createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1708672493868
version7
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd496750.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose25-03-2024 17:00:00
tenderQueryClose13-03-2024 17:00:00
technicalBidOpen27-03-2024 11:00:00
publishedDate23-02-2024 13:28:03
publishedByPostKMF_MNG_ENGG_MUL_MDY
publishedByUserKPE13467 - SHIVA KUMAR V
bidValidityPeriod90
noOfCalls2
preBidMeetingDate13-03-2024 13:33:52
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnTrue
percentageRateTypeTextNone
contactPersonMANAGER ENGINEERING
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9535773140
tenderSupplierListNone
tenderSchedule
createdTs1708672493871
version10
createdDateNone
modifiedDateNone
tenderNumberKMF/2023-24/BD/WORK_INDENT73/CALL-2
titleConstruction of Pandavapura sub office for Manmul.
descriptionConstruction of Pandavapura sub office for Manmul.
categoryWORKS
categoryTextWorks
ecv49651790.70
deptNameKarnataka Co-operative Milk Producers Federation Limited
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location6824
locationNameManaging Director Mandya District Co-operative Milk Producers Societies Union Limited Engineering
provisionalAmount49675000.0
groupOverheadTotalNone
fileNumber121/2023-24
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17086724940001NoneNoneBuildingsCIVIL WORKS37126946.57
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
278015888685Nonecode01Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Complete with all lead and lift as per the instruction of the Engineer in incharge.Cum88.7288.72629.06FalseNoneNoneFalseNoneFalse55810.20320
278015988685Nonecode02Earth work excavation for Foundation by mechanical means for all works & depth 3 m to 6 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Complete with all lead and lift as per the instruction of the Engineer in incharge.Cum102.09102.09446.68FalseNoneNoneFalseNoneFalse45601.56120
278016088685Nonecode03Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. Complete with all lead and lift as per the instruction of the Engineer in incharge.Cum247.94247.94123.72FalseNoneNoneFalseNoneFalse30675.13680
278016188685Nonecode04Cost of Haulage Excluding Loading and Unloading, Loading and Unloading of Stone Boulder/Stone aggregates/Sand/Kankar/Moorum.(Tipper 10 m3). Basement floor Complete with all lead and lift as per the instruction of the Engineer in incharge.Cum488.59488.59952.02FalseNoneNoneFalseNoneFalse465147.45180
278016288685Nonecode05Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. Complete with all lead and lift as per the instruction of the Engineer in incharge.Cum100.88100.8888.5FalseNoneNoneFalseNoneFalse8927.880
278016388685Nonecode06Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier underand around the column pits, walls, trenches, basement excavation,top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications Complete with all lead and lift as per the instruction of the Engineer in incharge.Sqm115.46115.46723.76FalseNoneNoneFalseNoneFalse83565.32960
278016488685Nonecode07Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates. Ground Floor Complete with all lead and lift as per the instruction of the Engineer in incharge.Cum6961.816961.81118.26FalseNoneNoneFalseNoneFalse823303.65060
278016588685Nonecode08Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) Complete with all lead and lift as per the instruction of the Engineer in incharge.Cum6504.826504.8215.66FalseNoneNoneFalseNoneFalse101865.48120
278016688685Nonecode09Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates as per the directions and instructions of engineer in charge. Ground Floor Complete with all lead and lift as per the instruction of the Engineer in incharge.Cum7266.887266.88202.02FalseNoneNoneFalseNoneFalse1468055.09760
278016788685Nonecode10Providing, fixing and removing of formwork, Centering, shuttering and scaffolding for footing (of item No 25) complete with all lead and lift as per the direction of Engineer-In-Charge Complete with all lead and lift as per the instruction of the Engineer in incharge.Cum325.24325.24202.02FalseNoneNoneFalseNoneFalse65704.98480
278016888685Nonecode11Providing and laying in position Reinforced cement concrete for all Sub structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - complete with all lead and lift as per the direction of Engineer-In-Charge. Ground floor Complete with all lead and lift as per the instruction of the Engineer in incharge.Cum7282.687282.6853.78FalseNoneNoneFalseNoneFalse391662.53040
278016988685Nonecode12Providing, fixing and removing of formwork, Centering, shuttering and scaffolding for footing. Basement floor Complete with all lead and lift as per the instruction of the Engineer in incharge.Cum5097.875097.8712.59FalseNoneNoneFalseNoneFalse64182.18330
278017088685Nonecode13Providing, fixing and removing of formwork, Centering, shuttering and scaffolding for plinth beam, slab & staircase Substructure Works. Basement floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum3641.343641.3431.84FalseNoneNoneFalseNoneFalse115940.26560
278017188685Nonecode14Providing, fixing and removing of formwork, Centering, shuttering and scaffolding for RC wall Substructure Works. Basement floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum5097.875097.879.35FalseNoneNoneFalseNoneFalse47665.08450
278017288685Nonecode15Providing and laying in position Reinforced cement concrete for all Super structures ofbuilding , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - Ground floor Works complete with all lead and lift as per the direction of Engineer-In-ChargeCum7518.467518.46100.42FalseNoneNoneFalseNoneFalse755003.75320
278017388685Nonecode16Providing, fixing and removing of formwork, Centering, shuttering and scaffolding (of Item No 32) for column. Basement floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum5262.935262.9314.13FalseNoneNoneFalseNoneFalse74365.20090
278017488685Nonecode17Providing, fixing and removing of formwork, Centering, shuttering and scaffolding (of Item No 32) for beam & lintels. Basement floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum4511.084511.0830.74FalseNoneNoneFalseNoneFalse138670.59920
278017588685Nonecode18Providing, fixing and removing of formwork, Centering, shuttering and scaffolding (of Item No 32) for slab & staircase. Basement floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum3759.233759.2355.55FalseNoneNoneFalseNoneFalse208825.22650
278017688685Nonecode19Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeKg111.82111.8237840.77FalseNoneNoneFalseNoneFalse4231354.90140
278017788685Nonecode20Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge. Complete Ground Floor Complete with all lead and lift as per the instruction of the Engineer in incharge.Sqm856.86856.86121.6FalseNoneNoneFalseNoneFalse104194.1760
278017888685Nonecode21Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding for works Ground Floor Works complete with all lead and lift as per the direction of Engineer-In-ChargeKg176.23176.23460.95FalseNoneNoneFalseNoneFalse81233.21850
278017988685Nonecode22Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) -Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm8799.58799.513.74FalseNoneNoneFalseNoneFalse120905.130
278018088685Nonecode23Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) Ground Floor Works complete with all lead and lift as per the direction of Engineer-In-ChargeSqm8799.58799.50.9FalseNoneNoneFalseNoneFalse7919.550
278018188685Nonecode24Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum109863.65109863.650.15FalseNoneNoneFalseNoneFalse16479.54750
278018288685Nonecode25Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. do- 30 mm thick both side commercial. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm3206.233206.235.36FalseNoneNoneFalseNoneFalse17185.39280
278018388685Nonecode26Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. Ground floor complete with all lead and lift as per the direction of Engineer-In-Chargem577.32577.3223.94FalseNoneNoneFalseNoneFalse13821.04080
278018488685Nonecode27Providing and fixing factory made 100% carpenter friendly ready to use single solid plain wood polymer composite (WPC) flush shutter of 30mm thick which is anti terminate and having high water observation property. The cost include cost of material, transportation, labour and fixing charges. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm4227.164227.163.15FalseNoneNoneFalseNoneFalse13315.5540
278018588685Nonecode28Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos132.48132.483.0FalseNoneNoneFalseNoneFalse397.440
278018688685Nonecode29Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos1069.551069.553.0FalseNoneNoneFalseNoneFalse3208.650
278018788685Nonecode30Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos1011.211011.213.0FalseNoneNoneFalseNoneFalse3033.630
278018888685Nonecode31Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos212.7212.76.0FalseNoneNoneFalseNoneFalse1276.20
278018988685Nonecode32Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90mm. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos99.6699.669.0FalseNoneNoneFalseNoneFalse896.940
278019088685Nonecode33Providing and fixing bright finished brass tower bolts(barrel type) with necessary screws etc. complete : 250x10mm, Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach409.59409.599.0FalseNoneNoneFalseNoneFalse3686.310
278019188685Nonecode34Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm8444.68444.6211.77FalseNoneNoneFalseNoneFalse1788312.9420
278019288685Nonecode35Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm1086.571086.5715.39FalseNoneNoneFalseNoneFalse16722.31230
278019388685Nonecode36Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm1289.541289.54104.4FalseNoneNoneFalseNoneFalse134627.9760
278019488685Nonecode37Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge Ground Floor Works complete with all lead and lift as per the direction of Engineer-In-ChargeSqm3050.653050.6511.52FalseNoneNoneFalseNoneFalse35143.4880
278019588685Nonecode38Providing 12 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners with chicken mesh all around the wall with smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm258.88258.88405.36FalseNoneNoneFalseNoneFalse104939.59680
278019688685Nonecode39Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-incharge for works Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm301.42301.42488.94FalseNoneNoneFalseNoneFalse147376.29480
278019788685Nonecode40Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm100.88100.88894.3FalseNoneNoneFalseNoneFalse90216.9840
278019888685Nonecode41Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm373.13373.13335.98FalseNoneNoneFalseNoneFalse125364.21740
278019988685Nonecode42Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm2294.682294.6850.6FalseNoneNoneFalseNoneFalse116110.8080
278020088685Nonecode43Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm3488.23488.290.03FalseNoneNoneFalseNoneFalse314042.6460
278020188685Nonecode44Providing and fixing 20mm thick gang saw water cut Lakared granite for cladding in CM 1:3 (1 cement : 3 coarse sand) proportion with a coat of rough plastering using CM 1:4 (1 cement : 4 fine sand), cut to required shape, pattern with paper joints, finished with cement mortar using white cement and colour pigments to match the colour of slab making through jointing with sealant, grooves in joints including cost of curing etc., complete including cost and conveyance of all materials, mortar, labour for all items of work, usage charges of machinery etc., complete as per specification. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm3614.273614.275.02FalseNoneNoneFalseNoneFalse18143.63540
278020288685Nonecode45Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. Ground floor complete with all lead and lift as per the direction of Engineer-In-Chargem326.94326.9450.2FalseNoneNoneFalseNoneFalse16412.3880
278020388685Nonecode46Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. - Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm735.32735.327.95FalseNoneNoneFalseNoneFalse5845.7940
278020488685Nonecode47Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm1171.651171.6519.47FalseNoneNoneFalseNoneFalse22812.02550
278020588685Nonecode48Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm1959.221959.220.41FalseNoneNoneFalseNoneFalse803.28020
278020688685Nonecode49Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm4193.134193.130.63FalseNoneNoneFalseNoneFalse2641.67190
278020788685Nonecode50Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer in- Charge. Ground Floor complete with all lead and lift as per the direction of Engineer-In-ChargeKg134.91134.911548.0FalseNoneNoneFalseNoneFalse208840.680
278020888685Nonecode51Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm48.6248.62894.3FalseNoneNoneFalseNoneFalse43480.8660
278020988685Nonecode52Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm96.0296.02894.3FalseNoneNoneFalseNoneFalse85870.6860
278021088685Nonecode53Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm252.8252.8335.98FalseNoneNoneFalseNoneFalse84935.7440
278021188685Nonecode54Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-incharge. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm109.39109.3938.64FalseNoneNoneFalseNoneFalse4226.82960
278021288685Nonecode55Providing and laying heavy duty cobble stones 75mm thick interlock pavers, using cement and course sand for manufacture of blocks of approved size, shape and colour with a minimum compressive strength of 281 kg per m2 over 50mm thick sand bed ( average thickness ) and compacting with plate vibrator having 3 tons compaction force thereby forcing part of sand underneath to come up in between joints, final compaction of paver surface joints into its final level, including cost of materials, labour and Usage charges of machinery complete as per specifications. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum1391.631391.6361.0FalseNoneNoneFalseNoneFalse84889.430
278021388685Nonecode56Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm49.8349.838.82FalseNoneNoneFalseNoneFalse439.50060
278021488685Nonecode57Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete. up to Ground Floor.Sqm4787.464787.469.6FalseNoneNoneFalseNoneFalse45959.6160
278021588685Nonecode58Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi -rigid, inorganic, non-combustible fibre glass wool insulation 50 mm thick, conforming to IS: 8183 and BS: 3958 Part 5. The insulation layer shall have facing (factory bonded on surface 1 of the fibre glass insulation layer), of black non-woven fibre glass tissue of nominal thickness 0.5 mm and nominal mass not less than 60 g/m2,made of randomly oriented glass fibres distributed in a binder by a wet-lay process including fixing 1.5 mm thick solid aluminum sheet backing using, 6 mm thick cement board including SS rivets, nuts, bolts, washers etc complete. up to First FloorSqm1898.451898.459.6FalseNoneNoneFalseNoneFalse18225.120
278021688685Nonecode59Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in- Charge. For payment, only the actual area of glass on face 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2. (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevent Item*).“(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 K etc. . The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. Up to first floorSqm2103.862103.869.6FalseNoneNoneFalseNoneFalse20197.0560
278021788685Nonecode60Providing and fixing of clay tiles for cladding tiles of size 230x75x10mm thick on 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) & jointed with Adhesive/cement slurry over rough plaster surface excluding cost of rough plastered surface and the surface is painted with red apex paint and black apex paint into the groves. The work includes cost of all materials, labour charges for all items of work, usage charges for equipment, etc., complete as per specification.Up to first floorSqm2253.352253.359.9FalseNoneNoneFalseNoneFalse22308.1650
278021888685Nonecode61Providing and laying in position Reinforced cement concrete for all Super structures ofbuilding , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - First Floor Works complete with all lead and lift as per the direction of Engineer-In-ChargeCum7518.467518.4697.86FalseNoneNoneFalseNoneFalse735756.49560
278021988685Nonecode62Providing, fixing and removing of formwork, Centering, shuttering and scaffolding for column First floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum5262.935262.9314.13FalseNoneNoneFalseNoneFalse74365.20090
278022088685Nonecode63Providing, fixing and removing of formwork, Centering, shuttering and scaffolding (of Item No 32) for beam & lintels First floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum4511.084511.0830.05FalseNoneNoneFalseNoneFalse135557.9540
278022188685Nonecode64Providing, fixing and removing of formwork, Centering, shuttering and scaffolding (of Item No 32) for slab & staircase First floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum3759.233759.2353.69FalseNoneNoneFalseNoneFalse201833.05870
278022288685Nonecode65Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) First floor complete with all lead and lift as per the direction of Engineer-In-ChargeKg111.82111.8210570.78FalseNoneNoneFalseNoneFalse1182024.61960
278022388685Nonecode66Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm8551.558551.55256.25FalseNoneNoneFalseNoneFalse2191334.68750
278022488685Nonecode67Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm1086.571086.5745.48FalseNoneNoneFalseNoneFalse49417.20360
278022588685Nonecode68Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. First floor complete with all lead and lift as per the direction of Engineer-In-Charge.Sqm3050.653050.652.88FalseNoneNoneFalseNoneFalse8785.8720
278022688685Nonecode69Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding for works First floor complete with all lead and lift as per the direction of Engineer-In-ChargeKg176.23176.23516.6FalseNoneNoneFalseNoneFalse91040.4180
278022788685Nonecode70Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) -First floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm8799.58799.522.8FalseNoneNoneFalseNoneFalse200628.60
278022888685Nonecode71Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) First floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm5919.05919.01.8FalseNoneNoneFalseNoneFalse10654.20
278022988685Nonecode72Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum109863.65109863.650.26FalseNoneNoneFalseNoneFalse28564.5490
278023088685Nonecode73Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. do- 30 mm thick both side commercial. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm3206.233206.2312.6FalseNoneNoneFalseNoneFalse40398.4980
278023188685Nonecode74Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. Ground floor.m577.32577.3247.88FalseNoneNoneFalseNoneFalse27642.08160
278023288685Nonecode75Providing and fixing factory made 100% carpenter friendly ready to use single solid plain wood polymer composite (WPC) flush shutter of 30mm thick which is anti terminate and having high water observation property. The cost include cost of material, transportation, labour and fixing charges. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm4227.164227.166.3FalseNoneNoneFalseNoneFalse26631.1080
278023388685Nonecode76Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos132.48132.486.0FalseNoneNoneFalseNoneFalse794.880
278023488685Nonecode77Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos1069.551069.556.0FalseNoneNoneFalseNoneFalse6417.30
278023588685Nonecode78Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos1011.211011.216.0FalseNoneNoneFalseNoneFalse6067.260
278023688685Nonecode79Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos212.7212.712.0FalseNoneNoneFalseNoneFalse2552.40
278023788685Nonecode80Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90mm. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos99.6699.6618.0FalseNoneNoneFalseNoneFalse1793.880
278023888685Nonecode81Providing and fixing bright finished brass tower bolts(barrel type) with necessary screws etc. complete : 250x10mm, First floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach409.59409.5918.0FalseNoneNoneFalseNoneFalse7372.620
278023988685Nonecode82Providing 12 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners with chicken mesh all around the wall with smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm258.88258.88345.43FalseNoneNoneFalseNoneFalse89424.91840
278024088685Nonecode83Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-incharge for works First floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm301.42301.42554.77FalseNoneNoneFalseNoneFalse167218.77340
278024188685Nonecode84Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm100.88100.88900.21FalseNoneNoneFalseNoneFalse90813.18480
278024288685Nonecode85Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm373.13373.13293.0FalseNoneNoneFalseNoneFalse109327.090
278024388685Nonecode86Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm2294.682294.6850.6FalseNoneNoneFalseNoneFalse116110.8080
278024488685Nonecode87Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm3488.23488.2267.45FalseNoneNoneFalseNoneFalse932919.090
278024588685Nonecode88Providing and fixing 20mm thick gang saw water cut Lakared granite for cladding in CM 1:3 (1 cement : 3 coarse sand) proportion with a coat of rough plastering using CM 1:4 (1 cement : 4 fine sand), cut to required shape, pattern with paper joints, finished with cement mortar using white cement and colour pigments to match the colour of slab making through jointing with sealant, grooves in joints including cost of curing etc., complete including cost and conveyance of all materials, mortar, labour for all items of work, usage charges of machinery etc., complete as per specification. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm4251.474251.4711.07FalseNoneNoneFalseNoneFalse47063.77290
278024688685Nonecode89Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. First floor complete with all lead and lift as per the direction of Engineer-In-Chargem326.94326.94187.6FalseNoneNoneFalseNoneFalse61333.9440
278024788685Nonecode90Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. - First floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm735.32735.3222.35FalseNoneNoneFalseNoneFalse16434.4020
278024888685Nonecode91Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm1171.651171.6598.07FalseNoneNoneFalseNoneFalse114903.71550
278024988685Nonecode92Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm1959.221959.221.22FalseNoneNoneFalseNoneFalse2390.24840
278025088685Nonecode93Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm4193.134193.131.26FalseNoneNoneFalseNoneFalse5283.34380
278025188685Nonecode94Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer in- Charge. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeKg134.91134.91504.0FalseNoneNoneFalseNoneFalse67994.640
278025288685Nonecode95Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm48.6248.62900.21FalseNoneNoneFalseNoneFalse43768.21020
278025388685Nonecode96Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm96.0296.02900.21FalseNoneNoneFalseNoneFalse86438.16420
278025488685Nonecode97Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm252.8252.8293.0FalseNoneNoneFalseNoneFalse74070.40
278025588685Nonecode98Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-incharge First floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm109.39109.3927.48FalseNoneNoneFalseNoneFalse3006.03720
278025688685Nonecode99Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm49.8349.8318.9FalseNoneNoneFalseNoneFalse941.7870
