| 1709028178000 | 0 | None | None | Buildings | Construction of Classroom at Govt Advanced HPS Echagatta, in Davanagere taluk (Mayakonda Constituency) | 817419.12 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 2823743 | 91270 | None | 1.13 V-I | Earth work in surface excavation by mechanical means for lowering & leveling the ground without blasting for all works other than foundation in Ordinary/Soft rock & depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work with all lead and lifts as per the direction of engineer in charge | Cum | 362.0 | 362.0 | 12.75 | False | None | None | False | None | False | 4615.5 | 0 | | 2823744 | 91270 | None | 1.15.1 V-I | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth with all lead and lifts as per the direction of engineer in charge | Cum | 363.0 | 363.0 | 20.66 | False | None | None | False | None | False | 7499.58 | 0 | | 2823745 | 91270 | None | 1.23 V-I | Providing and Filling in foundation with granite / trap broken metal 100mm. and down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications. with all lead and lifts as per the direction of engineer in charge | Cum | 2682.0 | 2682.0 | 2.33 | False | None | None | False | None | False | 6249.06 | 0 | | 2823746 | 91270 | None | 2.1.2 V-I | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates with all lead and lifts as per the direction of engineer in charge | Cum | 5664.0 | 5664.0 | 8.41 | False | None | None | False | None | False | 47634.24 | 0 | | 2823747 | 91270 | None | 5.2 V-II | Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) with all lead and lifts as per the direction of engineer in charge | Cum | 6618.0 | 6618.0 | 5.54 | False | None | None | False | None | False | 36663.72 | 0 | | 2823748 | 91270 | None | 8.19.2 V-II | Providing Raised and cut pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge. with all lead and lifts as per the direction of engineer in charge | Cum | 463.0 | 463.0 | 14.92 | False | None | None | False | None | False | 6907.96 | 0 | | 2823749 | 91270 | None | 2.2.1 V-I | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all lead and lifts as per the direction of engineer in charge | Cum | 6789.96 | 6789.96 | 2.7 | False | None | None | False | None | False | 18332.892 | 0 | | 2823750 | 91270 | None | 2.3.1 V-I | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all lead and lifts as per the direction of engineer in charge | Cum | 9484.5 | 9484.5 | 1.92 | False | None | None | False | None | False | 18210.24 | 0 | | 2823751 | 91270 | None | 2.5.1 V-I | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all lead and lifts as per the direction of engineer in charge | Cum | 11271.0 | 11271.0 | 1.47 | False | None | None | False | None | False | 16568.37 | 0 | | 2823752 | 91270 | None | 2.5.1 V-I | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all lead and lifts as per the direction of engineer in charge | Cum | 6630.0 | 6630.0 | 0.22 | False | None | None | False | None | False | 1458.6 | 0 | | 2823753 | 91270 | None | 2.5.1 V-I | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all lead and lifts as per the direction of engineer in charge | Cum | 10608.0 | 10608.0 | 4.37 | False | None | None | False | None | False | 46356.96 | 0 | | 2823754 | 91270 | None | 2.5.1 V-I | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all lead and lifts as per the direction of engineer in charge | Cum | 9945.0 | 9945.0 | 8.84 | False | None | None | False | None | False | 87913.8 | 0 | | 2823755 | 91270 | None | 2.5.1 V-I | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all lead and lifts as per the direction of engineer in charge | Cum | 9613.5 | 9613.5 | 0.42 | False | None | None | False | None | False | 4037.67 | 0 | | 2823756 | 91270 | None | 1.9 V-I | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. with all lead and lifts as per the direction of engineer in charge | Cum | 266.0 | 266.0 | 22.47 | False | None | None | False | None | False | 5977.02 | 0 | | 2823757 | 91270 | None | 6.7 V-II | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in super structure above plinth in shape and sizes Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. with all lead and lifts as per the direction of engineer in charge | Cum | 8211.0 | 8211.0 | 13.5 | False | None | None | False | None | False | 110848.5 | 0 | | 2823758 | 91270 | None | 2.11a V-I | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specificationAll other type of structures with all lead and lifts as per the direction of engineer in charge | Tonne | 89457.0 | 89457.0 | 1.6 | False | None | None | False | None | False | 143131.2 | 0 | | 2823759 | 91270 | None | 11.5.1 V-II | Providing and fixing 1mm thick