| 2828494 | 91533 | None | 1.4.1 | Earth work excavation by manual means for drains, canals, waste weir, draft,
approach channels, key trenches, foundation of Buildings & bridges and such
simillar works in all kinds of soils, as per drawing and technical specifications,
including setting out, shoring, strutting, barricading, caution lights, removal
of stumps and other deleterious matter, excavated surface leveled and sides
neatly dressed disposing off the excavated stuff or sorting & stacking the
selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of
labour, tools & other appurtenaces required to complete the work. | Cum | 254.1 | 254.1 | 32.41 | False | None | None | False | None | False | 8235.381 | 0 |
| 2828495 | 91533 | None | 2.1.2 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in
layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of
machinery, curing, and all the other appurtenances required to complete the
work as per technical specifications. | Cum | 5947.2 | 5947.2 | 10.58 | False | None | None | False | None | False | 62921.376 | 0 |
| 2828496 | 91533 | None | 5.4 | Providing Size Stone masonry with hard stone in foundation & plinth with
Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6708.45 | 6708.45 | 11.24 | False | None | None | False | None | False | 75402.978 | 0 |
| 2828497 | 91533 | None | 5.6 | Providing and constructing laterite size stone masonry including cost
and conveyance of all materials curing etc complete as per specification
I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for
saturated dry samples - For Basement in CM 1:6 | Cum | 6770.4 | 6770.4 | 8.7 | False | None | None | False | None | False | 58902.48 | 0 |
| 2828498 | 91533 | None | 2.2.1 | Providing and laying in position Cement Concrete for all Foundation works.
The granite/trap/basalt crushed graded coarse aggregates and fine aggregates
as per relevant IS Codes machine mixed with super plasticizers laid in finished
layers, well compacted using needle vibrators, including all lead & lifts, cost
of all materials, quality confirming to the requirements of relevant IS codes,
labour, Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7230.05 | 7230.05 | 6.67 | False | None | None | False | None | False | 48224.4335 | 0 |
| 2828499 | 91533 | None | 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of
building , Road works, Water works, Irrigation works & super structure works
of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery curing
and all other appurtenances required to complete the work as per technical
specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregate | Cum | 8287.5 | 8287.5 | 13.46 | False | None | None | False | None | False | 111549.75 | 0 |
| 2828500 | 91533 | None | 2.4.1 | Providing and laying in position Cement Concrete for all Sub structures of
building, Irrigation works, Sub structure works of bridges, Drain works &
other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt
crushed graded coarse aggregates and fine aggregates as per relevant IS
Codes machine mixed with super plasticisers, laid in layers, well compacted
using needle vibrators, providing weep holes wherever necessary, including
all lead & lifts, cost of all materials of quality, confirming to the requirements
of relevant IS codes, labour, Usage charges of machinery, curing and all other
appurtenances required to complete the work as per technical specifications Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates | Sqm | 9606.0 | 9606.0 | 1.44 | False | None | None | False | None | False | 13832.64 | 0 |
| 2828501 | 91533 | None | 13.10.2 | Providing Fusion Bonded Epoxy Coating (FBEC) to TMT
Bars as per IS:13620 1993 specifications for a thickness of
175micron permissible variation of 50micron including
testing of coating. FREQUENCY OF TEST OF FUSION BONDED
EPOXY COAT a)Coating thickness shall be tested at a frequency
of not less than one full length bar every twenty bars for each size
b) Continuity of coating shall be determined by testing one full
length bar in every twenty bars for each size c) Coating thickness
over the whole of the coated bar section shall be determined by
sectioning and examining one bar in every 20t for each size. d)
