2787691 | 89097 | None | code01 | Demolishing cement concrete manually/ by mechanical means includingdisposal of material to the appropriate disposal area as per direction of Engineer-in-charge. | Cum | 1712.89 | 1712.89 | 14.44 | False | None | None | False | None | False | 24734.1316 | 0 |
2787692 | 89097 | None | code02 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work | Cum | 105.06 | 105.06 | 78.16 | False | None | None | False | None | False | 8211.4896 | 0 |
2787693 | 89097 | None | code03 | Providing and Filling in foundation with granite / trap broken metal 100mm. And down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications. | Cum | 2762.46 | 2762.46 | 8.0 | False | None | None | False | None | False | 22099.68 | 0 |
2787694 | 89097 | None | code04 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately Mix 1:4:8Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5833.92 | 5833.92 | 6.0 | False | None | None | False | None | False | 35003.52 | 0 |
2787695 | 89097 | None | code05 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand ) | Cum | 6580.67 | 6580.67 | 18.05 | False | None | None | False | None | False | 118781.0935 | 0 |
2787696 | 89097 | None | code06 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. excluding cost of steel reinforcement & including cost of centerinf scaffolding and formwork M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for footing | Cum | 7048.17 | 7048.17 | 20.05 | False | None | None | False | None | False | 141315.8085 | 0 |
2787697 | 89097 | None | code07 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10572.44 | 10572.44 | 6.5 | False | None | None | False | None | False | 68720.86 | 0 |
2787698 | 89097 | None | code08 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11982.09 | 11982.09 | 3.78 | False | None | None | False | None | False | 45292.3002 | 0 |
2787699 | 89097 | None | code09 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Excluding cost of steel reinforcement, dowel bars & including centering,scaffolding, formwork M25Design Mix Using 20 mm nominal size graded crushed coarse aggregates For roof slab | Cum | 11982.09 | 11982.09 | 9.9 | False | None | None | False | None | False | 118622.691 | 0 |
2787700 | 89097 | None | code10 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Excluding cost of steel reinforcement, dowel bars & including centering,scaffolding, formwork M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Chejja | Cum | 10220.02 | 10220.02 | 0.79 | False | None | None | False | None | False | 8073.8158 | 0 |
2787701 | 89097 | None | code11 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Buildings | Tonne | 92140.71 | 92140.71 | 1.89 | False | None | None | False | None | False | 174145.9419 | 0 |
2787702 | 89097 | None | code12 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.. (P 7/1.9/V-1) | Cum | 273.98 | 273.98 | 69.98 | False | None | None | False | None | False | 19173.1204 | 0 |
2787703 | 89097 | None | code13 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge to the ppropriate disposal area. | Cum | 374.92 | 374.92 | 19.44 | False | None | None | False | None | False | 7288.4448 | 0 |
2787704 | 89097 | None | code14 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour, rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 488.22 | 488.22 | 13.52 | False | None | None | False | None | False | 6600.7344 | 0 |
2787705 | 89097 | None | code15 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6403.51 | 6403.51 | 6.76 | False | None | None | False | None | False | 43287.7276 | 0 |
2787706 | 89097 | None | code16 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1349.3 | 1349.3 | 83.45 | False | None | None | False | None | False | 112599.085 | 0 |
2787707 | 89097 | None | code17 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1267.93 | 1267.93 | 19.25 | False | None | None | False | None | False | 24407.6525 | 0 |
2787708 | 89097 | None | code18 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications | Cum | 101779.45 | 101779.45 | 0.15 | False | None | None | False | None | False | 15266.9175 | 0 |
2787709 | 89097 | None | code19 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. | Nos | 1046.48 | 1046.48 | 2.0 | False | None | None | False | None | False | 2092.96 | 0 |
