| 2762005 | 87959 | None | P.No.187, I.No.19.3 Volume-2 PWD SR 2023-24 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. | Cum | 2498.78 | 2498.78 | 20.81 | False | None | None | False | None | False | 51999.6118 | 0 |
| 2762006 | 87959 | None | P.No.187 I. No.19.8.3 (ii) Volume-2 PWDSR-2023-24 | Removing mortar from bricks and cleaning bricks including stacking to the appropriate disposal area as per direction of Engineer-in-charge. (stacks of cleaned bricks shall be measured): From brick work in cement mortar | Cum | 4645.3 | 4645.3 | 23.0 | False | None | None | False | None | False | 106841.9 | 0 |
| 2762007 | 87959 | None | P.No.187 I. No.19.9.2 Volume-2 PWD SR-2023-24 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer- in-charge. In cement mortar | Cum | 1734.52 | 1734.52 | 17.89 | False | None | None | False | None | False | 31030.5628 | 0 |
| 2762008 | 87959 | None | P.No.36 I. No.1.12 Volume-1 PWDSR-2023-24 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including Cost of labour, tools, usage of machinery & other appurtenances required to complete the work. A) MAChINERY Hydraulic Excavator 1.1m capacity | Cum | 1596.5 | 1596.5 | 54.0 | False | None | None | False | None | False | 86211.0 | 0 |
| 2762009 | 87959 | None | P.No.8 I.No.1.14.1 Volume-1 PWD-2023-24 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work In all kinds of soils Depth upto 3 m | Cum | 105.06 | 105.06 | 153.81 | False | None | None | False | None | False | 16159.2786 | 0 |
| 2762010 | 87959 | None | P.No.58 I.No.2.1.3 Volume-1 PWD SR 2023-24 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm and down size graded crushed coarse aggregates | Cum | 6168.67 | 6168.67 | 20.3 | False | None | None | False | None | False | 125224.001 | 0 |
| 2762011 | 87959 | None | P.No.62 I.No.2.2.1 Volume-1 PWD SR 2023-24 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in inished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6789.96 | 6789.96 | 28.07 | False | None | None | False | None | False | 190594.1772 | 0 |
| 2762012 | 87959 | None | P.No.9 I.No.5.3 Volume-2 PWD SR 2023-24 | Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6391.15 | 6391.15 | 76.21 | False | None | None | False | None | False | 487069.5415 | 0 |
| 2762013 | 87959 | None | P.No.9 I.No.5.4 Volume-2 PWD SR 2023-24 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6580.67 | 6580.67 | 26.73 | False | None | None | False | None | False | 175901.3091 | 0 |
| 2762014 | 87959 | None | P.No.15 I.No.2.3.1 Volume-1 PWD SR 2023-24 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Column | Cum | 10938.79 | 10938.79 | 1.5 | False | None | None | False | None | False | 16408.185 | 0 |
| 2762015 | 87959 | None | P.No.15 I.No.2.3.1 Volume-1 PWD SR 2023-24 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Plinth Beam | Cum | 9674.19 | 9674.19 | 7.21 | False | None | None | False | None | False | 69750.9099 | 0 |
| 2762016 | 87959 | None | P.No.7 I.No.1.9 Volume-1 PWD SR-2023-24 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 273.98 | 273.98 | 153.81 | False | None | None | False | None | False | 42140.8638 | 0 |
| 2762017 | 87959 | None | P.NO.18.I.NO.2.11 PWD SR 2023-24 Volume-1 | Steel Fabrication
Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification a) Buildings | Tonne | 92140.71 | 92140.71 | 2.418 | False | None | None | False | None | False | 222796.23678 | 0 |
| 2762018 | 87959 | None | P.No.13 I.No.6.4 Volume-2 PWD SR-2023-24 | Super Structure:Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement: 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer in charge of work.
