2827073 | 91445 | None | code01 | BOREWELL: Geophysical investigation at site for sinking borewells for supplying drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner orSchlumbergers’s method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test,Complete as per specification and as per the direction of the engineer-in-charge of work. | No | 5288.0 | 5288.0 | 1.0 | False | None | None | False | None | False | 5288.0 | 0 |
2827074 | 91445 | None | code02 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) 0 - 50.00 Mtrs,Complete as per specification and as per the direction of the engineer-in-charge of work. | m | 407.0 | 407.0 | 50.0 | False | None | None | False | None | False | 20350.0 | 0 |
2827075 | 91445 | None | code02a | 50.00 - 100.00 Mtrs | m | 510.4 | 510.4 | 50.0 | False | None | None | False | None | False | 25520.0 | 0 |
2827076 | 91445 | None | code02b | 100.00 - 150.00 Mtrs | m | 542.3 | 542.3 | 50.0 | False | None | None | False | None | False | 27115.0 | 0 |
2827077 | 91445 | None | code02c | 150.00 - 200.00 Mtrs | m | 629.2 | 629.2 | 50.0 | False | None | None | False | None | False | 31460.0 | 0 |
2827078 | 91445 | None | code02d | 200.00 - 250.00 Mtrs | m | 738.1 | 738.1 | 50.0 | False | None | None | False | None | False | 36905.0 | 0 |
2827079 | 91445 | None | code02e | 250.00 - 300.00 Mtrs | m | 814.0 | 814.0 | 50.0 | False | None | None | False | None | False | 40700.0 | 0 |
2827080 | 91445 | None | code02f | 300.00 - 350.00 Mtrs | m | 954.8 | 954.8 | 50.0 | False | None | None | False | None | False | 47740.0 | 0 |
2827081 | 91445 | None | code03 | Suppling of ISI mark 175 mm nominal bore plain end steel casing pipe - grade of steel Fe 410 of wall thickness 5.4 mm thick confining to IS 4270:2001 and latest amendments electric resistance welded steel tube material and confirming to IS 1387 / 1993 & manufactured by basic open hearth electric or basic oxygen process in random length of 4 to 7 mts. Both ends threaded confinming to IS 554 / 1985, one end fixed with a socket confirming to IS 4270:2001 and the other end with screwed pipes. All pipes shall be resonably free from defects. the tubes shall be reasonably straight should be with ISI marking, weighing 25.10 kg/mtr (inclusive of all taxes and duties) prices include coller medium duty. Complete as per specification and as per the direction of the engineer-in-charge of work. | m | 2126.3 | 2126.3 | 15.0 | False | None | None | False | None | False | 31894.5 | 0 |
2827082 | 91445 | None | code04 | Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments | Each | 165.0 | 165.0 | 1.0 | False | None | None | False | None | False | 165.0 | 0 |
2827083 | 91445 | None | code05 | providing and laying at site of work MS casing caps as per IS 1239 (part II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and olars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge.Complete as per specification and as per the direction of the engineer-in-charge of work. | No | 180.4 | 180.4 | 1.0 | False | None | None | False | None | False | 180.4 | 0 |
2827084 | 91445 | None | code06 | Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic | Mtr | 1695.1 | 1695.1 | 15.0 | False | None | None | False | None | False | 25426.5 | 0 |
2827085 | 91445 | None | code07 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.Complete as per specification and as per the direction of the engineer-in-charge of work. | Each | 5999.4 | 5999.4 | 1.0 | False | None | None | False | None | False | 5999.4 | 0 |
2827086 | 91445 | None | code08 | Supply and delivery at site brand new submersible pumpset suitable for borewell of 150 mm dia and having the declared duty conditions as detailed below and satisfying performance characteristics for pump and motor as declared by the bureau of Indian stand. thd pumpset should conform to IS : 8034 - 1989 (with all its latest amendments) and should bear ISI certification mark IS: 8034-1989 Submercible Pumpset 20 HP 20 stages- Texmo/Taro or equalents Brands ,Complete as per specification and as per the direction of the engineer-in-charge of work. | No | 89199.0 | 89199.0 | 1.0 | False | None | None | False | None | False | 89199.0 | 0 |
