| 2805824 | 90322 | None | Comon SR 2023-24 Pg 5 It No 1.4.2 | Earth work excavation by manual means for drains,canals and similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work Depth exceeding 1.5m, but not exceeding 3 m | Cum | 271.95 | 271.95 | 179.05 | False | None | None | False | None | False | 48692.6475 | 0 |
| 2805825 | 90322 | None | Comon SR 2023-24 Pg 15 It No 2.1.2 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries,curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm and down size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 33.92 | False | None | None | False | None | False | 201729.024 | 0 |
| 2805826 | 90322 | None | Comon SR 2023-24 Pg 15 It No 2.2.3 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 7185.02 | 7185.02 | 24.94 | False | None | None | False | None | False | 179194.3988 | 0 |
| 2805827 | 90322 | None | Comon SR 2023-24 Pg 15 It No 2.2.3a | RCC Column up to Plinthlavel | Cum | 11309.76 | 11309.76 | 5.38 | False | None | None | False | None | False | 60846.5088 | 0 |
| 2805828 | 90322 | None | Comon SR 2023-24 Pg 15 It No 2.2.3b | construction of RCC Ground level beam | Cum | 10644.48 | 10644.48 | 11.08 | False | None | None | False | None | False | 117940.8384 | 0 |
| 2805829 | 90322 | None | Comon SR 2023-24 Pg 15 It No 2.3.2 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floorsetc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10886.4 | 10886.4 | 10.8 | False | None | None | False | None | False | 117573.12 | 0 |
| 2805830 | 90322 | None | Comon SR 2023-24 Pg 15 It No 2.3.2a | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 12214.76 | 12214.76 | 13.22 | False | None | None | False | None | False | 161479.1272 | 0 |
| 2805831 | 90322 | None | Comon SR 2023-24 Pg 15 It No 2.3.2b | RCC chejja including Formwork | Cum | 10418.47 | 10418.47 | 1.46 | False | None | None | False | None | False | 15210.9662 | 0 |
| 2805832 | 90322 | None | Comon SR 2023-24 Pg 17 It No 2.5.2b | Construction of RCC Lintel Beam RCC Roof Beam including centring | Cum | 11496.24 | 11496.24 | 36.6 | False | None | None | False | None | False | 420762.384 | 0 |
| 2805833 | 90322 | None | Comon SR 2023-24 Pg 17 It No 2.5.2d | Construction of RCC Roof and staircase including centring | Cum | 10777.73 | 10777.73 | 82.01 | False | None | None | False | None | False | 883881.6373 | 0 |
| 2805834 | 90322 | None | Comon SR 2023-24 vol-1 Pg It No 2.11 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specification | t | 93929.85 | 93929.85 | 17.6366 | False | None | None | False | None | False | 1656603.19251 | 0 |
| 2805835 | 90322 | None | Comon SR 2023-24 vol-2 Pg 13 It No 6.2 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8376.9 | 8376.9 | 12.4 | False | None | None | False | None | False | 103873.56 | 0 |
| 2805836 | 90322 | None | Comon SR 2023-24 vol-1 Pg 77 It No 1.9 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 454.65 | 454.65 | 318.82 | False | None | None | False | None | False | 144951.513 | 0 |
| 2805837 | 90322 | None | Comon SR 2023-24 vol-2 Pg 13 It No 6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8367.45 | 8367.45 | 105.01 | False | None | None | False | None | False | 878665.9245 | 0 |
| 2805838 | 90322 | None | Comon SR 2023-24 vol-2 Pg 14 It No 6.11 | Providing Brick work 7 cm thick with common burnt clay Non Modular brick of class designation 3.5 in cement mortar 1:3 (1 cement : 3 coarsesand) in superstructure above plinth level including cost of all materials,labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Sqm | 814.8 | 814.8 | 63.55 | False | None | None | False | None | False | 51780.54 | 0 |
