createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1709115434429
version10
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee7500.00
emd22200000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose07-03-2024 15:00:00
tenderQueryClose29-02-2024 11:30:00
technicalBidOpen11-03-2024 11:00:00
publishedDate28-02-2024 18:28:32
publishedByPostKPTCL_EE1_TP_BNG
publishedByUserKPE11153 - RENUKA S
bidValidityPeriod180
noOfCalls1
preBidMeetingDate28-02-2024 17:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonRenuka S
splitEmdRequiredYnTrue
emdBankGuarantee21200000.00
emdCash1000000.00
bgValidityPeriod225
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08022274744
mobileNumber9480830121
tenderSupplierListNone
tenderSchedule
createdTs1709115434431
version13
createdDateNone
modifiedDateNone
tenderNumberKPTCL/2023-24/SS/WORK_INDENT668
titleEstablishing 2x150MVA, 220/66kV & 2X31.5MVA, 66/11kV sub-station at Banashankari 6th stage in Bengaluru South Taluk, Bengaluru Urban District along with running of 220kV & 66kV UG Cables and construction of 66kV Terminal Bay on Partial Turnkey Basis (excluding Supply of 11kV Switchgear) including Supply of all equipments /Materials including Mandatory spares, Erection (including Civil Works), of all materials/ equipments, Testing & Commissioning
descriptionEstablishing 2x150MVA, 220/66kV & 2X31.5MVA, 66/11kV sub-station at Banashankari 6th stage in Bengaluru South Taluk, Bengaluru Urban District along with running of 220kV & 66kV UG Cables and construction of 66kV Terminal Bay on Partial Turnkey Basis (excluding Supply of 11kV Switchgear) including Supply of all equipments /Materials including Mandatory spares, Erection (including Civil Works), of all materials/ equipments, Testing & Commissioning
categoryWORKS
categoryTextWorks
ecv2220014897.23
deptNameKarnataka Power Transmission Corporation Limited
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location4550
locationNameKPTCL CEE Corporate Office Tendering and Procurement Bengaluru
provisionalAmount2220014897.63
groupOverheadTotal220250813.8
fileNumberKPTCL/CEE/TP/220KV/Banashankari6thstagePartA/PTK/TLSS1548
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17091154350000NoneNoneSub-StationStation Supply Portion548759105.24
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
284100992080NoneSS1Station Supply Portion :Banashankari 6th Stage -For details and split up refer Technocommercial sheet POWER TRANSFORMERS: a. 150 MVA, 220/66/11 kV Power Transformer : 3 Ph, 50 Hz, Core type, 3 winding Transformer, Star/Star/Delta, Vector Group: YNyn0d11, OLTC, Bushing CT for Tertiary of ratio 1515/1A, 5P20, 15VA, ONAN/ONAF/OFAF with Fan control cubicle, RTCC Panel, Numerical RTCC panel with fibre optic temperature sensor, first filling of oil and 10% spare oil in non-returnable drums, etc., complete with 2x50% separate Radiator Bank on left side and terminal connector suitable for Single Drake ACSR/Double Drake ACSR on primary and secondary side of Transformer and Neutral connectors suitable for 2 numbers of 75 mm x 10 mm copper flats as per technical specification.Nos139611711.8139611711.82.0FalseNoneNoneFalseNoneFalse279223423.60
284101092080NoneSS2b. 31.5 MVA, 66/11 kV Transformer : 3 Ph, 50 Hz, Core type, 2 winding Delta/Star, Vector Group: DYn11, OLTC, ONAN/ONAF with Fan control cubicle, RTCC Panel, Numerical RTCC panel with fibre optic temperature sensor, first filling of oil and 10% spare oil in non-returnable drums, etc., complete with Terminal connector suitable for single Drake ACSR on primary side of Transformer and copper flat on 11 kV and neutral side as per technical specificationNos37438343.837438343.82.0FalseNoneNoneFalseNoneFalse74876687.60
284101192080NoneSS3FIRE FIGHTING EQUIPMENTS: a) Supply, Erection & Testing and Commissioning of Nitrogen Injection fire extinguishing system including fire exinguishing cubical, control box, online testing facility , etc as per specification for 220/66/11kV, 150MVA Power Transformer.Set1784036.11784036.12.0FalseNoneNoneFalseNoneFalse3568072.20
284101292080NoneSS4b) Supply, Erection & Testing and Commissioning of Nitrogen Injection fire extinguishing system including fire exinguishing cubical, control box, online testing facility , etc as per specification for 66/11kV, 31.5MVA Power Transformer.Set1347129.31347129.32.0FalseNoneNoneFalseNoneFalse2694258.60
284101392080NoneSS5SF-6 CIRCUIT BREAKER: SF6 type with terminal connector suitable for Al.tube /Conductor with spring / semi-pneumatic / pneumatic type operating mechanism and marshalling box along with associated support structure etc., as per technical specification. a. 220kV, 2500A, 50kA ClassSet1980358.61980358.65.0FalseNoneNoneFalseNoneFalse9901793.00
284101492080NoneSS6b. 66kV, 1250A, 40kA ClassSet829551.8829551.87.0FalseNoneNoneFalseNoneFalse5806862.60
284101592080NoneSS7c. 66 kV, 2000A, 40A ClassSet829551.8829551.83.0FalseNoneNoneFalseNoneFalse2488655.40
284101692080NoneSS8ISOLATORS: Isolators and Terminal Connectors, as per Technical Specification including solid core cylindrical post insulators. (1) 220kV, 1250A, 40kA for three seconds short time current rating, electrically cum manually operated double break type disconnects with solid core insulators, terminal connector suitable for Al. tube/conductor, marshalling box etc., complete as per technical specification a) Upright with Earth Switch Live Point Height (LPH) 5750 mm.Set668210.4668210.42.0FalseNoneNoneFalseNoneFalse1336420.80
284101792080NoneSS9b.Upright mounting type without earth Switch i. Live Point Height 8250mmSet566836.6566836.612.0FalseNoneNoneFalseNoneFalse6802039.20
284101892080NoneSS10ii.Upright mounting type without earth Switch Live Point Height 5750mmSet559697.6559697.66.0FalseNoneNoneFalseNoneFalse3358185.60
284101992080NoneSS11iii.Under hung mounting type without earth switch(130000mm Mounting height)Set585398.0585398.04.0FalseNoneNoneFalseNoneFalse2341592.00
284102092080NoneSS122.66kV, 2000A, 40kA double break electrically cum manually operated isolators with solid core insulator, terminal connector suitable for Al.tube / conductor, marshalling box etc., complete as per technical specification. (For 66kV side of 150 MVA transformer, Bus coupler and inter connecting bay). a. Upright mounting type without Earth Switch i Live Point height -5500mmSet298410.2298410.27.0FalseNoneNoneFalseNoneFalse2088871.40
284102192080NoneSS13ii. Upright without earth switch Live point height - 4250mmSet291271.2291271.24.0FalseNoneNoneFalseNoneFalse1165084.80
284102292080NoneSS14b. Under hung without Earth switch- LPH -13125mmSet308404.8308404.82.0FalseNoneNoneFalseNoneFalse616809.60
284102392080NoneSS153 66 kV, 1250 A, 40 kA double break electrically cum manually operated isolators with solid core insulator, terminal connector suitable for Al. tube/conductor, marshalling box etc., complete as per technical specification a. Upright with earth Switch (LPH:4250mm).Set342672.0342672.05.0FalseNoneNoneFalseNoneFalse1713360.00
284102492080NoneSS16b. Upright Mounting type without earth Switch (i) Live point height 5500mmSet298410.2298410.215.0FalseNoneNoneFalseNoneFalse4476153.00
284102592080NoneSS17ii Live point height without earth switch 4250mmSet291271.2291271.24.0FalseNoneNoneFalseNoneFalse1165084.80
284102692080NoneSS18c. Underhung mounting type without Earth Switch-LPH-13125mm Terminal connectors for Isolators :- Rigid type terminal connector suitable for Drake ACSR -168 nos, Rigid type terminal connector suitable for Double Drake ACSR-42 nos Flexible type Terminal connector suitable for 63mm Al.Pipe - 75 nos. Flexible type Terminal connector suitable for 50mm Al.Pipe -93 nosSet308404.8308404.84.0FalseNoneNoneFalseNoneFalse1233619.20
284102792080NoneSS19CURRENT TRANSFORMER :Oil filled Current Transformer 0.2s class with terminal connector suitable for Al.tube/conductor with marshalling box etc., complete as per technical specification. (i) 220 kV Class : 1200-800-400-300/1-1-1 A plus 2 cores of 1200/1 A (2 Nos. of Main CT's are used as NCT)Nos419773.2419773.217.0FalseNoneNoneFalseNoneFalse7136144.40
284102892080NoneSS2066 kV Class : 1600-1000/1-1-1 A (Required for 150MVA Transformer & Bus Coupler) (2 Nos. of Main CT's are used as NCT)Nos157058.0157058.011.0FalseNoneNoneFalseNoneFalse1727638.00
284102992080NoneSS2166 kV Class : 400-200/1-1-1 A (Required for 31.5MVA, 66/11kV Transformer)Nos115651.8115651.86.0FalseNoneNoneFalseNoneFalse693910.80
284103092080NoneSS2266 kV Class : 1200-800/1-1-1 ANos157058.0157058.015.0FalseNoneNoneFalseNoneFalse2355870.00
284103192080NoneSS2311 kV NCT (Outdoor) : 2000-1200/1-1-1 A (of similar rating as incomer of 11kV Switchgear) (Required for 31.5MVA, 66/11kV Tr) NOTE: 1. All the current transformers in each kV class shall be of one and the same make for interchangeability and reliability of performance. 2. The make and characteristic of 11kV NCT should be same as that of the incomer CT of 11kV Switchgear. To ensure this the 11kV NCT should be procured from the supplier of 11kV CTs to 11kV Switchgear only.Nos69962.269962.22.0FalseNoneNoneFalseNoneFalse139924.40
284103292080NoneSS24VOLTAGE TRANSFORMER: Single phase, oil filled, outdoor type VT with terminal connector suitable for Al. tube/ conductor with marshalling box etc., complete as per technical specification. (i)  220kV, VTs of Ratio 220kV/root3/110V/root3-110V/root3/110V/root3, For Metering Core - 300VA, Accuracy 0.2For Protection Core 1 & 2 - 200VA, Accuracy 3PNos328394.0328394.06.0FalseNoneNoneFalseNoneFalse1970364.00
284103392080NoneSS25ii. 66kV VTs of Ratio 66kV/root3/110V/root3-110V/root3-110V/root3 Core-1-Metering 300VA, Accuracy 0.2 Core-2-Protection 200VA, Accuracy 3P Core-3-Protection Open Delta, 50VA, Accuracy-3PNos117079.6117079.66.0FalseNoneNoneFalseNoneFalse702477.60
284103492080NoneSS26SURGE ARRESTOR :with Terminal Connector suitable for Drake ACSR : 198 kV Metal Oxide with surge counter Arrestor class : Station Medium Duty (SM) - Discharge Class 3 - for Transformer & UG CableNos69962.269962.212.0FalseNoneNoneFalseNoneFalse839546.40
284103592080NoneSS2760 kV Metal Oxide with surge counter Arrestor class : Discharge Class 3 (Station Medium Duty (SM)) - for Transformer & UG Cable -Class III Remarks: All the Surge Arresters are with Surge Monitors & Insulating BaseNos39978.439978.427.0FalseNoneNoneFalseNoneFalse1079416.80
284103692080NoneSS28Control &Relay Panel compatible to IEC 61850, communication protocol for Sub-station Automation System complete as per technical specification 220 kV Panel for UG cable - Type 2L (As per Annexure RPPI-SAS)Nos2327314.02327314.02.0FalseNoneNoneFalseNoneFalse4654628.00
284103792080NoneSS29220/66/11 kV Transformer Panel - Type 2T6 (As per Annexure RPP2-SAS)Nos2584318.02584318.02.0FalseNoneNoneFalseNoneFalse5168636.00
284103892080NoneSS30220 kV Panel for Bus Coupler - Type 2BC (As per Annexure RPP1-SAS)Nos1590569.21590569.21.0FalseNoneNoneFalseNoneFalse1590569.20
284103992080NoneSS31220kV Bus Bar Protection - Type 2BBA (Asper Annexure RPP3-SAS)Nos3658023.63658023.61.0FalseNoneNoneFalseNoneFalse3658023.60
284104092080NoneSS3266 kV Panel for UG Cable - Type 6L (As per Annexure RPP4-Cable-SAS)Nos1800455.81800455.84.0FalseNoneNoneFalseNoneFalse7201823.20
284104192080NoneSS3366kV Bus Coupler - Type 6BC (As per Annexure RPP6-SAS)Nos1376399.21376399.21.0FalseNoneNoneFalseNoneFalse1376399.20
284104292080NoneSS3466/11kV Transformer - Type 6T1 (As per Annexure RPP5-SAS)Nos2340164.22340164.22.0FalseNoneNoneFalseNoneFalse4680328.40
284104392080NoneSS35Control and Relay Panel: Simplex type control and relay panels complete as per specifications: For 66kVUG Cable with Cable Differential relay Note : 1.All the C&R panels and associated panels shall be of one and the same make for uniformity and interchangability of components. 2.The accuracy class of metering core of CTs & ETV meter of C&R panels shall be 0.2s accuracy class irrespective of what has been indicated else where in the bid document. 3.The Electronic Tri-vector meters of 0.2S accuracy class with ABT & TOD features, DLMS protocol energy meter has to be provided.Nos755306.2755306.21.0FalseNoneNoneFalseNoneFalse755306.20
284104492080NoneSS3611 kV Panel for Overhead Line - Type 1L Provision for 2 feeders to be made in one panel (As per Annexure RPP7-SAS): provision for 2 capacitor feeder to be made in one panel, provision for 1 line feeder & 1 Bus Coupler to be made in one panel)Set1156518.01156518.011.0FalseNoneNoneFalseNoneFalse12721698.00
284104592080NoneSS37Sub-Station Automation System: Complete Sub-station automation system including hardware and software for Sub-station and for operation from remote control centre along with associated equipments. As per Annexure- SAS of Relay & Protection Panels and Sub station Automation Specification. Along with armoured OFC (Redundant) & Ethernet switches, separate station Auxiliary panel along with furniture etc., as per specifications.Set18781281.218781281.21.0FalseNoneNoneFalseNoneFalse18781281.20
284104692080NoneSS38Rigid Bus with Taps & Clamps: Aluminium tube conforming to 6340WPS of IS-5082/1969 ( BS 1600-Sch40) of following A. 75mm Size--- 220kV SideMtr1871.481871.48360.0FalseNoneNoneFalseNoneFalse673732.80
284104792080NoneSS3963mm size -TotalMtr1713.361713.361140.0FalseNoneNoneFalseNoneFalse1953230.40
284104892080NoneSS40D. 50mm Size connecting isolator to vertical tap & also for connecting equipments to equipments- 66kV SideMtr1449.041449.04216.0FalseNoneNoneFalseNoneFalse312992.640
284104992080NoneSS41E. Inverted ‘V’ taps made of 63mm Aluminium Tube (BS-1600) of 2500mm vertical height for vertical portion and cross bus on 220kV Side with rounded off end.Nos5370.185370.1830.0FalseNoneNoneFalseNoneFalse161105.40
284105092080NoneSS42F. Inverted ‘V’ Taps made of 63mm Al tube (BS-1600) of 1250mm vertical height for vertical portion and auxiliary bus on 66kV side with rounded off end (for I.C. bay + 150MVA transformer +BC)Nos4408.484408.4824.0FalseNoneNoneFalseNoneFalse105803.520
284105192080NoneSS43G.Straight taps made of 50mm Aluminium Tube (BS-1600) of 1250mm vertical height for vertical portion and cross bus on 66kV side with rounded off end.Nos2761.22761.233.0FalseNoneNoneFalseNoneFalse91119.60
284105292080NoneSS44H. Post Insulator Clamp suitable for 75mm Al pipe and post Insulators Solid Core Type. 220kV Side i) Rigid typeNos2204.242204.2430.0FalseNoneNoneFalseNoneFalse66127.20
284105392080NoneSS45ii) Expansion typeNos6279.966279.9624.0FalseNoneNoneFalseNoneFalse150719.040
284105492080NoneSS46I. Post Insulator Clamp suitable for 63mm Aluminium Pipe and post insulators solid core type 66kV Side i) Rigid TypeNos2068.542068.5439.0FalseNoneNoneFalseNoneFalse80673.060
