2785714 | 88989 | None | code01 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)-- M25 Design Mix Using 20 mm nominal size graded crushed coarse
aggregates
(RATE INCLUDING CENTERING 70% ON CONCRETE ITEM)
Bbasic rate: 6843.00 | Cum | 13052.34 | 13052.34 | 2.75 | False | None | None | False | None | False | 35893.935 | 0 |
2785715 | 88989 | None | code02 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)-- M25 Design Mix Using 20 mm nominal size graded crushed coarse
aggregates
(RATE INCLUDING CENTERING 70% ON CONCRETE ITEM)
Bbasic rate: 6186.001% of the finished cost of concrete shall be paid extra for every subsequent floors | Cum | 13180.3 | 13180.3 | 3.67 | False | None | None | False | None | False | 48371.701 | 0 |
2785716 | 88989 | None | code03 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse
aggregates
(RATE INCLUDING CENTERING 70% ON CONCRETE ITEM)
Basic Rate: 6217 | Cum | 11858.31 | 11858.31 | 5.22 | False | None | None | False | None | False | 61900.3782 | 0 |
2785717 | 88989 | None | code04 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)-- M25 Design Mix Using 20 mm nominal size graded crushed coarse
aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM)
basic Rate: 6843.00 | Cum | 12284.55 | 12284.55 | 3.74 | False | None | None | False | None | False | 45944.217 | 0 |
2785718 | 88989 | None | code05 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)-- M25 Design Mix Using 20 mm nominal size graded crushed coarse
aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM)
basic Rate: 6843.00 | Cum | 12284.56 | 12284.56 | 3.43 | False | None | None | False | None | False | 42136.0408 | 0 |
2785719 | 88989 | None | code06 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)-- M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM)
Basic Rate: 6843.00 | Cum | 12284.56 | 12284.56 | 5.16 | False | None | None | False | None | False | 63388.3296 | 0 |
2785720 | 88989 | None | code07 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)-- M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 20% ON CONCRETE ITEM)
Basic Rate: 6186.00 | Cum | 12284.56 | 12284.56 | 0.99 | False | None | None | False | None | False | 12161.7144 | 0 |
2785721 | 88989 | None | code08 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM)
Basic Rate: 6843.00 | Cum | 11160.76 | 11160.76 | 2.81 | False | None | None | False | None | False | 31361.7356 | 0 |
2785722 | 88989 | None | code09 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11270.18 | 11270.18 | 1.94 | False | None | None | False | None | False | 21864.1492 | 0 |
2785723 | 88989 | None | code10 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)-- M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Basic Rate: 6843.00 | Cum | 11516.77 | 11516.77 | 5.34 | False | None | None | False | None | False | 61499.5518 | 0 |
2785724 | 88989 | None | code11 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications | Sqm | 1441.0 | 1441.0 | 439.54 | False | None | None | False | None | False | 633377.14 | 0 |
2785725 | 88989 | None | code12 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications | Sqm | 1484.23 | 1484.23 | 223.25 | False | None | None | False | None | False | 331354.3475 | 0 |
2785726 | 88989 | None | code13 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)-- M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
(RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Basic rate: 6843.00 | Cum | 11516.77 | 11516.77 | 31.7 | False | None | None | False | None | False | 365081.609 | 0 |
2785727 | 88989 | None | code14 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)-- M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
(RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Basic rate:6843.00 | Cum | 11629.68 | 11629.68 | 5.55 | False | None | None | False | None | False | 64544.724 | 0 |
2785728 | 88989 | None | code15 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)-- M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
(RATE INCLUDING CENTERING 45% ON CONCRETE ITEM)
Basic RATE:6843.00 | Cum | 11132.88 | 11132.88 | 5.23 | False | None | None | False | None | False | 58224.9624 | 0 |
2785729 | 88989 | None | code16 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)-- M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
(RATE INCLUDING CENTERING 45% ON CONCRETE ITEM)
Basic RATE:6843.00 | Cum | 11242.02 | 11242.02 | 0.29 | False | None | None | False | None | False | 3260.1858 | 0 |
2785730 | 88989 | None | code17 | Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | Tonne | 100370.75 | 100370.75 | 6.09 | False | None | None | False | None | False | 611257.8675 | 0 |
2785731 | 88989 | None | code18 | Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | Tonne | 101354.78 | 101354.78 | 3.18 | False | None | None | False | None | False | 322308.2004 | 0 |
2785732 | 88989 | None | code19 | Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 111751.2 | 111751.2 | 1.14 | False | None | None | False | None | False | 127396.368 | 0 |
2785733 | 88989 | None | code20 | Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 112846.8 | 112846.8 | 0.14 | False | None | None | False | None | False | 15798.552 | 0 |
2785734 | 88989 | None | code21 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 7555.55 | 7555.55 | 69.6 | False | None | None | False | None | False | 525866.28 | 0 |
2785735 | 88989 | None | code22 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 7629.62 | 7629.62 | 9.72 | False | None | None | False | None | False | 74159.9064 | 0 |
2785736 | 88989 | None | code23 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-35 mm thick both side commercial | Sqm | 3727.28 | 3727.28 | 35.18 | False | None | None | False | None | False | 131125.7104 | 0 |
