tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1708614891000 | 0 | None | None | Buildings | Construction of Govt.HPS , 2- Rooms in Hegginal Village in Jewargi Taluka, Dist.Kalaburagi. Under-KKRDB Micro General Grant for 2023-24.(KLB231023360) | 2698154.37 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2770318 | 88308 | None | v-3 CSR-2021-22 It. No.2.5(ii) (b) Pg. no.9 | Clearing and grubbing road land including
uprooting rank vegetation, grass, bushes,
shrubs, saplings and trees girth up to 300
mm, removal of stumps of trees cut earlier
and disposal of unserviceable materials
and stacking of serviceable material to be
used or auctioned, including removal and
disposal of top organic soil not exceeding
150 mm in thickness-By Mechanical
Means using Dozer-In area of thorny
jungle | 100 Sqm | 508.2 | 508.2 | 3.0 | False | None | None | False | None | False | 1524.6 | 0 | 2770319 | 88308 | None | V-1 It. No.1.19.1 Page No. 10 | Earth work excavation for pipeline trenches by mechanical means as per
drawing and technical specifications, including setting out, construction
of shoring, strutting, barricading, caution lights, bracing, using sight rails
& bonding rods at every 100 mm wherever necessary as directed, removal
of stumps and other deleterious matter, dressing of sides and levelling the
bottom of trench to the extent required , utilising the available excavated earth
locally for the work and all other appurtenances to complete in the following
strata. Ordinary/soft rock (without requiring blasting) Depth upto 1.50 m | Cum | 476.7 | 476.7 | 115.1 | False | None | None | False | None | False | 54868.17 | 0 | 2770320 | 88308 | None | V-1 CSR It. No. 2.1.2 Pg. no.15 | Providing and laying in Position plain
cement concrete for levelling course for all
works in foundation. The
granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per
relevent IS codes machine mixed, laid in
layers not exceeding 150mm thickness,
well compacted using plate vibrator,
including all lead & lifts, cost of all
materials of quality, labour, usage charges
of machineries, curing, and all the other
appurtences required to complete the
work as per technical specifications. ( The
cost of steel reinforcement & formwork
shall be paid separately)-Mix 1:4:8 (M7.5)
using 40mm nominal size graded
crushed coarse aggregates. | Cum | 5947.2 | 5947.2 | 11.77 | False | None | None | False | None | False | 69998.544 | 0 | 2770321 | 88308 | None | CSR It. No. 5.1.1 Pg. no.9 | Providing Random rubble masonary with
hard stone in foundation and plinth
including levelling up with cement
concrete 1:6: (1cement:6course sand:)
upto Plinth level etc. complete. | Cum | 5891.55 | 5891.55 | 28.95 | False | None | None | False | None | False | 170560.3725 | 0 | 2770322 | 88308 | None | CSR It. No. 5.4 Pg. no.9 | Providing Size Stone masonary with hard
stone in foundation and plinth including
levelling up with cement concrete 1:6:
(1cement:6course sand:) upto Plinth level
etc. complete. | Cum | 6708.45 | 6708.45 | 18.2 | False | None | None | False | None | False | 122093.79 | 0 | 2770323 | 88308 | None | CSR It. No. 1.9 Page No. 7 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of
foundations and other similar works etc. in layers not exceeding 20cm in depth,
consolidating each deposited layer by ramming and watering, lead up to 50 m
and lift upto 1.5 m. | Cum | 279.3 | 279.3 | 144.96 | False | None | None | False | None | False | 40487.328 | 0 | 2770324 | 88308 | None | Vol-I I no. 2.2.1 Page No. 15 | Providing and laying in position Cement Concrete for all Foundation works.