2827087 | 91445 | None | code09 | Submersible Cable:- Supply of delivery brand new best make PVC insulated cable of flat 3 core (seated) of nominal cross section area confirm in to IS 694/90/ with latest amendment and ISI mark. Finolex/ equalent brand. 1 x 3 x 4 sqmm cable. | Sqm | 148.5 | 148.5 | 700.0 | False | None | None | False | None | False | 103950.0 | 0 |
2827088 | 91445 | None | code10 | Supply and delivery of galvanized mild steel tubes of 6mtr standard length heavy duty (C Class) as per IS 1239 (Part-I) 1990 with latest amendments with ISI Mark (one end fitted with Heavy Duty collar and other end fitted with protective cover) ,50 mm.Complete as per specification and as per the direction of the engineer-in-charge of work. | Each | 3355.0 | 3355.0 | 58.0 | False | None | None | False | None | False | 194590.0 | 0 |
2827089 | 91445 | None | code11 | Supply and delivery at site of brand new best make gate valve as per IS 778/1984 with ISI Mark and as per its latest amendments.50 MM SIZE.complete as per the specification engineer in charge of work | Each | 1375.0 | 1375.0 | 6.0 | False | None | None | False | None | False | 8250.0 | 0 |
2827090 | 91445 | None | code12 | PSupply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments as per specifications. 50 MM SIZE,Complete as per specification and as per the direction of the engineer-in-charge of work. | Each | 1375.0 | 1375.0 | 1.0 | False | None | None | False | None | False | 1375.0 | 0 |
2827091 | 91445 | None | code13 | Providing and fixing in position brass gate valve with C.I wheel of approved quality ( screwed end ) 50mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. Specification No.Complete as per specification and as per the direction of the engineer-in-charge of work. | No | 940.5 | 940.5 | 6.0 | False | None | None | False | None | False | 5643.0 | 0 |
2827092 | 91445 | None | code14 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase elector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL Direct Online Starter 2) S-D- Star Delta Starter.Complete as per specification and as per the direction of the engineer-in-charge of work. | No | 17490.0 | 17490.0 | 1.0 | False | None | None | False | None | False | 17490.0 | 0 |
2827093 | 91445 | None | code15 | Supply and fixing HRC fuse units base on existing switch/ panel board 32 to 63 Amps.Complete as per specification and as per the direction of the engineer-in-charge of work. | No | 612.0 | 612.0 | 1.0 | False | None | None | False | None | False | 612.0 | 0 |
2827094 | 91445 | None | code16 | Supply and delivery at site delivery of best indigenous brand new MCB (Miniature Circuit Breakers) of required capacity as per IS 88228/1978 and its latest amendments and with ISI Mark of 6/10/16/20/25/40 Amps
with scalable box.Complete as per specification and as per the direction of the engineer-in-charge of work. | No | 1265.0 | 1265.0 | 1.0 | False | None | None | False | None | False | 1265.0 | 0 |
2827095 | 91445 | None | code17 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides made out of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs, screws etc., (20'x20"x2.5").Complete as per specification and as per the direction of the engineer-in-charge of work. | No | 326.13 | 326.13 | 1.0 | False | None | None | False | None | False | 326.13 | 0 |
2827096 | 91445 | None | code18 | Supplying and fixing and wiring heavy duty low voltage capacitors conforming to IS 2834, 3 phase 400/440 volts grade, for power factor improvement of rotating machinery, cost per KVAR (b) group B. Complete as per specification and as per the direction of the engineer-in-charge of work. | Kvar | 480.0 | 480.0 | 1.0 | False | None | None | False | None | False | 480.0 | 0 |
2827097 | 91445 | None | code19 | Supply and laying of LG UT cable having aluminium conductor PVC insulated, sheathed, galvanized steel wire / steel tap armored cable with PVC over sheathing.Complete as per specification and as per the direction of the engineer-in-charge of work. | Mtr | 88.0 | 88.0 | 15.0 | False | None | None | False | None | False | 1320.0 | 0 |