2785737 | 88989 | None | code24 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-35 mm thick both side commercial | Sqm | 3763.83 | 3763.83 | 4.0 | False | None | None | False | None | False | 15055.32 | 0 |
2785738 | 88989 | None | code25 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kgs | 188.5 | 188.5 | 1461.6 | False | None | None | False | None | False | 275511.6 | 0 |
2785739 | 88989 | None | code26 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kgs | 190.34 | 190.34 | 907.74 | False | None | None | False | None | False | 172779.2316 | 0 |
2785740 | 88989 | None | code27 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineerin-Charge. | Kgs | 207.34 | 207.34 | 808.62 | False | None | None | False | None | False | 167659.2708 | 0 |
2785741 | 88989 | None | code28 | Providing 12 mm cement plaster with Cement mortar 1:3 (1cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete | Sqm | 362.41 | 362.41 | 425.74 | False | None | None | False | None | False | 154292.4334 | 0 |
2785742 | 88989 | None | code29 | Providing 12 mm cement plaster with Cement mortar 1:3 (1cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete | Sqm | 365.96 | 365.96 | 64.9957 | False | None | None | False | None | False | 23785.826372 | 0 |
2785743 | 88989 | None | code30 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per
directions of Engineer-in-charge | Sqm | 410.65 | 410.65 | 1015.52 | False | None | None | False | None | False | 417023.288 | 0 |
2785744 | 88989 | None | code31 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per
directions of Engineer-in-charge | Sqm | 414.68 | 414.68 | 106.8 | False | None | None | False | None | False | 44287.824 | 0 |
2785745 | 88989 | None | code32 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in- charge. | Sqm | 431.97 | 431.97 | 447.12 | False | None | None | False | None | False | 193142.4264 | 0 |
2785746 | 88989 | None | code33 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in- charge. | Sqm | 436.21 | 436.21 | 291.92 | False | None | None | False | None | False | 127338.4232 | 0 |
2785747 | 88989 | None | code34 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 916.67 | 916.67 | 70.53 | False | None | None | False | None | False | 64652.7351 | 0 |
2785748 | 88989 | None | code35 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 925.66 | 925.66 | 382.61 | False | None | None | False | None | False | 354166.7726 | 0 |
2785749 | 88989 | None | code36 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. | Sqm | 2263.07 | 2263.07 | 16.68 | False | None | None | False | None | False | 37748.0076 | 0 |
2785750 | 88989 | None | code37 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. | Sqm | 3199.94 | 3199.94 | 105.44 | False | None | None | False | None | False | 337401.6736 | 0 |
2785751 | 88989 | None | code38 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. | Sqm | 3231.32 | 3231.32 | 44.81 | False | None | None | False | None | False | 144795.4492 | 0 |
2785752 | 88989 | None | code39 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. | Sqm | 368.02 | 368.02 | 44.98 | False | None | None | False | None | False | 16553.5396 | 0 |
2785753 | 88989 | None | code40 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. | Sqm | 371.62 | 371.62 | 2.6 | False | None | None | False | None | False | 966.212 | 0 |
2785754 | 88989 | None | code41 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.-- Size of Tile 800x800 mm | Sqm | 1410.35 | 1410.35 | 328.27 | False | None | None | False | None | False | 462975.5945 | 0 |
2785755 | 88989 | None | code42 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.-- Size of Tile 800x800 mm | Sqm | 1424.18 | 1424.18 | 44.67 | False | None | None | False | None | False | 63618.1206 | 0 |
2785756 | 88989 | None | code43 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete | Sqm | 997.46 | 997.46 | 76.1 | False | None | None | False | None | False | 75906.706 | 0 |
2785757 | 88989 | None | code44 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. | Sqm | 1240.93 | 1240.93 | 75.65 | False | None | None | False | None | False | 93876.3545 | 0 |
2785758 | 88989 | None | code45 | Providing and laying flooring and steps machine cut granite slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with ce ment mortar 1:3 over existing cement concrete bed , including cost of materials, mortar labour, curing complete
as per specifications. | Sqm | 4801.04 | 4801.04 | 25.92 | False | None | None | False | None | False | 124442.9568 | 0 |
2785759 | 88989 | None | code46 | Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, griding the edge to half/full round wherever required, labour, curing complete as per specification. | Sqm | 1055.96 | 1055.96 | 318.26 | False | None | None | False | None | False | 336069.8296 | 0 |
2785760 | 88989 | None | code47 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 112.2 | 112.2 | 1441.26 | False | None | None | False | None | False | 161709.372 | 0 |
2785761 | 88989 | None | code48 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 113.3 | 113.3 | 171.14 | False | None | None | False | None | False | 19390.162 | 0 |
2785762 | 88989 | None | code49 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per
specifications and as per directions of Engineer-in-charge. | Sqm | 177.28 | 177.28 | 425.74 | False | None | None | False | None | False | 75475.1872 | 0 |
2785763 | 88989 | None | code50 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per
specifications and as per directions of Engineer-in-charge. | Sqm | 173.8 | 173.8 | 64.34 | False | None | None | False | None | False | 11182.292 | 0 |
2785764 | 88989 | None | code51 | Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 177.28 | 177.28 | 1015.52 | False | None | None | False | None | False | 180031.3856 | 0 |