For testing adhesion of coating, samples shall be selected from
a ch size according to the frequency given as: For all types of
bar Minimum 1 for every diameter or as directed by engineer
in charge The item is to be operated with prior approval of
Superintending Engineer 50 mm | Kg | 157.5 | 157.5 | 1693.91 | False | None | None | False | None | False | 266790.825 | 0 |
| 2828502 | 91533 | None | 1.10 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of
foundations and other similar works etc. in layers not exceeding 20cm in depth,
consolidating each deposited layer by ramming and watering, lead up to 50 m
and lift upto 1.5 m. | Cum | 168.0 | 168.0 | 9.01 | False | None | None | False | None | False | 1513.68 | 0 |
| 2828503 | 91533 | None | 1.12 | Supplying and Filling in Plinth with sand under floors foundation of Bridges including watering ramming consolidating and dressing complete | Cum | 2285.85 | 2285.85 | 9.28 | False | None | None | False | None | False | 21212.688 | 0 |
| 2828504 | 91533 | None | 6.4 | Providing Brick work with common burnt clay modular bricks of class
designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement
: 6 coarse sand) including cost of all materials, labour, scaffolding and
usage charges of machinery & other incidental charges complete as per
the direction of engineer incharge | Cum | 9094.05 | 9094.05 | 13.77 | False | None | None | False | None | False | 125225.0685 | 0 |
| 2828505 | 91533 | None | 8.9 | Providing 18 mm cement plaster in two coats under layer 12 mm thick
cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a
top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement
: 3 coarse sand) finished rough with sponge to brick masonry including
rounding off corners wherever required smooth rendering, providing and
removing scaffolding, including cost of materials, labour, curing complete
as per specifications and as per directions of Engineer-in-charge | Cum | 404.25 | 404.25 | 201.74 | False | None | None | False | None | False | 81553.395 | 0 |
| 2828506 | 91533 | None | 12.11 | Providing Honne wood frames of doors, windows, clerestory windows,
ventilators and other frames, wrought, framed or assembled including
making plaster groves (excluding cost of cement concrete and side clamps),
but including cost of materials, labour, usage charges complete as per
specifications. | Cum | 144977.7 | 144977.7 | 0.35 | False | None | None | False | None | False | 50742.195 | 0 |
| 2828507 | 91533 | None | 12.15 | Providing and fixing in position fully panelled Honne wood shutters for
doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm
wide top rail and stiles 100mm wide as per drawing and panels of 25mm
thick including cost of materials, labour, usage charges complete as per
specifications. ( excluding cost of fixtures ) | Sqm | 7816.2 | 7816.2 | 2.52 | False | None | None | False | None | False | 19696.824 | 0 |
| 2828508 | 91533 | None | 12.24 | Providing and fixing in position Mathi/Nandi wood fully panelled shutters
for windows with stiles and rails of 35mm. thick, 75mm wide in two
halves with panels of 25mm thick including cost of materials, labour
charges, usage charges complete as per specifications. (excluding cost of
fixtures) | Sqm | 7363.65 | 7363.65 | 4.32 | False | None | None | False | None | False | 31810.968 | 0 |
| 2828509 | 91533 | None | 9.17.2 | Providing and laying Vitrified tiles with thickness 9-10 mm in different
sizes with water absorption less than 0.08 % and conforming to I.S. 15622,
of approved make, in all colours & shade, over 12 mm thick bed of cement
mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry
@ 3.3 kg/ m2 including grouting the joint with white cement & matching
pigments etc. complete.ize of Tile 600x600 mM | Sqm | 1233.75 | 1233.75 | 49.6 | False | None | None | False | None | False | 61194.0 | 0 |
| 2828510 | 91533 | None | 8.25 | Distempering with oil bound washable distemper of approved brand
and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly
brooming the surface to remove all dirt, dust, mortar drops and foreign
matter including preparing the surface even and sand paper smooth, cost
