tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1708578511000 | 1 | None | None | Terminal Bay | Tender for Combined package of Balance portion of work for a) Balance work of 110/11kV Substation of Karaya in Belthangady Taluk | 3283678.5 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2747987 | 87412 | None | Code001 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other oppurtenances required to complete the work. In all kinds of soils upto 300 mm depth (Including Road levelling) | Cum | 125.55 | 125.55 | 571.5 | False | None | None | False | None | False | 71751.825 | 0 | 2747988 | 87412 | None | Code002 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 134.8 | 134.8 | 87.18 | False | None | None | False | None | False | 11751.864 | 0 | 2747989 | 87412 | None | Code003 | Construction of dry lean cement concrete Sub- base over aprepared sub-grade with coarse and fine aggregate conformingto IS: 383, the size of coarse aggregate not exceeding 25 mm,aggregate cement ratio not to exceed 14:1, aggregate gradation after blending to be as per table 600-1, cement content not to beless than 140 kg/ m3 , optimum moisture content to be determined during trial length construction, concrete strength not to be less than 7 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing. Dry Lean Cement Concrete Sub-base | Cum | 6502.27 | 6502.27 | 37.5 | False | None | None | False | None | False | 243835.125 | 0 | 2747990 | 87412 | None | Code004 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M 40 Design Mix Using 20 mm nominal size graded crushed coarse aggregates M40 OPC at 420 kg/m3 For Road add at 5% formwork | Cum | 10438.13 | 10438.13 | 67.28 | False | None | None | False | None | False | 702277.3864 | 0 | 2747991 | 87412 | None | Code005 | Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification All other type of structures | Kg | 104.42 | 104.42 | 1826.08 | False | None | None | False | None | False | 190679.2736 | 0 | 2747992 | 87412 | None | Code006 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc . complete for: PVC pipes 160mm dia., 10 Kg/m2 | m | 1280.63 | 1280.63 | 30.5 | False | None | None | False | None | False | 39059.215 | 0 | 2747993 | 87412 | None | Code007 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired densit Wet Mix Macadam (Plant Mix Method) | Cum | 3381.97 | 3381.97 | 61.88 | False | None | None | False | None | False | 209276.3036 | 0 | 2747994 | 87412 | None | Code008 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 90mm dia., 6 kg/sqcm & class 3 | m | 388.55 | 388.55 | 90.0 | False | None | None | False | None | False | 34969.5 | 0 | 2747995 | 87412 | None | Code009 | Jelly Spreading (20-25 mm) : Supplying and providing jelly in the station yard of uniform thickness of 100 mm including the cost of materials, labour charges, required tools and plants etc., complete. Work shall be carried out as per the instructions of Engineer in-charge of works as per the standard procedure. | Cum | 2343.2 | 2343.2 | 537.96 | False | None | None | False | None | False | 1260547.872 | 0 | 2747996 | 87412 | None | Code010 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7485.54 | 7485.54 | 10.97 | False | None | None | False | None | False | 82116.3738 | 0 | 2747997 | 87412 | None | Code011 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 8443.7 | 8443.7 | 7.43 | False | None | None | False | None | False | 62736.691 | 0 | 2747998 | 87412 | None | Code012 | Providing Flush/ Ruled pointing Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lin ing, including cost of materials, labour, curing as per specifications and as per directions of Engineer- | Sqm | 337.01 | 337.01 | 102.5 | False | None | None | False | None | False | 34543.525 | 0 | 2747999 | 87412 | None | Code013 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, form work, centering & scaffolding and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregate for DPC sill coping & screed concrete add at 5% | Cum | 8627.21 | 8627.21 | 10.99 | False | None | None | False | None | False | 94813.0379 | 0 | 2748000 | 87412 | None | Code014 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 206.17 | 206.17 | 369.0 | False | None | None | False | None | False | 76076.73 | 0 | 2748001 | 87412 | None | Code015 | Providing and applying painting in two coats with Acid proof paint of approved brand on wall surface to give an even shade after throughly brushing the surface free from mortar drops and other foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour, complete as per specifications with primer to the battery Room. | Sqm | 251.1 | 251.1 | 36.0 | False | None | None | False | None | False | 9039.6 | 0 | 2748002 | 87412 | None | Code016 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 151.98 | 151.98 | 23.0 | False | None | None | False | None | False | 3495.54 | 0 | 2748003 | 87412 | None | Code017 | Earth mat formation: Supplying, Laying and welding of M.S.Flats 50 x 6 mm, applying ACB paint to welded portion and covering with sodium bentonite Clay. wherever required. | m | 533.93 | 533.93 | 200.0 | False | None | None | False | None | False | 106786.0 | 0 | 2748004 | 87412 | None | Code018 | Supplying and Grounding of Equipment with G.I.Flat 50x6mm and connecting Equipment to the earth mat/ground pit. Each point of earthing with all formation works like bending, twisting, drilling of holes and connecting by welding (inclusive of T&P and consumables) to the earthmat/Groundpit/point of earth connection. | m | 442.74 | 442.74 | 67.81 | False | None | None | False | None | False | 30022.1994 | 0 | 2748005 | 87412 | None | Code019 | Balance work to be executed in Water Supply System: Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 g/L as per specifications and as per directions of Engineer in charge Wall painting with plastic emulsion paintof approved brand and manufacture to give an even shade: One coats on old work as per specifications and as per directions of Engineer in charge: RCC over head tank platform-Columns, slabs | Sqm | 178.42 | 178.42 | 20.25 | False | None | None | False | None | False | 3613.005 | 0 | 2748006 | 87412 | None | Code020 | Balance work to be executed Baffle Wall/Fire Wall Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 206.17 | 206.17 | 79.0 | False | None | None | False | None | False | 16287.43 | 0 |
| 1708578511000 | 1 | None | None | Terminal Bay | Tender for Combined package of Balance portion of work for b)Balance work of Construction of proposed 110kV SC line in DC towers from Puttur VIT college limits to Karaya substation for a distance of 15kms | 5121827.08 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2748007 | 87413 | None | Code001 | Supply of Bolts, Nuts and washers etc., galvanised) required for 110kV DC Transmission Line Towers Normal Tower Type B | Kg | 188.7 | 188.7 | 1176.7 | False | None | None | False | None | False | 222043.29 | 0 | 2748008 | 87413 | None | Code002 | Supply of Bolts, Nuts and washers etc., galvanised) required for 110kV DC Transmission Line Towers 3M Extension to B Type Tower | Kg | 188.7 | 188.7 | 40.2 | False | None | None | False | None | False | 7585.74 | 0 | 2748009 | 87413 | None | Code003 | Supply of Bolts, Nuts and washers etc., (galvanised) required for 110kV DC Transmission Line Towers 6M Extension to B Type Tower | Kg | 188.7 | 188.7 | 21.4 | False | None | None | False | None | False | 4038.18 | 0 | 2748010 | 87413 | None | Code004 | Supply of Bolts, Nuts and washers etc., (galvanised) required for 110kV DC Transmission Line Towers Normal Tower Type C | Kg | 188.7 | 188.7 | 1260.75 | False | None | None | False | None | False | 237903.525 | 0 | 2748011 | 87413 | None | Code005 | Supply of Bolts, Nuts and washers etc., (galvanised) required for 110kV DC Transmission Line Towers +3M Extension to C Type Tower | Kg | 188.7 | 188.7 | 26.8 | False | None | None | False | None | False | 5057.16 | 0 | 2748012 | 87413 | None | Code006 | Supply of Bolts, Nuts and washers etc., (galvanised) required for 110kV DC Transmission Line Towers 6M Extension to C Type Tower | Kg | 188.7 | 188.7 | 85.6 | False | None | None | False | None | False | 16152.72 | 0 | 2748013 | 87413 | None | Code007 | De-Riveting of Bolts and Nuts and Re welding of newly replaced bolts and Nuts Normal Tower Type B | No | 58.15 | 58.15 | 3500.0 | False | None | None | False | None | False | 203525.0 | 0 | 2748014 | 87413 | None | Code008 | De-Riveting of Bolts and Nuts and Re welding of newly replaced bolts and Nuts 3M Extension to B Type Tower | No | 58.15 | 58.15 | 150.0 | False | None | None | False | None | False | 8722.5 | 0 | 2748015 | 87413 | None | Code009 | De-Riveting of Bolts and Nuts and Re welding of newly replaced bolts and Nuts 6M Extension to B Type Tower | No | 58.15 | 58.15 | 70.0 | False | None | None | False | None | False | 4070.5 | 0 | 2748016 | 87413 | None | Code010 | De-Riveting of Bolts and Nuts and Re welding of newly replaced bolts and Nuts Normal Tower Type C | No | 58.15 | 58.15 | 3750.0 | False | None | None | False | None | False | 218062.5 | 0 | 2748017 | 87413 | None | Code011 | De-Riveting of Bolts and Nuts and Re welding of newly replaced bolts and Nuts 3M Extension to C Type Tower | No | 58.15 | 58.15 | 100.0 | False | None | None | False | None | False | 5815.0 | 0 | 2748018 | 87413 | None | Code012 | De-Riveting