The granite/trap/basalt crushed graded coarse aggregates and fine aggregates
as per relevant IS Codes machine mixed with super plasticizers laid in finished
layers, well compacted using needle vibrators, including all lead & lifts, cost
of all materials, quality confirming to the requirements of relevant IS codes,
labour, Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6601.35 | 6601.35 | 14.85 | False | None | None | False | None | False | 98030.0475 | 0 | 2770325 | 88308 | None | Vol-I S R Sl No. 1 a Page No. 111 | Addendum I-Percentage Additionalities for Formwork,
Centering & Scaffolding Foundation upto Plinth a. Isolated add 8% | Cum | 528.11 | 528.11 | 14.85 | False | None | None | False | None | False | 7842.4335 | 0 | 2770326 | 88308 | None | Vol-1 CSR It. No. 2.2.1 Pg. no. 15 | Providing and laying in position Cement Concrete for all Foundation works.
The granite/trap/basalt crushed graded coarse aggregates and fine aggregates
as per relevant IS Codes machine mixed with super plasticizers laid in finished
layers, well compacted using needle vibrators, including all lead & lifts, cost
of all materials, quality confirming to the requirements of relevant IS codes,
labour, Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6601.35 | 6601.35 | 6.77 | False | None | None | False | None | False | 44691.1395 | 0 | 2770327 | 88308 | None | Vol-I S R Sl No. 9 Page no. 111 | Addendum I-Percentage Additionalities for Formwork,
Centering & Scaffolding for RCC Columns / Shaft (Slip Centering) add 70 Percent | Cum | 4620.94 | 4620.94 | 6.77 | False | None | None | False | None | False | 31283.7638 | 0 | 2770328 | 88308 | None | Vol-1 I No. 2.2.1 Page No. 15 | Providing and laying in position Cement Concrete for all Foundation works.
The granite/trap/basalt crushed graded coarse aggregates and fine aggregates
as per relevant IS Codes machine mixed with super plasticizers laid in finished
layers, well compacted using needle vibrators, including all lead & lifts, cost
of all materials, quality confirming to the requirements of relevant IS codes,
labour, Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6601.35 | 6601.35 | 0.48 | False | None | None | False | None | False | 3168.648 | 0 | 2770329 | 88308 | None | Vol-I S R Sl no. 19 Page No. 112 | Addendum I-Percentage Additionalities for Formwork,
Centering & Scaffolding for Chejjas, Canopy & Other Architectural projections of
minor sections) add 45 Percent | Cum | 2970.61 | 2970.61 | 0.48 | False | None | None | False | None | False | 1425.8928 | 0 | 2770330 | 88308 | None | Vol-1 I No. 2.2.1 Page No. 15 | Providing and laying in position Cement Concrete for all Foundation works.
The granite/trap/basalt crushed graded coarse aggregates and fine aggregates
as per relevant IS Codes machine mixed with super plasticizers laid in finished
layers, well compacted using needle vibrators, including all lead & lifts, cost
of all materials, quality confirming to the requirements of relevant IS codes,
labour, Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6601.35 | 6601.35 | 5.18 | False | None | None | False | None | False | 34194.993 | 0 | 2770331 | 88308 | None | Vol-I S R Sl No. 2 Page No. 111 | Addendum I-Percentage Additionalities for Formwork,
Centering & Scaffolding for Plinth Beams of Building add 50% | Cum | 3300.67 | 3300.67 | 5.18 | False | None | None | False | None | False | 17097.4706 | 0 | 2770332 | 88308 | None | Vol-1 CSR It. No. 2.2.1 Pg. no. 15 | Providing and laying in position Cement Concrete for all Foundation works.
The granite/trap/basalt crushed graded coarse aggregates and fine aggregates
as per relevant IS Codes machine mixed with super plasticizers laid in finished
layers, well compacted using needle vibrators, including all lead & lifts, cost
of all materials, quality confirming to the requirements of relevant IS codes,
labour, Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6601.35 | 6601.35 | 10.43 | False | None | None | False | None | False | 68852.0805 | 0 | 2770333 | 88308 | None | Vol-I S R Sl No. 14 Page No. 111 | Addendum I-Percentage Additionalities for Formwork,
Centering & Scaffolding for RCC Beams, Lintels & Troughs of Aqueducts add 60% | Cum | 3960.81 | 3960.81 | 10.43 | False | None | None | False | None | False | 41311.2483 | 0 | 2770334 | 88308 | None | Vol-1 CSR It. No. 2.2.1 Pg. no. 15 | Providing and laying in position Cement Concrete for all Foundation works.