284105592080NoneSS47ii).Expansion TypeNos5838.645838.6430.0FalseNoneNoneFalseNoneFalse175159.20
284105692080NoneSS48iii).Sliding TypeNos1747.581747.5873.0FalseNoneNoneFalseNoneFalse127573.340
284105792080NoneSS49J. Corona Bell Suitable for Aluminium Pipe of Size i) 63mm on 66kV SideNos728.06728.0618.0FalseNoneNoneFalseNoneFalse13105.080
284105892080NoneSS50ii). 75mm on 220kV sideNos801.22801.2212.0FalseNoneNoneFalseNoneFalse9614.640
284105992080NoneSS51G. Terminal connector suitable for 50 mm Aluminium tube flexible to connect bus to isolator.Nos3523.483523.4812.0FalseNoneNoneFalseNoneFalse42281.760
284106092080NoneSS52Welding sleeve suitable for 50mm Al.tubeNos1951.721951.723.0FalseNoneNoneFalseNoneFalse5855.160
284106192080NoneSS53BUS BAR FORMATION : i) Drake ACSR-(220kV side-1.5km & 66kV side-3.00km)Kms456660.0456660.04.5FalseNoneNoneFalseNoneFalse2054970.00
284106292080NoneSS54ii) Earth wire:7/3.15 mm steel with clamps and lugsKms103840.0103840.00.5FalseNoneNoneFalseNoneFalse51920.00
284106392080NoneSS55INSULATORS: Cylindrical Solid core post Insulator as per IS :5350,Part-II & III & as per technical specification: 1) For 220kV side -2 units/stack a) Post Insulators of Rigid Bus -54Stacks & b) Post Insulators for 150 MVA Transformer -6StacksStack32336.7232336.7260.0FalseNoneNoneFalseNoneFalse1940203.20
284106492080NoneSS56ii) For 66kV Side-1 Unit/Stack a) Post Insulators of Rigid Bus & IC Bays-154Stacks & b) Post Insulators for 150 MVA Transformer -6Stacks & 31.5MVA Tr-6StacksStack6412.126412.12166.0FalseNoneNoneFalseNoneFalse1064411.920
284106592080NoneSS57Disc Insulators String. 1. 120kN Disc InsulatorNos946.36946.362280.0FalseNoneNoneFalseNoneFalse2157700.80
284106692080NoneSS582. 90KN Disc InsulatorNos699.74699.74468.0FalseNoneNoneFalseNoneFalse327478.320
284106792080NoneSS59Insulator Hardware & Clamps: i. Bolted Type tension clamp to suit Drake ACSR 220kV side Transformer Bays-12Nos 66kV side Transformer Bays-36NosNos2957.082957.0848.0FalseNoneNoneFalseNoneFalse141939.840
284106892080NoneSS60ii. Bolted type Double Tension clamp to suit Double Drake ACSR 220kV side -Line & BC Bay-18Nos 66kV side 150MVA Transformer & BC Bay-30NosNos5118.845118.8448.0FalseNoneNoneFalseNoneFalse245704.320
284106992080NoneSS61iii. Bolted type suspension clamp to suit Drake ACSR 220kV side Transformer Bays-6Nos 66kV side Transformer & line Bays-24NosNos1797.141797.1430.0FalseNoneNoneFalseNoneFalse53914.20
284107092080NoneSS62iv. Bolted type suspension clamp to suit Double Drake ACSR 220kV side Line 2BC Bays-12Nos 66kV side 150MVA Transformer & BC Bays-12NosNos3285.123285.1224.0FalseNoneNoneFalseNoneFalse78842.880
284107192080NoneSS63v. C Type Wedge connector (T-Type) suitable for Drake to Drake ACSR. 220kV side Transformer Bays-24Nos 66kV side 66/11kV Transformer & 66kV line Bays-60NosNos2719.92719.984.0FalseNoneNoneFalseNoneFalse228471.60
284107292080NoneSS64vi.C Type Wedge connector suitable for Double Drake to Double Drake 220kV side Line bays & BC bays-18Nos For 66kV side of 150MVA transformer +BC-33NosNos7279.427279.4251.0FalseNoneNoneFalseNoneFalse371250.420
284107392080NoneSS65viii.PI Clamp suitable for post insulator & Drake ACSR 220kV Side of 150 MVA transformer-6Nos & 66kV side of 31.5MVA transformer-6NosNos1191.81191.812.0FalseNoneNoneFalseNoneFalse14301.60
284107492080NoneSS66x.PI clamp suitable for post insulator and double drake ACSR( for 66kV side of 150MVA TransformerNos1806.581806.586.0FalseNoneNoneFalseNoneFalse10839.480
284107592080NoneSS67xi. Spacers for Double Drake ACSR (Flexible & Rigid type)Nos661.98661.98300.0FalseNoneNoneFalseNoneFalse198594.00
284107692080NoneSS68xii. Clamp (T-Type) suitable for 63mm Al.tube to Double Drake Conductor - 220 kV LinesNos2338.762338.7612.0FalseNoneNoneFalseNoneFalse28065.120
284107792080NoneSS69xiii. Clamp (T-Type) suitable for 50 mm Al.tube to Double Drake ACSR- 66 kV side of 150 MVA Trf.Nos1993.021993.0212.0FalseNoneNoneFalseNoneFalse23916.240
284107892080NoneSS70xiv. Terminal connector suitable for 220 kV cable termination and 63mm Al.tube (Rigid/Expansion type).Nos2338.762338.766.0FalseNoneNoneFalseNoneFalse14032.560
284107992080NoneSS71xv. Terminal connector suitable for 66kV cable termination and Drake ACSRNos1314.521314.5212.0FalseNoneNoneFalseNoneFalse15774.240
284108092080NoneSS72a) Auxiliary Transformers: Auxiliary Transformer with copper windings & oil, cable termination type on both HT & LT outdoor type with off load tap changer in steps of 2.5 % as per specification. 250kVA, 11kV / 433V Auxiliary Transformers, 3Phase, Delta / Star-Dyn11 including LT Distribution Box,HRC fuse and metering etc., complete set.Set541917.36541917.362.0FalseNoneNoneFalseNoneFalse1083834.720
284108192080NoneSS73b. LTAC Panel (Indoor), 415 V as per technical specification comprising of voltmeter and ammeter, 2 I/C ACB, 800A + 2 O/G SFU, 200A + 8 O/G SFU, 100A + 14 O/G SFU, 63A + 12 O/G, 32A + 1B/C SFU, 800A + 1DG change over switch 300A etc., complete as per technical specification.Set728178.0728178.01.0FalseNoneNoneFalseNoneFalse728178.00
284108292080NoneSS74LT Power Cable from Auxiliary Transformers to LTAC Panel 1.1kV PVC Insulated 240Sq.mm Al. Cable3.5core with Glands / Lugs / FerrulesKms1017945.881017945.880.1FalseNoneNoneFalseNoneFalse101794.5880
284108392080NoneSS75PVC insulated aluminium power cable (AC Supply for lighting etc.,) 70 Sq.mm 3.5 Core, with glands / lugs / ferrulesKms375136.16375136.162.0FalseNoneNoneFalseNoneFalse750272.320
284108492080NoneSS76AC Distribution box (Out door) Double front type, 24 terminals, 1200 x1350 x600 mm, Two I/C of 100 A MCCB 20 KA + 24 O/G 16 A MCB +2 O/G of 100 A HRC FuseNos144207.8144207.85.0FalseNoneNoneFalseNoneFalse721039.00
284108592080NoneSS77AC Distribution box (Out door) Single front type, 6 terminals 750 x1350 x300 mm, one I/C of 100 A, MCCB 20 KA+ 6 O/G 16 A MCB +1 O/G of 100 A HRC Fuse ( for 220kV Station)Nos51400.851400.84.0FalseNoneNoneFalseNoneFalse205603.20
284108692080NoneSS78AC distibution Box (out door type): AC distribution box single front type, 6 terminal 1200x1350x300mm, 1 IC of 100Amps MCCB 20kA+6 OG MCB 16Amps+1 OG of 100A, HRC fuse. ( For 66kV Station)Nos85668.085668.01.0FalseNoneNoneFalseNoneFalse85668.00
284108792080NoneSS79DG set : Diesel Generating set- 3 Ph, 415V, 0.8PF, 62.5kVA, mounted on a Base Frame,complete with inbuilt fuel tank and battery 1 no.12V & inbuilt standard manual Control Panel with acoustic enclosure - NAL Approved D.G. Set 62.5 kVA capacity with AMF panel as per Specification including erection.Set1286902.11286902.11.0FalseNoneNoneFalseNoneFalse1286902.10
284108892080NoneSS80STATION BATTERY & BATTERY CHARGER : A) STATION BATTERY : 220 V, 300 AH, Battery set consisting of 110 No. cells per bank as per technical specificationsSet2910195.22910195.22.0FalseNoneNoneFalseNoneFalse5820390.40
284108992080NoneSS81B) BATTERY CHARGER : Battery charger suitable for '2 X 220 V, 300 AH, with float (2 Nos) & 2 Nos of boost battery charger including control panels, change over arrangements etc., complete along with two separate DC distribution panel (indoor) 1I/C+20 O/G SFU 60 A+20 O/G SFU 30 A as per technical specifications.Set1137956.61137956.61.0FalseNoneNoneFalseNoneFalse1137956.60
284109092080NoneSS82PVC insulated Copper Control Cable with Lugs / Ferrules. 1.1 kV class. Size of cable: a. 19 Core 2.5 Sq.mm. Copper Control CablesKms619500.0619500.06.5FalseNoneNoneFalseNoneFalse4026750.00
284109192080NoneSS8314 Core 2.5 Sq.mm. Copper Control CablesKms492060.0492060.011.0FalseNoneNoneFalseNoneFalse5412660.00
284109292080NoneSS8410 Core 2.5 Sq.mm. Copper Control CablesKms369340.0369340.03.0FalseNoneNoneFalseNoneFalse1108020.00
284109392080NoneSS857 Core 2.5 Sq.mm. Copper Control CablesKms351640.0351640.04.0FalseNoneNoneFalseNoneFalse1406560.00
284109492080NoneSS865 Core 2.5 Sq.mm. Copper Control CablesKms293820.0293820.01.5FalseNoneNoneFalseNoneFalse440730.00
284109592080NoneSS874 Core 2.5 Sq.mm Copper Control CablesKms167560.0167560.013.3FalseNoneNoneFalseNoneFalse2228548.00
284109692080NoneSS884 Core 6.0 Sq.mm. Copper Control CablesKms291460.0291460.011.5FalseNoneNoneFalseNoneFalse3351790.00
284109792080NoneSS894 Core 16.0 Sq.mm. Copper Control Cables( ACDB to Yard Light Cubicle)Kms660800.0660800.02.0FalseNoneNoneFalseNoneFalse1321600.00
284109892080NoneSS904 Core 4.0 Sq.mm. Copper Control CablesKms208860.0208860.06.0FalseNoneNoneFalseNoneFalse1253160.00
284109992080NoneSS912 Core 6.0 Sq.mm. Copper Control CablesKms181720.0181720.00.2FalseNoneNoneFalseNoneFalse36344.00
284110092080NoneSS922 Core 2.5 Sq.mm Copper Control Cables ( Yard light cubicle to LED fittings)Kms110920.0110920.02.51FalseNoneNoneFalseNoneFalse278409.20
284110192080NoneSS932PX0.5sq mm screened cableKms66080.066080.05.0FalseNoneNoneFalseNoneFalse330400.00
284110292080NoneSS9412PX0.5sq mm screened cable[ 8p + 4P]Kms155760.0155760.00.5FalseNoneNoneFalseNoneFalse77880.00
284110392080NoneSS956PX0.5sq mm screened cable[4P + 2P]Kms90860.090860.00.25FalseNoneNoneFalseNoneFalse22715.00
284110492080NoneSS9611kV UG Cable with the required cable terminations: 11kV XLPE 95Sq.mm Aluminium Cable-3 Core (For two auxiliary transformers from the 11kV Switchgear of 66/11kV Transformer)Mtr1049.81049.8200.0FalseNoneNoneFalseNoneFalse209960.00
284110592080NoneSS9711kV XLPE Cable, 1000 Sq.mm Aluminium Cable 3x4 runs of IC x 1000 Sq.mm cable from 66/11kV Transformers to 11kV SwitchgearMtr1398.31398.31500.0FalseNoneNoneFalseNoneFalse2097450.00
284110692080NoneSS9811kV XLPE 400 Sq.mm Aluminium Cable 3 Core to be run from 11kV Switchgear of 66/11kV Transformer to 11kV Capacitor bankMtr2945.842945.84100.0FalseNoneNoneFalseNoneFalse294584.00
284110792080NoneSS99Cable Termination Kit suitable for following sizes as per Technical Specification Heat shrinkable type Cable termination kits suitable for 1 x 1000Sq.mm XLPE cable (Out door type)Nos4790.84790.824.0FalseNoneNoneFalseNoneFalse114979.20
284110892080NoneSS100Heat shrinkable type Cable Termination kits suitable for 1x1000Sq.mm XLPE Cable(Indoor Type)Nos4493.444493.4424.0FalseNoneNoneFalseNoneFalse107842.560
284110992080NoneSS101Heat shrinkable type Cable Termination kits suitable for 3x400Sq.mm Cable for Cpacitor Bank (Outdoor Type)Nos6322.446322.444.0FalseNoneNoneFalseNoneFalse25289.760
284111092080NoneSS102Heat shrinkable type Cable Termination kits suitable for 3x400Sq.mm Cable for Cpacitor Bank (IndoorType)Nos5681.75681.74.0FalseNoneNoneFalseNoneFalse22726.80
284111192080NoneSS103Heat shrinkable type Cable Termination kits suitable for 3x95Sq.mm Cable(Indoor Type)Set4417.924417.924.0FalseNoneNoneFalseNoneFalse17671.680
284111292080NoneSS104FIRE FIGHTING EQUIPMENTS WITH NECESSARY MOUNTING STANDS Mechanical Foam Extinguisher Type: i. 50 LtrsNos11932.1611932.168.0FalseNoneNoneFalseNoneFalse95457.280
284111392080NoneSS105Mechanical Foam Extinguisher Type: ii. 09 LtrsNos4859.244859.248.0FalseNoneNoneFalseNoneFalse38873.920
284111492080NoneSS106Water type (gas pressure type) 9 Ltr. capacityNos2953.542953.5410.0FalseNoneNoneFalseNoneFalse29535.40
284111592080NoneSS107Carbon Dioxide Type 4.5 KgsNos10255.3810255.3810.0FalseNoneNoneFalseNoneFalse102553.80
284111692080NoneSS108Sand type G.I Buckets 9 Ltr. CapacityNos711.54711.5416.0FalseNoneNoneFalseNoneFalse11384.640
284111792080NoneSS109Steel stands.Nos2787.162787.164.0FalseNoneNoneFalseNoneFalse11148.640
284111892080NoneSS110Station and Yard Lighting (Outdoor & Indoor) & Lightning Protection 220kV & 66kV side: Supply, Erection & Civil portions: i. 11No's of Lightning / Lighting Mast (LM) are proposed for lightning protection and for illumination of the station Yard. The quantity of lightning / lighting mast indicated are located such that the entire station yard with equipments is protected against lightning. However any additional lighting masts may be provided for sufficient illumination of yard, if necessary. The design of lighting outdoor & indoor is also in the scope of the bidder as specified elsewhere in the technical specification.The scope also includes supply & erection of lighting fixtures, lighting mast panels with timers, contactors, control cables etc., Design of Station yard illumination in confirmity with the illumination levels mentioned in the technical specification, supply & erection of station yard illumination materials /equipment including lamp post(fabricated galvanised structures), Illumination fittings, control gears, UG/OH cables, conduit pipes, control boxes etc,. including necessary civil works, completeNo107272.73107272.7311.0FalseNoneNoneFalseNoneFalse1180000.030
284111992080NoneSS111CAPACTOR BANK: Design, Engineering, supply, erection of Capacitor Bank, star connected, Double Bank with internal fuses, terminal connectors with suitable neutral CT and station class LAs, 0.2% series reactor on neutral side with mounting structures for NCT, Capacitor Bank, station class LAs, Series reactor etc,. complete as per specification 12.1kV, 5.8 MVAR Capacitor bank with series reactor, NCT, LA etc as per specificationSet1349271.01349271.04.0FalseNoneNoneFalseNoneFalse5397084.00
284112092080NoneSS11211kV Isolator structure for Capacitor Bank- 11kV Double Break Isolator 400A, 25KA 14Nos for feeders & 2Nos. for Auxiliary TransformerSet25086.825086.816.0FalseNoneNoneFalseNoneFalse401388.80
284112192080NoneSS11311kV Double Break Isolator 400A, 25KA 4Nos with lattice type mounting structure for 11kV capacitor bankSet25086.825086.84.0FalseNoneNoneFalseNoneFalse100347.20
284112292080NoneSS114Supplying of Double pole structure with 9Mts. RCC poles,145Kg WL and with provision for fixing 11 kV 400 A Roaster single break isolators & provision for fixing 9kV lightning arrestors complete set with wiring materials. 14Nos for feeder & 2Nos for Auxiliary transformerSet38306.3438306.3416.0FalseNoneNoneFalseNoneFalse612901.440
284112392080NoneSS115Providing of Survelliance System: Smart Surveillance system (CCTV): using PTZ & fixed cameras, OFC monitoring system, HMI, etc as per bid specification. Note: The requirement of materials will be furnished by SEE, SCADA, Bangalore a) PTZ Camera: Speifications: Lens type-Auto Focus with optical Zoom of 30x, Digital Zoom+10x. Pan Angle:360 degree endless . Tilt angle:210 degrees with e-flip/higher. Zoom:30X Optical and 12X Digital Mode:Day & Night. Image size:-Full HD. streaming:High speed Weather Proof:IP 66 complaint. Network Protocol:TCP/IP should be compliant of any other protocol required. Connectivity:Cat 6/Optical fibre. Ethernet:10 Base-T/100 Base-TX (RJ45) Power source:Both self powered & externally powered.Nos.79475.3679475.365.0FalseNoneNoneFalseNoneFalse397376.80