of Bolts and Nuts and Re welding of newly replaced bolts and Nuts 6M Extension to C Type Tower | No | 58.15 | 58.15 | 280.0 | False | None | None | False | None | False | 16282.0 | 0 | 2748019 | 87413 | None | Code013 | Anticlimbing Device/Barbed wire Supplying and fixing G.I. Angle iron 45 x 45 x 5 mm (1 m length) with cleats, bolt & nuts as per specification and fixing above 0.5 m length each at inner and outer surface of the tower to facilitate running of barbed wire | No | 5446.31 | 5446.31 | 15.0 | False | None | None | False | None | False | 81694.65 | 0 | 2748020 | 87413 | None | Code014 | Anticlimbing Device/Barbed wire Supplying and fixing Barbed wire - For 110kV DC Towers- 69 tower Locations. ( 150 mtr/tower) 150x69= 10350 mtr and for For 220kV DC Towers- 7 Tower Locations. 250mtr/tower =250x7= 1750 mtr. Total 76 Locations= 10350+1750= 12100 mtr | Rmtr | 100.44 | 100.44 | 12100.0 | False | None | None | False | None | False | 1215324.0 | 0 | 2748021 | 87413 | None | Code015 | BENCHING Earth work excavation for leveling and lowering the ground and removing the excavated earth to the places directed with all leads and lifts , spreading and leveling etc complete wherever necessary all types of soil | Cum | 125.55 | 125.55 | 177.09 | False | None | None | False | None | False | 22233.6495 | 0 | 2748022 | 87413 | None | Code016 | Revetment/Retaining wall: Design, Engineering and Construction of Revetment/Retaining wall with the following items of the work as per drawing, specifications and directions of the Engineer incharge of the work. a) Earth work excavation for foundation with all leads and lifts etc complete as per specifications, drawings and directions of the Engineer incharge of the work. For all types of soil | Cum | 134.8 | 134.8 | 217.1 | False | None | None | False | None | False | 29265.08 | 0 | 2748023 | 87413 | None | Code017 | Revetment/Retaining wall: b) Providing and laying granite or basalt or trap jelly concrete using 40mm and down size jelly for foundation laid in 15cms thick layers and well compacted including curing etc., complete cement concrete 1:4:8 | Cum | 7485.54 | 7485.54 | 32.87 | False | None | None | False | None | False | 246049.6998 | 0 | 2748024 | 87413 | None | Code018 | Revetment/Retaining wall: (c) Providing and constructing granite or trap or basalt Rubble stone masonry with bond stones at 2m apart (uncoursed) including curing etc., complete for foundation and super structure as per specifications, drawings and directions of engineer incharge of the work in cement mortar 1:6. | Cum | 7415.5 | 7415.5 | 337.31 | False | None | None | False | None | False | 2501322.305 | 0 | 2748025 | 87413 | None | Code019 | Revetment/Retaining wall d) Providing Plain Cement concrete 1:2:4 Coping Supply of all labour, materials, tools & plants etc., and providing concrete using 20mm & down size jelly and clean approved sand, machine mixed, concrete laid in layers not exceeding 150mm thick, vibrated, for foundation of all type transmission line towers other items not mentioned here in but required for completion of works as per detailed specification, drawing and directions of engineer incharge of works | Cum | 8463.53 | 8463.53 | 9.06 | False | None | None | False | None | False | 76679.5818 | 0 |
| 1708578511000 | 0 | None | None | Terminal Bay | Tender for Combined package of Balance portion of work for c) Balance work of Construction of 110kV terminal bay for the proposed 110kV SC line to Karaya at existing 110kV Puttur substation in Dakshina Kannada district. | 5476151.1 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2748026 | 87414 | None | code001 | Supply of SF6 Gas circuit breaker with Semi-Pneumatic Pneumatic operated / Spring type operating mechanism, including mounting arrangements with rigid bi-metallic terminal connector complete suitable for Drake ACSR conductor and mounting structures.A) 110kV 1250Amps 31.5KA | No | 929098.02 | 929098.02 | 1.0 | False | None | None | False | None | False | 929098.02 | 0 | 2748027 | 87414 | None | code002 | Supply of Isolators : Isolators including marshalling box and suitable terminal connectors, as required as per technical specification with solid core cylindrical post insulators:A) 110KV, 1250A, 31.5KA Class Double Break Manually operated isolator With terminal connectors suitable for Drake ACSR.Upright mounting type with earth switch with live point height 4600mm | No | 519719.2 | 519719.2 | 1.0 | False | None | None | False | None | False | 519719.2 | 0 | 2748028 | 87414 | None | code003 | Supply of Isolators : Isolators including marshalling box and suitable terminal connectors, as required as per technical specification with