| 2805839 | 90322 | None | Comon SR 2023-24 vol-1 Pg 15 It No 2.1.4 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6527.85 | 6527.85 | 2.57 | False | None | None | False | None | False | 16776.5745 | 0 |
| 2805840 | 90322 | None | Comon SR 2023-24 vol-2 Pg 85 It No 11.34a | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kg | 176.4 | 176.4 | 1192.32 | False | None | None | False | None | False | 210325.248 | 0 |
| 2805841 | 90322 | None | Comon SR 2023-24 vol-2 Pg 42 It No 8.8 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 389.55 | 389.55 | 1332.79 | False | None | None | False | None | False | 519188.3445 | 0 |
| 2805842 | 90322 | None | Comon SR 2023-24 vol-2 Pg 63 It No 9.23 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. | Sqm | 2589.3 | 2589.3 | 506.3 | False | None | None | False | None | False | 1310962.59 | 0 |
| 2805843 | 90322 | None | Comon SR 2023-24 vol-2 Pg 112 It No 12.90 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size -2419mm x 2200mm. (The cost is inclusive of all fixtures and | Sqm | 7070.7 | 7070.7 | 40.32 | False | None | None | False | None | False | 285090.624 | 0 |
| 2805844 | 90322 | None | Comon SR 2023-24 vol-2 Pg 91 It No 11.44 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/m²) including cost of materials, labour, usage charges of machinery complete as per specifications. | Sqm | 4562.25 | 4562.25 | 5.76 | False | None | None | False | None | False | 26278.56 | 0 |
| 2805845 | 90322 | None | Comon SR 2023-24 vol-2 Pg 105 It No 12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. | Each | 1066.8 | 1066.8 | 8.0 | False | None | None | False | None | False | 8534.4 | 0 |
| 2805846 | 90322 | None | Comon SR 2023-24 vol-2 Pg 99 It No 12.12 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves ( excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 130412.1 | 130412.1 | 0.91 | False | None | None | False | None | False | 118675.011 | 0 |
| 2805847 | 90322 | None | Comon SR 2023-24 vol-2 Pg 100 It No 12.21 | Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with , stiles and rails of 30mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels
of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) | Sqm | 6029.1 | 6029.1 | 17.6 | False | None | None | False | None | False | 106112.16 | 0 |
| 2805848 | 90322 | None | Comon SR 2023-24 vol-2 Pg 70 It No 10.11 | Providing and fixing plywood 4 mm thick, one side decorative veneer conforming to IS: 1328 (type-1), for plain lining / cladding with necessary screws, including priming coat on unexposed surface with Decorative veneer facings of approved manufacture | Sqm | 1554.0 | 1554.0 | 1.5 | False | None | None | False | None | False | 2331.0 | 0 |
| 2805849 | 90322 | None | Comon SR 2023-24 vol-2 Pg 45 It No 8.24 | Distempering with dry distemper of approved brand and manufacture (two coats) of required shade on new work, over and including water thinnable priming coat to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 113.4 | 113.4 | 743.2 | False | None | None | False | None | False | 84278.88 | 0 |
| 2805850 | 90322 | None | Comon SR 2023-24 vol-2 Pg 48 It No 8.39 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 133.35 | 133.35 | 1217.98 | False | None | None | False | None | False | 162417.633 | 0 |
| 2805851 | 90322 | None | Comon SR 2023-24 vol-2 Pg 48 It No 8.41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 175.35 | 175.35 | 39.42 | False | None | None | False | None | False | 6912.297 | 0 |
| 2805852 | 90322 | None | Comon SR 2023-24 vol-2 Pg 65 It No 9.40 | Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, griding the edge to half/full round wherever required, labour, curing complete
as per specification | Sqm | 978.6 | 978.6 | 20.1 | False | None | None | False | None | False | 19669.86 | 0 |