| Cum | 8920.83 | 8920.83 | 49.76 | False | None | None | False | None | False | 443900.5008 | 0 |
| 2762019 | 87959 | None | P.No.15, I.No.2.1.4 Volume-1 PWD SR 2023-24 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6403.51 | 6403.51 | 1.98 | False | None | None | False | None | False | 12678.9498 | 0 |
| 2762020 | 87959 | None | P.No.15, I.No.2.1.4 Volume-1 PWD SR 2023-24 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11469.9 | 11469.9 | 8.98 | False | None | None | False | None | False | 102999.702 | 0 |
| 2762021 | 87959 | None | P.No.15, I.No.2.1.4 Volume-1 PWD SR 2023-24 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10806.9 | 10806.9 | 13.17 | False | None | None | False | None | False | 142326.873 | 0 |
| 2762022 | 87959 | None | P.No.78 I.No.2.5.1 Volume-1 PWD SR-2023-24 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates | Cum | 10143.9 | 10143.9 | 38.17 | False | None | None | False | None | False | 387192.663 | 0 |
| 2762023 | 87959 | None | P.No.78 I.No.2.5.1 Volume-1 PWD SR-2023-24 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates | Cum | 9812.4 | 9812.4 | 0.43 | False | None | None | False | None | False | 4219.332 | 0 |
| 2762024 | 87959 | None | P.NO.18.I.NO.2.11 PWD SR 2023-24 Volume-1 | Steel Fabrication
Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification a) Buildings | Tonne | 92140.71 | 92140.71 | 5.083 | False | None | None | False | None | False | 468351.22893 | 0 |
| 2762025 | 87959 | None | P.No.61 I.No.9.17.2 Volume-2 PWD SR-2023-24 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm | Sqm | 1210.25 | 1210.25 | 208.57 | False | None | None | False | None | False | 252421.8425 | 0 |
| 2762026 | 87959 | None | P.No.77 I.No.11.5.1 Volume-2 PWD SR-2023-24 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Sqm | 4612.34 | 4612.34 | 23.04 | False | None | None | False | None | False | 106268.3136 | 0 |
| 2762027 | 87959 | None | P.No.86, I.No.11.34 B Volume-2 PWD SR 2023-24 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. | Sqm | 173.04 | 173.04 | 23.04 | False | None | None | False | None | False | 3986.8416 | 0 |
| 2762028 | 87959 | None | P.No.41 I.No.8.3.1Volume-2 PWD-2023-24 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 364.62 | 364.62 | 284.59 | False | None | None | False | None | False | 103767.2058 | 0 |
| 2762029 | 87959 | None | P.No.41 I.No.8.5.2 Volume-2 PWD SR-2023-24 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement:4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 359.47 | 359.47 | 286.27 | False | None | None | False | None | False | 102905.4769 | 0 |
| 2762030 | 87959 | None | P.No.48 I.No.8.40 Volume-02 PWD SR-2023-24 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 118.45 | 118.45 | 55.89 | False | None | None | False | None | False | 6620.1705 | 0 |
| 2762031 | 87959 | None | P.No.125 I. No. 13.50.8 Volume-1 PWDSR-2023-24 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 80 mm nominal dia Pipes | Sqm | 694.22 | 694.22 | 16.0 | False | None | None | False | None | False | 11107.52 | 0 |
| 2762032 | 87959 | None | P.No.45 I. No.8.28 Volume-2 PWD SR 2023-24 | Finishing walls with water proofing cement paint of required shade : New work (Two coats applied @ 4.84kg/10m2) to give an even shade after thoroughly booming the surface to remove all dirt, dust, mortar drops and foreign matter including preper smooth, cost of materials, labour complete as per specification and as per directions of Engineer-in-charge. | Sqm | 91.67 | 91.67 | 335.44 | False | None | None | False | None | False | 30749.7848 | 0 |
| 2762033 | 87959 | None | It No.8.25 Page No-45 Volume-02 PWD SR-2023-24 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and in-cluding water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 141.11 | 141.11 | 503.0 | False | None | None | False | None | False | 70978.33 | 0 |
| 2762034 | 87959 | None | P.No.NO149 I.No.15.1 Volume-2 PWD SR 2023-24 | Polyurethane based Single Component for New Surface
Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. | Sqm | 841.51 | 841.51 | 218.5 | False | None | None | False | None | False | 183869.935 | 0 |
| 2762035 | 87959 | None | P.No.41 I.No.8.3.1Volume-2 PWD-2023-24 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 364.62 | 364.62 | 50.13 | False | None | None | False | None | False | 18278.4006 | 0 |