The granite/trap/basalt crushed graded coarse aggregates and fine aggregates
as per relevant IS Codes machine mixed with super plasticizers laid in finished
layers, well compacted using needle vibrators, including all lead & lifts, cost
of all materials, quality confirming to the requirements of relevant IS codes,
labour, Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6601.35 | 6601.35 | 18.28 | False | None | None | False | None | False | 120672.678 | 0 | 2770335 | 88308 | None | Vol-I S R Sl no. 15 Page No. 112 | Addendum I-Percentage Additionalities for Formwork,
Centering & Scaffolding for RCC Roof Slabs add 50% | Cum | 3300.67 | 3300.67 | 18.28 | False | None | None | False | None | False | 60336.2476 | 0 | 2770336 | 88308 | None | Vol-I I No. 2.11 a Page No. 18 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement
including cost of all materials, machinery, labour, cleaning, straightening,
cutting, bending, hooking, laping/welding joints, tying with binding wire / soft
annealed steel wire and other ancilary operations complete as per drawing and
technical specification. Buildings | t | 93929.85 | 93929.85 | 4.87 | False | None | None | False | None | False | 457438.3695 | 0 | 2770337 | 88308 | None | Vol-II I No. 6.7 Page No. 13 | Providing Brick work with common burnt clay Non Modular bricks of
class designation 3.5 in superstructure above plinth level in all shapes and
sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of
all materials, labour, scaffolding and usage charges of machinery & other
incidental charges complete as per the direction of engineer incharge of
work. | Cum | 8621.55 | 8621.55 | 34.1 | False | None | None | False | None | False | 293994.855 | 0 | 2770338 | 88308 | None | Vol-II I No. 12.11 Page No. 99 | Providing Honne wood frames of doors, windows, clerestory windows,
ventilators and other frames, wrought, framed or assembled including
making plaster groves (excluding cost of cement concrete and side clamps),
but including cost of materials, labour, usage charges complete as per
specifications. | Cum | 144977.7 | 144977.7 | 0.83 | False | None | None | False | None | False | 120331.491 | 0 | 2770339 | 88308 | None | Vol-II I No. 12.51 Page No. 104 | Fixing of door frame in an existing opening including embedding frame in
floor and walls after cutting masonry for holdfasts for embedding holdfast
in cement concrete 1:3:6 of 20mm and down size granite metal painting
two coats of coal tar to sides of frame, making good the damages to walls
and floor as required and disposal of the debris with lead upto 50 m.