284112492080NoneSS116Fixed Camera: Speifications: Lens type:-Bi-focal auto iris with 10x digital zoom. Mode:Day/Night Image size:720x486 (NTSC). Streaming:High Speed. Weather proof:IP 66 complaint Network Protocol:TCP/IP should be complaint of any other protocol required. Connectivity:Cat 6/optical fibre Ethernet:10Base-t/100Base-TX(RJ45) Power source:both Self powered/externally powered.Nos14144.6614144.668.0FalseNoneNoneFalseNoneFalse113157.280
284112592080NoneSS117HMI (Industrial Grade PC) Operating System : Windows 10 Professional CPU : Intel i7 quad core processor or latest RAM : 32 GB or higher Network : TCP/IP Graphics adaptor : NVIDA Quadra digital video pipeline or higher Hard disk : 1.5 TB (500x3) RAID 1 configuration External drives : BluRay RW and DVD RW Monitor : 24 inch dual screen Keyboard/Mouse : Wireless Network adaptor LAN switch Fibre LIUNos3346472.923346472.921.0FalseNoneNoneFalseNoneFalse3346472.920
284112692080NoneSS118OFC: 6F Armoured Multimode with LIU along with required number of SC/ST connectors and accesoriesSet68152.0868152.081.0FalseNoneNoneFalseNoneFalse68152.080
284112792080NoneSS119Equipments required for establishing SCADA communication as per KPTCL specification:- SDH Equipment : (STM-16 MADM up to 3 MSP PROTECTED DIRECTIONS) - BASE equipment (common cards, cross connect/ control cards, optical basecards, power supply cards, power cabling, other hardware and accessories including sub racks, patch cord, DDF ETC fully equipped excluding optical interface & tributory cards 3 Multiple Section Protection (MSP)Nos583756.62583756.621.0FalseNoneNoneFalseNoneFalse583756.620
284112892080NoneSS120Optical Interface Transceiver (S16.1 SFP (30KM)Nos1854.961854.962.0FalseNoneNoneFalseNoneFalse3709.920
284112992080NoneSS121Tributory Interface EI Interface card (Min. 16 interfaces per card)-3 MSpNos55126.0655126.062.0FalseNoneNoneFalseNoneFalse110252.120
284113092080NoneSS1221x1000 base LX SFP (GIGABIT ETHERNET INTERFACES 10/100 MBPS WITH LAYER-2 SWITCHING)Nos1164.661164.661.0FalseNoneNoneFalseNoneFalse1164.660
284113192080NoneSS123Ethernet Interface - 10/100 Mbps with layer-2 switching (minimum 2X1 Gbps+4x100/10 Mbps ports) without SFP-3MSP.Nos63223.2263223.222.0FalseNoneNoneFalseNoneFalse126446.440
284113292080NoneSS124Cabinet Equipment to house SDH equipment + Optical cards+Tributary Cards, Drop/Insert MUX equipments & DACS equipment.Set41229.241229.21.0FalseNoneNoneFalseNoneFalse41229.20
284113392080NoneSS125Digital Tele Protection Coupler 8 independent command channels with 220V DCNos341244.2341244.22.0FalseNoneNoneFalseNoneFalse682488.40
284113492080NoneSS12648V, 200 AH Float cum boost Charger, 75 ANos328394.0328394.01.0FalseNoneNoneFalseNoneFalse328394.00
284113592080NoneSS12748V, 200AH Battery Set Note : STM-16 equipment supplied under the subject work shall be of same make & model as supplied for KPTCL FOTE under Rliable communication OPGW project of KPTCLSet432115.2432115.21.0FalseNoneNoneFalseNoneFalse432115.20
284113692080NoneSS128Materials for new bay integration to existing SCADA panel a) Multi Functional Transducer (MFT) 0.2S classNo5752.55752.51.0FalseNoneNoneFalseNoneFalse5752.50
284113792080NoneSS129b) Opto Coupler (220 or 110V DC)No1548.161548.161.0FalseNoneNoneFalseNoneFalse1548.160
284113892080NoneSS130c) Current Cable-Copper core with 4.0sqmm cross section mutlistrand 4 core for CT Termination (4 core-2 runs)Mtr208.86208.865.0FalseNoneNoneFalseNoneFalse1044.30
284113992080NoneSS131d)Voltage Cables-Copper core with 2.5sqmm cross section mutlistrand 4 core for PT TerminationMtr167.56167.565.0FalseNoneNoneFalseNoneFalse837.80
284114092080NoneSS132e) Signal/communication Cables-Armoured copper 10C x 0.5 Sq mm mutlistrand 10coreMtr168.74168.74500.0FalseNoneNoneFalseNoneFalse84370.00
284114192080NoneSS133f) 10C X 1.5 Sq mm multistrand, conforming to KPTCL specificationMtr182.9182.9500.0FalseNoneNoneFalseNoneFalse91450.00
284114292080NoneSS134Digital Input Card with cableNo44521.444521.43.0FalseNoneNoneFalseNoneFalse133564.20
284114392080NoneSS135Digital Output Card with cableNo44521.444521.42.0FalseNoneNoneFalseNoneFalse89042.80
284114492080NoneSS136Heavy Duty Relays(HDR)No693.84693.842.0FalseNoneNoneFalseNoneFalse1387.680
284114592080NoneSS137MAINTENANCE TOOLS AND PLANTS : Earth resistance testerNos33185.1433185.141.0FalseNoneNoneFalseNoneFalse33185.140
284114692080NoneSS138Portable (mobile) oil pumps (1/2 HP Air pump 500 to 1000 gallons)Nos23891.4623891.461.0FalseNoneNoneFalseNoneFalse23891.460
284114792080NoneSS139Telescopic ladder Aluminium 6 Mtr. HeightNos26693.9626693.961.0FalseNoneNoneFalseNoneFalse26693.960
284114892080NoneSS140Ring spanner setSet1038.41038.41.0FalseNoneNoneFalseNoneFalse1038.40
284114992080NoneSS141Tube spanner setSet1693.31693.31.0FalseNoneNoneFalseNoneFalse1693.30
284115092080NoneSS142Pipe wrench 24 inchNos.1475.01475.02.0FalseNoneNoneFalseNoneFalse2950.00
284115192080NoneSS143Pipe wrench 18 inch.Nos.816.56816.562.0FalseNoneNoneFalseNoneFalse1633.120
284115292080NoneSS144Hydraulic crimpping tools up to 1000 Sq.mmNos73175.3473175.341.0FalseNoneNoneFalseNoneFalse73175.340
284115392080NoneSS145Hydraulic shearing machineNos2784.82784.81.0FalseNoneNoneFalseNoneFalse2784.80
284115492080NoneSS146Threading die set for pipe threadingNos2784.82784.81.0FalseNoneNoneFalseNoneFalse2784.80
284115592080NoneSS147Welding machine (arc welding) 10kVANos32911.3832911.381.0FalseNoneNoneFalseNoneFalse32911.380
284115692080NoneSS148Portable drilling machine with stand (heavy duty)Nos50437.9250437.921.0FalseNoneNoneFalseNoneFalse50437.920
284115792080NoneSS149Rubber hand gloves (15 kV tested)Pairs345.74345.743.0FalseNoneNoneFalseNoneFalse1037.220
284115892080NoneSS150Rechargeable 5 W LED Hand TorchNos1509.221509.222.0FalseNoneNoneFalseNoneFalse3018.440
284115992080NoneSS151Hand torch 3 CellsNos441.32441.322.0FalseNoneNoneFalseNoneFalse882.640
284116092080NoneSS152Insulated cutting plier 12 inch sizeNos463.74463.743.0FalseNoneNoneFalseNoneFalse1391.220
284116192080NoneSS153Insulated cutting plier 8 inch sizeNos278.48278.483.0FalseNoneNoneFalseNoneFalse835.440
284116292080NoneSS154Line live testerNos366.98366.982.0FalseNoneNoneFalseNoneFalse733.960
284116392080NoneSS155Screw driver 18"Nos263.14263.143.0FalseNoneNoneFalseNoneFalse789.420
284116492080NoneSS156Screw driver 12"Nos88.588.53.0FalseNoneNoneFalseNoneFalse265.50
284116592080NoneSS157Hammer 8 lbsNos586.46586.462.0FalseNoneNoneFalseNoneFalse1172.920
284116692080NoneSS158Hammer 2 lbsNos293.82293.822.0FalseNoneNoneFalseNoneFalse587.640
284116792080NoneSS159Chain pulley block 5 tonNos49366.4849366.481.0FalseNoneNoneFalseNoneFalse49366.480
284116892080NoneSS160Hydraulic jack 5 TonNos8316.648316.644.0FalseNoneNoneFalseNoneFalse33266.560
284116992080NoneSS161Pipe derrickSet32840.5832840.581.0FalseNoneNoneFalseNoneFalse32840.580
284117092080NoneSS162Allen keysSet564.04564.041.0FalseNoneNoneFalseNoneFalse564.040
284117192080NoneSS163Box spanners (12 Nos. per set)Set5271.065271.061.0FalseNoneNoneFalseNoneFalse5271.060
284117292080NoneSS164Transil oil di-electric break down test kit.Nos119811.3119811.31.0FalseNoneNoneFalseNoneFalse119811.30
284117392080NoneSS165Insulation Tester Digital type (megger) 2.5 - 5 kVNos65263.4465263.441.0FalseNoneNoneFalseNoneFalse65263.440
284117492080NoneSS166Insulation megger 500 VNos20775.0820775.081.0FalseNoneNoneFalseNoneFalse20775.080
284117592080NoneSS167SF-6 Gas leak detector / Gas filling.Nos76985.5676985.561.0FalseNoneNoneFalseNoneFalse76985.560
284117692080NoneSS168Multimeter electromechanicalNos4335.324335.321.0FalseNoneNoneFalseNoneFalse4335.320
284117792080NoneSS169Multimeter ElectronicNos9429.389429.381.0FalseNoneNoneFalseNoneFalse9429.380
284117892080NoneSS170HydrometerNos776.44776.442.0FalseNoneNoneFalseNoneFalse1552.880
284117992080NoneSS171Hydrometer syring suitable for vent holesNos1062.01062.02.0FalseNoneNoneFalseNoneFalse2124.00
284118092080NoneSS172Specific gravity correction chartNos1008.01008.02.0FalseNoneNoneFalseNoneFalse2016.00
284118192080NoneSS173Wall mounting type holder for hydrometer & thermometer (teak wood make)Nos3186.03186.02.0FalseNoneNoneFalseNoneFalse6372.00
284118292080NoneSS174Cell testing voltmeter (3-0-3v) Conforming to IS-1248Nos514.48514.481.0FalseNoneNoneFalseNoneFalse514.480
284118392080NoneSS175Rubber appronNos2256.162256.162.0FalseNoneNoneFalseNoneFalse4512.320
284118492080NoneSS176PippetteNos929.84929.841.0FalseNoneNoneFalseNoneFalse929.840
284118592080NoneSS177Protective gogglesNos1062.01062.02.0FalseNoneNoneFalseNoneFalse2124.00
284118692080NoneSS178Acid resisting jars (4 print capacity)Nos1062.01062.02.0FalseNoneNoneFalseNoneFalse2124.00
284118792080NoneSS179Rubber shoes knee heightPairs2522.842522.842.0FalseNoneNoneFalseNoneFalse5045.680
284118892080NoneSS180Glass funnelNos797.68797.682.0FalseNoneNoneFalseNoneFalse1595.360
284118992080NoneSS181Double end spanner: 12 nos /setSet978.22978.222.0FalseNoneNoneFalseNoneFalse1956.440
284119092080NoneSS182Hack saw frame+ B185Nos428.34428.342.0FalseNoneNoneFalseNoneFalse856.680
284119192080NoneSS183Hickery rodsNos6370.826370.824.0FalseNoneNoneFalseNoneFalse25483.280
284119292080NoneSS184Grounding sticks extendable upto 18 ft : 3 nos. of each 6 ft Sticks of 3 phase R, Y, B (3 nos. of 1 set)Set2070.92070.98.0FalseNoneNoneFalseNoneFalse16567.20
284119392080NoneSS185Manila rope 1" (1 bundle of 100 mts)Bundle7470.47470.41.0FalseNoneNoneFalseNoneFalse7470.40
284119492080NoneSS186Manila rope 3/4" (1 bundle of 100 mts)Bundle4404.964404.961.0FalseNoneNoneFalseNoneFalse4404.960
284119592080NoneSS187Files of various sizes( One set of 6 nos)Set10219.9810219.981.0FalseNoneNoneFalseNoneFalse10219.980
284119692080NoneSS188Hand drilling machineNos25220.1425220.141.0FalseNoneNoneFalseNoneFalse25220.140
284119792080NoneSS189Saftey beltsNos1194.161194.162.0FalseNoneNoneFalseNoneFalse2388.320
284119892080NoneSS190Saftey HelmetsNos325.68325.685.0FalseNoneNoneFalseNoneFalse1628.40
284119992080NoneSS191Steel measuring tape 30 metersNos895.62895.621.0FalseNoneNoneFalseNoneFalse895.620
284120092080NoneSS192Steel measuring tape 15 metersNos657.26657.261.0FalseNoneNoneFalseNoneFalse657.260
284120192080NoneSS193MISCELLANEOUS ITEMS : Rubber mats 1000 mm x 2000 mm x 12mm size suitable for 1.1kV class.Nos3540.03540.015.0FalseNoneNoneFalseNoneFalse53100.00
284120292080NoneSS194First aid box completeNos708.0708.01.0FalseNoneNoneFalseNoneFalse708.00
284120392080NoneSS195Shock treatment charts, hard board, liminated with coloured pictures & literature both in Kannada & English.Nos2360.02360.01.0FalseNoneNoneFalseNoneFalse2360.00
284120492080NoneSS196Water filter / Water purifier : Wall mounting type (Aqua-guard type).Nos21240.021240.01.0FalseNoneNoneFalseNoneFalse21240.00
284120592080NoneSS197Sub-station name board duly painted.Nos11800.011800.01.0FalseNoneNoneFalseNoneFalse11800.00
284120692080NoneSS198Fixograph of size 1.5m x 2.5m with English / Kannada alphabets. FixographSet6136.06136.01.0FalseNoneNoneFalseNoneFalse6136.00
284120792080NoneSS199Door locks 7 levers (reputed make make) (Sizes and capacities to be got approved)Nos590.0590.05.0FalseNoneNoneFalseNoneFalse2950.00
284120892080NoneSS200Danger board ( prohibited ) with support structure including fixing in front of the gateNos2360.02360.01.0FalseNoneNoneFalseNoneFalse2360.00
284120992080NoneSS201Equipments name plates and earthing name plates including fixing at outdoor yardNos375.24375.24120.0FalseNoneNoneFalseNoneFalse45028.80
284121092080NoneSS202Furniture for control room, staff and maintenance, staff of reputed make: Steel Almirahs 6 1/2 feetNo.11800.011800.02.0FalseNoneNoneFalseNoneFalse23600.00
284121192080NoneSS203Steel Almirahs 6 1/2 feet with glass panel doors.No.9440.09440.01.0FalseNoneNoneFalseNoneFalse9440.00
284121292080NoneSS204Officer's tablesNo.10620.010620.04.0FalseNoneNoneFalseNoneFalse42480.00
284121392080NoneSS205Steel slotted angle rack (big size)No.2950.02950.04.0FalseNoneNoneFalseNoneFalse11800.00
284121492080NoneSS206Steel slotted angle rack (small size)No.2360.02360.04.0FalseNoneNoneFalseNoneFalse9440.00
284121592080NoneSS207Steel dust binsNo.472.0472.04.0FalseNoneNoneFalseNoneFalse1888.00
284121692080NoneSS208Executive Revolving chairsNo.9440.09440.08.0FalseNoneNoneFalseNoneFalse75520.00
284121792080NoneSS209S type arm chairsNo.1770.01770.010.0FalseNoneNoneFalseNoneFalse17700.00
284121892080NoneSS210Steel folding chairsNo.590.0590.04.0FalseNoneNoneFalseNoneFalse2360.00
284121992080NoneSS211Earth Mat Formation Supply of Providing CI pipe of 100mm ID 13mm thick 2.75mtr long with 2 part GI flat 75*12 mm clamp welded allround the pipe etc including the cost of excavation (all materisla supplied by contractor)Nos15094.5615094.56119.0FalseNoneNoneFalseNoneFalse1796252.640
17091154350000NoneNoneSub-StationStation Erection Portion38744449.28
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
284122092081NoneSE1STATION ERECTION Portion: Refer Techno commercial sheet for details & split up POWER TRANSFORMERS: a. 150 MVA, 220/66/11 kV Power Transformer : 3 Ph, 50 Hz, Core type, 3 winding Transformer, Star/Star/Delta, Vector Group: YNyn0d11, OLTC, Bushing CT for Tertiary of ratio 1515/1A, 5P20, 15VA, ONAN/ONAF/OFAF with Fan control cubicle, RTCC Panel, Numerical RTCC panel with fibre optic temperature sensor, first filling of oil and 10% spare oil in non-returnable drums, etc., complete with 2x50% separate Radiator Bank on left side and terminal connector suitable for Single Drake ACSR/Double Drake ACSR on primary and secondary side of Transformer and Neutral connectors suitable for copper flats as per technical specification. 150MVA, 220/66/11kV TransformerNo1160036.761160036.762.0FalseNoneNoneFalseNoneFalse2320073.520
284122192081NoneSE2b. POWER TRANSFORMERS: 31.5 MVA, 66/11 kV Transformer : 3 Ph, 50 Hz, Core type, 2 winding Delta/Star, Vector Group: DYn11, OLTC, ONAN/ONAF with Fan control cubicle, RTCC Panel, Numerical RTCC panel with fibre optic temperature sensor, first filling of oil and 10% spare oil in non-returnable drums, etc., complete with Terminal connector suitable for single Drake ACSR on primary side of Transformer and copper flat on 11 kV and neutral side as per technical specification 31.5MVA, 66/11kV TransformerNo423222.34423222.342.0FalseNoneNoneFalseNoneFalse846444.680
284122292081NoneSE3SF-6 CIRCUIT BREAKER: SF6 type with operating mechanism and marshalling box along with associated support structure and terminal connector etc., as per technical specification. a. 220 kV, 2500A, 50kA ClassSet84774.7484774.745.0FalseNoneNoneFalseNoneFalse423873.70
284122392081NoneSE4b. Total 66kV class Circuit BreakersSet60123.3660123.3610.0FalseNoneNoneFalseNoneFalse601233.60
