2829451 | 91562 | None | code01 | RCC Drain and Deckslab Earth work excavation by manual means for drains, canals, waste weir, draft,approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications,including setting out, shoring, strutting, barricading, caution lights, removalof stumps and other deleterious matter, excavated surface leveled and sides
neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.In all kinds of soils Depth upto 1.5 m.complete as per the specification and engineer in charge of work | Cum | 249.26 | 249.26 | 249.41 | False | None | None | False | None | False | 62167.9366 | 0 |
2829452 | 91562 | None | code02 | Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work.complete as per the specification and engineer in charge of work | Cum | 87.55 | 87.55 | 41.8 | False | None | None | False | None | False | 3659.59 | 0 |
2829453 | 91562 | None | code03 | Providing and laying in position Cement Concrete for levelling course forall works in foundation. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed, laid inlayers not exceeding 150 mm thickness, well compacted using plate vibrators,including all lead & lifts, cost of all materials of quality, labour, Usage charges ofmachinery, curing, and all the other appurtenances required to complete thework as per technical specificationsMix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates.complete as per the specification and engineer in charge of work | Cum | 6168.67 | 6168.67 | 16.67 | False | None | None | False | None | False | 102831.7289 | 0 |
2829454 | 91562 | None | code04 | Providing and laying in position Cement Concrete for all Sub structures ofbuilding, Irrigation works, Sub structure works of bridges, Drain works &other parallel works from 0.50m to 3.50 m height. The granite/trap/basaltcrushed graded coarse aggregates and fine aggregates as per relevant ISCodes machine mixed with super plasticisers, laid in layers, well compactedusing needle vibrators, providing weep holes wherever necessary, includingall lead & lifts, cost of all materials of quality, confirming to the requirementsof relevant IS codes, labour, Usage charges of machinery, curing and all otherappurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.complete as per the specification and engineer in charge of work | Cum | 6838.32 | 6838.32 | 158.4555 | False | None | None | False | None | False | 1083569.41476 | 0 |
2829455 | 91562 | None | code05 | STEEL FABRICATION Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / softannealed steel wire and other ancilary operations complete as per drawing andtechnicalspecification All other type of structures.complete as per the specification and engineer in charge of work | Tonne | 81381.33 | 81381.33 | 13.81 | False | None | None | False | None | False | 1123876.1673 | 0 |
2829456 | 91562 | None | code06 | Providing and laying 100mm thick pre-cast cover slabs over drains &Rain pit of width not exceeding 800 mm using M20 concrete reinforcedwith Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete.complete as per the specification and engineer in charge of work | Mtr | 955.84 | 955.84 | 275.0 | False | None | None | False | None | False | 262856.0 | 0 |
2829457 | 91562 | None | code07 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.complete as per the specification and engineer in charge of work | Cum | 273.98 | 273.98 | 4.05 | False | None | None | False | None | False | 1109.619 | 0 |
2829458 | 91562 | None | code08 | CC RoadConstruction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.complete as per the specification and engineer in charge of work | Cum | 414.06 | 414.06 | 311.418 | False | None | None | False | None | False | 128945.73708 | 0 |
2829459 | 91562 | None | code09 | Compacting Original Ground Loosening, leveling and Compacting original ground supportingembankment to facilitate placement of first layer of embankment,scarified to a depth of 150 mm, mixed with water at OMC and thencompacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction.complete as per the specification and engineer in charge of work | Cum | 108.15 | 108.15 | 192.5235 | False | None | None | False | None | False | 20821.416525 | 0 |
2829460 | 91562 | None | code10 | Providing, laying, spreading and compacting graded stoneaggregate to wet mix macadam specification including premixingthe Material with water at OMC in mechanical mix plant carriageof mixed Material by tipper to site, laying in uniform layers withpaver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.complete as per the specification and engineer in charge of work | Cum | 2635.77 | 2635.77 | 137.62 | False | None | None | False | None | False | 362734.6674 | 0 |
2829461 | 91562 | None | code11 | Providing and constructing un-reinforced plain cementconcrete pavement, thickness as per design, over a preparedsub base, with 43 grade cement or any other type as perClause 1501.2.2 M20 (Grade), coarse and fine aggregatesconforming to IS:383:2016, maximum size of coarseaggregate not exceeding 25 mm, mixed in a concrete mixerof not less than 0.2 cum capacity and appropriate weighbatcher using approved mix design, laid in approved fixedside formwork (steel channel, laying and fixing of 125 micronthick polythene film, wedges, steel plates including levellingthe formwork as per drawing), spreading the concrete withshovels, rakes, compacted using needle,screed and plate vibrators and finished in continuous operation includingconstruction joints, , primer, sealant , curing of concreteslabs for 14days, and water finishing to lines and grade asper drawing and technical specification clause 1501 with alllead, lifts, loading & unloading charges, cost and conveyanceof all materials, labour, equipments etc., complete. as per the