2787710 | 89097 | None | code20 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. 35 mm thick one side teak and one side commercial | Sqm | 4013.91 | 4013.91 | 5.04 | False | None | None | False | None | False | 20230.1064 | 0 |
2787711 | 89097 | None | code21 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame | Mtr | 662.29 | 662.29 | 15.15 | False | None | None | False | None | False | 10033.6935 | 0 |
2787712 | 89097 | None | code22 | Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames.30mm thickness | Sqm | 3300.12 | 3300.12 | 5.36 | False | None | None | False | None | False | 17688.6432 | 0 |
2787713 | 89097 | None | code23 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kg | 173.04 | 173.04 | 209.25 | False | None | None | False | None | False | 36208.62 | 0 |
2787714 | 89097 | None | code24 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 262.65 | 262.65 | 45.65 | False | None | None | False | None | False | 11989.9725 | 0 |
2787715 | 89097 | None | code25 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 100mm wide | Mtr | 45.32 | 45.32 | 273.8 | False | None | None | False | None | False | 12408.616 | 0 |
2787716 | 89097 | None | code26 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 287.37 | 287.37 | 139.28 | False | None | None | False | None | False | 40024.8936 | 0 |
2787717 | 89097 | None | code27 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 342.99 | 342.99 | 158.75 | False | None | None | False | None | False | 54449.6625 | 0 |
2787718 | 89097 | None | code28 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth. | Mtr | 67.98 | 67.98 | 273.8 | False | None | None | False | None | False | 18612.924 | 0 |
2787719 | 89097 | None | code29 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. size of tile 600x600mm | Sqm | 1179.35 | 1179.35 | 30.19 | False | None | None | False | None | False | 35604.5765 | 0 |
2787720 | 89097 | None | code30 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with whitecement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :** Flamed finish granite stone slab Black, Cat Eye, River Pink or equivalent. | Sqm | 2539.98 | 2539.98 | 12.35 | False | None | None | False | None | False | 31368.753 | 0 |
2787721 | 89097 | None | code31 | Providing and fixing 1st quality ceramic glazed floor tiles conforming toIS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2 including pointing in white cement mixed with pigment of matching shade complete | Sqm | 1139.18 | 1139.18 | 6.75 | False | None | None | False | None | False | 7689.465 | 0 |
2787722 | 89097 | None | code32 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg/m2, including pointing in white cement mixed with pigment of matching shade complete. | Sqm | 1139.18 | 1139.18 | 49.17 | False | None | None | False | None | False | 56013.4806 | 0 |
2787723 | 89097 | None | code33 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 103.0 | 103.0 | 184.93 | False | None | None | False | None | False | 19047.79 | 0 |
2787724 | 89097 | None | code34 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 171.6 | 171.6 | 184.93 | False | None | None | False | None | False | 31733.988 | 0 |
2787725 | 89097 | None | code35 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 179.22 | 179.22 | 181.25 | False | None | None | False | None | False | 32483.625 | 0 |
2787726 | 89097 | None | code36 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. 6 Kg/m2: 110mm(weight of pipe -1.894 kg) | m | 368.74 | 368.74 | 19.0 | False | None | None | False | None | False | 7006.06 | 0 |
2787727 | 89097 | None | code37 | Providing and fixing chorinated poly vinyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. (external work).(V2 item no 13.33.3) (Crri-01) 25mm nominal OD pipes m | Mtr | 304.88 | 304.88 | 30.0 | False | None | None | False | None | False | 9146.4 | 0 |
2787728 | 89097 | None | code38 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete. (Concealed work including cutting chases and good the walls etc.(V2 item no 13.32.2) (Crri-01)20mm Dia | Mtr | 390.37 | 390.37 | 25.0 | False | None | None | False | None | False | 9759.25 | 0 |
2787729 | 89097 | None | code39 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. 75mm ( weight of pipe -0.917 kg) | Mtr | 197.76 | 197.76 | 4.0 | False | None | None | False | None | False | 791.04 | 0 |
