2784535 | 88922 | None | code01 | CIVIL WORKS - SECOND FLOOR: Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & dowel bars to be paid separately) RCC Column M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Also includes cost of Formwork, Centering and Scafolding. SECOND FLOOR | Cum | 12072.42 | 12072.42 | 28.4041 | False | None | None | False | None | False | 342906.224922 | 0 |
2784536 | 88922 | None | code02 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & dowel bars to be paid separately) RCC Column M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Also includes cost of Formwork, Centering and Scafolding. HEAD ROOM | Cum | 12193.14 | 12193.14 | 4.14 | False | None | None | False | None | False | 50479.5996 | 0 |
2784537 | 88922 | None | code03 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & dowel bars to be paid separately) RCC Lintel M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Also includes cost of Formwork, Centering and Scafolding. SECOND FLOOR | Cum | 11362.28 | 11362.28 | 6.96 | False | None | None | False | None | False | 79081.4688 | 0 |
2784538 | 88922 | None | code04 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & dowel bars to be paid separately) RCC Lintel M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Also includes cost of Formwork, Centering and Scafolding. HEAD ROOM | Cum | 11475.9 | 11475.9 | 0.71 | False | None | None | False | None | False | 8147.889 | 0 |
2784539 | 88922 | None | code05 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & dowel bars to be paid separately) RCC Roof Beam M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Also includes cost of Formwork, Centering and Scafolding. SECOND FLOOR | Cum | 11362.28 | 11362.28 | 20.87 | False | None | None | False | None | False | 237130.7836 | 0 |
2784540 | 88922 | None | code06 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & dowel bars to be paid separately) RCC Roof Beam M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Also includes cost of Formwork, Centering and Scafolding. HEAD ROOM | Cum | 11475.9 | 11475.9 | 0.89 | False | None | None | False | None | False | 10213.551 | 0 |
2784541 | 88922 | None | code07 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & dowel bars to be paid separately) RCC Roof Slab M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Also includes cost of Formwork, Centering and Scafolding. SECOND FLOOR | Cum | 10652.13 | 10652.13 | 58.07 | False | None | None | False | None | False | 618569.1891 | 0 |
2784542 | 88922 | None | code08 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & dowel bars to be paid separately) RCC Roof Slab M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Also includes cost of Formwork, Centering and Scafolding. HEAD ROOM | Cum | 10758.66 | 10758.66 | 3.67 | False | None | None | False | None | False | 39484.2822 | 0 |
2784543 | 88922 | None | code09 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & dowel bars to be paid separately) RCC Plain Chajja M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Also includes cost of Formwork, Centering and Scafolding. SECOND FLOOR | Sqm | 10297.06 | 10297.06 | 1.04 | False | None | None | False | None | False | 10708.9424 | 0 |
2784544 | 88922 | None | code10 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & dowel bars to be paid separately) RCC Plain Chajja M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Also includes cost of Formwork, Centering and Scafolding. HEAD ROOM | Sqm | 10400.03 | 10400.03 | 0.1 | False | None | None | False | None | False | 1040.003 | 0 |
2784545 | 88922 | None | code11 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & dowel bars to be paid separately) RCC Racks M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Also includes cost of Formwork, Centering and Scafolding. SECOND FLOOR | Sqm | 10297.06 | 10297.06 | 2.88 | False | None | None | False | None | False | 29655.5328 | 0 |
2784546 | 88922 | None | code12 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & dowel bars to be paid separately) RCC Loft (Atta) Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Also includes cost of Formwork, Centering and Scafolding. SECOND FLOOR | Sqm | 10297.06 | 10297.06 | 1.15 | False | None | None | False | None | False | 11841.619 | 0 |
2784547 | 88922 | None | code13 | FLAGGING CONCRETE Providing and laying Cement concrete flooring 40 mm thick with 20 mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry complete. (Vol.2, P 59, I 9.1) | Sqm | 473.55 | 473.55 | 65.0 | False | None | None | False | None | False | 30780.75 | 0 |
2784548 | 88922 | None | code14 | Supplying, fitting and placing TMT FE550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. SECOND FLOOR | Kg | 95.82 | 95.82 | 12058.62 | False | None | None | False | None | False | 1155456.9684 | 0 |
2784549 | 88922 | None | code15 | Supplying, fitting and placing TMT FE550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. HEAD ROOM | Kg | 96.78 | 96.78 | 827.99 | False | None | None | False | None | False | 80132.8722 | 0 |
2784550 | 88922 | None | code16 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc. complete as per specifications. SECOND FLOOR | Sqm | 1403.15 | 1403.15 | 706.92 | False | None | None | False | None | False | 991914.798 | 0 |
2784551 | 88922 | None | code17 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc. complete as per specifications. HEAD ROOM | Sqm | 1417.18 | 1417.18 | 45.6 | False | None | None | False | None | False | 64623.408 | 0 |
2784552 | 88922 | None | code18 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc. complete as per specifications. SECOND FLOOR | Sqm | 1182.5 | 1182.5 | 89.48 | False | None | None | False | None | False | 105810.1 | 0 |
2784553 | 88922 | None | code19 | Providing Salwood frames for doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. SECOND FLOOR | Cum | 105841.24 | 105841.24 | 0.41 | False | None | None | False | None | False | 43394.9084 | 0 |
2784554 | 88922 | None | code20 | Providing Salwood frames for doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. HEAD ROOM | Cum | 106899.65 | 106899.65 | 0.05 | False | None | None | False | None | False | 5344.9825 | 0 |
2784555 | 88922 | None | code21 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead up to 50 m. including cost of materials, labour charges, complete as per specifications. | Nos | 1066.8 | 1066.8 | 18.0 | False | None | None | False | None | False | 19202.4 | 0 |
2784556 | 88922 | None | code22 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned, chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. 30mm thick both side teak. SECOND FLOOR | Sqm | 4330.48 | 4330.48 | 29.46 | False | None | None | False | None | False | 127575.9408 | 0 |