directions of the Engineer-in-charge of the work. | Cum | 6565.22 | 6565.22 | 137.62 | False | None | None | False | None | False | 903505.5764 | 0 |
2829462 | 91562 | None | code12 | Retaining Wall Earth work in surface excavation for stripping, seating of bund, Road way bymanual means for lowering & levelling the ground for all works other thanfoundation & depth in Ordinary rock and soft rock upto 300mm depth as perdrawing and technical specifications, including setting out, barricading, cautionlights, including dressing of excavated surfaces, disposing off or levelling theexcavated stuff or sorting & stacking the selected stuff for reuse in a radiusof 50 m and lift upto 1.5 m including cost of labour, tools, usage& otherappurtenances required to complete the work. | Cum | 592.25 | 592.25 | 30.98 | False | None | None | False | None | False | 18347.905 | 0 |
2829463 | 91562 | None | code13 | Providing and fixing hand rail of approved size by welding etc. to steel
ladder railing, balcony railing, staircase railing and similar works,
including applying priming coat of approved steel primer. G.I. pipes
including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Mtr | 188.49 | 188.49 | 2310.0 | False | None | None | False | None | False | 435411.9 | 0 |
2829464 | 91562 | None | code14 | Water Supply Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVCplain & brass threaded fittings This includes jointing of pipes & fittingswith one step CPVC solvent cement, trenching, refilling & testing of joints.complete as per direction of Engineer in Charge. External work 40mm nominal OD pipes | Mtr | 491.31 | 491.31 | 532.0 | False | None | None | False | None | False | 261376.92 | 0 |
2829465 | 91562 | None | code15 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVCplain & brass threaded fittings This includes jointing of pipes & fittingswith one step CPVC solvent cement, trenching, refilling & testing of joints.complete as per direction of Engineer in Charge. External work 80mm nominal OD pipes | Mtr | 1846.79 | 1846.79 | 388.0 | False | None | None | False | None | False | 716554.52 | 0 |
2829466 | 91562 | None | code16 | Providing and placing on terrace (at all floor levels) polyethylenwater storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank. | Nos | 9.27 | 9.27 | 38000.0 | False | None | None | False | None | False | 352260.0 | 0 |
2829467 | 91562 | None | code17 | Providing of Gunmetal Ball Valve of Non rising stem, screwed in bonnet,inside screw, integral seats, screwed female ends to IS:554/ BS 21/ ISO7, Unbreakable sheet metal Handwheel, confoming to IS:778 Class-1including provision of re-packing under pressure with appurtenances,complete : 150 mm nominal bore etc. complete | Each | 217.33 | 217.33 | 38.0 | False | None | None | False | None | False | 8258.54 | 0 |
2829468 | 91562 | None | code18 | Providing, fabricating and fixing at site various diameter MS MJ endswith dummy plates (END CAPS) to suit CI / DI spigots end as per thesketch. The cost is inclusive of all materials, i.e, rubber 'O' rings, flanges,bolts and nuts, dummy plates, consumables, hire charges, tools and welding equipments, lead and lifts, etc. complete as per the instructions Engineer in charge.For CI / DI pipes of 100 mm dia.complete as per the specification and engineer in charge of work | Each | 1192.74 | 1192.74 | 38.0 | False | None | None | False | None | False | 45324.12 | 0 |
2829469 | 91562 | None | code19 | Heavy duty copper terminals long barrel 95 Sq.mm copper terminals | Nos | 133.0 | 133.0 | 20.0 | False | None | None | False | None | False | 2660.0 | 0 |
2829470 | 91562 | None | code20 | Heat Shrinkable Type Transition Jointing Kit for XLPE Cable 3x95 Sqmm complete as per the specification and engineer in charge of work | Set | 10246.0 | 10246.0 | 2.0 | False | None | None | False | None | False | 20492.0 | 0 |
2829471 | 91562 | None | code21 | Heat Shrinkable Indoor Type Cable Termination Kit for XLPE Cable 3x95 Sqmm complete as per the specification and engineer in charge of work | Set | 3744.0 | 3744.0 | 6.0 | False | None | None | False | None | False | 22464.0 | 0 |
2829472 | 91562 | None | code22 | L.T.Current Transformers./C.T Ration-150/5A, Class-0.5 accuracy.3.75 VA, ring type complete as per the specification and engineer in charge of work | Nos | 494.0 | 494.0 | 8.0 | False | None | None | False | None | False | 3952.0 | 0 |
2829473 | 91562 | None | code23 | L.T Metering Box for housing the ETV Meters without CT'S Busbar wiring etc.complete as per the specification and engineer in charge of work | Nos | 3644.0 | 3644.0 | 2.0 | False | None | None | False | None | False | 7288.0 | 0 |
2829474 | 91562 | None | code24 | Caution/Danger Board (Item no 68.17,593,PWD SR 2023-24 Page No:32) | Nos | 150.0 | 150.0 | 4.0 | False | None | None | False | None | False | 600.0 | 0 |
2829475 | 91562 | None | code25 | 4 way RMU 20D+2VL(One Incomer+Two Breakers +One outgoing) conventional RMU's (VCB Type) with copper Bus ba 350MVA, 630 Amps complete as per the specification and engineer in charge of work | Set | 1876886.0 | 1876886.0 | 1.0 | False | None | None | False | None | False | 1876886.0 | 0 |
2829476 | 91562 | None | code26 | Measuring Wquioments-LT Three-Phase , 4 wire CT operated DLMS Complaint ETV meter-5A, Class0.5s occuracy. complete as per the specification and engineer in charge of work | Nos | 3396.0 | 3396.0 | 2.0 | False | None | None | False | None | False | 6792.0 | 0 |