solid core cylindrical post insulators:A) 110KV, 1250A, 31.5KA Class Double Break Manually operated isolator With terminal connectors suitable for Drake ACSR.Upright mounting type without earth switch with live point height 6350 mm | No | 452555.49 | 452555.49 | 1.0 | False | None | None | False | None | False | 452555.49 | 0 | 2748029 | 87414 | None | code004 | Supply of Current Transformer: Current Transformer including Marshalling box, Single phase, oil filled outdoor type with rigid bimetallic terminal connectors suitable for Drake ACSR 1) 110 KV Class, 31.5 KA, CT of ratio 400-200/1-1-1A for Lines For metering: Accuracy 0.2, Burden 10VA For back up protection: Accuracy 5P20, Burden 30VA For differential/ distance protection: PS class | No | 179103.23 | 179103.23 | 3.0 | False | None | None | False | None | False | 537309.69 | 0 | 2748030 | 87414 | None | code005 | Supply of Lightning Arrestor : Surge arrestors (Porcelain housing) Metal Oxide Gap less type as per technical specification with suitable rigid bi-metallic terminal connectors suitable for Drake ACSR.96 KV, 10 KA, Class - II | No | 54370.62 | 54370.62 | 3.0 | False | None | None | False | None | False | 163111.86 | 0 | 2748031 | 87414 | None | code006 | b) Supply of Numerical distance relay for 110KV system compatible to IEC 61850 communication protocol. | No | 313907.75 | 313907.75 | 1.0 | False | None | None | False | None | False | 313907.75 | 0 | 2748032 | 87414 | None | code007 | c) Supply of Master trip relay | No | 22341.65 | 22341.65 | 1.0 | False | None | None | False | None | False | 22341.65 | 0 | 2748033 | 87414 | None | code008 | Supply of Station Structures : 110kV Side station structure fabricated out of galvanized mild steel including Bolts and Nuts (Approx. Unit Wt. in MT add 5% towards B & N) Station beams (1B1) | Kg | 179.1 | 179.1 | 553.0 | False | None | None | False | None | False | 99042.3 | 0 | 2748034 | 87414 | None | code009 | Supply of GI Mounting structure including Bolts & Nuts (Lattice type) (For 110KV Sub-Station) - (Approx. Unit Wt. in MT add 5% towards B & N)
110KV Isolators Live Point Height 4600mm | Kg | 179.1 | 179.1 | 752.0 | False | None | None | False | None | False | 134683.2 | 0 | 2748035 | 87414 | None | code010 | Supply of GI Mounting structure including Bolts & Nuts (Lattice type) (For 110KV Sub-Station) - (Approx. Unit Wt. in MT add 5% towards B & N)
110KV Isolators Live Point Height 6350mm | Kg | 179.1 | 179.1 | 982.0 | False | None | None | False | None | False | 175876.2 | 0 | 2748036 | 87414 | None | code011 | BUS BAR FORMATION:Supply of Drake ACSR | m | 511.46 | 511.46 | 75.0 | False | None | None | False | None | False | 38359.5 | 0 | 2748037 | 87414 | None | code012 | Supply of Insulators : Single Suspension string using 9 Units of each 11kV, 90KN Disc Insulator along with Suspension Clamp and hardware suitable for Drake ACSR. (110kV side) | No | 12167.97 | 12167.97 | 3.0 | False | None | None | False | None | False | 36503.91 | 0 | 2748038 | 87414 | None | code013 | Supply of Hardwares : LYNX to Drake - Wedge Connector Type | No | 2538.79 | 2538.79 | 3.0 | False | None | None | False | None | False | 7616.37 | 0 | 2748039 | 87414 | None | code014 | supply of Copper Control Cables : 1.1kV PVC insulated Copper Control Cable with Lugs/Ferrules as per technical specifications.
19 C x 2.5 Sqmm | m | 693.84 | 693.84 | 200.0 | False | None | None | False | None | False | 138768.0 | 0 | 2748040 | 87414 | None | code015 | supply of Copper Control Cables : 1.1kV PVC insulated Copper Control Cable with Lugs/Ferrules as per technical specifications.
4 C x 6.0 Sqmm | m | 326.44 | 326.44 | 850.0 | False | None | None | False | None | False | 277474.0 | 0 | 2748041 | 87414 | None | code016 | RIGID BUS BAR FORMATION:Supply of Rigid Bus with Taps & Clamps : Aluminium pipe conforming to 6340 WP of IS - 5082 / 1969 (BS I6000-Sch. 40) of following nominal diameter 63 mm size connecting isolator to vertical tap 110KV side | m | 1918.96 | 1918.96 | 25.0 | False | None | None | False | None | False | 47974.0 | 0 | 2748042 | 87414 | None | code017 | Supply of TAPS: Inverted V tap made of 63mm Aluminum tube of 2500mm for vetical portion and cross bus with rounded off end | No | 6014.6 | 6014.6 | 3.0 | False | None | None | False | None | False | 18043.8 | 0 | 2748043 | 87414 | None | code018 | Supply of Expansion type terminal connector suitable for 63mm Aluminium pipe | No | 6539.28 | 6539.28 | 3.0 | False | None | None | False | None | False | 19617.84 | 0 | 2748044 | 87414 | None | code019 | supply of Copper Control Cables :1.1kV PVC insulated Copper Control Cable with Lugs/Ferrules as per technical specifications.