2784557 | 88922 | None | code23 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No's of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. SECOND FLOOR | Sqm | 333.9 | 333.9 | 25.2 | False | None | None | False | None | False | 8414.28 | 0 |
2784558 | 88922 | None | code24 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm as & rails with PVC Designer beading on either side & joined together Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet wide cross PVC sheet with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 no's of 75mm Aluminium hinges. with one side prelam. SECOND FLOOR | Sqm | 2185.05 | 2185.05 | 22.96 | False | None | None | False | None | False | 50168.748 | 0 |
2784559 | 88922 | None | code25 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made. SECOND FLOOR | Sqm | 7212.82 | 7212.82 | 25.38 | False | None | None | False | None | False | 183061.3716 | 0 |
2784560 | 88922 | None | code26 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL 9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made. HEAD ROOM | Sqm | 7284.95 | 7284.95 | 1.98 | False | None | None | False | None | False | 14424.201 | 0 |
2784561 | 88922 | None | code27 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made). SECOND FLOOR | Sqm | 6125.65 | 6125.65 | 13.2 | False | None | None | False | None | False | 80858.58 | 0 |
2784562 | 88922 | None | code28 | Providing and laying Polished Sadarahalli Grey Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. SECOND FLOOR | Sqm | 2233.25 | 2233.25 | 177.67 | False | None | None | False | None | False | 396781.5275 | 0 |
2784563 | 88922 | None | code29 | Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications. SECOND FLOOR | Sqm | 1654.86 | 1654.86 | 1.0 | False | None | None | False | None | False | 1654.86 | 0 |
2784564 | 88922 | None | code30 | Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications. HEAD ROOM | Sqm | 1671.41 | 1671.41 | 16.0 | False | None | None | False | None | False | 26742.56 | 0 |
2784565 | 88922 | None | code31 | Providing and laying flooring and steps machine cut granite slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar labour, curing complete as per specifications. SECOND FLOOR | Sqm | 4583.26 | 4583.26 | 3.6 | False | None | None | False | None | False | 16499.736 | 0 |
2784566 | 88922 | None | code32 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tiles 600x600 mm | Sqm | 1226.41 | 1226.41 | 173.18 | False | None | None | False | None | False | 212389.6838 | 0 |
2784567 | 88922 | None | code33 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. | Sqm | 952.21 | 952.21 | 30.82 | False | None | None | False | None | False | 29347.1122 | 0 |
2784568 | 88922 | None | code34 | Providing skirting, dado, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with while cement slurry over rough plaster surface (excluding cost of rough plastered surface which should be measured and paid separately) using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications and direction of Engineer in charge. Size 15x15cms | Sqm | 1552.03 | 1552.03 | 120.6 | False | None | None | False | None | False | 187174.818 | 0 |
2784569 | 88922 | None | code35 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. INTERNAL PLASTERING SECOND FLOOR | Sqm | 273.13 | 273.13 | 1394.58 | False | None | None | False | None | False | 380901.6354 | 0 |
2784570 | 88922 | None | code36 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. INTERNAL PLASTERING HEAD ROOM | Sqm | 275.86 | 275.86 | 13.74 | False | None | None | False | None | False | 3790.3164 | 0 |
2784571 | 88922 | None | code37 | Providing 15 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. EXTERNAL PLASTERING SECOND FLOOR | Sqm | 315.98 | 315.98 | 783.52 | False | None | None | False | None | False | 247576.6496 | 0 |
2784572 | 88922 | None | code38 | Providing 15 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. EXTERNAL PLASTERING HEAD ROOM | Sqm | 319.14 | 319.14 | 53.0 | False | None | None | False | None | False | 16914.42 | 0 |
2784573 | 88922 | None | code39 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. FOR CEILING SECOND FLOOR | Sqm | 273.14 | 273.14 | 204.5 | False | None | None | False | None | False | 55857.13 | 0 |
2784574 | 88922 | None | code40 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. FOR CEILING HEAD ROOM | Sqm | 275.87 | 275.87 | 18.12 | False | None | None | False | None | False | 4998.7644 | 0 |
2784575 | 88922 | None | code41 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. SECOND FLOOR | Sqm | 107.11 | 107.11 | 1599.08 | False | None | None | False | None | False | 171277.4588 | 0 |
2784576 | 88922 | None | code42 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Head Room | Sqm | 108.18 | 108.18 | 31.86 | False | None | None | False | None | False | 3446.6148 | 0 |
2784577 | 88922 | None | code43 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fne sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifcations and as per directions of Engineer-in-charge. Second floor | Sqm | 298.84 | 298.84 | 120.6 | False | None | None | False | None | False | 36040.104 | 0 |
2784578 | 88922 | None | code44 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 litre/10 m² over and including one coat of Special primer applied @ 0.75 litre /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Second Floor | Sqm | 169.23 | 169.23 | 1394.58 | False | None | None | False | None | False | 236004.7734 | 0 |
2784579 | 88922 | None | code45 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 litre/10 m² over and including one coat of Special primer applied @ 0.75 litre /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Head room | Sqm | 170.93 | 170.93 | 13.74 | False | None | None | False | None | False | 2348.5782 | 0 |
2784580 | 88922 | None | code46 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 litre/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 186.38 | 186.38 | 783.52 | False | None | None | False | None | False | 146032.4576 | 0 |
2784581 | 88922 | None | code47 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 litre/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Head room | Sqm | 188.24 | 188.24 | 53.0 | False | None | None | False | None | False | 9976.72 | 0 |
2784582 | 88922 | None | code48 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 litre/10 m² over and including one coat of Special primer applied @ 0.75 litre /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Second floor | Sqm | 169.23 | 169.23 | 204.5 | False | None | None | False | None | False | 34607.535 | 0 |