2829477 | 91562 | None | code27 | GPRS Modems with Accessories complete as per the specification and engineer in charge of work | Nos | 4598.0 | 4598.0 | 2.0 | False | None | None | False | None | False | 9196.0 | 0 |
2829478 | 91562 | None | code28 | For Distribution transformer centres MS Box for housing the ETV Mater 3 Phase 4 wire 5A, with associated LT CTs Class 0.5 accurancy, ring type with wiring clamps B& N and all other accessories rewuired (Excluding ETV METER)/ SMC metering box as above.With CT Ratio 50/5 for 15/25 kVA DTC complete as per the specification and engineer in charge of work | Set | 6836.0 | 6836.0 | 2.0 | False | None | None | False | None | False | 13672.0 | 0 |
2829479 | 91562 | None | code29 | LT Distribution Box for 100/250 kVA DTC with MCCB's (SMC) complete as per the specification and engineer in charge of work | Nos | 24428.0 | 24428.0 | 2.0 | False | None | None | False | None | False | 48856.0 | 0 |
2829480 | 91562 | None | code30 | Grounding Materials for RMUs & Transformers /Good Packed in non rolurnable gunny bags of 30 kg each.complete as per the specification and engineer in charge of work | No | 660.0 | 660.0 | 9.0 | False | None | None | False | None | False | 5940.0 | 0 |
2829481 | 91562 | None | code31 | Grounding Materials for RMUs & Transformers /Quality Salt for grounding purpose packed in 50 kg gunny bags.complete as per the specification and engineer in charge of work | Bag | 303.0 | 303.0 | 9.0 | False | None | None | False | None | False | 2727.0 | 0 |
2829482 | 91562 | None | code32 | Grounding Materials for RMUs & Transformers/ G.I.Grounding pipe, B-class, 40mm dia, 2.5 mtrs long, 2.933 thick with bolts nuts, GI Strips and washers complete | No | 770.0 | 770.0 | 9.0 | False | None | None | False | None | False | 6930.0 | 0 |
2829483 | 91562 | None | code33 | 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975 95 Sqmm, (54 GI Wires - 2.5 mm Dia) complete as per the specification and engineer in charge of work. | Km | 889666.0 | 889666.0 | 0.07 | False | None | None | False | None | False | 62276.62 | 0 |
2829484 | 91562 | None | code34 | Distribution Transformer - 3 Phase, 11kV/433V - Amorphous Core with Oil as per IS-1180 (Part-1): 2014 100 kVA, Aluminium Wdg, Star 2 (5 Star) complete as per the specification and engineer in charge of work | Nos | 220185.0 | 220185.0 | 2.0 | False | None | None | False | None | False | 440370.0 | 0 |
2829485 | 91562 | None | code35 | Digging of pit for providing GI pipe type earthing in ordinary soil complete as per the specification and engineer in charge of work | Nos | 629.0 | 629.0 | 9.0 | False | None | None | False | None | False | 5661.0 | 0 |
2829486 | 91562 | None | code36 | Fixing foundation frame of channels and angle iron welding fixing in concrete aligning the RMU on foundation bed, assembly of units, connecting Bus Bars from panel to panel initial filling of oil etc., complete.complete as per the specification and engineer in charge of work | Nos | 23354.0 | 23354.0 | 1.0 | False | None | None | False | None | False | 23354.0 | 0 |
2829487 | 91562 | None | code37 | Laying of UG Cables by Trenchless Technology (HDD) by adopting Horizontal Boring & Drawing of cable including preparation at site Normal soil 5/6'' Bore complete as per the specification and engineer in charge of work | Mtr | 949.0 | 949.0 | 62.0 | False | None | None | False | None | False | 58838.0 | 0 |
2829488 | 91562 | None | code38 | Labour for GPRS modems with Accessoriescomplete as per the specification and engineer in charge of work | No | 1346.0 | 1346.0 | 2.0 | False | None | None | False | None | False | 2692.0 | 0 |
2829489 | 91562 | None | code39 | Construction of platform with size stone, cement concrete for erection of 500 KVA transformer Heavy equipment. Construction of platform (1.5*1.5*1.2) mtr in size stone. For erection of transfmer Heavy equipment including all materials, labour. Excavation of (1.5*1.5*1) mtr pit for foundation proving and laying cement concrete 1:4:8for foundation laid in 1cm thick layers, well compacted curing etc. | No | 30361.0 | 30361.0 | 4.0 | False | None | None | False | None | False | 121444.0 | 0 |
2829490 | 91562 | None | code40 | External Electrification Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.complete as per the specification and engineer in charge of work | Each | 241.0 | 241.0 | 110.0 | False | None | None | False | None | False | 26510.0 | 0 |
2829491 | 91562 | None | code41 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 complete as per the specification and engineer in charge of work | Each | 739.0 | 739.0 | 110.0 | False | None | None | False | None | False | 81290.0 | 0 |
2829492 | 91562 | None | code42 | Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparentPolycarbonate Lid, shock proof, IP65 (Weather Proof),rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout withsuitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility.complete as per the specification and engineer in charge of work | Each | 6163.0 | 6163.0 | 110.0 | False | None | None | False | None | False | 677930.0 | 0 |
2829493 | 91562 | None | code43 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. ( Icu = Ics)
complete as per the specification and engineer in charge of work | Each | 10341.0 | 10341.0 | 4.0 | False | None | None | False | None | False | 41364.0 | 0 |