MS sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete including applying a priming coat a of approved steel primer, using M.S. angels 40x40x6mm for diagonal braces. with all lead and lifts as per the direction of engineer in charge | Sqm | 4478.0 | 4478.0 | 2.52 | False | None | None | False | None | False | 11284.56 | 0 | | 2823760 | 91270 | None | 11.15.1 V-II | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenonedand riveted, including providing and fixing of hinges, pivots, includingpriming coat of approved steel primer, but excluding the cost of otherfittings, complete all as per approved design, (sectional weight of onlysteel members shall be measured for payment). Fixing with carbon steelgalvanised dash fastener of required dia and size (to be paid for separately)including cost of materials, labour, usage charges of machinery completeas per specifications and as per directions of the Engineer-in-Charge.. with all lead and lifts as per the direction of engineer in charge | Kg | 107.0 | 107.0 | 151.2 | False | None | None | False | None | False | 16178.4 | 0 | | 2823761 | 91270 | None | 2.3.1 V-I | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications with all lead and lifts as per the direction of engineer in charge | Cum | 6323.0 | 6323.0 | 0.66 | False | None | None | False | None | False | 4173.18 | 0 | | 2823762 | 91270 | None | 8.5.2 V-II | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. with all lead and lifts as per the direction of engineer in charge | Sqm | 349.0 | 349.0 | 144.69 | False | None | None | False | None | False | 50496.81 | 0 | | 2823763 | 91270 | None | 9.17.2 V-II | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete..Size of Tile 600x600 mm with all lead and lifts as per the direction of engineer in charge | Sqm | 1175.0 | 1175.0 | 53.15 | False | None | None | False | None | False | 62451.25 | 0 | | 2823764 | 91270 | None | 11.28 V-II | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, with all lead and lifts as per the direction of engineer in charge with all lead and lifts as per the direction of engineer in charge | Kg | 565.0 | 565.0 | 40.47 | False | None | None | False | None | False | 22865.55 | 0 | | 2823765 | 91270 | None | 8.25 V-II | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. with all lead and lifts as per the direction of engineer in charge | Sqm | 137.0 | 137.0 | 118.6 | False | None | None | False | None | False | 16248.2 | 0 | | 2823766 | 91270 | None | 8.31 V-II | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. with all lead and lifts as per the direction of engineer in charge | Sqm | 178.0 | 178.0 | 95.67 | False | None | None | False | None | False | 17029.26 | 0 | | 2823767 | 91270 | None | 8.51 V-II | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 100.0 | 100.0 | 118.6 | False | None | None | False | None | False | 11860.0 | 0 | | 2823768 | 91270 | None | 8.40 V-II | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 115.0 | 115.0 | 15.04 | False | None | None | False | None | False | 1729.6 | 0 | | 2823769 | 91270 | None | 10.14.9 V-V | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges,handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. 75mm ( weight of pipe -0.917 kg) | Rmtr | 192.0 | 192.0 | 20.0 | False | None | None | False | None | False | 3840.0 | 0 | | 2823770 | 91270 | None | 8.84 V-II | Providing wall black boards in CM 1:3 with two coats of black paint including finishing etc., complete. Shivamogga | Sqm | 475.0 | 475.0 | 2.0 | False | None | None | False | None | False | 950.0 | 0 | | 2823771 | 91270 | None | 11.47 V-II | Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete including cost of materials, labour, usage charges of machinery complete as per specifications. | Nos | 437.0 | 437.0 | 2.0 | False | None | None | False | None | False | 874.0 | 0 | | 2823772 | 91270 | None | 20.26 V-II | Providing and fixing bright finished brass double acting spring hinges with necessary brass screws etc. complete : | Each | 732.0 | 732.0 | 6.0 | False | None | None | False | None | False | 4392.0 | 0 | | 2823773 | 91270 | None | 12.63 V-II | Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete | Nos | 130.0 | 130.0 | 20.0 | False | None | None | False | None | False | 2600.0 | 0 | | 2823774 | 91270 | None | 1.1.1 PWD ELE V-VI | Supplying heavy gauge PVC conduit pipe 19/20 mm dia 2 mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste, etc & fixing using inverted wood plugs in case of RCC ceiling wall & RCC wall/stone structure or rawl plugs in case of brick walls & cement plastering damaged portion using heavy gauge saddles at an interval of 700 mm using NF screws Electical works | m | 69.0 | 69.0 | 60.0 | False | None | None | False | None | False | 4140.0 | 0 | | 2823775 | 91270 | None | 1.9.1 PWD ELE V-VI | Supplying PVC/GI flexible conduit pipe 20 mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely | m | 19.0 | 19.0 | 60.0 | False | None | None | False | None | False | 1140.0 | 0 | | 2823776 | 91270 | None | 2.3.2 PWD ELE V-VI | Wiring for lighting/power circuit using one of PVC insulated 1100v grade,multistrand copper wire with low conducteer resistance single core in open or concealed system of wiring with specifiedIS-694. 