278025788685Nonecode100Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete. up to First Floor.Sqm4787.464787.469.6FalseNoneNoneFalseNoneFalse45959.6160
278025888685Nonecode101Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi -rigid, inorganic, non-combustible fibre glass wool insulation 50 mm thick, conforming to IS: 8183 and BS: 3958 Part 5. The insulation layer shall have facing (factory bonded on surface 1 of the fibre glass insulation layer), of black non-woven fibre glass tissue of nominal thickness 0.5 mm and nominal mass not less than 60 g/m2,made of randomly oriented glass fibres distributed in a binder by a wet-lay process including fixing 1.5 mm thick solid aluminum sheet backing using, 6 mm thick cement board including SS rivets, nuts, bolts, washers etc complete. up to First floor.Sqm1898.451898.459.6FalseNoneNoneFalseNoneFalse18225.120
278025988685Nonecode102Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in- Charge. For payment, only the actual area of glass on face 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2. (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevent Item*).“(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 K etc. . The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. Up to first floorSqm2103.862103.869.6FalseNoneNoneFalseNoneFalse20197.0560
278026088685Nonecode103Providing and fixing of clay tiles for cladding tiles of size 230x75x10mm thick on 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) & jointed with Adhesive/cement slurry over rough plaster surface excluding cost of rough plastered surface and the surface is painted with red apex paint and black apex paint into the groves. The work includes cost of all materials, labour charges for all items of work, usage charges for equipment, etc., complete as per specification.Up to first floorSqm2253.352253.359.9FalseNoneNoneFalseNoneFalse22308.1650
278026188685Nonecode104Providing and laying in position Reinforced cement concrete for all Super structures ofbuilding , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - Second Floor Works complete with all lead and lift as per the direction of Engineer-In-ChargeCum7518.467518.46136.43FalseNoneNoneFalseNoneFalse1025743.49780
278026288685Nonecode105Providing, fixing and removing of formwork, Centering, shuttering and scaffolding for column Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum5262.935262.9312.24FalseNoneNoneFalseNoneFalse64418.26320
278026388685Nonecode106Providing, fixing and removing of formwork, Centering, shuttering and scaffolding (of Item No 32) for beam & lintels. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum4511.084511.0881.17FalseNoneNoneFalseNoneFalse366164.36360
278026488685Nonecode107Providing, fixing and removing of formwork, Centering, shuttering and scaffolding (of Item No 32) for slab & staircase. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum3759.233759.2343.02FalseNoneNoneFalseNoneFalse161722.07460
278026588685Nonecode108Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeKg111.82111.8215643.35FalseNoneNoneFalseNoneFalse1749239.3970
278026688685Nonecode109Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm1453.621453.62232.22FalseNoneNoneFalseNoneFalse337559.63640
278026788685Nonecode110Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm1142.481142.4845.48FalseNoneNoneFalseNoneFalse51959.99040
278026888685Nonecode111Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. -Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum2451.462451.464.5FalseNoneNoneFalseNoneFalse11031.570
278026988685Nonecode112Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Second floor complete with all lead and lift as per the direction of Engineer-In-Charge.Sqm3050.653050.652.88FalseNoneNoneFalseNoneFalse8785.8720
278027088685Nonecode113Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding for works. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeKg176.23176.23554.4FalseNoneNoneFalseNoneFalse97701.9120
278027188685Nonecode114Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) -Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm8799.58799.524.6FalseNoneNoneFalseNoneFalse216467.70
278027288685Nonecode115Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm5919.05919.01.8FalseNoneNoneFalseNoneFalse10654.20
278027388685Nonecode116Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum109863.65109863.650.26FalseNoneNoneFalseNoneFalse28564.5490
278027488685Nonecode117Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. do- 30 mm thick both side commercial. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm3206.233206.2312.6FalseNoneNoneFalseNoneFalse40398.4980
278027588685Nonecode118Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. Second floor.m577.32577.3247.88FalseNoneNoneFalseNoneFalse27642.08160
278027688685Nonecode119Providing and fixing factory made 100% carpenter friendly ready to use single solid plain wood polymer composite (WPC) flush shutter of 30mm thick which is anti terminate and having high water observation property. The cost include cost of material, transportation, labour and fixing charges. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm4227.164227.166.3FalseNoneNoneFalseNoneFalse26631.1080
278027788685Nonecode120Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos132.48132.486.0FalseNoneNoneFalseNoneFalse794.880
278027888685Nonecode121Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos1069.551069.556.0FalseNoneNoneFalseNoneFalse6417.30
278027988685Nonecode122Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos1011.211011.216.0FalseNoneNoneFalseNoneFalse6067.260
278028088685Nonecode123Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos212.7212.712.0FalseNoneNoneFalseNoneFalse2552.40
278028188685Nonecode124Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90mm. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos99.6699.6618.0FalseNoneNoneFalseNoneFalse1793.880
278028288685Nonecode125Providing and fixing bright finished brass tower bolts(barrel type) with necessary screws etc. complete : 250x10mm, Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach409.59409.5918.0FalseNoneNoneFalseNoneFalse7372.620
278028388685Nonecode126Providing 12 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners with chicken mesh all around the wall with smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm258.88258.88360.19FalseNoneNoneFalseNoneFalse93245.98720
278028488685Nonecode127Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-incharge for works. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm301.42301.42501.82FalseNoneNoneFalseNoneFalse151258.58440
278028588685Nonecode128Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm100.88100.88710.56FalseNoneNoneFalseNoneFalse71681.29280
278028688685Nonecode129Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm373.13373.13255.38FalseNoneNoneFalseNoneFalse95289.93940
278028788685Nonecode130Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm2294.682294.6865.36FalseNoneNoneFalseNoneFalse149980.28480
278028888685Nonecode131Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm3488.23488.2310.8FalseNoneNoneFalseNoneFalse1084132.560
278028988685Nonecode132Providing and fixing 20mm thick gang saw water cut Lakared granite for cladding in CM 1:3 (1 cement : 3 coarse sand) proportion with a coat of rough plastering using CM 1:4 (1 cement : 4 fine sand), cut to required shape, pattern with paper joints, finished with cement mortar using white cement and colour pigments to match the colour of slab making through jointing with sealant, grooves in joints including cost of curing etc., complete including cost and conveyance of all materials, mortar, labour for all items of work, usage charges of machinery etc., complete as per specification. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm4251.474251.4710.07FalseNoneNoneFalseNoneFalse42812.30290
278029088685Nonecode133Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. Second floor complete with all lead and lift as per the direction of Engineer-In-Chargem326.94326.94100.7FalseNoneNoneFalseNoneFalse32922.8580
278029188685Nonecode134Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. - Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm735.32735.3222.35FalseNoneNoneFalseNoneFalse16434.4020
278029288685Nonecode135Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm1171.651171.6598.07FalseNoneNoneFalseNoneFalse114903.71550
278029388685Nonecode136Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm1959.221959.221.22FalseNoneNoneFalseNoneFalse2390.24840
278029488685Nonecode137Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm3013.133013.131.26FalseNoneNoneFalseNoneFalse3796.54380
278029588685Nonecode138Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer in- Charge. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeKg134.97134.97504.0FalseNoneNoneFalseNoneFalse68024.880
278029688685Nonecode139Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm48.6248.62710.56FalseNoneNoneFalseNoneFalse34547.42720
278029788685Nonecode140Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm96.0296.02710.56FalseNoneNoneFalseNoneFalse68227.97120
278029888685Nonecode141Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm252.8252.8255.38FalseNoneNoneFalseNoneFalse64560.0640
278029988685Nonecode142Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-incharge. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm109.39109.3929.28FalseNoneNoneFalseNoneFalse3202.93920
278030088685Nonecode143Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm49.8349.8318.9FalseNoneNoneFalseNoneFalse941.7870
278030188685Nonecode144Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete. up to Second Floor.Sqm4787.464787.469.6FalseNoneNoneFalseNoneFalse45959.6160
278030288685Nonecode145Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi -rigid, inorganic, non-combustible fibre glass wool insulation 50 mm thick, conforming to IS: 8183 and BS: 3958 Part 5. The insulation layer shall have facing (factory bonded on surface 1 of the fibre glass insulation layer), of black non-woven fibre glass tissue of nominal thickness 0.5 mm and nominal mass not less than 60 g/m2,made of randomly oriented glass fibres distributed in a binder by a wet-lay process including fixing 1.5 mm thick solid aluminum sheet backing using, 6 mm thick cement board including SS rivets, nuts, bolts, washers etc complete. up to Second floor.Sqm1898.451898.459.6FalseNoneNoneFalseNoneFalse18225.120
278030388685Nonecode146Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in- Charge. For payment, only the actual area of glass on face 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2. (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevent Item*).“(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 K etc. . The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. up to Second floor.Sqm2103.862103.869.6FalseNoneNoneFalseNoneFalse20197.0560
278030488685Nonecode147Providing and fixing of clay tiles for cladding tiles of size 230x75x10mm thick on 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) & jointed with Adhesive/cement slurry over rough plaster surface excluding cost of rough plastered surface and the surface is painted with red apex paint and black apex paint into the groves. The work includes cost of all materials, labour charges for all items of work, usage charges for equipment, etc., complete as per specification. up to Second floor.Sqm2253.352253.359.9FalseNoneNoneFalseNoneFalse22308.1650
278030588685Nonecode148Providing and laying in position Reinforced cement concrete for all Super structures ofbuilding , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - Third Floor Works complete with all lead and lift as per the direction of Engineer-In-ChargeCum7518.467518.46136.43FalseNoneNoneFalseNoneFalse1025743.49780
278030688685Nonecode149Providing, fixing and removing of formwork, Centering, shuttering and scaffolding for column. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum5262.935262.9312.24FalseNoneNoneFalseNoneFalse64418.26320
278030788685Nonecode150Providing, fixing and removing of formwork, Centering, shuttering and scaffolding (of Item No 32) for beam & lintels. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum4511.084511.0881.17FalseNoneNoneFalseNoneFalse366164.36360
278030888685Nonecode151Providing, fixing and removing of formwork, Centering, shuttering and scaffolding (of Item No 32) for slab & staircase. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum3759.233759.2343.02FalseNoneNoneFalseNoneFalse161722.07460
278030988685Nonecode152Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeKg111.82111.8215643.35FalseNoneNoneFalseNoneFalse1749239.3970
278031088685Nonecode153Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm1453.621453.62229.22FalseNoneNoneFalseNoneFalse333198.77640
278031188685Nonecode154Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Third floor complete with all lead and lift as per the direction of Engineer-In-Charge.Sqm3050.653050.652.88FalseNoneNoneFalseNoneFalse8785.8720
278031288685Nonecode155Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding for works. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeKg176.23176.23604.8FalseNoneNoneFalseNoneFalse106583.9040
278031388685Nonecode156Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) -Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm8799.58799.528.8FalseNoneNoneFalseNoneFalse253425.60
278031488685Nonecode157Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum109863.65109863.650.07FalseNoneNoneFalseNoneFalse7690.45550
278031588685Nonecode158Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. do- 30 mm thick both side commercial. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm3206.233206.232.52FalseNoneNoneFalseNoneFalse8079.69960
278031688685Nonecode159Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos132.48132.481.0FalseNoneNoneFalseNoneFalse132.480
278031788685Nonecode160Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos1069.551069.551.0FalseNoneNoneFalseNoneFalse1069.550
278031888685Nonecode161Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos1011.211011.211.0FalseNoneNoneFalseNoneFalse1011.210
278031988685Nonecode162Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos212.7212.72.0FalseNoneNoneFalseNoneFalse425.40
278032088685Nonecode163Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90mm. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos99.6699.663.0FalseNoneNoneFalseNoneFalse298.980
278032188685Nonecode164Providing and fixing bright finished brass tower bolts(barrel type) with necessary screws etc. complete : 250x10mm, Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach409.59409.593.0FalseNoneNoneFalseNoneFalse1228.770
278032288685Nonecode165Providing 12 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners with chicken mesh all around the wall with smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm258.88258.88360.19FalseNoneNoneFalseNoneFalse93245.98720
278032388685Nonecode166Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-incharge for works. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm301.42301.42308.56FalseNoneNoneFalseNoneFalse93006.15520
278032488685Nonecode167Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm100.88100.88668.75FalseNoneNoneFalseNoneFalse67463.50
278032588685Nonecode168Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm373.13373.13252.78FalseNoneNoneFalseNoneFalse94319.80140
278032688685Nonecode169Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm2294.682294.6864.25FalseNoneNoneFalseNoneFalse147433.190
278032788685Nonecode170Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm3488.23488.2310.8FalseNoneNoneFalseNoneFalse1084132.560
278032888685Nonecode171Providing and fixing 20mm thick gang saw water cut Lakared granite for cladding in CM 1:3 (1 cement : 3 coarse sand) proportion with a coat of rough plastering using CM 1:4 (1 cement : 4 fine sand), cut to required shape, pattern with paper joints, finished with cement mortar using white cement and colour pigments to match the colour of slab making through jointing with sealant, grooves in joints including cost of curing etc., complete including cost and conveyance of all materials, mortar, labour for all items of work, usage charges of machinery etc., complete as per specification. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm4251.474251.4710.37FalseNoneNoneFalseNoneFalse44087.74390
278032988685Nonecode172Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.Third floor complete with all lead and lift as per the direction of Engineer-In-Chargem326.94326.94104.78FalseNoneNoneFalseNoneFalse34256.77320
278033088685Nonecode173Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer in- Charge. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeKg134.91134.91552.0FalseNoneNoneFalseNoneFalse74470.320
278033188685Nonecode174Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm48.6248.62668.75FalseNoneNoneFalseNoneFalse32514.6250
278033288685Nonecode175Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm96.0296.02668.75FalseNoneNoneFalseNoneFalse64213.3750
278033388685Nonecode176Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm252.8252.8252.78FalseNoneNoneFalseNoneFalse63902.7840
278033488685Nonecode177Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-incharge. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm109.39109.3932.7FalseNoneNoneFalseNoneFalse3577.0530
278033588685Nonecode178Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm49.8349.832.52FalseNoneNoneFalseNoneFalse125.57160
278033688685Nonecode179Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete up to First floorSqm4787.464787.469.6FalseNoneNoneFalseNoneFalse45959.6160
278033788685Nonecode180Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi -rigid, inorganic, non-combustible fibre glass wool insulation 50 mm thick, conforming to IS: 8183 and BS: 3958 Part 5. The insulation layer shall have facing (factory bonded on surface 1 of the fibre glass insulation layer), of black non-woven fibre glass tissue of nominal thickness 0.5 mm and nominal mass not less than 60 g/m2,made of randomly oriented glass fibres distributed in a binder by a wet-lay process including fixing 1.5 mm thick solid aluminum sheet backing using, 6 mm thick cement board including SS rivets, nuts, bolts, washers etc complete. up to First FloorSqm1898.451898.459.6FalseNoneNoneFalseNoneFalse18225.120
278033888685Nonecode181Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in- Charge. For payment, only the actual area of glass on face 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2. (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevent Item*).“(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 K etc. . The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. Up to first floorSqm2103.862103.869.6FalseNoneNoneFalseNoneFalse20197.0560
278033988685Nonecode182Providing and fixing of clay tiles for cladding tiles of size 230x75x10mm thick on 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) & jointed with Adhesive/cement slurry over rough plaster surface excluding cost of rough plastered surface and the surface is painted with red apex paint and black apex paint into the groves. The work includes cost of all materials, labour charges for all items of work, usage charges for equipment, etc., complete as per specification.Up to first floorSqm2253.352253.359.9FalseNoneNoneFalseNoneFalse22308.1650
278034088685Nonecode183Providing and laying in position Reinforced cement concrete for all Super structures ofbuilding , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - Fourth Floor Works complete with all lead and lift as per the direction of Engineer-In-ChargeCum7518.467518.4636.38FalseNoneNoneFalseNoneFalse273521.57480
278034188685Nonecode184Providing, fixing and removing of formwork, Centering, shuttering and scaffolding for column. Fourth Floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum5262.935262.9311.16FalseNoneNoneFalseNoneFalse58734.29880
278034288685Nonecode185Providing, fixing and removing of formwork, Centering, shuttering and scaffolding (of Item No 32) for beam & lintels. Fourth Floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum4511.084511.0812.28FalseNoneNoneFalseNoneFalse55396.06240
278034388685Nonecode186Providing, fixing and removing of formwork, Centering, shuttering and scaffolding (of Item No 32) for slab & staircase. Fourth Floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum3759.233759.2312.95FalseNoneNoneFalseNoneFalse48682.02850
278034488685Nonecode187Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately). Fourth Floor complete with all lead and lift as per the direction of Engineer-In-ChargeKg111.82111.824008.19FalseNoneNoneFalseNoneFalse448195.80580
278034588685Nonecode188Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications for works. Fourth Floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm1453.621453.62173.03FalseNoneNoneFalseNoneFalse251519.86860
278034688685Nonecode189Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm1142.481142.4859.28FalseNoneNoneFalseNoneFalse67726.21440
278034788685Nonecode190Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. -Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum2451.462451.464.5FalseNoneNoneFalseNoneFalse11031.570
278034888685Nonecode191Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding for works. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeKg176.23176.23223.65FalseNoneNoneFalseNoneFalse39413.83950
278034988685Nonecode192Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) -Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm8799.58799.58.4FalseNoneNoneFalseNoneFalse73915.80
278035088685Nonecode193Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm5919.05919.02.25FalseNoneNoneFalseNoneFalse13317.750
278035188685Nonecode194Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum109863.65109863.650.26FalseNoneNoneFalseNoneFalse28564.5490
278035288685Nonecode195Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. do- 30 mm thick both side commercial. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm3206.233206.2312.6FalseNoneNoneFalseNoneFalse40398.4980
278035388685Nonecode196Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. Fourth floor.m577.32577.3247.88FalseNoneNoneFalseNoneFalse27642.08160
278035488685Nonecode197Providing and fixing factory made 100% carpenter friendly ready to use single solid plain wood polymer composite (WPC) flush shutter of 30mm thick which is anti terminate and having high water observation property. The cost include cost of material, transportation, labour and fixing charges. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm4227.164227.166.3FalseNoneNoneFalseNoneFalse26631.1080
278035588685Nonecode198Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos132.48132.486.0FalseNoneNoneFalseNoneFalse794.880
278035688685Nonecode199Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos1069.551069.556.0FalseNoneNoneFalseNoneFalse6417.30
278035788685Nonecode200Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos1011.211011.216.0FalseNoneNoneFalseNoneFalse6067.260
278035888685Nonecode201Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos212.7212.712.0FalseNoneNoneFalseNoneFalse2552.40
278035988685Nonecode202Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90mm. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos2.92.918.0FalseNoneNoneFalseNoneFalse52.20
278036088685Nonecode203Providing and fixing bright finished brass tower bolts(barrel type) with necessary screws etc. complete : 250x10mm, Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach409.59409.5918.0FalseNoneNoneFalseNoneFalse7372.620
278036188685Nonecode204Providing 12 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners with chicken mesh all around the wall with smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm258.88258.8867.17FalseNoneNoneFalseNoneFalse17388.96960