2829494 | 91562 | None | code44 | Wiring for lighting/power circuit using one of PVC insulated 1100V grade, stranded Aluminium wire single core in open or concealed system of wiring.complete as per the specification and engineer in charge of work | Mtr | 19.0 | 19.0 | 180.0 | False | None | None | False | None | False | 3420.0 | 0 |
2829495 | 91562 | None | code45 | Earth work excavation for pipelines/cables by Manual means upto 600 mmtrench width, as per drawing and technical specifications, including settingout, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.complete as per the specification and engineer in charge of work. | Cum | 484.0 | 484.0 | 54.0 | False | None | None | False | None | False | 26136.0 | 0 |
2829496 | 91562 | None | code46 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 .complete as per the specification and engineer in charge of work | Cum | 225.0 | 225.0 | 200.0 | False | None | None | False | None | False | 45000.0 | 0 |
2829497 | 91562 | None | code47 | Filling available excavated earth (excluding rock) in trenches, plinth,
sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m complete as per the specification and engineer in charge of work | Nos | 266.0 | 266.0 | 54.0 | False | None | None | False | None | False | 14364.0 | 0 |
2829498 | 91562 | None | code48 | KSRB 4-1.3 : Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) complete as per the specification and engineer in charge of work | Cum | 5364.0 | 5364.0 | 33.1875 | False | None | None | False | None | False | 178017.75 | 0 |
2829499 | 91562 | None | code49 | Providing and laying in position Cement Concrete for all Sub structures ofbuilding, Irrigation works, Sub structure works of bridges, Drain works &other parallel works from 0.50m to 3.50 m height. The granite/trap/basaltcrushed graded coarse aggregates and fine aggregates as per relevant ISCodes machine mixed with super plasticisers, laid in layers, well compactedusing needle vibrators, providing weep holes wherever necessary, includingall lead & lifts, cost of all materials of quality, confirming to the requirementsof relevant IS codes, labour, Usage charges of machinery, curing and all otherappurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatescomplete as per the specification and engineer in charge of work | Cum | 6323.0 | 6323.0 | 18.0 | False | None | None | False | None | False | 113814.0 | 0 |
2829500 | 91562 | None | code50 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding) complete as per the specification and engineer in charge of work | Kgs | 168.0 | 168.0 | 1512.0 | False | None | None | False | None | False | 254016.0 | 0 |
2829501 | 91562 | None | code51 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts .complete as per the specification and engineer in charge of work | Nos | 4150.0 | 4150.0 | 12.0 | False | None | None | False | None | False | 49800.0 | 0 |
2829502 | 91562 | None | code52 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. complete as per the specification and engineer in charge of work | m | 128.0 | 128.0 | 660.0 | False | None | None | False | None | False | 84480.0 | 0 |
2829503 | 91562 | None | code53 | Providing and installing at site of work P.V.C. pipes including cost of pipesand specials and labour, including lowering into trenches, laying trueto line, level and perfect linking at joints leak proof including jointingof approved type with all labour charges and all lift charges, handlingcharges including encasing the pipe around to a depth not less than15 cms with gravel or selected earth available from the excavation etc.complete as per the specification and engineer in charge of work | m | 332.0 | 332.0 | 110.0 | False | None | None | False | None | False | 36520.0 | 0 |
2829504 | 91562 | None | code54 | Wiring for lighting/power circuit using one of FRLS PVC insulted 1.1 kV grade multi strand copper with low conductor resistance 2.5 Sqmm single core wire in open are concealed system of wiring with specified IS-694-1990 and conform into GTP of group A.complete as per the specification and engineer in charge of work | m | 35.0 | 35.0 | 320.0 | False | None | None | False | None | False | 11200.0 | 0 |
2829505 | 91562 | None | code55 | Wiring for lighting/power circuit using one of FRLS PVC insulted 1.1 kV grade multi strand copper with low conductor resistance 4 Sqmm single core wire in open are concealed system of wiring with specified IS-694-1990 and conform into GTP of group A | m | 49.0 | 49.0 | 960.0 | False | None | None | False | None | False | 47040.0 | 0 |
2829506 | 91562 | None | code56 | Pole Electrification | Nos | 1667135.0 | 1667135.0 | 1.0 | False | None | None | False | None | False | 1667135.0 | 0 |
2829507 | 91562 | None | code57 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3and minimum compressive strength of 4.00 N/mm2 conforming to IS2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications complete as per the specification and engineer in charge of work | Sqm | 1267.93 | 1267.93 | 240.0 | False | None | None | False | None | False | 304303.2 | 0 |
2829508 | 91562 | None | code58 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-chargecomplete as per the specification and engineer in charge of work | Sqm | 262.65 | 262.65 | 300.0 | False | None | None | False | None | False | 78795.0 | 0 |
2829509 | 91562 | None | code59 | Providing lime rendering for plastering to wall and ceiling, including cost of materials, labour, curing complete as per specifications., including cost of materials, labour, curing as per specification with all lead and lift, loading, unloading and labour charges etc., complete and as per the directions of the Engineer-in-Charge of the work. | Sqm | 32.78 | 32.78 | 300.0 | False | None | None | False | None | False | 9834.0 | 0 |
