createdTs None version None createdDate None modifiedDate None noticeInvitingTenderDTO
createdTs 1708678703921 version 3 createdDate None modifiedDate None tenderType RFQ evaluationType TWO_COVER evaluationTypeText Two Cover invitingStrategy RESERVED invitingStrategyText Reserved taxType INCLUSIVE_TAX tenderFee 2050.00 emd 82000.00 bidValueType ITEM_WISE bidValueTypeText Item wise tenderReceiptClose 02-03-2024 17:00:00 tenderQueryClose 29-02-2024 17:00:00 technicalBidOpen 04-03-2024 11:00:00 publishedDate 23-02-2024 16:20:47 publishedByPost RWSSD_EE_DIV_BID publishedByUser KPE12515 - RAMALINGAPPA BIRADAR bidValidityPeriod 90 noOfCalls 1 preBidMeetingDate None preBidMeetingYn False preQualificationBidOpen None denominationType RUPEES denominationTypeText Rupees retenderedYn None percentageRateTypeText None contactPerson Pradeep Patil splitEmdRequiredYn False emdBankGuarantee None emdCash None bgValidityPeriod None hideWeightage None multipleCurrencySelectionAllowedYn False isTechWeightageAllowed False highestBidderSelection False isVariableEmdAllowed None qcbsTenderYn None itemwiseEmdRequiredYn None sampleSubmissionDate None officeNumber None mobileNumber 9538567662 tenderSupplierList None tenderSchedule
createdTs 1708678703965 version 4 createdDate None modifiedDate None tenderNumber RWSSD/2023-24/WS/WORK_INDENT7861 title Construction of Water Overhead Tank in Govt HPS RMSA Koundgaon and Other 49 Govt. Schools in Aurad (B) Taluka (AKSHARA AVISHKARA Work Code -BDR231231194 ,BDR231232195 &BDR231233196) Belongs to ST Category description Construction of Water Overhead Tank in Aurad tq.at 1)Govt HPS and RMSA Koundgaon 2)Govt HPS and RMSA Hangarga 3)Govt HPS Handikera4)Govt HS Aurad B5)Govt HS Hokrana6)Govt HS Murki7)Govt HPS Santhpur8)Govt HS Ekamba9)Govt HS Torna10)Govt HS Chavar dabka11)Govt HS Kushnoor12)Govt HS Mudhol B13)Govt HS Dhupatmahagaon14)Govt HS Jambgi15)Govt HS Chintaki16)Govt HS Nagmarpalli17)Govt HS Eklar18)Govt HS Yengunda19)Govt HS Holsamudra20)Govt HPS Teacher colony Aurad21)Govt HPS Jambagi22)karnataka Public school Govt MPS Kushnoor23)Govt MPS Murki24)Govt HPS Hokrana25)Govt MPS Chavar Dabka26)Govt HPS Chintaki27)Govt MPS Wadgaon D28)Govt HPS Belkuni B29)Govt HPS Bhandarkumta30)Govt MPS Kamalnagar31)Govt HPS Yengunda32)Govt HPS Kherda B33)Govt MPS Santhpur34)Govt HPS Dhupatmahagaon35)Govt HPS chikli U36)Govt HPS Belkuni ch37)Govt HPS Wanmarpalli38)GHPS Urdu kamalnagar39)Govt HPS Bawalgaon40)Govt HPS Ganganbeed41)Govt HPS Badalgaon42)Govt HPS Chikli J43)Govt HPS Ashoknagar thanda Chintaki44)Govt HPS Kollur45)Govt HPS Sundal46)Govt HPS Holsamudra47)Govt HPS Nandi Bijalgaon48)Govt HPS Bonthi49)Govt HPS Gudpalli50)Govt LPS Hulyal (AKSHARA AVISHKARA Work Code -BDR231231194 ,BDR231232195 &BDR231233196) Belongs to ST Category category WORKS categoryText Works ecv 8194654.64 deptName Rural Drinking Water and Sanitation Department status PUBLISHED statusText Published remarks None csrValue None ecvtenderYn True location 1106 locationName RWSSD Division Office Bidar provisionalAmount 9990000.0 groupOverheadTotal None fileNumber BDR231231194andBDR231232195andBDR231233196 tenderSubEstimateList
createdTs version createdDate modifiedDate workCategoryName subEstimateName estimateTotal itemList 1708678704000 0 None None Water supply/sewage lines Construction of Water Overhead Tank in Govt HPS RMSA Koundgaon and Other 49 Govt. Schools in Aurad (B) Taluka (AKSHARA AVISHKARA Work Code -BDR231231194 ,BDR231232195 &BDR231233196) 8194654.64