1.5 Sqm | m | 26.0 | 26.0 | 60.0 | False | None | None | False | None | False | 1560.0 | 0 | | 2823777 | 91270 | None | 2.3.2 PWD ELE V-VI | Wiring for lighting/power circuit using one of PVC insulated 1100v grade,multistrand copper wire with low conducteer resistance single core in open or concealed system of wiring with specifiedIS-694. 2.5 Sqm | m | 42.0 | 42.0 | 50.0 | False | None | None | False | None | False | 2100.0 | 0 | | 2823778 | 91270 | None | 2.3.2 PWD ELE V-VI | Wiring for lighting/power circuit using one of PVC insulated 1100v grade,multistrand copper wire with low conducteer resistance single core in open or concealed system of wiring with specifiedIS-694. 14 Sqm | m | 63.0 | 63.0 | 20.0 | False | None | None | False | None | False | 1260.0 | 0 | | 2823779 | 91270 | None | 1.7.1 PWD ELE V-VI | Groove cutting in brick wall/CC floor to the siutable depth for concealing of conduit pipe and plastering finishing the wall upto wall surface complete. Electical works | m | 29.0 | 29.0 | 75.0 | False | None | None | False | None | False | 2175.0 | 0 | | 2823780 | 91270 | None | 2.1 PWD ELE V-VI | Supplying & wiring adopting loop system in existing PVC conduit/casing capping using 1100V grade, copper conductor flexible multistrand FRLS PVC insulated to 2x1.5 sqmm cable confirming to the GTP with 6amps flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. Electical works Short point up to 3.0 mtr from tapping point to outlet via switch | Point | 285.0 | 285.0 | 4.0 | False | None | None | False | None | False | 1140.0 | 0 | | 2823781 | 91270 | None | 2.1 PWD ELE V-VI | Medium point above 3.0 mtr upto 6.0 mtr from tapping point to outlet via switch | Point | 394.0 | 394.0 | 4.0 | False | None | None | False | None | False | 1576.0 | 0 | | 2823782 | 91270 | None | 2.1 PWD ELE V-VI | Long point above 6.0 mtr upto 10.0 mtr from tapping point to outlet via switch | Point | 570.0 | 570.0 | 4.0 | False | None | None | False | None | False | 2280.0 | 0 | | 2823783 | 91270 | None | 3.8 PWD ELE V-VI | Supplying 4 mm thick plastic sheet with necessary nitches for fixing switches regulators etc, & fixing on existing wooden or metal box using NF screws. Electical works | Sq CM | 0.41 | 0.41 | 2700.0 | False | None | None | False | None | False | 1107.0 | 0 | | 2823784 | 91270 | None | 3.14.1 PWD ELE V-VI | Supplying & fixing/replacing of 6/16/32 amps electrical accessories on existing switch board Group-A Electical works 6 amps SP switches | Nos | 55.0 | 55.0 | 8.0 | False | None | None | False | None | False | 440.0 | 0 | | 2823785 | 91270 | None | 3.14.1 PWD ELE V-VI | 6 amps 3 way 5 pin socket | Nos | 70.0 | 70.0 | 3.0 | False | None | None | False | None | False | 210.0 | 0 | | 2823786 | 91270 | None | 6.3.1 PWD ELE V-VI | Supplying & fixing capacitor type ceiling Fan complete with down rod blades, shackle, canopies for operation on 230 volts, 50 cycles. Single phase AC supplyin confirming to ISS-374-1979 & with double ball bearing Economy model. | Nos | 2984.0 | 2984.0 | 2.0 | False | None | None | False | None | False | 5968.0 | 0 | | 2823787 | 91270 | None | 5.19.1 PWD ELE V-VI | Supplying fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts eith provission for fixing suitable type capacity MCB's single phase / 3 phase / single door double coated painting Group-A | Nos | 1241.0 | 1241.0 | 1.0 | False | None | None | False | None | False | 1241.0 | 0 | | 2823788 | 91270 | None | 11.11.7 PWD ELE V-VI | Supplying & fixing of retrofit type-LED bulb......Wwith OPAL acrylic diffuser comprising of LED source with CCT 6500 degreeK, CRI70%.efficacy80lumenperW,life25000 burning hours and Compliance toIS10322/IEC60598,LM79&LM80.TheLEDaredrivenbyHFelectronicdriverintegratedinthesystem,withPF0.95,powerlossshould5%oflampWage.,shortcircuit&opencircuitprotectiontobeintegratedinthecircuit,THDlessthan20%,LifeasperLM79.Theoperatinginputvoltageshouldbebetween130to275V.BISApprovedandTestedbyNABL/CPRIaccreditedlaboratorywith2yearsWarrantyagainstanymanufacturing defect working under standard electrical condition.18W, 6500K | Nos | 426.0 | 426.0 | 4.0 | False | None | None | False | None | False | 1704.0 | 0 |
|