4 C x 2.5 Sqmm | m | 187.67 | 187.67 | 350.0 | False | None | None | False | None | False | 65684.5 | 0 | 2748045 | 87414 | None | code020 | SUPPLY OF ACSR Conductor from Tower Loc No 18 to Station Guantry ACSR LYNX Conductor | m | 253.75 | 253.75 | 300.0 | False | None | None | False | None | False | 76125.0 | 0 | 2748046 | 87414 | None | code021 | Supply of INSULATOR STRINGS WITH CLAMPS, ARCING HORNS AND HARDWARE for ACSR Lynx Conductor single Tension String fittings using 1X8 Nos. 90KN Disc Insulators, Clamps, Arcing Horns and Hardwares (Set) for termination of line to bay | No | 10305.84 | 10305.84 | 12.0 | False | None | None | False | None | False | 123670.08 | 0 | 2748047 | 87414 | None | code022 | Supply of Accessories for ACSR Lynx conductor:C Type wedge clamp for LYNX to LYNX | No | 1811.91 | 1811.91 | 12.0 | False | None | None | False | None | False | 21742.92 | 0 | 2748048 | 87414 | None | code023 | Supply of Accessories for ACSR Lynx conductor:Vibration dampers | No | 1340.1 | 1340.1 | 6.0 | False | None | None | False | None | False | 8040.6 | 0 | 2748049 | 87414 | None | code024 | Supply of Accessories for ACSR Lynx conductor:MSC Joints for LYNX ACSR | No | 882.83 | 882.83 | 3.0 | False | None | None | False | None | False | 2648.49 | 0 | 2748050 | 87414 | None | code025 | Supply of Hardware & Accessories for Ground Wire:Tension clamps | No | 1630.85 | 1630.85 | 2.0 | False | None | None | False | None | False | 3261.7 | 0 | 2748051 | 87414 | None | code026 | YARD LIGHTS:a) Supply of Station yard lighting (outdoor type) fabricated Galvainsed Lattice structure type- 0.191MT per sturcture, (for 1No of lights) 1 x 0.191 MT | Kg | 179.1 | 179.1 | 191.0 | False | None | None | False | None | False | 34208.1 | 0 | 2748052 | 87414 | None | code027 | YARD LIGHTS:b) Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70 percent, maximum light intensity should be between 60 degrees to 70 degrees. CCT grteater that 5500K IP 66 optical and electrical compartment and impact resistance of complete luminaire IK08. Power Factor less than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 and LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with 150W System Power consumption. LED Efficiency greater than 130lm / w nominal CRIgreater than 75 Luminaire manufacturer should have in-house facility accredited by NABL / CPRI and any Government certified agency and Design and Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer and Cree/Nichia/Lumileds/Osram make LED Source | No | 19434.13 | 19434.13 | 1.0 | False | None | None | False | None | False | 19434.13 | 0 | 2748053 | 87414 | None | code028 | YARD LIGHTS:c)Supplying and drawing Flexible Multicore cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and PVC insulation sheathed suitable for working voltage upto 1100 volts as per IS-694:1990 3CX1.5mm square cable | m | 95.16 | 95.16 | 25.0 | False | None | None | False | None | False | 2379.0 | 0 | 2748054 | 87414 | None | code029 | YARD LIGHTS:d)Supplying and fixing regular MCB distribution boards on wall/ood board/ flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. I-Single Door- 4 Way SP&N | No | 1640.11 | 1640.11 | 1.0 | False | None | None | False | None | False | 1640.11 | 0 | 2748055 | 87414 | None | code030 | YARD LIGHTS:e)Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials an 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32A SP | No | 548.46 | 548.46 | 1.0 | False | None | None | False | None | False | 548.46 | 0 | 2748056 | 87414 | None | code031 | YARD LIGHTS:f)Supplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 19/20mm dia 2mm thick | m | 91.19 | 91.19 | 18.0 | False | None | None | False | None | False | 1641.42 | 0 | 2748057 | 87414 | None | code032 | Material for new bay integration to existing SCADA panel:Supply of Multi Functional Transducer(MFT) 0.2S Class | No | 6442.8 | 6442.8 | 1.0 | False | None | None | False | None | False | 6442.8 | 0 | 2748058 | 87414 | None | code033 | Material for new bay integration to existing SCADA panel:Supply of Opto Coupler(220 or 110V DC) | No | 1733.94 | 1733.94 | 1.0 | False | None | None | False | None | False | 1733.94 | 0 | 2748059 | 87414 | None | code034 | Material for new bay integration to existing SCADA panel:Supply of Current Cable- Copper core with 4.0sqmm cross section multistrand 