of materials, labour complete as per specifications and as per directions
of Engineer-in-charge | Sqm | 143.85 | 143.85 | 209.13 | False | None | None | False | None | False | 30083.3505 | 0 |
| 2828511 | 91533 | None | 11.34B | Providing and fixing M.S. grills of required pattern in frames of windows
etc. with M.S. flats, square or round bars etc. including priming coat with
approved steel primer all complete. Fixed to openings /wooden frames
with rawl plugs screws etc | Sqm | 192.15 | 192.15 | 90.72 | False | None | None | False | None | False | 17431.848 | 0 |
| 2828512 | 91533 | None | 7.25.1 | Providing and fixing plain multipurpose cement board(Hight pressure
steam cured) with suitable screws for cement particle board in ceiling
etc. complete.6 mm thick Cement fiber board as per IS: 14862 | Sqm | 666.75 | 666.75 | 3.6 | False | None | None | False | None | False | 2400.3 | 0 |
| 2828513 | 91533 | None | 8.66 | Painting with black anti-corrosive bitumastic paint of approved brand
and manufacture to give an even shade :One coats on old work as per
specifications and as per directions of Engineer in charge. | Sqm | 66.15 | 66.15 | 3.6 | False | None | None | False | None | False | 238.14 | 0 |
| 2828514 | 91533 | None | 8.10 | Painting Two Coats on new Concrete Surfaces: Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered surfaces | Sqm | 114.45 | 114.45 | 2.16 | False | None | None | False | None | False | 247.212 | 0 |
| 2828515 | 91533 | None | 8.5 | Printing new letter and figures of any shade with synthetic
enamel paint black or any other approved colour to give an
even shade | cm | 1.68 | 1.68 | 2160.0 | False | None | None | False | None | False | 3628.8 | 0 |
| 2828516 | 91533 | None | 6.3.2 | Supplying capacitor type ceiling fan complete with down rod blades,
shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase
AC supply conforming to ISS-374- 1979 and with double ball bearing
system 56Sweep (1400 mm) Regular model | No | 3182.55 | 3182.55 | 1.0 | False | None | None | False | None | False | 3182.55 | 0 |
| 2828517 | 91533 | None | 1.1.4 | Supplying heavy gauge PVC conduit pipe . dia . mm thick
confirming to IS 2509 with suitable size bends, junction boxes,
adhesive paste etc , and fixing using inverted wood plugs in case of
RCC ceiling and RCC wall/ stone structure or rawl plugs in case of
brick walls and cement plastering the damaged portion using heavy
gauge saddles at an interval of 700mm using NF screws.40 mm dia 2.5 mm thick | Mtr | 156.45 | 156.45 | 20.0 | False | None | None | False | None | False | 3129.0 | 0 |
| 2828518 | 91533 | None | 1.9.6 | Supplying PVC flexible conduit pipe . mm dia fixing on surface
over inverted tapered wooden plugs or phill plugs or rawl plugs and
clamped using heavy gauge saddles at an interval of 300 mm using NF
screws and on either end of the pipe terminated completely 63 mm | Mtr | 72.45 | 72.45 | 24.0 | False | None | None | False | None | False | 1738.8 | 0 |
| 2828519 | 91533 | None | 2.1.5 | Supplying and wiring adopting loop system in existing PVC
Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) &
1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated
copper wire (confirming to IS-694: and latest amendments) with
a 6Amps flush type SP control switch shall be fixed on the existing
plastic sheet/ gang box, the other end of the wires shall be terminated
with sufficient loose length in a wood/PVC round block. complete for
each outlet Three outlet in a row, above 6Mts upto 10Mtr from tapping point to
out let via switches | Point | 1086.75 | 1086.75 | 1.0 | False | None | None | False | None | False | 1086.75 | 0 |
| 2828520 | 91533 | None | 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 1.5 mm | No | 27.3 | 27.3 | 60.0 | False | None | None | False | None | False | 1638.0 | 0 |
| 2828521 | 91533 | None | 1.4.7 | Supplying and fixing sheet Metal box made out of 18 SWG sheet
metal with necessary holes for cable/conduit entry as required with one
coat of primer of approved make etc.200 x 200 x 65 mm | No | 365.4 | 365.4 | 2.0 | False | None | None | False | None | False | 730.8 | 0 |
| 2828522 | 91533 | None | 1.6.1 | Supplying and flush mounting teak wooden box without front plank,