2829510 | 91562 | None | code60 | Finishing walls with 100% Premium acrylic emulsion paint having VOCless than 50 g/L and UV resistance as per IS 15489:2004, Alkali& fungal resistance, dirt resistance exterior paint of required shade(Company Depot Tinted) with silicon additives, New work (Two coatsapplied @ 1.43 L/ 10 m². Over and including priming coat of exteriorprimer applied @ 0.90 L/10 m² with paint of approved quality to give aneven shade, after thoroughly brooming the surface to remove all dirt, dust,mortar drops and foreign matter including preparing the surface even andsand paper smooth, cost of materials, labour complete as per specificationsand as per directions of Engineer-in-charge. (Volume-II Page No:46 Item no;8.32 2023-24 SR) | Sqm | 160.68 | 160.68 | 220.0 | False | None | None | False | None | False | 35349.6 | 0 |
2829511 | 91562 | None | code61 | Providing and laying plat form using prepolished, water cut / gang saw 40mm thick telephonic Black Granite. laid on existing vertical -supports and fixing in CM 1:3 proportion. Including cutting to required shape, pattern with paper joints, including full rounding for nosing, finished with cement mortar, pointed with colour pigments to match the colour of slab making through jointing with sealant, making holes 25mm x 12mm grooves in joints including curing. -- Kitchen Platform | Sqm | 3611.18 | 3611.18 | 378.0 | False | None | None | False | None | False | 1365026.04 | 0 |
2829512 | 91562 | None | code62 | Stainless steel kitchen sink - with drain board 510 x 1040mm bowl depth
225 mm. Item no: 907 page No:A-39 Volume-II 2023-24 SR | Each | 3605.0 | 3605.0 | 400.0 | False | None | None | False | None | False | 1442000.0 | 0 |
2829513 | 91562 | None | code63 | Street Lamps FabricatingsupplyingandmountingMSboxmadeout....SWGsuitableforfloor/wallmounting,fullyweatherproofwithprovisionforbetterheatdissipation,providedwithhingedfrontcover,equippedwithtamperprooflockingarrangements,withsuitablesizeclampswithnecessarycableentrypipewithglandandboxshouldbefinishedwith7tankstreatmentwithpowdercoatedpaintand finally finished with approved colour etc., complete.(PWD Electrical SR 2023-24 Page No 20, Item No 5.42.1) 14SWG | Sq CM | 0.5 | 0.5 | 25000.0 | False | None | None | False | None | False | 12500.0 | 0 |
2829514 | 91562 | None | code64 | Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 100Amps 4x30x6mm Alluminium Strips.complete as per the specification and engineer in charge of work | Mtr | 2465.0 | 2465.0 | 1.0 | False | None | None | False | None | False | 2465.0 | 0 |
2829515 | 91562 | None | code65 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 50x50x6mm.complete as per the specification and engineer in charge of work | Mtr | 395.0 | 395.0 | 2.0 | False | None | None | False | None | False | 790.0 | 0 |
2829516 | 91562 | None | code66 | Supplying,fixing and wiring Residual current circuit breaker(RCCB)240/450V upto 300mA sensitivity on existing wood/ panel board. complete as per the specification and engineer in charge of work 32-40A 2 pole | Each | 4559.0 | 4559.0 | 1.0 | False | None | None | False | None | False | 4559.0 | 0 |
2829517 | 91562 | None | code67 | Supplying & fixingof Porcelain fuse channel with cutout on existing wooden/panel using necessary nuts, bolts and washerscomplete as per the specification and engineer in charge of work 32Amps | Each | 241.0 | 241.0 | 3.0 | False | None | None | False | None | False | 723.0 | 0 |
2829518 | 91562 | None | code68 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. complete as per the specification and engineer in charge of work 63Amps | Each | 401.0 | 401.0 | 3.0 | False | None | None | False | None | False | 1203.0 | 0 |
2829519 | 91562 | None | code69 | Fabricating,supplyinganderectionof...mslonghotdipGalvanizedOctagonalhotdipPolewithBSEN10025gradeS355JOsteelplateforshaft,IS2062forbaseplatewithdooropeningarrangements,includingsuitableboards,BakelitesheetandMCBsasperISspecificationssuitabletowithstandthewindspeedof47m/sfor.......mPoleinsinglesectionandsinglejointweldedasperIS9595/IS10178AWShavingdimensionsbottom.....mm,top....mmwith3mmthick,suitablebaseplateand4Nosof.....longJboltsalongwithtemplateandthePoleshallbehotdipgalvanizedinsingledippingwithnotlessthan65micronasperASTM-A123and153etc.,(excluding foundation) as per drawing appended. 4 m - Top 70 mm and Bottom 130 mm diacomplete as per the specification and engineer in charge of work | Each | 8200.0 | 8200.0 | 20.0 | False | None | None | False | None | False | 164000.0 | 0 |
2829520 | 91562 | None | code70 | Refilling available earth around trenches/pipelines, cables in layers notexceeding 20 cms in depth, compacting each deposited layer by ramming afterwatering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labourcomplete as per specificationscomplete as per the specification and engineer in charge of work | Mtr | 160.0 | 160.0 | 270.0 | False | None | None | False | None | False | 43200.0 | 0 |
2829521 | 91562 | None | code71 | Earth work excavation for pipeline trenches in all kinds of soils by mechanicalmeans as per drawing and technical specifications, including setting out,construction of shoring, strutting, barricading, caution lights, bracing, usingsight rails & bonding rods at every 100 mm wherever necessary as directed,removal of stumps and other deleterious matter, dressing of sides and levellingthe bottom of trench to the extent required , utilising the available excavatedearth locally for the work etc., and all other appurtenances complete in thefollowing strata. Depth upto 1.50m 0.50x0.5x0.40x20=2.00cum.complete as per the specification and engineer in charge of work | Cum | 262.0 | 262.0 | 40.0 | False | None | None | False | None | False | 10480.0 | 0 |