2787730 | 89097 | None | code40 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. 90mm ( weight of pipe -1.313 kg) | Mtr | 265.74 | 265.74 | 10.0 | False | None | None | False | None | False | 2657.4 | 0 |
2787731 | 89097 | None | code41 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. 160mm ( weight of pipe -3.923 kg) | Mtr | 665.38 | 665.38 | 115.0 | False | None | None | False | None | False | 76518.7 | 0 |
2787732 | 89097 | None | code42 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. | Nos | 5617.62 | 5617.62 | 13.0 | False | None | None | False | None | False | 73029.06 | 0 |
2787733 | 89097 | None | code43 | Providing and fixing SFRC frame and cover conforming to IS 12592 (part-I)-1988 and IS 12592 (part-II)- 1991 with latest amendment,including cutting slabs to the required size for the opening and fixing the cover in C.C. 1:2:4 and C.M. 1:3 plastering 20 mm thick to all exposed faces, curing for 10 days with all lead and lift with appurtenances. complete .Heavy Duty | Nos | 2640.92 | 2640.92 | 13.0 | False | None | None | False | None | False | 34331.96 | 0 |
2787734 | 89097 | None | code44 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 14.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests Vol- 2 P-123/14.1.1. | Nos | 5030.52 | 5030.52 | 1.0 | False | None | None | False | None | False | 5030.52 | 0 |
2787735 | 89097 | None | code45 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid | Nos | 6156.31 | 6156.31 | 1.0 | False | None | None | False | None | False | 6156.31 | 0 |
2787736 | 89097 | None | code46 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer | Nos | 4244.63 | 4244.63 | 2.0 | False | None | None | False | None | False | 8489.26 | 0 |
2787737 | 89097 | None | code47 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Circular shape 450 mm dia | Nos | 1120.64 | 1120.64 | 2.0 | False | None | None | False | None | False | 2241.28 | 0 |
2787738 | 89097 | None | code48 | Providing and fixing 100 mm sand cast Iron grating for gully trap. | Nos | 48.41 | 48.41 | 2.0 | False | None | None | False | None | False | 96.82 | 0 |
2787739 | 89097 | None | code49 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 g. | Nos | 871.38 | 871.38 | 5.0 | False | None | None | False | None | False | 4356.9 | 0 |
2787740 | 89097 | None | code50 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 | Nos | 638.6 | 638.6 | 5.0 | False | None | None | False | None | False | 3193.0 | 0 |
2787741 | 89097 | None | code51 | Providing and fixing Side operated Single lever wall mixer with L shaped Tubular bend set for overhead shower made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - (wall mixer only) | Nos | 8371.84 | 8371.84 | 1.0 | False | None | None | False | None | False | 8371.84 | 0 |
2787742 | 89097 | None | code52 | Providing and fixing Overhead rain showers of minimum dimension 225x225mm & wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class a Economy Vol- 2 P-143/14.81 | Nos | 1113.43 | 1113.43 | 1.0 | False | None | None | False | None | False | 1113.43 | 0 |
2787743 | 89097 | None | code53 | Providing and fixing Towel rail 600mm length made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class | Nos | 1299.86 | 1299.86 | 1.0 | False | None | None | False | None | False | 1299.86 | 0 |
2787744 | 89097 | None | code54 | Providing and fixing Soap dish wired with 200mm width made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class | Nos | 739.54 | 739.54 | 1.0 | False | None | None | False | None | False | 739.54 | 0 |
2787745 | 89097 | None | code55 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Vol-123 P-42/13.34 | Ltr | 9.27 | 9.27 | 2000.0 | False | None | None | False | None | False | 18540.0 | 0 |
2787746 | 89097 | None | code56 | Providing and fixing Single flow hand showers with Anti lime jets with1.5m PVC tube and holder made of Stainless steel with all concealed fittingarrangements & all necessary accesories complete - Class Vol- 2 P-143/14.78 a -Economy (Health faucet) | No | 913.61 | 913.61 | 1.0 | False | None | None | False | None | False | 913.61 | 0 |
2787747 | 89097 | None | code57 | Providing & fixing of 2.5 track x 2- panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 81mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm x 57mm and mesh sash of size with GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8 - 2.0mm. Maximum possible size 1519mm x 1519mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 6747.53 | 6747.53 | 13.95 | False | None | None | False | None | False | 94128.0435 | 0 |