2784583 | 88922 | None | code49 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 litre/10 m² over and including one coat of Special primer applied @ 0.75 litre /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Head room | Sqm | 170.93 | 170.93 | 18.12 | False | None | None | False | None | False | 3097.2516 | 0 |
2784584 | 88922 | None | code50 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 litre/10 m² over an under coat of primer applied @0.75 litre/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Second Floor | Sqm | 147.81 | 147.81 | 55.13 | False | None | None | False | None | False | 8148.7653 | 0 |
2784585 | 88922 | None | code51 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 litre/10 m² over an under coat of primer applied @0.75 litre/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Head room | Sqm | 149.29 | 149.29 | 2.73 | False | None | None | False | None | False | 407.5617 | 0 |
2784586 | 88922 | None | code52 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. Second floor | Kg | 192.15 | 192.15 | 532.98 | False | None | None | False | None | False | 102412.107 | 0 |
2784587 | 88922 | None | code53 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. Head room | Kg | 192.15 | 192.15 | 34.65 | False | None | None | False | None | False | 6657.9975 | 0 |
2784588 | 88922 | None | code54 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 litre/10 m² over an under coat of primer applied @ 0.80 litre/10 m² of approved brand and manufacture including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Second Floor | Sqm | 148.88 | 148.88 | 25.38 | False | None | None | False | None | False | 3778.5744 | 0 |
2784589 | 88922 | None | code55 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 litre/10 m² over an under coat of primer applied @ 0.80 litre/10 m² of approved brand and manufacture including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Head room | Sqm | 150.37 | 150.37 | 1.98 | False | None | None | False | None | False | 297.7326 | 0 |
2784590 | 88922 | None | code56 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 605.17 | 605.17 | 52.2 | False | None | None | False | None | False | 31589.874 | 0 |
2784591 | 88922 | None | code57 | Providing and fixing plaster mesh 200mm wide manufactured out of hot dipped galvanized iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. | m | 46.2 | 46.2 | 720.0 | False | None | None | False | None | False | 33264.0 | 0 |
2784592 | 88922 | None | code58 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Cum | 883.84 | 883.84 | 43.5 | False | None | None | False | None | False | 38447.04 | 0 |
2784593 | 88922 | None | code59 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 6697.02 | 6697.02 | 32.63 | False | None | None | False | None | False | 218523.7626 | 0 |
2784594 | 88922 | None | code60 | Providing & fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter. | m | 305.55 | 305.55 | 75.0 | False | None | None | False | None | False | 22916.25 | 0 |
2784595 | 88922 | None | code61 | Providing and fixing oxidised M.S. double acting spring hinges with necessary screws etc. complete. 150mm. | Nos | 319.2 | 319.2 | 225.0 | False | None | None | False | None | False | 71820.0 | 0 |
2784596 | 88922 | None | code62 | Providing and fixing chromium plated brass 100 mm mortise latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. | Nos | 1104.6 | 1104.6 | 75.0 | False | None | None | False | None | False | 82845.0 | 0 |
2784597 | 88922 | None | code63 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete. | Nos | 136.5 | 136.5 | 75.0 | False | None | None | False | None | False | 10237.5 | 0 |
2784598 | 88922 | None | code64 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. | Nos | 126.0 | 126.0 | 30.0 | False | None | None | False | None | False | 3780.0 | 0 |
2784599 | 88922 | None | code65 | CIVIL WORKS : Providing and laying Permeable Cement Concrete Paver Block for Pedestrian Footpaths of approved shape and colour, laid in required pattern and including over 30mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. In front parking area | Sqm | 1069.95 | 1069.95 | 90.57 | False | None | None | False | None | False | 96905.3715 | 0 |
2784600 | 88922 | None | code66 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates. Pavement | Cum | 6527.85 | 6527.85 | 62.9 | False | None | None | False | None | False | 410601.765 | 0 |
2784601 | 88922 | None | code67 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifcations, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Soft Rock 70% (without blasting). All around the building existing rock, It also includes Dewatering | Cum | 479.72 | 479.72 | 555.0 | False | None | None | False | None | False | 266244.6 | 0 |
2784602 | 88922 | None | code68 | WATER SUPPLY : Earth work excavation for pipelines/cables by mechanical means upto 600mm trench width, as per drawing and technical specifcations, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. All Kind of soils. Depth upto 1.50m | Cum | 275.1 | 275.1 | 27.0 | False | None | None | False | None | False | 7427.7 | 0 |
2784603 | 88922 | None | code69 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for PVC pipes 25mm dia, 10 kg/sqcm & class 5. | m | 50.4 | 50.4 | 150.0 | False | None | None | False | None | False | 7560.0 | 0 |
2784604 | 88922 | None | code70 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for PVC pipes 32mm dia., 10 kg/sqcm & class 5 | m | 70.35 | 70.35 | 250.0 | False | None | None | False | None | False | 17587.5 | 0 |
2784605 | 88922 | None | code71 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for PVC pipes 50mm dia., 6 kg/sqcm & class 5 | m | 106.05 | 106.05 | 150.0 | False | None | None | False | None | False | 15907.5 | 0 |
2784606 | 88922 | None | code72 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for PVC pipes75 mm dia. | m | 231.0 | 231.0 | 100.0 | False | None | None | False | None | False | 23100.0 | 0 |
2784607 | 88922 | None | code73 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00m spacing. This included jointing of pipes & fittinfs with one step CPVC solvent cement and testing of joints complete as per direction of Enginner in Charge. 15 mm nominal dia Pipes | m | 191.1 | 191.1 | 5.0 | False | None | None | False | None | False | 955.5 | 0 |
2784608 | 88922 | None | code74 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00m spacing. This included jointing of pipes & fittinfs with one step CPVC solvent cement and testing of joints complete as per direction of Enginner in Charge. 20 mm nominal dia Pipes | m | 254.1 | 254.1 | 5.0 | False | None | None | False | None | False | 1270.5 | 0 |
