| 1708427467000 | 0 | None | None | Water supply/sewage lines | Providing and laying pipeline in Ward No1 and laying GI Pipeline and construction of Chambers in Ward No.5 in Nidagundi Town | 101891.08 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 2717853 | 85733 | None | code01 | Earth work excavation by manual means for drains,canals, waste weir,draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost oflabour, tools & other appurtenaces required to complete the work.In all kinds of soils Depth upto 1.5 m (PWD SR 2023-24 vol 1 P No. 5 It No 1.4.1) | Cum | 249.26 | 249.26 | 36.99 | False | None | None | False | None | False | 9220.1274 | 0 | | 2717854 | 85733 | None | code02 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing, and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with, all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for PVC pipes 90mm dia., 6 kg/sqcm & class 3 (PWD SR 2023-24 vol-5 P.no-113 I.no- 10.1.6 ) I.no- 1.60 | m | 302.82 | 302.82 | 62.0 | False | None | None | False | None | False | 18774.84 | 0 | | 2717855 | 85733 | None | code03 | Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of ductile iron (DI) conforming to IS 1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 only. The stem sealing should be with toroidal sealing rings (minimum 2 “ O “ rings). Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.) For PN-10: For Sluice Valve of PN10.0 and 100mm (PWD SR 2023-24 vol-5 P.no-22 I.no- 2.23.3) | Each | 11210.52 | 11210.52 | 1.0 | False | None | None | False | None | False | 11210.52 | 0 | | 2717856 | 85733 | None | code04 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications (PWD SR 2023-24 VOL-1 Page No- 7 I.N-1.1) | Cum | 164.8 | 164.8 | 34.88 | False | None | None | False | None | False | 5748.224 | 0 | | 2717857 | 85733 | None | code05 | Providing ,Laying and fixing of GI Pipes confirming to IS 1239:1990 with latest ammendments complete with GI fittings ( Excluding the cost of fittings) with cuts and threads wherever necessary , including testing for water tightness , with all lead and commissioning , ( Contractor will make his own arrangements for procurring water for testing ). 65mm dia For heavy duty GI Pipe etc.complete. (PWD SR 2023-24 vol-5 P.no-127 I.no- 11.3.7) | m | 859.02 | 859.02 | 20.0 | False | None | None | False | None | False | 17180.4 | 0 | | 2717858 | 85733 | None | code06 | Providing wrought mild steel (Galvanised) GI Collar confirming to IS 1239-II, 1991 With latest ammendments for 65mm dia GI Collar (PWD SR 2023-24 vol-5 P.no-129 I.no- 11.6.7) | No | 321.36 | 321.36 | 3.0 | False | None | None | False | None | False | 964.08 | 0 | | 2717859 | 85733 | None | code07 | Constructing Brick Masonry Chamber of internal Dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD75 in ceement mortar 1:6, bed concrete 150mm thick with cement 1:3:6, plastering 12mm thick with cement mortar 1:4, CC 1:2:4 copping 75mm thick for fixing CI cover & Frame etc.excluding cost of CI frame and cover.(PWD SR 2023-24 vol-5 P.no-191 I.no- 16.9). | Each | 5617.62 | 5617.62 | 5.0 | False | None | None | False | None | False | 28088.1 | 0 | | 2717860 | 85733 | None | code08 | Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of ductile iron (DI) conforming to IS 1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 only. The stem sealing should be with toroidal sealing rings (minimum 2 “ O “ rings). Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.) For PN-10: For Sluice Valve of PN10.0 and 80mm (PWD SR 2023-24 vol-5 P.no-22 I.no- 2.23.2) | Each | 10704.79 | 10704.79 | 1.0 | False | None | None | False | None | False | 10704.79 | 0 |
|