id tenderSubEstimateId categoryName itemCode description uomName baseRate finalRate quantity modifyQuantityYn minQuantity maxQuantity buyBackYn buyBackValue hideYn netAmount taxCount 2783049 88837 None KKRDBARDOHT01 Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50m Cum 508.2 508.2 1452.12 False None None False None False 737967.384 0 2783050 88837 None KKRDBARDOHT02 Providing and fixing Chlorinated Polyvinyle Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings. Including fixing the pipe with clamps at 1m spacing this includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints as per direction of Engineer incharge-External work.Internal work-Exposed on Wall Mtr 390.6 390.6 7171.0 False None None False None False 2800992.6 0 2783051 88837 None KKRDBARDOHT03 Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications Cum 168.0 168.0 1452.12 False None None False None False 243956.16 0 2783052 88837 None KKRDBARDOHT04 Supplying of Gate value 32mm nominal bore-gun metal. No 614.25 614.25 250.0 False None None False None False 153562.5 0 2783053 88837 None KKRDBARDOHT05 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.1000 Ltr Ltr 9.45 9.45 50000.0 False None None False None False 472500.0 0 2783054 88837 None KKRDBARDOHT06 Supplying,laying,jointing ,testing and commissioning of G.I. Pipes conforming to IS 1239:1990 with latest amendments, including fixing Collars, Elbows, Tees, bends, Glad Cocks and other Fittings (Excluding Cost of Specials) with Cuts and Threads wherever necessary including conveying the materials to workspot, including testing for water tightness with all lead and lifts etc complete Mtr 241.5 241.5 1282.0 False None None False None False 309603.0 0 2783055 88837 None KKRDBARDOHT07 Providing wrought mild steel (galvanized) 15 mm dia GI collar confirming to IS 1239-II, 1991 with latest amendments if any. No 61.95 61.95 320.0 False None None False None False 19824.0 0 2783056 88837 None KKRDBARDOHT08 Providing wrought mild steel (galvanized) 15 mm dia GI Bend confirming to IS 1239-II, 1991 with latest amendments if any. No 103.95 103.95 640.0 False None None False None False 66528.0 0 2783057 88837 None KKRDBARDOHT09 Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments No 16390.5 16390.5 30.0 False None None False None False 491715.0 0 2783058 88837 None KKRDBARDOHT10 Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1x3x1.5 Sqm No 68.25 68.25 1200.0 False None None False None False 81900.0 0 2783059 88837 None KKRDBARDOHT11 Providing and fixing in position brass Bib cock of approved quality 15mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. Each 300.3 300.3 350.0 False None None False None False 105105.0 0 2783060 88837 None KKRDBARDOHT12 Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) upto 50 Mtr Mtr 370.0 370.0 600.0 False None None False None False 222000.0 0 2783061 88837 None KKRDBARDOHT13 B) 51 to 100.00 mtrs Mtr 464.0 464.0 600.0 False None None False None False 278400.0 0 2783062 88837 None KKRDBARDOHT14 c) 101 to 150.00 mtrs Mtr 493.0 493.0 600.0 False None None False None False 295800.0 0 2783063 88837 None KKRDBARDOHT15 c) 151 to200.00 mtrs Mtr 572.0 572.0 120.0 False None None False None False 68640.0 0 2783064 88837 None KKRDBARDOHT16 Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. Mtr 1933.0 1933.0 168.0 False None None False None False 324744.0 0 2783065 88837 None KKRDBARDOHT17 Providing and laying at site of work MS casing caps as per IS 1239 (part- II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge Each 164.0 164.0 12.0 False None None False None False 1968.0 0 2783066 88837 None KKRDBARDOHT18 Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments Each 150.0 150.0 72.0 False None None False None False 10800.0 0 2783067 88837 None KKRDBARDOHT19 Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 10 HP 2.00 HP/1.5KW, 10 STG No 16993.0 16993.0 18.0 False None None False None False 305874.0 0 2783068 88837 None KKRDBARDOHT20 Supplying HDPE pipes PE100PN 6.0 / 6 Kg/cm2 conforming to IS 4984:1995 with latest amendments and conveying to work site including loading and unloading at both destination and rolling, lowering into trenches, laying true to line and jointing of pipes and specials by electrofusion welding, as per standerd procedure and guide lines including encasing the pipe around to a depth not less than 15cms with cleaned soft gravel or