2827098 | 91445 | None | code20 | Erection, electrification and commissioning of pumpset/ submersible pump including aligning and balancing with all necessary erection material and labour including supply and fitting of two pairs of supporting clamps with necessary bolts and washers, one bore well cap, cable clips and watertight gland cable protectors, bolts, nuts, valves and gauges et., involved in the job. Complete as per specification and as per the direction of the engineer-in-charge of work. | Job | 7150.0 | 7150.0 | 1.0 | False | None | None | False | None | False | 7150.0 | 0 |
2827099 | 91445 | None | code21 | Supplying, fixing, wiring earth electrode for grounding conducts, I.C. cutouts and other equipments on the meter board using 40mm dia 2.9 mm thick GI pipe 2.5M long buried in a pit. The pit should be filled with equal proportion of salt and charcoal 150 mm alround the pipe to complete depth. the connection from the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3 of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc. The pipe shall have 16 through holes of 12 mm dia.Complete as per specification and as per the direction of the engineer-in-charge of work. | Per Job | 4125.0 | 4125.0 | 1.0 | False | None | None | False | None | False | 4125.0 | 0 |
2827100 | 91445 | None | code22 | Labour Charges ofr laying of 1.1KV class UG cable when supplied agency in existing trench GI pipe/stone ware pipe/ on wall/ on pole as required. In existing trench/ducts 6 sqmm to 16 sqmm. Complete as per specification and as per the direction of the engineer-in-charge of work. | Mtr | 11.88 | 11.88 | 15.0 | False | None | None | False | None | False | 178.2 | 0 |
2827101 | 91445 | None | code23 | Digging of trench of 0.6m deep x 0.50mtr dua wide refilling the trench to the required ground level and consolidating etc., complete (As per Civil KSRB 1/2 P-7) in Ordinary soil. Complete as per specification and as per the direction of the engineer-in-charge of work. | Rmtr | 76.0 | 76.0 | 30.0 | False | None | None | False | None | False | 2280.0 | 0 |
2827102 | 91445 | None | code24 | RISING MAIN:Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. Complete as per specification and as per the direction of the engineer-in-charge of work. | Cum | 532.4 | 532.4 | 9.0 | False | None | None | False | None | False | 4791.6 | 0 |
2827103 | 91445 | None | code25 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete.-- 50mm nominal OD pipes .Complete as per specification and as per the direction of the engineer-in-charge of work. | m | 793.1 | 793.1 | 25.0 | False | None | None | False | None | False | 19827.5 | 0 |
2827104 | 91445 | None | code26 | Refilling available earth around pipe lines, cables in layers not exceeding 20cms in depth, compacting each deposited layer by ramming after watering with lead upto 50m. and lift upto 1.5 m. including cost of all labour complete as per specifications .Complete as per specification and as per the direction of the engineer-in-charge of work. | Cum | 176.0 | 176.0 | 9.0 | False | None | None | False | None | False | 1584.0 | 0 |
2827105 | 91445 | None | code27 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesComplete as per specification and as per the direction of the engineer-in-charge of work. | Cum | 6587.9 | 6587.9 | 2.25 | False | None | None | False | None | False | 14822.775 | 0 |
2827106 | 91445 | None | code28 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Complete as per specification and as per the direction of the engineer-in-charge of work. | Cum | 6955.3 | 6955.3 | 2.25 | False | None | None | False | None | False | 15649.425 | 0 |
2827107 | 91445 | None | code29 | C C DRAIN:
Earth work excavation by manual means for drains,canals, waste weir,draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.In all kinds of soils Depth upto 1.5 m | Cum | 266.2 | 266.2 | 89.7 | False | None | None | False | None | False | 23878.14 | 0 |
2827108 | 91445 | None | code30 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 521.4 | 521.4 | 239.2 | False | None | None | False | None | False | 124718.88 | 0 |
2827109 | 91445 | None | code31 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m | Cum | 292.6 | 292.6 | 89.7 | False | None | None | False | None | False | 26246.22 | 0 |
2827110 | 91445 | None | code32 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6587.9 | 6587.9 | 10.76 | False | None | None | False | None | False | 70885.804 | 0 |