2829522 | 91562 | None | code72 | Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed In Ordinary Soil complete as per the specification and engineer in charge of work. | Cum | 260.0 | 260.0 | 101.25 | False | None | None | False | None | False | 26325.0 | 0 |
2829523 | 91562 | None | code73 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates 0.350 Cum/Pole.complete as per the specification and engineer in charge of work | Cum | 6323.0 | 6323.0 | 7.0 | False | None | None | False | None | False | 44261.0 | 0 |
2829524 | 91562 | None | code74 | Supplying, Fitting and Placing TMT Fe 500 & above Reinforcement in Foundation / Substructure /Superstructure complete as per Drawing and Technical Specifications. 15.53 Kg/Pole.complete as per the specification and engineer in charge of work | Tonne | 79011.0 | 79011.0 | 0.31 | False | None | None | False | None | False | 24493.41 | 0 |
2829525 | 91562 | None | code75 | Supplying of 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975, Material Code: 287206 complete as per the specification and engineer in charge of work. | Km | 141842.0 | 141842.0 | 0.27 | False | None | None | False | None | False | 38297.34 | 0 |
2829526 | 91562 | None | code76 | SupplyinganddrawingFlexibleMulticoreCablemanufacturedwithelectrolyticgradeflexiblecopperwithlowconductorconfirmingtoIS8130-1984and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990.complete as per the specification and engineer in charge of work | Mtr | 94.0 | 94.0 | 90.0 | False | None | None | False | None | False | 8460.0 | 0 |
2829527 | 91562 | None | code77 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff (PWD Electrical SR BESCOM Part-IV, 11kv Labours 2023-24 Page No 52 , Item No 21.05,) | Km | 20886.0 | 20886.0 | 0.27 | False | None | None | False | None | False | 5639.22 | 0 |
2829528 | 91562 | None | code78 | Supplying and installation of Class SN8 Double Wall Corrugated HDPE pipe outer wall corrugated and inner wall smooth piping system in accordance with IS 16098 part 2 and conveying to work site and lowering into trenches, laying true to line and level and perfect linking at joints with the help of two “O” rings and a coupler of suitable size, including loading and unloading at both destination and cutting of pipes where ever necessary including jointing with all labour, all lead and lift including encasing the pipe around to a depth of not less than 15 cm with screened soft soil available from the excavated soil. The testing commissioning including necessary hydraulic test to the required pressure as per ISS shall be done the contractor shall have to make his own arrangement for procuring water for testing.complete as per the specification and engineer in charge of work | Nos | 222.0 | 222.0 | 270.0 | False | None | None | False | None | False | 59940.0 | 0 |
2829529 | 91562 | None | code79 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70 percent, maximum light intensity should be between 60 degrees to 70 degrees. CCT GREATER THAN 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection Min 5KV along with Over voltage/Overload, short circuit/ miss wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency greater than 1301m/w, nominal CRI greater than 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned LED Streetlight 90 W complete as per the specification and engineer in charge of work | Nos | 8860.0 | 8860.0 | 20.0 | False | None | None | False | None | False | 177200.0 | 0 |
2829530 | 91562 | None | code80 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. (PWD Electrical SR 2023-24 Page No 19, Item No 5.38) | Nos | 515.0 | 515.0 | 4.0 | False | None | None | False | None | False | 2060.0 | 0 |
2829531 | 91562 | None | code81 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipments on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proprotion of salt and charcoal 150mm alround the pipe to complete depth. The connection from the pipe to the conduit etc, is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and checknuts etc, the pipe shall have 16 through holes of 122 mm diacomplete as per the specification and engineer in charge of work | Nos | 2727.0 | 2727.0 | 1.0 | False | None | None | False | None | False | 2727.0 | 0 |
2829532 | 91562 | None | code82 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. Four Pole,100Amps 25kA. (PWD Electrical SR 2023-24 Page No 17, Item No 5.15.9) | Nos | 8487.0 | 8487.0 | 1.0 | False | None | None | False | None | False | 8487.0 | 0 |
2829533 | 91562 | None | code83 | Geophysical investigation at site for sinking borewells for supplying drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers’s method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30%(Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. complete as per the specification and engineer in charge of work | Nos | 5141.0 | 5141.0 | 1.0 | False | None | None | False | None | False | 5141.0 | 0 |
2829534 | 91562 | None | code84 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) Water supply & UGD Works | Mtr | 290.0 | 290.0 | 50.0 | False | None | None | False | None | False | 14500.0 | 0 |
2829535 | 91562 | None | code85 | b 50.00 100.00 Mtrs | Mtr | 364.0 | 364.0 | 50.0 | False | None | None | False | None | False | 18200.0 | 0 |