2785765 | 88989 | None | code52 | Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 173.8 | 173.8 | 106.8 | False | None | None | False | None | False | 18561.84 | 0 |
2785766 | 88989 | None | code53 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as
per specifications and as per directions of Engineer-in-charge. | Sqm | 195.23 | 195.23 | 447.12 | False | None | None | False | None | False | 87291.2376 | 0 |
2785767 | 88989 | None | code54 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as
per specifications and as per directions of Engineer-in-charge. | Sqm | 197.14 | 197.14 | 291.92 | False | None | None | False | None | False | 57549.1088 | 0 |
2785768 | 88989 | None | code55 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 187.37 | 187.37 | 69.6 | False | None | None | False | None | False | 13040.952 | 0 |
2785769 | 88989 | None | code56 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 189.21 | 189.21 | 818.34 | False | None | None | False | None | False | 154838.1114 | 0 |
2785770 | 88989 | None | code57 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge. | Sqm | 62.83 | 62.83 | 87.94 | False | None | None | False | None | False | 5525.2702 | 0 |
2785771 | 88989 | None | code58 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge. | Sqm | 63.45 | 63.45 | 9.99 | False | None | None | False | None | False | 633.8655 | 0 |
2785772 | 88989 | None | code59 | Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 151.47 | 151.47 | 87.94 | False | None | None | False | None | False | 13320.2718 | 0 |
2785773 | 88989 | None | code60 | Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 152.96 | 152.96 | 9.99 | False | None | None | False | None | False | 1528.0704 | 0 |
2785774 | 88989 | None | code61 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges
of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 633.93 | 633.93 | 126.25 | False | None | None | False | None | False | 80033.6625 | 0 |
2785775 | 88989 | None | code62 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:-PVC pipes 110mm dia., 6 kg/sqcm | Mtr | 461.14 | 461.14 | 119.25 | False | None | None | False | None | False | 54990.945 | 0 |
2785776 | 88989 | None | code63 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:-PVC pipes 110mm dia., 6 kg/sqcm | Mtr | 446.4 | 446.4 | 171.0 | False | None | None | False | None | False | 76334.4 | 0 |
2785777 | 88989 | None | code64 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 916.67 | 916.67 | 76.1 | False | None | None | False | None | False | 69758.587 | 0 |
2785778 | 88989 | None | code65 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete | Nos | 143.0 | 143.0 | 8.0 | False | None | None | False | None | False | 1144.0 | 0 |
2785779 | 88989 | None | code66 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete | Nos | 143.0 | 143.0 | 5.0 | False | None | None | False | None | False | 715.0 | 0 |
2785780 | 88989 | None | code67 | Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. | Nos | 64.9 | 64.9 | 5.0 | False | None | None | False | None | False | 324.5 | 0 |
2785781 | 88989 | None | code68 | Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. | Nos | 64.9 | 64.9 | 2.0 | False | None | None | False | None | False | 129.8 | 0 |
2785782 | 88989 | None | code69 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : | Nos | 100.1 | 100.1 | 80.0 | False | None | None | False | None | False | 8008.0 | 0 |
2785783 | 88989 | None | code70 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : | Nos | 100.1 | 100.1 | 8.0 | False | None | None | False | None | False | 800.8 | 0 |
2785784 | 88989 | None | code71 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : | Nos | 302.5 | 302.5 | 12.0 | False | None | None | False | None | False | 3630.0 | 0 |
2785785 | 88989 | None | code72 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : | Nos | 302.5 | 302.5 | 3.0 | False | None | None | False | None | False | 907.5 | 0 |
2785786 | 88989 | None | code73 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : | Nos | 478.5 | 478.5 | 2.0 | False | None | None | False | None | False | 957.0 | 0 |
2785787 | 88989 | None | code74 | Providing and fixing bright finished brass handles with screws etc.complete:Brass handles 125 mm with plate 175x32 mm | Nos | 273.9 | 273.9 | 10.0 | False | None | None | False | None | False | 2739.0 | 0 |
2785788 | 88989 | None | code75 | Providing and fixing bright finished brass handles with screws etc.complete:Brass handles 125 mm with plate 175x32 mm | Nos | 273.9 | 273.9 | 52.0 | False | None | None | False | None | False | 14242.8 | 0 |
2785789 | 88989 | None | code76 | Providing and fixing bright finished brass handles with screws etc.complete: Brass handles 100 mm with plate 150x32 mm | Nos | 254.1 | 254.1 | 10.0 | False | None | None | False | None | False | 2541.0 | 0 |
2785790 | 88989 | None | code77 | Providing and fixing bright finished brass handles with screws etc.complete: Brass handles 100 mm with plate 150x32 mm | Nos | 254.1 | 254.1 | 4.0 | False | None | None | False | None | False | 1016.4 | 0 |
2785791 | 88989 | None | code78 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. | Nos | 1157.2 | 1157.2 | 5.0 | False | None | None | False | None | False | 5786.0 | 0 |
2785792 | 88989 | None | code79 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. | Nos | 1157.2 | 1157.2 | 4.0 | False | None | None | False | None | False | 4628.8 | 0 |
2785793 | 88989 | None | code80 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 166.55 | 166.55 | 7466.64 | False | None | None | False | None | False | 1243568.892 | 0 |
2785794 | 88989 | None | code81 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required | Sqm | 643.54 | 643.54 | 585.04 | False | None | None | False | None | False | 376496.6416 | 0 |