made of not less than 12 mm thick wood, after due groove cutting,
finishing with necessary cement plastering complete 12" x 12" x 3" (300 x 300 x 76 mm) | No | 126.0 | 126.0 | 2.0 | False | None | None | False | None | False | 252.0 | 0 |
| 2828523 | 91533 | None | 3.1.2 | Supplying 6A flush type socket and 6 A flush type SP switch either
surface/flush mounting in existing gang box or in 4mm thick plastic
sheet and fixing over a flush mounted wooden box and wiring using
necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 Way | No | 154.35 | 154.35 | 10.0 | False | None | None | False | None | False | 1543.5 | 0 |
| 2828524 | 91533 | None | 3.6.3 | Supplying and fixing of modular switch & connected accessories on
existing modular switch plate as per IS 3854 and IS 1293.6A Three Way socket | No | 179.55 | 179.55 | 10.0 | False | None | None | False | None | False | 1795.5 | 0 |
| 2828525 | 91533 | None | 3.7 | Supplying and fixing 32A security and energy saving DP switch
with key tag suitable to operate on 230 V, 50Hz AC supply &
completely wired on existing box | No | 678.3 | 678.3 | 1.0 | False | None | None | False | None | False | 678.3 | 0 |
| 2828526 | 91533 | None | 1.8.4 | Supplying and fixing of PVC casing and capping on the wall or ceiling
using necessary materials like bends, junction box, elbows, screws at
an interval of 300 mm as required 38 mm | No | 65.1 | 65.1 | 4.0 | False | None | None | False | None | False | 260.4 | 0 |
| 2828527 | 91533 | None | 11.11.7 | Supplying fixing of retrofit type LED bulb W with OPAL acrylic
diffuser comprising of LED source with CCT 6500 degree K CRI 70
efficacy 80 lumen per W life 25000 burning hours and Compliance to IS
10322/IEC 60598, LM 79 LM 80 The LED are driven by HF electronic
driver integrated in the system, with PF 0.95 power loss should 5 of
lamp Wage short circuit & open circuit protection to be integrated in the
circuit, THD less than 20 Life as per LM 79 The operating input voltage should be between 130 to 275 V BIS Approved and Tested by
NABL CPRI accredited laboratory with 2 years Warranty against any
manufacturing defect working under standard electrical condition | No | 447.3 | 447.3 | 2.0 | False | None | None | False | None | False | 894.6 | 0 |
| 2828528 | 91533 | None | 11.14.3 | upplying and fixing of slim box fitting, made out of CRCA Sheet
metal body with locking type holder completely wired. Excluding
Ballast & Fluorescent Tube. | No | 442.05 | 442.05 | 2.0 | False | None | None | False | None | False | 884.1 | 0 |
| 2828529 | 91533 | None | 6.3.2 | Supplying capacitor type ceiling fan complete with down rod blades,
shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase
AC supply conforming to ISS-374- 1979 and with double ball bearing
system | No | 3182.55 | 3182.55 | 2.0 | False | None | None | False | None | False | 6365.1 | 0 |
| 2828530 | 91533 | None | 2.8.A | Dismantling of existing structures like culverts, bridges, retaining
walls and other structure comprising of masonry, cement concrete,
wood work, steel work, including T&P and scaffolding wherever
necessary, sorting the dismantled material, disposal of unserviceable
material and stacking the serviceable material with all lifts and lead Cement Concrete Grade M-15 & M-20 | Cum | 754.95 | 754.95 | 10.49 | False | None | None | False | None | False | 7919.4255 | 0 |
| 2828531 | 91533 | None | 13.34 | Providing and Placing on terrace at all floor levels Polythylene water storage tank IS 12701 marked with cover and suitable locking arrangment and making necessary holes for inlet outlet and overflow pipes but without fittings and the base support for tank | Ltr | 9.45 | 9.45 | 750.0 | False | None | None | False | None | False | 7087.5 | 0 |
| 2828532 | 91533 | None | 13.31.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply, including all CPVC
plain & brass threaded fittings, including fixing the pipe with clamps at
1.00 m spacing. This includes jointing of pipes & fittings with one step
CPVC solvent cement and testing of joints complete as per direction of
Engineer in Charge.
Internal work - Exposed on wall 25 mm nominal dia Pipes | Mtr | 333.9 | 333.9 | 17.8 | False | None | None | False | None | False | 5943.42 | 0 |