2784609 | 88922 | None | code75 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00m spacing. This included jointing of pipes & fittinfs with one step CPVC solvent cement and testing of joints complete as per direction of Enginner in Charge. 25 mm nominal dia Pipes | m | 333.9 | 333.9 | 5.0 | False | None | None | False | None | False | 1669.5 | 0 |
2784610 | 88922 | None | code76 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00m spacing. This included jointing of pipes & fittinfs with one step CPVC solvent cement and testing of joints complete as per direction of Enginner in Charge. 32 mm nominal dia Pipes | m | 420.0 | 420.0 | 5.0 | False | None | None | False | None | False | 2100.0 | 0 |
2784611 | 88922 | None | code77 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00m spacing. This included jointing of pipes & fittinfs with one step CPVC solvent cement and testing of joints complete as per direction of Enginner in Charge. 50 mm nominal dia Pipes | m | 820.05 | 820.05 | 5.0 | False | None | None | False | None | False | 4100.25 | 0 |
2784612 | 88922 | None | code78 | Providing GM (copper alloy) wheel valves/ check valve confrming to IS 778/1990 Class-I with latest amendments No. 1 and with ISI mark screwed in bonnet integral seat inside, screw, rising spindle screwed female ends confrming to IS 554/ 1990 body hudraulically tested 1.50 HP seat hydraulically tested 1.00 HP. For 80 mm dia GM (Copper alloy) Gate valves | Each | 1997.1 | 1997.1 | 7.0 | False | None | None | False | None | False | 13979.7 | 0 |
2784613 | 88922 | None | code79 | Supply and delivery at site GM (copper alloy) gate valves confrming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confrming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 50 mm dia GM (Copper alloy) Gate valves | Each | 1772.4 | 1772.4 | 2.0 | False | None | None | False | None | False | 3544.8 | 0 |
2784614 | 88922 | None | code80 | Providing and fxing PTMT pillar cock of approved quality and colour. 15 mm nominal bore, 125 mm long foam flow, weighing not less than 120 gms. | Each | 329.7 | 329.7 | 15.0 | False | None | None | False | None | False | 4945.5 | 0 |
2784615 | 88922 | None | code81 | Providing and fxing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fttings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. | Each | 5128.2 | 5128.2 | 8.0 | False | None | None | False | None | False | 41025.6 | 0 |
2784616 | 88922 | None | code82 | Providing and fxing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fttings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fttings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid. | Each | 6275.85 | 6275.85 | 2.0 | False | None | None | False | None | False | 12551.7 | 0 |
2784617 | 88922 | None | code83 | Providing and fxing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fttings and brackets, cutting and making good the walls wherever require: White Vitreous China Angle back wash basin size 600 x 480 mm with single 15mm C.P. brass pillar tap. | Each | 2410.8 | 2410.8 | 15.0 | False | None | None | False | None | False | 36162.0 | 0 |
2784618 | 88922 | None | code84 | Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete. | Each | 231.0 | 231.0 | 20.0 | False | None | None | False | None | False | 4620.0 | 0 |
2784619 | 88922 | None | code85 | Providing and fxing PTMT towel rail complete with brackets fxed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. | Each | 520.8 | 520.8 | 15.0 | False | None | None | False | None | False | 7812.0 | 0 |
2784620 | 88922 | None | code86 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Rectangular shape 453x357 mm | Each | 1068.9 | 1068.9 | 5.0 | False | None | None | False | None | False | 5344.5 | 0 |
2784621 | 88922 | None | code87 | Lowering, laying and fusion welding Jointing for HDPE Pipes Grade PE-80 / PE-100 conforming to IS 4984-2016, of specifed dia. including hydrualic testing and commissioning etc.(Contractor will make his own arrangements for procuring water for testing) for: 110mm dia. | m | 99.75 | 99.75 | 110.0 | False | None | None | False | None | False | 10972.5 | 0 |
2784622 | 88922 | None | code88 | Providing and fxing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fttings of approved quality and colour, weighing not less than 105 gms. | Each | 152.25 | 152.25 | 3.0 | False | None | None | False | None | False | 456.75 | 0 |
2784623 | 88922 | None | code89 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arranfement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support tank. | l | 9.45 | 9.45 | 8000.0 | False | None | None | False | None | False | 75600.0 | 0 |
2784624 | 88922 | None | code90 | Supplying, installation, testing and commissioning of solar hot water heater comprising of high quality Evacuated Glass Tube (EGT) with absorber coating collector of size 58 x 1800 mm. Inner tank Material-Stainless steel 304-L Grade with Aluminium Stucco cladding made of High quality PUF insulation to minimizes heat loss and hold water Temperature upto 72 Hrs...with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. Fitted with Sacrificial Anode. 200 L- 20 nos Tubes | Each | 45383.1 | 45383.1 | 1.0 | False | None | None | False | None | False | 45383.1 | 0 |
2784625 | 88922 | None | code91 | Supplying, installation, testing and commissioning of solar hot water heater comprising of high quality Evacuated Glass Tube (EGT) with absorber coating collector of size 58 x 1800 mm. Inner tank Material-Stainless steel 304-L Grade with Aluminium Stucco cladding made of High quality PUF insulation to minimizes heat loss and hold water Temperature upto 72 Hrs...with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. Fitted with Sacrificial Anode. 300 L- 29 nos Tubes | Each | 54104.4 | 54104.4 | 1.0 | False | None | None | False | None | False | 54104.4 | 0 |
2784626 | 88922 | None | code92 | Providing & fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology. | Nos | 9686.25 | 9686.25 | 4.0 | False | None | None | False | None | False | 38745.0 | 0 |
2784627 | 88922 | None | code93 | UGD - Earth work excavation for pipelines/cables by mechanical means upto 600mm trench width, as per drawing and technical specifcations, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. All Kind of soils. Depth upto 1.50m | Cum | 275.1 | 275.1 | 27.0 | False | None | None | False | None | False | 7427.7 | 0 |
2784628 | 88922 | None | code94 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: Pipes of SN4, 75mm dia. | m | 227.85 | 227.85 | 100.0 | False | None | None | False | None | False | 22785.0 | 0 |
2784629 | 88922 | None | code95 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: Pipes of SN4, 160mm dia. | m | 604.8 | 604.8 | 50.0 | False | None | None | False | None | False | 30240.0 | 0 |
