635.0 | 146.37 | False | None | None | False | None | False | 92944.95 | 0 |
|
|
---|