7 Core for CT Termination | m | 371.37 | 371.37 | 5.0 | False | None | None | False | None | False | 1856.85 | 0 | 2748060 | 87414 | None | code035 | Material for new bay integration to existing SCADA panel:Supply of Voltgae cables- Copper core with 2.5 sqmm cross section multistrand 4 core for PT Termination | m | 187.67 | 187.67 | 5.0 | False | None | None | False | None | False | 938.35 | 0 | 2748061 | 87414 | None | code036 | Material for new bay integration to existing SCADA panel:Supply of signal/Communication Cables- Armoured copper Core with 0.5sqmm cross section multistrand 10core | m | 188.99 | 188.99 | 15.0 | False | None | None | False | None | False | 2834.85 | 0 | 2748062 | 87414 | None | code037 | Material for new bay integration to existing SCADA panel:Supply of Control Cables-armoured copper core with 1.5sqmm cross section multistrand 10core | m | 204.85 | 204.85 | 15.0 | False | None | None | False | None | False | 3072.75 | 0 | 2748063 | 87414 | None | code038 | Material for new bay integration to existing SCADA panel:Supply of Digital Input Card | No | 49863.97 | 49863.97 | 1.0 | False | None | None | False | None | False | 49863.97 | 0 | 2748064 | 87414 | None | code039 | Material for new bay integration to existing SCADA panel:Supply of Digital Output Card | No | 49863.97 | 49863.97 | 1.0 | False | None | None | False | None | False | 49863.97 | 0 | 2748065 | 87414 | None | code040 | Material for new bay integration to existing SCADA panel:Supply of Heavy Duty Relays | No | 777.1 | 777.1 | 2.0 | False | None | None | False | None | False | 1554.2 | 0 | 2748066 | 87414 | None | code041 | Material for new bay integration to existing SCADA panel:Supply of Data Concentrator Unit | No | 49573.22 | 49573.22 | 1.0 | False | None | None | False | None | False | 49573.22 | 0 | 2748067 | 87414 | None | code042 | Erection of Circuit Breaker :SF6 Gas circuit breaker with Semi-Pneumatic / Pneumatic operated / Spring type operating mechanism, including mounting arrangements, rigid bi-metallic terminal connector complete suitable for Drake ACSR conductor and mounting structures.110kV, 1250A, 31.5KA Class | No | 14293.1 | 14293.1 | 1.0 | False | None | None | False | None | False | 14293.1 | 0 | 2748068 | 87414 | None | code043 | Wiring of Circuit breaker:Identification, ferruling, crimping and termination of wires in Breaker & Wiring up to control panel/Relay panels | No | 11216.42 | 11216.42 | 1.0 | False | None | None | False | None | False | 11216.42 | 0 | 2748069 | 87414 | None | code044 | Erection of Isolators : Isolators including marshalling box and suitable terminal connectors, as required as per technical specification with solid core cylindrical post insulators:A) 110KV, 1250A, 31.5KA Class Double Break Manually operated isolator With terminal connectors suitable for Drake ACSR.Errection of Upright mounting type with earth switch with live point height 4600mm | No | 11499.24 | 11499.24 | 1.0 | False | None | None | False | None | False | 11499.24 | 0 | 2748070 | 87414 | None | code045 | Assisting in Testing & Commissioning | No | 1719.4 | 1719.4 | 1.0 | False | None | None | False | None | False | 1719.4 | 0 | 2748071 | 87414 | None | code046 | Errection of Upright mounting type without earth switch with live point height 6350 mm | No | 11499.24 | 11499.24 | 1.0 | False | None | None | False | None | False | 11499.24 | 0 | 2748072 | 87414 | None | code047 | Assisting in Testing & Commissioning | No | 1719.4 | 1719.4 | 1.0 | False | None | None | False | None | False | 1719.4 | 0 | 2748073 | 87414 | None | code048 | Erection of Current Transformer :Current Transformer including Marshalling box, Single phase, oil filled outdoor type with rigid bimetallic terminal connectors suitable for Drake ACSR.Errection of 110 KV Class, 31.5 KA, CT of ratio 400-200/1-1-1A for Lines | No | 8450.31 | 8450.31 | 1.0 | False | None | None | False | None | False | 8450.31 | 0 | 2748074 | 87414 | None | code049 | Assisting in Testing and Commissioning | No | 1880.64 | 1880.64 | 1.0 | False | None | None | False | None | False | 1880.64 | 0 | 2748075 | 87414 | None | code050 | Erection of Lightning Arrestor : Surge arrestors (Porcelain housing) Metal Oxide Gap less type as per technical specification with suitable rigid bi-metallic terminal connectors suitable for Drake ACSR.