278036288685Nonecode205Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-incharge for works. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm301.42301.42419.37FalseNoneNoneFalseNoneFalse126406.50540
278036388685Nonecode206Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm100.88100.88329.91FalseNoneNoneFalseNoneFalse33281.32080
278036488685Nonecode207Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm373.13373.13145.85FalseNoneNoneFalseNoneFalse54421.01050
278036588685Nonecode208Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm2294.682294.6850.6FalseNoneNoneFalseNoneFalse116110.8080
278036688685Nonecode209Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm3488.23488.254.63FalseNoneNoneFalseNoneFalse190560.3660
278036788685Nonecode210Providing and fixing 20mm thick gang saw water cut Lakared granite for cladding in CM 1:3 (1 cement : 3 coarse sand) proportion with a coat of rough plastering using CM 1:4 (1 cement : 4 fine sand), cut to required shape, pattern with paper joints, finished with cement mortar using white cement and colour pigments to match the colour of slab making through jointing with sealant, grooves in joints including cost of curing etc., complete including cost and conveyance of all materials, mortar, labour for all items of work, usage charges of machinery etc., complete as per specification. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm4251.474251.473.83FalseNoneNoneFalseNoneFalse16283.13010
278036888685Nonecode211Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.Fourth floor complete with all lead and lift as per the direction of Engineer-In-Chargem326.94326.9438.3FalseNoneNoneFalseNoneFalse12521.8020
278036988685Nonecode212Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. - Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm735.32735.3215.6FalseNoneNoneFalseNoneFalse11470.9920
278037088685Nonecode213Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm1171.651171.65111.32FalseNoneNoneFalseNoneFalse130428.0780
278037188685Nonecode214Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm1959.221959.221.22FalseNoneNoneFalseNoneFalse2390.24840
278037288685Nonecode215Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm4193.134193.131.26FalseNoneNoneFalseNoneFalse5283.34380
278037388685Nonecode216Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer in- Charge. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeKg134.91134.91288.0FalseNoneNoneFalseNoneFalse38854.080
278037488685Nonecode217Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. . Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm48.6248.62329.91FalseNoneNoneFalseNoneFalse16040.22420
278037588685Nonecode218Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm96.0296.02329.91FalseNoneNoneFalseNoneFalse31677.95820
278037688685Nonecode219Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm252.8252.8145.85FalseNoneNoneFalseNoneFalse36870.880
278037788685Nonecode220Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-incharge. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm109.39109.3910.65FalseNoneNoneFalseNoneFalse1165.00350
278037888685Nonecode221Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm49.8349.8318.9FalseNoneNoneFalseNoneFalse941.7870
278037988685Nonecode222Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete. up to Fourth Floor.Sqm4787.464787.4619.2FalseNoneNoneFalseNoneFalse91919.2320
278038088685Nonecode223Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi -rigid, inorganic, non-combustible fibre glass wool insulation 50 mm thick, conforming to IS: 8183 and BS: 3958 Part 5. The insulation layer shall have facing (factory bonded on surface 1 of the fibre glass insulation layer), of black non-woven fibre glass tissue of nominal thickness 0.5 mm and nominal mass not less than 60 g/m2,made of randomly oriented glass fibres distributed in a binder by a wet-lay process including fixing 1.5 mm thick solid aluminum sheet backing using, 6 mm thick cement board including SS rivets, nuts, bolts, washers etc complete. up to First floor.Sqm1898.451898.4519.2FalseNoneNoneFalseNoneFalse36450.240
278038188685Nonecode224Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in- Charge. For payment, only the actual area of glass on face 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2. (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevent Item*).“(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 K etc. . The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. up to Fourth floor.Sqm2103.862103.8619.2FalseNoneNoneFalseNoneFalse40394.1120
278038288685Nonecode225Providing and fixing of clay tiles for cladding tiles of size 230x75x10mm thick on 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) & jointed with Adhesive/cement slurry over rough plaster surface excluding cost of rough plastered surface and the surface is painted with red apex paint and black apex paint into the groves. The work includes cost of all materials, labour charges for all items of work, usage charges for equipment, etc., complete as per specification. up to Fourth floor.Sqm2253.352253.353.3FalseNoneNoneFalseNoneFalse7436.0550
278038388685Nonecode226Providing and laying in position Reinforced cement concrete for all Super structures ofbuilding , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - Terrace Floor Works complete with all lead and lift as per the direction of Engineer-In-ChargeCum7518.467518.4622.75FalseNoneNoneFalseNoneFalse171044.9650
278038488685Nonecode227Providing, fixing and removing of formwork, Centering, shuttering and scaffolding for column. Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum5262.935262.936.03FalseNoneNoneFalseNoneFalse31735.46790
278038588685Nonecode228Providing, fixing and removing of formwork, Centering, shuttering and scaffolding (of Item No 32) for beam & lintels. Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum4511.084511.087.46FalseNoneNoneFalseNoneFalse33652.65680
278038688685Nonecode229Providing, fixing and removing of formwork, Centering, shuttering and scaffolding (of Item No 32) for slab & staircase. Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum3759.233759.239.25FalseNoneNoneFalseNoneFalse34772.87750
278038788685Nonecode230Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeKg100.88100.882568.21FalseNoneNoneFalseNoneFalse259081.02480
278038888685Nonecode231Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm159.22159.22165.92FalseNoneNoneFalseNoneFalse26417.78240
278038988685Nonecode232Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding for works Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeKg159.22159.22138.6FalseNoneNoneFalseNoneFalse22067.8920
278039088685Nonecode233Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) -Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm8799.58799.56.6FalseNoneNoneFalseNoneFalse58076.70
278039188685Nonecode234Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum109863.55109863.550.07FalseNoneNoneFalseNoneFalse7690.44850
278039288685Nonecode235Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. do- 30 mm thick both side commercial. Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm3206.233206.232.52FalseNoneNoneFalseNoneFalse8079.69960
278039388685Nonecode236Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos132.48132.481.0FalseNoneNoneFalseNoneFalse132.480
278039488685Nonecode237Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos1069.551069.551.0FalseNoneNoneFalseNoneFalse1069.550
278039588685Nonecode238Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos1011.211011.211.0FalseNoneNoneFalseNoneFalse1011.210
278039688685Nonecode239Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos212.7212.72.0FalseNoneNoneFalseNoneFalse425.40
278039788685Nonecode240Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90mm Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos99.6699.663.0FalseNoneNoneFalseNoneFalse298.980
278039888685Nonecode241Providing and fixing bright finished brass tower bolts(barrel type) with necessary screws etc. complete : 250x10mm, Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach409.59409.593.0FalseNoneNoneFalseNoneFalse1228.770
278039988685Nonecode242Providing 12 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners with chicken mesh all around the wall with smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm258.88258.8856.83FalseNoneNoneFalseNoneFalse14712.15040
278040088685Nonecode243Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-incharge for works Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm301.42301.42147.83FalseNoneNoneFalseNoneFalse44558.91860
278040188685Nonecode244Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm100.88100.88204.66FalseNoneNoneFalseNoneFalse20646.10080
278040288685Nonecode245Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm373.13373.13378.65FalseNoneNoneFalseNoneFalse141285.67450
278040388685Nonecode246Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer in- Charge. Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeKg134.91134.91990.0FalseNoneNoneFalseNoneFalse133560.90
278040488685Nonecode247Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Terrace floorcomplete with all lead and lift as per the direction of Engineer-In-ChargeSqm48.6248.62204.66FalseNoneNoneFalseNoneFalse9950.56920
278040588685Nonecode248Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm96.0296.02204.66FalseNoneNoneFalseNoneFalse19651.45320
278040688685Nonecode249Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm252.8252.8378.65FalseNoneNoneFalseNoneFalse95722.720
278040788685Nonecode250Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-incharge. Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm109.39109.397.15FalseNoneNoneFalseNoneFalse782.13850
278040888685Nonecode251Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge. Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm49.8349.832.52FalseNoneNoneFalseNoneFalse125.57160
278040988685Nonecode252Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace / Chajjas / Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction ofthe Engineer In charge. - Terrace floorcomplete with all lead and lift as per the direction of Engineer-In-ChargeSqm950.75950.75345.6FalseNoneNoneFalseNoneFalse328579.20
278041088685Nonecode253Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) greater than 78, solar reflection greater than 0.70 and initial emittance greater than 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner as per direction of incharge.-Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm1360.781360.78234.0FalseNoneNoneFalseNoneFalse318422.520
17086724940001NoneNoneBuildingsPLUMBING WORKS1541410.12
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
278041188686Nonecode01Constructing brick masonry chamber of internal dimension 600x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. complete with all lead and lift as per the direction of Engineer-In-ChargeEach5316.165316.168.0FalseNoneNoneFalseNoneFalse42529.280
278041288686Nonecode02Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.. complete with all lead and lift as per the direction of Engineer-In-ChargeEach6049.056049.052.0FalseNoneNoneFalseNoneFalse12098.10
278041388686Nonecode03Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.In all kinds of soils. Depth upto 1.50m complete with all lead and lift as per the direction of Engineer-In-ChargeCum450.91450.9116.2FalseNoneNoneFalseNoneFalse7304.7420
278041488686Nonecode04Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 complete with all lead and lift as per the direction of Engineer-In-ChargeMtr478.87478.8765.0FalseNoneNoneFalseNoneFalse31126.550
278041588686Nonecode05Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 140mm dia., 6 kg/sqcm & class 3 complete with all lead and lift as per the direction of Engineer-In-ChargeMtr689.13689.1365.0FalseNoneNoneFalseNoneFalse44793.450
278041688686Nonecode06Providing and placing on terrace (at all floor levels), polyethylene water storage tanks, IS:127001 marked, with cover and suitable locking arrangements, making necessary holes for inlet, outlet and over flow pipes but without fittings and the base support for tank. complete with all lead and lift as per the direction of Engineer-In-ChargeLtr9.729.724000.0FalseNoneNoneFalseNoneFalse38880.00
278041788686Nonecode07Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 20 mm Dia (Ground Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeMtr261.31261.3140.0FalseNoneNoneFalseNoneFalse10452.40
278041888686Nonecode08Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 20 mm Dia (First Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeMtr261.31261.3135.0FalseNoneNoneFalseNoneFalse9145.850
278041988686Nonecode09Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 20 mm Dia (Second Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeMtr261.31261.3130.0FalseNoneNoneFalseNoneFalse7839.30
278042088686Nonecode10Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 20 mm Dia (Third Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeMtr261.31261.3125.0FalseNoneNoneFalseNoneFalse6532.750
278042188686Nonecode11Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 20 mm Dia (Fourth Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeMtr363.4363.420.0FalseNoneNoneFalseNoneFalse7268.00
278042288686Nonecode12Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm Dia (Ground Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeMtr363.4363.440.0FalseNoneNoneFalseNoneFalse14536.00
278042388686Nonecode13Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm Dia (First Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeMtr363.4363.435.0FalseNoneNoneFalseNoneFalse12719.00
278042488686Nonecode14Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm Dia (Second Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeMtr363.4363.430.0FalseNoneNoneFalseNoneFalse10902.00
278042588686Nonecode15Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm Dia (Third Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeMtr363.4363.425.0FalseNoneNoneFalseNoneFalse9085.00
278042688686Nonecode16Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm Dia (Fourth Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeMtr435.11435.1120.0FalseNoneNoneFalseNoneFalse8702.20
278042788686Nonecode17Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 32 mm Dia (Ground Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeMtr435.11435.1140.0FalseNoneNoneFalseNoneFalse17404.40
278042888686Nonecode18Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 32 mm Dia (First Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeMtr435.11435.1135.0FalseNoneNoneFalseNoneFalse15228.850
278042988686Nonecode19Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 32 mm Dia (Second Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeMtr435.11435.1130.0FalseNoneNoneFalseNoneFalse13053.30
278043088686Nonecode20Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 32 mm Dia (Third Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeMtr435.11435.1125.0FalseNoneNoneFalseNoneFalse10877.750
278043188686Nonecode21Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 32 mm Dia (Fourth Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeMtr853.21853.2120.0FalseNoneNoneFalseNoneFalse17064.20
278043288686Nonecode22Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm Dia (Ground Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeMtr853.21853.2140.0FalseNoneNoneFalseNoneFalse34128.40
278043388686Nonecode23Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm Dia (First Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeMtr853.21853.2135.0FalseNoneNoneFalseNoneFalse29862.350
278043488686Nonecode24Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm Dia (Second Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeMtr853.21853.2130.0FalseNoneNoneFalseNoneFalse25596.30
278043588686Nonecode25Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm Dia (Third Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeMtr853.21853.2125.0FalseNoneNoneFalseNoneFalse21330.250
278043688686Nonecode26Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm Dia (Fourth Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeMtr396.22396.2220.0FalseNoneNoneFalseNoneFalse7924.40
278043788686Nonecode27Providing and fixing in position brass bib cock of approved quality 15mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. (Ground Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeEach396.22396.226.0FalseNoneNoneFalseNoneFalse2377.320
278043888686Nonecode28Providing and fixing in position brass bib cock of approved quality 15mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. (First Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeEach396.22396.2210.0FalseNoneNoneFalseNoneFalse3962.20
278043988686Nonecode29Providing and fixing in position brass bib cock of approved quality 15mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. (Second Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeEach396.22396.2210.0FalseNoneNoneFalseNoneFalse3962.20
278044088686Nonecode30Providing and fixing in position brass bib cock of approved quality 15mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. (Third Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeEach396.22396.2210.0FalseNoneNoneFalseNoneFalse3962.20
278044188686Nonecode31Providing and fixing in position brass bib cock of approved quality 20mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. (Ground Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeEach419.31419.316.0FalseNoneNoneFalseNoneFalse2515.860
278044288686Nonecode32Providing and fixing in position brass bib cock of approved quality 20mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. (First Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeEach419.31419.3110.0FalseNoneNoneFalseNoneFalse4193.10
278044388686Nonecode33Providing and fixing in position brass bib cock of approved quality 20mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. (Second Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeEach419.31419.3110.0FalseNoneNoneFalseNoneFalse4193.10
278044488686Nonecode34Providing and fixing in position brass bib cock of approved quality 20mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. (Third Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeEach419.31419.3110.0FalseNoneNoneFalseNoneFalse4193.10
278044588686Nonecode35Providing and fixing ball valve (brass) of approved quality, High or low-pressure, with plastic floats complete : 20 mm Dia (Ground Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeEach437.54437.545.0FalseNoneNoneFalseNoneFalse2187.70
278044688686Nonecode36Providing and fixing ball valve (brass) of approved quality, High or low-pressure, with plastic floats complete : 20 mm Dia (First Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeEach437.54437.545.0FalseNoneNoneFalseNoneFalse2187.70
278044788686Nonecode37Providing and fixing ball valve (brass) of approved quality, High or low-pressure, with plastic floats complete : 20 mm Dia (Second Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeEach437.54437.545.0FalseNoneNoneFalseNoneFalse2187.70
278044888686Nonecode38Providing and fixing ball valve (brass) of approved quality, High or low-pressure, with plastic floats complete : 20 mm Dia (Third Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeEach437.54437.545.0FalseNoneNoneFalseNoneFalse2187.70
278044988686Nonecode39Providing and fixing ball valve (brass) of approved quality, High or low-pressure, with plastic floats complete : 20 mm Dia (Fourth Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeEach466.71466.715.0FalseNoneNoneFalseNoneFalse2333.550
278045088686Nonecode40Providing and fixing ball valve (brass) of approved quality, High or low-pressure, with plastic floats complete : 25 mm Dia (Ground Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeEach466.71466.712.0FalseNoneNoneFalseNoneFalse933.420
278045188686Nonecode41Providing and fixing ball valve (brass) of approved quality, High or low-pressure, with plastic floats complete : 25 mm Dia (First Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeEach466.71466.712.0FalseNoneNoneFalseNoneFalse933.420
278045288686Nonecode42Providing and fixing ball valve (brass) of approved quality, High or low-pressure, with plastic floats complete : 25 mm Dia (Second Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeEach466.71466.712.0FalseNoneNoneFalseNoneFalse933.420
278045388686Nonecode43Providing and fixing ball valve (brass) of approved quality, High or low-pressure, with plastic floats complete : 25 mm Dia (Third Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeEach466.71466.712.0FalseNoneNoneFalseNoneFalse933.420
278045488686Nonecode44Providing and fixing ball valve (brass) of approved quality, High or low-pressure, with plastic floats complete : 25 mm Dia (Fourth Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeEach466.71466.712.0FalseNoneNoneFalseNoneFalse933.420
278045588686Nonecode45Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps Ground Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach3073.753073.752.0FalseNoneNoneFalseNoneFalse6147.50
278045688686Nonecode46Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps First Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach3073.753073.755.0FalseNoneNoneFalseNoneFalse15368.750
278045788686Nonecode47Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps Second Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach3073.753073.755.0FalseNoneNoneFalseNoneFalse15368.750
278045888686Nonecode48Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps Fourth Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach3073.753073.754.0FalseNoneNoneFalseNoneFalse12295.00
278045988686Nonecode49Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. Ground Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach461.85461.853.0FalseNoneNoneFalseNoneFalse1385.550
278046088686Nonecode50Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. First Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach461.85461.853.0FalseNoneNoneFalseNoneFalse1385.550
278046188686Nonecode51Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. Second Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach461.85461.853.0FalseNoneNoneFalseNoneFalse1385.550
278046288686Nonecode52Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. Third Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach461.85461.853.0FalseNoneNoneFalseNoneFalse1385.550
278046388686Nonecode53Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm Ground Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach1056.181056.182.0FalseNoneNoneFalseNoneFalse2112.360
278046488686Nonecode54Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm First Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach1056.181056.183.0FalseNoneNoneFalseNoneFalse3168.540
278046588686Nonecode55Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm Second Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach1056.181056.183.0FalseNoneNoneFalseNoneFalse3168.540
278046688686Nonecode56Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm Fourth Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach1056.181056.182.0FalseNoneNoneFalseNoneFalse2112.360
278046788686Nonecode57Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests Ground Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach5160.595160.591.0FalseNoneNoneFalseNoneFalse5160.590
278046888686Nonecode58Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests First Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach5160.595160.592.0FalseNoneNoneFalseNoneFalse10321.180
278046988686Nonecode59Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests Second Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach5160.595160.592.0FalseNoneNoneFalseNoneFalse10321.180
278047088686Nonecode60Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests Fourth Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach6083.086083.082.0FalseNoneNoneFalseNoneFalse12166.160
