createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1708678703921
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyRESERVED
invitingStrategyTextReserved
taxTypeINCLUSIVE_TAX
tenderFee2050.00
emd82000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose02-03-2024 17:00:00
tenderQueryClose29-02-2024 17:00:00
technicalBidOpen04-03-2024 11:00:00
publishedDate23-02-2024 16:20:47
publishedByPostRWSSD_EE_DIV_BID
publishedByUserKPE12515 - RAMALINGAPPA BIRADAR
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonPradeep Patil
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9538567662
tenderSupplierListNone
tenderSchedule
createdTs1708678703965
version4
createdDateNone
modifiedDateNone
tenderNumberRWSSD/2023-24/WS/WORK_INDENT7861
titleConstruction of Water Overhead Tank in Govt HPS RMSA Koundgaon and Other 49 Govt. Schools in Aurad (B) Taluka (AKSHARA AVISHKARA Work Code -BDR231231194 ,BDR231232195 &BDR231233196) Belongs to ST Category
descriptionConstruction of Water Overhead Tank in Aurad tq.at 1)Govt HPS and RMSA Koundgaon 2)Govt HPS and RMSA Hangarga 3)Govt HPS Handikera4)Govt HS Aurad B5)Govt HS Hokrana6)Govt HS Murki7)Govt HPS Santhpur8)Govt HS Ekamba9)Govt HS Torna10)Govt HS Chavar dabka11)Govt HS Kushnoor12)Govt HS Mudhol B13)Govt HS Dhupatmahagaon14)Govt HS Jambgi15)Govt HS Chintaki16)Govt HS Nagmarpalli17)Govt HS Eklar18)Govt HS Yengunda19)Govt HS Holsamudra20)Govt HPS Teacher colony Aurad21)Govt HPS Jambagi22)karnataka Public school Govt MPS Kushnoor23)Govt MPS Murki24)Govt HPS Hokrana25)Govt MPS Chavar Dabka26)Govt HPS Chintaki27)Govt MPS Wadgaon D28)Govt HPS Belkuni B29)Govt HPS Bhandarkumta30)Govt MPS Kamalnagar31)Govt HPS Yengunda32)Govt HPS Kherda B33)Govt MPS Santhpur34)Govt HPS Dhupatmahagaon35)Govt HPS chikli U36)Govt HPS Belkuni ch37)Govt HPS Wanmarpalli38)GHPS Urdu kamalnagar39)Govt HPS Bawalgaon40)Govt HPS Ganganbeed41)Govt HPS Badalgaon42)Govt HPS Chikli J43)Govt HPS Ashoknagar thanda Chintaki44)Govt HPS Kollur45)Govt HPS Sundal46)Govt HPS Holsamudra47)Govt HPS Nandi Bijalgaon48)Govt HPS Bonthi49)Govt HPS Gudpalli50)Govt LPS Hulyal (AKSHARA AVISHKARA Work Code -BDR231231194 ,BDR231232195 &BDR231233196) Belongs to ST Category
categoryWORKS
categoryTextWorks
ecv8194654.64
deptNameRural Drinking Water and Sanitation Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location1106
locationNameRWSSD Division Office Bidar
provisionalAmount9990000.0
groupOverheadTotalNone
fileNumberBDR231231194andBDR231232195andBDR231233196
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17086787040000NoneNoneWater supply/sewage linesConstruction of Water Overhead Tank in Govt HPS RMSA Koundgaon and Other 49 Govt. Schools in Aurad (B) Taluka (AKSHARA AVISHKARA Work Code -BDR231231194 ,BDR231232195 &BDR231233196)8194654.64
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
278304988837NoneKKRDBARDOHT01Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50mCum508.2508.21452.12FalseNoneNoneFalseNoneFalse737967.3840
278305088837NoneKKRDBARDOHT02Providing and fixing Chlorinated Polyvinyle Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings. Including fixing the pipe with clamps at 1m spacing this includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints as per direction of Engineer incharge-External work.Internal work-Exposed on WallMtr390.6390.67171.0FalseNoneNoneFalseNoneFalse2800992.60
278305188837NoneKKRDBARDOHT03Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specificationsCum168.0168.01452.12FalseNoneNoneFalseNoneFalse243956.160
278305288837NoneKKRDBARDOHT04Supplying of Gate value 32mm nominal bore-gun metal.No614.25614.25250.0FalseNoneNoneFalseNoneFalse153562.50
278305388837NoneKKRDBARDOHT05Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.1000 LtrLtr9.459.4550000.0FalseNoneNoneFalseNoneFalse472500.00
278305488837NoneKKRDBARDOHT06Supplying,laying,jointing ,testing and commissioning of G.I. Pipes conforming to IS 1239:1990 with latest amendments, including fixing Collars, Elbows, Tees, bends, Glad Cocks and other Fittings (Excluding Cost of Specials) with Cuts and Threads wherever necessary including conveying the materials to workspot, including testing for water tightness with all lead and lifts etc completeMtr241.5241.51282.0FalseNoneNoneFalseNoneFalse309603.00
278305588837NoneKKRDBARDOHT07Providing wrought mild steel (galvanized) 15 mm dia GI collar confirming to IS 1239-II, 1991 with latest amendments if any.No61.9561.95320.0FalseNoneNoneFalseNoneFalse19824.00