2785795 | 88989 | None | code82 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Kgs | 189.21 | 189.21 | 194.13 | False | None | None | False | None | False | 36731.3373 | 0 |
2785796 | 88989 | None | code83 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.-By Mechanical Means using Dozer-In area of thorny jungle | Sqm | 532.4 | 532.4 | 2.47 | False | None | None | False | None | False | 1315.028 | 0 |
2785797 | 88989 | None | code84 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m HARD SOIL 90% OF THE TOTAL QUANTITY | Cum | 112.2 | 112.2 | 97.34 | False | None | None | False | None | False | 10921.548 | 0 |
2785798 | 88989 | None | code85 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m- In ordinary/soft rock without blasting upto 1.5 m depth Soft rock 10% OF THE TOTAL QUANTITY | Cum | 399.3 | 399.3 | 10.82 | False | None | None | False | None | False | 4320.426 | 0 |
2785799 | 88989 | None | code86 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse
aggregates | Cum | 6230.4 | 6230.4 | 15.55 | False | None | None | False | None | False | 96882.72 | 0 |
2785800 | 88989 | None | code87 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
(RATE INCLUDING CENTERING 8% ON CONCRETE ITEM)
Basic rate: 5979 | Cum | 6872.8 | 6872.8 | 16.7 | False | None | None | False | None | False | 114775.76 | 0 |
2785801 | 88989 | None | code88 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other M25 Design Mix Using 20 mm nominal size graded
crushed coarse aggregates
(RATE INCLUDING CENTERING 20% ON CONCRETE ITEM)
Basic rate:5992. | Cum | 6969.6 | 6969.6 | 4.49 | False | None | None | False | None | False | 31293.504 | 0 |
2785802 | 88989 | None | code89 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 292.6 | 292.6 | 87.74 | False | None | None | False | None | False | 25672.724 | 0 |
2785803 | 88989 | None | code90 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)-- M25 Design Mix Using 20 mm nominal size graded crushed coarse
aggregates
(RATE INCLUDING CENTERING 10% ON CONCRETE ITEM)
Bbasic rate: 6186.00 | Cum | 12796.41 | 12796.41 | 7.42 | False | None | None | False | None | False | 94949.3622 | 0 |
2785804 | 88989 | None | code91 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) | Cum | 11824.01 | 11824.01 | 12.47 | False | None | None | False | None | False | 147445.4047 | 0 |
2785805 | 88989 | None | code92 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10941.92 | 10941.92 | 0.89 | False | None | None | False | None | False | 9738.3088 | 0 |
2785806 | 88989 | None | code93 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications | Sqm | 1441.0 | 1441.0 | 118.49 | False | None | None | False | None | False | 170744.09 | 0 |
2785807 | 88989 | None | code94 | Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | Tonne | 98402.7 | 98402.7 | 3.63 | False | None | None | False | None | False | 357201.801 | 0 |
2785808 | 88989 | None | code95 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kgs | 149.6 | 149.6 | 675.0 | False | None | None | False | None | False | 100980.0 | 0 |
2785809 | 88989 | None | code96 | Fencing with G.I. barbed wire Angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used. | m | 19.8 | 19.8 | 324.24 | False | None | None | False | None | False | 6419.952 | 0 |
2785810 | 88989 | None | code97 | 11.57.2 - Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete. ISA 75x75x6mm | Kg | 124.3 | 124.3 | 164.43 | False | None | None | False | None | False | 20438.649 | 0 |
2785811 | 88989 | None | code98 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in- charge. | Sqm | 423.5 | 423.5 | 272.53 | False | None | None | False | None | False | 115416.455 | 0 |
2785812 | 88989 | None | code99 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as
per specifications and as per directions of Engineer-in-charge. | Sqm | 191.4 | 191.4 | 272.53 | False | None | None | False | None | False | 52162.242 | 0 |
2785813 | 88989 | None | code100 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 183.7 | 183.7 | 18.0 | False | None | None | False | None | False | 3306.6 | 0 |
2785814 | 88989 | None | code101 | Providing and laying heavy duty cobble stones 75mm thick interlock pavers, using cement and course sand for manufacture of blocks of approved size, shape and colour with a minimum compressive strength of 281 kg per m2 over 50mm thick sand bed ( average thickness ) and compacting with plate vibrator having 3 tons compaction force thereby forcing part of sand underneath to come up in between joints, final compaction of paver surface joints into its final level, including cost of materials, labour and Usage charges of machinery complete as per specifications. | Sqm | 1259.5 | 1259.5 | 163.18 | False | None | None | False | None | False | 205525.21 | 0 |
2785815 | 88989 | None | code102 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required-White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. | Nos | 5372.4 | 5372.4 | 4.0 | False | None | None | False | None | False | 21489.6 | 0 |
2785816 | 88989 | None | code103 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings &
C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid | Nos | 6574.7 | 6574.7 | 1.0 | False | None | None | False | None | False | 6574.7 | 0 |
2785817 | 88989 | None | code104 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer | Nos | 4533.1 | 4533.1 | 13.0 | False | None | None | False | None | False | 58930.3 | 0 |
2785818 | 88989 | None | code105 | Providing and fixing 100 mm sand cast Iron grating for gully
trap. | Nos | 51.7 | 51.7 | 8.0 | False | None | None | False | None | False | 413.6 | 0 |
2785819 | 88989 | None | code106 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. | Nos | 797.5 | 797.5 | 13.0 | False | None | None | False | None | False | 10367.5 | 0 |