278047188686Nonecode61Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid Ground Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach6083.086083.081.0FalseNoneNoneFalseNoneFalse6083.080
278047288686Nonecode62Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid First Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach6083.086083.082.0FalseNoneNoneFalseNoneFalse12166.160
278047388686Nonecode63Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid Second Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach6083.086083.082.0FalseNoneNoneFalseNoneFalse12166.160
278047488686Nonecode64Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid Third Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach6083.086083.082.0FalseNoneNoneFalseNoneFalse12166.160
278047588686Nonecode65Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern as per the directions and instructions of engineer in charge. Ground Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach4297.654297.652.0FalseNoneNoneFalseNoneFalse8595.30
278047688686Nonecode66Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern as per the directions and instructions of engineer in charge. First Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach4297.654297.652.0FalseNoneNoneFalseNoneFalse8595.30
278047788686Nonecode67Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern as per the directions and instructions of engineer in charge. Second Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach4297.654297.652.0FalseNoneNoneFalseNoneFalse8595.30
278047888686Nonecode68Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern as per the directions and instructions of engineer in charge. Third Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach4297.654297.652.0FalseNoneNoneFalseNoneFalse8595.30
278047988686Nonecode69Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors: * 100mm inlet and 100mm outlet * Sand Cast Iron S&S as per IS:1729 Ground Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach1172.861172.864.0FalseNoneNoneFalseNoneFalse4691.440
278048088686Nonecode70Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors: * 100mm inlet and 100mm outlet * Sand Cast Iron S&S as per IS:1729 First Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach1172.861172.868.0FalseNoneNoneFalseNoneFalse9382.880
278048188686Nonecode71Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors: * 100mm inlet and 100mm outlet * Sand Cast Iron S&S as per IS:1729 Second Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach1172.861172.868.0FalseNoneNoneFalseNoneFalse9382.880
278048288686Nonecode72Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors: * 100mm inlet and 100mm outlet * Sand Cast Iron S&S as per IS:1729 Third Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach1172.861172.868.0FalseNoneNoneFalseNoneFalse9382.880
278048388686Nonecode73Providing and fixing on wall surface unplasticised Rigid rain water pipes confirming to IS:13592 Type A, including jointing with seal ring confirming to IS:5382, leaving 10mm gap for thermal expansion, (i) Single socketed pipes 100mm diameter. Ground floor to First floor complete with all lead and lift as per the direction of Engineer-In-ChargeMtr307.5307.5200.0FalseNoneNoneFalseNoneFalse61500.00
278048488686Nonecode74Providing and fixing on wall surface unplasticised Rigid rain water pipes confirming to IS:13592 Type A, including jointing with seal ring confirming to IS:5382, leaving 10mm gap for thermal expansion, (i) Single socketed pipes 100mm diameter. First floor to second floor complete with all lead and lift as per the direction of Engineer-In-ChargeMtr307.5307.5100.0FalseNoneNoneFalseNoneFalse30750.00
278048588686Nonecode75Providing and fixing on wall surface unplasticised Rigid rain water pipes confirming to IS:13592 Type A, including jointing with seal ring confirming to IS:5382, leaving 10mm gap for thermal expansion, (i) Single socketed pipes 100mm diameter. Second floor to Third complete with all lead and lift as per the direction of Engineer-In-ChargeMtr307.5307.5100.0FalseNoneNoneFalseNoneFalse30750.00
278048688686Nonecode76Providing and fixing on wall surface unplasticised Rigid rain water pipes confirming to IS:13592 Type A, including jointing with seal ring confirming to IS:5382, leaving 10mm gap for thermal expansion, (i) Single socketed pipes 100mm diameter. Third floor to terrace complete with all lead and lift as per the direction of Engineer-In-ChargeMtr307.5307.5100.0FalseNoneNoneFalseNoneFalse30750.00
278048788686Nonecode77Cutting holes upto 30x30cm in walls including making good the same: with common burnt clay F.P.S (non modular) bricks. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach323.3323.310.0FalseNoneNoneFalseNoneFalse3233.00
278048888686Nonecode78Cutting holes upto 30x30cm in walls including making good the same: with common burnt clay F.P.S (non modular) bricks. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach323.3323.310.0FalseNoneNoneFalseNoneFalse3233.00
278048988686Nonecode79Cutting holes upto 30x30cm in walls including making good the same: with common burnt clay F.P.S (non modular) bricks. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach323.3323.310.0FalseNoneNoneFalseNoneFalse3233.00
278049088686Nonecode80Cutting holes upto 30x30cm in walls including making good the same: with common burnt clay F.P.S (non modular) bricks. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach323.3323.340.0FalseNoneNoneFalseNoneFalse12932.00
278049188686Nonecode81Cutting holes upto 15x15cm in RCC floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc, with cement concrete 1:2:4 (1 cement: 2 Coarse sand: 4 graded stone aggregate 20mm nominal size), including finishing complete so as to make it leak proof. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeMtr295.34295.345.0FalseNoneNoneFalseNoneFalse1476.70
278049288686Nonecode82Cutting holes upto 15x15cm in RCC floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc, with cement concrete 1:2:4 (1 cement: 2 Coarse sand: 4 graded stone aggregate 20mm nominal size), including finishing complete so as to make it leak proof. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeMtr295.34295.345.0FalseNoneNoneFalseNoneFalse1476.70
278049388686Nonecode83Cutting holes upto 15x15cm in RCC floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc, with cement concrete 1:2:4 (1 cement: 2 Coarse sand: 4 graded stone aggregate 20mm nominal size), including finishing complete so as to make it leak proof. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeMtr295.34295.345.0FalseNoneNoneFalseNoneFalse1476.70
278049488686Nonecode84Cutting holes upto 15x15cm in RCC floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc, with cement concrete 1:2:4 (1 cement: 2 Coarse sand: 4 graded stone aggregate 20mm nominal size), including finishing complete so as to make it leak proof. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeMtr295.34295.342.0FalseNoneNoneFalseNoneFalse590.680
278049588686Nonecode85Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 15 mm nominal bore Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos399.87399.872.0FalseNoneNoneFalseNoneFalse799.740
278049688686Nonecode86Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 15 mm nominal bore First floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach399.87399.872.0FalseNoneNoneFalseNoneFalse799.740
278049788686Nonecode87Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 15 mm nominal bore Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos182.31182.312.0FalseNoneNoneFalseNoneFalse364.620
278049888686Nonecode88Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 15 mm nominal bore Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach199.33199.332.0FalseNoneNoneFalseNoneFalse398.660
278049988686Nonecode89Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach5644.325644.322.0FalseNoneNoneFalseNoneFalse11288.640
278050088686Nonecode90Providing and fixing of universal clamp of size 2.5 made out of mild steel including fixing with the drop in anchor and taper nut sleeve anchor complete including bolting, cost of labour and material GF to Terrace complete with all lead and lift as per the direction of Engineer-In-ChargeEach53.0453.04300.0FalseNoneNoneFalseNoneFalse15912.00
278050188686Nonecode91Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete )Mtr678.19678.19200.0FalseNoneNoneFalseNoneFalse135638.00
278050288686Nonecode92Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty.Mtr2349.372349.37200.0FalseNoneNoneFalseNoneFalse469874.00
278050388686Nonecode93Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendmentsEach182.31182.311.0FalseNoneNoneFalseNoneFalse182.310
278050488686Nonecode94Providing and laying at site of work MS casing caps as per IS 1239 (partII) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in chargeEach199.33199.331.0FalseNoneNoneFalseNoneFalse199.330
17086724940001NoneNoneBuildingsELECTRICAL WORKS10983433.98
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
278050588687Nonecode01Supply Erection testing and commissioning of of 11KV load break switch with 4 wire-(3 CT with nuetral) metering cubicle and connecting accessories suitable for outdoor type complete as per latest IS standards and ESCOM approved technical specification metering cubicle with LBSNo340580.92340580.921.0FalseNoneNoneFalseNoneFalse340580.920
278050688687Nonecode02Supply, erection, testing and commissioning of ...500.. KVA 5 Star rated Aluminium/Copper wound Distribution Transformer 11KV/433V with Off Load Tap Switch, Buchholtz relay winding temperature indicator, oil temperature indicator, marshalling box with wiring, oil level indicator with + 5% to -10% Steps of 2.5%, HT and LT Cable Entry Box Type, stacked core with oil as per IS:1180(Part-1):2014 with all standard accessories as per latest IS standard No:2026/1977 and IS:335, technical specification & ESCOM 500 KVA - Aluminium WoundNo1416000.01416000.01.0FalseNoneNoneFalseNoneFalse1416000.00
278050788687Nonecode03HT Cable Group A Supplying & Laying of High Tension 11kVCable Dry Curing & Dry Cooling With true triple Extrusion , Simltaneously Through a Single Common head 3Core under Ground XLPE ( E ) Cable having stranded Compact Circular Aluminium Conductor , Screened insulated , insulation screened with extruded semiconducting compound in combination with copper tape core laid up extruded inner shelthed of GI flat strip armoured and over all PVC Sheathed with Specified IS 7098 / 11 /85 with latest amendments & confirming to the GTP of Group -AMtr1628.41628.4140.0FalseNoneNoneFalseNoneFalse227976.00
278050888687Nonecode04Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 3.5 core 185 sqmm.Mtr1056.11056.1100.0FalseNoneNoneFalseNoneFalse105610.00
278050988687Nonecode05Supply and fixing regular MCCB distribution panel confirming IS 8828, on wall/wood board/flush mounting using clamps,bolts,nuts etc with provision for fixing suitable type capacity MCCB as an incomer for 3pahse double door necessary bus bar completely wired to use on 440 volts 3 phase 4 wire powder coated paiting etc complete with a provision for fixing of single/three phase suitable capacity MCCb/MCB's as outgoings confirming to IEC 60898 700 A MCCB.No51358.3251358.321.0FalseNoneNoneFalseNoneFalse51358.320
278051088687Nonecode06Supplying heavy gauge PVC conduit pipe ……dia…..mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall /stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 19/20mm dia 2mm thickMtr80.2480.24950.0FalseNoneNoneFalseNoneFalse76228.00
278051188687Nonecode07Supplying heavy gauge PVC conduit pipe ……dia…..mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall /stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25mm dia 2mm thickMtr94.494.41800.0FalseNoneNoneFalseNoneFalse169920.00
278051288687Nonecode08Supplying PVC/GI flexible conduit pipe….mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely. 20mmMtr29.529.5500.0FalseNoneNoneFalseNoneFalse14750.00
278051388687Nonecode09Supplying PVC/GI flexible conduit pipe….mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely. 25mmMtr123.9123.9500.0FalseNoneNoneFalseNoneFalse61950.00
278051488687Nonecode10Supplying heavy gauge PVC conduit pipe …….dia .......mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. . 32mm dia 2.5mm thickMtr108.56108.56400.0FalseNoneNoneFalseNoneFalse43424.00
278051588687Nonecode11Supplying push button operated direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet or iron clad enclosure and fixing the same to suitable capacity wires for 400/440 volts 3 phase motor/single phase motor upto 5 HPEach1758.21758.22.0FalseNoneNoneFalseNoneFalse3516.40
278051688687Nonecode12Supplying fully automatic star-delta starter unit push button type with suitable wires, 3 contactors, one adjustable thermal timer mounted on a common base plate held in steel enclosure for use on 400/440 volts 3 phase and wired after fixing to the existing wooden board for motor.Each7552.07552.02.0FalseNoneNoneFalseNoneFalse15104.00
278051788687Nonecode13Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (Icu = Ics) 400 AEach30680.030680.03.0FalseNoneNoneFalseNoneFalse92040.00
278051888687Nonecode14Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 5-32 Amps SPEach617.14617.1470.0FalseNoneNoneFalseNoneFalse43199.80
278051988687Nonecode15Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 Amps SPEach856.68856.6820.0FalseNoneNoneFalseNoneFalse17133.60
278052088687Nonecode16Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. 4 Way TP & NEach3602.543602.548.0FalseNoneNoneFalseNoneFalse28820.320
278052188687Nonecode17Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. 6Way TP &NEach4407.34407.38.0FalseNoneNoneFalseNoneFalse35258.40
278052288687Nonecode18Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board.Each2950.02950.020.0FalseNoneNoneFalseNoneFalse59000.00
278052388687Nonecode19Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB ). The entire plug and socket shall be mounted in a thermoplastic / powder coated metal box & wired Completely. 20AmpsEach1030.141030.1425.0FalseNoneNoneFalseNoneFalse25753.50
278052488687Nonecode20Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB ). The entire plug and socket shall be mounted in a thermoplastic / powder coated metal box & wired Completely. 30AmpsEach1810.121810.1260.0FalseNoneNoneFalseNoneFalse108607.20
278052588687Nonecode21Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2x1.5 sqmm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch boxEach324.5324.5500.0FalseNoneNoneFalseNoneFalse162250.00
278052688687Nonecode22Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2x1.5 sqmm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to outlet via switch boxEach425.98425.98200.0FalseNoneNoneFalseNoneFalse85196.00
278052788687Nonecode23Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2x1.5 sqmm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. Long point above 6Mtr upto 10Mtr from tapping point to outlet via switch boxEach639.56639.5670.0FalseNoneNoneFalseNoneFalse44769.20
278052888687Nonecode24Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2x1.5 sqmm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet.Two outlet in a row, above 3Mtr upto 6Mtr from tapping point to outlet via switchs.Each455.48455.48200.0FalseNoneNoneFalseNoneFalse91096.00
278052988687Nonecode25Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2x1.5 sqmm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet.Two outlet in a rowThree above 6Mtr upto 10Mtr from tapping point to outlet via switchs boxEach669.06669.0630.0FalseNoneNoneFalseNoneFalse20071.80
278053088687Nonecode26Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.4 sqmmMtr69.6269.62500.0FalseNoneNoneFalseNoneFalse34810.00
278053188687Nonecode27Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmmMtr102.66102.66800.0FalseNoneNoneFalseNoneFalse82128.00
278053288687Nonecode28Supplying 6A flush type socket and 6 amps flush type SP switch either surface or flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654Each142.78142.78400.0FalseNoneNoneFalseNoneFalse57112.00
278053388687Nonecode29Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board. 16Combined switch and socket with indicationEach330.4330.480.0FalseNoneNoneFalseNoneFalse26432.00
278053488687Nonecode30Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5 WayEach162.84162.84150.0FalseNoneNoneFalseNoneFalse24426.00
278053588687Nonecode31Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 3 ModuleEach179.36179.36280.0FalseNoneNoneFalseNoneFalse50220.80
278053688687Nonecode32Supplying and fixing of modular switch/socket/stepped electronic fan regulator or dimmer or telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293Each103.84103.84220.0FalseNoneNoneFalseNoneFalse22844.80
278053788687Nonecode33Supplying and fixing of modular switch/socket/stepped electronic fan regulator or dimmer or telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16Amps one way switchEach293.82293.82140.0FalseNoneNoneFalseNoneFalse41134.80
278053888687Nonecode34Supplying and fixing of modular switch/socket/stepped electronic fan regulator or dimmer or telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 TV/Television socketEach173.46173.4615.0FalseNoneNoneFalseNoneFalse2601.90
278053988687Nonecode35Supplying and fixing of modular switch/socket/stepped electronic fan regulator or dimmer or telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 RJ45/ I.O. outletEach248.98248.9830.0FalseNoneNoneFalseNoneFalse7469.40
278054088687Nonecode36Supplying and fixing of metal clad industrial plugs and sockets 2pole+earth 250VEach259.6259.6180.0FalseNoneNoneFalseNoneFalse46728.00
278054188687Nonecode37Supplying and fixing of metal clad industrial plugs and sockets 3pole+earth 440VEach330.4330.4230.0FalseNoneNoneFalseNoneFalse75992.00
278054288687Nonecode38Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with all accessories complete and Excluding batteries and wiring complete.Each140447.14140447.141.0FalseNoneNoneFalseNoneFalse140447.140
278054388687Nonecode39Supplying, installation, testing & commissioning of 12V DC,AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 75 / 80 AH capacityEach12682.6412682.6412.0FalseNoneNoneFalseNoneFalse152191.680
278054488687Nonecode40Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.Each828.36828.3620.0FalseNoneNoneFalseNoneFalse16567.20
278054588687Nonecode41Supplying and Drawing PVC flexible one Pair telephone Unarmoured tinned Copper CableMtr68.4468.44300.0FalseNoneNoneFalseNoneFalse20532.00
278054688687Nonecode42Supplying and fixing 2mm thick perforated cable GI tray with on existing MS angle support using necessary GI bolts/nuts and washer or welding as required. 150x50mmMtr448.4448.470.0FalseNoneNoneFalseNoneFalse31388.00
278054788687Nonecode43Supplying and fixing 2mm thick perforated cable GI tray with on existing MS angle support using necessary GI bolts/nuts and washer or welding as required.300x50mmMtr625.4625.490.0FalseNoneNoneFalseNoneFalse56286.00
278054888687Nonecode44Supplying and fixing 2mm thick perforated cable GI tray with on existing MS angle support using necessary GI bolts/nuts and washer or welding as required.450x50mmMtr965.24965.2420.0FalseNoneNoneFalseNoneFalse19304.80
278054988687Nonecode45Supplying and fixing 2mm thick perforated cable GI tray with on existing MS angle support using necessary GI bolts/nuts and washer or welding as required.600x50mmMtr1020.71020.740.0FalseNoneNoneFalseNoneFalse40828.00
278055088687Nonecode46Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.No6490.06490.05.0FalseNoneNoneFalseNoneFalse32450.00
278055188687Nonecode47Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GIMtr88.588.5200.0FalseNoneNoneFalseNoneFalse17700.00
278055288687Nonecode48Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI 25x6mm GIMtr135.7135.7100.0FalseNoneNoneFalseNoneFalse13570.00
278055388687Nonecode49Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI 50x6mm GIMtr230.1230.1100.0FalseNoneNoneFalseNoneFalse23010.00
278055488687Nonecode50Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required 50x6mm CUMtr2295.12295.130.0FalseNoneNoneFalseNoneFalse68853.00
278055588687Nonecode51Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required 25x6mm CUMtr1130.441130.4480.0FalseNoneNoneFalseNoneFalse90435.20
278055688687Nonecode52Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60H & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.(MIRROR LIGHT)Each1412.461412.4670.0FalseNoneNoneFalseNoneFalse98872.20
278055788687Nonecode53Supply of LED pole mounting type post top lantern with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/ clear glass material, delivering superior light output.Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60H application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB . LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have inhouse facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/umileds/Osram make LED Source. LED Post Top Lantern with 35 wattsNo9336.169336.1610.0FalseNoneNoneFalseNoneFalse93361.60
278055888687Nonecode54Design, supplying, erecting testing and commissioning of - passenger/ Bed-cum-passenger hospital lift with speed of 1mtr per second, variable voltage variable frequency drive, with or without machine room for the available well size, operating at 415 V 3 phase 50 cycles AC supply, powder coated / Stainless Steel car entrance doors enclosures with suitable colour vinyl flooring, LED car illumination, emergency light, intercom and fan as desired by the user, central opening / side opening door with or without attendant operation, 7 segment display buttons, call register indicator, fireman drive, SS handrails inside car, full length infrared curtain in car door, automatic rescue device with batteries, voice announcing in regional / international languages, Braille buttons with one year warranty and maintenance with necessary scaffolding and minor civil works like fixing of guide rail, counter weight etc.,With machine room-PC Finish---8 Passenger elevator is geared equipment Capacity--2 stopsNo1479484.01479484.01.0FalseNoneNoneFalseNoneFalse1479484.00
278055988687Nonecode55Supplying, installing, testing and commissioning of DieselGenerator set with following specifications. Power rating asper standard reference condition as per-BS 5514 / ISO 3046 /ISO 8528 & IS 1002 / ISO 3046 Generator set specifications. 250 kVA/200 kW Detailed Specification as per SRSet4216877.54216877.51.0FalseNoneNoneFalseNoneFalse4216877.50
278056088687Nonecode56Supply, Erection, testing and commissioning of AMFpanel suitable for .....KVA DG set. The panel is of cubicaltype base/floor mounting control panel with hinged doors,undrilled bottom gland plate, aluminium Bus Bar with theaccommodation for .....amps 4 pole contactor for alternatorwith thermal O/L relay,..... Amps 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor basedAMF module with supply failure timer, Restoration timer, 3impulse automatic engine start/stop logic, Mains/generatorvoltage, ....capacity bypass switch and frequency sensing, PCC 1301 controller with water temperature/Lube oilpressure/ engine speed, Voltage/ampere/Frequency/ KVA,Running-hour count, No of starts, Fault indication, over /under speed, Fails to start, Low oil pleasure, High enginetemperature, Under/over voltage, over current, Earth faultrelay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMf module by pass Mode, Batterycharger unit with inbuilt Auto/Manual and Flat/Boost facility. Above 62.5 KVA upto 125 KVASet559762.5559762.51.0FalseNoneNoneFalseNoneFalse559762.50
17086731800001NoneNoneBuildingsconstruction of pandavapura sub office for MANMUL49651790.7
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