2784630 | 88922 | None | code96 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: Pipes of SN4, 110mm dia. | m | 302.4 | 302.4 | 50.0 | False | None | None | False | None | False | 15120.0 | 0 |
2784631 | 88922 | None | code97 | Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. | Each | 4447.8 | 4447.8 | 1.0 | False | None | None | False | None | False | 4447.8 | 0 |
2784632 | 88922 | None | code98 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.. | Each | 5726.7 | 5726.7 | 1.0 | False | None | None | False | None | False | 5726.7 | 0 |
2784633 | 88922 | None | code99 | Providing and fixing 150mm dia. Cast Iron pipe for ventilatiing shaft 5 M high with specials and cowl and with suitable grips in CC 1:2:4 pillar using 10mm to 20mm graded hard granite, with 15 cms. thick cement concrete 1:2:4 around upto 1.22 M above the GLR and with a foundation base of 90 x 90 x 90 cms. plastered with 12mm thick CM 1:3 to all exposed faces and linking the shaft to the manholes by means of 150mm dia. GSW pipes and specials, jointing with tar dipped hemp 1:1.5 CM caulking, curing. The cost include all lead and lifts for all materials, earth work excavations and refilling in all strata, disposal of surplus earth etc. complete. | Each | 22141.35 | 22141.35 | 1.0 | False | None | None | False | None | False | 22141.35 | 0 |
2784634 | 88922 | None | code100 | Providing and constructing of Machinehole chambers conical in shape at top with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15m alround the chamber and brick masonry in C.M 1:4 plaster with bricks of approved quality and CM plaster 1:3 proportion 12mm thick inside and outside except for the conical surface outside where the thickness of plaster shall be 20 mm thick, with 1 to 6 slope in the concrete towards the central drain, finished smooth and fixing of pipes in CC 1:2:4 with graded metal of 20 mm and down size including supplying and fixing SFRC Machinehole frame and cover confoming to IS 12592(Part-I): 1988 & IS 12592(Part-II) :1991 with latest amendments in CC 1:2:4, supplying and fixing of plastic foot steps staggered at 30cms apart as directed, watering, curing,barricading, danger lighting, pouring tar over M.H. frame and cover, cost of tar, shoring, strutting, dewatering, engraving Machinehole No. on the inner and outer conical surface etc. as per the drawing with all lead and lift for various diameters and depths noted below. With Table Moulded Bricks & Medium Duty SFRC Cover & Frame: For 1.2m dia 40.1 T510A Constructing Table Moulded Bricks Machinehole 1.2 m internal dia. , 1.0 M depth & Medium duty SFRC cover & frame. | Each | 25566.45 | 25566.45 | 1.0 | False | None | None | False | None | False | 25566.45 | 0 |
2784635 | 88922 | None | code102 | TRUSSES - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & dowel bars to be paid separately) RCC Column M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Also include cost of formwork. | Cum | 11834.55 | 11834.55 | 2.12 | False | None | None | False | None | False | 25089.246 | 0 |
2784636 | 88922 | None | code103 | Providing Thermo-Mechanically Treated bars of grade Fe-500 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members wherever necessary complete as per Design including cost of material, labour, usage charges complete as per specifcations. (The laps and wastages shall not be measured separately) | Kg | 93.93 | 93.93 | 249.57 | False | None | None | False | None | False | 23442.1101 | 0 |
2784637 | 88922 | None | code104 | Providing 15 mm cement plaster of mix :1:4 (1 cement: 4 fne sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifcations and as per directions of Engineer-in-charge. | Sqm | 309.75 | 309.75 | 28.26 | False | None | None | False | None | False | 8753.535 | 0 |
2784638 | 88922 | None | code105 | Providing & fixing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge. 0.63 mm thick with zinc coating not less than 275 g/ m² | Sqm | 922.95 | 922.95 | 170.0 | False | None | None | False | None | False | 156901.5 | 0 |
2784639 | 88922 | None | code106 | Providing & fixing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete as per design drawings. 0.63 mm thick with zinc coating not less than 275 g/m² m | m | 670.95 | 670.95 | 17.0 | False | None | None | False | None | False | 11406.15 | 0 |
2784640 | 88922 | None | code107 | Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete. 0.63 mm thick with zinc coating not less than 275 g/ m² | m | 677.25 | 677.25 | 24.0 | False | None | None | False | None | False | 16254.0 | 0 |
2784641 | 88922 | None | code108 | Providing and fixing Structural Steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. 72 x72mm 3.2mm tk | Kg | 111.3 | 111.3 | 900.0 | False | None | None | False | None | False | 100170.0 | 0 |
2784642 | 88922 | None | code109 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifcations and as per directions of Engineer-in-charge. | Sqm | 145.95 | 145.95 | 57.6 | False | None | None | False | None | False | 8406.72 | 0 |
2784643 | 88922 | None | code110 | COMPOUND WALL : Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifcations, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. All kinds of soil 50% | Cum | 107.1 | 107.1 | 36.5 | False | None | None | False | None | False | 3909.15 | 0 |
2784644 | 88922 | None | code111 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifcations, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. Soft Rock 50% | Cum | 381.15 | 381.15 | 36.5 | False | None | None | False | None | False | 13911.975 | 0 |
2784645 | 88922 | None | code112 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 279.3 | 279.3 | 25.0 | False | None | None | False | None | False | 6982.5 | 0 |
2784646 | 88922 | None | code113 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & formwork shall be paid separately). Mix 1:4:8 (M5) Using 40 mm nominal size graded crushed coarse aggregates. | Cum | 5947.2 | 5947.2 | 4.32 | False | None | None | False | None | False | 25691.904 | 0 |
2784647 | 88922 | None | code114 | Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6515.25 | 6515.25 | 6.35 | False | None | None | False | None | False | 41371.8375 | 0 |
2784648 | 88922 | None | code115 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6708.45 | 6708.45 | 18.11 | False | None | None | False | None | False | 121490.0295 | 0 |
2784649 | 88922 | None | code116 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticizers laid in fnished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Also includes cost of formwork. | Cum | 7129.46 | 7129.46 | 2.7 | False | None | None | False | None | False | 19249.542 | 0 |