including cost of materials, labour charges, complete as per specifications. | No | 1066.8 | 1066.8 | 4.0 | False | None | None | False | None | False | 4267.2 | 0 | 2770340 | 88308 | None | Vol-II I No. 12.52 Page No. 104 | Fixing of window frame in an existing opening including embedding frame
in floor and walls after cutting masonry for holdfasts for embedding
holdfast in cement concrete 1:3:6 of 20mm and down size granite metal
painting two coats of coal tar to sides of frame, making good the damages
to walls and floor as required and disposal of the debries with lead
upto 50 m. including cost of materials, labour charges, complete as per
specifications. | No | 811.65 | 811.65 | 6.0 | False | None | None | False | None | False | 4869.9 | 0 | 2770341 | 88308 | None | Vol-II I No. 12.23 Page no. 101 | Providing and fixing in position Honnewood fully panelled shutters for
windows with stiles and rails of 35mm. thick, 75mm wide in two
halves with panels of 25mm thick including cost of materials, labour
charges, usage charges complete as per specifications. (excluding cost of
fixtures) | Sqm | 7952.7 | 7952.7 | 10.08 | False | None | None | False | None | False | 80163.216 | 0 | 2770342 | 88308 | None | Vol-II I No. 12.31 Page No. 101 | Providing and fixing in position Honne wood fully panelled shutters for
windows with stiles and rails of 25mm. thick, 75mm wide in two
halves with panels of 20mm thick including cost of materials, labour
charges, usage charges complete as per specifications. (excluding cost of
fixtures) | Sqm | 6576.15 | 6576.15 | 10.8 | False | None | None | False | None | False | 71022.42 | 0 | 2770343 | 88308 | None | Vol-II I No. 11.34 A Page No. 86 | Providing and fixing M.S. grills of required pattern in frames of windows
etc. with M.S. flats, square or round bars etc. including priming coat with
approved steel primer all complete. Fixed to steel windows by welding | Kg | 176.4 | 176.4 | 383.04 | False | None | None | False | None | False | 67568.256 | 0 | 2770344 | 88308 | None | Vol-II I No. 8.5.2 Page No. 42 | Providing 15 mm cement plaster on rough side of single or half brick
wall finished with a floating coat of neat cement of mix: 1:4 (1 cement:
4 fine sand) to brick masonry including rounding off corners wherever
required smooth rendering, providing and removing scaffolding, including
cost of materials, labour, curing complete as per specifications and as per
directions of Engineer-in-charge | Sqm | 366.45 | 366.45 | 155.66 | False | None | None | False | None | False | 57041.607 | 0 | 2770345 | 88308 | None | Vol-II I No. 8.4.1 Page no. 41 | Providing 12 mm cement plaster finished with a floating coat of neat
cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including
rounding off corners wherever required smooth rendering, providing and
removing scaffolding, including cost of materials, labour, curing complete
as per specifications and as per directions of Engineer-in-charge. | Sqm | 423.94 | 423.94 | 111.57 | False | None | None | False | None | False | 47298.9858 | 0 | 2770346 | 88308 | None | Vol-II I No. 8.8 Page No. 42 | Providing 18 mm cement plaster in two coats under layer 12 mm thick
cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished
with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1
cement : 6 fine sand) to brick masonry including rounding off corners
wherever required smooth rendering, providing and removing scaffolding,
including cost of materials, labour, curing complete as per specifications
and as per directions of Engineer-in-charge. | Sqm | 482.3 | 482.3 | 198.46 | False | None | None | False | None | False | 95717.258 | 0 | 2770347 | 88308 | None | Vol-I I No. 2.1.4 Page No. 15 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in
layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of
machinery, curing, and all the other appurtenances required to complete the
work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6527.85 | 6527.85 | 18.4 | False | None | None | False | None | False | 120112.44 | 0 | 2770348 | 88308 | None | Vol-II I No. 9.19 page No. 61 | Providing and laying Vitrified tiles with thickness 9-10 mm in different
sizes with water absorption less than 0.08% and conforming to IS: 15622,
of approved brand & manufacturer, in all colours and shade, in skirting,
riser, treads of steps, laid with cement based high polymer modified
quick set tile adhesive (water based) conforming to IS: 15477, in average
6 mm thickness, including grouting of joints as per direction of Engineer
in charge. | Sqm | 1231.65 | 1231.65 | 129.19 | False | None | None | False | None | False | 159116.8635 | 0 | 2770349 | 88308 | None | Vol-II I No. 9.6.4 Page no. 59 | Providing and laying Chequerred precast cement concrete tiles 22 mm
thick in footpath & courtyard, jointed with neat cement slurry mixed with
pigment to match the shade of tiles, including rubbing and cleaning etc.
complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse
sand) Ordinary cement without any pigment | Sqm | 1102.5 | 1102.5 | 7.44 | False | None | None | False | None | False | 8202.6 | 0 | 2770350 | 88308 | None | Vol-II I No. 8.32 Page No. 46 | Finishing walls with 100% Premium acrylic emulsion paint having VOC
less than 50 g/L and UV resistance as per IS 15489:2004, Alkali
& fungal resistance, dirt resistance exterior paint of required shade
(Company Depot Tinted) with silicon additives, New work (Two coats
applied @ 1.43 L/ 10 m². Over and including priming coat of exterior
primer applied @ 0.90 L/10 m² with paint of approved quality to give an
even shade, after thoroughly brooming the surface to remove all dirt, dust,
mortar drops and foreign matter including preparing the surface even and
sand paper smooth, cost of materials, labour complete as per specifications
and as per directions of Engineer-in-charge | Sqm | 163.8 | 163.8 | 216.59 | False | None | None | False | None | False | 35477.442 | 0 | 2770351 | 88308 | None | Vol-II I No. 8.28 Page No. 45 | Finishing walls with water proofing cement paint of required shade :New
work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after
thoroughly brooming the surface to remove all dirt, dust, mortar drops
and foreign matter including preparing the surface even and sand paper
smooth, cost of materials, labour complete as per specifications and as per
directions of Engineer-in-charge. | Sqm | 115.7 | 115.7 | 215.14 | False | None | None | False | None | False | 24891.698 | 0 | 2770352 | 88308 | None | Vol-2 I No. 8.51 Page No. 50 | Providing and applying white cement based putty of average thickness
1 mm, of approved brand and manufacturer, over the plastered
wall surface to prepare the surface even and smooth complete as per
specifications and as per directions of Engineer in charge | Sqm | 105.0 | 105.0 | 224.87 | False | None | None | False | None | False | 23611.35 | 0 | 2770353 | 88308 | None | Vol-II I No. 8.33.2 Page No. 46 | Painting wood work with Deluxe Multi Surface Paint of required shade.
Two coat applied @ 0.90L/10 m² over an under coat of primer applied
@0.75 L/10 m² of approved brand and manufacture to give an even shade
including preparing the surface after thorougly cleaning oil, grease, dirt
and foreign matter, sand papering and knotting , cost of materials, labour
complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 144.9 | 144.9 | 54.29 | False | None | None | False | None | False | 7866.621 | 0 | 2770354 | 88308 | None | Vol-II I No. 8.33.3 Page No. 47 | Painting Steel work with Deluxe Multi Surface Paint to give an even
shade. Two coat applied @ 0.90L/10 m² over an under coat of primer
applied @ 0.80 L/10 m² of approved brand and manufacture including
preparing the surface after thorougly cleaning oil, grease, dirt and foreign
matter, cost of materials, labour complete as per specifications and as per
directions of Engineer-in-charge. | Sqm | 145.95 | 145.95 | 32.83 | False | None | None | False | None | False | 4791.5385 | 0 | 2770355 | 88308 | None | Vol-2 CSR It. No. 8.84 Pg. no.55 | Providing wall black boards in 12mm thick
with CM 1:3 and applied with primer & two
coats of acrylic emulsion black paint
including finishing etc.,complete | Sqm | 498.75 | 498.75 | 8.4 | False | None | None | False | None | False | 4189.5 | 0 | 2770356 | 88308 | None | Vol-II I No. 8.19.1 Page No. 44 | Providing Flush/ Ruled pointing: Pointing on stone work with cement
mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as
per directions of Engineer-in-charge. | Sqm | 267.75 | 267.75 | 43.04 | False | None | None | False | None | False | 11523.96 | 0 | 2770357 | 88308 | None | V-3SR 2023-24 It. No. 8.7 Pg. no.65 | Direction and Place Identification Signs
upto 0.9 m2 Size Board :Providing and