2827111 | 91445 | None | code33 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7271.45 | 7271.45 | 20.86 | False | None | None | False | None | False | 151682.447 | 0 |
2827112 | 91445 | None | code34 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | Kgs | 86.91 | 86.91 | 1355.59 | False | None | None | False | None | False | 117814.3269 | 0 |
2827113 | 91445 | None | code35 | Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) | Mtr | 333.3 | 333.3 | 89.7 | False | None | None | False | None | False | 29897.01 | 0 |
2827114 | 91445 | None | code36 | roviding and laying 100mm thick pre-cast cover slabs over Road side drains / utility ducts / Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 550 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drain age of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. | Sqm | 1287.0 | 1287.0 | 90.2 | False | None | None | False | None | False | 116087.4 | 0 |
2827115 | 91445 | None | code37 | Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces | Sqm | 119.9 | 119.9 | 89.7 | False | None | None | False | None | False | 10755.03 | 0 |
2827116 | 91445 | None | code38 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation,making coving at Junction, Bore Packing, treatment of construction joints completely as per specification.. | Sqm | 898.7 | 898.7 | 323.55 | False | None | None | False | None | False | 290774.385 | 0 |
2827117 | 91445 | None | code39 | VITRIFIED TILES AND WALL TILES: Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. a) GROUND FLOOR | Sqm | 1259.5 | 1259.5 | 401.18 | False | None | None | False | None | False | 505286.21 | 0 |
2827118 | 91445 | None | code40 | First Floor | Sqm | 1272.1 | 1272.1 | 401.18 | False | None | None | False | None | False | 510341.078 | 0 |
2827119 | 91445 | None | code41 | second Floor | Sqm | 1284.69 | 1284.69 | 401.18 | False | None | None | False | None | False | 515391.9342 | 0 |
2827120 | 91445 | None | code42 | Third Floor | Sqm | 1297.29 | 1297.29 | 347.62 | False | None | None | False | None | False | 450963.9498 | 0 |
2827121 | 91445 | None | code43 | Fourth Floor | Sqm | 1309.88 | 1309.88 | 347.62 | False | None | None | False | None | False | 455340.4856 | 0 |
2827122 | 91445 | None | code44 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.. | Sqm | 1183.6 | 1183.6 | 264.95 | False | None | None | False | None | False | 313594.82 | 0 |
2827123 | 91445 | None | code45 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. | Sqm | 1593.9 | 1593.9 | 1152.56 | False | None | None | False | None | False | 1837065.384 | 0 |
2827124 | 91445 | None | code46 | Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. | Sqm | 880.0 | 880.0 | 52.63 | False | None | None | False | None | False | 46314.4 | 0 |
2827125 | 91445 | None | code47 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer | Kgs | 151.8 | 151.8 | 3602.4 | False | None | None | False | None | False | 546844.32 | 0 |
2827126 | 91445 | None | code48 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 183.7 | 183.7 | 189.6 | False | None | None | False | None | False | 34829.52 | 0 |
2827127 | 91445 | None | code49 | ELECTRICAL WORK: Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. | Each | 241.0 | 241.0 | 37.0 | False | None | None | False | None | False | 8917.0 | 0 |
2827128 | 91445 | None | code50 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 | Each | 739.0 | 739.0 | 37.0 | False | None | None | False | None | False | 27343.0 | 0 |
2827129 | 91445 | None | code51 | Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparentPolycarbonate Lid, shock proof, IP65 (Weather Proof),rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout withsuitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility.
Panel board 300mm x 450mm x 214mm | Each | 6163.0 | 6163.0 | 40.0 | False | None | None | False | None | False | 246520.0 | 0 |
2827130 | 91445 | None | code52 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.. | Cum | 522.72 | 522.72 | 7.56 | False | None | None | False | None | False | 3951.7632 | 0 |
2827131 | 91445 | None | code53 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 3.5 core 35 sqmm | Mtr | 225.0 | 225.0 | 168.0 | False | None | None | False | None | False | 37800.0 | 0 |