2784650 | 88922 | None | code117 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) RCC Column M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Also includes cost of formwork. | Cum | 11834.55 | 11834.55 | 3.17 | False | None | None | False | None | False | 37515.5235 | 0 |
2784651 | 88922 | None | code118 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & formwork to be paid separately) RCC Plinth Beam M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Also includes cost of formwork. | Cum | 9958.73 | 9958.73 | 3.17 | False | None | None | False | None | False | 31569.1741 | 0 |
2784652 | 88922 | None | code119 | Providing Thermo-Mechanically Treated bars of grade Fe-500 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members wherever necessary complete as per Design including cost of material, labour, usage charges complete as per specifcations. (The laps and wastages shall not be measured separately) | Kg | 93.93 | 93.93 | 781.27 | False | None | None | False | None | False | 73384.6911 | 0 |
2784653 | 88922 | None | code120 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifcations. | Sqm | 1375.5 | 1375.5 | 165.6 | False | None | None | False | None | False | 227782.8 | 0 |
2784654 | 88922 | None | code121 | Providing 15 mm cement plaster of mix :1:4 (1 cement: 4 fne sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifcations and as per directions of Engineer-in-charge. | Sqm | 309.75 | 309.75 | 338.11 | False | None | None | False | None | False | 104729.5725 | 0 |
2784655 | 88922 | None | code122 | Finishing walls with water proofng cement paint of required shade:Old work (one coats applied @ 2.20 kg/10 m²) over priming coat of primer applied @ 0.80 litrs/10 m² complete including cost of Priming coat including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifcations and as per directions of Engineer-in-charge. | Sqm | 91.35 | 91.35 | 338.11 | False | None | None | False | None | False | 30886.3485 | 0 |
2784656 | 88922 | None | code123 | Providing and fxing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. | Kg | 192.15 | 192.15 | 300.0 | False | None | None | False | None | False | 57645.0 | 0 |
2784657 | 88922 | None | code124 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifcations and as per directions of Engineer-in-charge. | Sqm | 145.95 | 145.95 | 6.0 | False | None | None | False | None | False | 875.7 | 0 |
2784658 | 88922 | None | code125 | DG Set :
3 Ph, 50 Hz, 415 V, 0.8 pf, 250 kVA capacity Diesel Generator set mounted on box frame complete with inbuilt fuel tank and battery 2 nos. 24 V and inbuilt standard manual control panel with acoustic enclosure : NAL approved D.G. set 250 kVA capacity with AMF panel as per technical specification | Nos | 1145124.75 | 1145124.75 | 1.0 | False | None | None | False | None | False | 1145124.75 | 0 |
2784659 | 88922 | None | code126 | Erection | Nos | 44322.6 | 44322.6 | 1.0 | False | None | None | False | None | False | 44322.6 | 0 |
2784660 | 88922 | None | code127 | PSC Pole - 8 Mtr Long, 200 Kg WL | Nos | 3883.95 | 3883.95 | 2.0 | False | None | None | False | None | False | 7767.9 | 0 |
2784661 | 88922 | None | code128 | Providing GI Pipe Earthling for Lightning Arrester, Transformer Neutral and Transformer Metal parts (Excluding digging of pits) | Set | 199.5 | 199.5 | 4.0 | False | None | None | False | None | False | 798.0 | 0 |
2784662 | 88922 | None | code129 | Lettering the RMU with enamel paint and also writing single line diagram of each panel, caution Board, Danger Board etc., including cost of Paint, Brush etc., | No | 1009.05 | 1009.05 | 2.0 | False | None | None | False | None | False | 2018.1 | 0 |
2784663 | 88922 | None | code130 | Anti - Climbing Device (12mtrs / 1 kg G.I. Barbed Wire) Lump sum | Kg | 93.45 | 93.45 | 5.0 | False | None | None | False | None | False | 467.25 | 0 |
2784664 | 88922 | None | code131 | INTERNAL WIRING & POWER POINTS - PVC CONDUIT AND ACCESSORIES - Concealed Conduit System:- Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. 19/20 mm dia 2 mm thick | m | 66.0 | 66.0 | 200.0 | False | None | None | False | None | False | 13200.0 | 0 |
2784665 | 88922 | None | code132 | Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. 25 mm dia 2 mm thick | m | 78.0 | 78.0 | 200.0 | False | None | None | False | None | False | 15600.0 | 0 |
2784666 | 88922 | None | code133 | Groove cutting. Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 19/20 mm dia 2 mm thick | m | 68.0 | 68.0 | 250.0 | False | None | None | False | None | False | 17000.0 | 0 |
2784667 | 88922 | None | code134 | Groove cutting. Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 25 mm dia 2 mm thick | m | 79.0 | 79.0 | 300.0 | False | None | None | False | None | False | 23700.0 | 0 |
2784668 | 88922 | None | code135 | Supplying and fixing PVC/ Metal Conduit Deep Junction Boxes. 19/20 mm deep Junction box | Each | 56.0 | 56.0 | 60.0 | False | None | None | False | None | False | 3360.0 | 0 |
2784669 | 88922 | None | code136 | Supplying and fixing PVC/ Metal Conduit Deep Junction Boxes. 25 mm deep Junction box | Each | 61.0 | 61.0 | 35.0 | False | None | None | False | None | False | 2135.0 | 0 |
2784670 | 88922 | None | code137 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm .... etc. as required. 20mm | m | 28.0 | 28.0 | 50.0 | False | None | None | False | None | False | 1400.0 | 0 |
2784671 | 88922 | None | code138 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm .... etc. as required. 25mm | m | 35.0 | 35.0 | 50.0 | False | None | None | False | None | False | 1750.0 | 0 |
2784672 | 88922 | None | code139 | Supplying PVC/GI flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely. 20mm | m | 19.0 | 19.0 | 50.0 | False | None | None | False | None | False | 950.0 | 0 |
2784673 | 88922 | None | code140 | Supplying PVC/GI flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely. 25mm | m | 22.0 | 22.0 | 40.0 | False | None | None | False | None | False | 880.0 | 0 |
2784674 | 88922 | None | code141 | Supplying and Fixing Metal Fan Box with Round Hook. | No | 117.0 | 117.0 | 18.0 | False | None | None | False | None | False | 2106.0 | 0 |
2784675 | 88922 | None | code142 | WIRES AND CABLES - Point wiring using copper wire without Switch :- Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm 2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.. Short point upto 3m from tapping point to out let via switch box | Point | 269.0 | 269.0 | 25.0 | False | None | None | False | None | False | 6725.0 | 0 |
2784676 | 88922 | None | code143 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm 2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.. Medium point above 3m upto 6m from tapping point to out let via switch box | Point | 379.0 | 379.0 | 35.0 | False | None | None | False | None | False | 13265.0 | 0 |