2829536 | 91562 | None | code86 | c 100.00 - 150.00 Mtrs | Mtr | 387.0 | 387.0 | 50.0 | False | None | None | False | None | False | 19350.0 | 0 |
2829537 | 91562 | None | code87 | d 150.00 - 200.00 Mtrs | Mtr | 449.0 | 449.0 | 50.0 | False | None | None | False | None | False | 22450.0 | 0 |
2829538 | 91562 | None | code88 | e 200.00 - 250.00 Mtrs | Mtr | 527.0 | 527.0 | 50.0 | False | None | None | False | None | False | 26350.0 | 0 |
2829539 | 91562 | None | code89 | f 250.00 - 300.00 Mtrs | Mtr | 558.0 | 558.0 | 50.0 | False | None | None | False | None | False | 27900.0 | 0 |
2829540 | 91562 | None | code90 | g 300.00 - 350.00 Mtrs | Mtr | 620.0 | 620.0 | 50.0 | False | None | None | False | None | False | 31000.0 | 0 |
2829541 | 91562 | None | code91 | Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. Water supply & UGD Works complete as per the specification and engineer in charge of work | Mtr | 1933.0 | 1933.0 | 40.0 | False | None | None | False | None | False | 77320.0 | 0 |
2829542 | 91562 | None | code92 | Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all
amendments. Water supply & UGD Works .complete as per the specification and engineer in charge of work | No | 150.0 | 150.0 | 1.0 | False | None | None | False | None | False | 150.0 | 0 |
2829543 | 91562 | None | code93 | Providing and laying at site of work MS casing caps as per IS 1239 (partII) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge. Water supply & UGD Works .complete as per the specification and engineer in charge of work | No | 164.0 | 164.0 | 1.0 | False | None | None | False | None | False | 164.0 | 0 |
2829544 | 91562 | None | code94 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, layingn true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges,
handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.Water supply & UGD Works | Mtr | 1677.0 | 1677.0 | 15.0 | False | None | None | False | None | False | 25155.0 | 0 |
2829545 | 91562 | None | code95 | Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 3 HP Water supply & UGD Works 17.50 HP - 135 LPM @ 350 m = 25 STG Outlet Dia - 2.00” complete as per the specification and engineer in charge of work | No | 78963.0 | 78963.0 | 1.0 | False | None | None | False | None | False | 78963.0 | 0 |
2829546 | 91562 | None | code96 | Submersible Cable:- Supply and delivery at site Brand new best make PVC insulated cable of
Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990
with ISI Mark and as per its latest amendments. Water supply & UGD Works | Sqm | 165.0 | 165.0 | 560.0 | False | None | None | False | None | False | 92400.0 | 0 |
2829547 | 91562 | None | code97 | Supply and delivery of galvanized mild steel tubes of 6mtr standard length heavy duty (C Class) as per IS 1239 (Part-I) 1990 with latest amendments with ISI Mark (one end fitted with Heavy Duty collar and other end fitted with protective cover)Water supply & UGD Works | Each | 3050.0 | 3050.0 | 8.0 | False | None | None | False | None | False | 24400.0 | 0 |
2829548 | 91562 | None | code98 | Supply and delivery at site of brand new best make gate valve as per IS
778/1984 with ISI Mark and as per its latest amendments. complete as per the specification and engineer in charge of work | Each | 1250.0 | 1250.0 | 1.0 | False | None | None | False | None | False | 1250.0 | 0 |
2829549 | 91562 | None | code99 | Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments.complete as per the specification and engineer in charge of work | Each | 1275.0 | 1275.0 | 1.0 | False | None | None | False | None | False | 1275.0 | 0 |
2829550 | 91562 | None | code100 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :complete as per the specification and engineer in charge of work | No | 834.0 | 834.0 | 3.0 | False | None | None | False | None | False | 2502.0 | 0 |
2829551 | 91562 | None | code101 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOLDirect Online Starter 2) S-D- Star Delta Starte..Water supply & UGD Works .complete as per the specification and engineer in charge of work | No | 16500.0 | 16500.0 | 1.0 | False | None | None | False | None | False | 16500.0 | 0 |
2829552 | 91562 | None | code102 | Supply and delivery at site delivery of best indigenous brand new MCB (Miniature Circuit Breakers) of required capacity as per IS 88228/1978 and its latest amendments and with ISI Mark of 6/10/16/20/25/40 Amps with scalable box.Water supply & UGD Works.complete as per the specification and engineer in charge of work | Kvar | 1250.0 | 1250.0 | 1.0 | False | None | None | False | None | False | 1250.0 | 0 |
2829553 | 91562 | None | code103 | Supply and delivery at site best indigenous brand new power capacitor as per IS 2834/1986 with latest amendments with KPTCL authorities and erection, electrification and commissioning of the same at the location of respective pump sets.Water supply & UGD Works .complete as per the specification and engineer in charge of work | Nos | 550.0 | 550.0 | 4.0 | False | None | None | False | None | False | 2200.0 | 0 |
2829554 | 91562 | None | code104 | Supply and delivery at site best indigenous brand new power capacitor as per IS 2834/1986 with latest amendments with KPTCL authorities and erection, electrification and commissioning of the same at the location of respective pump sets.Water supply & UGD Works .complete as per the specification and engineer in charge of work | No | 6150.0 | 6150.0 | 1.0 | False | None | None | False | None | False | 6150.0 | 0 |