284122492081NoneSE5ISOLATORS: Isolators and Terminal Connectors, as per Technical Specification including solid core cylindrical post insulators. (1) 220kV, 1250A, 40kA for three seconds short time current rating, electrically cum manually operated double break type disconnects with solid core insulators, terminal connector suitable for Al. tube/conductor, marshalling box etc., complete as per technical specification a. Total No. of 220kV Upright IsolatorsSet10152.7210152.7220.0FalseNoneNoneFalseNoneFalse203054.40
284122592081NoneSE6b. Under hung mounting type without earth switch( 130000mm Mounting height)No14431.414431.44.0FalseNoneNoneFalseNoneFalse57725.60
284122692081NoneSE72 66 kV double break electrically cum manually operated isolators with solid core insulator, terminal connector suitable for Al.tube / conductor, marshalling box etc., complete as per technical specification a. Total No. of 66kV Upright Isolators (66kV 200A, 40kA-11Nos & 66kV 1250A, 40kA 24NosSet6040.426040.4235.0FalseNoneNoneFalseNoneFalse211414.70
284122792081NoneSE8b. Total No. of Under hung mounting type without Earth switch Isolators ( 8125mm-2Nos & 13125mm-4Nos)Set6256.366256.366.0FalseNoneNoneFalseNoneFalse37538.160
284122892081NoneSE9CURRENT TRANSFORMER :Oil filled Current Transformer 0.2s class with terminal connector suitable for Al.tube/conductor with marshalling box etc., complete as per technical specification. (i) 220 kV Class : 1200-800-400-300/1-1-1 A plus 2 cores of 1200/1 ANos15134.2915134.2917.0FalseNoneNoneFalseNoneFalse257282.930
284122992081NoneSE10Total No. of 66 kV Class Current Transformers ( 1600-1000/1-1-1 A-11Nos, 66 kV Class : 400-200/1-1-1 A-6Nos and 66 kV Class : 1200-800/1-1-1 A -15Nos)Nos7322.37322.332.0FalseNoneNoneFalseNoneFalse234313.60
284123092081NoneSE1111 kV NCT : 2000-1200/1-1-1 A (of similar rating as incomer of 2000A, 25kA 11kV Switchgear) (Required for 31.5MVA, 66/11kV Tr) NOTE: 1. All the current transformers in each kV class shall be of one and the same make for interchangeability and reliability of performance. 2. The make and characteristic of 11kV NCT should be same as that of the incomer CT of 11kV Switchgear. To ensure this the 11kV NCT should be procured from the supplier of 11kV CTs to 11kV Switchgear only.Nos2114.962114.962.0FalseNoneNoneFalseNoneFalse4229.920
284123192081NoneSE12VOLTAGE TRANSFORMER:Single phase, oil filled, outdoor type VT with terminal connector suitable for Al. tube/conductor with marshalling box etc., complete as per technical specification. (i)220kV, VTs of Ratio 220kV/root3/110V/root3-110V/root3/110V/root3, For Metering Core 300VA, Accuracy 0.2 For Protection Core 1 & 2 - 200VA, Accuracy 3PNos9397.929397.926.0FalseNoneNoneFalseNoneFalse56387.520
284123292081NoneSE13ii 66kV VTs of Ratio 66kV/root3/110V/root3-110V/root3-110V/root3 Core-1Metering 300VA, Accuracy 0.2 Core-2Protection 200VA, Accuracy 3P Core-3Protection Open Delta, 50VA, Accuracy-3PNos7360.067360.066.0FalseNoneNoneFalseNoneFalse44160.360
284123392081NoneSE14SURGE ARRESTOR :with Terminal Connector suitable for Drake ACSR : 198 kV Metal Oxide with surge counter Arrestor class : Station Medium Duty (SM) - Discharge Class 3 - for Overhead Line, Transformer & UG CableNos668.67668.6712.0FalseNoneNoneFalseNoneFalse8024.040
284123492081NoneSE1560 kV Metal Oxide with surge counter Arrestor class : Discharge Class 3 (Station Medium Duty (SM)) - for Transformer & UG Cable Remarks: All the Surge Arresters are with Surge Monitors & Insulating BaseNos288.32288.3227.0FalseNoneNoneFalseNoneFalse7784.640
284123592081NoneSE16C&R Panel compatible to IEC 61850, communication protocol for Sub-station Automation System in 220 kV & 66 kV Sub-station complete as per technical specification 220 kV class Panel for lines, transformers & Bus couplerNos93785.2293785.225.0FalseNoneNoneFalseNoneFalse468926.10
284123692081NoneSE17220kV Bus Bar Protection type 2BBA panelNos44034.0644034.061.0FalseNoneNoneFalseNoneFalse44034.060
284123792081NoneSE18Erection of C&R Panel 66 kV Panel for UG Cable/OH Line, Transformers & Bus Coupler - Type 6L (As per Annexure RPP4-Cable-SAS)Nos65891.265891.27.0FalseNoneNoneFalseNoneFalse461238.40
284123892081NoneSE19Erection of Simplex type C&R Panel 66 kV Panel for UG Cable/OH Line, Transformers & Bus Coupler - Type 6L (As per Annexure RPP4-Cable-Without SAS)Nos55653.5255653.521.0FalseNoneNoneFalseNoneFalse55653.520
284123992081NoneSE2011 kV Panel for Overhead Line - Type 1L Provision for 2 feeders to be made in one panel (As per Annexure RPP7-SAS): provision for 2 capacitor feeder to be made in one panel, provision for 1 line feeder & 1 Bus Coupler to be made in one panel)Set65891.265891.211.0FalseNoneNoneFalseNoneFalse724803.20
284124092081NoneSE21Total Weight of Station Structure and Mounting Structures including Bolt & NutsMT6753.146753.14196.8825FalseNoneNoneFalseNoneFalse1329575.086050
284124192081NoneSE22Formation of Main / Cross Bus with Drake Conductor Double Drake ACSR-220 kV SidePer Bay23112.6623112.668.0FalseNoneNoneFalseNoneFalse184901.280
284124292081NoneSE23Single Drake ACSR-66 kV SidePer Bay14262.6614262.668.0FalseNoneNoneFalseNoneFalse114101.280
284124392081NoneSE24Post Insulators: for 220kV sideStack667.88667.8860.0FalseNoneNoneFalseNoneFalse40072.80
284124492081NoneSE25Post Insulators for 66kV sideStack287.92287.92166.0FalseNoneNoneFalseNoneFalse47794.720
284124592081NoneSE26a) Auxiliary Transformers: 250 kVA, 11 kV/433 V, 3 phase Delta Star, Dyn11 : Supply of Auxiliary Transformer with copper windings & oil, cable termination type on both HT & LT outdoor type with off load tap changer in steps of 2.5 %No24639.5824639.582.0FalseNoneNoneFalseNoneFalse49279.160
284124692081NoneSE27LTAC Panel (Indoor), 415 V as per technical specification comprising of voltmeter and ammeter, 2 I/C ACB, 800A + 2 O/G SFU, 200A + 8 O/G SFU, 100A + 14 O/G SFU, 63A + 12 O/G, 32A + 1B/C SFU, 800A + 1DG change over switch 300A etc., complete as per technical specification.No6678.86678.81.0FalseNoneNoneFalseNoneFalse6678.80
284124792081NoneSE28Power Cable : a. from Auxiliary Transformers to LTAC Panel 1.1kV PVC Insulated 4x240Sq.mm Al. Cable 3and half core with Glands / Lugs / Ferrules -0.1Kms b. PVC insulated aluminium power cable (AC Supply for lighting etc.,) 70 Sq.mm 3.5 Core, with glands / lugs / ferrules -2.0KmsKm17700.017700.02.1FalseNoneNoneFalseNoneFalse37170.00
284124892081NoneSE29AC Distribution box a. Double front type, 24 terminals, 1200 x1350 x600 mm, Two I/C of 100 A MCCB 20 KA + 24 O/G 16 A MCB +2 O/G of 100 A HRC Fuse -5.00Nos b. Single front type, 6 terminals 750 x1350 x300 mm, one I/C of 100 A, MCCB 20 KA+ 6 O/G 16 A MCB +1 O/G of 100 A HRC Fuse ( for 220kV Station) -4.00Nos c. single front type, 6 terminal 1200x1350x300mm, 1 IC of 100Amps MCCB 20kA+6 OG MCB 16Amps+1 OG of 100A, HRC fuse.( For 66kV Stations) -1.00No.Nos2909.882909.8810.0FalseNoneNoneFalseNoneFalse29098.80
284124992081NoneSE30A) STATION BATTERY : 220 V, 300 AH, Battery set consisting of 110 No. cells per bank as per technical specifications Installing, assembling, filling of acid, wiring, assisting, test charging & discharging Battery setSet35974.6635974.662.0FalseNoneNoneFalseNoneFalse71949.320
284125092081NoneSE31Battery charger suitable for '2 X 220 V, 300 AH, with float (2 Nos) & 2 Nos of boost battery charger including control panels, change over arrangements etc., complete along with two separate DC distribution panel (indoor) 1I/C+20 O/G SFU 60 A+20 O/G SFU 30 A as per technical specifications.Set57548.657548.61.0FalseNoneNoneFalseNoneFalse57548.60
284125192081NoneSE32Laying of control cable from equipment to control panels-TotalKms17700.017700.067.26FalseNoneNoneFalseNoneFalse1190502.00
284125292081NoneSE3311kV Switchgear 11kV Switchgear: 500MVA, 31.5kA, 2000A for incomer and 1250A for feeders (2IC+1BC+16F+4CB+1AP). Annuciator panel shall be simplex panel instead of desk type mentioned else where in specification.Set298549.84298549.841.0FalseNoneNoneFalseNoneFalse298549.840
284125392081NoneSE34Laying of 11kV XLPE Aluminium Cable-3 Core -TotalKm84.9684.961800.0FalseNoneNoneFalseNoneFalse152928.00
284125492081NoneSE35Fixing of pot head for HT cables Heat shrinkable type Cable Termination for 1x1000Sq.mm XLPE CableNos4427.364427.3648.0FalseNoneNoneFalseNoneFalse212513.280
284125592081NoneSE36Making & Fixing of pot head for HT cables Heat shrinkable type Cable Termination suitable for 3x400Sq.mm Cable & 3x95 Sq.mm cablesNos3136.443136.4412.0FalseNoneNoneFalseNoneFalse37637.280
284125692081NoneSE37Testing & commissioning of 12.1kV, 5.8 MVAR Capacitor bankSet26229.0426229.044.0FalseNoneNoneFalseNoneFalse104916.160
284125792081NoneSE3811kV Isolator structure for Capacitor Bank: 11 kV Double Break Isolator, 400A, 25kASet1432.521432.5220.0FalseNoneNoneFalseNoneFalse28650.40
284125892081NoneSE39Supplying & Erection of Double pole structure with 9Mts. RCC poles,145Kg WL and with provision for fixing 11 kV 400 A Roaster single break isolators & provision for fixing 9kV lightning arrestors etc., complete set with wiring materials.Set4878.124878.1216.0FalseNoneNoneFalseNoneFalse78049.920
284125992081NoneSE40Erection , Installation & commissioning of CCTV Surveillance system i) PTZ Camera: 5NosNos.1427.81427.85.0FalseNoneNoneFalseNoneFalse7139.00
284126092081NoneSE41ii) Fixed Camera:Nos1427.81427.88.0FalseNoneNoneFalseNoneFalse11422.40
284126192081NoneSE42iii) HMINos95859.6695859.661.0FalseNoneNoneFalseNoneFalse95859.660
284126292081NoneSE43iv) OFC 6F FibreSet71390.071390.01.0FalseNoneNoneFalseNoneFalse71390.00
284126392081NoneSE44Establishing SCADA Communication Equipments a) Installation, testing, integration & commissioning of SDH Equipment (5 MSP & 3 MSP)Nos50686.950686.91.0FalseNoneNoneFalseNoneFalse50686.90
284126492081NoneSE45Installation of Cabinet Equipment to house SDH Equipment + Optical cards + Triibutary Cards, Drop/Insert MUX Equipments and DACS EquipmentNos1427.81427.81.0FalseNoneNoneFalseNoneFalse1427.80
284126592081NoneSE4648V, 200 AH Float cum boost Charger, 75 ANos6508.886508.881.0FalseNoneNoneFalseNoneFalse6508.880
284126692081NoneSE4748V, 200AH Battery SetSet37354.0837354.081.0FalseNoneNoneFalseNoneFalse37354.080
284126792081NoneSE48Materials for new bay integration to existing SCADA panel: 1. labour cost for Multi Functional Transducer (MFT) 0.2S classNo1834.91834.91.0FalseNoneNoneFalseNoneFalse1834.90
284126892081NoneSE492.Labour cost for Opto Coupler (220 or 110V DC)No1834.91834.91.0FalseNoneNoneFalseNoneFalse1834.90
284126992081NoneSE50Cables : Total c) Current Cable-Copper core with 4.0sqmm cross section mutlistrand 4 core for CT Termination (4 core-2 runs)-5Mtrs d) Voltage Cables-Copper core with 2.5sqmm cross section mutlistrand 4 core for PT Termination-5Mtr f) 10C X 1.5 Sq mm multistrand, conforming to KPTCL specification -500MtrMtr17.717.7510.0FalseNoneNoneFalseNoneFalse9027.00
284127092081NoneSE51e) Signal/communication Cables-Armoured copper 10C x 0.5 Sq mm mutlistrand 10coreMtr29.529.5500.0FalseNoneNoneFalseNoneFalse14750.00
284127192081NoneSE52Earth Mat Formation 1. laying of MS flat 75*12mm flat welding and applying ACB paint to the welded portion and covering witht sodium Bentonite clay as per drawing /standard (all materials to be supplied by contractor)Rmtr990.02990.0216927.0FalseNoneNoneFalseNoneFalse16758068.540
284127292081NoneSE532. Grounding of equipments with 75*12mm GI flat and connecting equipments to the earthmat/ground pit including all connected works.Rmtr1080.881080.888711.0FalseNoneNoneFalseNoneFalse9415545.680
284127392081NoneSE543. Providing 25mm dia 1.05mtr long earthmat spike of MS rod including bending top 50mm etc and connecting to earthmat as per specidication.Nos534.54534.54244.0FalseNoneNoneFalseNoneFalse130427.760
284127492081NoneSE554.Erection charges of Providing CI pipe of 100mm ID 13mm thick 2.75mtr long with 2 part GI flat 75*12 mm clamp welded allround the pipe etc including the cost of excavation (all materisla supplied by contractor)Nos4119.384119.38119.0FalseNoneNoneFalseNoneFalse490206.220
284127592081NoneSE565. Supplying and fixing 450mm dia x 450mm dia height 1.5 in to 2 in hume pipe collars for earth pits.Nos1768.821768.82119.0FalseNoneNoneFalseNoneFalse210489.580
284127692081NoneSE576. Deep bore electrode of 40mm dia, 5mtr Long: Sinking bore of 150mm clear dia using fast rig including fixing of 40mm dia MS rod, including jointing the pipes as per KPTCL standard and providing sodium bentonite treatment in the annular space, including transportation of rig and other supporting vehicles etc., complete as per the directions of engineer in charge, including cost of MS rod and sodium bentonite. a) Drilling 40mm dia bore (5mtr x 22Nos)Rmtr1000.641000.64110.0FalseNoneNoneFalseNoneFalse110070.40
284127792081NoneSE58b)40 mm dia MS Rods deep Electrode of 40mm Dia 10mt long each(22NOs x 5mtr=110Rmtr)Rmtr1109.21109.2110.0FalseNoneNoneFalseNoneFalse122012.00
284127892081NoneSE59c) Bentonite clayKgs29.529.51100.0FalseNoneNoneFalseNoneFalse32450.00
284127992081NoneSE60d)GI flats for joining two rods by welding to obtain continuos length(Including Material labour etc,. Complete) Note : All the MS flat conductors, CI pipe electrodes & deep bore electrodes shall be treated with Sodium BentonitePer Joint1174.11174.122.0FalseNoneNoneFalseNoneFalse25830.20
17091154350000NoneNoneSub-StationStation Mandatory Supply Portion13899333.03
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
284128092082NoneSM1Mandatory Spares for 220kV Station Power Transformer (150 MVA, 220/66/ 11kV) Oil collecting bottleNo8904.08904.06.0FalseNoneNoneFalseNoneFalse53424.00
284128192082NoneSM2Terminal Connector clamps a) Suitable for 245 kV class bushing to suit single Drake ACSR.No1314.521314.526.0FalseNoneNoneFalseNoneFalse7887.120
284128292082NoneSM3b) Suitable for 66 kV class bushing to suit Double Drake ACSR.No2178.282178.286.0FalseNoneNoneFalseNoneFalse13069.680
284128392082NoneSM4Valves a) Drain valve (100mm to 200 mm size) suitable for 220kV classNo5246.285246.281.0FalseNoneNoneFalseNoneFalse5246.280
284128492082NoneSM5b) Top/Bottom Filter Valve (50mm to 100 mm size) suitable for 220kV class TransformerNo7868.247868.242.0FalseNoneNoneFalseNoneFalse15736.480
284128592082NoneSM6c) Top/Middle/Bottom Oil Sampling Valve with Plug (15-25mm mm size) suitable for 220kV and above class TransformerNo5246.285246.283.0FalseNoneNoneFalseNoneFalse15738.840
284128692082NoneSM7d) Header Pipe valveNo3846.83846.81.0FalseNoneNoneFalseNoneFalse3846.80
284128792082NoneSM8e) Gate/ Butterfly valves of various sizes ranging from 50 mm to 200mm suitable for 220kV class TransformersSet9836.489836.481.0FalseNoneNoneFalseNoneFalse9836.480
284128892082NoneSM9MOGNo8743.88743.81.0FalseNoneNoneFalseNoneFalse8743.80
284128992082NoneSM10Prismatic GaugeNo17486.4217486.422.0FalseNoneNoneFalseNoneFalse34972.840