2785820 | 88989 | None | code107 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than
810 g. | Nos | 930.6 | 930.6 | 13.0 | False | None | None | False | None | False | 12097.8 | 0 |
2785821 | 88989 | None | code108 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) -25 mm nominal bore | Mtr | 603.9 | 603.9 | 4.0 | False | None | None | False | None | False | 2415.6 | 0 |
2785822 | 88989 | None | code109 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) -32 mm nominal bore | Mtr | 657.8 | 657.8 | 4.0 | False | None | None | False | None | False | 2631.2 | 0 |
2785823 | 88989 | None | code110 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) -40 mm nominal bore | Mtr | 772.2 | 772.2 | 4.0 | False | None | None | False | None | False | 3088.8 | 0 |
2785824 | 88989 | None | code111 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) -50 mm nominal bore | Mtr | 940.5 | 940.5 | 4.0 | False | None | None | False | None | False | 3762.0 | 0 |
2785825 | 88989 | None | code112 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) -65 mm nominal bore | Mtr | 1552.1 | 1552.1 | 4.0 | False | None | None | False | None | False | 6208.4 | 0 |
2785826 | 88989 | None | code113 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) -80 mm nominal bore | Mtr | 2284.7 | 2284.7 | 5.0 | False | None | None | False | None | False | 11423.5 | 0 |
2785827 | 88989 | None | code114 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass
screws and washers complete. | Nos | 1342.0 | 1342.0 | 17.0 | False | None | None | False | None | False | 22814.0 | 0 |
2785828 | 88989 | None | code115 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190g. | Nos | 545.6 | 545.6 | 17.0 | False | None | None | False | None | False | 9275.2 | 0 |
2785829 | 88989 | None | code116 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:-PVC pipes 160mm dia., 6 kg/sqcm & class 3-(basic rate 599) | m | 658.9 | 658.9 | 50.0 | False | None | None | False | None | False | 32945.0 | 0 |
2785830 | 88989 | None | code117 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:-PVC pipes 110mm dia., 6 kg/sqcm & class 3-(basic rate 394) | m | 452.1 | 452.1 | 51.0 | False | None | None | False | None | False | 23057.1 | 0 |
2785831 | 88989 | None | code118 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:-PVC pipes 90mm dia., 6 kg/sqcm & class 3 (basic rate 281) | m | 309.1 | 309.1 | 40.0 | False | None | None | False | None | False | 12364.0 | 0 |
2785832 | 88989 | None | code119 | Providing and fixing Chorinated Poly Venly Cloride (CPVC) pipes conforming to IS15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr. spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (concealed work including cutting chases and good the walls
etc), For 50 mm dia | m | 843.7 | 843.7 | 50.0 | False | None | None | False | None | False | 42185.0 | 0 |
2785833 | 88989 | None | code120 | Providing and fixing Chorinated Poly Venly Cloride (CPVC) pipes conforming to IS15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr. spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (concealed work including cutting chases and good the walls | m | 432.3 | 432.3 | 25.0 | False | None | None | False | None | False | 10807.5 | 0 |
2785834 | 88989 | None | code121 | Providing and fixing Chorinated Poly Venly Cloride (CPVC) pipes conforming to IS15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr. spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (concealed work including cutting chases and good the walls etc), For 25 mm dia | m | 347.6 | 347.6 | 60.0 | False | None | None | False | None | False | 20856.0 | 0 |
2785835 | 88989 | None | code122 | Providing and fixing Chorinated Poly Venly Cloride (CPVC) pipes conforming to IS15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr. spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (concealed work including cutting chases and good the walls etc), For 20 mm dia | Nos | 266.2 | 266.2 | 70.0 | False | None | None | False | None | False | 18634.0 | 0 |
2785836 | 88989 | None | code123 | Providing PVC-U INDIVIDUAL U.G.D House service connection (which shall be laid from inside the customer property ) which includes: a) Supply of PVC-U pipe (b) providing and fixing of 315 mm dia the PE Inspection chambres with lid consisting of inlet & outlet arrangements with base, riser of min. 0.42 m depth which includes earth work, fixing in CC- 1:2:4 with appurtenances., complete. (c) civil works like Earthwork excavation for the pipeline trenches for laying of PVC-U pipes for the house connections in all types of soils , disintegrated rock,soft rock, hard rock, including cutting of any road using , crossing drains, compound, Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, c.c. wood work, steel work, including T & P and scaffolding wherever necessary sorting the dismantled material, disposal of unserviceable and stacking the serviceable material with all lifts and lead , restoring the damaged portions inside or outside the property premises, refilling the portions of trenches that are dug open including linking to existing sewer network with appurtenances. complete.Supply and fixing of SFRC machinhole cover (Medium Duty) made as per IS to suit existing damaged machinhole cover after removing the debries from inside and outside the existing machinhole etc. with all lead
and lifts. 110 mm dia | Nos | 8605.3 | 8605.3 | 10.0 | False | None | None | False | None | False | 86053.0 | 0 |
2785837 | 88989 | None | code124 | KSRB 13-11 : Providing and placing on terrace, polyethylene water storage tanks as per IS 12701 : 1996 with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flow pipes, including cost of all materials, labour, transport charges, HOM and testing complete as per specifications.