278096688711Nonecode01Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Complete with all lead and lift as per the instruction of the Engineer in incharge.Cum88.7288.72629.06FalseNoneNoneFalseNoneFalse55810.20320
278121988711Nonecode01Constructing brick masonry chamber of internal dimension 600x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. complete with all lead and lift as per the direction of Engineer-In-ChargeEach5316.165316.168.0FalseNoneNoneFalseNoneFalse42529.280
278131388711Nonecode01Supply Erection testing and commissioning of of 11KV load break switch with 4 wire-(3 CT with nuetral) metering cubicle and connecting accessories suitable for outdoor type complete as per latest IS standards and ESCOM approved technical specification metering cubicle with LBSNo340580.92340580.921.0FalseNoneNoneFalseNoneFalse340580.920
278096788711Nonecode02Earth work excavation for Foundation by mechanical means for all works & depth 3 m to 6 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Complete with all lead and lift as per the instruction of the Engineer in incharge.Cum102.09102.09446.68FalseNoneNoneFalseNoneFalse45601.56120
278122088711Nonecode02Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.. complete with all lead and lift as per the direction of Engineer-In-ChargeEach6049.056049.052.0FalseNoneNoneFalseNoneFalse12098.10
278131488711Nonecode02Supply, erection, testing and commissioning of ...500.. KVA 5 Star rated Aluminium/Copper wound Distribution Transformer 11KV/433V with Off Load Tap Switch, Buchholtz relay winding temperature indicator, oil temperature indicator, marshalling box with wiring, oil level indicator with + 5% to -10% Steps of 2.5%, HT and LT Cable Entry Box Type, stacked core with oil as per IS:1180(Part-1):2014 with all standard accessories as per latest IS standard No:2026/1977 and IS:335, technical specification & ESCOM 500 KVA - Aluminium WoundNo1416000.01416000.01.0FalseNoneNoneFalseNoneFalse1416000.00
278096888711Nonecode03Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. Complete with all lead and lift as per the instruction of the Engineer in incharge.Cum247.94247.94123.72FalseNoneNoneFalseNoneFalse30675.13680
278122188711Nonecode03Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.In all kinds of soils. Depth upto 1.50m complete with all lead and lift as per the direction of Engineer-In-ChargeCum450.91450.9116.2FalseNoneNoneFalseNoneFalse7304.7420
278131588711Nonecode03HT Cable Group A Supplying & Laying of High Tension 11kVCable Dry Curing & Dry Cooling With true triple Extrusion , Simltaneously Through a Single Common head 3Core under Ground XLPE ( E ) Cable having stranded Compact Circular Aluminium Conductor , Screened insulated , insulation screened with extruded semiconducting compound in combination with copper tape core laid up extruded inner shelthed of GI flat strip armoured and over all PVC Sheathed with Specified IS 7098 / 11 /85 with latest amendments & confirming to the GTP of Group -AMtr1628.41628.4140.0FalseNoneNoneFalseNoneFalse227976.00
278096988711Nonecode04Cost of Haulage Excluding Loading and Unloading, Loading and Unloading of Stone Boulder/Stone aggregates/Sand/Kankar/Moorum.(Tipper 10 m3). Basement floor Complete with all lead and lift as per the instruction of the Engineer in incharge.Cum488.59488.59952.02FalseNoneNoneFalseNoneFalse465147.45180
278122288711Nonecode04Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 complete with all lead and lift as per the direction of Engineer-In-ChargeMtr478.87478.8765.0FalseNoneNoneFalseNoneFalse31126.550
278131688711Nonecode04Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 3.5 core 185 sqmm.Mtr1056.11056.1100.0FalseNoneNoneFalseNoneFalse105610.00
278097088711Nonecode05Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. Complete with all lead and lift as per the instruction of the Engineer in incharge.Cum100.88100.8888.5FalseNoneNoneFalseNoneFalse8927.880
278122388711Nonecode05Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 140mm dia., 6 kg/sqcm & class 3 complete with all lead and lift as per the direction of Engineer-In-ChargeMtr689.13689.1365.0FalseNoneNoneFalseNoneFalse44793.450
278131788711Nonecode05Supply and fixing regular MCCB distribution panel confirming IS 8828, on wall/wood board/flush mounting using clamps,bolts,nuts etc with provision for fixing suitable type capacity MCCB as an incomer for 3pahse double door necessary bus bar completely wired to use on 440 volts 3 phase 4 wire powder coated paiting etc complete with a provision for fixing of single/three phase suitable capacity MCCb/MCB's as outgoings confirming to IEC 60898 700 A MCCB.No51358.3251358.321.0FalseNoneNoneFalseNoneFalse51358.320
278097188711Nonecode06Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier underand around the column pits, walls, trenches, basement excavation,top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications Complete with all lead and lift as per the instruction of the Engineer in incharge.Sqm115.46115.46723.76FalseNoneNoneFalseNoneFalse83565.32960
278122488711Nonecode06Providing and placing on terrace (at all floor levels), polyethylene water storage tanks, IS:127001 marked, with cover and suitable locking arrangements, making necessary holes for inlet, outlet and over flow pipes but without fittings and the base support for tank. complete with all lead and lift as per the direction of Engineer-In-ChargeLtr9.729.724000.0FalseNoneNoneFalseNoneFalse38880.00
278131888711Nonecode06Supplying heavy gauge PVC conduit pipe ……dia…..mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall /stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 19/20mm dia 2mm thickMtr80.2480.24950.0FalseNoneNoneFalseNoneFalse76228.00
278097288711Nonecode07Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates. Ground Floor Complete with all lead and lift as per the instruction of the Engineer in incharge.Cum6961.816961.81118.26FalseNoneNoneFalseNoneFalse823303.65060
278122588711Nonecode07Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 20 mm Dia (Ground Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeMtr261.31261.3140.0FalseNoneNoneFalseNoneFalse10452.40
278131988711Nonecode07Supplying heavy gauge PVC conduit pipe ……dia…..mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall /stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25mm dia 2mm thickMtr94.494.41800.0FalseNoneNoneFalseNoneFalse169920.00
278097388711Nonecode08Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) Complete with all lead and lift as per the instruction of the Engineer in incharge.Cum6504.826504.8215.66FalseNoneNoneFalseNoneFalse101865.48120
278122688711Nonecode08Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 20 mm Dia (First Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeMtr261.31261.3135.0FalseNoneNoneFalseNoneFalse9145.850
278132088711Nonecode08Supplying PVC/GI flexible conduit pipe….mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely. 20mmMtr29.529.5500.0FalseNoneNoneFalseNoneFalse14750.00
278097488711Nonecode09Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates as per the directions and instructions of engineer in charge. Ground Floor Complete with all lead and lift as per the instruction of the Engineer in incharge.Cum7266.887266.88202.02FalseNoneNoneFalseNoneFalse1468055.09760
278122788711Nonecode09Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 20 mm Dia (Second Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeMtr261.31261.3130.0FalseNoneNoneFalseNoneFalse7839.30
278132188711Nonecode09Supplying PVC/GI flexible conduit pipe….mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely. 25mmMtr123.9123.9500.0FalseNoneNoneFalseNoneFalse61950.00
278097588711Nonecode10Providing, fixing and removing of formwork, Centering, shuttering and scaffolding for footing (of item No 25) complete with all lead and lift as per the direction of Engineer-In-Charge Complete with all lead and lift as per the instruction of the Engineer in incharge.Cum325.24325.24202.02FalseNoneNoneFalseNoneFalse65704.98480
278122888711Nonecode10Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 20 mm Dia (Third Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeMtr261.31261.3125.0FalseNoneNoneFalseNoneFalse6532.750
278132288711Nonecode10Supplying heavy gauge PVC conduit pipe …….dia .......mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. . 32mm dia 2.5mm thickMtr108.56108.56400.0FalseNoneNoneFalseNoneFalse43424.00
278097688711Nonecode11Providing and laying in position Reinforced cement concrete for all Sub structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - complete with all lead and lift as per the direction of Engineer-In-Charge. Ground floor Complete with all lead and lift as per the instruction of the Engineer in incharge.Cum7282.687282.6853.78FalseNoneNoneFalseNoneFalse391662.53040
278122988711Nonecode11Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 20 mm Dia (Fourth Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeMtr363.4363.420.0FalseNoneNoneFalseNoneFalse7268.00
278132388711Nonecode11Supplying push button operated direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet or iron clad enclosure and fixing the same to suitable capacity wires for 400/440 volts 3 phase motor/single phase motor upto 5 HPEach1758.21758.22.0FalseNoneNoneFalseNoneFalse3516.40
278097788711Nonecode12Providing, fixing and removing of formwork, Centering, shuttering and scaffolding for footing. Basement floor Complete with all lead and lift as per the instruction of the Engineer in incharge.Cum5097.875097.8712.59FalseNoneNoneFalseNoneFalse64182.18330
278123088711Nonecode12Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm Dia (Ground Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeMtr363.4363.440.0FalseNoneNoneFalseNoneFalse14536.00
278132488711Nonecode12Supplying fully automatic star-delta starter unit push button type with suitable wires, 3 contactors, one adjustable thermal timer mounted on a common base plate held in steel enclosure for use on 400/440 volts 3 phase and wired after fixing to the existing wooden board for motor.Each7552.07552.02.0FalseNoneNoneFalseNoneFalse15104.00
278097888711Nonecode13Providing, fixing and removing of formwork, Centering, shuttering and scaffolding for plinth beam, slab & staircase Substructure Works. Basement floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum3641.343641.3431.84FalseNoneNoneFalseNoneFalse115940.26560
278123188711Nonecode13Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm Dia (First Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeMtr363.4363.435.0FalseNoneNoneFalseNoneFalse12719.00
278132588711Nonecode13Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (Icu = Ics) 400 AEach30680.030680.03.0FalseNoneNoneFalseNoneFalse92040.00
278097988711Nonecode14Providing, fixing and removing of formwork, Centering, shuttering and scaffolding for RC wall Substructure Works. Basement floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum5097.875097.879.35FalseNoneNoneFalseNoneFalse47665.08450
278123288711Nonecode14Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm Dia (Second Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeMtr363.4363.430.0FalseNoneNoneFalseNoneFalse10902.00
278132688711Nonecode14Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 5-32 Amps SPEach617.14617.1470.0FalseNoneNoneFalseNoneFalse43199.80
278098088711Nonecode15Providing and laying in position Reinforced cement concrete for all Super structures ofbuilding , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - Ground floor Works complete with all lead and lift as per the direction of Engineer-In-ChargeCum7518.467518.46100.42FalseNoneNoneFalseNoneFalse755003.75320
278123388711Nonecode15Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm Dia (Third Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeMtr363.4363.425.0FalseNoneNoneFalseNoneFalse9085.00
278132788711Nonecode15Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 Amps SPEach856.68856.6820.0FalseNoneNoneFalseNoneFalse17133.60
278098188711Nonecode16Providing, fixing and removing of formwork, Centering, shuttering and scaffolding (of Item No 32) for column. Basement floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum5262.935262.9314.13FalseNoneNoneFalseNoneFalse74365.20090
278123488711Nonecode16Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm Dia (Fourth Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeMtr435.11435.1120.0FalseNoneNoneFalseNoneFalse8702.20
278132888711Nonecode16Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. 4 Way TP & NEach3602.543602.548.0FalseNoneNoneFalseNoneFalse28820.320
278098288711Nonecode17Providing, fixing and removing of formwork, Centering, shuttering and scaffolding (of Item No 32) for beam & lintels. Basement floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum4511.084511.0830.74FalseNoneNoneFalseNoneFalse138670.59920
278123588711Nonecode17Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 32 mm Dia (Ground Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeMtr435.11435.1140.0FalseNoneNoneFalseNoneFalse17404.40
278132988711Nonecode17Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. 6Way TP &NEach4407.34407.38.0FalseNoneNoneFalseNoneFalse35258.40
278098388711Nonecode18Providing, fixing and removing of formwork, Centering, shuttering and scaffolding (of Item No 32) for slab & staircase. Basement floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum3759.233759.2355.55FalseNoneNoneFalseNoneFalse208825.22650
278123688711Nonecode18Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 32 mm Dia (First Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeMtr435.11435.1135.0FalseNoneNoneFalseNoneFalse15228.850
278133088711Nonecode18Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board.Each2950.02950.020.0FalseNoneNoneFalseNoneFalse59000.00
278098488711Nonecode19Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeKg111.82111.8237840.77FalseNoneNoneFalseNoneFalse4231354.90140
278123788711Nonecode19Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 32 mm Dia (Second Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeMtr435.11435.1130.0FalseNoneNoneFalseNoneFalse13053.30
278133188711Nonecode19Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB ). The entire plug and socket shall be mounted in a thermoplastic / powder coated metal box & wired Completely. 20AmpsEach1030.141030.1425.0FalseNoneNoneFalseNoneFalse25753.50
278098588711Nonecode20Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge. Complete Ground Floor Complete with all lead and lift as per the instruction of the Engineer in incharge.Sqm856.86856.86121.6FalseNoneNoneFalseNoneFalse104194.1760
278123888711Nonecode20Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 32 mm Dia (Third Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeMtr435.11435.1125.0FalseNoneNoneFalseNoneFalse10877.750
278133288711Nonecode20Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB ). The entire plug and socket shall be mounted in a thermoplastic / powder coated metal box & wired Completely. 30AmpsEach1810.121810.1260.0FalseNoneNoneFalseNoneFalse108607.20
278098688711Nonecode21Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding for works Ground Floor Works complete with all lead and lift as per the direction of Engineer-In-ChargeKg176.23176.23460.95FalseNoneNoneFalseNoneFalse81233.21850
278123988711Nonecode21Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 32 mm Dia (Fourth Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeMtr853.21853.2120.0FalseNoneNoneFalseNoneFalse17064.20
278133388711Nonecode21Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2x1.5 sqmm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch boxEach324.5324.5500.0FalseNoneNoneFalseNoneFalse162250.00
278098788711Nonecode22Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) -Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm8799.58799.513.74FalseNoneNoneFalseNoneFalse120905.130
278124088711Nonecode22Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm Dia (Ground Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeMtr853.21853.2140.0FalseNoneNoneFalseNoneFalse34128.40
278133488711Nonecode22Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2x1.5 sqmm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to outlet via switch boxEach425.98425.98200.0FalseNoneNoneFalseNoneFalse85196.00
278098888711Nonecode23Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) Ground Floor Works complete with all lead and lift as per the direction of Engineer-In-ChargeSqm8799.58799.50.9FalseNoneNoneFalseNoneFalse7919.550
278124188711Nonecode23Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm Dia (First Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeMtr853.21853.2135.0FalseNoneNoneFalseNoneFalse29862.350
278133588711Nonecode23Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2x1.5 sqmm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. Long point above 6Mtr upto 10Mtr from tapping point to outlet via switch boxEach639.56639.5670.0FalseNoneNoneFalseNoneFalse44769.20
278098988711Nonecode24Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum109863.65109863.650.15FalseNoneNoneFalseNoneFalse16479.54750
278124288711Nonecode24Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm Dia (Second Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeMtr853.21853.2130.0FalseNoneNoneFalseNoneFalse25596.30
278133688711Nonecode24Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2x1.5 sqmm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet.Two outlet in a row, above 3Mtr upto 6Mtr from tapping point to outlet via switchs.Each455.48455.48200.0FalseNoneNoneFalseNoneFalse91096.00
278099088711Nonecode25Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. do- 30 mm thick both side commercial. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm3206.233206.235.36FalseNoneNoneFalseNoneFalse17185.39280
278124388711Nonecode25Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm Dia (Third Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeMtr853.21853.2125.0FalseNoneNoneFalseNoneFalse21330.250
278133788711Nonecode25Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2x1.5 sqmm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet.Two outlet in a rowThree above 6Mtr upto 10Mtr from tapping point to outlet via switchs boxEach669.06669.0630.0FalseNoneNoneFalseNoneFalse20071.80
278099188711Nonecode26Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. Ground floor complete with all lead and lift as per the direction of Engineer-In-Chargem577.32577.3223.94FalseNoneNoneFalseNoneFalse13821.04080
278124488711Nonecode26Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm Dia (Fourth Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeMtr396.22396.2220.0FalseNoneNoneFalseNoneFalse7924.40
278133888711Nonecode26Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.4 sqmmMtr69.6269.62500.0FalseNoneNoneFalseNoneFalse34810.00
278099288711Nonecode27Providing and fixing factory made 100% carpenter friendly ready to use single solid plain wood polymer composite (WPC) flush shutter of 30mm thick which is anti terminate and having high water observation property. The cost include cost of material, transportation, labour and fixing charges. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm4227.164227.163.15FalseNoneNoneFalseNoneFalse13315.5540
278124588711Nonecode27Providing and fixing in position brass bib cock of approved quality 15mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. (Ground Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeEach396.22396.226.0FalseNoneNoneFalseNoneFalse2377.320
278133988711Nonecode27Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmmMtr102.66102.66800.0FalseNoneNoneFalseNoneFalse82128.00
278099388711Nonecode28Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos132.48132.483.0FalseNoneNoneFalseNoneFalse397.440
278124688711Nonecode28Providing and fixing in position brass bib cock of approved quality 15mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. (First Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeEach396.22396.2210.0FalseNoneNoneFalseNoneFalse3962.20
278134088711Nonecode28Supplying 6A flush type socket and 6 amps flush type SP switch either surface or flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654Each142.78142.78400.0FalseNoneNoneFalseNoneFalse57112.00
278099488711Nonecode29Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos1069.551069.553.0FalseNoneNoneFalseNoneFalse3208.650
278124788711Nonecode29Providing and fixing in position brass bib cock of approved quality 15mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. (Second Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeEach396.22396.2210.0FalseNoneNoneFalseNoneFalse3962.20
278134188711Nonecode29Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board. 16Combined switch and socket with indicationEach330.4330.480.0FalseNoneNoneFalseNoneFalse26432.00
278099588711Nonecode30Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos1011.211011.213.0FalseNoneNoneFalseNoneFalse3033.630
278124888711Nonecode30Providing and fixing in position brass bib cock of approved quality 15mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. (Third Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeEach396.22396.2210.0FalseNoneNoneFalseNoneFalse3962.20
278134288711Nonecode30Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5 WayEach162.84162.84150.0FalseNoneNoneFalseNoneFalse24426.00
278099688711Nonecode31Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos212.7212.76.0FalseNoneNoneFalseNoneFalse1276.20
278124988711Nonecode31Providing and fixing in position brass bib cock of approved quality 20mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. (Ground Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeEach419.31419.316.0FalseNoneNoneFalseNoneFalse2515.860
278134388711Nonecode31Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 3 ModuleEach179.36179.36280.0FalseNoneNoneFalseNoneFalse50220.80
278099788711Nonecode32Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90mm. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos99.6699.669.0FalseNoneNoneFalseNoneFalse896.940
278125088711Nonecode32Providing and fixing in position brass bib cock of approved quality 20mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. (First Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeEach419.31419.3110.0FalseNoneNoneFalseNoneFalse4193.10
278134488711Nonecode32Supplying and fixing of modular switch/socket/stepped electronic fan regulator or dimmer or telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293Each103.84103.84220.0FalseNoneNoneFalseNoneFalse22844.80
278099888711Nonecode33Providing and fixing bright finished brass tower bolts(barrel type) with necessary screws etc. complete : 250x10mm, Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach409.59409.599.0FalseNoneNoneFalseNoneFalse3686.310
278125188711Nonecode33Providing and fixing in position brass bib cock of approved quality 20mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. (Second Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeEach419.31419.3110.0FalseNoneNoneFalseNoneFalse4193.10
278134588711Nonecode33Supplying and fixing of modular switch/socket/stepped electronic fan regulator or dimmer or telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16Amps one way switchEach293.82293.82140.0FalseNoneNoneFalseNoneFalse41134.80
278099988711Nonecode34Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm8444.68444.6211.77FalseNoneNoneFalseNoneFalse1788312.9420
278125288711Nonecode34Providing and fixing in position brass bib cock of approved quality 20mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. (Third Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeEach419.31419.3110.0FalseNoneNoneFalseNoneFalse4193.10
278134688711Nonecode34Supplying and fixing of modular switch/socket/stepped electronic fan regulator or dimmer or telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 TV/Television socketEach173.46173.4615.0FalseNoneNoneFalseNoneFalse2601.90