284129092082NoneSM11Starters, contactors, relaysSet71673.7871673.781.0FalseNoneNoneFalseNoneFalse71673.780
284129192082NoneSM12Pressure Relief Device (PRD or PRV)No12764.0612764.061.0FalseNoneNoneFalseNoneFalse12764.060
284129292082NoneSM13Oil surge relayNo4416.744416.741.0FalseNoneNoneFalseNoneFalse4416.740
284129392082NoneSM14Bucholtz relayNo10316.7410316.741.0FalseNoneNoneFalseNoneFalse10316.740
284129492082NoneSM15Tap position IndicatorNo3496.343496.341.0FalseNoneNoneFalseNoneFalse3496.340
284129592082NoneSM16Fixed and moving contacts for diverter switchSet398687.78398687.781.0FalseNoneNoneFalseNoneFalse398687.780
284129692082NoneSM17Fixed and moving contacts for selector switch 220kV and above classSet612018.8612018.81.0FalseNoneNoneFalseNoneFalse612018.80
284129792082NoneSM18WTI with 4 contacts, 15 meters capillary length with built in CCU RTD and external remote indicator, range 0-150 deg C with SCADA/SAS compatibilitySet69944.569944.51.0FalseNoneNoneFalseNoneFalse69944.50
284129892082NoneSM19OTI with 2 contacts, 15 meters capillary length with built in CCU, RTD and external remote indicator range 0-150 deg C with SCADA/SAS compatibilitySet21858.3221858.321.0FalseNoneNoneFalseNoneFalse21858.320
284129992082NoneSM20PT 100 Sensor along with probe of suitable lengthSet88481.1288481.121.0FalseNoneNoneFalseNoneFalse88481.120
284130092082NoneSM21Circuit Breaker (CB) 1) Closing coil with resistor (For one Complete Circuit Breaker): a) for 220kV CBNo3348.473348.471.0FalseNoneNoneFalseNoneFalse3348.470
284130192082NoneSM22b) for 66 kV CBNo1614.221614.221.0FalseNoneNoneFalseNoneFalse1614.220
284130292082NoneSM232) Tripping coil with resistor (For one Complete Circuit Breaker): a) for 220kV CBNo4503.964503.961.0FalseNoneNoneFalseNoneFalse4503.960
284130392082NoneSM24b) for 66kV CBNo2446.912446.911.0FalseNoneNoneFalseNoneFalse2446.910
284130492082NoneSM253) Terminal Pad (For one Complete Circuit Breaker): a) for 220kV CBSet10257.7410257.741.0FalseNoneNoneFalseNoneFalse10257.740
284130592082NoneSM26b) for 66kV CBSet7466.057466.051.0FalseNoneNoneFalseNoneFalse7466.050
284130692082NoneSM274) Terminal connector (For one Complete Circuit Breaker): a) for 220kV CBSet4475.724475.721.0FalseNoneNoneFalseNoneFalse4475.720
284130792082NoneSM28b) for 66kV CBSet4108.624108.621.0FalseNoneNoneFalseNoneFalse4108.620
284130892082NoneSM29SF6 gas cylinders filled with SF6 gas suitable for 1 no of CB(220kV CB & 66V CB)Set51767.3551767.351.0FalseNoneNoneFalseNoneFalse51767.350
284130992082NoneSM30Isolator : 1) Copper Contact fingers male & female (For one Isolator) a) for 220KV ClassSet42027.5142027.511.0FalseNoneNoneFalseNoneFalse42027.510
284131092082NoneSM31b) for 66kV CBSet30804.7430804.741.0FalseNoneNoneFalseNoneFalse30804.740
284131192082NoneSM322) Terminal Pad (For one Complete Circuit Breaker): a) for 220kV CBSet3620.963620.961.0FalseNoneNoneFalseNoneFalse3620.960
284131292082NoneSM33b) for 66kV CBSet3620.963620.961.0FalseNoneNoneFalseNoneFalse3620.960
284131392082NoneSM343) Terminal connector (For one Complete Circuit Breaker): a) for 220KV CBSet2950.032950.031.0FalseNoneNoneFalseNoneFalse2950.030
284131492082NoneSM35b) for 66kV CBSet2950.032950.031.0FalseNoneNoneFalseNoneFalse2950.030
284131592082NoneSM36Relay Panel Spares 1) All Type of Numerical Relays (1No. each type)Set868810.61868810.611.0FalseNoneNoneFalseNoneFalse868810.610
284131692082NoneSM372) Tripcircuit supervision relay(2Nos)Set19028.6819028.681.0FalseNoneNoneFalseNoneFalse19028.680
284131792082NoneSM383) Self reset trip relay [1No. each type]Set10361.2910361.291.0FalseNoneNoneFalseNoneFalse10361.290
284131892082NoneSM394) Hand reset trip relay[1No. each type]Set10192.8810192.881.0FalseNoneNoneFalseNoneFalse10192.880
284131992082NoneSM405) Timer relay [1No. each type]Set8689.158689.151.0FalseNoneNoneFalseNoneFalse8689.150
284132092082NoneSM416) DC supervision relaysSet12519.0612519.061.0FalseNoneNoneFalseNoneFalse12519.060
284132192082NoneSM427) Flag relays [1No. each type]Set8618.18618.11.0FalseNoneNoneFalseNoneFalse8618.10
284132292082NoneSM438) Auxillary relays [1No. each type]Set20026.2820026.281.0FalseNoneNoneFalseNoneFalse20026.280
284132392082NoneSM44Mandatory Spares for SAS : 1) Bay Control Unit with configuration softwareSet190013.48190013.482.0FalseNoneNoneFalseNoneFalse380026.960
284132492082NoneSM452) Ethernet Switch of each typeNo.276480.25276480.251.0FalseNoneNoneFalseNoneFalse276480.250
284132592082NoneSM463) Optical Cable fibre of longest lengthNo.55579.0655579.061.0FalseNoneNoneFalseNoneFalse55579.060
284132692082NoneSM47Maintenance and Testing equipment: 1) Fully automatic and Tan delta Capacitance test kitSet1102665.01102665.01.0FalseNoneNoneFalseNoneFalse1102665.00
284132792082NoneSM482) Poratable dissolved gas analyserNo4447307.94447307.91.0FalseNoneNoneFalseNoneFalse4447307.90
284132892082NoneSM493) Moisture measuring kit-KARL FISCHER Type moisture kitNo55171.7255171.721.0FalseNoneNoneFalseNoneFalse55171.720
284132992082NoneSM504) SF6 gas filling adaptor kit for Circuit BreakerNo828155.94828155.941.0FalseNoneNoneFalseNoneFalse828155.940
284133092082NoneSM515) Measuring & analysing equipment for moisture & air contentSet566985.14566985.141.0FalseNoneNoneFalseNoneFalse566985.140
284133192082NoneSM526) Micro Ohm meter(1.0 micro-ohm to 199.99 micro ohm)Set184347.19184347.191.0FalseNoneNoneFalseNoneFalse184347.190
284133292082NoneSM537) BDV test kit (Digital)Set496393.41496393.411.0FalseNoneNoneFalseNoneFalse496393.410
284133392082NoneSM548) Circuit Breaker operational analyzer-DCRMSet1180561.611180561.611.0FalseNoneNoneFalseNoneFalse1180561.610
284133492082NoneSM559) Numerical Relay testing kitSet614684.27614684.271.0FalseNoneNoneFalseNoneFalse614684.270
284133592082NoneSM5610) Online DC earth fault locator with built-in charger & rechargeable batteriesSet186270.08186270.081.0FalseNoneNoneFalseNoneFalse186270.080
284133692082NoneSM5711) Combined CT & VT analyzerSet928334.68928334.681.0FalseNoneNoneFalseNoneFalse928334.680
17091154350001NoneNoneSub-StationUG Cable Supply portion1165594871.62
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
284133792083NoneUGS1UG Cable supply portion : (For details & split up refer technocommercial sheet & technical specification) 220 kV single core 1200 sq mm Cable:- 127/220 kV (Earthed), Single core 1200 sq.mm, stranded, annealed copper conductor, segmental, compacted, circular (Milken), conductor screen, cross linked, Polyethyline (XLPE) insulation, core screen, semi conducting water swellable layer, lead alloy 'E' sheathed, semi conducting bedding tapes, helically applied plain round copper wire screen, plain copper tape within open helix, water swellable tape with overall extruded high density polyehtylene sheath coated with graphite etc., as per technical specifications.Km34489040.034489040.024.486FalseNoneNoneFalseNoneFalse844498633.440
284133892083NoneUGS266 kV, 1 core,1000sqmm cable:66 kV (E) grade, 1 core, Circular, stranded, plain annealed Segmental compact type miliken copper condutor, conductor screen on extruded semi conducting compound, cross linked polyethylene (XLPE) insulation, core screen, semiconducting water swellable layer, extruded lead alloy (E) sheath, semi conducting bedding tapes, helically applied plain round copper wire screen, plain copper tape in open helix, water swellable tape with overall extruded high density polyethylene sheath, coated with graphite etc., as per technical specification.Km18046920.018046920.011.682FalseNoneNoneFalseNoneFalse210824119.440
284133992083NoneUGS3Joints : Joints suitable for 220 kV single core 1200 sq. mm copper conductor, XLPE insulated, lead sheathed cable complete with all accessories as per specification. a.Insulated joints/sheath sectionalizing joints - 24nos/phase b.Normal straight through joints- 6 nos c.earthing joints:-12nos.Set892375.0892375.042.0FalseNoneNoneFalseNoneFalse37479750.00
284134092083NoneUGS4Joints : Joints suitable for 66kV single core 1000sqmm copper conductor, XLPE insulated, Lead sheathed cable. Joints are of Insulated joints, Normal straight through joints & Earthing Joints a.Insulated/sheath sectionalizing joints- 6 b.Normal straight through joints-12 c. earthing joints- 3Set199892.0199892.021.0FalseNoneNoneFalseNoneFalse4197732.00
284134192083NoneUGS5Terminations: Out door type Cable end termination suitable for 220 kV single core 1200 sq.mm copper conductor, XLPE insulated, Lead sheathed cable including PVC earthing cable.Nos1300725.81300725.812.0FalseNoneNoneFalseNoneFalse15608709.60
284134292083NoneUGS6Terminations:Outdoor cable end termination suitable for 66KV, single core, 1000sqmm copper conductor, XLPE insulated, lead sheathed cable including PVC earthing cable.Nos324110.6324110.66.0FalseNoneNoneFalseNoneFalse1944663.60
284134392083NoneUGS7220 kV Single phase Link boxes : Single phase Link box outdoor structure mounting type, with SVL suitable for 220 kV, 1200/ 1000 Sq mm UG cable including 400 Sq mm sheath bonding cable as per the technical specification. NOTE: The size of the earthing cable specified is indicative only. The same shall be suitable for short circuit fault current of 31.5kANos92807.092807.012.0FalseNoneNoneFalseNoneFalse1113684.00
284134492083NoneUGS866kV Single phase Link Boxes:Single phase outdoor structure mounting type with SVL/CCPU and PVC earthing cable including the cost of 240 Sq.mm PVC earthing cable, as per technical specifications. NOTE: The size of the earthing cable specified is indicative only. The same shall be suitable for short circuit fault current of 31.5kANos51400.851400.86.0FalseNoneNoneFalseNoneFalse308404.80
284134592083NoneUGS9220 kV Three phase Link boxes : Three phase cross bonding Link box with SVL including 400 Sq mm sheath bonding cable and 400/400 Sq mm co-axial cable as per technical specification suitable for 220 kV, 1200/1000 Sq mm UG Cable. The Link box shall be burried type, water proof (capable of immerssion in water), weather proof, rust & dust proof (IP: 68) a) Three phase Cross bonding link box with SVL:-08Nos124218.6124218.68.0FalseNoneNoneFalseNoneFalse993748.80
284134692083NoneUGS10220 kV Three phase Link boxes : Three phase Link box without SVL including 400 Sq mm sheath bonding cable and 400/400 Sq mm co-axial cable as per technical specification suitable for 220 kV, 1200/1000 Sq mm UG Cable. The Link box shall be burried type, water proof (capable of immerssion in water), weather proof, rust & dust proof (IP: 68). b) Three phase link box without SVL :-06 NOTE: The size of the earthing cable specified is indicative only. The same shall be suitable for short circuit fault current of 31.5kANos77101.277101.26.0FalseNoneNoneFalseNoneFalse462607.20
284134792083NoneUGS1166kV Three phase Link boxes:-Three phase burried type including the cost of 240 sq mm PVC earthing cable & 240/240 sq mm co-axial cable as per technical specifications. The link box shall be water proof (capable of immersion in water) , weather proof, rust & dust proof as per technical specifications). a) Three phase cross bonding Link box with SVL for one circuit - 2 nos. NOTE: The size of the earthing cable specified is indicative only. The same shall be suitable for short circuit fault current of 31.5kANos124218.6124218.62.0FalseNoneNoneFalseNoneFalse248437.20
284134892083NoneUGS12b) 66kV Three phase link box without SVL for one circuit - 1 no.Nos77101.277101.21.0FalseNoneNoneFalseNoneFalse77101.20
284134992083NoneUGS13Surge arrestors: 198 kV Metal Oxide with surge counter Arrestor class : Station Medium Duty (SM) -Discharge Class 3,- for Overhead Line, Transformer & UG Cable. with terminal connector suitable for Al. tube/ conductor), (6 nos for 220 kV CTT).Nos69962.269962.26.0FalseNoneNoneFalseNoneFalse419773.20
284135092083NoneUGS14Terminal Connector suitable for 220 kV UG Cable termination to Moose ACSR at CTT havy type with bolts & nuts and washers, complete. To connect cable end in 220kV Banashankari 6th stage s/s & suitable for termination to the AAAC moose c.Nos1925.761925.7612.0FalseNoneNoneFalseNoneFalse23109.120
284135192083NoneUGS15Terminal connectors to connect 66kV UG cable end termination to the Single Drake ACSR conductor with bolts & nuts and washers, complete.Nos1314.521314.526.0FalseNoneNoneFalseNoneFalse7887.120
284135292083NoneUGS16Fibre optic cable & accessories: 48 Fibre Dual Window Mono Mode (DWMM) Optical Fibre Cable as per technical specification (for LILO of V.Valley-Somanahally line).Kms128620.0128620.07.33FalseNoneNoneFalseNoneFalse942784.60
284135392083NoneUGS17Polyvinyl Lubricated Bond (PLB) HDPE) pipe OD 40 mm with accessoriesKms115640.0115640.07.33FalseNoneNoneFalseNoneFalse847641.20
284135492083NoneUGS18Joint boxNos9349.149349.144.0FalseNoneNoneFalseNoneFalse37396.560
284135592083NoneUGS19UG -OFC to OPGW Joint Box suitable for 48F Straight Joint Kit for Optical Fibre Cable : 48FNos9994.69994.61.0FalseNoneNoneFalseNoneFalse9994.60
284135692083NoneUGS20OFC end termination: Line Interface Unit for Optical Fibre Cable : 48F.Nos24272.624272.66.0FalseNoneNoneFalseNoneFalse145635.60
284135792083NoneUGS21Media converter.Nos5711.25711.24.0FalseNoneNoneFalseNoneFalse22844.80
284135892083NoneUGS22Total weight of HT Cable portion : 55.94MTMT175619.4175619.455.9391FalseNoneNoneFalseNoneFalse9823991.178540
284135992083NoneUGS23Total weight of MS Cable portion : 14.37MT Station portion : 187.15MTMT159913.6159913.6201.5144FalseNoneNoneFalseNoneFalse32224893.155840
284136092083NoneUGS24Total weight of Bolt & Nuts) Cable portion : 2.39MT Station portion : 9.74MTMT168480.4168480.412.1307FalseNoneNoneFalseNoneFalse2043785.188280
284136192083NoneUGS25Tower Acessories Number PlatesNos375.24375.242.0FalseNoneNoneFalseNoneFalse750.480
284136292083NoneUGS26Danger BoardsNos375.24375.242.0FalseNoneNoneFalseNoneFalse750.480
284136392083NoneUGS27Circuit plateNos375.24375.248.0FalseNoneNoneFalseNoneFalse3001.920
284136492083NoneUGS28Phase plate (Set of 3 No.)Set311.52311.528.0FalseNoneNoneFalseNoneFalse2492.160
284136592083NoneUGS29Earth bond 450 mm longNos634.84634.842.0FalseNoneNoneFalseNoneFalse1269.680
284136692083NoneUGS30INSULATOR STRINGS WITH CLAMPS, ARCING HORNS AND HARDWARE for AAAC Moose ACSR Conductor: Single Tension String of 16 units, 120kN disc insulators along with Hardware for AAAC Moose ACSR and arcing hornSet15141.7615141.7624.0FalseNoneNoneFalseNoneFalse363402.240
284136792083NoneUGS31Insulator Hardware: Single Tension string fittings Clamps,Arcing Horns and HardwaresSet4879.34879.324.0FalseNoneNoneFalseNoneFalse117103.20
284136892083NoneUGS32Conductor & Earth wire AAAC Moose ACSRKm651360.0651360.00.365FalseNoneNoneFalseNoneFalse237746.40
284136992083NoneUGS337/3.65mm ground conductor,Km142780.0142780.00.061FalseNoneNoneFalseNoneFalse8709.580