Erection of 96 KV, 10 KA, Class - II LA | No | 1760.37 | 1760.37 | 1.0 | False | None | None | False | None | False | 1760.37 | 0 | 2748076 | 87414 | None | code051 | Erection of Control Panels including wiring, assisting in testing commissioning:Simplex Type Control and Relay Panel complete as per specifications (Control Voltage 110 V DC).For 110 KV Transmission line | No | 7875.41 | 7875.41 | 1.0 | False | None | None | False | None | False | 7875.41 | 0 | 2748077 | 87414 | None | code052 | Wiring & assisting in testing and commissioning of panel. i) C& R Panels Wiring & Testing:Wiring: Identification, Ferruling, Crimping, termination of wires in C&R panels. | No | 11246.82 | 11246.82 | 1.0 | False | None | None | False | None | False | 11246.82 | 0 | 2748078 | 87414 | None | code053 | Testing of C&R Panels:Testing for insulation level, testing of relays, control operations for closing tripping etc, interlock, Alarm Annunciation and indication checks | No | 45546.3 | 45546.3 | 1.0 | False | None | None | False | None | False | 45546.3 | 0 | 2748079 | 87414 | None | code054 | Erection of Station Structures:Erection, assembly & alignment of Station Structures as per the direction of the Site Engineer. | Kg | 7.56 | 7.56 | 553.0 | False | None | None | False | None | False | 4180.68 | 0 | 2748080 | 87414 | None | code055 | Erection of mounting structures: Erection alignment, asssembly of fabricated Steel structures, pedestal structures & mounting structures for GOS. CT's, PT's, LA's etc | Kg | 7.56 | 7.56 | 1734.0 | False | None | None | False | None | False | 13109.04 | 0 | 2748081 | 87414 | None | code056 | Sorting of mounting structures of CT &LA (KPTCL supply) | Kg | 0.57 | 0.57 | 633.0 | False | None | None | False | None | False | 360.81 | 0 | 2748082 | 87414 | None | code057 | BUS BAR FORMATION:Formation of Main/Cross bus with Single Drake - 110kV | No | 15974.18 | 15974.18 | 1.0 | False | None | None | False | None | False | 15974.18 | 0 | 2748083 | 87414 | None | code058 | Laying of Copper Control Cables : 1.1kV PVC insulated Copper Control Cable with Lugs/Ferrules as per technical specifications.19 C x 2.5 Sqmm | m | 19.82 | 19.82 | 200.0 | False | None | None | False | None | False | 3964.0 | 0 | 2748084 | 87414 | None | code059 | Laying of Copper Control Cables 1.1kV PVC insulated Copper Control Cable with Lugs/Ferrules as per technical specifications.4 C x 6.0 Sqmm | m | 19.82 | 19.82 | 850.0 | False | None | None | False | None | False | 16847.0 | 0 | 2748085 | 87414 | None | code060 | Laying of Copper Control Cables :1.1kV PVC insulated Copper Control Cable with Lugs/Ferrules as per technical specifications.4 C x 2.5 Sqmm | m | 19.82 | 19.82 | 350.0 | False | None | None | False | None | False | 6937.0 | 0 | 2748086 | 87414 | None | code061 | YARD LIGHTS: a) Erection of Station yard lighting (outdoor type) fabricated Galvainsed Lattice structure type- 0.191MT per sturcture, (for 1 No of light) | Kg | 7.56 | 7.56 | 191.0 | False | None | None | False | None | False | 1443.96 | 0 | 2748087 | 87414 | None | code062 | fixing & wiring of Multi Functional Transducer(MFT) 0.2S Class | No | 2055.09 | 2055.09 | 1.0 | False | None | None | False | None | False | 2055.09 | 0 | 2748088 | 87414 | None | code063 | Fixing & wiring of Opto Coupler(220 or 110V DC) | No | 2055.09 | 2055.09 | 1.0 | False | None | None | False | None | False | 2055.09 | 0 | 2748089 | 87414 | None | code064 | laying of Current Cable- Copper core with 4.0sqmm cross section multistrand 7 Core for CT Termination | m | 33.04 | 33.04 | 5.0 | False | None | None | False | None | False | 165.2 | 0 | 2748090 | 87414 | None | code065 | Laying of Voltgae cables- Copper core with 2.5 sqmm cross section multistrand 4 core for PT Termination | m | 33.04 | 33.04 | 5.0 | False | None | None | False | None | False | 165.2 | 0 | 2748091 | 87414 | None | code066 | Laying of Signal/Communication Cables- Armoured copper Core with 0.5sqmm cross section multistrand 10core | m | 33.04 | 33.04 | 15.0 | False | None | None | False | None | False | 495.6 | 0 | 2748092 | 87414 | None | code067 | Laying of Control Cables-armoured copper core with 1.5sqmm cross section multistrand 10core | m | 33.04 | 33.04 | 15.0 | False | None | None | False | None | False | 495.6 | 0 | 2748093 | 87414 | None | code068 | Fixing of Data Concentrator Unit | No | 15991.36 | 15991.36 | 1.0 | False | None | None | False | None | False | 15991.36 | 0 | 2748094 | 87414 | None | code069 | Integration of RTU,DCU,UPS with field equipmets | No | 35697.74 | 35697.74 | 1.0 | False | None | None | False | None | False | 35697.74 | 0 | 2748095 | 87414 | None | code070 | Transportation:Transportation of materials from KPTCL MW Divisional