2787748 | 89097 | None | code58 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Kgs | 142.14 | 142.14 | 129.0 | False | None | None | False | None | False | 18336.06 | 0 |
2787749 | 89097 | None | code59 | Developmental works :- Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc 20 mm nominal dia pipes | Mtr | 380.14 | 380.14 | 15.0 | False | None | None | False | None | False | 5702.1 | 0 |
2787750 | 89097 | None | code60 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc 25 mm nominal dia pipes | Mtr | 491.31 | 491.31 | 40.0 | False | None | None | False | None | False | 19652.4 | 0 |
2787751 | 89097 | None | code61 | Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete.Heavy Duty GI pipe of 20mm dia | Mtr | 270.89 | 270.89 | 70.0 | False | None | None | False | None | False | 18962.3 | 0 |
2787752 | 89097 | None | code62 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 510x1040 mm bowl depth 250 mm | No | 5786.54 | 5786.54 | 1.0 | False | None | None | False | None | False | 5786.54 | 0 |
2787753 | 89097 | None | code63 | Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications | Sqm | 1433.76 | 1433.76 | 3.0 | False | None | None | False | None | False | 4301.28 | 0 |
2787754 | 89097 | None | code64 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.32 mm dia | No | 211.15 | 211.15 | 8.0 | False | None | None | False | None | False | 1689.2 | 0 |
2787755 | 89097 | None | code65 | Providing and fixing HealthFawset | No | 1000.0 | 1000.0 | 4.0 | False | None | None | False | None | False | 4000.0 | 0 |
2787756 | 89097 | None | code66 | Providing and fixing Push cock for urinals | No | 800.0 | 800.0 | 5.0 | False | None | None | False | None | False | 4000.0 | 0 |
2787757 | 89097 | None | code67 | Providing and fixing Flushing cistren | No | 800.0 | 800.0 | 2.0 | False | None | None | False | None | False | 1600.0 | 0 |
2787758 | 89097 | None | code68 | Providing and fixing Taps | No | 600.0 | 600.0 | 4.0 | False | None | None | False | None | False | 2400.0 | 0 |
2787759 | 89097 | None | code69 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. 2.4 (i) By Manual Means a In area of light jungle | Sqm | 11.56 | 11.56 | 2000.0 | False | None | None | False | None | False | 23120.0 | 0 |
2787760 | 89097 | None | code70 | Cutting of Trees, excluding removal of stumps and roots of trees Girth from 300 mm to 600 mm | No | 612.85 | 612.85 | 7.0 | False | None | None | False | None | False | 4289.95 | 0 |
2787761 | 89097 | None | code71 | Removal of stumps and roots including backfilling with suitable material to required compaction Girth from 300 mm to 600 mm | No | 366.68 | 366.68 | 10.0 | False | None | None | False | None | False | 3666.8 | 0 |
2787762 | 89097 | None | code72 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. SRP no 41/8.3.1 2023-24 vol ii | Sqm | 135.96 | 135.96 | 500.0 | False | None | None | False | None | False | 67980.0 | 0 |
2787763 | 89097 | None | code73 | 8.39 Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 130.81 | 130.81 | 500.0 | False | None | None | False | None | False | 65405.0 | 0 |
2787764 | 89097 | None | code74 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. SRP no 48/8.40 2023-24 vol ii | Sqm | 92.7 | 92.7 | 200.0 | False | None | None | False | None | False | 18540.0 | 0 |
2787765 | 89097 | None | code75 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead Dismantling Brick / Tile work In cement mortar | Cum | 513.97 | 513.97 | 10.0 | False | None | None | False | None | False | 5139.7 | 0 |
2787766 | 89097 | None | code76 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. 1.5.1 In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 307.97 | 307.97 | 15.0 | False | None | None | False | None | False | 4619.55 | 0 |
2787767 | 89097 | None | code77 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. 2.1.2 Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6006.96 | 6006.96 | 10.0 | False | None | None | False | None | False | 60069.6 | 0 |
2787768 | 89097 | None | code78 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) 2.2.1.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse agreegates | Cum | 6417.93 | 6417.93 | 6.91 | False | None | None | False | None | False | 44347.8963 | 0 |