284137092083NoneUGS34Accessories for AAAC Moose ACSR Conductor: i. C-type wedge connector suitable for Moose-MooseNos5242.745242.7424.0FalseNoneNoneFalseNoneFalse125825.760
284137192083NoneUGS35ii. Vibration Dampers suitable for AAAC MooseNos2001.282001.2824.0FalseNoneNoneFalseNoneFalse48030.720
284137292083NoneUGS36Hardware for Earthwire : i. P G Clamps suitable for Ground ConductorNos475.54475.542.0FalseNoneNoneFalseNoneFalse951.080
284137392083NoneUGS37ii. Single Tension clamps, suitable for Ground conductorNos1456.121456.122.0FalseNoneNoneFalseNoneFalse2912.240
284137492083NoneUGS38Supply of Grounding equipment by providing cast iron pipe of 100 mm ID 13 mm thickness, 2.75 metre long with 2 part clamp out of G.I. Flat 50 X 6 mm continuously welded alround the pipe using cast iron welding electrodes as per drawing including the cost of excavation (All materials to be supplied by the contractor) Supply and erection of earthing materials including CI pipe with suitable clamps, collor, earth lead cable, salt, charcol etc., and all necessar earth works etc with complete set.Nos15094.5615094.5624.0FalseNoneNoneFalseNoneFalse362269.440
284137592083NoneUGS39Supply of Grounding of tower with GI Pipe including the cost of 40mm dia 2.5 mm thick, class 'C' GI pipe of 3mtrs length aspoer specifications, with 50x60 mm GI flats 3mtr long, salt, charcoal including excavation and fixing charges.Set6164.326164.322.0FalseNoneNoneFalseNoneFalse12328.640
17091154350001NoneNoneSub-StationUG Cable Erection portion33402809.25
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
284137692084NoneUGE1UG Cable Erection portion : (For details & split up refer technocommecial sheet & Technical specification) 220kV and 66kV UG Cable Surveying: Detailed survey along the route alignment by using Modern Survey equipment like DGPS / Total stations / Digital theodolites / GPS including profiling by using computer aided techniques as detailed in the scope of work, includes the following: Drawing the route profile including features like Roads, Railway lines, drains, park, gardens, P&T Lines, Railways crossing etc.Preparation of cable route profile and final cable route alignment, marking lines and grades. Leveling of the profile with reference to Survey of India bench marks (MSL). Line Schedule along the Right of Way. Soil resistivity along the selected route with measurement at a distance not exceeding 2 km. Route marking along the route with GPS Co-ordinates at every 50 m duly marking road/power line/telecommunication/railway line crossings.Making 150 mm dia bore holes for a depth not less than 3 m or refusal strata at every 50 m for soil classification along with GPS Co-ordinates for each bore holes and back filling of bore holes on completion of work. Burgie details and providing GPS, Co-ordinates at every 50 m, turning points including permanent marks, like poles, telephones lines, buildings etc., Submission of detailed consolidated final report for surveying work done appending all the reports including all relevant information collected during survey, calibration certificates of the instruments used for the work, photos/videos taken at site and submitting soft copies of all documents and hard copy of reports in 6 sets. The detailed report shall contain detailed Survey Report/Soil Resistivity Report/ Line Schedule/Land schedule/Geo referenced and superimposed on the line corridor.Km18468.1818468.187.25FalseNoneNoneFalseNoneFalse133894.3050
284137792084NoneUGE2Laying of UG Cable including Testing & Commissioning: Laying of 220kV EHT Single core 1200 Sq.mm.UG Cable Copper cable in trefoil, tapping, fixing pipes for drain and gate crossing as per drawings and specifications in trench pipes, ducts by pulling, drawing etc. including transport, handling of cable drums paving out cables using standard cable installation equipments and as per directions of the engineer incharge. Note: the quoted rated per Km shall include laying one circuit per km each circuits consisting of 3 Nos single core cable including drums material, equipments to site and returning unused items to stores. Note: One circuit consist of 3 Nos of single core cable and the quoted rate per Ckt Km shall also include the charges for transportaion of cable drums, materials, equipment to site , pre commissioning etc, including pre commissioning test.Ckt Kms1390040.01390040.08.162FalseNoneNoneFalseNoneFalse11345506.480
284137892084NoneUGE3Laying of UG Cable including Testing & Commissioning: Laying of 66kV EHT single core, 1000sqmm XLPE Copper cable in trefoil, tapping , fixing pipes for drain and gate crossing as per drawings & specifications in trench pipes, ducts by pulling, drawing etc., including transport, handling of cable drums, paving out cables using standard cable installation equipments and as per directions of the engineer incharge. Note: The quoted rate per km shall include laying one circuit per km each circuits consisting of 3 nos single core cables including transport of cable drums material, equipments to site etc. including pre commissioning testCkt Kms479080.0479080.03.89FalseNoneNoneFalseNoneFalse1863621.20
284137992084NoneUGE4Handling and making Out door type Cable end termination suitable for the above 220kV class single core 1200 sq.mm cable including PVC Earthing cable with all consuambles at site complete.Nos.288415.6288415.612.0FalseNoneNoneFalseNoneFalse3460987.20
284138092084NoneUGE5Handling & making of Outdoor cable end termination for 66 KV single core, 1000sqmm XLPE cable including PVC Earthing cable with all consuambles at site completeNos.69661.369661.36.0FalseNoneNoneFalseNoneFalse417967.80
284138192084NoneUGE6Handling and making of Normal Straight through joints/Insulated joints/sheath sectionalizing joints/earthing joints suitable for 220KV class single core 1200 sq.mm cableNos.288415.6288415.642.0FalseNoneNoneFalseNoneFalse12113455.20
284138292084NoneUGE7Handling & making joints for 66kV single core 1000sqmm copper XLPE Cable . Joints are of Insulated joints, Normal straight through joints & Earthing Joints a.Insulated/sheath sectionalizing joints- 6 b.Normal straight through joints-12 c. earthing joints- 3Nos.69661.369661.321.0FalseNoneNoneFalseNoneFalse1462887.30
284138392084NoneUGE8Erection of 220kV Single Phase Link Boxes : Single phase Out door structure mounting type, with Temperature Transducers, Thermocouplers, SVL/CCPU and PVC earthing cable including 1C Copper cable as per the Technical Specifictions Clause 7.04.00 and its Sub-Clauses. Total 12 No -220kVNos.20979.2220979.2212.0FalseNoneNoneFalseNoneFalse251750.640
284138492084NoneUGE9Erection of 220kV Three Phase earth Link Boxes at joint Bay with connecting earth leads all lugs, fixtures, clamps, bolts & nuts complete 3ph Cross Bonding -out door structure mounting type, with Temperature Transducers, Thermocouplers, SVL/CCPU and PVC earthing cable including 1C Copper cable as per the Technical Specifictions Clause 7.04.00 and its Sub-Clauses. -220kV a) Three phase Cross bonding link box with SVL-08 b)Three phase link box without SVL -06Nos62937.6662937.6614.0FalseNoneNoneFalseNoneFalse881127.240
284138592084NoneUGE10Erection of 66kV cross bonding single phase earth link boxes, on to the cable end termination structure connecting earth leads with all lugs, fixtures, clamps, bolts, and nuts completely-66kVNos.17414.8417414.846.0FalseNoneNoneFalseNoneFalse104489.040
284138692084NoneUGE11Erection of three phase earth link boxes on to the cable end termination structure connecting earth leads with all lugs, fixtures, clamps, bolts, and nuts completely-66kVNos52244.552244.53.0FalseNoneNoneFalseNoneFalse156733.50
284138792084NoneUGE12Erection charges for Grounding of equipment by providing cast iron pipe of 100 mm ID 13 mm thickness, 2.75 metre long with 2 part clamp out of G.I. Flat 50 X 6 mm continuously welded alround the pipe using cast iron welding electrodes as per drawing including the cost of excavation etc. complete setSet4119.384119.3824.0FalseNoneNoneFalseNoneFalse98865.120
284138892084NoneUGE13Supplying and fixing 450mm dia x 450mm dia height 1.5 in to 2" thick hume pipe collars (non pressure type) for earth pits including all lead and liftsNos1768.821768.8224.0FalseNoneNoneFalseNoneFalse42451.680
284138992084NoneUGE14Erection of 198kV Lightning Arrestor and wiring including movement from the point of unloading to the point of erection. (Insulation resistance test, leakage current test, surge counter operation test) as per specificationNos668.67668.676.0FalseNoneNoneFalseNoneFalse4012.020
284139092084NoneUGE15Fibre optic cable & accessories: Stringing unarmoured, underground FO cable (48 Fibre DWSM) for LILO portionKms44840.044840.07.33FalseNoneNoneFalseNoneFalse328677.20
284139192084NoneUGE16Handling & making normal straight joint closures for 48 Fibre (DWSM) optical fibre cable with all consumables at site complete.Nos.7858.87858.84.0FalseNoneNoneFalseNoneFalse31435.20
284139292084NoneUGE17UG OFC to OPGW joint kitNos14064.4214064.421.0FalseNoneNoneFalseNoneFalse14064.420
284139392084NoneUGE18Erection of Tower & CTT (including tower accessories,etc., except GI angle with Barbed wire & Grounding materials)- Note: 1. The Bidders are required to quote the rates taking into consideration of the charges for sorting of towers, loading, unloading, stub setting, aligning, dismantling & transportation of templates from one location to another .MT7334.847334.8472.7017FalseNoneNoneFalseNoneFalse533255.3372280
284139492084NoneUGE19Fixing of Tower Accessories: i) Supplying and fixing GI angle 45 x 45 x 5 mm 1Mtr length with cleats, bolts nuts as per specification and fixing above 0.5 mts length each at inner and outer surface of tower to facilitate running of barbed wire AC device,Set4862.784862.782.0FalseNoneNoneFalseNoneFalse9725.560
284139592084NoneUGE20Supplying and fixing Barbed wireRmtr89.6889.68351.36FalseNoneNoneFalseNoneFalse31509.96480
284139692084NoneUGE21Erection charges for Grounding of tower with GI Pipe including the cost of 40mm dia 2.5 mm thick, class 'C' GI pipe of 3mtrs length aspoer specifications, with 50x60 mm GI flats 3mtr long, salt, charcoal including excavation and fixing charges.Set2490.982490.982.0FalseNoneNoneFalseNoneFalse4981.960
284139792084NoneUGE22Stringing of AAAC Moose ACSR Conductor,Kms15340.015340.00.365FalseNoneNoneFalseNoneFalse5599.10
284139892084NoneUGE23Stringing of GROUND Conductor in the lineKms12980.012980.00.061FalseNoneNoneFalseNoneFalse791.780
284139992084NoneUGE24Releasing & Restringing of existing AAAC Moose conductor (500 mts for back span)Kms30680.030680.03.0FalseNoneNoneFalseNoneFalse92040.00
284140092084NoneUGE25Releasing & restringing of existing Ground conductor (500 mts for back span)Kms25960.025960.00.5FalseNoneNoneFalseNoneFalse12980.00
17091154350001NoneNoneSub-StationCivil Works portion199363515.01
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
284140192085NoneCVL1Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depthCum95.095.05912.0FalseNoneNoneFalseNoneFalse561640.00
284140292085NoneCVL2Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in ordinary/soft rock without blasting upto 1.5m depth as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.Cum362.0362.04434.0FalseNoneNoneFalseNoneFalse1605108.00
284140392085NoneCVL3Construction of Embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded with desired compaction.Cum119.0119.05912.0FalseNoneNoneFalseNoneFalse703528.00
284140492085NoneCVL4Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling, water,all materials,usage& all other appurtenaces required to complete the work.Cum474.0474.05725.0FalseNoneNoneFalseNoneFalse2713650.00
284140592085NoneCVL5Removal of Unserviceable Soil/Rock with Disposal upto a suitable distance as directed by the Engineer incharge of workCum85.085.021066.5FalseNoneNoneFalseNoneFalse1790652.50
284140692085NoneCVL6Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 mCum102.0102.08451.2FalseNoneNoneFalseNoneFalse862022.40
284140792085NoneCVL7Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights,including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth.Cum363.0363.05642.59FalseNoneNoneFalseNoneFalse2048260.170
284140892085NoneCVL8Earth work excavation for pipeline trenches by mechanical means as per drawing and technical specification, including setting out, construction of shoring, strutting, cost of blasting materials, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work and all other appurtenances to complete in the following strata. Hard rock (blasting prohibited) Depth upto 1.50 m - For yard levelling and FoundationCum1014.01014.010076.59FalseNoneNoneFalseNoneFalse10217662.260
284140992085NoneCVL9Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum5664.05664.0712.53FalseNoneNoneFalseNoneFalse4035769.920
284141092085NoneCVL10Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, form work, centering & scaffolding and all the other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For foundationCum6475.616475.612392.99FalseNoneNoneFalseNoneFalse15496069.97390
284141192085NoneCVL11Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, form work, centering & scaffolding and all the other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For foundation of drainsCum8487.458487.45164.15FalseNoneNoneFalseNoneFalse1393214.91750
284141292085NoneCVL12Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, form work, centering & scaffolding and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For PBCum9484.59484.523.44FalseNoneNoneFalseNoneFalse222316.680
284141392085NoneCVL13Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing, form work, centering & scaffolding and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Beams & lintels Ground floorCum10608.010608.070.67FalseNoneNoneFalseNoneFalse749667.360
284141492085NoneCVL14Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing, form work, centering & scaffolding and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Beams & lintels - First FllorCum10714.0810714.0811.68FalseNoneNoneFalseNoneFalse125140.45440
284141592085NoneCVL15Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing, form work, centering & scaffolding and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Roof slab - Ground floor & Stair caseCum9945.09945.0112.87FalseNoneNoneFalseNoneFalse1122492.150
284141692085NoneCVL16Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing, form work, centering & scaffolding and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Roof slab - First FloorCum10044.4510044.4515.69FalseNoneNoneFalseNoneFalse157597.42050