2784677 | 88922 | None | code144 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm 2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.. Long point above 6m upto 10m from tapping point to out let via switch box | Point | 555.0 | 555.0 | 20.0 | False | None | None | False | None | False | 11100.0 | 0 |
2784678 | 88922 | None | code145 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2 | m | 26.0 | 26.0 | 700.0 | False | None | None | False | None | False | 18200.0 | 0 |
2784679 | 88922 | None | code146 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2 | m | 42.0 | 42.0 | 1000.0 | False | None | None | False | None | False | 42000.0 | 0 |
2784680 | 88922 | None | code147 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 mm2 | m | 63.0 | 63.0 | 250.0 | False | None | None | False | None | False | 15750.0 | 0 |
2784681 | 88922 | None | code148 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 mm2 | m | 92.0 | 92.0 | 100.0 | False | None | None | False | None | False | 9200.0 | 0 |
2784682 | 88922 | None | code149 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 10 mm2 | m | 167.0 | 167.0 | 60.0 | False | None | None | False | None | False | 10020.0 | 0 |
2784683 | 88922 | None | code150 | SWITCHES, SOCKETS & ACCESSORIES - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 1-3 Way | Each | 138.0 | 138.0 | 5.0 | False | None | None | False | None | False | 690.0 | 0 |
2784684 | 88922 | None | code151 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 4-5 Way | Each | 177.0 | 177.0 | 10.0 | False | None | None | False | None | False | 1770.0 | 0 |
2784685 | 88922 | None | code152 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 6 Way | Each | 220.0 | 220.0 | 5.0 | False | None | None | False | None | False | 1100.0 | 0 |
2784686 | 88922 | None | code153 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 8 Way | Each | 261.0 | 261.0 | 5.0 | False | None | None | False | None | False | 1305.0 | 0 |
2784687 | 88922 | None | code154 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 12 Way | Each | 319.0 | 319.0 | 6.0 | False | None | None | False | None | False | 1914.0 | 0 |
2784688 | 88922 | None | code155 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 3 Module | Each | 137.0 | 137.0 | 20.0 | False | None | None | False | None | False | 2740.0 | 0 |
2784689 | 88922 | None | code156 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module | Each | 175.0 | 175.0 | 10.0 | False | None | None | False | None | False | 1750.0 | 0 |
2784690 | 88922 | None | code157 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module | Each | 234.0 | 234.0 | 30.0 | False | None | None | False | None | False | 7020.0 | 0 |
2784691 | 88922 | None | code158 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module | Each | 284.0 | 284.0 | 10.0 | False | None | None | False | None | False | 2840.0 | 0 |
2784692 | 88922 | None | code159 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module | Each | 344.0 | 344.0 | 8.0 | False | None | None | False | None | False | 2752.0 | 0 |
2784693 | 88922 | None | code160 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch | Each | 102.0 | 102.0 | 120.0 | False | None | None | False | None | False | 12240.0 | 0 |
2784694 | 88922 | None | code161 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Two Way Switch | Each | 166.0 | 166.0 | 3.0 | False | None | None | False | None | False | 498.0 | 0 |
2784695 | 88922 | None | code162 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Three Way socket | Each | 171.0 | 171.0 | 60.0 | False | None | None | False | None | False | 10260.0 | 0 |
2784696 | 88922 | None | code163 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two Module | Each | 357.0 | 357.0 | 15.0 | False | None | None | False | None | False | 5355.0 | 0 |
2784697 | 88922 | None | code164 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16A One Way Switch | Each | 180.0 | 180.0 | 15.0 | False | None | None | False | None | False | 2700.0 | 0 |
2784698 | 88922 | None | code165 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16A Universal Socket | Each | 236.0 | 236.0 | 8.0 | False | None | None | False | None | False | 1888.0 | 0 |
2784699 | 88922 | None | code166 | LUMINARIES & LIGHT FIXTURES & ACCESSORIES - Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2' - 9/10 W | Each | 551.0 | 551.0 | 10.0 | False | None | None | False | None | False | 5510.0 | 0 |
2784700 | 88922 | None | code167 | Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 W | Each | 690.0 | 690.0 | 20.0 | False | None | None | False | None | False | 13800.0 | 0 |
2784701 | 88922 | None | code168 | Supplying & fixing of retrofit type - LED bulb 7W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. | Each | 149.0 | 149.0 | 10.0 | False | None | None | False | None | False | 1490.0 | 0 |
2784702 | 88922 | None | code169 | Supply of round/square recess/surface mounted rolling type LED Down light with 10-12 W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition | Each | 885.0 | 885.0 | 3.0 | False | None | None | False | None | False | 2655.0 | 0 |
2784703 | 88922 | None | code170 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with 25W System Power consumption. LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned | Each | 2425.0 | 2425.0 | 4.0 | False | None | None | False | None | False | 9700.0 | 0 |
2784704 | 88922 | None | code171 | PANEL & DISTRIBUTION BOARDS - PANELS :- Fabricating supplying and mounting MS box made out 14 SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. | Sq CM | 0.5 | 0.5 | 6000.0 | False | None | None | False | None | False | 3000.0 | 0 |
2784705 | 88922 | None | code172 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 16 mm2 | m | 318.0 | 318.0 | 6.0 | False | None | None | False | None | False | 1908.0 | 0 |
2784706 | 88922 | None | code173 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. | Each | 515.0 | 515.0 | 3.0 | False | None | None | False | None | False | 1545.0 | 0 |
2784707 | 88922 | None | code174 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy. | Each | 9315.0 | 9315.0 | 1.0 | False | None | None | False | None | False | 9315.0 | 0 |
2784708 | 88922 | None | code175 | Supply and fixing of Auxiliary contactor relay with 2 NO and 2 NC contact and operating coil voltage of 220V to 260V. fixed on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., | Each | 1330.0 | 1330.0 | 1.0 | False | None | None | False | None | False | 1330.0 | 0 |
2784709 | 88922 | None | code176 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPN | Each | 3088.0 | 3088.0 | 1.0 | False | None | None | False | None | False | 3088.0 | 0 |