278100088711Nonecode35Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm1086.571086.5715.39FalseNoneNoneFalseNoneFalse16722.31230
278125388711Nonecode35Providing and fixing ball valve (brass) of approved quality, High or low-pressure, with plastic floats complete : 20 mm Dia (Ground Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeEach437.54437.545.0FalseNoneNoneFalseNoneFalse2187.70
278134788711Nonecode35Supplying and fixing of modular switch/socket/stepped electronic fan regulator or dimmer or telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 RJ45/ I.O. outletEach248.98248.9830.0FalseNoneNoneFalseNoneFalse7469.40
278100188711Nonecode36Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm1289.541289.54104.4FalseNoneNoneFalseNoneFalse134627.9760
278125488711Nonecode36Providing and fixing ball valve (brass) of approved quality, High or low-pressure, with plastic floats complete : 20 mm Dia (First Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeEach437.54437.545.0FalseNoneNoneFalseNoneFalse2187.70
278134888711Nonecode36Supplying and fixing of metal clad industrial plugs and sockets 2pole+earth 250VEach259.6259.6180.0FalseNoneNoneFalseNoneFalse46728.00
278100288711Nonecode37Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge Ground Floor Works complete with all lead and lift as per the direction of Engineer-In-ChargeSqm3050.653050.6511.52FalseNoneNoneFalseNoneFalse35143.4880
278125588711Nonecode37Providing and fixing ball valve (brass) of approved quality, High or low-pressure, with plastic floats complete : 20 mm Dia (Second Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeEach437.54437.545.0FalseNoneNoneFalseNoneFalse2187.70
278134988711Nonecode37Supplying and fixing of metal clad industrial plugs and sockets 3pole+earth 440VEach330.4330.4230.0FalseNoneNoneFalseNoneFalse75992.00
278100388711Nonecode38Providing 12 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners with chicken mesh all around the wall with smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm258.88258.88405.36FalseNoneNoneFalseNoneFalse104939.59680
278125688711Nonecode38Providing and fixing ball valve (brass) of approved quality, High or low-pressure, with plastic floats complete : 20 mm Dia (Third Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeEach437.54437.545.0FalseNoneNoneFalseNoneFalse2187.70
278135088711Nonecode38Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with all accessories complete and Excluding batteries and wiring complete.Each140447.14140447.141.0FalseNoneNoneFalseNoneFalse140447.140
278100488711Nonecode39Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-incharge for works Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm301.42301.42488.94FalseNoneNoneFalseNoneFalse147376.29480
278125788711Nonecode39Providing and fixing ball valve (brass) of approved quality, High or low-pressure, with plastic floats complete : 20 mm Dia (Fourth Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeEach466.71466.715.0FalseNoneNoneFalseNoneFalse2333.550
278135188711Nonecode39Supplying, installation, testing & commissioning of 12V DC,AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 75 / 80 AH capacityEach12682.6412682.6412.0FalseNoneNoneFalseNoneFalse152191.680
278100588711Nonecode40Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm100.88100.88894.3FalseNoneNoneFalseNoneFalse90216.9840
278125888711Nonecode40Providing and fixing ball valve (brass) of approved quality, High or low-pressure, with plastic floats complete : 25 mm Dia (Ground Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeEach466.71466.712.0FalseNoneNoneFalseNoneFalse933.420
278135288711Nonecode40Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.Each828.36828.3620.0FalseNoneNoneFalseNoneFalse16567.20
278100688711Nonecode41Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm373.13373.13335.98FalseNoneNoneFalseNoneFalse125364.21740
278125988711Nonecode41Providing and fixing ball valve (brass) of approved quality, High or low-pressure, with plastic floats complete : 25 mm Dia (First Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeEach466.71466.712.0FalseNoneNoneFalseNoneFalse933.420
278135388711Nonecode41Supplying and Drawing PVC flexible one Pair telephone Unarmoured tinned Copper CableMtr68.4468.44300.0FalseNoneNoneFalseNoneFalse20532.00
278100788711Nonecode42Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm2294.682294.6850.6FalseNoneNoneFalseNoneFalse116110.8080
278126088711Nonecode42Providing and fixing ball valve (brass) of approved quality, High or low-pressure, with plastic floats complete : 25 mm Dia (Second Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeEach466.71466.712.0FalseNoneNoneFalseNoneFalse933.420
278135488711Nonecode42Supplying and fixing 2mm thick perforated cable GI tray with on existing MS angle support using necessary GI bolts/nuts and washer or welding as required. 150x50mmMtr448.4448.470.0FalseNoneNoneFalseNoneFalse31388.00
278100888711Nonecode43Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm3488.23488.290.03FalseNoneNoneFalseNoneFalse314042.6460
278126188711Nonecode43Providing and fixing ball valve (brass) of approved quality, High or low-pressure, with plastic floats complete : 25 mm Dia (Third Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeEach466.71466.712.0FalseNoneNoneFalseNoneFalse933.420
278135588711Nonecode43Supplying and fixing 2mm thick perforated cable GI tray with on existing MS angle support using necessary GI bolts/nuts and washer or welding as required.300x50mmMtr625.4625.490.0FalseNoneNoneFalseNoneFalse56286.00
278100988711Nonecode44Providing and fixing 20mm thick gang saw water cut Lakared granite for cladding in CM 1:3 (1 cement : 3 coarse sand) proportion with a coat of rough plastering using CM 1:4 (1 cement : 4 fine sand), cut to required shape, pattern with paper joints, finished with cement mortar using white cement and colour pigments to match the colour of slab making through jointing with sealant, grooves in joints including cost of curing etc., complete including cost and conveyance of all materials, mortar, labour for all items of work, usage charges of machinery etc., complete as per specification. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm3614.273614.275.02FalseNoneNoneFalseNoneFalse18143.63540
278126288711Nonecode44Providing and fixing ball valve (brass) of approved quality, High or low-pressure, with plastic floats complete : 25 mm Dia (Fourth Floor) complete with all lead and lift as per the direction of Engineer-In-ChargeEach466.71466.712.0FalseNoneNoneFalseNoneFalse933.420
278135688711Nonecode44Supplying and fixing 2mm thick perforated cable GI tray with on existing MS angle support using necessary GI bolts/nuts and washer or welding as required.450x50mmMtr965.24965.2420.0FalseNoneNoneFalseNoneFalse19304.80
278101088711Nonecode45Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. Ground floor complete with all lead and lift as per the direction of Engineer-In-Chargem326.94326.9450.2FalseNoneNoneFalseNoneFalse16412.3880
278126388711Nonecode45Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps Ground Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach3073.753073.752.0FalseNoneNoneFalseNoneFalse6147.50
278135788711Nonecode45Supplying and fixing 2mm thick perforated cable GI tray with on existing MS angle support using necessary GI bolts/nuts and washer or welding as required.600x50mmMtr1020.71020.740.0FalseNoneNoneFalseNoneFalse40828.00
278101188711Nonecode46Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. - Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm735.32735.327.95FalseNoneNoneFalseNoneFalse5845.7940
278126488711Nonecode46Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps First Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach3073.753073.755.0FalseNoneNoneFalseNoneFalse15368.750
278135888711Nonecode46Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.No6490.06490.05.0FalseNoneNoneFalseNoneFalse32450.00
278101288711Nonecode47Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm1171.651171.6519.47FalseNoneNoneFalseNoneFalse22812.02550
278126588711Nonecode47Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps Second Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach3073.753073.755.0FalseNoneNoneFalseNoneFalse15368.750
278135988711Nonecode47Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GIMtr88.588.5200.0FalseNoneNoneFalseNoneFalse17700.00
278101388711Nonecode48Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm1959.221959.220.41FalseNoneNoneFalseNoneFalse803.28020
278126688711Nonecode48Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps Fourth Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach3073.753073.754.0FalseNoneNoneFalseNoneFalse12295.00
278136088711Nonecode48Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI 25x6mm GIMtr135.7135.7100.0FalseNoneNoneFalseNoneFalse13570.00
278101488711Nonecode49Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm4193.134193.130.63FalseNoneNoneFalseNoneFalse2641.67190
278126788711Nonecode49Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. Ground Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach461.85461.853.0FalseNoneNoneFalseNoneFalse1385.550
278136188711Nonecode49Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI 50x6mm GIMtr230.1230.1100.0FalseNoneNoneFalseNoneFalse23010.00
278101588711Nonecode50Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer in- Charge. Ground Floor complete with all lead and lift as per the direction of Engineer-In-ChargeKg134.91134.911548.0FalseNoneNoneFalseNoneFalse208840.680
278126888711Nonecode50Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. First Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach461.85461.853.0FalseNoneNoneFalseNoneFalse1385.550
278136288711Nonecode50Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required 50x6mm CUMtr2295.12295.130.0FalseNoneNoneFalseNoneFalse68853.00
278101688711Nonecode51Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm48.6248.62894.3FalseNoneNoneFalseNoneFalse43480.8660
278126988711Nonecode51Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. Second Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach461.85461.853.0FalseNoneNoneFalseNoneFalse1385.550
278136388711Nonecode51Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required 25x6mm CUMtr1130.441130.4480.0FalseNoneNoneFalseNoneFalse90435.20
278101788711Nonecode52Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm96.0296.02894.3FalseNoneNoneFalseNoneFalse85870.6860
278127088711Nonecode52Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. Third Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach461.85461.853.0FalseNoneNoneFalseNoneFalse1385.550
278136488711Nonecode52Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60H & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.(MIRROR LIGHT)Each1412.461412.4670.0FalseNoneNoneFalseNoneFalse98872.20
278101888711Nonecode53Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm252.8252.8335.98FalseNoneNoneFalseNoneFalse84935.7440
278127188711Nonecode53Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm Ground Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach1056.181056.182.0FalseNoneNoneFalseNoneFalse2112.360
278136588711Nonecode53Supply of LED pole mounting type post top lantern with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/ clear glass material, delivering superior light output.Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60H application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB . LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have inhouse facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/umileds/Osram make LED Source. LED Post Top Lantern with 35 wattsNo9336.169336.1610.0FalseNoneNoneFalseNoneFalse93361.60
278101988711Nonecode54Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-incharge. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm109.39109.3938.64FalseNoneNoneFalseNoneFalse4226.82960
278127288711Nonecode54Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm First Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach1056.181056.183.0FalseNoneNoneFalseNoneFalse3168.540
278136688711Nonecode54Design, supplying, erecting testing and commissioning of - passenger/ Bed-cum-passenger hospital lift with speed of 1mtr per second, variable voltage variable frequency drive, with or without machine room for the available well size, operating at 415 V 3 phase 50 cycles AC supply, powder coated / Stainless Steel car entrance doors enclosures with suitable colour vinyl flooring, LED car illumination, emergency light, intercom and fan as desired by the user, central opening / side opening door with or without attendant operation, 7 segment display buttons, call register indicator, fireman drive, SS handrails inside car, full length infrared curtain in car door, automatic rescue device with batteries, voice announcing in regional / international languages, Braille buttons with one year warranty and maintenance with necessary scaffolding and minor civil works like fixing of guide rail, counter weight etc.,With machine room-PC Finish---8 Passenger elevator is geared equipment Capacity--2 stopsNo1479484.01479484.01.0FalseNoneNoneFalseNoneFalse1479484.00
278102088711Nonecode55Providing and laying heavy duty cobble stones 75mm thick interlock pavers, using cement and course sand for manufacture of blocks of approved size, shape and colour with a minimum compressive strength of 281 kg per m2 over 50mm thick sand bed ( average thickness ) and compacting with plate vibrator having 3 tons compaction force thereby forcing part of sand underneath to come up in between joints, final compaction of paver surface joints into its final level, including cost of materials, labour and Usage charges of machinery complete as per specifications. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum1391.631391.6361.0FalseNoneNoneFalseNoneFalse84889.430
278127388711Nonecode55Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm Second Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach1056.181056.183.0FalseNoneNoneFalseNoneFalse3168.540
278136788711Nonecode55Supplying, installing, testing and commissioning of DieselGenerator set with following specifications. Power rating asper standard reference condition as per-BS 5514 / ISO 3046 /ISO 8528 & IS 1002 / ISO 3046 Generator set specifications. 250 kVA/200 kW Detailed Specification as per SRSet4216877.54216877.51.0FalseNoneNoneFalseNoneFalse4216877.50
278102188711Nonecode56Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm49.8349.838.82FalseNoneNoneFalseNoneFalse439.50060
278127488711Nonecode56Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm Fourth Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach1056.181056.182.0FalseNoneNoneFalseNoneFalse2112.360
278136888711Nonecode56Supply, Erection, testing and commissioning of AMFpanel suitable for .....KVA DG set. The panel is of cubicaltype base/floor mounting control panel with hinged doors,undrilled bottom gland plate, aluminium Bus Bar with theaccommodation for .....amps 4 pole contactor for alternatorwith thermal O/L relay,..... Amps 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor basedAMF module with supply failure timer, Restoration timer, 3impulse automatic engine start/stop logic, Mains/generatorvoltage, ....capacity bypass switch and frequency sensing, PCC 1301 controller with water temperature/Lube oilpressure/ engine speed, Voltage/ampere/Frequency/ KVA,Running-hour count, No of starts, Fault indication, over /under speed, Fails to start, Low oil pleasure, High enginetemperature, Under/over voltage, over current, Earth faultrelay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMf module by pass Mode, Batterycharger unit with inbuilt Auto/Manual and Flat/Boost facility. Above 62.5 KVA upto 125 KVASet559762.5559762.51.0FalseNoneNoneFalseNoneFalse559762.50
278102288711Nonecode57Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete. up to Ground Floor.Sqm4787.464787.469.6FalseNoneNoneFalseNoneFalse45959.6160
278127588711Nonecode57Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests Ground Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach5160.595160.591.0FalseNoneNoneFalseNoneFalse5160.590
278102388711Nonecode58Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi -rigid, inorganic, non-combustible fibre glass wool insulation 50 mm thick, conforming to IS: 8183 and BS: 3958 Part 5. The insulation layer shall have facing (factory bonded on surface 1 of the fibre glass insulation layer), of black non-woven fibre glass tissue of nominal thickness 0.5 mm and nominal mass not less than 60 g/m2,made of randomly oriented glass fibres distributed in a binder by a wet-lay process including fixing 1.5 mm thick solid aluminum sheet backing using, 6 mm thick cement board including SS rivets, nuts, bolts, washers etc complete. up to First FloorSqm1898.451898.459.6FalseNoneNoneFalseNoneFalse18225.120
278127688711Nonecode58Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests First Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach5160.595160.592.0FalseNoneNoneFalseNoneFalse10321.180
278102488711Nonecode59Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in- Charge. For payment, only the actual area of glass on face 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2. (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevent Item*).“(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 K etc. . The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. Up to first floorSqm2103.862103.869.6FalseNoneNoneFalseNoneFalse20197.0560
278127788711Nonecode59Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests Second Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach5160.595160.592.0FalseNoneNoneFalseNoneFalse10321.180
278102588711Nonecode60Providing and fixing of clay tiles for cladding tiles of size 230x75x10mm thick on 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) & jointed with Adhesive/cement slurry over rough plaster surface excluding cost of rough plastered surface and the surface is painted with red apex paint and black apex paint into the groves. The work includes cost of all materials, labour charges for all items of work, usage charges for equipment, etc., complete as per specification.Up to first floorSqm2253.352253.359.9FalseNoneNoneFalseNoneFalse22308.1650
278127888711Nonecode60Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests Fourth Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach6083.086083.082.0FalseNoneNoneFalseNoneFalse12166.160
278102688711Nonecode61Providing and laying in position Reinforced cement concrete for all Super structures ofbuilding , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - First Floor Works complete with all lead and lift as per the direction of Engineer-In-ChargeCum7518.467518.4697.86FalseNoneNoneFalseNoneFalse735756.49560
278127988711Nonecode61Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid Ground Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach6083.086083.081.0FalseNoneNoneFalseNoneFalse6083.080
278102788711Nonecode62Providing, fixing and removing of formwork, Centering, shuttering and scaffolding for column First floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum5262.935262.9314.13FalseNoneNoneFalseNoneFalse74365.20090
278128088711Nonecode62Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid First Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach6083.086083.082.0FalseNoneNoneFalseNoneFalse12166.160
278102888711Nonecode63Providing, fixing and removing of formwork, Centering, shuttering and scaffolding (of Item No 32) for beam & lintels First floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum4511.084511.0830.05FalseNoneNoneFalseNoneFalse135557.9540
278128188711Nonecode63Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid Second Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach6083.086083.082.0FalseNoneNoneFalseNoneFalse12166.160
278102988711Nonecode64Providing, fixing and removing of formwork, Centering, shuttering and scaffolding (of Item No 32) for slab & staircase First floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum3759.233759.2353.69FalseNoneNoneFalseNoneFalse201833.05870
278128288711Nonecode64Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid Third Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach6083.086083.082.0FalseNoneNoneFalseNoneFalse12166.160
278103088711Nonecode65Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) First floor complete with all lead and lift as per the direction of Engineer-In-ChargeKg111.82111.8210570.78FalseNoneNoneFalseNoneFalse1182024.61960
278128388711Nonecode65Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern as per the directions and instructions of engineer in charge. Ground Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach4297.654297.652.0FalseNoneNoneFalseNoneFalse8595.30
278103188711Nonecode66Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm8551.558551.55256.25FalseNoneNoneFalseNoneFalse2191334.68750
278128488711Nonecode66Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern as per the directions and instructions of engineer in charge. First Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach4297.654297.652.0FalseNoneNoneFalseNoneFalse8595.30
278103288711Nonecode67Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm1086.571086.5745.48FalseNoneNoneFalseNoneFalse49417.20360
278128588711Nonecode67Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern as per the directions and instructions of engineer in charge. Second Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach4297.654297.652.0FalseNoneNoneFalseNoneFalse8595.30
278103388711Nonecode68Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. First floor complete with all lead and lift as per the direction of Engineer-In-Charge.Sqm3050.653050.652.88FalseNoneNoneFalseNoneFalse8785.8720
278128688711Nonecode68Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern as per the directions and instructions of engineer in charge. Third Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach4297.654297.652.0FalseNoneNoneFalseNoneFalse8595.30
278103488711Nonecode69Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding for works First floor complete with all lead and lift as per the direction of Engineer-In-ChargeKg176.23176.23516.6FalseNoneNoneFalseNoneFalse91040.4180
278128788711Nonecode69Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors: * 100mm inlet and 100mm outlet * Sand Cast Iron S&S as per IS:1729 Ground Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach1172.861172.864.0FalseNoneNoneFalseNoneFalse4691.440
278103588711Nonecode70Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) -First floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm8799.58799.522.8FalseNoneNoneFalseNoneFalse200628.60
278128888711Nonecode70Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors: * 100mm inlet and 100mm outlet * Sand Cast Iron S&S as per IS:1729 First Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach1172.861172.868.0FalseNoneNoneFalseNoneFalse9382.880
278103688711Nonecode71Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) First floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm5919.05919.01.8FalseNoneNoneFalseNoneFalse10654.20
278128988711Nonecode71Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors: * 100mm inlet and 100mm outlet * Sand Cast Iron S&S as per IS:1729 Second Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach1172.861172.868.0FalseNoneNoneFalseNoneFalse9382.880
278103788711Nonecode72Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum109863.65109863.650.26FalseNoneNoneFalseNoneFalse28564.5490