284141792085NoneCVL17Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing, form work, centering & scaffolding and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For columns of super structure - Ground floorCum11271.011271.083.59FalseNoneNoneFalseNoneFalse942142.890
284141892085NoneCVL18Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing, form work, centering & scaffolding and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For columns of super structure - First floorCum11383.7111383.7110.15FalseNoneNoneFalseNoneFalse115544.65650
284141992085NoneCVL19Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing, form work, centering & scaffolding and all the other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For column upto PBCum10687.910687.925.95FalseNoneNoneFalseNoneFalse277351.0050
284142092085NoneCVL20Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing, form work, centering & scaffolding and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Chejjas & Canopy of CRBCum9613.59613.515.75FalseNoneNoneFalseNoneFalse151412.6250
284142192085NoneCVL21Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, form work, centering & scaffolding and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregateCum6403.516403.51139.02FalseNoneNoneFalseNoneFalse890215.96020
284142292085NoneCVL22Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregatesCum6596.126596.12318.85FalseNoneNoneFalseNoneFalse2103172.8620
284142392085NoneCVL23Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification BuildingsKg89.4689.4648272.07FalseNoneNoneFalseNoneFalse4318419.38220
284142492085NoneCVL24Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification All other type of structuresKg79.0179.01180605.57FalseNoneNoneFalseNoneFalse14269646.08570
284142592085NoneCVL25Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg113.0113.070149.54FalseNoneNoneFalseNoneFalse7926898.020
284142692085NoneCVL26Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum266.0266.07762.37FalseNoneNoneFalseNoneFalse2064790.420
284142792085NoneCVL27Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specificationsSqm1310.01310.01141.72FalseNoneNoneFalseNoneFalse1495653.20
284142892085NoneCVL28Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm333.0333.06375.18FalseNoneNoneFalseNoneFalse2122934.940
284142992085NoneCVL29Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-harge.Sqm241.0241.0977.43FalseNoneNoneFalseNoneFalse235560.630
284143092085NoneCVL30Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work over one coat of primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm180.0180.01283.13FalseNoneNoneFalseNoneFalse230963.40
284143192085NoneCVL31Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm174.0174.05035.06FalseNoneNoneFalseNoneFalse876100.440
284143292085NoneCVL32Finishing with Epoxy paint (two coats) at all locations prepared and applied as per manufacturer's pecifications including appropriate priming coat, preparation of surface, etc. complete. On concrete work including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm172.0172.0230.28FalseNoneNoneFalseNoneFalse39608.160
284143392085NoneCVL33Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm138.0138.059.91FalseNoneNoneFalseNoneFalse8267.580
284143492085NoneCVL34Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm100.0100.01079.83FalseNoneNoneFalseNoneFalse107983.00
284143592085NoneCVL35Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm139.0139.015.93FalseNoneNoneFalseNoneFalse2214.270
284143692085NoneCVL36Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. (Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colour and shade)Sqm841.0841.01073.82FalseNoneNoneFalseNoneFalse903082.620
284143792085NoneCVL37Fencing with G.I. barbed wire Angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used.. With G.I. barbed wirem18.018.05928.0FalseNoneNoneFalseNoneFalse106704.00
284143892085NoneCVL38Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum7969.07969.0300.57FalseNoneNoneFalseNoneFalse2395242.330
284143992085NoneCVL39Providing S&S RCC SPUN / VIBRATED CAST PIPES (REINFORCED) pipes NP-3 Class conforming to IS:458-1988 with latest amentments using ordinary portland cement, for sanitary works and conveying to work site, rolling and lowering into trenches, laying true to line and level including loading and unloading at both destinations and jointing of pipes and specials, perfect linking of joints with jack to correct position including cost of jointing materials, i.e, rubber rings conforming to IS: 5382 for S&S RCC pipes, with all leads and lifts as directed and giving necessary hydraulic test as per ISS to the required pressure and commissioning etc. complete. (Contractor will make his own arrangements for procuring water for testing). Before the execution of the work, the contractor shall carry out the survey. RCC NP3 Class pipe of 450 mm diam2353.02353.030.0FalseNoneNoneFalseNoneFalse70590.00
284144092085NoneCVL40Providing S&S RCC SPUN / VIBRATED CAST PIPES (REINFORCED) pipes NP-3 Class conforming to IS:458-1988 with latest amentments using ordinary portland cement, for sanitary works and conveying to work site, rolling and lowering into trenches, laying true to line and level including loading and unloading at both destinations and jointing of pipes and specials, perfect linking of joints with jack to correct position including cost of jointing materials, i.e, rubber rings conforming to IS: 5382 for S&S RCC pipes, with all leads and lifts as directed and giving necessary hydraulic test as per ISS to the required pressure and commissioning etc. complete. (Contractor will make his own arrangements for procuring water for testing). Before the execution of the work, the contractor shall carry out the survey. RCC NP3 Class pipe of 300 mm diam1332.01332.050.0FalseNoneNoneFalseNoneFalse66600.00
284144192085NoneCVL41Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6389.06389.01400.65FalseNoneNoneFalseNoneFalse8948752.850
284144292085NoneCVL42Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge.Sqm255.0255.01568.6FalseNoneNoneFalseNoneFalse399993.00
284144392085NoneCVL43Cutting transverse contraction joints in concrete road using concrete cutting machine with diamond studded saw as per standard technical specificatio and direction of engineer incharge of work including cost of materials, labours etc., complete.m70.070.0195.0FalseNoneNoneFalseNoneFalse13650.00
284144492085NoneCVL44Providing and filling joint sealing compound as per approved drawing and technical specification with coarse sand and 6 percent bitumen by weight.m48.048.0195.0FalseNoneNoneFalseNoneFalse9360.00
284144592085NoneCVL45Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications.Kg571.0571.0904.46FalseNoneNoneFalseNoneFalse516446.660
284144692085NoneCVL46Providing and fixing double action hydraulic floor spring of approved brand manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge: With brass cover plate minimum 1.25 mm thickness including cost of materials, labour, usage charges of machinery complete as per specifications.No2804.02804.014.0FalseNoneNoneFalseNoneFalse39256.00
284144792085NoneCVL47FALSE CEILING Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per m2 including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all T sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge.Sqm1693.01693.0203.3FalseNoneNoneFalseNoneFalse344186.90
284144892085NoneCVL48Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete.No237.0237.028.0FalseNoneNoneFalseNoneFalse6636.00
284144992085NoneCVL49Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type)No275.0275.042.0FalseNoneNoneFalseNoneFalse11550.00
284145092085NoneCVL50Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. completeNo130.0130.028.0FalseNoneNoneFalseNoneFalse3640.00
284145192085NoneCVL51Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete including cost of materials, labour, usage charges of machinery complete as per specificationsNo437.0437.026.0FalseNoneNoneFalseNoneFalse11362.00
284145292085NoneCVL52Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. completeNo1052.01052.026.0FalseNoneNoneFalseNoneFalse27352.00
284145392085NoneCVL53supplying and fixing hold fastsNo50.050.0102.0FalseNoneNoneFalseNoneFalse5100.00
284145492085NoneCVL54Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of ngineer-in charge: Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side including cost of materials, labour, usage charges of machinery complete as per specifications.Sqm897.0897.016.28FalseNoneNoneFalseNoneFalse14603.160
284145592085NoneCVL55Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/m²) including cost of materials, labour, usage charges of machinery complete as per specificationsSqm1171.01171.0110.73FalseNoneNoneFalseNoneFalse129664.830
284145692085NoneCVL56Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540- F & ISO 11600 Upto 20 mm depth and 20 mm width including cost of materials, labour, usage charges of machinery complete as per specifications.m296.0296.0435.6FalseNoneNoneFalseNoneFalse128937.60
284145792085NoneCVL57Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specificationsCum124202.0124202.00.87FalseNoneNoneFalseNoneFalse108055.740
284145892085NoneCVL58Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. 30 mm thick Both side teakSqm4043.04043.023.03FalseNoneNoneFalseNoneFalse93110.290
284145992085NoneCVL59Providing and fixing in position fully panelled Honne wood shutters for doors with , stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures)Sqm7085.07085.03.6FalseNoneNoneFalseNoneFalse25506.00
284146092085NoneCVL60Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent..Sqm2852.02852.0357.59FalseNoneNoneFalseNoneFalse1019846.680
284146192085NoneCVL61Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., completeSqm889.0889.026.14FalseNoneNoneFalseNoneFalse23238.460
284146292085NoneCVL62Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.Sqm1449.01449.0164.4FalseNoneNoneFalseNoneFalse238215.60
284146392085NoneCVL63Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding for Bathrooms: Toilet: Chemically exposed areas and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) with Acid and alkali resistant tile - For dadooingSqm1260.01260.055.01FalseNoneNoneFalseNoneFalse69312.60
284146492085NoneCVL64Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding for Bathrooms: Toilet: Chemically exposed areas and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direc tion of Engineer-in- Charge. In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) with Acid and alkali resistant tile - For FlooringSqm1246.01246.044.95FalseNoneNoneFalseNoneFalse56007.70
284146592085NoneCVL65Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm8276.08276.014.58FalseNoneNoneFalseNoneFalse120664.080
284146692085NoneCVL66Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.Kg168.0168.066.15FalseNoneNoneFalseNoneFalse11113.20
284146792085NoneCVL67Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-ChargeKg565.0565.01107.66FalseNoneNoneFalseNoneFalse625827.90
284146892085NoneCVL68Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) greater than 78, solar reflection greater than 0.70 and initial emittance greater than 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner as per direction of inchargeSqm1405.01405.0939.74FalseNoneNoneFalseNoneFalse1320334.70
284146992085NoneCVL69Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 90mm dia.,6 kg/sqcm & class 3m294.0294.060.0FalseNoneNoneFalseNoneFalse17640.00
284147092085NoneCVL70Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3m411.0411.0657.2FalseNoneNoneFalseNoneFalse270109.20
284147192085NoneCVL71Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 160 mm dia., 6 kg/sqcm & class 3m618.0618.01699.78FalseNoneNoneFalseNoneFalse1050464.040
284147292085NoneCVL72Providing & fixing CPVC pipes having thermal stablity for hot & cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00M spacing. this includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per specifications - 32mm nominal dia pipes.m400.0400.0184.28FalseNoneNoneFalseNoneFalse73712.00
284147392085NoneCVL73Providing & fixing CPVC pipes having thermal stablity for hot & cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00M spacing. this includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per specifications - 20mm nominal dia pipes.m242.0242.044.0FalseNoneNoneFalseNoneFalse10648.00
284147492085NoneCVL74Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:.White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap.No2561.02561.05.0FalseNoneNoneFalseNoneFalse12805.00
284147592085NoneCVL75Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required. One urinal basin with 5 litre white P.V.C. automatic flushing cisternNo4454.04454.03.0FalseNoneNoneFalseNoneFalse13362.00
284147692085NoneCVL76Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing. Rectangular shape 453x357 mm,No1018.01018.04.0FalseNoneNoneFalseNoneFalse4072.00
284147792085NoneCVL77Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 32 mm dia,No76.076.04.0FalseNoneNoneFalseNoneFalse304.00
284147892085NoneCVL78Providing and fixing 100 mm sand cast Iron grating for gully trap.No47.047.07.0FalseNoneNoneFalseNoneFalse329.00
284147992085NoneCVL79Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.No496.0496.03.0FalseNoneNoneFalseNoneFalse1488.00
284148092085NoneCVL80Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.No272.0272.05.0FalseNoneNoneFalseNoneFalse1360.00
284148192085NoneCVL81Providing and fixing vitreous china dual purpose closet suitable for use as squatting pan or European type water closet (Anglo Indian W.C pan) with seat & lid fixed with C.P. brass hinges and rubber buffers, 10 litre low level flushing cistern with fitting and brackets, 40 mm flush bend, 20 mm over flow pipe, with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: White vitreous china dual purpose WC pan with white solid plastic seat and lid with white vitreous china flushing cistern and C.P. flush bend.,No8632.08632.03.0FalseNoneNoneFalseNoneFalse25896.00
284148292085NoneCVL82Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:. White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot restsNo4884.04884.02.0FalseNoneNoneFalseNoneFalse9768.00
284148392085NoneCVL83Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittingsNo1423.01423.05.0FalseNoneNoneFalseNoneFalse7115.00
284148492085NoneCVL84Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms.No306.0306.07.0FalseNoneNoneFalseNoneFalse2142.00
284148592085NoneCVL85Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 32 mm nominal bore.No598.0598.01.0FalseNoneNoneFalseNoneFalse598.00