2829555 | 91562 | None | code105 | Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia.Water supply & UGD Works .complete as per the specification and engineer in charge of work | Per Job | 3750.0 | 3750.0 | 1.0 | False | None | None | False | None | False | 3750.0 | 0 |
2829556 | 91562 | None | code106 | Providing,Supplying and fixing suitable for 1.1 KV class UG cable filled with necessary bitumen/insulating compound complete with terminals, clamps,bolts,nuts and washers etc. with necessary materials and labour tools and equipments as per instructions of engineer incharge of work.Water supply & UGD Works | Mtr | 745.0 | 745.0 | 30.0 | False | None | None | False | None | False | 22350.0 | 0 |
2829557 | 91562 | None | code107 | Digging of trench of 0.6m deep x 0.50mtr dua wide refilling the trench to the required ground level and consolidating etc., complete in Ordinary soil complete as per the specification and engineer in charge of work | Mtr | 212.0 | 212.0 | 15.0 | False | None | None | False | None | False | 3180.0 | 0 |
2829558 | 91562 | None | code108 | Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold granite, grey granite in CM 1:3 proportion cut to required shape, pattern with paper joints, finished with cement mortal using white cement and colour pigments to match the colour of slab making through jointing with sealant, making holes 25mmx12mm grooves in joints including curing etc., complete as per the specification and engineer in charge of work | Nos | 3719.0 | 3719.0 | 20.0 | False | None | None | False | None | False | 74380.0 | 0 |
2829559 | 91562 | None | code109 | Engraving of, KSDB approved letters, Beneficiary Name & Number, PMAY logo, with four sides neat border on the granite slab. Applying Silver/gold colors. | Nos | 571.0 | 571.0 | 400.0 | False | None | None | False | None | False | 228400.0 | 0 |
2829560 | 91562 | None | code110 | Labour charge for fixing finised board on to the wall as per SR 2018-19 Zone-2, pg No.LVI Sl No.7 (Laying 4 stones per day) | Nos | 90.0 | 90.0 | 400.0 | False | None | None | False | None | False | 36000.0 | 0 |
2829561 | 91562 | None | code111 | Earthwork excavation for foundation of buildings, culverts, water supply, sanitary lines and electrical conduits either in pits or in trenches 1.5m and above in width, in ordinary soil not exceeding 1.5 m. in depth including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from edges of excavation with lead upto 50 m. after breaking of clods complete as per specifications. | Cum | 249.26 | 249.26 | 78.0 | False | None | None | False | None | False | 19442.28 | 0 |
2829562 | 91562 | None | code112 | Providing and laying in position Cement Concrete for levelling course forall works in foundation. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed, laid inlayers not exceeding 150 mm thickness, well compacted using plate vibrators,including all lead & lifts, cost of all materials of quality, labour, Usage charges ofmachinery, curing, and all the other appurtenances required to complete thework as per technical specificationsMix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6168.0 | 6168.0 | 3.9 | False | None | None | False | None | False | 24055.2 | 0 |
2829563 | 91562 | None | code113 | Providing and laying in position Cement Concrete for all Sub structures ofbuilding, Irrigation works, Sub structure works of bridges, Drain works &other parallel works from 0.50m to 3.50 m height. The granite/trap/basaltcrushed graded coarse aggregates and fine aggregates as per relevant ISCodes machine mixed with super plasticisers, laid in layers, well compactedusing needle vibrators, providing weep holes wherever necessary, includingall lead & lifts, cost of all materials of quality, confirming to the requirementsof relevant IS codes, labour, Usage charges of machinery, curing and all otherappurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.complete as per the specification and engineer in charge of work | Cum | 6838.32 | 6838.32 | 36.7 | False | None | None | False | None | False | 250966.344 | 0 |
2829564 | 91562 | None | code114 | STEEL FABRICATION Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / softannealed steel wire and other ancilary operations complete as per drawing and technical specification All other type of structures.complete as per the specification and engineer in charge of work | Quintal | 8138.0 | 8138.0 | 33.03 | False | None | None | False | None | False | 268798.14 | 0 |
2829565 | 91562 | None | code115 | Providing and fixing M.S. Inspection door of size 60 cms x 60 cms. Including M.S. frame , size 50 x 50 x 6 mm and shutters of 3 mm thickness with hinges at top and locking arrangements, painting with all lead and lifts etc., complete..complete as per the specification and engineer in charge of work | Each | 2111.0 | 2111.0 | 13.0 | False | None | None | False | None | False | 27443.0 | 0 |
2829566 | 91562 | None | code116 | Providing, supplying to work site,Single Phase Submersible Pump Sets
of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000
specifications,with testing of as per instructions of engineer incharge of work and latest amendments.P080 1 HP/1.5KW,12 STG.complete as per the specification and engineer in charge of work | Nos | 8500.0 | 8500.0 | 13.0 | False | None | None | False | None | False | 110500.0 | 0 |
2829567 | 91562 | None | code117 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete. (internal work exposed on wall) - 40mm nominal OD pipes.complete as per the specification and engineer in charge of work | Mtr | 337.0 | 337.0 | 130.0 | False | None | None | False | None | False | 43810.0 | 0 |