2827132 | 91445 | None | code54 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m | Cum | 292.6 | 292.6 | 7.56 | False | None | None | False | None | False | 2212.056 | 0 |
2827133 | 91445 | None | code55 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) 1:4:8 | Cum | 6230.4 | 6230.4 | 5.68 | False | None | None | False | None | False | 35388.672 | 0 |
2827134 | 91445 | None | code56 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) | Cum | 6915.7 | 6915.7 | 3.78 | False | None | None | False | None | False | 26141.346 | 0 |
2827135 | 91445 | None | code57 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding) | Sqm | 184.8 | 184.8 | 4001.25 | False | None | None | False | None | False | 739431.0 | 0 |
2827136 | 91445 | None | code58 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directionsof Engineer-in-charge. | Sqm | 183.7 | 183.7 | 266.75 | False | None | None | False | None | False | 49001.975 | 0 |
2827137 | 91445 | None | code59 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts | Nos | 4256.0 | 4256.0 | 20.0 | False | None | None | False | None | False | 85120.0 | 0 |
2827138 | 91445 | None | code60 | GI/Copper strips for grounding connections, using necessary fixing materials as required. | Mtr | 128.0 | 128.0 | 20.0 | False | None | None | False | None | False | 2560.0 | 0 |
2827139 | 91445 | None | code61 | Wiring for lighting/power circuit using one of FRLS PVCinsulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments 4sqmm | Mtr | 63.0 | 63.0 | 25.0 | False | None | None | False | None | False | 1575.0 | 0 |
2827140 | 91445 | None | code62 | Heat Shrinkable indoor type cable termination kit for XLPE cable /3*95Sq.mm | Set | 4118.4 | 4118.4 | 9.0 | False | None | None | False | None | False | 37065.6 | 0 |
2827141 | 91445 | None | code63 | 11KV, 3Crore, XLPE HTUG Cable (Round Amoured)-95 Sqmm | Km | 978632.6 | 978632.6 | 0.25 | False | None | None | False | None | False | 244658.15 | 0 |
2827142 | 91445 | None | code64 | 3 way RMU 20D+2VL(One Incomer+Two Breakers +One outgoing) conventional RMU's (VCB Type) | Unit | 604505.0 | 604505.0 | 1.0 | False | None | None | False | None | False | 604505.0 | 0 |
2827143 | 91445 | None | code65 | 4 way RMU 20D+2VL(One Incomer+Two Breakers +One outgoing) conventional RMU's (VCB Type) | Unit | 853419.6 | 853419.6 | 1.0 | False | None | None | False | None | False | 853419.6 | 0 |
2827144 | 91445 | None | code66 | Heat Shrinkable straight through jointing kits for XLPE cable with copper lugs & AI ferrules/ 3*95 Sq.mm | Set | 8042.1 | 8042.1 | 4.0 | False | None | None | False | None | False | 32168.4 | 0 |
2827145 | 91445 | None | code67 | Caution/Danger Board | No | 165.0 | 165.0 | 4.0 | False | None | None | False | None | False | 660.0 | 0 |
2827146 | 91445 | None | code68 | 11KV AUTO Reclosures and sectionalizers remote communication facility GSM modem with connecting cable for remote communicating capabilities | Set | 15856.5 | 15856.5 | 2.0 | False | None | None | False | None | False | 31713.0 | 0 |
2827147 | 91445 | None | code69 | L.T.Current Transformers./C.T Ration-50/5A, Class-0.5 accuracy.3.75 VA, ring type | No | 980.1 | 980.1 | 8.0 | False | None | None | False | None | False | 7840.8 | 0 |
2827148 | 91445 | None | code70 | Measuring Equipments-LT Three-Phase , 4 wire CT operated DLMS Complaint ETV meter-5A, Class0.5s occuracy. | No | 3735.6 | 3735.6 | 2.0 | False | None | None | False | None | False | 7471.2 | 0 |
2827149 | 91445 | None | code71 | River sand | Cum | 1940.4 | 1940.4 | 10.0 | False | None | None | False | None | False | 19404.0 | 0 |
2827150 | 91445 | None | code72 | Armoured L.T UG CABLE 1.1KV CLASS 95 SQ.MM 3.5 CORE | Km | 410536.5 | 410536.5 | 0.055 | False | None | None | False | None | False | 22579.5075 | 0 |
2827151 | 91445 | None | code73 | L.T three phase four wire 5-30A Thread through type composite meter housing box of ETV Mete with AMR comply and LTCT WITH BUILT IN GSM / GPRS MODEM up to 100 kVA. | No | 19772.5 | 19772.5 | 2.0 | False | None | None | False | None | False | 39545.0 | 0 |
2827152 | 91445 | None | code74 | Distribution transformer-3 Phase 11KV/433V-stacked Core with oil as per IS-1180 (Part-1):2014 Cable CABLE ENTRY TYPE 63 kVA Aluminium WDG Star-2 (5 Star) | No | 204787.0 | 204787.0 | 1.0 | False | None | None | False | None | False | 204787.0 | 0 |