stores, Kavoor to the Puttur station (52KM)(10MT Lorry) t.km | No | 15.86 | 15.86 | 520.0 | False | None | None | False | None | False | 8247.2 | 0 | 2748096 | 87414 | None | code071 | Transportation:Loading and Unloading of Breaker, CT, PT, Isolator and etc for loading at MW KPTCL stores, Kavoor and Un Loading at Puttur site. | Tonne | 769.17 | 769.17 | 3.5 | False | None | None | False | None | False | 2692.095 | 0 | 2748097 | 87414 | None | code072 | Transportation:Loading and Unloading of Mounting structures materials for loading at MW KPTCL stores, Kavoor and Un Loading at Puttur site | Tonne | 769.17 | 769.17 | 2.0 | False | None | None | False | None | False | 1538.34 | 0 | 2748098 | 87414 | None | code073 | Weighment of the materials at two different place | No | 2000.0 | 2000.0 | 1.0 | False | None | None | False | None | False | 2000.0 | 0 | 2748099 | 87414 | None | code074 | Releasing and Re-stringing of ACSR LYNX Conductor from Tower Loc No 16 to Loc No 17( 3 Spans) | No | 20926.21 | 20926.21 | 3.0 | False | None | None | False | None | False | 62778.63 | 0 | 2748100 | 87414 | None | code075 | Releasing and Re-stringing of ACSR LYNX Conductor from Tower Loc No 17 to 18 to Station Guantry (6 Spans) | No | 20926.21 | 20926.21 | 6.0 | False | None | None | False | None | False | 125557.26 | 0 | 2748101 | 87414 | None | code076 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 134.8 | 134.8 | 40.98 | False | None | None | False | None | False | 5524.104 | 0 | 2748102 | 87414 | None | code077 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7485.54 | 7485.54 | 2.13 | False | None | None | False | None | False | 15944.2002 | 0 | 2748103 | 87414 | None | code078 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, form work, centering & scaffolding and all the other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For foundation add at 3% | Cum | 8558.17 | 8558.17 | 3.01 | False | None | None | False | None | False | 25760.0917 | 0 | 2748104 | 87414 | None | code079 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, form work, centering & scaffolding and all the other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For column upto PB add at 70% | Cum | 14125.13 | 14125.13 | 11.51 | False | None | None | False | None | False | 162580.2463 | 0 | 2748105 | 87414 | None | code080 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 351.55 | 351.55 | 15.35 | False | None | None | False | None | False | 5396.2925 | 0 | 2748106 | 87414 | None | code081 | Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification All other type of structures | Kg | 104.42 | 104.42 | 516.64 | False | None | None | False | None | False | 53947.5488 | 0 | 2748107 | 87414 | None | code082 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc . complete for: PVC pipes 160mm dia., 10 Kg/m2 | m | 1280.63 | 1280.63 | 45.0 | False | None | None | False | None | False | 57628.35 | 0 | 2748108 | 87414 | None | code083 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 90mm dia., 6 kg/sqcm & class 3 | m | 388.55 | 388.55 | 30.0 | False | None | None | False | None | False | 11656.5 | 0 | 2748109 | 87414 | None | code084 | Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. Including the cost of CI frame and cover | No | 8191.28 | 8191.28 | 2.0 | False | None | None | False | None | False | 16382.56 | 0 | 2748110 | 87414 | None | code085 | Earth mat formation:Supplying and Grounding of Equipment with G.I.Flat 50x6mm and connecting Equipment to the earth mat/ground pit. Each point of earthing with all formation works like bending, twisting, drilling of holes and connecting by welding (inclusive of T&P and consumables) to the earthmat/Groundpit/point of earth connection. | m | 442.74 | 442.74 | 300.0 | False | None | None | False | None | False | 132822.0 | 0 | 2748111 | 87414 | None | code086 | Grounding of equipment by providing cast iron pipe of 100 mm ID 13 mm thickness, 2.75 metre long with 2 part clamp out of G.I. Flat 50 X 6 mm continuously welded alround the pipe using cast iron welding electrodes as per drawing including the cost of excavation (All materials to be supplied by the contractor) | No | 21519.61 | 21519.61 | 3.0 | False | None | None | False | None | False | 64558.83 | 0 | 2748112 | 87414 | None | code087 | Supplying & providing 450 mm dia 450 mm height 1.5 inch to 2 inch thick hume pipe collar (non pressure type) for earth pits including all lead and lifts etc | No | 1981.08 | 1981.08 | 3.0 | False | None | None | False | None | False | 5943.24 | 0 | 2748113 | 87414 | None | code088 | Loading and Unloading of Boulder by manual means. | Cum | 524.68 | 524.68 | 11.03 | False | None | None | False | None | False | 5787.2204 | 0 |
|
|
---|