2787769 | 89097 | None | code79 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specification | Sqm | 1267.93 | 1267.93 | 50.0 | False | None | None | False | None | False | 63396.5 | 0 |
2787770 | 89097 | None | code80 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 148.0 | 148.0 | 4.0 | False | None | None | False | None | False | 592.0 | 0 |
2787771 | 89097 | None | code81 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 40 mm nominal dia Pipes | Mtr | 589.6 | 589.6 | 50.0 | False | None | None | False | None | False | 29480.0 | 0 |
2787772 | 89097 | None | code82 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications,includingcostoflabour,rolling,water,allmaterials,usage& all other appurtenaces required tocomplete the work.vol - 1 P- 7/1.8 | Cum | 488.22 | 488.22 | 248.8 | False | None | None | False | None | False | 121469.136 | 0 |
2787773 | 89097 | None | code83 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. vol - 3 P - 26/4.17 23-24 SR | Cum | 2635.77 | 2635.77 | 248.8 | False | None | None | False | None | False | 655779.576 | 0 |
2787774 | 89097 | None | code84 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machinemixed with super plasticizers laid in finished layers, well compactedusing needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the otherappurtenancesrequired to complete the work as per technical specifications. (The costof steel reinforcement & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse vol - 1 P- 15/2.2.2.1 | Cum | 6905.12 | 6905.12 | 5.0 | False | None | None | False | None | False | 34525.6 | 0 |
2787775 | 89097 | None | code85 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3and minimumcompressive strength of 4.00 N/mm2 conforming to IS2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005including cost of allmaterials, labour, scaffolding and curing, usagecharges of machinery etc complete as per specifications.P-17/6.32 of vol - 2 | Sqm | 1349.3 | 1349.3 | 60.0 | False | None | None | False | None | False | 80958.0 | 0 |
2787776 | 89097 | None | code86 | Painting with synthetic enamel paint of approved brand andmanufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paintof approved brand and manufacture after thoroughly brooming thesurface to remove all dirt, dust, mortar drops and foreign matterincluding preparing the surface even and sand paper smooth, cost ofmaterials, labour complete as per specifications and as per directionsof Engineer-in-charge.P-48/8.41 of Vol - 2 | Sqm | 172.01 | 172.01 | 330.0 | False | None | None | False | None | False | 56763.3 | 0 |
2787777 | 89097 | None | code87 | Providing and fixing Structural Steel work riveted, bolted or weldedin built up sections, trusses and framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steelprimer all complete including cost of materials, labour, usage chargesof machinery complete as per specifications and as per directions ofthe Engineer-in-Charge.P-75/11.2 of Vol - 2 | Kgs | 105.06 | 105.06 | 2000.0 | False | None | None | False | None | False | 210120.0 | 0 |
2787778 | 89097 | None | code88 | Disposal of building rubbish / malba / similar unserviceable, dismantledorwaste materials by mechanical means, including loading, transporting,unloading to approved municipal dumping ground or as approved byEngineer-in-charge to the appropriate disposal area.vol- 2p P - 193/19.59 | Cum | 374.92 | 374.92 | 50.0 | False | None | None | False | None | False | 18746.0 | 0 |
2787779 | 89097 | None | code89 | Providing Thermo-Mechanically Treated bars of grade Fe-500D ormore Steel reinforcement for R.C.C. work including straightening,cutting, bending, placing in position, binding and anchoring to adjacentmembers whereever necessary complete as per Design including costof material, labour, usage charges complete as per specifications. (Thelaps and wastages shall not be measured separately. P-84/11.32 Vol -3 | Quintal | 9476.0 | 9476.0 | 14.29 | False | None | None | False | None | False | 135412.04 | 0 |
2787780 | 89097 | None | code90 | Providing and fixing Radial exuaster at terrace of Repair bays building | No | 7000.0 | 7000.0 | 1.0 | False | None | None | False | None | False | 7000.0 | 0 |