278129088711Nonecode72Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors: * 100mm inlet and 100mm outlet * Sand Cast Iron S&S as per IS:1729 Third Floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach1172.861172.868.0FalseNoneNoneFalseNoneFalse9382.880
278103888711Nonecode73Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. do- 30 mm thick both side commercial. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm3206.233206.2312.6FalseNoneNoneFalseNoneFalse40398.4980
278129188711Nonecode73Providing and fixing on wall surface unplasticised Rigid rain water pipes confirming to IS:13592 Type A, including jointing with seal ring confirming to IS:5382, leaving 10mm gap for thermal expansion, (i) Single socketed pipes 100mm diameter. Ground floor to First floor complete with all lead and lift as per the direction of Engineer-In-ChargeMtr307.5307.5200.0FalseNoneNoneFalseNoneFalse61500.00
278103988711Nonecode74Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. Ground floor.m577.32577.3247.88FalseNoneNoneFalseNoneFalse27642.08160
278129288711Nonecode74Providing and fixing on wall surface unplasticised Rigid rain water pipes confirming to IS:13592 Type A, including jointing with seal ring confirming to IS:5382, leaving 10mm gap for thermal expansion, (i) Single socketed pipes 100mm diameter. First floor to second floor complete with all lead and lift as per the direction of Engineer-In-ChargeMtr307.5307.5100.0FalseNoneNoneFalseNoneFalse30750.00
278104088711Nonecode75Providing and fixing factory made 100% carpenter friendly ready to use single solid plain wood polymer composite (WPC) flush shutter of 30mm thick which is anti terminate and having high water observation property. The cost include cost of material, transportation, labour and fixing charges. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm4227.164227.166.3FalseNoneNoneFalseNoneFalse26631.1080
278129388711Nonecode75Providing and fixing on wall surface unplasticised Rigid rain water pipes confirming to IS:13592 Type A, including jointing with seal ring confirming to IS:5382, leaving 10mm gap for thermal expansion, (i) Single socketed pipes 100mm diameter. Second floor to Third complete with all lead and lift as per the direction of Engineer-In-ChargeMtr307.5307.5100.0FalseNoneNoneFalseNoneFalse30750.00
278104188711Nonecode76Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos132.48132.486.0FalseNoneNoneFalseNoneFalse794.880
278129488711Nonecode76Providing and fixing on wall surface unplasticised Rigid rain water pipes confirming to IS:13592 Type A, including jointing with seal ring confirming to IS:5382, leaving 10mm gap for thermal expansion, (i) Single socketed pipes 100mm diameter. Third floor to terrace complete with all lead and lift as per the direction of Engineer-In-ChargeMtr307.5307.5100.0FalseNoneNoneFalseNoneFalse30750.00
278104288711Nonecode77Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos1069.551069.556.0FalseNoneNoneFalseNoneFalse6417.30
278129588711Nonecode77Cutting holes upto 30x30cm in walls including making good the same: with common burnt clay F.P.S (non modular) bricks. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach323.3323.310.0FalseNoneNoneFalseNoneFalse3233.00
278104388711Nonecode78Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos1011.211011.216.0FalseNoneNoneFalseNoneFalse6067.260
278129688711Nonecode78Cutting holes upto 30x30cm in walls including making good the same: with common burnt clay F.P.S (non modular) bricks. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach323.3323.310.0FalseNoneNoneFalseNoneFalse3233.00
278104488711Nonecode79Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos212.7212.712.0FalseNoneNoneFalseNoneFalse2552.40
278129788711Nonecode79Cutting holes upto 30x30cm in walls including making good the same: with common burnt clay F.P.S (non modular) bricks. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach323.3323.310.0FalseNoneNoneFalseNoneFalse3233.00
278104588711Nonecode80Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90mm. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos99.6699.6618.0FalseNoneNoneFalseNoneFalse1793.880
278129888711Nonecode80Cutting holes upto 30x30cm in walls including making good the same: with common burnt clay F.P.S (non modular) bricks. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach323.3323.340.0FalseNoneNoneFalseNoneFalse12932.00
278104688711Nonecode81Providing and fixing bright finished brass tower bolts(barrel type) with necessary screws etc. complete : 250x10mm, First floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach409.59409.5918.0FalseNoneNoneFalseNoneFalse7372.620
278129988711Nonecode81Cutting holes upto 15x15cm in RCC floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc, with cement concrete 1:2:4 (1 cement: 2 Coarse sand: 4 graded stone aggregate 20mm nominal size), including finishing complete so as to make it leak proof. Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeMtr295.34295.345.0FalseNoneNoneFalseNoneFalse1476.70
278104788711Nonecode82Providing 12 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners with chicken mesh all around the wall with smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm258.88258.88345.43FalseNoneNoneFalseNoneFalse89424.91840
278130088711Nonecode82Cutting holes upto 15x15cm in RCC floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc, with cement concrete 1:2:4 (1 cement: 2 Coarse sand: 4 graded stone aggregate 20mm nominal size), including finishing complete so as to make it leak proof. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeMtr295.34295.345.0FalseNoneNoneFalseNoneFalse1476.70
278104888711Nonecode83Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-incharge for works First floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm301.42301.42554.77FalseNoneNoneFalseNoneFalse167218.77340
278130188711Nonecode83Cutting holes upto 15x15cm in RCC floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc, with cement concrete 1:2:4 (1 cement: 2 Coarse sand: 4 graded stone aggregate 20mm nominal size), including finishing complete so as to make it leak proof. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeMtr295.34295.345.0FalseNoneNoneFalseNoneFalse1476.70
278104988711Nonecode84Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm100.88100.88900.21FalseNoneNoneFalseNoneFalse90813.18480
278130288711Nonecode84Cutting holes upto 15x15cm in RCC floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc, with cement concrete 1:2:4 (1 cement: 2 Coarse sand: 4 graded stone aggregate 20mm nominal size), including finishing complete so as to make it leak proof. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeMtr295.34295.342.0FalseNoneNoneFalseNoneFalse590.680
278105088711Nonecode85Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm373.13373.13293.0FalseNoneNoneFalseNoneFalse109327.090
278130388711Nonecode85Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 15 mm nominal bore Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos399.87399.872.0FalseNoneNoneFalseNoneFalse799.740
278105188711Nonecode86Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm2294.682294.6850.6FalseNoneNoneFalseNoneFalse116110.8080
278130488711Nonecode86Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 15 mm nominal bore First floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach399.87399.872.0FalseNoneNoneFalseNoneFalse799.740
278105288711Nonecode87Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm3488.23488.2267.45FalseNoneNoneFalseNoneFalse932919.090
278130588711Nonecode87Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 15 mm nominal bore Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos182.31182.312.0FalseNoneNoneFalseNoneFalse364.620
278105388711Nonecode88Providing and fixing 20mm thick gang saw water cut Lakared granite for cladding in CM 1:3 (1 cement : 3 coarse sand) proportion with a coat of rough plastering using CM 1:4 (1 cement : 4 fine sand), cut to required shape, pattern with paper joints, finished with cement mortar using white cement and colour pigments to match the colour of slab making through jointing with sealant, grooves in joints including cost of curing etc., complete including cost and conveyance of all materials, mortar, labour for all items of work, usage charges of machinery etc., complete as per specification. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm4251.474251.4711.07FalseNoneNoneFalseNoneFalse47063.77290
278130688711Nonecode88Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 15 mm nominal bore Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach199.33199.332.0FalseNoneNoneFalseNoneFalse398.660
278105488711Nonecode89Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. First floor complete with all lead and lift as per the direction of Engineer-In-Chargem326.94326.94187.6FalseNoneNoneFalseNoneFalse61333.9440
278130788711Nonecode89Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm Ground floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach5644.325644.322.0FalseNoneNoneFalseNoneFalse11288.640
278105588711Nonecode90Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. - First floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm735.32735.3222.35FalseNoneNoneFalseNoneFalse16434.4020
278130888711Nonecode90Providing and fixing of universal clamp of size 2.5 made out of mild steel including fixing with the drop in anchor and taper nut sleeve anchor complete including bolting, cost of labour and material GF to Terrace complete with all lead and lift as per the direction of Engineer-In-ChargeEach53.0453.04300.0FalseNoneNoneFalseNoneFalse15912.00
278105688711Nonecode91Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm1171.651171.6598.07FalseNoneNoneFalseNoneFalse114903.71550
278130988711Nonecode91Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete )Mtr678.19678.19200.0FalseNoneNoneFalseNoneFalse135638.00
278105788711Nonecode92Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm1959.221959.221.22FalseNoneNoneFalseNoneFalse2390.24840
278131088711Nonecode92Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty.Mtr2349.372349.37200.0FalseNoneNoneFalseNoneFalse469874.00
278105888711Nonecode93Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm4193.134193.131.26FalseNoneNoneFalseNoneFalse5283.34380
278131188711Nonecode93Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendmentsEach182.31182.311.0FalseNoneNoneFalseNoneFalse182.310
278105988711Nonecode94Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer in- Charge. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeKg134.91134.91504.0FalseNoneNoneFalseNoneFalse67994.640
278131288711Nonecode94Providing and laying at site of work MS casing caps as per IS 1239 (partII) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in chargeEach199.33199.331.0FalseNoneNoneFalseNoneFalse199.330
278106088711Nonecode95Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm48.6248.62900.21FalseNoneNoneFalseNoneFalse43768.21020
278106188711Nonecode96Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm96.0296.02900.21FalseNoneNoneFalseNoneFalse86438.16420
278106288711Nonecode97Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm252.8252.8293.0FalseNoneNoneFalseNoneFalse74070.40
278106388711Nonecode98Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-incharge First floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm109.39109.3927.48FalseNoneNoneFalseNoneFalse3006.03720
278106488711Nonecode99Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge. First floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm49.8349.8318.9FalseNoneNoneFalseNoneFalse941.7870
278106588711Nonecode100Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete. up to First Floor.Sqm4787.464787.469.6FalseNoneNoneFalseNoneFalse45959.6160
278106688711Nonecode101Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi -rigid, inorganic, non-combustible fibre glass wool insulation 50 mm thick, conforming to IS: 8183 and BS: 3958 Part 5. The insulation layer shall have facing (factory bonded on surface 1 of the fibre glass insulation layer), of black non-woven fibre glass tissue of nominal thickness 0.5 mm and nominal mass not less than 60 g/m2,made of randomly oriented glass fibres distributed in a binder by a wet-lay process including fixing 1.5 mm thick solid aluminum sheet backing using, 6 mm thick cement board including SS rivets, nuts, bolts, washers etc complete. up to First floor.Sqm1898.451898.459.6FalseNoneNoneFalseNoneFalse18225.120
278106788711Nonecode102Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in- Charge. For payment, only the actual area of glass on face 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2. (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevent Item*).“(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 K etc. . The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. Up to first floorSqm2103.862103.869.6FalseNoneNoneFalseNoneFalse20197.0560
278106888711Nonecode103Providing and fixing of clay tiles for cladding tiles of size 230x75x10mm thick on 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) & jointed with Adhesive/cement slurry over rough plaster surface excluding cost of rough plastered surface and the surface is painted with red apex paint and black apex paint into the groves. The work includes cost of all materials, labour charges for all items of work, usage charges for equipment, etc., complete as per specification.Up to first floorSqm2253.352253.359.9FalseNoneNoneFalseNoneFalse22308.1650
278106988711Nonecode104Providing and laying in position Reinforced cement concrete for all Super structures ofbuilding , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - Second Floor Works complete with all lead and lift as per the direction of Engineer-In-ChargeCum7518.467518.46136.43FalseNoneNoneFalseNoneFalse1025743.49780
278107088711Nonecode105Providing, fixing and removing of formwork, Centering, shuttering and scaffolding for column Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum5262.935262.9312.24FalseNoneNoneFalseNoneFalse64418.26320
278107188711Nonecode106Providing, fixing and removing of formwork, Centering, shuttering and scaffolding (of Item No 32) for beam & lintels. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum4511.084511.0881.17FalseNoneNoneFalseNoneFalse366164.36360
278107288711Nonecode107Providing, fixing and removing of formwork, Centering, shuttering and scaffolding (of Item No 32) for slab & staircase. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum3759.233759.2343.02FalseNoneNoneFalseNoneFalse161722.07460
278107388711Nonecode108Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeKg111.82111.8215643.35FalseNoneNoneFalseNoneFalse1749239.3970
278107488711Nonecode109Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm1453.621453.62232.22FalseNoneNoneFalseNoneFalse337559.63640
278107588711Nonecode110Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm1142.481142.4845.48FalseNoneNoneFalseNoneFalse51959.99040
278107688711Nonecode111Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. -Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum2451.462451.464.5FalseNoneNoneFalseNoneFalse11031.570
278107788711Nonecode112Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Second floor complete with all lead and lift as per the direction of Engineer-In-Charge.Sqm3050.653050.652.88FalseNoneNoneFalseNoneFalse8785.8720
278107888711Nonecode113Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding for works. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeKg176.23176.23554.4FalseNoneNoneFalseNoneFalse97701.9120
278107988711Nonecode114Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) -Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm8799.58799.524.6FalseNoneNoneFalseNoneFalse216467.70
278108088711Nonecode115Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm5919.05919.01.8FalseNoneNoneFalseNoneFalse10654.20
278108188711Nonecode116Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum109863.65109863.650.26FalseNoneNoneFalseNoneFalse28564.5490
278108288711Nonecode117Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. do- 30 mm thick both side commercial. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm3206.233206.2312.6FalseNoneNoneFalseNoneFalse40398.4980
278108388711Nonecode118Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. Second floor.m577.32577.3247.88FalseNoneNoneFalseNoneFalse27642.08160
278108488711Nonecode119Providing and fixing factory made 100% carpenter friendly ready to use single solid plain wood polymer composite (WPC) flush shutter of 30mm thick which is anti terminate and having high water observation property. The cost include cost of material, transportation, labour and fixing charges. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm4227.164227.166.3FalseNoneNoneFalseNoneFalse26631.1080
278108588711Nonecode120Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos132.48132.486.0FalseNoneNoneFalseNoneFalse794.880
278108688711Nonecode121Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos1069.551069.556.0FalseNoneNoneFalseNoneFalse6417.30
278108788711Nonecode122Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos1011.211011.216.0FalseNoneNoneFalseNoneFalse6067.260
278108888711Nonecode123Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos212.7212.712.0FalseNoneNoneFalseNoneFalse2552.40
278108988711Nonecode124Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90mm. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos99.6699.6618.0FalseNoneNoneFalseNoneFalse1793.880
278109088711Nonecode125Providing and fixing bright finished brass tower bolts(barrel type) with necessary screws etc. complete : 250x10mm, Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach409.59409.5918.0FalseNoneNoneFalseNoneFalse7372.620
278109188711Nonecode126Providing 12 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners with chicken mesh all around the wall with smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm258.88258.88360.19FalseNoneNoneFalseNoneFalse93245.98720
278109288711Nonecode127Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-incharge for works. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm301.42301.42501.82FalseNoneNoneFalseNoneFalse151258.58440
278109388711Nonecode128Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm100.88100.88710.56FalseNoneNoneFalseNoneFalse71681.29280
278109488711Nonecode129Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm373.13373.13255.38FalseNoneNoneFalseNoneFalse95289.93940
278109588711Nonecode130Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm2294.682294.6865.36FalseNoneNoneFalseNoneFalse149980.28480
278109688711Nonecode131Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm3488.23488.2310.8FalseNoneNoneFalseNoneFalse1084132.560
278109788711Nonecode132Providing and fixing 20mm thick gang saw water cut Lakared granite for cladding in CM 1:3 (1 cement : 3 coarse sand) proportion with a coat of rough plastering using CM 1:4 (1 cement : 4 fine sand), cut to required shape, pattern with paper joints, finished with cement mortar using white cement and colour pigments to match the colour of slab making through jointing with sealant, grooves in joints including cost of curing etc., complete including cost and conveyance of all materials, mortar, labour for all items of work, usage charges of machinery etc., complete as per specification. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm4251.474251.4710.07FalseNoneNoneFalseNoneFalse42812.30290
278109888711Nonecode133Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. Second floor complete with all lead and lift as per the direction of Engineer-In-Chargem326.94326.94100.7FalseNoneNoneFalseNoneFalse32922.8580
278109988711Nonecode134Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. - Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm735.32735.3222.35FalseNoneNoneFalseNoneFalse16434.4020
278110088711Nonecode135Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm1171.651171.6598.07FalseNoneNoneFalseNoneFalse114903.71550
278110188711Nonecode136Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm1959.221959.221.22FalseNoneNoneFalseNoneFalse2390.24840
278110288711Nonecode137Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm3013.133013.131.26FalseNoneNoneFalseNoneFalse3796.54380
278110388711Nonecode138Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer in- Charge. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeKg134.97134.97504.0FalseNoneNoneFalseNoneFalse68024.880
278110488711Nonecode139Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm48.6248.62710.56FalseNoneNoneFalseNoneFalse34547.42720
278110588711Nonecode140Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm96.0296.02710.56FalseNoneNoneFalseNoneFalse68227.97120
278110688711Nonecode141Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm252.8252.8255.38FalseNoneNoneFalseNoneFalse64560.0640
278110788711Nonecode142Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-incharge. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm109.39109.3929.28FalseNoneNoneFalseNoneFalse3202.93920
278110888711Nonecode143Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge. Second floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm49.8349.8318.9FalseNoneNoneFalseNoneFalse941.7870
278110988711Nonecode144Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete. up to Second Floor.Sqm4787.464787.469.6FalseNoneNoneFalseNoneFalse45959.6160
278111088711Nonecode145Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi -rigid, inorganic, non-combustible fibre glass wool insulation 50 mm thick, conforming to IS: 8183 and BS: 3958 Part 5. The insulation layer shall have facing (factory bonded on surface 1 of the fibre glass insulation layer), of black non-woven fibre glass tissue of nominal thickness 0.5 mm and nominal mass not less than 60 g/m2,made of randomly oriented glass fibres distributed in a binder by a wet-lay process including fixing 1.5 mm thick solid aluminum sheet backing using, 6 mm thick cement board including SS rivets, nuts, bolts, washers etc complete. up to Second floor.Sqm1898.451898.459.6FalseNoneNoneFalseNoneFalse18225.120
278111188711Nonecode146Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in- Charge. For payment, only the actual area of glass on face 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2. (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevent Item*).“(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 K etc. . The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. up to Second floor.Sqm2103.862103.869.6FalseNoneNoneFalseNoneFalse20197.0560
278111288711Nonecode147Providing and fixing of clay tiles for cladding tiles of size 230x75x10mm thick on 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) & jointed with Adhesive/cement slurry over rough plaster surface excluding cost of rough plastered surface and the surface is painted with red apex paint and black apex paint into the groves. The work includes cost of all materials, labour charges for all items of work, usage charges for equipment, etc., complete as per specification. up to Second floor.Sqm2253.352253.359.9FalseNoneNoneFalseNoneFalse22308.1650
278111388711Nonecode148Providing and laying in position Reinforced cement concrete for all Super structures ofbuilding , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - Third Floor Works complete with all lead and lift as per the direction of Engineer-In-ChargeCum7518.467518.46136.43FalseNoneNoneFalseNoneFalse1025743.49780
278111488711Nonecode149Providing, fixing and removing of formwork, Centering, shuttering and scaffolding for column. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum5262.935262.9312.24FalseNoneNoneFalseNoneFalse64418.26320
278111588711Nonecode150Providing, fixing and removing of formwork, Centering, shuttering and scaffolding (of Item No 32) for beam & lintels. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum4511.084511.0881.17FalseNoneNoneFalseNoneFalse366164.36360