Specification No.KBS 13.22 | Ltr | 8.8 | 8.8 | 4000.0 | False | None | None | False | None | False | 35200.0 | 0 |
2785838 | 88989 | None | code125 | Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. and running before Concreting the Slab. The Conduit should be tied to the reenforcement Rods by using binding wires and the unused ways of Junction boxes should be covered using PVC End enclosures .run with 18 SWG GI finish wire wherever it is necessory - 19/20mm Dia 2mm Thick | Mtr | 66.0 | 66.0 | 650.0 | False | None | None | False | None | False | 42900.0 | 0 |
2785839 | 88989 | None | code126 | Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. and running before Concreting the Slab. The Conduit should be tied to the reenforcement Rods by using binding wires and the unused ways of Junction boxes should be covered using PVC End enclosures .run with 18 SWG GI finish wire wherever it is necessory - 25mm dia 2mm Thick | Mtr | 78.0 | 78.0 | 400.0 | False | None | None | False | None | False | 31200.0 | 0 |
2785840 | 88989 | None | code127 | Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. and running before Concreting the Slab. The Conduit should be tied to the reenforcement Rods by using binding wires and the unused ways of Junction boxes should be covered using PVC End enclosures .run with 18 SWG GI finish wire wherever it is necessory - 32mm dia 2.5mm thick | Mtr | 103.0 | 103.0 | 10.0 | False | None | None | False | None | False | 1030.0 | 0 |
2785841 | 88989 | None | code128 | Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. by groove cutting in the wall and fixing by bracing U or J hooks and plastering upto wall surface and .run with 18 SWG GI finish wire wherever it is necessory- 19/20mm Dia 2mm Thick | Mtr | 68.0 | 68.0 | 220.0 | False | None | None | False | None | False | 14960.0 | 0 |
2785842 | 88989 | None | code129 | Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. by groove cutting in the wall and fixing by bracing U or J hooks and plastering upto wall surface and .run with 18 SWG GI finish wire wherever it is necessory- 25mm dia 2mm Thick | Mtr | 79.0 | 79.0 | 135.0 | False | None | None | False | None | False | 10665.0 | 0 |
2785843 | 88989 | None | code130 | Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. by groove cutting in the wall and fixing by bracing U or J hooks and plastering upto wall surface and .run with 18 SWG GI finish wire wherever it is necessory- 32mm dia 2.5mm thick | Mtr | 99.0 | 99.0 | 10.0 | False | None | None | False | None | False | 990.0 | 0 |
2785844 | 88989 | None | code131 | Supplying and fixing PVC/ Metal Conduit Deep Junction Boxes - 19/20 mm Deep Junction Box | Mtr | 49.0 | 49.0 | 100.0 | False | None | None | False | None | False | 4900.0 | 0 |
2785845 | 88989 | None | code132 | Supplying and fixing PVC/ Metal Conduit Deep Junction Boxes - 25 mm Deep Junction Box | Mtr | 56.0 | 56.0 | 50.0 | False | None | None | False | None | False | 2800.0 | 0 |
2785846 | 88989 | None | code133 | Supplying and fixing PVC/ Metal Conduit Deep Junction Boxes - 32 mm Deep Junction Box | Mtr | 61.0 | 61.0 | 10.0 | False | None | None | False | None | False | 610.0 | 0 |
2785847 | 88989 | None | code134 | Supplying and fixing PVC Casing and capping on the wall or ceiling using materials like bend , screws at an interval 0f 300 mm etc- 20mm | Mtr | 28.0 | 28.0 | 100.0 | False | None | None | False | None | False | 2800.0 | 0 |
2785848 | 88989 | None | code135 | Supplying and fixing PVC Casing and capping on the wall or ceiling using materials like bend , screws at an interval 0f 300 mm etc- 25mm | Mtr | 35.0 | 35.0 | 80.0 | False | None | None | False | None | False | 2800.0 | 0 |
2785849 | 88989 | None | code136 | Supplying and fixing PVC Casing and capping on the wall or ceiling using materials like bend , screws at an interval 0f 300 mm etc- 25mm | Mtr | 43.0 | 43.0 | 10.0 | False | None | None | False | None | False | 430.0 | 0 |
2785850 | 88989 | None | code137 | Supplying PVC /GI flexible conduit pipe …. Mm dia fixing on surface cover inverted tapared wodden plugs or phill plugs or rawl plugs and clamped using heavy guage saddles in an interval of 300 mm using NF screws and on the eaiter end of the pipe terminated properly- 20mm | Mtr | 19.0 | 19.0 | 75.0 | False | None | None | False | None | False | 1425.0 | 0 |
2785851 | 88989 | None | code138 | Supplying PVC /GI flexible conduit pipe …. Mm dia fixing on surface cover inverted tapared wodden plugs or phill plugs or rawl plugs and clamped using heavy guage saddles in an interval of 300 mm using NF screws and on the eaiter end of the pipe terminated properly- 25mm | Mtr | 22.0 | 22.0 | 60.0 | False | None | None | False | None | False | 1320.0 | 0 |
2785852 | 88989 | None | code139 | Supply & Fixing of Metal fan box with round Hook | Each | 117.0 | 117.0 | 15.0 | False | None | None | False | None | False | 1755.0 | 0 |
2785853 | 88989 | None | code140 | Supplying and wiring adopting loop system in existing PVC conduit/casing capping, using copper FRLS PVC insulated multi strand 2 x 1.5 sq.mm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block complete for each outlet. Make : KEI / Polycab/ Finolex - Short point upto 3 Mtd. From Tapping point to outlet via switch box. | Point | 269.0 | 269.0 | 30.0 | False | None | None | False | None | False | 8070.0 | 0 |