2787781 | 89097 | None | code91 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheetand polyester top coat 15-18 microns. Sheet should have protective guardfilm of 25 microns minimum to avoid scratches during transportation andshould be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws ofsize (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trussesand including cutting to size and shape wherever required.P-26/7.38 of vol 2 | Sqm | 585.04 | 585.04 | 27.6 | False | None | None | False | None | False | 16147.104 | 0 |
2787782 | 89097 | None | code92 | Electrical Works:- Open Conduit System: Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 19/20 mm dia 2 mm thick 1.1.1 | Mtr | 71.07 | 71.07 | 60.0 | False | None | None | False | None | False | 4264.2 | 0 |
2787783 | 89097 | None | code93 | Do- 25 mm dia 2 mm thick 1.1.2 | Mtr | 83.43 | 83.43 | 40.0 | False | None | None | False | None | False | 3337.2 | 0 |
2787784 | 89097 | None | code94 | Concealed Conduit System: Supplying heavy gauge PVC conduit pipe mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20 mm dia 2
mm thick 1.2.1 | Mtr | 67.98 | 67.98 | 100.0 | False | None | None | False | None | False | 6798.0 | 0 |
2787785 | 89097 | None | code95 | 25 mm dia 2 mm thick 1.2.2 | Mtr | 80.34 | 80.34 | 50.0 | False | None | None | False | None | False | 4017.0 | 0 |
2787786 | 89097 | None | code96 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 19/20 mm
dia 2 mm thick 1.3.1 | Mtr | 70.04 | 70.04 | 20.0 | False | None | None | False | None | False | 1400.8 | 0 |
2787787 | 89097 | None | code97 | Do- 25 mm dia 2 mm thick 1.3.2 | Mtr | 81.37 | 81.37 | 50.0 | False | None | None | False | None | False | 4068.5 | 0 |
2787788 | 89097 | None | code98 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm as required. 25 mm 1.8.2 | Mtr | 36.05 | 36.05 | 150.0 | False | None | None | False | None | False | 5407.5 | 0 |
2787789 | 89097 | None | code99 | Supplying PVC flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe
terminated completely. 20 mm 1.9.1 | Mtr | 19.57 | 19.57 | 10.0 | False | None | None | False | None | False | 195.7 | 0 |
2787790 | 89097 | None | code100 | Do- 25 mm 1.9.2 | Mtr | 22.66 | 22.66 | 10.0 | False | None | None | False | None | False | 226.6 | 0 |
2787791 | 89097 | None | code101 | Supplying And Fixing Metal Fan Box with Round Hook. | No | 120.51 | 120.51 | 6.0 | False | None | None | False | None | False | 723.06 | 0 |
2787792 | 89097 | None | code102 | Supplying and wiring adopting loop system in existing PVC Conduit / casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box 2.2.1 | Point | 277.07 | 277.07 | 8.0 | False | None | None | False | None | False | 2216.56 | 0 |
2787793 | 89097 | None | code103 | Do- Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box 2.2.2 | Point | 390.37 | 390.37 | 12.0 | False | None | None | False | None | False | 4684.44 | 0 |
2787794 | 89097 | None | code104 | Do- Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box 2.2.3 | Point | 571.65 | 571.65 | 12.0 | False | None | None | False | None | False | 6859.8 | 0 |
2787795 | 89097 | None | code105 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:2010 1.5 mm2 2.3.2 | Mtr | 26.78 | 26.78 | 150.0 | False | None | None | False | None | False | 4017.0 | 0 |
2787796 | 89097 | None | code106 | Do- 2.5 mm2 2.3.3 | Mtr | 43.26 | 43.26 | 250.0 | False | None | None | False | None | False | 10815.0 | 0 |
2787797 | 89097 | None | code107 | Do- 4 mm2 2.3.4 | Mtr | 64.89 | 64.89 | 100.0 | False | None | None | False | None | False | 6489.0 | 0 |
2787798 | 89097 | None | code108 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 1-2 Way 3.3.1 | No | 106.09 | 106.09 | 10.0 | False | None | None | False | None | False | 1060.9 | 0 |
2787799 | 89097 | None | code109 | Do- 6 Way 3.3.4 | No | 178.19 | 178.19 | 3.0 | False | None | None | False | None | False | 534.57 | 0 |
2787800 | 89097 | None | code110 | Do- 8 Way 3.3.5 | No | 225.57 | 225.57 | 3.0 | False | None | None | False | None | False | 676.71 | 0 |
2787801 | 89097 | None | code111 | Do- 10-12 Way 3.3.6 | No | 268.83 | 268.83 | 10.0 | False | None | None | False | None | False | 2688.3 | 0 |
2787802 | 89097 | None | code112 | Do- 18 Way 3.3.8 | No | 349.17 | 349.17 | 2.0 | False | None | None | False | None | False | 698.34 | 0 |
2787803 | 89097 | None | code113 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-2 Way 3.4.1 | No | 142.14 | 142.14 | 2.0 | False | None | None | False | None | False | 284.28 | 0 |