278305688837NoneKKRDBARDOHT08Providing wrought mild steel (galvanized) 15 mm dia GI Bend confirming to IS 1239-II, 1991 with latest amendments if any.No103.95103.95640.0FalseNoneNoneFalseNoneFalse66528.00
278305788837NoneKKRDBARDOHT09Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendmentsNo16390.516390.530.0FalseNoneNoneFalseNoneFalse491715.00
278305888837NoneKKRDBARDOHT10Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1x3x1.5 SqmNo68.2568.251200.0FalseNoneNoneFalseNoneFalse81900.00
278305988837NoneKKRDBARDOHT11Providing and fixing in position brass Bib cock of approved quality 15mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications.Each300.3300.3350.0FalseNoneNoneFalseNoneFalse105105.00
278306088837NoneKKRDBARDOHT12Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) upto 50 MtrMtr370.0370.0600.0FalseNoneNoneFalseNoneFalse222000.00
278306188837NoneKKRDBARDOHT13B) 51 to 100.00 mtrsMtr464.0464.0600.0FalseNoneNoneFalseNoneFalse278400.00
278306288837NoneKKRDBARDOHT14c) 101 to 150.00 mtrsMtr493.0493.0600.0FalseNoneNoneFalseNoneFalse295800.00
278306388837NoneKKRDBARDOHT15c) 151 to200.00 mtrsMtr572.0572.0120.0FalseNoneNoneFalseNoneFalse68640.00
278306488837NoneKKRDBARDOHT16Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty.Mtr1933.01933.0168.0FalseNoneNoneFalseNoneFalse324744.00
278306588837NoneKKRDBARDOHT17Providing and laying at site of work MS casing caps as per IS 1239 (part- II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in chargeEach164.0164.012.0FalseNoneNoneFalseNoneFalse1968.00
278306688837NoneKKRDBARDOHT18Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendmentsEach150.0150.072.0FalseNoneNoneFalseNoneFalse10800.00
278306788837NoneKKRDBARDOHT19Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 10 HP 2.00 HP/1.5KW, 10 STGNo16993.016993.018.0FalseNoneNoneFalseNoneFalse305874.00
278306888837NoneKKRDBARDOHT20Supplying HDPE pipes PE100PN 6.0 / 6 Kg/cm2 conforming to IS 4984:1995 with latest amendments and conveying to work site including loading and unloading at both destination and rolling, lowering into trenches, laying true to line and jointing of pipes and specials by electrofusion welding, as per standerd procedure and guide lines including encasing the pipe around to a depth not less than 15cms with cleaned soft gravel or selected earth available from the excavation etc., complete giving hydraulic test as per relevant IS Specification with all lead and lift including , testing and commissioning. The rate is exclusive of required specials and fittings etc., complete (Contractor will make his own arrangement for procuring water for testing)Upto 110mm dia,Coils shall be used. Note:Up to 110 mm dia Coil shall be used. For HDPE Grade PE80-PN8.0,63mm diaMtr198.45198.452750.0FalseNoneNoneFalseNoneFalse545737.50
278306988837NoneKKRDBARDOHT21Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1x3x 6 Sq.mMtr194.25194.252750.0FalseNoneNoneFalseNoneFalse534187.50
278307088837NoneKKRDBARDOHT22Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor typeNo6825.06825.018.0FalseNoneNoneFalseNoneFalse122850.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17086787050000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17086787050000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17086787050000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17086787190000NoneNoneELIGIBILITYFor Details Refer Tender Notifcation And Conditions In The Bid DocumentNone
17086787270000NoneNoneELIGIBILITYAll materials should be in good quality as per specifcation, quality certifcate for the same should be obtained from the concerned authority at their own cost.None
17086787330000NoneNoneELIGIBILITYAcceptence / Cancellation of the works are reserved by under signed without any reasons for the sameNone
17086787390000NoneNoneELIGIBILITYCorrigendums / modifcations / correction, if any, will be published in the website only.None
17086787440000NoneNoneELIGIBILITYAll the scanned documents pertaining to bidder to be uploaded shall be in original and same originals should be produced to the Executive Engineer (at the time of Technical Bid Opening) who reserves right to verify the orginal documents before approvalNone
17086787490000NoneNoneELIGIBILITYTo qualify for award of this contract, each tenderer should give all details and documents as per Technical and Financial bid attached to this tenderNone