| 2762036 | 87959 | None | P.No.2 I. No. 1.1.2 Volume-6 Electrical SR 2023-24 | ELECTRIFICATION: Open Conduit System
Supplying heavy gauge PVC conduit pipe 25mm dia 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. | Mtr | 81.0 | 81.0 | 120.0 | False | None | None | False | None | False | 9720.0 | 0 |
| 2762037 | 87959 | None | P.No.2 I. No.1.5.1 Volume-6 Electrical SR 2023-24 | Supplying and fixing PVC/ metal conduit Deep junction box 19/20 mm deep Junction box | Each | 49.0 | 49.0 | 30.0 | False | None | None | False | None | False | 1470.0 | 0 |
| 2762038 | 87959 | None | P.No.6 I. No.2.1.3 Volume-6 Electrical SR 2023-24 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694 and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Long point above 6Mtr upto 10Mtr from tapping point to out let via switch | Each | 570.0 | 570.0 | 6.0 | False | None | None | False | None | False | 3420.0 | 0 |
| 2762039 | 87959 | None | P.No.9 I. No.3.6.9 Volume-6 Electrical SR 2023-24 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6A Three Way socket | Each | 171.0 | 171.0 | 6.0 | False | None | None | False | None | False | 1026.0 | 0 |
| 2762040 | 87959 | None | P.No.9 I. No.3.6.9 Volume-6 Electrical SR 2023-24 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 32A DP Switch | Each | 326.0 | 326.0 | 6.0 | False | None | None | False | None | False | 1956.0 | 0 |
| 2762041 | 87959 | None | P.No.9 I. No.3.8 Volume-6 Electrical SR 2023-24 | Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screws. | Sqm | 0.41 | 0.41 | 2400.0 | False | None | None | False | None | False | 984.0 | 0 |
| 2762042 | 87959 | None | P.No.17 I.No.5.19.5 Volume-6 Electrical SR 2023-24 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure 16 Way SP & N | Each | 2932.0 | 2932.0 | 2.0 | False | None | None | False | None | False | 5864.0 | 0 |
| 2762043 | 87959 | None | P.No.18 I. No.5.20.4Volume-6 Electrical SR 2023-24 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board.32-40A 2 pole | Each | 4559.0 | 4559.0 | 2.0 | False | None | None | False | None | False | 9118.0 | 0 |
| 2762044 | 87959 | None | P.No.47 I.No.11.11.7Volume-6 Electrical SR 2023-24 | Supplying & fixing of retrofit type - LED bulb . W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition 18W, 6500K | Each | 426.0 | 426.0 | 16.0 | False | None | None | False | None | False | 6816.0 | 0 |
| 2762045 | 87959 | None | P.No.5 I. No.2.3.1 Volume-6 Electrical SR 2023-24 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 1 mm2 | Mtr | 19.0 | 19.0 | 100.0 | False | None | None | False | None | False | 1900.0 | 0 |
| 2762046 | 87959 | None | P.No.13 I. No.6.3.2 Volume-6 Electrical SR 2023-24 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system | Each | 3031.0 | 3031.0 | 6.0 | False | None | None | False | None | False | 18186.0 | 0 |
| 2762047 | 87959 | None | P.No.5 I. No.2.3.3 Volume-6 Electrical SR 2023-24 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 2.5 mm | Mtr | 42.0 | 42.0 | 50.0 | False | None | None | False | None | False | 2100.0 | 0 |
| 2762048 | 87959 | None | P.No.17 I.No.5.18.3 Volume-6 Electrical SR 2023-24 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63 A SP | Each | 811.0 | 811.0 | 2.0 | False | None | None | False | None | False | 1622.0 | 0 |
| 2762049 | 87959 | None | P.No.18 I.No.5.19.4 Volume-6 Electrical SR 2023-24 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3
phase/single door with powder coated painting Made out of 14 SWG MS enclosure.12 Way SP & N | Each | 1863.0 | 1863.0 | 1.0 | False | None | None | False | None | False | 1863.0 | 0 |
| 2762050 | 87959 | None | P.No.5 I. No.2.1.1 Volume-6 Electrical SR 2023-24 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with
a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch | Mtr | 285.0 | 285.0 | 40.0 | False | None | None | False | None | False | 11400.0 | 0 |
| 2762051 | 87959 | None | P.No.8 I. No.3.4.5 Volume-6 Electrical SR 2023-24 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way | Each | 261.0 | 261.0 | 15.0 | False | None | None | False | None | False | 3915.0 | 0 |
| 2762052 | 87959 | None | P.No.2 I. No.1.4.7 Volume-6 Electrical SR 2023-24 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 200 x 200 x 65 mm | Each | 348.0 | 348.0 | 6.0 | False | None | None | False | None | False | 2088.0 | 0 |