2814038 | 90746 | None | 001 | Earth work in surface excavation for stripping, seating of bund, Road way by manual means for lowering & levelling the ground for all works other than foundation & depth in Ordinary rock and soft rock upto 300mm depth as per drawing and technical specifications, including setting out, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & tacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.
| Cum | 191.58 | 191.58 | 79.73 | False | None | None | False | None | False | 15274.6734 | 0 |
2814039 | 90746 | None | 002 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates
| Cum | 5362.18 | 5362.18 | 5.34 | False | None | None | False | None | False | 28634.0412 | 0 |
2814040 | 90746 | None | 003 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part-I)-2005 and constructed with CM 1 4 as per IS 2572 2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.
| Sqm | 1092.83 | 1092.83 | 50.26 | False | None | None | False | None | False | 54925.6358 | 0 |
2814041 | 90746 | None | 004 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each eposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m
| Cum | 210.12 | 210.12 | 78.0 | False | None | None | False | None | False | 16389.36 | 0 |
2814042 | 90746 | None | 005 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour, rolling, water, materials, usage & all other appurtenaces required to complete the work
| Cum | 414.06 | 414.06 | 3.888 | False | None | None | False | None | False | 1609.86528 | 0 |
2814043 | 90746 | None | 0006 | Providing 18 mm cement plaster of mix 1 6 (1 cement 6 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in charge. for inside/outside plastering
(18mm in an 1 6) "
| Sqm | 316.21 | 316.21 | 105.0 | False | None | None | False | None | False | 33202.05 | 0 |
2814044 | 90746 | None | 007 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to omplete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately Mix 1 2 4 (M15) Using 20 mm nominal size graded crushed coarse aggregates CC 1 2 4
| Cum | 6056.4 | 6056.4 | 3.2 | False | None | None | False | None | False | 19380.48 | 0 |
2814045 | 90746 | None | 008 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 140.08 | 140.08 | 105.0 | False | None | None | False | None | False | 14708.4 | 0 |
2814046 | 90746 | None | 009 | Providing & fixing 30mm thick factory made rigid foam Panelled Door Shutters made from M.S. tube of 19 gauge thickness, size 19x19mm for stiles and 15x15mm for top & bottom rails, covered with heat moulded PVC C channel of 5mm thick sheet & 30 x 50mm wide to form stiles & 5mm thick & 75mm wide PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet fitted in the M.S. Frame, Sealed to the stiles & rails with 5x30mm PVC sheet beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer in charge fixed to frames with 3 nos of 75 mm Aluminium hinges
| Sqm | 784.86 | 784.86 | 3.0 | False | None | None | False | None | False | 2354.58 | 0 |
2814047 | 90746 | None | 010 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge
| Kg | 140.08 | 140.08 | 179.8 | False | None | None | False | None | False | 25186.384 | 0 |
2814048 | 90746 | None | 011 | Providing & fixing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge 0.63 mm thick with zinc coating not less than 275 g/ m²
| Sqm | 818.85 | 818.85 | 14.04 | False | None | None | False | None | False | 11496.654 | 0 |
2814049 | 90746 | None | 012 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1 4 (1 Cement 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete
| Sqm | 796.19 | 796.19 | 24.75 | False | None | None | False | None | False | 19705.7025 | 0 |
2814050 | 90746 | None | 013 | Electrification, Supplying heavy gauge PVC conduit pipe 25mm dia 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.
| Mtr | 80.0 | 80.0 | 12.0 | False | None | None | False | None | False | 960.0 | 0 |
2814051 | 90746 | None | 014 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or consealed system of wiring with specified IS 694 1990 & confirming to GTP of GROUP A. a) 2.5 sq mm for Lighting Circuit.
| Mtr | 40.0 | 40.0 | 36.0 | False | None | None | False | None | False | 1440.0 | 0 |
2814052 | 90746 | None | 015 | Supplying and wiring adopting loop system in existing PVC Conduit/ casing capping using 1100V grade Copper conductor flexible multistrand FRLS PVC insulated, 2X1.5sqmm cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/ PVC round block. Complete for each outlet. With Switches Short point above Up to 3Mtr from tapping point to out let via switch box.
| Each | 276.0 | 276.0 | 3.0 | False | None | None | False | None | False | 828.0 | 0 |
2814053 | 90746 | None | 016 | Supplying and flush mounting powder coated/Galvanized metal box suitable for mounting modular switch plates, the box should be firmly flush mounted after the gfroocve cutting in brick / stone/CC wall 10 12 Way
| Each | 325.0 | 325.0 | 1.0 | False | None | None | False | None | False | 325.0 | 0 |
2814054 | 90746 | None | 017 | Supplying and fixing superior quality modular switch mounting poly corbonate plate with necessary supporting back plate with required numbers of machine screws, bolts, nuts etc., complete on the existing metal/PVC box.10 12 Module
| Each | 363.0 | 363.0 | 1.0 | False | None | None | False | None | False | 363.0 | 0 |
2814055 | 90746 | None | 018 | Supplying and fixing miniature circuit breakers on existing MCB distributtion boards using necessary fixing materials and 'C' Type curve, indicator ON/ OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 Amps SP
| Each | 523.0 | 523.0 | 1.0 | False | None | None | False | None | False | 523.0 | 0 |
2814056 | 90746 | None | 019 | Suplying and fixing 32 Amps security and energy saving D.P. switch with key tag suitable to operate on 230 Volts, 50Hz AC supply & completely wired on existing box. Group A
| Each | 747.0 | 747.0 | 1.0 | False | None | None | False | None | False | 747.0 | 0 |
2814057 | 90746 | None | 020 | Supplying, fixing, wiring, earth electrode for grounding conduits IC cutouts and other equipments on the meter board using 40mm dia 2.90mm thick GI pipe of 2.50mtr long burried in a pit. The pit should be filled with equal proportion of salt and charcol 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3 of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 122mm dia
| Each | 2999.7 | 2999.7 | 1.0 | False | None | None | False | None | False | 2999.7 | 0 |
2814058 | 90746 | None | 021 | Supplying of 4 ft PVC batten with integrated LED Tube with high quality diffuser with life of 25000 burning hours and 70 % lumin maintenance with CRI less than 80 power input 220 240 V 50/60 HZ & power factor less than 0.90 along with CE approved. 2 years of warrantee against any manufacturing defects working under standard electrical conditions.