278111688711Nonecode151Providing, fixing and removing of formwork, Centering, shuttering and scaffolding (of Item No 32) for slab & staircase. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum3759.233759.2343.02FalseNoneNoneFalseNoneFalse161722.07460
278111788711Nonecode152Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeKg111.82111.8215643.35FalseNoneNoneFalseNoneFalse1749239.3970
278111888711Nonecode153Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm1453.621453.62229.22FalseNoneNoneFalseNoneFalse333198.77640
278111988711Nonecode154Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Third floor complete with all lead and lift as per the direction of Engineer-In-Charge.Sqm3050.653050.652.88FalseNoneNoneFalseNoneFalse8785.8720
278112088711Nonecode155Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding for works. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeKg176.23176.23604.8FalseNoneNoneFalseNoneFalse106583.9040
278112188711Nonecode156Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) -Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm8799.58799.528.8FalseNoneNoneFalseNoneFalse253425.60
278112288711Nonecode157Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum109863.65109863.650.07FalseNoneNoneFalseNoneFalse7690.45550
278112388711Nonecode158Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. do- 30 mm thick both side commercial. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm3206.233206.232.52FalseNoneNoneFalseNoneFalse8079.69960
278112488711Nonecode159Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos132.48132.481.0FalseNoneNoneFalseNoneFalse132.480
278112588711Nonecode160Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos1069.551069.551.0FalseNoneNoneFalseNoneFalse1069.550
278112688711Nonecode161Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos1011.211011.211.0FalseNoneNoneFalseNoneFalse1011.210
278112788711Nonecode162Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos212.7212.72.0FalseNoneNoneFalseNoneFalse425.40
278112888711Nonecode163Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90mm. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos99.6699.663.0FalseNoneNoneFalseNoneFalse298.980
278112988711Nonecode164Providing and fixing bright finished brass tower bolts(barrel type) with necessary screws etc. complete : 250x10mm, Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach409.59409.593.0FalseNoneNoneFalseNoneFalse1228.770
278113088711Nonecode165Providing 12 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners with chicken mesh all around the wall with smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm258.88258.88360.19FalseNoneNoneFalseNoneFalse93245.98720
278113188711Nonecode166Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-incharge for works. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm301.42301.42308.56FalseNoneNoneFalseNoneFalse93006.15520
278113288711Nonecode167Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm100.88100.88668.75FalseNoneNoneFalseNoneFalse67463.50
278113388711Nonecode168Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm373.13373.13252.78FalseNoneNoneFalseNoneFalse94319.80140
278113488711Nonecode169Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm2294.682294.6864.25FalseNoneNoneFalseNoneFalse147433.190
278113588711Nonecode170Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm3488.23488.2310.8FalseNoneNoneFalseNoneFalse1084132.560
278113688711Nonecode171Providing and fixing 20mm thick gang saw water cut Lakared granite for cladding in CM 1:3 (1 cement : 3 coarse sand) proportion with a coat of rough plastering using CM 1:4 (1 cement : 4 fine sand), cut to required shape, pattern with paper joints, finished with cement mortar using white cement and colour pigments to match the colour of slab making through jointing with sealant, grooves in joints including cost of curing etc., complete including cost and conveyance of all materials, mortar, labour for all items of work, usage charges of machinery etc., complete as per specification. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm4251.474251.4710.37FalseNoneNoneFalseNoneFalse44087.74390
278113788711Nonecode172Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.Third floor complete with all lead and lift as per the direction of Engineer-In-Chargem326.94326.94104.78FalseNoneNoneFalseNoneFalse34256.77320
278113888711Nonecode173Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer in- Charge. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeKg134.91134.91552.0FalseNoneNoneFalseNoneFalse74470.320
278113988711Nonecode174Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm48.6248.62668.75FalseNoneNoneFalseNoneFalse32514.6250
278114088711Nonecode175Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm96.0296.02668.75FalseNoneNoneFalseNoneFalse64213.3750
278114188711Nonecode176Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm252.8252.8252.78FalseNoneNoneFalseNoneFalse63902.7840
278114288711Nonecode177Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-incharge. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm109.39109.3932.7FalseNoneNoneFalseNoneFalse3577.0530
278114388711Nonecode178Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge. Third floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm49.8349.832.52FalseNoneNoneFalseNoneFalse125.57160
278114488711Nonecode179Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete up to First floorSqm4787.464787.469.6FalseNoneNoneFalseNoneFalse45959.6160
278114588711Nonecode180Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi -rigid, inorganic, non-combustible fibre glass wool insulation 50 mm thick, conforming to IS: 8183 and BS: 3958 Part 5. The insulation layer shall have facing (factory bonded on surface 1 of the fibre glass insulation layer), of black non-woven fibre glass tissue of nominal thickness 0.5 mm and nominal mass not less than 60 g/m2,made of randomly oriented glass fibres distributed in a binder by a wet-lay process including fixing 1.5 mm thick solid aluminum sheet backing using, 6 mm thick cement board including SS rivets, nuts, bolts, washers etc complete. up to First FloorSqm1898.451898.459.6FalseNoneNoneFalseNoneFalse18225.120
278114688711Nonecode181Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in- Charge. For payment, only the actual area of glass on face 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2. (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevent Item*).“(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 K etc. . The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. Up to first floorSqm2103.862103.869.6FalseNoneNoneFalseNoneFalse20197.0560
278114788711Nonecode182Providing and fixing of clay tiles for cladding tiles of size 230x75x10mm thick on 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) & jointed with Adhesive/cement slurry over rough plaster surface excluding cost of rough plastered surface and the surface is painted with red apex paint and black apex paint into the groves. The work includes cost of all materials, labour charges for all items of work, usage charges for equipment, etc., complete as per specification.Up to first floorSqm2253.352253.359.9FalseNoneNoneFalseNoneFalse22308.1650
278114888711Nonecode183Providing and laying in position Reinforced cement concrete for all Super structures ofbuilding , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - Fourth Floor Works complete with all lead and lift as per the direction of Engineer-In-ChargeCum7518.467518.4636.38FalseNoneNoneFalseNoneFalse273521.57480
278114988711Nonecode184Providing, fixing and removing of formwork, Centering, shuttering and scaffolding for column. Fourth Floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum5262.935262.9311.16FalseNoneNoneFalseNoneFalse58734.29880
278115088711Nonecode185Providing, fixing and removing of formwork, Centering, shuttering and scaffolding (of Item No 32) for beam & lintels. Fourth Floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum4511.084511.0812.28FalseNoneNoneFalseNoneFalse55396.06240
278115188711Nonecode186Providing, fixing and removing of formwork, Centering, shuttering and scaffolding (of Item No 32) for slab & staircase. Fourth Floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum3759.233759.2312.95FalseNoneNoneFalseNoneFalse48682.02850
278115288711Nonecode187Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately). Fourth Floor complete with all lead and lift as per the direction of Engineer-In-ChargeKg111.82111.824008.19FalseNoneNoneFalseNoneFalse448195.80580
278115388711Nonecode188Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications for works. Fourth Floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm1453.621453.62173.03FalseNoneNoneFalseNoneFalse251519.86860
278115488711Nonecode189Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm1142.481142.4859.28FalseNoneNoneFalseNoneFalse67726.21440
278115588711Nonecode190Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. -Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum2451.462451.464.5FalseNoneNoneFalseNoneFalse11031.570
278115688711Nonecode191Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding for works. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeKg176.23176.23223.65FalseNoneNoneFalseNoneFalse39413.83950
278115788711Nonecode192Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) -Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm8799.58799.58.4FalseNoneNoneFalseNoneFalse73915.80
278115888711Nonecode193Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm5919.05919.02.25FalseNoneNoneFalseNoneFalse13317.750
278115988711Nonecode194Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum109863.65109863.650.26FalseNoneNoneFalseNoneFalse28564.5490
278116088711Nonecode195Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. do- 30 mm thick both side commercial. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm3206.233206.2312.6FalseNoneNoneFalseNoneFalse40398.4980
278116188711Nonecode196Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. Fourth floor.m577.32577.3247.88FalseNoneNoneFalseNoneFalse27642.08160
278116288711Nonecode197Providing and fixing factory made 100% carpenter friendly ready to use single solid plain wood polymer composite (WPC) flush shutter of 30mm thick which is anti terminate and having high water observation property. The cost include cost of material, transportation, labour and fixing charges. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm4227.164227.166.3FalseNoneNoneFalseNoneFalse26631.1080
278116388711Nonecode198Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos132.48132.486.0FalseNoneNoneFalseNoneFalse794.880
278116488711Nonecode199Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos1069.551069.556.0FalseNoneNoneFalseNoneFalse6417.30
278116588711Nonecode200Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos1011.211011.216.0FalseNoneNoneFalseNoneFalse6067.260
278116688711Nonecode201Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos212.7212.712.0FalseNoneNoneFalseNoneFalse2552.40
278116788711Nonecode202Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90mm. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos2.92.918.0FalseNoneNoneFalseNoneFalse52.20
278116888711Nonecode203Providing and fixing bright finished brass tower bolts(barrel type) with necessary screws etc. complete : 250x10mm, Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach409.59409.5918.0FalseNoneNoneFalseNoneFalse7372.620
278116988711Nonecode204Providing 12 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners with chicken mesh all around the wall with smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm258.88258.8867.17FalseNoneNoneFalseNoneFalse17388.96960
278117088711Nonecode205Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-incharge for works. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm301.42301.42419.37FalseNoneNoneFalseNoneFalse126406.50540
278117188711Nonecode206Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm100.88100.88329.91FalseNoneNoneFalseNoneFalse33281.32080
278117288711Nonecode207Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm373.13373.13145.85FalseNoneNoneFalseNoneFalse54421.01050
278117388711Nonecode208Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm2294.682294.6850.6FalseNoneNoneFalseNoneFalse116110.8080
278117488711Nonecode209Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm3488.23488.254.63FalseNoneNoneFalseNoneFalse190560.3660
278117588711Nonecode210Providing and fixing 20mm thick gang saw water cut Lakared granite for cladding in CM 1:3 (1 cement : 3 coarse sand) proportion with a coat of rough plastering using CM 1:4 (1 cement : 4 fine sand), cut to required shape, pattern with paper joints, finished with cement mortar using white cement and colour pigments to match the colour of slab making through jointing with sealant, grooves in joints including cost of curing etc., complete including cost and conveyance of all materials, mortar, labour for all items of work, usage charges of machinery etc., complete as per specification. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm4251.474251.473.83FalseNoneNoneFalseNoneFalse16283.13010
278117688711Nonecode211Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.Fourth floor complete with all lead and lift as per the direction of Engineer-In-Chargem326.94326.9438.3FalseNoneNoneFalseNoneFalse12521.8020
278117788711Nonecode212Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. - Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm735.32735.3215.6FalseNoneNoneFalseNoneFalse11470.9920
278117888711Nonecode213Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm1171.651171.65111.32FalseNoneNoneFalseNoneFalse130428.0780
278117988711Nonecode214Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm1959.221959.221.22FalseNoneNoneFalseNoneFalse2390.24840
278118088711Nonecode215Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm4193.134193.131.26FalseNoneNoneFalseNoneFalse5283.34380
278118188711Nonecode216Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer in- Charge. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeKg134.91134.91288.0FalseNoneNoneFalseNoneFalse38854.080
278118288711Nonecode217Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. . Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm48.6248.62329.91FalseNoneNoneFalseNoneFalse16040.22420
278118388711Nonecode218Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm96.0296.02329.91FalseNoneNoneFalseNoneFalse31677.95820
278118488711Nonecode219Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm252.8252.8145.85FalseNoneNoneFalseNoneFalse36870.880
278118588711Nonecode220Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-incharge. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm109.39109.3910.65FalseNoneNoneFalseNoneFalse1165.00350
278118688711Nonecode221Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge. Fourth floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm49.8349.8318.9FalseNoneNoneFalseNoneFalse941.7870
278118788711Nonecode222Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete. up to Fourth Floor.Sqm4787.464787.4619.2FalseNoneNoneFalseNoneFalse91919.2320
278118888711Nonecode223Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi -rigid, inorganic, non-combustible fibre glass wool insulation 50 mm thick, conforming to IS: 8183 and BS: 3958 Part 5. The insulation layer shall have facing (factory bonded on surface 1 of the fibre glass insulation layer), of black non-woven fibre glass tissue of nominal thickness 0.5 mm and nominal mass not less than 60 g/m2,made of randomly oriented glass fibres distributed in a binder by a wet-lay process including fixing 1.5 mm thick solid aluminum sheet backing using, 6 mm thick cement board including SS rivets, nuts, bolts, washers etc complete. up to First floor.Sqm1898.451898.4519.2FalseNoneNoneFalseNoneFalse36450.240
278118988711Nonecode224Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in- Charge. For payment, only the actual area of glass on face 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2. (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevent Item*).“(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 K etc. . The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. up to Fourth floor.Sqm2103.862103.8619.2FalseNoneNoneFalseNoneFalse40394.1120
278119088711Nonecode225Providing and fixing of clay tiles for cladding tiles of size 230x75x10mm thick on 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) & jointed with Adhesive/cement slurry over rough plaster surface excluding cost of rough plastered surface and the surface is painted with red apex paint and black apex paint into the groves. The work includes cost of all materials, labour charges for all items of work, usage charges for equipment, etc., complete as per specification. up to Fourth floor.Sqm2253.352253.353.3FalseNoneNoneFalseNoneFalse7436.0550
278119188711Nonecode226Providing and laying in position Reinforced cement concrete for all Super structures ofbuilding , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - Terrace Floor Works complete with all lead and lift as per the direction of Engineer-In-ChargeCum7518.467518.4622.75FalseNoneNoneFalseNoneFalse171044.9650
278119288711Nonecode227Providing, fixing and removing of formwork, Centering, shuttering and scaffolding for column. Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum5262.935262.936.03FalseNoneNoneFalseNoneFalse31735.46790
278119388711Nonecode228Providing, fixing and removing of formwork, Centering, shuttering and scaffolding (of Item No 32) for beam & lintels. Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum4511.084511.087.46FalseNoneNoneFalseNoneFalse33652.65680
278119488711Nonecode229Providing, fixing and removing of formwork, Centering, shuttering and scaffolding (of Item No 32) for slab & staircase. Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum3759.233759.239.25FalseNoneNoneFalseNoneFalse34772.87750
278119588711Nonecode230Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeKg100.88100.882568.21FalseNoneNoneFalseNoneFalse259081.02480
278119688711Nonecode231Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm159.22159.22165.92FalseNoneNoneFalseNoneFalse26417.78240
278119788711Nonecode232Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding for works Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeKg159.22159.22138.6FalseNoneNoneFalseNoneFalse22067.8920
278119888711Nonecode233Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) -Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm8799.58799.56.6FalseNoneNoneFalseNoneFalse58076.70
278119988711Nonecode234Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeCum109863.55109863.550.07FalseNoneNoneFalseNoneFalse7690.44850
278120088711Nonecode235Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. do- 30 mm thick both side commercial. Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm3206.233206.232.52FalseNoneNoneFalseNoneFalse8079.69960
278120188711Nonecode236Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos132.48132.481.0FalseNoneNoneFalseNoneFalse132.480
278120288711Nonecode237Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos1069.551069.551.0FalseNoneNoneFalseNoneFalse1069.550
278120388711Nonecode238Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos1011.211011.211.0FalseNoneNoneFalseNoneFalse1011.210
278120488711Nonecode239Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos212.7212.72.0FalseNoneNoneFalseNoneFalse425.40
278120588711Nonecode240Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90mm Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeNos99.6699.663.0FalseNoneNoneFalseNoneFalse298.980
278120688711Nonecode241Providing and fixing bright finished brass tower bolts(barrel type) with necessary screws etc. complete : 250x10mm, Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeEach409.59409.593.0FalseNoneNoneFalseNoneFalse1228.770
278120788711Nonecode242Providing 12 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners with chicken mesh all around the wall with smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm258.88258.8856.83FalseNoneNoneFalseNoneFalse14712.15040
278120888711Nonecode243Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-incharge for works Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm301.42301.42147.83FalseNoneNoneFalseNoneFalse44558.91860
278120988711Nonecode244Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm100.88100.88204.66FalseNoneNoneFalseNoneFalse20646.10080
278121088711Nonecode245Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm373.13373.13378.65FalseNoneNoneFalseNoneFalse141285.67450
278121188711Nonecode246Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer in- Charge. Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeKg134.91134.91990.0FalseNoneNoneFalseNoneFalse133560.90
278121288711Nonecode247Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Terrace floorcomplete with all lead and lift as per the direction of Engineer-In-ChargeSqm48.6248.62204.66FalseNoneNoneFalseNoneFalse9950.56920
278121388711Nonecode248Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm96.0296.02204.66FalseNoneNoneFalseNoneFalse19651.45320
278121488711Nonecode249Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm252.8252.8378.65FalseNoneNoneFalseNoneFalse95722.720
278121588711Nonecode250Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-incharge. Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm109.39109.397.15FalseNoneNoneFalseNoneFalse782.13850
278121688711Nonecode251Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge. Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm49.8349.832.52FalseNoneNoneFalseNoneFalse125.57160
278121788711Nonecode252Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace / Chajjas / Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction ofthe Engineer In charge. - Terrace floorcomplete with all lead and lift as per the direction of Engineer-In-ChargeSqm950.75950.75345.6FalseNoneNoneFalseNoneFalse328579.20
278121888711Nonecode253Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) greater than 78, solar reflection greater than 0.70 and initial emittance greater than 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner as per direction of incharge.-Terrace floor complete with all lead and lift as per the direction of Engineer-In-ChargeSqm1360.781360.78234.0FalseNoneNoneFalseNoneFalse318422.520
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17086724940000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17086724940000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17086724940000NoneNoneELIGIBILITYALL TERMS & CONDITIONS APPLY AS PER THE TENDER DOCUMENTNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 50%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (50% of estimated cost of tender)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Satisfactorily completed Work Certificate
NoneNoneNoneNoneALL TERMS & CONDITIONS APPLY AS PER THE TENDER DOCUMENTOthersALL TERMS & CONDITIONS APPLY AS PER THE TENDER DOCUMENT
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- ALL TERMS & CONDITIONS APPLY AS PER THE TENDER DOCUMENT
NoneNoneNoneNoneESI and EPF CertificateOthersESI and EPF Certificate
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneValid ESI certificate
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateFalseTechnical Bid
PWD Class I Contractor CertificateTrueTechnical Bid
GST PAN ESI PFTrueTechnical Bid
Tenderer has to upload all qualifying documents as mentioned in tender booklet and also should upload dully filled and signed tender booklet if not tenderer will be rejected AND ATTESTED BY NotaryTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1708674277000
version0
createdDateNone
modifiedDateNone
blockNumberBOARD ROOM,MANDYA MILK UNION,GEJJALAGERE,
streetNone
cityMADDUR
stateKarnataka
pin571428
tenderRecallDTONone