2787804 | 89097 | None | code114 | Do- 6 Way 3.4.4 | No | 226.6 | 226.6 | 2.0 | False | None | None | False | None | False | 453.2 | 0 |
2787805 | 89097 | None | code115 | Do- 8 Way 3.4.5 | No | 268.83 | 268.83 | 4.0 | False | None | None | False | None | False | 1075.32 | 0 |
2787806 | 89097 | None | code116 | Do- 10-12 Way 3.4.6 | No | 328.57 | 328.57 | 2.0 | False | None | None | False | None | False | 657.14 | 0 |
2787807 | 89097 | None | code117 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module 3.5.1 | No | 141.11 | 141.11 | 12.0 | False | None | None | False | None | False | 1693.32 | 0 |
2787808 | 89097 | None | code118 | Do- 6 Module 3.5.4 | No | 241.02 | 241.02 | 5.0 | False | None | None | False | None | False | 1205.1 | 0 |
2787809 | 89097 | None | code119 | Do- 8 Module 3.5.5 | No | 292.52 | 292.52 | 7.0 | False | None | None | False | None | False | 2047.64 | 0 |
2787810 | 89097 | None | code120 | Do- 10-12 Module 3.5.6 | No | 354.32 | 354.32 | 12.0 | False | None | None | False | None | False | 4251.84 | 0 |
2787811 | 89097 | None | code121 | Do- 18 Module 3.5.8 | No | 470.71 | 470.71 | 2.0 | False | None | None | False | None | False | 941.42 | 0 |
2787812 | 89097 | None | code122 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch 3.6.1 | No | 105.06 | 105.06 | 70.0 | False | None | None | False | None | False | 7354.2 | 0 |
2787813 | 89097 | None | code123 | Do- 6A Three Way socket 3.6.3 | No | 176.13 | 176.13 | 40.0 | False | None | None | False | None | False | 7045.2 | 0 |
2787814 | 89097 | None | code124 | Do- Stepped Fan Regulator Two Module 3.6.4 | No | 367.71 | 367.71 | 10.0 | False | None | None | False | None | False | 3677.1 | 0 |
2787815 | 89097 | None | code125 | Do- 32A DP Switch 3.6.9 | No | 335.78 | 335.78 | 4.0 | False | None | None | False | None | False | 1343.12 | 0 |
2787816 | 89097 | None | code126 | Do- 6/16A Universal Socket 3.6.10 | No | 243.08 | 243.08 | 4.0 | False | None | None | False | None | False | 972.32 | 0 |
2787817 | 89097 | None | code127 | Do- TV/Telephone Socket 3.6.11 | No | 160.68 | 160.68 | 2.0 | False | None | None | False | None | False | 321.36 | 0 |
2787818 | 89097 | None | code128 | Do- RJ45/I.O Outlet Cat-6 3.6.12 | No | 347.11 | 347.11 | 10.0 | False | None | None | False | None | False | 3471.1 | 0 |
2787819 | 89097 | None | code129 | Supplying and fixing of metal clad industrial plugs and sockets. 2pole+earth 250V PLUG 32A 3.13.2 | No | 564.52 | 564.52 | 4.0 | False | None | None | False | None | False | 2258.08 | 0 |
2787820 | 89097 | None | code130 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP 5.18.1 | No | 427.45 | 427.45 | 6.0 | False | None | None | False | None | False | 2564.7 | 0 |
2787821 | 89097 | None | code131 | Do- 6-32 A DP 5.18.4 | No | 761.17 | 761.17 | 6.0 | False | None | None | False | None | False | 4567.02 | 0 |
2787822 | 89097 | None | code132 | Do- 6-32 A TPN 5.18.7 | No | 1768.51 | 1768.51 | 2.0 | False | None | None | False | None | False | 3537.02 | 0 |
2787823 | 89097 | None | code133 | Do- 40 A TPN 5.18.8 | No | 3135.32 | 3135.32 | 2.0 | False | None | None | False | None | False | 6270.64 | 0 |
2787824 | 89097 | None | code134 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. II - Double Door 8 Way SP & N 5.19.8 | No | 1909.62 | 1909.62 | 2.0 | False | None | None | False | None | False | 3819.24 | 0 |
2787825 | 89097 | None | code135 | Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 12" Sweep (300 mm) 6.2.1 | No | 3058.07 | 3058.07 | 2.0 | False | None | None | False | None | False | 6116.14 | 0 |
2787826 | 89097 | None | code136 | Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire. 13.14 | No | 506.76 | 506.76 | 2.0 | False | None | None | False | None | False | 1013.52 | 0 |
2787827 | 89097 | None | code137 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48" Sweep (1200 mm) Regular model 6.3.1 | No | 3073.52 | 3073.52 | 12.0 | False | None | None | False | None | False | 36882.24 | 0 |
2787828 | 89097 | None | code138 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. 13.10 | No | 176.13 | 176.13 | 12.0 | False | None | None | False | None | False | 2113.56 | 0 |
2787829 | 89097 | None | code139 | Supplying vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside Fiber body outside, filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate. 2kW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting. 5 Star With Fibre body 25 L 7.2.1 | No | 12286.87 | 12286.87 | 2.0 | False | None | None | False | None | False | 24573.74 | 0 |