| Each | 2999.7 | 2999.7 | 3.0 | False | None | None | False | None | False | 8999.1 | 0 |
2814059 | 90746 | None | 022 | Fixing all types and all capacities of fluorescent/false ceiling /spot light/CFL/LED fittings indoor on the wall/ceiling/rafters/girders using 23/0.0076 twin twisted PVC insulated wires, required Nos of round blocks and clamps On wall/ceiling/Rafter Girders
| Each | 119.0 | 119.0 | 3.0 | False | None | None | False | None | False | 357.0 | 0 |
2814060 | 90746 | None | 023 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper conductor single core wire in open or consealed system of wiring as per IS 694 1990 & confirming to GTP of GROUP B.
1.50 sqmm wire for Earthing "
| Mtr | 26.0 | 26.0 | 15.0 | False | None | None | False | None | False | 390.0 | 0 |
2814061 | 90746 | None | 024 | Supplying and fixing/replacing of 616/32Amps electrical accessories on existing switch board 6Amps SP Switch
| No | 40.0 | 40.0 | 3.0 | False | None | None | False | None | False | 120.0 | 0 |
2814062 | 90746 | None | 025 | Providing CPVC Pipes 25mm dia
| Mtr | 49.35 | 49.35 | 270.0 | False | None | None | False | None | False | 13324.5 | 0 |
2814063 | 90746 | None | 026 | Providing CPVC Pipes 20mm dia.
| Mtr | 45.0 | 45.0 | 60.0 | False | None | None | False | None | False | 2700.0 | 0 |
2814064 | 90746 | None | 027 | Providing and fixing C.P.brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810gm.
| No | 707.7 | 707.7 | 3.0 | False | None | None | False | None | False | 2123.1 | 0 |
2814065 | 90746 | None | 028 | Providing and fixing C.P.brass long nose ball valve of approved quality conforming to IS standards and weighing not less than 810gm.
| No | 680.0 | 680.0 | 12.0 | False | None | None | False | None | False | 8160.0 | 0 |
2814066 | 90746 | None | 0029 | White Vitreous China Wash basin size 630x450 mm with a single 15mm C.P. brass pillar tap.
| No | 2220.68 | 2220.68 | 2.0 | False | None | None | False | None | False | 4441.36 | 0 |
2814067 | 90746 | None | 030 | Mirror 600x450mm bevel lead edge Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
| Unit | 1000.13 | 1000.13 | 2.0 | False | None | None | False | None | False | 2000.26 | 0 |
2814068 | 90746 | None | 031 | Providing and fixing TMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88mm, weighing not less than 190g
| Unit | 391.4 | 391.4 | 2.0 | False | None | None | False | None | False | 782.8 | 0 |
2814069 | 90746 | None | 032 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid
| Each | 5155.15 | 5155.15 | 1.0 | False | None | None | False | None | False | 5155.15 | 0 |
2814070 | 90746 | None | 033 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
| Each | 4373.38 | 4373.38 | 1.0 | False | None | None | False | None | False | 4373.38 | 0 |
2814071 | 90746 | None | 034 | Constructing brick masonry chamber of internal dimension 450x450mm. and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1 6, bed concrete 150mm thick with 1 3 6, plastering 12 mm thick with cement mortar 1 4, CC 1 2 4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.
| No | 3979.92 | 3979.92 | 3.0 | False | None | None | False | None | False | 11939.76 | 0 |
2814072 | 90746 | None | 035 | Supplying PVC ringtite pipes conforming to IS 4985 2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for PVC pipes 110mm dia., 6 kg/sqcm & class 3.
| Mtr | 405.82 | 405.82 | 12.0 | False | None | None | False | None | False | 4869.84 | 0 |
2814073 | 90746 | None | 036 | Supplying PVC ringtite pipes conforming to IS 4985 2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for PVC pipe, 75mm dia pipe for Air pipe,
| Mtr | 216.3 | 216.3 | 6.0 | False | None | None | False | None | False | 1297.8 | 0 |
2814074 | 90746 | None | 037 | Supplying S & S RCC SPUN/VIBRATED CAST PIPES (REINFORCED) pipes NP-3 Class conforming to IS 458 1988 with latest amentments using ordinary portland cement, for sanitary works and conveying to work site, rolling and lowering into trenches, laying true to line and level including loading and unloading at both destinations and jointing of pipes and specials, perfect linking of joints with jack to correct position including cost of jointing materials, i.e, rubber rings conforming to IS 5382 for S&S RCC pipes, with all leads and lifts as directed and giving necessary hydraulic test as per ISS to the required pressure and commissioning etc. complete. (Contractor will make his own arrangements for procuring water for testing). Before the execution of the work, the contractor shall carry out the survey. Rings 1.20m Dia. for Soak pit
| Mtr | 7425.27 | 7425.27 | 2.1 | False | None | None | False | None | False | 15593.067 | 0 |
2814075 | 90746 | None | 038 | Providing 10cms thick RCC Lid over soak pit
| No | 1200.0 | 1200.0 | 1.0 | False | None | None | False | None | False | 1200.0 | 0 |