2785854 | 88989 | None | code141 | Supplying and wiring adopting loop system in existing PVC conduit/casing capping, using copper FRLS PVC insulated multi strand 2 x 1.5 sq.mm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block complete for each outlet. Make : KEI / Polycab/ Finolex - Medium point above 3 Mts upto 6 Mts. From tapping point to outlet via switch box.. | Point | 379.0 | 379.0 | 7.0 | False | None | None | False | None | False | 2653.0 | 0 |
2785855 | 88989 | None | code142 | Supplying and wiring adopting loop system in existing PVC conduit/casing capping, using copper FRLS PVC insulated multi strand 2 x 1.5 sq.mm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block complete for each outlet. Make : KEI / Polycab/ Finolex - Long point above 6 Mts. Upto 10 Mts. From tapping of point to outlet via switch box. . | Point | 555.0 | 555.0 | 35.0 | False | None | None | False | None | False | 19425.0 | 0 |
2785856 | 88989 | None | code143 | Supplying and wiring adopting loop system in existing PVC conduit/casing capping, using copper FRLS PVC insulated multi strand 2 x 1.5 sq.mm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block complete for each outlet. Make : KEI / Polycab/ Finolex - Two outlet in a row above 3 Mts upto 6 Mts, from tapping point to outlet via switch box. | Point | 677.0 | 677.0 | 2.0 | False | None | None | False | None | False | 1354.0 | 0 |
2785857 | 88989 | None | code144 | Supplying and wiring adopting loop system in existing PVC conduit/casing capping, using copper FRLS PVC insulated multi strand 2 x 1.5 sq.mm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block complete for each outlet. Make : KEI / Polycab/ Finolex - Three outlet in a row, above 6 Mts. Upto 10 Mts. From tapping point to outlet via switch box. | Point | 989.0 | 989.0 | 6.0 | False | None | None | False | None | False | 5934.0 | 0 |
2785858 | 88989 | None | code145 | Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring- 1.5 sqmm | Mtr | 26.0 | 26.0 | 1600.0 | False | None | None | False | None | False | 41600.0 | 0 |
2785859 | 88989 | None | code146 | Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring- 2.5 sqmm | Mtr | 42.0 | 42.0 | 1800.0 | False | None | None | False | None | False | 75600.0 | 0 |
2785860 | 88989 | None | code147 | Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring- 4 sqmm | Mtr | 63.0 | 63.0 | 300.0 | False | None | None | False | None | False | 18900.0 | 0 |
2785861 | 88989 | None | code148 | Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring- 6 sqmm | Mtr | 92.0 | 92.0 | 120.0 | False | None | None | False | None | False | 11040.0 | 0 |
2785862 | 88989 | None | code149 | Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring- 10sqmm | Mtr | 167.0 | 167.0 | 100.0 | False | None | None | False | None | False | 16700.0 | 0 |
2785863 | 88989 | None | code150 | Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring- 16sqmm | Mtr | 318.0 | 318.0 | 50.0 | False | None | None | False | None | False | 15900.0 | 0 |
2785864 | 88989 | None | code151 | Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall Make : Anchor / Schneider / Legrand- 1-2 way | Each | 138.0 | 138.0 | 24.0 | False | None | None | False | None | False | 3312.0 | 0 |
2785865 | 88989 | None | code152 | Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall Make : Anchor / Schneider / Legrand- 3 way | Each | 159.0 | 159.0 | 10.0 | False | None | None | False | None | False | 1590.0 | 0 |
2785866 | 88989 | None | code153 | Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall Make : Anchor / Schneider / Legrand- 4-5 way | Each | 177.0 | 177.0 | 35.0 | False | None | None | False | None | False | 6195.0 | 0 |
2785867 | 88989 | None | code154 | Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall Make : Anchor / Schneider / Legrand- 6 way | Each | 220.0 | 220.0 | 30.0 | False | None | None | False | None | False | 6600.0 | 0 |
2785868 | 88989 | None | code155 | Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall Make : Anchor / Schneider / Legrand- 8 way | Each | 261.0 | 261.0 | 12.0 | False | None | None | False | None | False | 3132.0 | 0 |
2785869 | 88989 | None | code156 | Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall Make : Anchor / Schneider / Legrand- 12way | Each | 319.0 | 319.0 | 6.0 | False | None | None | False | None | False | 1914.0 | 0 |
2785870 | 88989 | None | code157 | Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall Make : Anchor / Schneider / Legrand- 16way | Each | 363.0 | 363.0 | 2.0 | False | None | None | False | None | False | 726.0 | 0 |
2785871 | 88989 | None | code158 | Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box - 1-2 way | Each | 137.0 | 137.0 | 24.0 | False | None | None | False | None | False | 3288.0 | 0 |
2785872 | 88989 | None | code159 | Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box - 3 way | Each | 161.0 | 161.0 | 10.0 | False | None | None | False | None | False | 1610.0 | 0 |
2785873 | 88989 | None | code160 | Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box - 4-5 way | Each | 175.0 | 175.0 | 35.0 | False | None | None | False | None | False | 6125.0 | 0 |
2785874 | 88989 | None | code161 | Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box - 6 way | Each | 234.0 | 234.0 | 30.0 | False | None | None | False | None | False | 7020.0 | 0 |
