tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1707118939000 | 0 | None | None | Buildings | Construction of Market Building at Sy.No 290/1B1, Herga Village, Parkala ward in Udupi CMC Limit, Udupi Taluk and District.(BUILDING WORK) | 25307791.92 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2439854 | 73427 | None | code01 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.-By Mechanical Means using Dozer-In area of thorny jungle | ha | 188816.32 | 188816.32 | 0.22 | False | None | None | False | None | False | 41539.5904 | 0 | 2439855 | 73427 | None | code02 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work-In all kinds of soils Depth upto 3 m | Cum | 81.76 | 81.76 | 1777.18 | False | None | None | False | None | False | 145302.2368 | 0 | 2439856 | 73427 | None | code03 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work- In ordinary/soft rock without blasting- Depth exceeding 3m, but not exceeding 4.5m | Cum | 390.88 | 390.88 | 1184.79 | False | None | None | False | None | False | 463110.7152 | 0 | 2439857 | 73427 | None | code04 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/Sqm including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications | Sqm | 106.4 | 106.4 | 680.5 | False | None | None | False | None | False | 72405.2 | 0 | 2439858 | 73427 | None | code05 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse | Cum | 5830.72 | 5830.72 | 48.97 | False | None | None | False | None | False | 285530.3584 | 0 | 2439859 | 73427 | None | code06 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)-SQM5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7232.2 | 7232.2 | 138.24 | False | None | None | False | None | False | 999779.328 | 0 | 2439860 | 73427 | None | code07 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)-SQM5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7232.2 | 7232.2 | 11.88 | False | None | None | False | None | False | 85918.536 | 0 | 2439861 | 73427 | None | code08 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--SQM5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 10392.48 | 10392.48 | 15.14 | False | None | None | False | None | False | 157342.1472 | 0 | 2439862 | 73427 | None | code09 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other---- M30 Design Mix Using 20 mm nominal size graded crushed coarse | Cum | 7382.14 | 7382.14 | 156.78 | False | None | None | False | None | False | 1157371.9092 | 0 | 2439863 | 73427 | None | code10 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 228.48 | 228.48 | 956.06 | False | None | None | False | None | False | 218440.5888 | 0 | 2439864 | 73427 | None | code11 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 450.24 | 450.24 | 172.89 | False | None | None | False | None | False | 77841.9936 | 0 | 2439865 | 73427 | None | code12 | providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5994.24 | 5994.24 | 12.78 | False | None | None | False | None | False | 76606.3872 | 0 | 2439866 | 73427 | None | code13 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse | Cum | 6415.36 | 6415.36 | 0.96 | False | None | None | False | None | False | 6158.7456 | 0 | 2439867 | 73427 | None | code14 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--SQM5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11778.14 | 11778.14 | 13.35 | False | None | None | False | None | False | 157238.169 | 0 | 2439868 | 73427 | None | code15 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--SQM5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11895.93 | 11895.93 | 13.35 | False | None | None | False | None | False | 158810.6655 | 0 | 2439869 | 73427 | None | code16 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--SQM5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FIRST FLOOR | Cum | 12013.71 | 12013.71 | 1.24 | False | None | None | False | None | False | 14897.0004 | 0 | 2439870 | 73427 | None | code17 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11342.36 | 11342.36 | 4.04 | False | None | None | False | None | False | 45823.1344 | 0 | 2439871 | 73427 | None | code18 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)-- M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11085.31 | 11085.31 | 24.63 | False | None | None | False | None | False | 273031.1853 | 0 | 2439872 | 73427 | None | code19 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)-- M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11196.17 | 11196.17 | 24.63 | False | None | None | False | None | False | 275761.6671 | 0 | 2439873 | 73427 | None | code20 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)-- M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 12241.04 | 12241.04 | 2.14 | False | None | None | False | None | False | 26195.8256 | 0 | 2439874 | 73427 | None | code21 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)-- M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11085.31 | 11085.31 | 0.66 | False | None | None | False | None | False | 7316.3046 | 0 | 2439875 | 73427 | None | code22 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)-- M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11196.17 | 11196.17 | 7.97 | False | None | None | False | None | False | 89233.4749 | 0 | 2439876 | 73427 | None | code23 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)-- M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11307.02 | 11307.02 | 0.66 | False | None | None | False | None | False | 7462.6332 | 0 | 2439877 | 73427 | None | code24 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse | Cum | 10264.58 | 10264.58 | 0.33 | False | None | None | False | None | False | 3387.3114 | 0 | 2439878 | 73427 | None | code25 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse | Cum | 10367.22 | 10367.22 | 2.84 | False | None | None | False | None | False | 29442.9048 | 0 | 2439879 | 73427 | None | code26 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse | Cum | 10469.87 | 10469.87 | 0.33 | False | None | None | False | None | False | 3455.0571 | 0 | 2439880 | 73427 | None | code27 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)-- M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (BASEMENT FLOOR | Cum | 10392.48 | 10392.48 | 18.0 | False | None | None | False | None | False | 187064.64 | 0 | 2439881 | 73427 | None | code28 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)-- M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (GROUND FLOOR | Cum | 10496.4 | 10496.4 | 4.29 | False | None | None | False | None | False | 45029.556 | 0 | 2439882 | 73427 | None | code29 | Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification. I.S 3620/1979 having compressive strength not less than 3.5 N/mSqm for saturated dry samples-For super structure in CM 1:6. ITEM-6.37, volume-2, (1st addenda for vol.1,2 & 3 schedule of rates w.e.f 21-04-2022.) BASEMENT FLOOR | Cum | 6611.36 | 6611.36 | 8.57 | False | None | None | False | None | False | 56659.3552 | 0 | 2439883 | 73427 | None | code30 | Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification. I.S 3620/1979 having compressive strength not less than 3.5 N/mSqm for saturated dry samples-For super structure in CM 1:6. ITEM-6.37, volume-2, (1st addenda for vol.1,2 & 3 schedule of rates w.e.f 21-04-2022.) GROUND FLOOR | Cum | 6677.47 | 6677.47 | 104.91 | False | None | None | False | None | False | 700533.3777 | 0 | 2439884 | 73427 | None | code31 | Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification. I.S 3620/1979 having compressive strength not less than 3.5 N/mSqm for saturated dry samples-For super structure in CM 1:6. ITEM-6.37, volume-2, (1st addenda for vol.1,2 & 3 schedule of rates w.e.f 21-04-2022.) HEAD ROOM | Cum | 6743.59 | 6743.59 | 8.44 | False | None | None | False | None | False | 56915.8996 | 0 | 2439885 | 73427 | None | code32 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mSqm conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications GROUND FLOOR | Sqm | 1339.52 | 1339.52 | 36.66 | False | None | None | False | None | False | 49106.8032 | 0 | 2439886 | 73427 | None | code33 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mSqm conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. BASEMENT FLOOR | Sqm | 1188.32 | 1188.32 | 65.43 | False | None | None | False | None | False | 77751.7776 | 0 | 2439887 | 73427 | None | code34 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mSqm conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. GROUND FLOOR | Sqm | 1200.2 | 1200.2 | 120.43 | False | None | None | False | None | False | 144540.086 | 0 | 2439888 | 73427 | None | code35 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mSqm conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. SECOND FLOOR | Sqm | 1212.09 | 1212.09 | 118.56 | False | None | None | False | None | False | 143705.3904 | 0 | 2439889 | 73427 | None | code36 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mSqm conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. BASEMENT FLOOR | Sqm | 1052.8 | 1052.8 | 8.4 | False | None | None | False | None | False | 8843.52 | 0 | 2439890 | 73427 | None | code37 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mSqm conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. GROUND FLOOR | Sqm | 1063.33 | 1063.33 | 48.72 | False | None | None | False | None | False | 51805.4376 | 0 | 2439891 | 73427 | None | code38 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)-- M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) BASEMENT FLOOR | Cum | 10392.48 | 10392.48 | 67.88 | False | None | None | False | None | False | 705441.5424 | 0 | 2439892 | 73427 | None | code39 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)-- M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) GROUND FLOOR | Cum | 10496.4 | 10496.4 | 67.88 | False | None | None | False | None | False | 712495.632 | 0 | 2439893 | 73427 | None | code40 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)-- M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) TERRACE FLOOR | Cum | 10600.33 | 10600.33 | 2.25 | False | None | None | False | None | False | 23850.7425 | 0 | 2439894 | 73427 | None | code41 | Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | Kg | 103.04 | 103.04 | 37020.13 | False | None | None | False | None | False | 3814554.1952 | 0 | 2439895 | 73427 | None | code42 | Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)BASEMENT FLOOR | Kg | 103.04 | 103.04 | 19990.83 | False | None | None | False | None | False | 2059855.1232 | 0 | 2439896 | 73427 | None | code43 | Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) GROUND FLOOR | Kg | 104.07 | 104.07 | 19100.4 | False | None | None | False | None | False | 1987778.628 | 0 | 2439897 | 73427 | None | code45 | Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. GROUND FLOOR | Cum | 69685.31 | 69685.31 | 0.18 | False | None | None | False | None | False | 12543.3558 | 0 | 2439898 | 73427 | None | code46 | Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. TERRACE FLOOR | Cum | 70375.27 | 70375.27 | 0.09 | False | None | None | False | None | False | 6333.7743 | 0 | 2439899 | 73427 | None | code48 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door frames of cross section 90mmx 45mm having single rebate of 32mm x 15mm to recive shutter of 30mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyster resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S stay shall be provided at the bottom to steady the frame. GROUND FLOOR | Rmtr | 713.79 | 713.79 | 25.6 | False | None | None | False | None | False | 18273.024 | 0 | 2439900 | 73427 | None | code49 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. BASEMENT FLOOR | Sqm | 2811.2 | 2811.2 | 15.0 | False | None | None | False | None | False | 42168.0 | 0 | 2439901 | 73427 | None | code50 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.GROUND FLOOR | Sqm | 2839.31 | 2839.31 | 126.75 | False | None | None | False | None | False | 359882.5425 | 0 | 2439902 | 73427 | None | code51 | Extra for providing mechanical device chain and crank operation for operating rolling shutters: Exceeding 10.00 m² and upto 16.80 m² in the area including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineerin-Charge. BASEMENT FLOOR | Sqm | 1105.44 | 1105.44 | 15.0 | False | None | None | False | None | False | 16581.6 | 0 | 2439903 | 73427 | None | code52 | Extra for providing mechanical device chain and crank operation for operating rolling shutters: Exceeding 10.00 m² and upto 16.80 m² in the area including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineerin-ChargeGROUND FLOOR | Sqm | 1116.49 | 1116.49 | 126.75 | False | None | None | False | None | False | 141515.1075 | 0 | 2439904 | 73427 | None | code53 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. BASEMENT FLOOR | Sqm | 7350.56 | 7350.56 | 12.5 | False | None | None | False | None | False | 91882.0 | 0 | 2439905 | 73427 | None | code54 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. GROUND FLOOR | Sqm | 7424.07 | 7424.07 | 15.0 | False | None | None | False | None | False | 111361.05 | 0 | 2439906 | 73427 | None | code55 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 8108.8 | 8108.8 | 1.82 | False | None | None | False | None | False | 14758.016 | 0 | 2439907 | 73427 | None | code56 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having a overall size of 60mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm X 58mm with GI reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2-2.5 mm. Maximum possible size 1819mm x 1819mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOOR | Sqm | 7180.32 | 7180.32 | 1.0 | False | None | None | False | None | False | 7180.32 | 0 | 2439908 | 73427 | None | code57 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having a overall size of 60mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm X 58mm with GI reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2-2.5 mm. Maximum possible size 1819mm x 1819mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) FIRST FLOOR | Sqm | 7252.12 | 7252.12 | 2.16 | False | None | None | False | None | False | 15664.5792 | 0 | 2439909 | 73427 | None | code58 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) BASEMENT FLOOR | Sqm | 5454.4 | 5454.4 | 0.18 | False | None | None | False | None | False | 981.792 | 0 | 2439910 | 73427 | None | code59 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)GROUND FLOOR | Sqm | 5508.94 | 5508.94 | 30.67 | False | None | None | False | None | False | 168959.1898 | 0 | 2439911 | 73427 | None | code61 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-35 mm thick one side teak and one side commercial GROUND FLOOR | Sqm | 3896.98 | 3896.98 | 5.16 | False | None | None | False | None | False | 20108.4168 | 0 | 2439912 | 73427 | None | code62 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-35 mm thick one side teak and one side commercial FIRST FLOOR | Sqm | 3935.57 | 3935.57 | 2.58 | False | None | None | False | None | False | 10153.7706 | 0 | 2439913 | 73427 | None | code64 | Providing and fixing to existing door frames. 30mm thick Glass fiber reinforced plastic (FRP) pannelled door shutter of requirred colour and approved brand and manufacture, made with fre-retardant grade unsaturated polyster resin, moulded to 3mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5mm thick FRP laminate for panels confirming to IS: 14856, including fixing to frames. GROUND FLOOR | Sqm | 3535.0 | 3535.0 | 6.45 | False | None | None | False | None | False | 22800.75 | 0 | 2439914 | 73427 | None | code65 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding BASEMENT FLOOR | Kg | 162.4 | 162.4 | 32.04 | False | None | None | False | None | False | 5203.296 | 0 | 2439915 | 73427 | None | code66 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding GROUND FLOOR | Kg | 164.02 | 164.02 | 820.8 | False | None | None | False | None | False | 134627.616 | 0 | 2439916 | 73427 | None | code67 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. GROUND & FIRST FLOOR | No | 1658.72 | 1658.72 | 1.0 | False | None | None | False | None | False | 1658.72 | 0 | 2439917 | 73427 | None | code68 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. | No | 122.08 | 122.08 | 2.0 | False | None | None | False | None | False | 244.16 | 0 | 2439918 | 73427 | None | code69 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete. | No. | 196.0 | 196.0 | 4.0 | False | None | None | False | None | False | 784.0 | 0 | 2439919 | 73427 | None | code70 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10mm, | Each | 377.44 | 377.44 | 4.0 | False | None | None | False | None | False | 1509.76 | 0 | 2439920 | 73427 | None | code71 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete 125x85x5.5mm.