erecting direction and place identification
retro-reflectorised sign as per
IRC:67:2012 made of high
intensity grade sheeting vide clause 801.3,
fixed over aluminium sheeting, 2 mm thick
or Aluminium composite
material sheet with overall thickness of
4mm with area not exceeding 0.9 m2 fixed
over back support frame of min 35x 35 x
3mm angle mounted on a mild steel
circular pipe 65 NB, firmly fixed to the
ground by means of properly designed
foundation with M25 grade cement
concrete 45 x 45 x 60 cm, 60 cm below
ground level as per approved drawing | Sqm | 9460.5 | 9460.5 | 1.08 | False | None | None | False | None | False | 10217.34 | 0 |
| 1708614891000 | 0 | None | None | Buildings | ELECTRICAL WORK | 97485.1 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2770358 | 88309 | None | 1.2.2 | Supplying heavy gauge PVC conduit pipe . mm dia.mm thick
confirming to IS 2509 with suitable size bends, metal/PVC Junction
boxes, adhesive paste etc., and running before concreting the slab. The
conduit should be tied to the reinforcement rods by using binding
wires and unused ways of junction boxes and pipe ends should be
covered using PVC end enclosures, run with 18SWG GI fish wire
wherever necessary 25 mm dia 2 mm thick | m | 78.0 | 78.0 | 70.0 | False | None | None | False | None | False | 5460.0 | 0 | 2770359 | 88309 | None | 1.3.2 | Supplying heavy gauge PVC Conduit Pipe . dia . mm thick
with suitable size bends, metal junction boxes adhesive paste etc., by
groove cutting in the wall and fixing by bracing U or J hooks and
cement plastering upto the wall surface and run with 18 SWG GI fish
wire run throughout the conduit wherever necessary.25 mm dia 2 mm thick | m | 79.0 | 79.0 | 40.0 | False | None | None | False | None | False | 3160.0 | 0 | 2770360 | 88309 | None | 1.5.2 | Supplying and fixing PVC/metal conduit Deep junction box 25 mm deep Junction box | Each | 56.0 | 56.0 | 10.0 | False | None | None | False | None | False | 560.0 | 0 | 2770361 | 88309 | None | 1.6.4 | Supplying and flush mounting teak wooden box without front plank,
made of not less than 12 mm thick wood, after due groove cutting,
finishing with necessary cement plastering complete. 8" x 6" x 3" (203 x 152 x 76 mm) | Each | 86.0 | 86.0 | 2.0 | False | None | None | False | None | False | 172.0 | 0 | 2770362 | 88309 | None | 1.6.3 | Supplying and flush mounting teak wooden box without front plank,
made of not less than 12 mm thick wood, after due groove cutting,
finishing with necessary cement plastering complete. 10" x 7" x 3" (254 x 178 x 76 mm) | Each | 112.0 | 112.0 | 2.0 | False | None | None | False | None | False | 224.0 | 0 | 2770363 | 88309 | None | 1.12 | Supplying And Fixing M.S. Rafter Clamp Set made out of M.S.
Flat & 14 mm M.S. rod. | No | 160.0 | 160.0 | 8.0 | False | None | None | False | None | False | 1280.0 | 0 | 2770364 | 88309 | None | page no 5 of item no 2.1.1 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet. GROUP short point up to 3 mtr from tapping point out let via switch | Point | 285.0 | 285.0 | 12.0 | False | None | None | False | None | False | 3420.0 | 0 | 2770365 | 88309 | None | page no 5 item no 2.1.2 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet. GROUP Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch | Point | 394.0 | 394.0 | 6.0 | False | None | None | False | None | False | 2364.0 | 0 | 2770366 | 88309 | None | 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 1.5 mm2 | m | 26.0 | 26.0 | 180.0 | False | None | None | False | None | False | 4680.0 | 0 | 2770367 | 88309 | None | page no 5 item no 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming latest amanment 2.5 sq mm | m | 42.0 | 42.0 | 150.0 | False | None | None | False | None | False | 6300.0 | 0 | 2770368 | 88309 | None | 3.1.1 | Supplying 6A flush type socket and 6 A flush type SP switch either