17086787550000NoneNoneELIGIBILITYAll the materials to be utilised for the work must be tested in RED/PWD/ENGINEERING COLLEGE and OTHER ASSIGNED LABS of KRDB Decisions and Quality control test reports must be enclosed to the bills. Cost of all QC test must be borne by contractorNone
17086787610000NoneNoneELIGIBILITYIf any date in the tender time table is government holiday, next working date will be consideredNone
17086787650000NoneNoneELIGIBILITYIncomplete / conditional tenders will not be acceptedNone
17086787710000NoneNoneELIGIBILITYTenderer must submit his present accurate postal address and phone / cell phone numberNone
17086787750000NoneNoneELIGIBILITYThe tender may be cancelled at any stage without assigning any reasonNone
17086787820000NoneNoneELIGIBILITYThe rates of items are inclusive of cost of materials, labour charges, HOM of machinery, all lead and lifts and all other charges to complete the work successfully as per specifcations and as directed by engineer in charge of workNone
17086787900000NoneNoneELIGIBILITYThe tenderers must submit the scanned documents in pdf / jpeg form, not in other form.None
17086787980000NoneNoneELIGIBILITYAny objection regarding the tender must be submitted directly to Executive Engineer , not in inward.None
17086788070000NoneNoneELIGIBILITYFor interpretations of clauses, conditions, spelling mistakes, etc. decision of Executive Engineer, RDW&S, Bidar is fnalNone
17086788430000NoneNoneELIGIBILITYThe bidder must submit last 5 years Proft and loss account obtained from Chartered Accountant (CA) Only. Bidder must have annual contractaverage turn over for 1 year not less than amount put to tender. the bidder must have minimum assessed available tender capacity amount put to tender as per formula in KW document provided here withNone
17086788510000NoneNoneELIGIBILITYUnconditional Liquid Assets/Bank Line of Credit from any Nationalized/ Scheduled bank of not less than 30% of amount put to tenderNone
17086788570000NoneNoneELIGIBILITYGST Shall paid seperatelyNone
17086788770000NoneNoneELIGIBILITYSatisfactory Completion as a Prime Contractor for Atleast any Construction Work to an Extent of 25% of the Cost of the WorkNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneSatisfactory Completion as a Prime Contractor for Atleast any Construction Work to an Extent of 25% of the Cost of the WorkPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneValid PWD/CPWD Contractor Registration certifcateCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneThe bidder must submit last 5 years Proft and loss account obtained from Chartered Accountant (CA) Only. Bidder must have annual contractaverage turn over for 1 year not less than amount put to tender. the bidder must have minimum assessed available tender capacity amount put to tender as per formula in KW document provided here withFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneUnconditional Liquid Assets/Bank Line of Credit from any Nationalized/ Scheduled bank of not less than 30% of amount put to tenderFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneAnnual Turnover certifcate by CA for 5 years (must be included UDIN no) for 2018-19 to 2022-23Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneList of works for which tenders already submittedOthersFORMAT
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- FORMAT
NoneNoneNoneNoneList of existing commitments and ongoing worksOthersformat
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- FORMAT
NoneNoneNoneNoneBanker Details for referenceOthersformat
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- FORMAT
NoneNoneNoneNoneGST AND PAN CARD CERTIFICATEOthersGST AND PAN CARD CERTIFICATE
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
NoneNoneNoneNoneMUST BE UPLOAD ALL DOCUMENTS AS PER KW STANDERDS BID DOCUMENTOthersALL TECHNICAL BID DOCUMENTS
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- KW DOCUMENTS
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover Certificate Should be UDIN noTrueTechnical Bid
Valid PWD/CPWD Registration CertificateTrueTechnical Bid
ST Reserved Category CertificateTrueTechnical Bid
PAN CARD AND GST CERTIFICATETrueTechnical Bid
Satisfactory Completion as a Prime Contractor for Atleast any Construction Work to an Extent of 25PERCENT of the Cost of the WorkTrueTechnical Bid
Other relevant Documents As per Tender BookletTrueTechnical Bid
Unconditional Liquid Assets/Bank Line of Credit from any Nationalized/ Scheduled bank of not less than 30Percent of amount put to tenderTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone