| 2807792 | 90436 | None | 1.12 V-1 | Earth work in surface excavation by mechanical means for lowering &leveling the ground for allworks other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technicalspecifications, including setting out,shoring, strutting, barricading, cautionlights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing of for levelling the excavated earth or sorting & stacking the selected earth forreuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.Including with all lead and lifts as per the direction engineer incharge | Cum | 99.75 | 99.75 | 94.23 | False | None | None | False | None | False | 9399.4425 | 0 |
| 2807793 | 90436 | None | 1.15.1 V-1 | Earth work excavation for Foundation by mechanical means for allworks& depth upto 3 m, as per drawing and technicalspecifications,including setting out,shoring, strutting, barricading, caution lights,including dressing of excavated surfaces, disposing off or levelling theexcavated earth or sorting & stacking the selected earth for reuse in aradius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery &other appurtenaces required to complete the work Inordinary/softrock without blasting upto1.5m depth Including with all lead and lifts as per the direction engineer incharge | Cum | 381.15 | 381.15 | 187.89 | False | None | None | False | None | False | 71614.2735 | 0 |
| 2807794 | 90436 | None | 1.23 V-1 | Providing Filling in foundation with granite/ trap broken metal 100mm and down size with approved sand including hand packing, ramming, watering including cost of all materials and labour with lead up to 50m and lift of 1.5m complete as per specifications. Including with all lead and lifts as per the direction engineer incharge | Cum | 2816.1 | 2816.1 | 55.94 | False | None | None | False | None | False | 157532.634 | 0 |
| 2807795 | 90436 | None | 2.1.2 V-1 | Providing and laying in position plain cement concrete for levellingcourse for all works in foundation. Thegranite/trap/basaltcrushedgraded coarse aggregatesand fine aggregatesas per relevant IS Codes machine mixed, laid in layers not exceeding150mm thickness, well compacted using plate vibrators, including all lead & lifts,cost of all materials of quality, labour, Usage charges of machineries, curing,and all the other appurtenances required to complete the work as pertechnical specifications. Mix1:4:8 (M5) Using 40mm nominal size graded crushed coarse aggregates Including with all lead and lifts as per the direction engineer incharge | Cum | 5947.2 | 5947.2 | 55.39 | False | None | None | False | None | False | 329415.408 | 0 |
| 2807796 | 90436 | None | 2.1.4 V-1 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately).Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates Including with all lead and lifts as per the direction engineer incharge | Cum | 6527.85 | 6527.85 | 4.17 | False | None | None | False | None | False | 27221.1345 | 0 |
| 2807797 | 90436 | None | 2.2.1 V-1 | Providing and laying in position Reinforced cement concretefor all Foundation works. Thegranite/trap/basaltcrushed graded coarseaggregatesand fine aggregatesas per relevant IS Codes machinemixed with super plasticizerslaid in finished layers, well compactedusing needle vibrators,including all lead & lifts,cost of all materials,quality confirming to the requirements ofrelevant IS codes , labour,Usage charges of machinery,curing and all the other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20mm nominal size graded crushed coarse aggregates Additionalities for form work, Centering & Scaffolding Footing Including with all lead and lifts as per the direction engineer incharge | Cum | 7104.31 | 7104.31 | 20.66 | False | None | None | False | None | False | 146775.0446 | 0 |
| 2807798 | 90436 | None | 2.2.1 V-1 | Providing and laying in position Reinforced cement concretefor all Foundation works. Thegranite/trap/basaltcrushed graded coarseaggregatesand fine aggregatesas per relevant IS Codes machinemixed with super plasticizerslaid in finished layers, well compactedusing needle vibrators,including all lead & lifts,cost of all materials,quality confirming to the requirements ofrelevant IS codes , labour,Usage charges of machinery,curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20mm nominal size graded crushed coarse aggregates Additionalities for form work, Centering & Scaffolding Columns Including with all lead and lifts as per the direction engineer incharge | Cum | 11002.25 | 11002.25 | 2.8 | False | None | None | False | None | False | 30806.3 | 0 |
| 2807799 | 90436 | None | 5.4 V-2 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) Including with all lead and lifts as per the direction engineer incharge | Cum | 6708.45 | 6708.45 | 31.28 | False | None | None | False | None | False | 209840.316 | 0 |
| 2807800 | 90436 | None | 2.3.1 V-1 | Providing and laying in Reinforced cement concretefor all Basement & surface level works, return walls, retaining walls, sunken floors etc. Thegranite /trap/ basalt crushed graded coarse aggregates and fine aggregatesas per relevant IS Codes machine mixed with superplasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts,costof all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20mm nominal size graded crushed coarse aggregates. Additionalities for form work, Centering & Scaffolding for Plinth Beam Including with all lead and lifts as per the direction engineer incharge | Cum | 9800.65 | 9800.65 | 15.67 | False | None | None | False | None | False | 153576.1855 | 0 |
| 2807801 | 90436 | None | 2.5.1 V-1 | Providing and laying in position Reinforced cement concretefor all Super structures of building,Roadworks,Waterworks,Irrigationworks& super structure works of bridgesupto 3.50 m height. Thegranite/trap/basaltcrushed graded coarse aggregatesand fine aggregatesas per relevant IS Codes machine mixed with super plasticisers laid inlayers, well compacted using needlevibrators. The cost includes alllead & lifts, cost of all materials, quality confirming to the requirementsof relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20mm nominal size graded crushed coarse aggregates Additionalities for form work, Centering & Scaffolding for Columns Including with all lead and lifts as per the direction engineer incharge | Cum | 11602.5 | 11602.5 | 11.15 | False | None | None | False | None | False | 129367.875 | 0 |
| 2807802 | 90436 | None | 2.5.1 V-1 | Providing and laying in position Reinforced cement concretefor all Super structures of building,Roadworks,Waterworks,Irrigationworks& super structure works of bridgesupto 3.50 m height. Thegranite/trap/basaltcrushed graded coarse aggregatesand fine aggregatesas per relevant IS Codes machine mixed with super plasticisers laid inlayers, well compacted using needlevibrators. The cost includes alllead & lifts, cost of all materials, quality confirming to the requirementsof relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20mm nominal size graded crushed coarse aggregates Additionalities for form work, Centering & Scaffolding for Chajja Including with all lead and lifts as per the direction engineer incharge | Cum | 9945.0 | 9945.0 | 0.68 | False | None | None | False | None | False | 6762.6 | 0 |
| 2807803 | 90436 | None | 2.5.1 V-1 | Providing and laying in position Reinforced cement concretefor all Super structures of building,Roadworks,Waterworks,Irrigationworks& super structure works of bridgesupto 3.50 m height. Thegranite/trap/basaltcrushed graded coarse aggregatesand fine aggregatesas per relevant IS Codes machine mixed with super plasticisers laid inlayers, well compacted using needlevibrators. The cost includes alllead & lifts, cost of all materials, quality confirming to the requirementsof relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20mm nominal size graded crushed coarse aggregates Additionalities for form work, Centering & Scaffolding for Lintels, Beams Including with all lead and lifts as per the direction engineer incharge | Cum | 10939.5 | 10939.5 | 20.08 | False | None | None | False | None | False | 219665.16 | 0 |
| 2807804 | 90436 | None | 2.5.1 V-1 | Providing and laying in position Reinforced cement concretefor all Super structures of building,Roadworks,Waterworks,Irrigationworks& super structure works of bridgesupto 3.50 m height. Thegranite/trap/basaltcrushed graded coarse aggregatesand fine aggregatesas per relevant IS Codes machine mixed with super plasticisers laid inlayers, well compacted using needlevibrators. The cost includes alllead & lifts, cost of all materials, quality confirming to the requirementsof relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20mm nominal size graded crushed coarse aggregates Additionalities for form work, Centering & Scaffolding roof Including with all lead and lifts as per the direction engineer incharge | Cum | 10276.5 | 10276.5 | 47.06 | False | None | None | False | None | False | 483612.09 | 0 |
| 2807805 | 90436 | None | 1.90 V-1 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming andwatering,leadupto 50m andliftupto1.5m Including with all lead and lifts as per the direction engineer incharge | Cum | 279.3 | 279.3 | 236.79 | False | None | None | False | None | False | 66135.447 | 0 |
| 2807806 | 90436 | None | 6.2 V-2 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Including with all lead and lifts as per the direction engineer incharge | Cum | 8376.9 | 8376.9 | 89.2 | False | None | None | False | None | False | 747219.48 | 0 |
| 2807807 | 90436 | None | 2.11 V-1 | Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. Including with all lead and lifts as per the direction engineer incharge | Tonne | 93929.9 | 93929.9 | 11.7566 | False | None | None | False | None | False | 1104296.26234 | 0 |
| 2807808 | 90436 | None | 11.5.1 V-2 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Including with all lead and lifts as per the direction engineer incharge | Sqm | 4701.9 | 4701.9 | 12.6 | False | None | None | False | None | False | 59243.94 | 0 |
| 2807809 | 90436 | None | 11.34A V-2 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding Including with all lead and lifts as per the direction engineer incharge | Kg | 176.4 | 176.4 | 604.8 | False | None | None | False | None | False | 106686.72 | 0 |
| 2807810 | 90436 | None | 11.35.2.1 V-2 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) including cost ofmaterials,labour,usage charges of machinery complete as per specifications.Including with all lead and lifts as per the direction engineer incharge | Kg | 560.7 | 560.7 | 194.4 | False | None | None | False | None | False | 109000.08 | 0 |
| 2807811 | 90436 | None | 11.11.1 V-2 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Including with all lead and lifts as per the direction engineer incharge | Kg | 155.4 | 155.4 | 151.2 | False | None | None | False | None | False | 23496.48 | 0 |
| 2807812 | 90436 | None | 8.2.1 V-2 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Including with all lead and lifts as per the direction engineer incharge | Sqm | 309.75 | 309.75 | 560.18 | False | None | None | False | None | False | 173515.755 | 0 |
| 2807813 | 90436 | None | 8.3.1 V-2 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Including with all lead and lifts as per the direction engineer incharge | Sqm | 371.7 | 371.7 | 624.52 | False | None | None | False | None | False | 232134.084 | 0 |
| 2807814 | 90436 | None | 9.23 V-2 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rub bing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :** Flamed finish granite stone slab Black, Cat Eye, River Pink or equivalent.Including with all lead and lifts as per the direction engineer incharge | Sqm | 2589.3 | 2589.3 | 271.31 | False | None | None | False | None | False | 702502.983 | 0 |
| 2807815 | 90436 | None | 8.84 V-2 | Providing wall black boards in 12mm thick with CM 1:3 and applied with primer & two coats of acrylic emulsion black paint including finishing etc.,complete.Including with all lead and lifts as per the direction engineer incharge | Sqm | 498.75 | 498.75 | 14.4 | False | None | None | False | None | False | 7182.0 | 0 |
| 2807816 | 90436 | None | 11.26.1 V-2 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer- in-Charge. Including with all lead and lifts as per the direction engineer incharge | Sqm | 144.9 | 144.9 | 1028.16 | False | None | None | False | None | False | 148980.384 | 0 |
| 2807817 | 90436 | None | 8.25 V-2 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Including with all lead and lifts as per the direction engineer incharge | Sqm | 143.85 | 143.85 | 529.1 | False | None | None | False | None | False | 76111.035 | 0 |
| 2807818 | 90436 | None | 8.32 V-2 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Including with all lead and lifts as per the direction engineer incharge | Sqm | 163.8 | 163.8 | 726.54 | False | None | None | False | None | False | 119007.252 | 0 |
| 2807819 | 90436 | None | 8.40 V-2 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Including with all lead and lifts as per the direction engineer incharge | Sqm | 120.75 | 120.75 | 89.1 | False | None | None | False | None | False | 10758.825 | 0 |
| 2807820 | 90436 | None | 13.47 V-2 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 75 mm diameter Including with all lead and lifts as per the direction engineer incharge | Rmtr | 206.85 | 206.85 | 68.2 | False | None | None | False | None | False | 14107.17 | 0 |
| 2807821 | 90436 | None | 1.3.1 EL | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 19mm dia 2mm thick | Rmtr | 68.0 | 68.0 | 179.0 | False | None | None | False | None | False | 12172.0 | 0 |
| 2807822 | 90436 | None | 1.3.1 EL | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 25mm dia 2mm thick | Rmtr | 79.0 | 79.0 | 164.0 | False | None | None | False | None | False | 12956.0 | 0 |
| 2807823 | 90436 | None | 1.7.1 EL | Groove cutting Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of conduit/GI pipe and plastering, finishing upto wall surface complete. upto 50 mm conduit in brick wall | Rmtr | 29.0 | 29.0 | 318.0 | False | None | None | False | None | False | 9222.0 | 0 |
| 2807824 | 90436 | None | 1.4 EL | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.135 x 75 x 65 mm | Each | 139.0 | 139.0 | 10.0 | False | None | None | False | None | False | 1390.0 | 0 |
| 2807825 | 90436 | None | 1.4 EL | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 200 x 200 x 65 mm | Each | 348.0 | 348.0 | 5.0 | False | None | None | False | None | False | 1740.0 | 0 |
| 2807826 | 90436 | None | 1.5 EL | Supplying and fixing PVC/metal conduit Deep junction box 19/20 mm deep Junction box | Each | 49.0 | 49.0 | 20.0 | False | None | None | False | None | False | 980.0 | 0 |
| 2807827 | 90436 | None | 1.5 EL | Supplying and fixing PVC/metal conduit Deep junction box 25 mm deep Junction box | Each | 56.0 | 56.0 | 20.0 | False | None | None | False | None | False | 1120.0 | 0 |
| 2807828 | 90436 | None | 1.11 EL | Supplying and Fixing 'S' Hook made out of 14mm dia M.S.Rod | Rmtr | 52.0 | 52.0 | 40.0 | False | None | None | False | None | False | 2080.0 | 0 |
| 2807829 | 90436 | None | 2.1.1 EL | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm 2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3m from tapping point to out let via switch | Point | 285.0 | 285.0 | 16.0 | False | None | None | False | None | False | 4560.0 | 0 |
| 2807830 | 90436 | None | 3.5.1 EL | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 1 to 3 Module | Each | 137.0 | 137.0 | 20.0 | False | None | None | False | None | False | 2740.0 | 0 |
| 2807831 | 90436 | None | 3.5.1 EL | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 6 Module | Each | 234.0 | 234.0 | 10.0 | False | None | None | False | None | False | 2340.0 | 0 |
| 2807832 | 90436 | None | 3.4 EL | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-3 Way | Each | 138.0 | 138.0 | 6.0 | False | None | None | False | None | False | 828.0 | 0 |
| 2807833 | 90436 | None | 3.4 EL | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6 Way | Each | 220.0 | 220.0 | 15.0 | False | None | None | False | None | False | 3300.0 | 0 |
| 2807834 | 90436 | None | 3.6.1 EL | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6A One Way Switch | Each | 102.0 | 102.0 | 14.0 | False | None | None | False | None | False | 1428.0 | 0 |
| 2807835 | 90436 | None | 3.6.1 EL | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6A Two Way Switch | Each | 166.0 | 166.0 | 14.0 | False | None | None | False | None | False | 2324.0 | 0 |
| 2807836 | 90436 | None | 3.6.1 EL | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6A Stepped Fan Regulator Two Module | Each | 357.0 | 357.0 | 6.0 | False | None | None | False | None | False | 2142.0 | 0 |
| 2807837 | 90436 | None | 3.6.1 EL | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6A TV/Telephone Socket | Each | 156.0 | 156.0 | 5.0 | False | None | None | False | None | False | 780.0 | 0 |
| 2807838 | 90436 | None | 3.7 EL | Supplying and fixing 32A security and energy saving DP switch with key tag suitable to operate on 230 V, 50Hz AC supply & completely wired on existing box. | Each | 646.0 | 646.0 | 3.0 | False | None | None | False | None | False | 1938.0 | 0 |
| 2807839 | 90436 | None | 3.8 EL | Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screws. | Sq CM | 0.41 | 0.41 | 40.0 | False | None | None | False | None | False | 16.4 | 0 |
| 2807840 | 90436 | None | 3.1.2 EL | Supplying ......way plastic gang box and fixing using necessary wooden/ rawl/phill plugs and screws. 1 Way Gang Box | Each | 23.0 | 23.0 | 10.0 | False | None | None | False | None | False | 230.0 | 0 |
| 2807841 | 90436 | None | 3.1.2 EL | Supplying ......way plastic gang box and fixing using necessary wooden/ rawl/phill plugs and screws. 2 to 4 Way Gang Box | Each | 32.0 | 32.0 | 10.0 | False | None | None | False | None | False | 320.0 | 0 |
| 2807842 | 90436 | None | 3.1.4 EL | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. | Each | 70.0 | 70.0 | 5.0 | False | None | None | False | None | False | 350.0 | 0 |
| 2807843 | 90436 | None | 5.4.1 EL | Fixing a shunt capacitor of ... kVAR capacity with necessary clA, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor. | Each | 154.0 | 154.0 | 5.0 | False | None | None | False | None | False | 770.0 | 0 |
| 2807844 | 90436 | None | 2.3.1 EL | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.1 mm2 | Mtr | 19.0 | 19.0 | 183.0 | False | None | None | False | None | False | 3477.0 | 0 |
| 2807845 | 90436 | None | 2.3.1 EL | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2 | Mtr | 42.0 | 42.0 | 118.0 | False | None | None | False | None | False | 4956.0 | 0 |
| 2807846 | 90436 | None | 5.6.6 EL | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws 20" x 20" x 2.5" | Each | 326.13 | 326.13 | 5.0 | False | None | None | False | None | False | 1630.65 | 0 |
| 2807847 | 90436 | None | 5.7.1 EL | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 16 Amps | Each | 157.0 | 157.0 | 3.0 | False | None | None | False | None | False | 471.0 | 0 |
| 2807848 | 90436 | None | 5.19.1 EL | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. 4 Way SP & N | Each | 1241.0 | 1241.0 | 3.0 | False | None | None | False | None | False | 3723.0 | 0 |
| 2807849 | 90436 | None | 6.3.1 EL | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48" Sweep (1200 mm) Regular model | Each | 2984.0 | 2984.0 | 10.0 | False | None | None | False | None | False | 29840.0 | 0 |
| 2807850 | 90436 | None | 11.3.1 EL | Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2' - 9/10 W | Each | 551.0 | 551.0 | 15.0 | False | None | None | False | None | False | 8265.0 | 0 |