| 2805853 | 90322 | None | Comon SR 2023-24 vol-2 Pg 82 It No 11.26.1 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineerin- Charge | Kg | 144.9 | 144.9 | 811.2 | False | None | None | False | None | False | 117542.88 | 0 |
| 2805854 | 90322 | None | Comon SR 2023-24 vol-2 Pg 81 It No 11.18 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Each | 180.6 | 180.6 | 20.0 | False | None | None | False | None | False | 3612.0 | 0 |
| 2805855 | 90322 | None | Comon SR 2023-24 vol-2 Pg 108 It No 12.69.3 | Providing and fixing ISI marked oxidised M.S. single acting spring hinges with necessary screws etc.100mm | Each | 226.8 | 226.8 | 62.0 | False | None | None | False | None | False | 14061.6 | 0 |
| 2805856 | 90322 | None | Comon SR 2023-24 vol-2 Pg 108 It No 12.72 | Providing and fixing ISI oxidised M.S.pressed tower bolt blackfinish,with necessary screwsetc complete | Each | 86.1 | 86.1 | 62.0 | False | None | None | False | None | False | 5338.2 | 0 |
| 2805857 | 90322 | None | Comon SR 2023-24 vol-2 Pg 108 It No 12.73 | Providing and fixing ISI oxidised M.S.handles with necessary screwsetc complete 100 mm | Each | 38.85 | 38.85 | 32.0 | False | None | None | False | None | False | 1243.2 | 0 |
| 2805858 | 90322 | None | Market rate 2022-23 | Providing and fixing green wall boards Anti curl , maisture Proof 4ft*12ft | Each | 12000.0 | 12000.0 | 4.0 | False | None | None | False | None | False | 48000.0 | 0 |
| 2805859 | 90322 | None | Comon SR 2023-24 vol-2 Pg It No 13.47 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipe conforming to IS : 13592 Type A including joining with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion (i) single socketed pipes 75mm diameter cost of materials, labour, complete as per specifications. | Rmtr | 206.85 | 206.85 | 48.0 | False | None | None | False | None | False | 9928.8 | 0 |
| 2805860 | 90322 | None | Comon SR 2023-24 vol-2 Pg It No 7.33.1 | Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated 'J' or 'L' hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified 2 mm thick corrugated (2.5"" or 4.2"" or 6"") or step-down (2"" or 3"" or 6"" ) as specified | Sqm | 1110.9 | 1110.9 | 22.5 | False | None | None | False | None | False | 24995.25 | 0 |
| 2805861 | 90322 | None | Comon SR 2023-24 vol-2 Pg 151 It No 8.54 | Providing and fixing board displaying information, such as 'Name of work, Tender cost, Name of Contractor, Work completion and liability period etc', having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shade paint complete, on M.S.angle of size 35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including, excavation, refilling, transportation, and labour etc complete. Spec. No. As directed by Engineer in Charge MoRTH specification 804 | No | 9450.0 | 9450.0 | 1.0 | False | None | None | False | None | False | 9450.0 | 0 |
| 2805862 | 90322 | None | Pwd Ele SR 2023-24 Pg 1 It No 1.2.3 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable sizebends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary.32 mm dia 2.5 mm thick | Rmtr | 108.15 | 108.15 | 200.0 | False | None | None | False | None | False | 21630.0 | 0 |
| 2805863 | 90322 | None | Pwd Ele SR 2023-24 Pg 1 It No 1.3.2 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25 mm dia 2 mm thick | Rmtr | 82.95 | 82.95 | 150.0 | False | None | None | False | None | False | 12442.5 | 0 |
| 2805864 | 90322 | None | Pwd Ele SR 2023-24 Pg 1 It No 1.4.4 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.180 x 90 x 65 mm | No | 158.55 | 158.55 | 16.0 | False | None | None | False | None | False | 2536.8 | 0 |