(heavy type) | No. | 225.12 | 225.12 | 10.0 | False | None | None | False | None | False | 2251.2 | 0 | 2439921 | 73427 | None | code72 | Providing and fixing MS Hold fasts | Each | 35.84 | 35.84 | 12.0 | False | None | None | False | None | False | 430.08 | 0 | 2439922 | 73427 | None | code73 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms. | No | 52.64 | 52.64 | 2.0 | False | None | None | False | None | False | 105.28 | 0 | 2439923 | 73427 | None | code74 | Providing 12 mm cement plaster with Cement mortar 1:3 (1cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete BASEMENT FLOOR | Sqm | 306.88 | 306.88 | 945.04 | False | None | None | False | None | False | 290013.8752 | 0 | 2439924 | 73427 | None | code75 | Providing 12 mm cement plaster with Cement mortar 1:3 (1cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete GROUND FLOOR | Sqm | 309.95 | 309.95 | 705.45 | False | None | None | False | None | False | 218654.2275 | 0 | 2439925 | 73427 | None | code76 | Providing 12 mm cement plaster with Cement mortar 1:3 (1cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete TERRACE FLOOR | Sqm | 313.02 | 313.02 | 24.0 | False | None | None | False | None | False | 7512.48 | 0 | 2439926 | 73427 | None | code77 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. BASEMENT FLOOR | Sqm | 348.32 | 348.32 | 664.98 | False | None | None | False | None | False | 231625.8336 | 0 | 2439927 | 73427 | None | code78 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 351.8 | 351.8 | 1281.4 | False | None | None | False | None | False | 450796.52 | 0 | 2439928 | 73427 | None | code79 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. FIRST FLOOR | Sqm | 355.29 | 355.29 | 62.7 | False | None | None | False | None | False | 22276.683 | 0 | 2439929 | 73427 | None | code80 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. BASEMENT FLOOR | Sqm | 277.76 | 277.76 | 1.0 | False | None | None | False | None | False | 277.76 | 0 | 2439930 | 73427 | None | code81 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 280.54 | 280.54 | 203.64 | False | None | None | False | None | False | 57129.1656 | 0 | 2439931 | 73427 | None | code82 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. BASEMENT FLOOR | Sqm | 360.64 | 360.64 | 225.4 | False | None | None | False | None | False | 81288.256 | 0 | 2439932 | 73427 | None | code83 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 364.25 | 364.25 | 359.8 | False | None | None | False | None | False | 131057.15 | 0 | 2439933 | 73427 | None | code84 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR | Sqm | 367.85 | 367.85 | 269.85 | False | None | None | False | None | False | 99264.3225 | 0 | 2439934 | 73427 | None | code85 | Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineerin-Charge. BASEMENT FLOOR | Kg | 57.12 | 57.12 | 338.1 | False | None | None | False | None | False | 19312.272 | 0 | 2439935 | 73427 | None | code86 | Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineerin-Charge. GROUND FLOOR | Kg | 57.69 | 57.69 | 179.9 | False | None | None | False | None | False | 10378.431 | 0 | 2439936 | 73427 | None | code87 | Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineerin-Charge. FIRST FLOOR | Kg | 58.26 | 58.26 | 134.93 | False | None | None | False | None | False | 7861.0218 | 0 | 2439937 | 73427 | None | code88 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse | Cum | 6415.36 | 6415.36 | 88.0 | False | None | None | False | None | False | 564551.68 | 0 | 2439938 | 73427 | None | code89 | Construction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3 , coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing BASEMENT FLOOR | Cum | 10040.8 | 10040.8 | 98.4 | False | None | None | False | None | False | 988014.72 | 0 | 2439939 | 73427 | None | code90 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per Sqm to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per Sqm and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. TERRACE FLOOR | Sqm | 867.78 | 867.78 | 576.0 | False | None | None | False | None | False | 499841.28 | 0 | 2439940 | 73427 | None | code91 | Providing 12 mm cement plaster with Cement mortar 1:3 (1cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete TERRACE FLOOR | Sqm | 319.16 | 319.16 | 576.0 | False | None | None | False | None | False | 183836.16 | 0 | 2439941 | 73427 | None | code92 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per Sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. | Sqm | 653.86 | 653.86 | 332.08 | False | None | None | False | None | False | 217133.8288 | 0 | 2439942 | 73427 | None | code93 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per Sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top co | Sqm | 428.06 | 428.06 | 16.53 | False | None | None | False | None | False | 7075.8318 | 0 | 2439943 | 73427 | None | code94 | Gutter (600 mm over all girth) | Rmtr | 1005.48 | 1005.48 | 55.1 | False | None | None | False | None | False | 55401.948 | 0 | 2439944 | 73427 | None | code96 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 159.94 | 159.94 | 1992.49 | False | None | None | False | None | False | 318678.8506 | 0 | 2439945 | 73427 | None | code97 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. BASEMENT FLOOR | Sqm | 3214.4 | 3214.4 | 355.98 | False | None | None | False | None | False | 1144262.112 | 0 | 2439946 | 73427 | None | code98 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. GROUND FLOOR | Sqm | 3246.54 | 3246.54 | 256.61 | False | None | None | False | None | False | 833094.6294 | 0 | 2439947 | 73427 | None | code99 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ Sqm including grouting the joints with white cement and matching pigments etc., complete.-- Size of Tile 800x800 mm BASEMENT FLOOR | Sqm | 1554.56 | 1554.56 | 19.16 | False | None | None | False | None | False | 29785.3696 | 0 | 2439948 | 73427 | None | code100 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ Sqm including grouting the joints with white cement and matching pigments etc., complete.-- Size of Tile 800x800 mm GROUND FLOOR | Sqm | 1570.11 | 1570.11 | 202.87 | False | None | None | False | None | False | 318528.2157 | 0 | 2439949 | 73427 | None | code101 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ Sqm including grouting the joints with white cement and matching pigments etc., complete.-- Size of Tile 800x800 mmTERRACE FLOOR | Sqm | 1585.65 | 1585.65 | 10.2 | False | None | None | False | None | False | 16173.63 | 0 | 2439950 | 73427 | None | code102 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ Sqm including pointing the joints with white cement and matching pigments etc., complete BASEMENT FLOOR | Sqm | 853.44 | 853.44 | 3.75 | False | None | None | False | None | False | 3200.4 | 0 | 2439951 | 73427 | None | code103 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ Sqm including pointing the joints with white cement and matching pigments etc., complete GROUND FLOOR | Sqm | 861.97 | 861.97 | 130.06 | False | None | None | False | None | False | 112107.8182 | 0 | 2439952 | 73427 | None | code104 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per Sqm, including pointing in white cement mixed with pigment of matching shade complete. BASEMENT FLOOR | Sqm | 1079.68 | 1079.68 | 2.25 | False | None | None | False | None | False | 2429.28 | 0 | 2439953 | 73427 | None | code105 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per Sqm, including pointing in white cement mixed with pigment of matching shade complete. GOUND FLOOR | Sqm | 1090.48 | 1090.48 | 155.12 | False | None | None | False | None | False | 169155.2576 | 0 | 2439954 | 73427 | None | code106 | Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications BASEMENT FLOOR | Sqm | 1382.08 | 1382.08 | 5.13 | False | None | None | False | None | False | 7090.0704 | 0 | 2439955 | 73427 | None | code107 | Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications GROUND FLOOR | Sqm | 1395.9 | 1395.9 | 2.57 | False | None | None | False | None | False | 3587.463 | 0 | 2439956 | 73427 | None | code108 | Providing and laying flooring and steps machine cut granite slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar labour, curing complete as per specifications. BASEMENT FLOOR | Sqm | 2647.68 | 2647.68 | 1.2 | False | None | None | False | None | False | 3177.216 | 0 | 2439957 | 73427 | None | code109 | Providing and laying flooring and steps machine cut granite slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar labour, curing complete as per specifications. GROUND FLOOR | Sqm | 2674.16 | 2674.16 | 2.4 | False | None | None | False | None | False | 6417.984 | 0 | 2439958 | 73427 | None | code110 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. BASEMENT FLOOR | Sqm | 92.96 | 92.96 | 1610.02 | False | None | None | False | None | False | 149667.4592 | 0 | 2439959 | 73427 | None | code111 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. GROUND FLOOR | Sqm | 93.89 | 93.89 | 1986.85 | False | None | None | False | None | False | 186545.3465 | 0 | 2439960 | 73427 | None | code112 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. TERRACE FLOOR | Sqm | 94.82 | 94.82 | 86.7 | False | None | None | False | None | False | 8220.894 | 0 | 2439961 | 73427 | None | code113 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. BASEMENT FLOOR | Sqm | 132.16 | 132.16 | 945.04 | False | None | None | False | None | False | 124896.4864 | 0 | 2439962 | 73427 | None | code114 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 133.48 | 133.48 | 705.45 | False | None | None | False | None | False | 94163.466 | 0 | 2439963 | 73427 | None | code115 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOOR | Sqm | 134.8 | 134.8 | 24.0 | False | None | None | False | None | False | 3235.2 | 0 | 2439964 | 73427 | None | code116 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.BASEMENT FLOOR | Sqm | 132.16 | 132.16 | 664.98 | False | None | None | False | None | False | 87883.7568 | 0 | 2439965 | 73427 | None | code117 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 133.48 | 133.48 | 1281.4 | False | None | None | False | None | False | 171041.272 | 0 | 2439966 | 73427 | None | code118 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOOR | Sqm | 134.8 | 134.8 | 62.7 | False | None | None | False | None | False | 8451.96 | 0 | 2439967 | 73427 | None | code119 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. BASEMENT FLOOR | Sqm | 152.32 | 152.32 | 225.4 | False | None | None | False | None | False | 34332.928 | 0 | 2439968 | 73427 | None | code120 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 153.84 | 153.84 | 359.8 | False | None | None | False | None | False | 55351.632 | 0 | 2439969 | 73427 | None | code121 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR | Sqm | 155.37 | 155.37 | 269.85 | False | None | None | False | None | False | 41926.5945 | 0 | 2439970 | 73427 | None | code122 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. BASEMENT FLOOR | Sqm | 232.96 | 232.96 | 22.54 | False | None | None | False | None | False | 5250.9184 | 0 | 2439971 | 73427 | None | code123 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 235.29 | 235.29 | 35.98 | False | None | None | False | None | False | 8465.7342 | 0 | 2439972 | 73427 | None | code124 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOOR | Sqm | 237.62 | 237.62 | 53.97 | False | None | None | False | None | False | 12824.3514 | 0 | 2439973 | 73427 | None | code125 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.BASEMENT FLOOR | Sqm | 145.6 | 145.6 | 2.4 | False | None | None | False | None | False | 349.44 | 0 | 2439974 | 73427 | None | code126 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 147.06 | 147.06 | 437.9 | False | None | None | False | None | False | 64397.574 | 0 | 2439975 | 73427 | None | code133 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.BASEMENT FLOOR | Kg | 560.0 | 560.0 | 60.8 | False | None | None | False | None | False | 34048.0 | 0 | 2439976 | 73427 | None | code134 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. GROUND FLOOR | Kg | 565.6 | 565.6 | 262.24 | False | None | None | False | None | False | 148322.944 | 0 | 2439977 | 73427 | None | code135 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:-PVC pipes 110mm dia., 6 kg/sqcm & class 3 | Rmtr | 441.28 | 441.28 | 100.0 | False | None | None | False | None | False | 44128.0 | 0 |
| 1707118939000 | 0 | None | None | Buildings | Construction of Market Building at Sy.No 290/1B1, Herga Village, Parkala ward in Udupi CMC Limit, Udupi Taluk and District.(PLUMBING AND SANITARY WORK) | 440583.74 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2439978 | 73428 | None | code01 | Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi -rigid, inorganic, non-combustible fibre glass wool insulation 50 mm thick, conforming to IS: 8183 and BS: 3958 Part 5. The insulation layer shall have facing (factory bonded on surface 1 of the fibre glass insulation layer), of black non-woven fibre glass tissue of nominal thickness 0.5 mm and nominal mass not less than 60 g/Sqm,made of randomly oriented glass fibres distributed in a binder by a wet-lay process including fixing | Sqm | 1749.44 | 1749.44 | 46.0 | False | None | None | False | None | False | 80474.24 | 0 | 2439979 | 73428 | None | code02 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required-White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests | No | 4755.52 | 4755.52 | 2.0 | False | None | None | False | None | False | 9511.04 | 0 | 2439980 | 73428 | None | code03 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid | No | 5605.6 | 5605.6 | 2.0 | False | None | None | False | None | False | 11211.2 | 0 | 2439981 | 73428 | None | code04 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and | Each | 7423.36 | 7423.36 | 2.0 | False | None | None | False | None | False | 14846.72 | 0 | 2439982 | 73428 | None | code05 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer | No | 4030.88 | 4030.88 | 4.0 | False | None | None | False | None | False | 16123.52 | 0 | 2439983 | 73428 | None | code06 | Providing and fixing 100 mm sand cast Iron grating for gully trap. | No | 229.6 | 229.6 | 10.0 | False | None | None | False | None | False | 2296.0 | 0 | 2439984 | 73428 | None | code07 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. | No | 646.24 | 646.24 | 15.0 | False | None | None | False | None | False | 9693.6 | 0 | 2439985 | 73428 | None | code08 | Providing and fixing C.P. brass long Noe bib cock of approved quality conforming to IS standards and weighing not less than 810 g. | No | 754.88 | 754.88 | 10.0 | False | None | None | False | None | False | 7548.8 | 0 | 2439986 | 73428 | None | code09 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) 25 mm nominal bore | No | 591.36 | 591.36 | 2.0 | False | None | None | False | None | False | 1182.72 | 0 | 2439987 | 73428 | None | code10 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) 32 mm nominal bore | No | 646.24 | 646.24 | 2.0 | False | None | None | False | None | False | 1292.48 | 0 | 2439988 | 73428 | None | code11 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) 40 mm nominal bore | No | 762.72 | 762.72 | 2.0 | False | None | None | False | None | False | 1525.44 | 0 | 2439989 | 73428 | None | code12 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) 50 mm nominal bore | No | 934.08 | 934.08 | 2.0 | False | None | None | False | None | False | 1868.16 | 0 | 2439990 | 73428 | None | code13 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) 65 mm nominal bore | No | 1556.8 | 1556.8 | 2.0 | False | None | None | False | None | False | 3113.6 | 0 | 2439991 | 73428 | None | code14 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) 80 mm nominal bore | No | 2302.72 | 2302.72 | 2.0 | False | None | None | False | None | False | 4605.44 | 0 | 2439992 | 73428 | None | code15 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. | No | 1087.52 | 1087.52 | 2.0 | False | None | None | False | None | False | 2175.04 | 0 | 2439993 | 73428 | None | code16 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. | No | 425.6 | 425.6 | 2.0 | False | None | None | False | None | False | 851.2 | 0 | 2439994 | 73428 | None | code17 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:-PVC pipes 160mm dia., 6 kg/sqcm & class 3-(basic rate 599- 7%) | Rmtr | 623.92 | 623.92 | 40.0 | False | None | None | False | None | False | 24956.8 | 0 | 2439995 | 73428 | None | code18 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:-PVC pipes 110mm dia., 6 kg/sqcm & class 3-(basic rate 394- 7%) | Rmtr | 415.6 | 415.6 | 30.0 | False | None | None | False | None | False | 12468.0 | 0 | 2439996 | 73428 | None | code19 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:-PVC pipes 90mm dia.,6kg/sqcm & class 3 (basic rate 281-7%) | Rmtr | 292.69 | 292.69 | 110.0 | False | None | None | False | None | False | 32195.9 | 0 | 2439997 | 73428 | None | code20 | Providing and fixing Chorinated Poly Venly Cloride (CPVC) pipes conforming to IS15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr. spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (concealed work including cutting chases and good the walls etc), For 50 mm dia | Rmtr | 859.04 | 859.04 | 60.0 | False | None | None | False | None | False | 51542.4 | 0 | 2439998 | 73428 | None | code21 | Providing and fixing Chorinated Poly Venly Cloride (CPVC) pipes conforming to IS15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr. spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (concealed work including cutting chases and good the walls etc), For 32 mm dia | Rmtr | 440.16 | 440.16 | 40.0 | False | None | None | False | None | False | 17606.4 | 0 | 2439999 | 73428 | None | code22 | Providing and fixing Chorinated Poly Venly Cloride (CPVC) pipes conforming to IS15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr. spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (concealed work including cutting chases and good the walls etc), For 25 mm dia | Rmtr | 353.92 | 353.92 | 30.0 | False | None | None | False | None | False | 10617.6 | 0 | 2440000 | 73428 | None | code23 | Providing and fixing Chorinated Poly Venly Cloride (CPVC) pipes conforming to IS15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr. spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (concealed work including cutting chases and good the walls etc), For 20 mm dia | No | 267.68 | 267.68 | 80.0 | False | None | None | False | None | False | 21414.4 | 0 | 2440001 | 73428 | None | code24 | Providing PVC-U INDIVIDUAL U.G.D House service connection (which shall be laid from inside the customer property ) which includes: a) Supply of PVC-U pipe (b) providing and fixing of 315 mm dia the PE Inspection chambres with lid consisting of inlet & outlet arrangements with base, riser of min. 0.42 m depth which includes earth work, fixing in CC-1:2:4 with appurtenances., complete. (c) civil works like Earthwork excavation for the pipeline trenches for laying of PVC-U pipes for the house connections in all types of soils , disintegrated rock,soft rock, hard rock, including cutting of any road using , crossing drains, compound, Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, c.c. wood work, steel work, including T & P and scaffolding wherever necessary sorting the dismantled material, disposal of unserviceable and stacking the serviceable material with all lifts and lead , restoring the damaged portions inside or outside the property premises, refilling the portions of trenches that are dug open including linking to existing sewer network with appurtenances. complete.Supply and fixing of SFRC machinhole cover (Medium Duty) made as per IS to suit existing damaged machinhole cover after removing the debries from inside and outside the existing machinhole etc. with all lead | No | 8761.76 | 8761.76 | 6.0 | False | None | None | False | None | False | 52570.56 | 0 | 2440002 | 73428 | None | code25 | KSRB 13-11 : Providing and placing on terrace, polyethylene water storage tanks as per IS 12701 : 1996 with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flow pipes, including cost of all materials, labour, transport charges, HOM and testing complete as per specifications. | Ltr | 8.96 | 8.96 | 2000.0 | False | None | None | False | None | False | 17920.0 | 0 | 2440003 | 73428 | None | code26 | Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 3 HP-3.00 HP - 155 LPM @ 42 m = 3 STG Outlet Dia - 2.00” | Each | 30972.48 | 30972.48 | 1.0 | False | None | None | False | None | False | 30972.48 | 0 |
| 1707118939000 | 0 | None | None | Buildings | Construction of Market Building at Sy.No 290/1B1, Herga Village, Parkala ward in Udupi CMC Limit, Udupi Taluk and District.(ELECTRIFICATION WORK) | 1939284.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2440004 | 73429 | None | code01 | INTERNAL WIRING & POWER POINTS PVC Conduit and its Accessories Concealed Conduit System Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. and running before Concreting the Slab. The Conduit should be tied to the reenforcement Rods by using binding wires and the unused ways of Junction boxes should be covered using PVC End enclosures .run with 18 SWG GI finish wire wherever it is necessory 19/20mm Dia 2mm Thick | Rmtr | 61.0 | 61.0 | 275.0 | False | None | None | False | None | False | 16775.0 | 0 | 2440005 | 73429 | None | code02 | INTERNAL WIRING & POWER POINTS PVC Conduit and its Accessories Concealed Conduit System Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. and running before Concreting the Slab. The Conduit should be tied to the reenforcement Rods by using binding wires and the unused ways of Junction boxes should be covered using PVC End enclosures .run with 18 SWG GI finish wire wherever it is necessory 25mm dia 2mm Thick | Rmtr | 70.0 | 70.0 | 385.0 | False | None | None | False | None | False | 26950.0 | 0 | 2440006 | 73429 | None | code03 | INTERNAL WIRING & POWER POINTS PVC Conduit and its Accessories Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. by groove cutting in the wall and fixing by bracing U or J hooks and plastering upto wall surface and .run with 18 SWG GI finish wire wherever it is necessory 19/20mm Dia 2mm Thick | Rmtr | 75.0 | 75.0 | 1276.0 | False | None | None | False | None | False | 95700.0 | 0 | 2440007 | 73429 | None | code04 | INTERNAL WIRING & POWER POINTS PVC Conduit and its Accessories Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. by groove cutting in the wall and fixing by bracing U or J hooks and plastering upto wall surface and .run with 18 SWG GI finish wire wherever it is necessory 25mm dia 2mm Thick | Rmtr | 80.0 | 80.0 | 3190.0 | False | None | None | False | None | False | 255200.0 | 0 | 2440008 | 73429 | None | code05 | INTERNAL WIRING & POWER POINTS PVC Conduit and its Accessories Supplying and fixing PVC/ Metal Conduit Deep Junction Boxes 25 mm Deep Junction Box | Each | 51.0 | 51.0 | 172.0 | False | None | None | False | None | False | 8772.0 | 0 | 2440009 | 73429 | None | code06 | INTERNAL WIRING & POWER POINTS Supply & Fixing of Metal fan box with round Hook | Each | 163.0 | 163.0 | 75.0 | False | None | None | False | None | False | 12225.0 | 0 | 2440010 | 73429 | None | code07 | INTERNAL WIRING & POWER POINTS Wires & Cables Point wiring using copper wire without Switch Supplying and wiring adopting loop system in existing PVC conduit/casing capping, using copper FRLS PVC insulated multi strand 2 x 1.5 sq.mm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block complete for each outlet. Make : KEI / Polycab/ FiNolex Short point upto 3 Mts. From Tapping point to outlet via switch box. | Point | 251.0 | 251.0 | 66.0 | False | None | None | False | None | False | 16566.0 | 0 | 2440011 | 73429 | None | code08 | INTERNAL WIRING & POWER POINTS Wires & Cables Point wiring using copper wire without Switch Supplying and wiring adopting loop system in existing PVC conduit/casing capping, using copper FRLS PVC insulated multi strand 2 x 1.5 sq.mm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block complete for each outlet. Make : KEI / Polycab/ FiNolex Medium point above 3 Mts upto 6 Mts. From tapping point to outlet via switch box. | Point | 361.0 | 361.0 | 106.0 | False | None | None | False | None | False | 38266.0 | 0 | 2440012 | 73429 | None | code09 | INTERNAL WIRING & POWER POINTS Wires & Cables Point wiring using copper wire without Switch Supplying and wiring adopting loop system in existing PVC conduit/casing capping, using copper FRLS PVC insulated multi strand 2 x 1.5 sq.mm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block complete for each outlet. Make : KEI / Polycab/ FiNolex Long point above 6 Mts. Upto 10 Mts. From tapping of point to outlet via switch box. | Point | 542.0 | 542.0 | 150.0 | False | None | None | False | None | False | 81300.0 | 0 | 2440013 | 73429 | None | code10 | INTERNAL WIRING & POWER POINTS Wires & Cables Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring 1.5 Sqmm | Rmtr | 26.0 | 26.0 | 1276.0 | False | None | None | False | None | False | 33176.0 | 0 | 2440014 | 73429 | None | code11 | INTERNAL WIRING & POWER POINTS Wires & Cables Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring 2.5Sqmm | Rmtr | 40.0 | 40.0 | 4257.0 | False | None | None | False | None | False | 170280.0 | 0 | 2440015 | 73429 | None | code12 | INTERNAL WIRING & POWER POINTS Wires & Cables Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring 4Sqmm | Rmtr | 59.0 | 59.0 | 1870.0 | False | None | None | False | None | False | 110330.0 | 0 | 2440016 | 73429 | None | code13 | INTERNAL WIRING & POWER POINTS Wires & Cables Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring 6Sqmm | Rmtr | 70.0 | 70.0 | 200.0 | False | None | None | False | None | False | 14000.0 | 0 | 2440017 | 73429 | None | code14 | Switches Sockets and Accessories Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall Make : Anchor / Schneider / Legrand 6 way | Each | 212.0 | 212.0 | 121.0 | False | None | None | False | None | False | 25652.0 | 0 | 2440018 | 73429 | None | code15 | Switches Sockets and Accessories Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall Make : Anchor / Schneider / Legrand 8 way | Each | 250.0 | 250.0 | 61.0 | False | None | None | False | None | False | 15250.0 | 0 | 2440019 | 73429 | None | code16 | Switches Sockets and Accessories Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall Make : Anchor / Schneider / Legrand 12 way | Each | 325.0 | 325.0 | 2.0 | False | None | None | False | None | False | 650.0 | 0 | 2440020 | 73429 | None | code17 | Switches Sockets and Accessories Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required No. of machine screws , bolts nuts etc. complte on existing metal / PVC box Make : Anchor / Schneider / Legrand 6 way | Each | 244.0 | 244.0 | 121.0 | False | None | None | False | None | False | 29524.0 | 0 | 2440021 | 73429 | None | code18 | Switches Sockets and Accessories Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required No. of machine screws , bolts nuts etc. complte on existing metal / PVC box Make : Anchor / Schneider / Legrand 8 way | Each | 302.0 | 302.0 | 61.0 | False | None | None | False | None | False | 18422.0 | 0 | 2440022 | 73429 | None | code19 | Switches Sockets and Accessories Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required No. of machine screws , bolts nuts etc. complte on existing metal / PVC box Make : Anchor / Schneider / Legrand 10-12 way | Each | 363.0 | 363.0 | 2.0 | False | None | None | False | None | False | 726.0 | 0 | 2440023 | 73429 | None | code20 | Switches Sockets and Accessories Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate Make : Anchor / Schneider / Legrand 6 Amp one way | Each | 88.0 | 88.0 | 290.0 | False | None | None | False | None | False | 25520.0 | 0 | 2440024 | 73429 | None | code21 | Switches Sockets and Accessories Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate Make : Anchor / Schneider / Legrand 6 Amps socket | Each | 162.0 | 162.0 | 53.0 | False | None | None | False | None | False | 8586.0 | 0 | 2440025 | 73429 | None | code22 | Switches Sockets and Accessories Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate Make : Anchor / Schneider / Legrand Stepped Fan Regulator | Each | 313.0 | 313.0 | 75.0 | False | None | None | False | None | False | 23475.0 | 0 | 2440026 | 73429 | None | code23 | Switches Sockets and Accessories Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate Make : Anchor / Schneider / Legrand 16 Amps 1 way switch | Each | 249.0 | 249.0 | 81.0 | False | None | None | False | None | False | 20169.0 | 0 | 2440027 | 73429 | None | code24 | Switches Sockets and Accessories Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate Make : Anchor / Schneider / Legrand 6/16 Amps universal socket | Each | 249.0 | 249.0 | 81.0 | False | None | None | False | None | False | 20169.0 | 0 | 2440028 | 73429 | None | code25 | LUMINERIES & LIGHT FIXTURES & ACCESSORIES Make : Panasonic/Phillips / Crompton Led Light Fixture 2 feet - 9/10 W | Each | 496.0 | 496.0 | 4.0 | False | None | None | False | None | False | 1984.0 | 0 | 2440029 | 73429 | None | code26 | LUMINERIES & LIGHT FIXTURES & ACCESSORIES Make : Panasonic/Phillips / Crompton Led Light Fixture 4 feet - 20/22 W | Each | 740.0 | 740.0 | 236.0 | False | None | None | False | None | False | 174640.0 | 0 | 2440030 | 73429 | None | code27 | PANEL & DISTRIBUTION BOARDS PANELS Make : Legrand / Schneider / Anchor / L&T Fabrication and supply of sheet steel enclosure out of 14 SWG CRCA Sheet duly powder coated the contro panel ( Size of 2000 x1500x 450 ) is of compartment alized, All the components are duly wired and connected to Aluminum bus bar. | Each | 0.43 | 0.43 | 50000.0 | False | None | None | False | None | False | 21500.0 | 0 | 2440031 | 73429 | None | code28 | PANEL & DISTRIBUTION BOARDS PANELS Make : Legrand / Schneider / Anchor / L&T Supplying and fixing of 250 A 4 x 30 x 10 mm Alumunium Strips | Rmtr | 3078.0 | 3078.0 | 12.0 | False | None | None | False | None | False | 36936.0 | 0 | 2440032 | 73429 | None | code29 | PANEL & DISTRIBUTION BOARDS PANELS Make : Legrand / Schneider / Anchor / L&T 16 sqmm wire | Rmtr | 318.0 | 318.0 | 40.0 | False | None | None | False | None | False | 12720.0 | 0 | 2440033 | 73429 | None | code30 | PANEL & DISTRIBUTION BOARDS PANELS Make : Legrand / Schneider / Anchor / L&T Supplying and fixing of LED Panel Board indicating Lamp with required colour Suitable for 220 V AC 50 HZ | Each | 464.0 | 464.0 | 6.0 | False | None | None | False | None | False | 2784.0 | 0 | 2440034 | 73429 | None | code31 | PANEL & DISTRIBUTION BOARDS PANELS Make : Legrand / Schneider / Anchor / L&T Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5to 20A single phase Class-1 Accuracy with Temper ProofEnergy Meter. | Each | 1150.0 | 1150.0 | 15.0 | False | None | None | False | None | False | 17250.0 | 0 | 2440035 | 73429 | None | code32 | PANEL & DISTRIBUTION BOARDS PANELS Make : Legrand / Schneider / Anchor / L&T Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 A three phase 4 wire whole current class-1 Accuracy Energy Meter. | Each | 5125.0 | 5125.0 | 4.0 | False | None | None | False | None | False | 20500.0 | 0 | 2440036 | 73429 | None | code33 | PANEL & DISTRIBUTION BOARDS PANELS Make : Legrand / Schneider / Anchor / L&T Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SMEnclosure Sheet Metal Execution) 200A | Each | 14417.0 | 14417.0 | 1.0 | False | None | None | False | None | False | 14417.0 | 0 | 2440037 | 73429 | None | code34 | PANEL & DISTRIBUTION BOARDS PANELS Make : Legrand / Schneider / Anchor / L&T 125A ATS | Each | 74520.0 | 74520.0 | 1.0 | False | None | None | False | None | False | 74520.0 | 0 | 2440038 | 73429 | None | code35 | PANEL & DISTRIBUTION BOARDS PANELS Make : Legrand / Schneider / Anchor / L&T Supplying and fixing of 200 A MCCB | Each | 21289.0 | 21289.0 | 2.0 | False | None | None | False | None | False | 42578.0 | 0 | 2440039 | 73429 | None | code36 | PANEL & DISTRIBUTION BOARDS PANELS Make : Legrand / Schneider / Anchor / L&T 63A 4P MCB | Each | 2399.0 | 2399.0 | 4.0 | False | None | None | False | None | False | 9596.0 | 0 | 2440040 | 73429 | None | code37 | PANEL & DISTRIBUTION BOARDS PANELS Make : Legrand / Schneider / Anchor / L&T 5 - 32 A TPN | Nos | 1777.0 | 1777.0 | 8.0 | False | None | None | False | None | False | 14216.0 | 0 | 2440041 | 73429 | None | code38 | PANEL & DISTRIBUTION BOARDS PANELS Make : Legrand / Schneider / Anchor / L&T Supplying and fixing of Earth leakage relay | Each | 8316.0 | 8316.0 | 1.0 | False | None | None | False | None | False | 8316.0 | 0 | 2440042 | 73429 | None | code39 | PANEL & DISTRIBUTION BOARDS PANELS Make : Legrand / Schneider / Anchor / L&T Supplying and fixing of 50 x 50 x 6 mm Angle | Rmtr | 356.0 | 356.0 | 10.0 | False | None | None | False | None | False | 3560.0 | 0 | 2440043 | 73429 | None | code40 | PANEL & DISTRIBUTION BOARDS PANELS Make : Legrand / Schneider / Anchor / L&T 0 | Rmtr | 1.0 | 1.0 | 1.0 | False | None | None | False | None | False | 1.0 | 0 | 2440044 | 73429 | None | code48 | PANEL & DISTRIBUTION BOARDS 40 KVAR APFC Panel Make : Legrand / Schneider / Anchor / L&T Supplying and fixing of Heavy Duty low Voltage Capacitors | Kvar | 432.0 | 432.0 | 10.0 | False | None | None | False | None | False | 4320.0 | 0 | 2440045 | 73429 | None | code49 | Supplying and fixing regular MCB distribution Boards on Wall / wood board /flush mounting using required clamps bolts nuts etc with provision for fixing suitable type capacity MCB single phase / 3 phase / single door with powder coated paiting 8Way SP &N | No | 1695.0 | 1695.0 | 12.0 | False | None | None | False | None | False | 20340.0 | 0 | 2440046 | 73429 | None | code50 | Supplying and fixing regular MCB distribution Boards on Wall / wood board /flush mounting using required clamps bolts nuts etc with provision for fixing suitable type capacity MCB single phase / 3 phase / single door with powder coated paiting 12Way SP &N | No | 2067.0 | 2067.0 | 2.0 | False | None | None | False | None | False | 4134.0 | 0 | 2440047 | 73429 | None | code51 | Supplying and fixing regular MCB distribution Boards on Wall / wood board /flush mounting using required clamps bolts nuts etc with provision for fixing suitable type capacity MCB single phase / 3 phase / single door with powder coated paiting 6Way TP &N | No | 3735.0 | 3735.0 | 3.0 | False | None | None | False | None | False | 11205.0 | 0 | 2440048 | 73429 | None | code52 | Supplying fixing & wiring earth leakage miniature circuit breaker (ELMCB) 240 / 450 V up to 300mA sensitivity on Existing / panel Board 16 - 25 Amps 2 pole | No | 2536.0 | 2536.0 | 20.0 | False | None | None | False | None | False | 50720.0 | 0 | 2440049 | 73429 | None | code53 | Supplying fixing & wiring earth leakage miniature circuit breaker (ELMCB) 240 / 450 V up to 300mA sensitivity on Existing / panel Board 32 - 40 Amps 4 pole | No | 2826.0 | 2826.0 | 2.0 | False | None | None | False | None | False | 5652.0 | 0 | 2440050 | 73429 | None | code54 | Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898 5 - 32 Amp SP | No | 523.0 | 523.0 | 130.0 | False | None | None | False | None | False | 67990.0 | 0 | 2440051 | 73429 | None | code55 | Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898 5 - 32 Amp DP | No | 1103.0 | 1103.0 | 2.0 | False | None | None | False | None | False | 2206.0 | 0 | 2440052 | 73429 | None | code56 | Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898 5 - 32 A TPN | No | 1777.0 | 1777.0 | 3.0 | False | None | None | False | None | False | 5331.0 | 0 | 2440053 | 73429 | None | code57 | Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898 40 - 63 Amp TPN | No | 2399.0 | 2399.0 | 1.0 | False | None | None | False | None | False | 2399.0 | 0 | 2440054 | 73429 | None | code58 | SERVICE MAINS & WORK UNDER UG CABLE , EARTHING Supplying Fixing and Wiring earth electrode for grounding of lifts,Xmer, DG Sets etc using 40mm dia 2.9mm thick, 2.5mtr long GI pipe with GI funnel with mesh & suitable size reducer fixed on the top of Electrode. The funnel should be enclosed in a cc chamber of 400x400x400 with a cast iron cover. The Earth electrode shall have staggered holes of 12mm dia & electrode shoulde be covered 150mm around with alternate layers of salt & charcoal from the bottom of the CC Chamber. The connection from the electrode is to be established throgh GI strip using GI bolts & nuts. | No | 4150.0 | 4150.0 | 8.0 | False | None | None | False | None | False | 33200.0 | 0 | 2440055 | 73429 | None | code59 | SERVICE MAINS & WORK UNDER UG CABLE , EARTHING 25 x 3 mm G.I strip. | Rmtr | 75.0 | 75.0 | 100.0 | False | None | None | False | None | False | 7500.0 | 0 | 2440056 | 73429 | None | code60 | SERVICE MAINS & WORK UNDER UG CABLE , EARTHING 600x600x3 GI Plate | Each | 760.0 | 760.0 | 2.0 | False | None | None | False | None | False | 1520.0 | 0 | 2440057 | 73429 | None | code61 | SERVICE MAINS & WORK UNDER UG CABLE , EARTHING 25 x 3 mm | Rmtr | 505.0 | 505.0 | 20.0 | False | None | None | False | None | False | 10100.0 | 0 | 2440058 | 73429 | None | code62 | SERVICE MAINS & WORK UNDER UG CABLE , EARTHING 600x600x3 Cu. Plate | Each | 6900.0 | 6900.0 | 2.0 | False | None | None | False | None | False | 13800.0 | 0 | 2440059 | 73429 | None | code63 | SERVICE MAINS & WORK UNDER UG CABLE , EARTHING 12 SWG GI wire | Rmtr | 14.0 | 14.0 | 200.0 | False | None | None | False | None | False | 2800.0 | 0 | 2440060 | 73429 | None | code64 | SERVICE MAINS & WORK UNDER UG CABLE , EARTHING 8 SWG | Rmtr | 105.0 | 105.0 | 50.0 | False | None | None | False | None | False | 5250.0 | 0 | 2440061 | 73429 | None | code65 | Supply & Fixing of Heavy Duty Cable Glands Suitable For UG Cable of 1.1KV Class (metal Only) 25mm Dia | No | 84.0 | 84.0 | 2.0 | False | None | None | False | None | False | 168.0 | 0 | 2440062 | 73429 | None | code66 | Supply & Fixing of Heavy Duty Cable Glands Suitable For UG Cable of 1.1KV Class (metal Only) 63mm Dia | No | 400.0 | 400.0 | 1.0 | False | None | None | False | None | False | 400.0 | 0 | 2440063 | 73429 | None | code67 | Supply & Fixing 2mm thick perforated cable tray with powder coated paint on exising MS Angle support using necessary GI bolts , nuts & washer or welding as required: 150 mmX 50 MM wide tray ( Perforated type ) | Rmtr | 425.0 | 425.0 | 20.0 | False | None | None | False | None | False | 8500.0 | 0 | 2440064 | 73429 | None | code68 | Supply & Fixing 2mm thick perforated cable tray with powder coated paint on exising MS Angle support using necessary GI bolts , nuts & washer or welding as required: 300 mm x 50 mm wide cabel tray ( Perforated type ) | Rmtr | 530.0 | 530.0 | 20.0 | False | None | None | False | None | False | 10600.0 | 0 | 2440065 | 73429 | None | code69 | FANS & AIR CONDITIONERS Make Fans : Crompton / Usha / Anchor Supplying exhaust fan 0f 1440 RPM of300 mm (12") size with bracket blades complte for light duty suitable to operate on 230V 50 Hz AC Supply | Each | 1542.0 | 1542.0 | 4.0 | False | None | None | False | None | False | 6168.0 | 0 | 2440066 | 73429 | None | code70 | FANS & AIR CONDITIONERS Make Fans : Crompton / Usha / Anchor Supplying capacitor type ceiling Fan complete with down rod blades shackle ,caNopies etc. for operation on 230 Vots 50 cycles ,single phase AC supply confirming to ISS -374-1979 with double ball bearing system 48 " Sweep EcoNomy model | Each | 2085.0 | 2085.0 | 68.0 | False | None | None | False | None | False | 141780.0 | 0 |
| 1707118939000 | 0 | None | None | Buildings | Construction of Market Building at Sy.No 290/1B1, Herga Village, Parkala ward in Udupi CMC Limit, Udupi Taluk and District.(COMPOUND WALL) | 459628.83 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2440067 | 73430 | None | code01 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work-In all kinds of soils Depth upto 3 m. Page No. 8,Sl. No.1.14..1,VOL-1 | Cum | 81.76 | 81.76 | 26.25 | False | None | None | False | None | False | 2146.2 | 0 | 2440068 | 73430 | None | code02 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates. sl.no-2.1.2, pg.no-15. volume-1 | Cum | 5830.72 | 5830.72 | 3.68 | False | None | None | False | None | False | 21457.0496 | 0 | 2440069 | 73430 | None | code03 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) Sl.no-5.4, page no-9,volume-2. | Cum | 5994.24 | 5994.24 | 16.54 | False | None | None | False | None | False | 99144.7296 | 0 | 2440070 | 73430 | None | code04 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. S.No. 6.33, Page No.17, Volume-2. | Sqm | 1188.32 | 1188.32 | 122.85 | False | None | None | False | None | False | 145985.112 | 0 | 2440071 | 73430 | None | code05 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates sl.no-2.5.2, page no-17, volume-I. | Cum | 10392.48 | 10392.48 | 3.67 | False | None | None | False | None | False | 38140.4016 | 0 | 2440072 | 73430 | None | code06 | Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) Sl. No. 11.32 , Page No.84, Volume-2. | Kg | 107.52 | 107.52 | 183.4 | False | None | None | False | None | False | 19719.168 | 0 | 2440073 | 73430 | None | code07 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl. No. 8.9, Page No.42, Volume-2. | Sqm | 360.64 | 360.64 | 259.35 | False | None | None | False | None | False | 93531.984 | 0 | 2440074 | 73430 | None | code08 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.30, Page No.46, Volume-2. | Sqm | 152.32 | 152.32 | 259.35 | False | None | None | False | None | False | 39504.192 | 0 |
| 1707118939000 | 0 | None | None | Buildings | Construction of Market Building at Sy.N 290/1B1, Herga Village, Parkala ward in Udupi CMC Limit, Udupi Taluk and District.(UNDER GROUND WATER TANK (5KLD) | 188877.9 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2440075 | 73431 | None | code01 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work-In all kinds of soils Depth upto 3 m | Cum | 81.76 | 81.76 | 35.59 | False | None | None | False | None | False | 2909.8384 | 0 | 2440076 | 73431 | None | code02 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse | Cum | 5830.72 | 5830.72 | 1.81 | False | None | None | False | None | False | 10553.6032 | 0 | 2440077 | 73431 | None | code03 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 228.48 | 228.48 | 22.67 | False | None | None | False | None | False | 5179.6416 | 0 | 2440078 | 73431 | None | code04 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 20% ON CONCRETE ITEM) | Cum | 8313.98 | 8313.98 | 6.43 | False | None | None | False | None | False | 53458.8914 | 0 | 2440079 | 73431 | None | code05 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineerin-Charge.. | Sqm | 417.76 | 417.76 | 66.62 | False | None | None | False | None | False | 27831.1712 | 0 | 2440080 | 73431 | None | code06 | KSRB 12-6.2: Providing 20mm round M.S. footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6 | No | 286.72 | 286.72 | 10.0 | False | None | None | False | None | False | 2867.2 | 0 | 2440081 | 73431 | None | code07 | Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | Kg | 103.04 | 103.04 | 835.38 | False | None | None | False | None | False | 86077.5552 | 0 |
| 1707118939000 | 0 | None | None | Buildings | Construction of Market Building at Sy.No 290/1B1, Herga Village, Parkala ward in Udupi CMC Limit, Udupi Taluk and District.9(SEPTIC TANK) | 365788.61 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2440082 | 73432 | None | code01 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work-In all kinds of soils Depth upto 3 m | Cum | 81.76 | 81.76 | 46.87 | False | None | None | False | None | False | 3832.0912 | 0 | 2440083 | 73432 | None | code02 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse | Cum | 5830.72 | 5830.72 | 2.62 | False | None | None | False | None | False | 15276.4864 | 0 | 2440084 | 73432 | None | code03 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 228.48 | 228.48 | 32.18 | False | None | None | False | None | False | 7352.4864 | 0 | 2440085 | 73432 | None | code04 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 20% ON CONCRETE ITEM) | Cum | 8313.98 | 8313.98 | 12.79 | False | None | None | False | None | False | 106335.8042 | 0 | 2440086 | 73432 | None | code05 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineerin-Charge. | Sqm | 417.76 | 417.76 | 136.32 | False | None | None | False | None | False | 56949.0432 | 0 | 2440087 | 73432 | None | code06 | KSRB 12-6.2: Providing 20mm round M.S. footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6 | No | 286.72 | 286.72 | 10.0 | False | None | None | False | None | False | 2867.2 | 0 | 2440088 | 73432 | None | code07 | Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | Kg | 103.04 | 103.04 | 1662.44 | False | None | None | False | None | False | 171297.8176 | 0 | 2440089 | 73432 | None | code08 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work-In all kinds of soils Depth upto 3 m | Cum | 81.76 | 81.76 | 2.0 | False | None | None | False | None | False | 163.52 | 0 | 2440090 | 73432 | None | code09 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge | Cum | 1075.2 | 1075.2 | 1.0 | False | None | None | False | None | False | 1075.2 | 0 | 2440091 | 73432 | None | code10 | Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | Cum | 416.64 | 416.64 | 1.0 | False | None | None | False | None | False | 416.64 | 0 | 2440092 | 73432 | None | code11 | Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. | Cum | 444.64 | 444.64 | 0.5 | False | None | None | False | None | False | 222.32 | 0 |
| 1707118939000 | 0 | None | None | Buildings | Construction of Market Building at Sy.No 290/1B1, Herga Village, Parkala ward in Udupi CMC Limit, Udupi Taluk and District.(RAIN WATER RECHARGE PIT) | 10386.88 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2440093 | 73433 | None | code01 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work-In all kinds of soils Depth upto 3 m | Cum | 81.76 | 81.76 | 6.0 | False | None | None | False | None | False | 490.56 | 0 | 2440094 | 73433 | None | code02 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge | Cum | 1075.2 | 1075.2 | 6.0 | False | None | None | False | None | False | 6451.2 | 0 | 2440095 | 73433 | None | code03 | Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | Cum | 416.64 | 416.64 | 4.0 | False | None | None | False | None | False | 1666.56 | 0 | 2440096 | 73433 | None | code04 | Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. | Cum | 444.64 | 444.64 | 4.0 | False | None | None | False | None | False | 1778.56 | 0 |
| 1707118939000 | 0 | None | None | Buildings | Construction of Market Building at Sy.No 290/1B1, Herga Village, Parkala ward in Udupi CMC Limit, Udupi Taluk and District.(INTERLOCK PAVERS FOR PARKING) | 399236.99 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2440097 | 73434 | None | code01 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.- Page No. 24,Sl. No.4.27 VOL-3 | Cum | 2681.28 | 2681.28 | 25.4 | False | None | None | False | None | False | 68104.512 | 0 | 2440098 | 73434 | None | code02 | Painting lines, dashes, arrows etc on roads in two coats on new work with ready mixed road marking paint conforming to IS:164:2015 on bituminous surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control-Page No. 56,Sl. No.8.13, VOL-3 | Sqm | 150.08 | 150.08 | 36.0 | False | None | None | False | None | False | 5402.88 | 0 | 2440099 | 73434 | None | code03 | Providing and laying heavy duty cobble stones 75mm thick interlock pavers, using cement and course sand for manufacture of blocks of approved size, shape and colour with a minimum compressive strength of 281 kg per m2 over 50mm thick sand bed ( average thickness ) and compacting with plate vibrator having 3 tons compaction force thereby forcing part of sand underneath to come up in between joints, final compaction of paver surface joints into its final level, including cost of materials, labour and Usage charges of machinery complete as per specifications. Page No.64 ,Sl. No. 9.32, VOL-2 | Sqm | 1282.4 | 1282.4 | 254.0 | False | None | None | False | None | False | 325729.6 | 0 |
| 1707118939000 | 0 | None | None | Buildings | Construction of Market Building at Sy.No 290/1B1, Herga Village, Parkala ward in Udupi CMC Limit, Udupi Taluk and District.(CULVERTS) | 406578.96 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2440100 | 73435 | None | code01 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work-In all kinds of soils Depth upto 3 m | Cum | 81.76 | 81.76 | 32.4 | False | None | None | False | None | False | 2649.024 | 0 | 2440101 | 73435 | None | code02 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse | Cum | 5830.72 | 5830.72 | 2.19 | False | None | None | False | None | False | 12769.2768 | 0 | 2440102 | 73435 | None | code03 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 228.48 | 228.48 | 29.4 | False | None | None | False | None | False | 6717.312 | 0 | 2440103 | 73435 | None | code04 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 20% ON CONCRETE ITEM) | Cum | 8313.98 | 8313.98 | 14.7 | False | None | None | False | None | False | 122215.506 | 0 | 2440104 | 73435 | None | code05 | Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | Kg | 103.04 | 103.04 | 1911.0 | False | None | None | False | None | False | 196909.44 | 0 | 2440105 | 73435 | None | code06 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 120.96 | 120.96 | 540.0 | False | None | None | False | None | False | 65318.4 | 0 |
|
|
---|