selected earth available from the excavation etc., complete giving hydraulic test as per relevant IS Specification with all lead and lift including , testing and commissioning. The rate is exclusive of required specials and fittings etc., complete (Contractor will make his own arrangement for procuring water for testing)Upto 110mm dia,Coils shall be used. Note:Up to 110 mm dia Coil shall be used. For HDPE Grade PE80-PN8.0,63mm dia Mtr 198.45 198.45 2750.0 False None None False None False 545737.5 0 2783069 88837 None KKRDBARDOHT21 Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1x3x 6 Sq.m Mtr 194.25 194.25 2750.0 False None None False None False 534187.5 0 2783070 88837 None KKRDBARDOHT22 Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type No 6825.0 6825.0 18.0 False None None False None False 122850.0 0 generalCriterionList
createdTs version createdDate modifiedDate criterionType description tenderEligibilityCriterionDocumentList 1708678705000 0 None None ELIGIBILITY Tenders from Joint ventures are not acceptable. None 1708678705000 0 None None ELIGIBILITY Bidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None 1708678705000 0 None None ELIGIBILITY Bidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document. None 1708678719000 0 None None ELIGIBILITY For Details Refer Tender Notifcation And Conditions In The Bid Document None 1708678727000 0 None None ELIGIBILITY All materials should be in good quality as per specifcation, quality certifcate for the same should be obtained from the concerned authority at their own cost. None 1708678733000 0 None None ELIGIBILITY Acceptence / Cancellation of the works are reserved by under signed without any reasons for the same None 1708678739000 0 None None ELIGIBILITY Corrigendums / modifcations / correction, if any, will be published in the website only. None 1708678744000 0 None None ELIGIBILITY All the scanned documents pertaining to bidder to be uploaded shall be in original and same originals should be produced to the Executive Engineer (at the time of Technical Bid Opening) who reserves right to verify the orginal documents before approval None 1708678749000 0 None None ELIGIBILITY To qualify for award of this contract, each tenderer should give all details and documents as per Technical and Financial bid attached to this tender None 1708678755000 0 None None ELIGIBILITY All the materials to be utilised for the work must be tested in RED/PWD/ENGINEERING COLLEGE and OTHER ASSIGNED LABS of KRDB Decisions and Quality control test reports must be enclosed to the bills. Cost of all QC test must be borne by contractor None 1708678761000 0 None None ELIGIBILITY If any date in the tender time table is government holiday, next working date will be considered None 1708678765000 0 None None ELIGIBILITY Incomplete / conditional tenders will not be accepted None 1708678771000 0 None None ELIGIBILITY Tenderer must submit his present accurate postal address and phone / cell phone number None 1708678775000 0 None None ELIGIBILITY The tender may be cancelled at any stage without assigning any reason None 1708678782000 0 None None ELIGIBILITY The rates of items are inclusive of cost of materials, labour charges, HOM of machinery, all lead and lifts and all other charges to complete the work successfully as per specifcations and as directed by engineer in charge of work None 1708678790000 0 None None ELIGIBILITY The tenderers must submit the scanned documents in pdf / jpeg form, not in other form. None 1708678798000 0 None None ELIGIBILITY Any objection regarding the tender must be submitted directly to Executive Engineer , not in inward. None 1708678807000 0 None None ELIGIBILITY For interpretations of clauses, conditions, spelling mistakes, etc. decision of Executive Engineer, RDW&S, Bidar is fnal None 1708678843000 0 None None ELIGIBILITY The bidder must submit last 5 years Proft and loss account obtained from Chartered Accountant (CA) Only. Bidder