2787830 | 89097 | None | code140 | Erection charges for fixing a wall mounting electric geysers using bolts, flat at one end nut and washers at the other end for through bolts and nuts and washers with 150x450x600mm back plate and wiring complete with 15A 3 pin top. upto 30 Litres 13.15.1 | No | 683.92 | 683.92 | 2.0 | False | None | None | False | None | False | 1367.84 | 0 |
2787831 | 89097 | None | code141 | Supplying and drawing UTP-CAT 6E LAN cable. 8.1 | m | 39.14 | 39.14 | 300.0 | False | None | None | False | None | False | 11742.0 | 0 |
2787832 | 89097 | None | code142 | Supplying fixing of 48 port 10/100 Switch 8.9.4 | No | 15450.0 | 15450.0 | 1.0 | False | None | None | False | None | False | 15450.0 | 0 |
2787833 | 89097 | None | code143 | Supplying & Fixing of ... ms Cat 6 Patch Cable. 1 m 8.11.1 | No | 230.72 | 230.72 | 14.0 | False | None | None | False | None | False | 3230.08 | 0 |
2787834 | 89097 | None | code144 | Supplying & Fixing of Patch panel for LAN cabling 48 Port 10/100 patch panel 8.12.1 | No | 14543.6 | 14543.6 | 1.0 | False | None | None | False | None | False | 14543.6 | 0 |
2787835 | 89097 | None | code145 | Supplying of .....feet -PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 W 11.3.2 | No | 710.7 | 710.7 | 20.0 | False | None | None | False | None | False | 14214.0 | 0 |
2787836 | 89097 | None | code146 | Do- LED light fitting 1 x 4' - 36/40 W 11.3.3 | No | 1307.07 | 1307.07 | 22.0 | False | None | None | False | None | False | 28755.54 | 0 |
2787837 | 89097 | None | code147 | Fixing all types and all capacities of 1'x4' / 2'x2' LED Light fittings indoor on the wall / ceiling / rafters / girders with necessary supporting frame, using 2310.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps.
13.19 | No | 180.0 | 180.0 | 42.0 | False | None | None | False | None | False | 7560.0 | 0 |
2787838 | 89097 | None | code148 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with........W System Power consumption. LED Efficiencygreater than 1301m/w, nominal CRI greater than 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under | No | 9125.8 | 9125.8 | 3.0 | False | None | None | False | None | False | 27377.4 | 0 |
2787839 | 89097 | None | code149 | Supplying and Fixing of........mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires. Using 32mm dia G.I.Pipe. 13.1.2 | No | 1076.35 | 1076.35 | 3.0 | False | None | None | False | None | False | 3229.05 | 0 |
2787840 | 89097 | None | code150 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application.
Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System Power consumption. LED Efficiencygreater than 1301m/w, nominal CRI greater than 75. Luminaire manufacturer should have in- house facility | No | 9770.58 | 9770.58 | 12.0 | False | None | None | False | None | False | 117246.96 | 0 |
2787841 | 89097 | None | code151 | Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over
existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. 13.5 | No | 166.86 | 166.86 | 12.0 | False | None | None | False | None | False | 2002.32 | 0 |
2787842 | 89097 | None | code152 | Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell 12.2.1 | No | 253.38 | 253.38 | 1.0 | False | None | None | False | None | False | 253.38 | 0 |
2787843 | 89097 | None | code153 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using
40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal
150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia. 12.56 | No | 3615.3 | 3615.3 | 1.0 | False | None | None | False | None | False | 3615.3 | 0 |
2787844 | 89097 | None | code154 | Supply and fixing GI/Copper strips for grounding connections, using necessary fixing materials as required. 25 x 6 mm GI strip 12.58.3 | Mtr | 131.84 | 131.84 | 10.0 | False | None | None | False | None | False | 1318.4 | 0 |
2787845 | 89097 | None | code155 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS- 3975 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm) 32.05 | Kms | 146097.26 | 146097.26 | 0.3 | False | None | None | False | None | False | 43829.178 | 0 |
2787846 | 89097 | None | code156 | Laying LTUG cable of 2.5 to 25 Sqmm (Single/3.5/4 Core) 20.05 | Kms | 1222.61 | 1222.61 | 0.3 | False | None | None | False | None | False | 366.783 | 0 |