2784710 | 88922 | None | code177 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A TPN | Each | 1717.0 | 1717.0 | 1.0 | False | None | None | False | None | False | 1717.0 | 0 |
2784711 | 88922 | None | code178 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A DP | Each | 739.0 | 739.0 | 1.0 | False | None | None | False | None | False | 739.0 | 0 |
2784712 | 88922 | None | code179 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 50 x 50 x 6 mm | m | 395.0 | 395.0 | 1.0 | False | None | None | False | None | False | 395.0 | 0 |
2784713 | 88922 | None | code180 | DISTRIBUTION BOARDS - Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. Double Door 8 way SP & N | Each | 1854.0 | 1854.0 | 1.0 | False | None | None | False | None | False | 1854.0 | 0 |
2784714 | 88922 | None | code181 | DISTRIBUTION BOARDS - Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. Double Door 8 way TP & N | Each | 6091.0 | 6091.0 | 1.0 | False | None | None | False | None | False | 6091.0 | 0 |
2784715 | 88922 | None | code182 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker (ELMCB) 240/450V upto 300mA sensitivity on existing wood/panel board. 16 - 25 Amps 2 pole | Each | 4277.0 | 4277.0 | 2.0 | False | None | None | False | None | False | 8554.0 | 0 |
2784716 | 88922 | None | code183 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker (ELMCB) 240/450V upto 300mA sensitivity on existing wood/panel board. 32 - 40 Amps 2 pole | Each | 4559.0 | 4559.0 | 2.0 | False | None | None | False | None | False | 9118.0 | 0 |
2784717 | 88922 | None | code184 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker (ELMCB) 240/450V upto 300mA sensitivity on existing wood/panel board. 32 - 40 Amps 4 pole | Each | 5147.0 | 5147.0 | 2.0 | False | None | None | False | None | False | 10294.0 | 0 |
2784718 | 88922 | None | code185 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6 - 32 Amp SP | Each | 415.0 | 415.0 | 5.0 | False | None | None | False | None | False | 2075.0 | 0 |
2784719 | 88922 | None | code186 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50 - 63 Amp SP | Each | 811.0 | 811.0 | 2.0 | False | None | None | False | None | False | 1622.0 | 0 |
2784720 | 88922 | None | code187 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6 - 32 Amp DP | Each | 739.0 | 739.0 | 1.0 | False | None | None | False | None | False | 739.0 | 0 |
2784721 | 88922 | None | code188 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50 - 63 Amp TPN | Each | 3088.0 | 3088.0 | 1.0 | False | None | None | False | None | False | 3088.0 | 0 |
2784722 | 88922 | None | code189 | SERVICE MAINS & WORK UNDER UG CABLE, EARTHING - Supplying Fixing and Wiring earth electrode for grounding of lifts, Xmen, DG Sets etsc using 40mm dia 2.9mm thivk, 2.5mts long GI pipe eith GI funnel with mesh &suitable size reducer fixed on the top of electrode. The funnel should be enclosed in a cc chamber of 400*400*400 with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia & electrode should be coverd 150mm around with alternatye layers of salt & charcoal from the bottem of the CC Chamber. The connection from the electrode is to be established through GI strip using GI bolts & nuts. | Each | 4150.0 | 4150.0 | 1.0 | False | None | None | False | None | False | 4150.0 | 0 |
2784723 | 88922 | None | code190 | Supplying & running of GI / Cu. Strips for grounding connections using necessary fixing materials as required. GI Strip, 25*3 mm GI strips | Mtr | 75.0 | 75.0 | 10.0 | False | None | None | False | None | False | 750.0 | 0 |
2784724 | 88922 | None | code191 | Supplying & running of GI / Cu. Strips for grounding connections using necessary fixing materials as required. GI Strip, 25*3 mm GI strips | Each | 760.0 | 760.0 | 2.0 | False | None | None | False | None | False | 1520.0 | 0 |
2784725 | 88922 | None | code192 | Supplying & running of GI / Cu. Strips for grounding connections using necessary fixing materials as required. Cu. Strip 25*3 mm | Mtr | 505.0 | 505.0 | 2.0 | False | None | None | False | None | False | 1010.0 | 0 |
2784726 | 88922 | None | code193 | Supplying & running of GI / Cu. Strips for grounding connections using necessary fixing materials as required. Cu. Strip 600*600*3 Cu. Plate | Each | 6900.0 | 6900.0 | 1.0 | False | None | None | False | None | False | 6900.0 | 0 |
2784727 | 88922 | None | code194 | Supplying & running of GI / Cu. Strips for grounding connections using necessary fixing materials as required. GI wire, 12 SWG GI wire | Mtr | 14.0 | 14.0 | 20.0 | False | None | None | False | None | False | 280.0 | 0 |
2784728 | 88922 | None | code195 | Supplying & running of GI / Cu. Strips for grounding connections using necessary fixing materials as required. Cu. Wire 12 SWG | Mtr | 58.0 | 58.0 | 50.0 | False | None | None | False | None | False | 2900.0 | 0 |
2784729 | 88922 | None | code196 | 10 SWG | Mtr | 68.0 | 68.0 | 50.0 | False | None | None | False | None | False | 3400.0 | 0 |
2784730 | 88922 | None | code197 | 2C*10sq.m.m.Alum.Cable | Mtr | 95.0 | 95.0 | 20.0 | False | None | None | False | None | False | 1900.0 | 0 |
2784731 | 88922 | None | code198 | 4C*10sq.m.m.Alum.Cable | Mtr | 130.0 | 130.0 | 15.0 | False | None | None | False | None | False | 1950.0 | 0 |
2784732 | 88922 | None | code199 | 4C*16sq.m.m.Alum.Cable | Mtr | 150.0 | 150.0 | 15.0 | False | None | None | False | None | False | 2250.0 | 0 |
2784733 | 88922 | None | code200 | Supply & Fixing of Heavy Duty cable glands suitable for UG Cable of 1.1KV Class (metal only) 25mm dia | Nos | 84.0 | 84.0 | 2.0 | False | None | None | False | None | False | 168.0 | 0 |
2784734 | 88922 | None | code201 | Supplying Tinned copper Lugs & crimping and wiring to terminal point for wire of following sizes. 16sqmm long Barrel | Nos | 13.0 | 13.0 | 2.0 | False | None | None | False | None | False | 26.0 | 0 |
2784735 | 88922 | None | code202 | FANS - Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty. 48"Sweep 5 Star (1200mm) | Each | 2677.0 | 2677.0 | 20.0 | False | None | None | False | None | False | 53540.0 | 0 |
2784736 | 88922 | None | code203 | Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. | Each | 1492.0 | 1492.0 | 2.0 | False | None | None | False | None | False | 2984.0 | 0 |
2784737 | 88922 | None | code204 | UPS & BATTERIES - Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 5 kVA ON LINE UPS | Each | 79172.0 | 79172.0 | 1.0 | False | None | None | False | None | False | 79172.0 | 0 |
2784738 | 88922 | None | code205 | Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 120 AH capacity | Each | 15783.0 | 15783.0 | 4.0 | False | None | None | False | None | False | 63132.0 | 0 |