surface/flush mounting in existing gang box or in 4mm thick plastic
sheet and fixing over a flush mounted wooden box and wiring using
necessary capacity wires as required as per IS 1293 and IS 3854 6A 2 Way | Each | 128.0 | 128.0 | 2.0 | False | None | None | False | None | False | 256.0 | 0 | 2770369 | 88309 | None | 3.6.1 | Supplying and fixing of modular switch & connected accessories on
existing modular switch plate as per IS 3854 and IS 1293.6A One Way Switch | Each | 166.0 | 166.0 | 20.0 | False | None | None | False | None | False | 3320.0 | 0 | 2770370 | 88309 | None | 3.3.2 | Supplying and fixing surface/flush mounting unbreakable PVC
modular box suitable for mounting modular switch plates with due
groove cutting in Brick/C.C wall, including necessary rawl plugs,
Machine/NF screws etc., complete. 3 Way | Each | 124.0 | 124.0 | 2.0 | False | None | None | False | None | False | 248.0 | 0 | 2770371 | 88309 | None | 3.4.2 | Supplying and flush mounting powder coated / galvanized metal box
suitable for mounting modular switch plates. The box should be firmly
flush mounted after due groove cutting in Brick/Stone/C.C wall 3 Way | Each | 159.0 | 159.0 | 2.0 | False | None | None | False | None | False | 318.0 | 0 | 2770372 | 88309 | None | 3.5.1 | Supplying and fixing superior quality modular switch mounting
polycarbonate plate with necessary supporting back plate with required
nos. of machine screws, bolts nuts etc., complete on the existing
metal/PVC box. 1 to 2 Module | Each | 137.0 | 137.0 | 2.0 | False | None | None | False | None | False | 274.0 | 0 | 2770373 | 88309 | None | 3.9 | Supplying and fixing hylum plastic sheet 3mm thick with necessary
nitches for fixing switches, regulators etc., and fixing on existing
wood or metal box using N. F. screws. | Sq CM | 0.35 | 0.35 | 3500.0 | False | None | None | False | None | False | 1225.0 | 0 | 2770374 | 88309 | None | 6.3.1 | Supplying capacitor type ceiling fan complete with down rod blades,
shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase
AC supply conforming to ISS-374- 1979 and with double ball bearing
system. 48" Sweep (1200 mm) Regular model | Each | 2984.0 | 2984.0 | 8.0 | False | None | None | False | None | False | 23872.0 | 0 | 2770375 | 88309 | None | 11.3.2 | Supplying of .feet -PVC Batten with integrated LED tube . W
with high quality diffuser with Life of 25000 burning hours & 70%
lumen maintenance with CRI greater than 80. Power Input: 220-240V@
50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years
Warranty against any manufacturing defect working under standard
electrical condition. LED light fitting 1 x 4' - 20/22 W | Each | 690.0 | 690.0 | 10.0 | False | None | None | False | None | False | 6900.0 | 0 | 2770376 | 88309 | None | 13.7.1 | Fixing all types and all capacities of fluorescent /false ceiling / spot
light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders
using 23/0.0076" twin twisted PVC insulated wires, required Nos of
round blocks and clamps.On wall/ ceiling / Rafter / Girders | Each | 122.0 | 122.0 | 10.0 | False | None | None | False | None | False | 1220.0 | 0 | 2770377 | 88309 | None | 13.10 | Fixing a ceiling / Wall mounting fan of all capacities and all types to
the existing 'S'' hook with fan regulator to the existing board together
with supplying and fixing 5 A. ceiling rose, necessary length of
23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. | Each | 171.0 | 171.0 | 8.0 | False | None | None | False | None | False | 1368.0 | 0 | 2770378 | 88309 | None | 5.19.12 | Supplying and fixing regular MCB distribution boards on wall/ood
board / flush mounting using required clamps, bolts, nuts etc., with
provision for fixing suitable type capacity MCB's single phase/3