must have annual contractaverage turn over for 1 year not less than amount put to tender. the bidder must have minimum assessed available tender capacity amount put to tender as per formula in KW document provided here with None 1708678851000 0 None None ELIGIBILITY Unconditional Liquid Assets/Bank Line of Credit from any Nationalized/ Scheduled bank of not less than 30% of amount put to tender None 1708678857000 0 None None ELIGIBILITY GST Shall paid seperately None 1708678877000 0 None None ELIGIBILITY Satisfactory Completion as a Prime Contractor for Atleast any Construction Work to an Extent of 25% of the Cost of the Work None preQualCriterionList None technicalCriterionList
createdTs version createdDate modifiedDate description criterionCategoryText criterionTypeOthersValue tenderTechnicalCriterionDocumentList None None None None Satisfactory Completion as a Prime Contractor for Atleast any Construction Work to an Extent of 25% of the Cost of the Work Past Experience None
createdTs version createdDate modifiedDate documentName None None None None Work Done Certificate None None None None Valid PWD/CPWD Contractor Registration certifcate Capabilities of Vendor None
createdTs version createdDate modifiedDate documentName None None None None PWD Registration Certificate (Class I/II/III/IV) None None None None The bidder must submit last 5 years Proft and loss account obtained from Chartered Accountant (CA) Only. Bidder must have annual contractaverage turn over for 1 year not less than amount put to tender. the bidder must have minimum assessed available tender capacity amount put to tender as per formula in KW document provided here with Financial Status None
createdTs version createdDate modifiedDate documentName None None None None Audited CA Certificate of Annual Turnover None None None None Unconditional Liquid Assets/Bank Line of Credit from any Nationalized/ Scheduled bank of not less than 30% of amount put to tender Financial Status None
createdTs version createdDate modifiedDate documentName None None None None Line of Credit None None None None Annual Turnover certifcate by CA for 5 years (must be included UDIN no) for 2018-19 to 2022-23 Financial Status None
createdTs version createdDate modifiedDate documentName None None None None Audited CA Certificate of Annual Turnover None None None None List of works for which tenders already submitted Others FORMAT
createdTs version createdDate modifiedDate documentName None None None None Others -- FORMAT None None None None List of existing commitments and ongoing works Others format
createdTs version createdDate modifiedDate documentName None None None None Others -- FORMAT None None None None Banker Details for reference Others format
createdTs version createdDate modifiedDate documentName None None None None Others -- FORMAT None None None None GST AND PAN CARD CERTIFICATE Others GST AND PAN CARD CERTIFICATE
createdTs version createdDate modifiedDate documentName None None None None GST Registration None None None None MUST BE UPLOAD ALL DOCUMENTS AS PER KW STANDERDS BID DOCUMENT Others ALL TECHNICAL BID DOCUMENTS
createdTs version createdDate modifiedDate documentName None None None None Others -- KW DOCUMENTS tenderCriterionDocumentList
documentName optional documentTypeText Annual Turnover Certificate Should be UDIN no True Technical Bid Valid PWD/CPWD Registration Certificate True Technical Bid ST Reserved Category Certificate True Technical Bid PAN CARD AND GST CERTIFICATE True Technical Bid Satisfactory Completion as a Prime Contractor for Atleast any Construction Work to an Extent of 25PERCENT of the Cost of the Work True Technical Bid Other relevant Documents As per Tender Booklet True Technical Bid Unconditional Liquid Assets/Bank Line of Credit from any Nationalized/ Scheduled bank of not less than 30Percent of amount put to tender True Technical Bid tenderWorkLocationList tenderAddress None tenderRecallDTO None