2785875 | 88989 | None | code162 | Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box - 8 way | Each | 284.0 | 284.0 | 12.0 | False | None | None | False | None | False | 3408.0 | 0 |
2785876 | 88989 | None | code163 | Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box - 10-12 way | Each | 344.0 | 344.0 | 6.0 | False | None | None | False | None | False | 2064.0 | 0 |
2785877 | 88989 | None | code164 | Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box - 16 way | Each | 397.0 | 397.0 | 2.0 | False | None | None | False | None | False | 794.0 | 0 |
2785878 | 88989 | None | code165 | Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate - 6 Amp one way | Each | 102.0 | 102.0 | 185.0 | False | None | None | False | None | False | 18870.0 | 0 |
2785879 | 88989 | None | code166 | Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate - 6 Amp two way | Each | 166.0 | 166.0 | 2.0 | False | None | None | False | None | False | 332.0 | 0 |
2785880 | 88989 | None | code167 | Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate - 6 Amp socket | Each | 171.0 | 171.0 | 80.0 | False | None | None | False | None | False | 13680.0 | 0 |
2785881 | 88989 | None | code168 | Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate - Stepped Fan Regulator | Each | 357.0 | 357.0 | 15.0 | False | None | None | False | None | False | 5355.0 | 0 |
2785882 | 88989 | None | code169 | Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate - 16 Amps 1 way switch | Each | 180.0 | 180.0 | 15.0 | False | None | None | False | None | False | 2700.0 | 0 |
2785883 | 88989 | None | code170 | Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate - 6 Amps Bell Push | Each | 177.0 | 177.0 | 10.0 | False | None | None | False | None | False | 1770.0 | 0 |
2785884 | 88989 | None | code171 | Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate - 32 Amps DP Switch | Each | 326.0 | 326.0 | 4.0 | False | None | None | False | None | False | 1304.0 | 0 |
2785885 | 88989 | None | code172 | Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate - 6/16 Amps universal socket | Each | 236.0 | 236.0 | 15.0 | False | None | None | False | None | False | 3540.0 | 0 |
2785886 | 88989 | None | code173 | LUMINERIES & LIGHT FIXTURES & ACCESSORIES Make : Panasonic/Phillips / Crompton - Led Light Fixture 2 feet - 9/10 W | Each | 551.0 | 551.0 | 18.0 | False | None | None | False | None | False | 9918.0 | 0 |
2785887 | 88989 | None | code174 | LUMINERIES & LIGHT FIXTURES & ACCESSORIES Make : Panasonic/Phillips / Crompton - Led Light Fixture 4 feet - 20/22 W | Each | 690.0 | 690.0 | 40.0 | False | None | None | False | None | False | 27600.0 | 0 |
2785888 | 88989 | None | code175 | Supply of recess mounted rolling type LED square or round Light 12 watta | Each | 885.0 | 885.0 | 15.0 | False | None | None | False | None | False | 13275.0 | 0 |
2785889 | 88989 | None | code176 | Supplying and fixing regular MCB distribution Boards on Wall / wood board /flush mounting using required clamps bolts nuts etc with provision for fixing suitable type capacity MCB single phase / 3 phase / single door with powder coated paiting, Double door - 12Way SP &N | Nos | 2329.0 | 2329.0 | 2.0 | False | None | None | False | None | False | 4658.0 | 0 |
2785890 | 88989 | None | code177 | Supplying and fixing regular MCB distribution Boards on Wall / wood board /flush mounting using required clamps bolts nuts etc with provision for fixing suitable type capacity MCB single phase / 3 phase / single door with powder coated paiting, Double door - 6Way TP &N | Nos | 4940.0 | 4940.0 | 1.0 | False | None | None | False | None | False | 4940.0 | 0 |
2785891 | 88989 | None | code178 | Supplying fixing & wiring earth leakage miniature circuit breaker (ELMCB) 240 / 450 V up to 300mA sensitivity on Existing / panel Board - 32 - 40 Amps 2 pole | Nos | 4559.0 | 4559.0 | 5.0 | False | None | None | False | None | False | 22795.0 | 0 |
2785892 | 88989 | None | code179 | Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898 - 5 - 32 Amp SP | Nos | 210.0 | 210.0 | 40.0 | False | None | None | False | None | False | 8400.0 | 0 |
2785893 | 88989 | None | code180 | Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898 - 5 - 32 Amp DP | Nos | 1103.0 | 1103.0 | 2.0 | False | None | None | False | None | False | 2206.0 | 0 |
2785894 | 88989 | None | code181 | Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898 - 5 - 32 A TPN | Nos | 1777.0 | 1777.0 | 2.0 | False | None | None | False | None | False | 3554.0 | 0 |
2785895 | 88989 | None | code182 | Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898 - 40 - 63 Amp TPN | Nos | 2399.0 | 2399.0 | 1.0 | False | None | None | False | None | False | 2399.0 | 0 |
2785896 | 88989 | None | code183 | Supplying exhaust fan 0f 1440 RPM of300 mm (12") size with bracket blades complte for light duty suitable to operate on 230V 50 Hz AC Supply -Make Fans : Crompton / Usha / Anchor | Each | 1542.0 | 1542.0 | 15.0 | False | None | None | False | None | False | 23130.0 | 0 |
2785897 | 88989 | None | code184 | Supplying capacitor type ceiling Fan complete with down rod blades shackle ,canopies etc. for operation on 230 Vots 50 cycles ,single phase AC supply confirming to ISS -374-1979 with double ball bearing system 48 " Sweep Economy model | Each | 2085.0 | 2085.0 | 10.0 | False | None | None | False | None | False | 20850.0 | 0 |