phase/single door with powder coated painting Made out of 14 SWG
MS enclosure. 6 Way TP & N | Each | 4940.0 | 4940.0 | 1.0 | False | None | None | False | None | False | 4940.0 | 0 | 2770379 | 88309 | None | 5.18.1 | Supplying & fixing miniature circuit breakers on existing MCB
distribution boards using necessary fixing materials and 'C' Type
curve, indicator ON/OFF, energy cross-3 with Short circuit breaking
capacity of 10K and complete wiring as required confirming to IEC
60898. 6-32 A SP | Each | 415.0 | 415.0 | 2.0 | False | None | None | False | None | False | 830.0 | 0 | 2770380 | 88309 | None | 5.18.4 | Supplying & fixing miniature circuit breakers on existing MCB
distribution boards using necessary fixing materials and 'C' Type
curve, indicator ON/OFF, energy cross-3 with Short circuit breaking
capacity of 10K and complete wiring as required confirming to IEC
60898. 6-32 A DP | Each | 739.0 | 739.0 | 2.0 | False | None | None | False | None | False | 1478.0 | 0 | 2770381 | 88309 | None | 5.29 | Supplying, fixing and wiring 3 Phase Digital Ammeter /
Voltmeter | Each | 1425.0 | 1425.0 | 1.0 | False | None | None | False | None | False | 1425.0 | 0 | 2770382 | 88309 | None | 5.38 | Supplying and fixing of LED type panel board indicating lamp
with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. | Each | 515.0 | 515.0 | 1.0 | False | None | None | False | None | False | 515.0 | 0 | 2770383 | 88309 | None | 32.10 | 1.1 kV, XLPE or Heat resistant PVC
insulated, PVC exutruted Inner Seath
Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip
thickness and resistivity as per IS-3975 35 Sqmm, 4 Core, (15 GI Strips - 4 x 0.8 mm) | Km | 176070.0 | 176070.0 | 0.045 | False | None | None | False | None | False | 7923.15 | 0 | 2770384 | 88309 | None | 21.06 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using
Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 35 to 95 Sqmm | Km | 31139.0 | 31139.0 | 0.05 | False | None | None | False | None | False | 1556.95 | 0 | 2770385 | 88309 | None | 2.1.3 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet. GROUP Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch | Point | 570.0 | 570.0 | 2.0 | False | None | None | False | None | False | 1140.0 | 0 | 2770386 | 88309 | None | 2.3.4 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming latest amanment 4.0 sq mm | m | 63.0 | 63.0 | 100.0 | False | None | None | False | None | False | 6300.0 | 0 | 2770387 | 88309 | None | 3.14.2 | Supplying And fixing/replacing of 6/16/32A electrical
accessories on existing switch board. 6A Two Way Switch | No | 70.0 | 70.0 | 1.0 | False | None | None | False | None | False | 70.0 | 0 | 2770388 | 88309 | None | 3.5.4 | Supplying and fixing superior quality modular switch mounting
polycarbonate plate with necessary supporting back plate with required
nos. of machine screws, bolts nuts etc., complete on the existing
metal/PVC box. 6 Module | Each | 234.0 | 234.0 | 4.0 | False | None | None | False | None | False | 936.0 | 0 | 2770389 | 88309 | None | 12.58.2 | GI/Copper strips for grounding connections, using necessary fixing
materials as required. GI/Copper strips 25 x 3 mm GI strip | m | 82.0 | 82.0 | 30.0 | False | None | None | False | None | False | 2460.0 | 0 | 2770390 | 88309 | None | 5.42.2 | Fabricating supplying and mounting MS box made out .SWG
suitable for floor /wall mounting, fully weather proof with provision
for better heat dissipation, provided with hinged front cover,
equipped with tamper proof locking arrangements, with suitable
size clamps with necessary cable entry pipe with gland and box
should be finished with 7tanks treatment with powder coated paint
and finally finished with approved colour etc., complete.16 SWG | Sq CM | 0.43 | 0.43 | 3000.0 | False | None | None | False | None | False | 1290.0 | 0 |
|
|
---|