2827153 | 91445 | None | code75 | Distribution transformer-3 Phase 11KV/433V-stacked Core with oil as per IS-1180 (Part-1):2014 Cable CABLE ENTRY TYPE 250 kVA Aluminium WDG Star-2 (5 Star) | No | 596965.6 | 596965.6 | 1.0 | False | None | None | False | None | False | 596965.6 | 0 |
2827154 | 91445 | None | code76 | supply of GI Wire 10SWG (3.251 mm dia) std wt: 79 kg/KM | MT | 87088.1 | 87088.1 | 0.04 | False | None | None | False | None | False | 3483.524 | 0 |
2827155 | 91445 | None | code77 | Grounding Materials for RMU's & Transformers /Quality Salt for grounding purpose packed in 50 kg gunny bags | Bag | 341.0 | 341.0 | 12.0 | False | None | None | False | None | False | 4092.0 | 0 |
2827156 | 91445 | None | code78 | M S BOLTS AND NUTS | MT | 107619.6 | 107619.6 | 0.04 | False | None | None | False | None | False | 4304.784 | 0 |
2827157 | 91445 | None | code79 | Grounding Materials for RMU's & Transformers /Good Packed in non rolurnable gunny bags of 30 kg each | No | 743.6 | 743.6 | 12.0 | False | None | None | False | None | False | 8923.2 | 0 |
2827158 | 91445 | None | code80 | Grounding Materials for RMU's & Transformers/ G.I.Grounding pipe, B-class, 40mm dia, 2.5 mtrs long, 2.933 thick with bolts nuts, GI Strips and washers complete | No | 817.3 | 817.3 | 12.0 | False | None | None | False | None | False | 9807.6 | 0 |
2827159 | 91445 | None | code81 | Labour for materials:Boring & Drawing of UG cable including preparation at site by trenchless technology by adopting horixontal boring og 5" bore size in normal soil without HDPE pipe. | Rmtr | 1043.9 | 1043.9 | 0.16 | False | None | None | False | None | False | 167.024 | 0 |
2827160 | 91445 | None | code82 | Making and fixing of Heat shrinable straight through joint 3x95 to 3x150 sq.mm H T U G cable only | No | 2923.8 | 2923.8 | 9.0 | False | None | None | False | None | False | 26314.2 | 0 |
2827161 | 91445 | None | code83 | Heat shrinable straight through joint 3x95 to 3x150 sq.mm H T U G cable | No | 3132.8 | 3132.8 | 4.0 | False | None | None | False | None | False | 12531.2 | 0 |
2827162 | 91445 | None | code84 | Lettering the RMU with Enamel paint and also wiring single line diagram of each Panel | No | 1057.1 | 1057.1 | 6.0 | False | None | None | False | None | False | 6342.6 | 0 |
2827163 | 91445 | None | code85 | UG Cablework: Earth work excavation for cable trench of 0.5 to 0.75 mtr width and depth upto 1mtr including trial pits depositing on bank up to a lead of 50 mtrs in ordinary soil | Cum | 286.0 | 286.0 | 50.0 | False | None | None | False | None | False | 14300.0 | 0 |
2827164 | 91445 | None | code86 | Digging of pit for proiding GI pipe type earthing in ordinary soil | No | 834.9 | 834.9 | 12.0 | False | None | None | False | None | False | 10018.8 | 0 |
2827165 | 91445 | None | code87 | Fixing Danger Board | Unit | 88.0 | 88.0 | 4.0 | False | None | None | False | None | False | 352.0 | 0 |
2827166 | 91445 | None | code88 | Erection of RMU | No | 3393.5 | 3393.5 | 2.0 | False | None | None | False | None | False | 6787.0 | 0 |
2827167 | 91445 | None | code89 | Erection 0f 25- 63 kVA transformer on transformer structure | No | 1312.3 | 1312.3 | 1.0 | False | None | None | False | None | False | 1312.3 | 0 |
2827168 | 91445 | None | code90 | Erection 0f 200- 250 kVA transformer on transformer structure | No | 2505.8 | 2505.8 | 1.0 | False | None | None | False | None | False | 2505.8 | 0 |
2827169 | 91445 | None | code91 | Providing GI Pipe Earthing For Lightning arresters.Transformer neutal/ Transformer Metal parts (Excluding digging of pits | Set | 209.0 | 209.0 | 12.0 | False | None | None | False | None | False | 2508.0 | 0 |
2827170 | 91445 | None | code92 | Construction of platform with size atone, cement concrete for erection of 500 KVA transformer Heavy equipment. Construction of platform (1.5*1.5*1.2) mtr in size stone. For erection of transfmer Heavy equipment including all materials, labour. Excavation of (1.5*1.5*1) mtr pit for foundation proving and laying cement concrete 1:4:8for foundation laid in 1cm thick layers, well compacted curing etc. | No | 33397.1 | 33397.1 | 4.0 | False | None | None | False | None | False | 133588.4 | 0 |