| 2805865 | 90322 | None | Pwd Ele SR 2023-24 Pg 1 It No 1.5.2 | Supplying and fixing PVC/metal conduit Deep junction box 25 mm deep Junction box | No | 58.8 | 58.8 | 32.0 | False | None | None | False | None | False | 1881.6 | 0 |
| 2805866 | 90322 | None | Pwd Ele SR 2023-24 Pg 1 It No 1.7.1 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete.upto 50 mm conduit in brick wall | Rmtr | 30.45 | 30.45 | 150.0 | False | None | None | False | None | False | 4567.5 | 0 |
| 2805867 | 90322 | None | Pwd Ele SR 2023-24 Pg 2 It No 2.1 | Point wiring using Copper wire with switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point upto 3m from tapping point to out let via switch. | No | 299.25 | 299.25 | 16.0 | False | None | None | False | None | False | 4788.0 | 0 |
| 2805868 | 90322 | None | Pwd Ele SR 2023-24 Pg 2 It No 2.1.2 | Point wiring using Copper wire with switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Medium point above 3m upto 6m from tapping point to out let via switch | No | 413.7 | 413.7 | 8.0 | False | None | None | False | None | False | 3309.6 | 0 |
| 2805869 | 90322 | None | Pwd Ele SR 2023-24 Pg 2 It No 2.3.4 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wring with specified IS-694:1990 & confirming to GTP of GROUP-A | Rmtr | 44.1 | 44.1 | 350.0 | False | None | None | False | None | False | 15435.0 | 0 |
| 2805870 | 90322 | None | Pwd Ele SR 2023-24 Pg 2 It No 3.2 | Supplying and mounting 2 Nos. of 2 way 6 amps flush type switches either surface/flush mounted on existing gang box or in 4mm thick plastic sheet and mounted on a flush mounted wooden box and wiring as per IS 1293 | No | 178.5 | 178.5 | 8.0 | False | None | None | False | None | False | 1428.0 | 0 |
| 2805871 | 90322 | None | Pwd Ele SR 2023-24 Pg 2 It No 3.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.1 to 3 Module | No | 169.05 | 169.05 | 8.0 | False | None | None | False | None | False | 1352.4 | 0 |
| 2805872 | 90322 | None | Pwd Ele SR 2023-24 Pg 2 It No 3.6 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 | No | 163.8 | 163.8 | 8.0 | False | None | None | False | None | False | 1310.4 | 0 |
| 2805873 | 90322 | None | Pwd Ele SR 2023-24 Pg 2 It No 5.18.2 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts,nuts etc., with provision for fixing suitable type capacityMCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.I - Single Door 6Way SP &N | No | 1245.3 | 1245.3 | 1.0 | False | None | None | False | None | False | 1245.3 | 0 |
| 2805874 | 90322 | None | Pwd Ele SR 2023-24 Pg 2 It No 5.21 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board | No | 9717.75 | 9717.75 | 1.0 | False | None | None | False | None | False | 9717.75 | 0 |
| 2805875 | 90322 | None | Pwd Ele SR 2023-24 Pg 2 It No 11.13.1 | Supplying and fixing of slim patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired.Excluding Ballast & Fluorescent Tube.1 x 4' Tube light fitting | No | 277.2 | 277.2 | 16.0 | False | None | None | False | None | False | 4435.2 | 0 |
| 2805876 | 90322 | None | Pwd Ele SR 2023-24 Pg 2 It No 11.10.2 | Supplying & fixing of Surface mounting type retrofit type -LED tube ....... W comprising of LED linear source with CCT 6500 degree K, CRIgreater than 70%. efficacy greater than80 lumen per W, lifegreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should Less than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. Glass Casing 18W-20W | No | 346.5 | 346.5 | 16.0 | False | None | None | False | None | False | 5544.0 | 0 |
| 2805877 | 90322 | None | Pwd Ele SR 2023-24 Pg 2 It No 6.3.1 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies for operation on 230 Volts, 50 Cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system | No | 3133.2 | 3133.2 | 16.0 | False | None | None | False | None | False | 50131.2 | 0 |