284148692085NoneCVL86Providing and fixing C.P. brass bib cock of approved quality conforming to IS:893.No635.0635.04.0FalseNoneNoneFalseNoneFalse2540.00
284148792085NoneCVL87Supplying and filling Brick Bats of size 25 to100 mm to soak pit as per direction of Engineer Incharge of workCum800.0800.029.86FalseNoneNoneFalseNoneFalse23888.00
284148892085NoneCVL88Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6618.06618.011.65FalseNoneNoneFalseNoneFalse77099.70
284148992085NoneCVL89Providing and fixing Rainy dual capacity self-cleaning roof top rain water harvesting filter or equivalent filter of FL-500 specification suitable for a catchment area of about 500 Sqm.No10500.010500.01.0FalseNoneNoneFalseNoneFalse10500.00
284149092085NoneCVL90Providing & fixing 1.5HP mono submersible pump set for rain water sump with electrification including necessary cables and control panels.No10000.010000.02.0FalseNoneNoneFalseNoneFalse20000.00
284149192085NoneCVL91Sinking borewell of 165mm dia. clear, using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: Borewell depth of 0 to 50 m - Water supply Upto 50.00 mtrs.m370.0370.0100.0FalseNoneNoneFalseNoneFalse37000.00
284149292085NoneCVL92Sinking borewell of 165mm dia. clear, using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for:Borewell depth of 50 to 100 mm464.0464.0100.0FalseNoneNoneFalseNoneFalse46400.00
284149392085NoneCVL93Sinking borewell of 165mm dia. clear, using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: Borewell depth of 100 to 150 mm493.0493.0100.0FalseNoneNoneFalseNoneFalse49300.00
284149492085NoneCVL94Sinking borewell of 165mm dia. clear, using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: Borewell depth of 150 to 200 mm572.0572.0100.0FalseNoneNoneFalseNoneFalse57200.00
284149592085NoneCVL95Sinking borewell of 165mm dia. clear, using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: Borewell depth of 200 to 250 mm671.0671.0100.0FalseNoneNoneFalseNoneFalse67100.00
284149692085NoneCVL96Sinking borewell of 165mm dia. clear, using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: Borewell depth of 250 to 300 mm740.0740.0100.0FalseNoneNoneFalseNoneFalse74000.00
284149792085NoneCVL97Sinking borewell of 165mm dia. clear, using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: Borewell depth of 300 to 350 mm868.0868.0100.0FalseNoneNoneFalseNoneFalse86800.00
284149892085NoneCVL98Sinking borewell of 165mm dia. clear, using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: Borewell depth of 350 to 400 mm937.0937.0100.0FalseNoneNoneFalseNoneFalse93700.00
284149992085NoneCVL99Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium dutym1933.01933.050.0FalseNoneNoneFalseNoneFalse96650.00
284150092085NoneCVL100Providing and laying at site of work MS casing caps as per IS 1239 (part- II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in chargeEach164.0164.02.0FalseNoneNoneFalseNoneFalse328.00
284150192085NoneCVL101Geophysical investigation at site for sinking borewells for supplying drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers’s method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc.Each5288.05288.02.0FalseNoneNoneFalseNoneFalse10576.00
284150292085NoneCVL102PUMPSET : Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest ammendments etc. complete 5.00 HP 50 STGEach29650.029650.02.0FalseNoneNoneFalseNoneFalse59300.00
284150392085NoneCVL103SUBMERSIBLE CABLE Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1x3x4 m2m135.0135.01800.0FalseNoneNoneFalseNoneFalse243000.00
284150492085NoneCVL104PRESSURE GAUGE : Supply and delivery at site of brand new best make pressure gauge bourdon type as per IS 778/1984 with ISI Mark and as per its latest amendments - Size 100 mmEach654.0654.02.0FalseNoneNoneFalseNoneFalse1308.00
284150592085NoneCVL105GATE VALVE : Supply and delivery at site of brand new best make gate valve as per IS 778/1984 with ISI Mark and as per its latest amendments Size 50 mmEach1250.01250.02.0FalseNoneNoneFalseNoneFalse2500.00
284150692085NoneCVL106NON - RETURN VALVE : Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments Size 50 mmEach1250.01250.02.0FalseNoneNoneFalseNoneFalse2500.00
284150792085NoneCVL107Control Panel BOARD-A: Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor typ e NOTE: 1) DOLDirect Online Starter 2)S-D- Star Delta StarterEach9550.09550.02.0FalseNoneNoneFalseNoneFalse19100.00
284150892085NoneCVL108POWER CAPACITOR : Supply and delivery at site best indigenous brand new power capacitor as per IS 2834/1986 with latest amendments with KPTCL authorities and erection, electrification and commissioning of the same at the location of respective pump sets.Kvar550.0550.04.0FalseNoneNoneFalseNoneFalse2200.00
284150992085NoneCVL109MCB : Supply and delivery at site delivery of best indigenous brand new MCB (Miniature Circuit Breakers) of required capacity as per IS 88228/1978 and its latest amendments and with ISI Mark of 6/10/16/20/25/40 Amps with scalable box.Each1150.01150.02.0FalseNoneNoneFalseNoneFalse2300.00
284151092085NoneCVL110HDPE Pipes: Supplying & installation of 50mm dia HDPE pipes of specified grade and confirming to IS standards and direction of engineer in charge of work including cost of labour, materials etc., complete as per specificationm200.0200.0900.0FalseNoneNoneFalseNoneFalse180000.00
284151192085NoneCVL111Erection elctrification & Commissioning works of pumpsets : Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of workNo6500.06500.02.0FalseNoneNoneFalseNoneFalse13000.00
284151292085NoneCVL112Main connections: Providing main connection from pole PVC insulated sheathed steel wire cable in new trench as per IS 1554/ 1988 with latest amendments with ISI mark from KPTCL pole to meter board unit.m135.0135.0100.0FalseNoneNoneFalseNoneFalse13500.00
284151392085NoneCVL113Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work - 50 mm nominal dia Pipesm721.0721.0600.0FalseNoneNoneFalseNoneFalse432600.00
284151492085NoneCVL114Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work - 40 mm nominal dia Pipesm477.0477.0500.0FalseNoneNoneFalseNoneFalse238500.00
284151592085NoneCVL115Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work - 25 mm nominal dia Pipesm296.0296.0150.0FalseNoneNoneFalseNoneFalse44400.00
284151692085NoneCVL116Dismantling of barbed wire fencing/wire mesh fencing including posts, foundation, concrete, backfilling of pit by manual means including disposal of dismantled material with all lifts and lead, stacking serviceable material and unserviceable material seperately.m97.097.01000.0FalseNoneNoneFalseNoneFalse97000.00
284151792085NoneCVL117Dismantling of old size stone masonry including sorting the dismantled material, including disposal of dismantled material with all lifts and lead, stacking serviceable material and unserviceable material seperatelyCum610.0610.0510.0FalseNoneNoneFalseNoneFalse311100.00
284151892085NoneCVL118Clearing and grubbing land including uprooting rank vegitation, grass, bushes, shrubs, saplings and trees, removal of stumps of trees cut earlier and disposal of serviceable material etc., complete as per specification.Sqm3.43.432500.0FalseNoneNoneFalseNoneFalse110500.00
284151992085NoneCVL119Providing and fixing pre moulded multi diameter cable ceiling system of nitrate rubber along with frame shall be provided at the entry of 220kV and 66kV side power/control cables/instrumentation cables into the CRB. The size of the pre moulded cable sealing system shall be suitable for diameter of respective cables.The execution of the fixing of moulds at cable entry shall be done such that it is water proof, fire proof, rodent proof etc.No20000.020000.03.0FalseNoneNoneFalseNoneFalse60000.00
284152092085NoneCVL120Providing and laying Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications - Stone/BoulderCum1912.01912.0315.0FalseNoneNoneFalseNoneFalse602280.00
284152192085NoneCVL121Constructing brick masonry chamber of internal dimension 600 x 600 mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. And Providing & fixing cast iron cover with frame and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge.Each7416.07416.094.0FalseNoneNoneFalseNoneFalse697104.00
284152292085NoneCVL122Constructing brick masonry chamber of internal dimension 450 x 450 mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. And Providing & fixing cast iron cover with frame and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge.Each6198.06198.060.0FalseNoneNoneFalseNoneFalse371880.00
284152392085NoneCVL123Lean concrete: Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:5:10 Using 40 mm and down size graded crushed coarse aggregateCum5338.05338.01771.0FalseNoneNoneFalseNoneFalse9453598.00
284152492085NoneCVL124Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangment and making necessary holes for inlet, outlet and overflow pipes but without fitting and the base support for tank.l9.09.04000.0FalseNoneNoneFalseNoneFalse36000.00
284152592085NoneCVL125Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing, form work, centering & scaffolding and all other appurtenances required to complete the work as per technical specifications. M 40 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7898.17898.197.5FalseNoneNoneFalseNoneFalse770064.750
284152692085NoneCVL126Providing, laying, spreading and compacting graded stone aggregates to wet mix macadam specifications including premixing the materila with water at OMC in mechanical mix plant carriage of mixed material by tipper to site,laying in uniform layers with paver/grader in sub-base/base course on well prepared surface and compacting with vibratory roller to achieve the desired density.Cum2686.952686.95140.4FalseNoneNoneFalseNoneFalse377247.780
284152792085NoneCVL127Construction of subgrade and earther shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requiremnt of table No.300-2Cum493.0493.062.4FalseNoneNoneFalseNoneFalse30763.20
284152892085NoneCVL128Bituminous layer for oil sump: Providing and laying of 1.5 mm thick SBS modified self adhesive single stick waterproofing membrane, with minimum elongation of 300% and puncture resistance of greater than 200 N (as per ASTM E154), with an overlap of 100mm on the side and 100mm in vertical lapping over a coat bituminuos primer @ 0.25 l/m2, complete including surface preparation as per the methodology and site condition & placing the dimple board over the SBS membrane. The cost is nclusive of surface preparation, crack filling, repair of loose mortar etc. completely as per specification.Sqm761.0761.074.4FalseNoneNoneFalseNoneFalse56618.40
284152992085NoneCVL129Jelly Spreading (20-25 mm) : Supplying and providing jelly in the station yard of uniform thickness of 100 mm including the cost of materials, labour charges, required tools and plants etc., complete. Work shall be carried out as per the instructions of Engineer in-charge of works as per the standard procedure.Sqm177.3177.317708.0FalseNoneNoneFalseNoneFalse3139628.40
284153092085NoneCVL130Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specificationsCum160.0160.07642.0FalseNoneNoneFalseNoneFalse1222720.00
284153192085NoneCVL131Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 L per 50 kg of cement or as per direction of Engineer incharge. Ironite flooringSqm800.0800.087.5FalseNoneNoneFalseNoneFalse70000.00
284153292085NoneCVL132Concealed Conduit System Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20mm dia 2mm thickPer Mtr66.066.0440.0FalseNoneNoneFalseNoneFalse29040.00
284153392085NoneCVL133Concealed Conduit System Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25mm dia 2mm thickPer Mtr78.078.0326.0FalseNoneNoneFalseNoneFalse25428.00
284153492085NoneCVL134Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary 19/20mm dia 2mm thickPer Mtr68.068.0238.0FalseNoneNoneFalseNoneFalse16184.00
284153592085NoneCVL135Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary 25mm dia 2mm thickPer Mtr79.079.0238.0FalseNoneNoneFalseNoneFalse18802.00
284153692085NoneCVL136Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 100x75x65mmNo118.0118.010.0FalseNoneNoneFalseNoneFalse1180.00
284153792085NoneCVL137Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 135x75x65mmNo139.0139.05.0FalseNoneNoneFalseNoneFalse695.00
284153892085NoneCVL138Supplying PVC/GI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely. 25mmm22.022.0100.0FalseNoneNoneFalseNoneFalse2200.00
284153992085NoneCVL139Supplying And Fixing Metal Fan Box with Round Hook.No117.0117.018.0FalseNoneNoneFalseNoneFalse2106.00
284154092085NoneCVL140Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. a) Short point up to 3Mtr from tapping point to out let via switch boxEach Point269.0269.040.0FalseNoneNoneFalseNoneFalse10760.00
284154192085NoneCVL141Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. b) Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch boxEach Point379.0379.070.0FalseNoneNoneFalseNoneFalse26530.00
284154292085NoneCVL142Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using copper PVC insulated multi strand 2x1.5Sqmm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.( 4/9) - II. Point wiring using class B Materialsc) Long point above 6Mtr up to 10Mtr from tapping point to out let via switch boxEach Point555.0555.045.0FalseNoneNoneFalseNoneFalse24975.00
284154392085NoneCVL143Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:201 1.5 sqmmm26.026.0630.0FalseNoneNoneFalseNoneFalse16380.00
284154492085NoneCVL144Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:201 2.5 sqmmm42.042.0680.0FalseNoneNoneFalseNoneFalse28560.00
284154592085NoneCVL145Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:201 4 sqmmm63.063.0815.0FalseNoneNoneFalseNoneFalse51345.00
284154692085NoneCVL146Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:201 6 sqmmm92.092.0390.0FalseNoneNoneFalseNoneFalse35880.00
284154792085NoneCVL147Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-2WayEach138.0138.035.0FalseNoneNoneFalseNoneFalse4830.00
284154892085NoneCVL148Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6WayEach220.0220.010.0FalseNoneNoneFalseNoneFalse2200.00
284154992085NoneCVL149Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8WayEach261.0261.08.0FalseNoneNoneFalseNoneFalse2088.00
284155092085NoneCVL150Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12WayEach319.0319.018.0FalseNoneNoneFalseNoneFalse5742.00
284155192085NoneCVL151Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 16WayEach363.0363.012.0FalseNoneNoneFalseNoneFalse4356.00
284155292085NoneCVL152Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 1 to 2 ModuleEach137.0137.035.0FalseNoneNoneFalseNoneFalse4795.00
284155392085NoneCVL153Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 6 ModuleEach234.0234.010.0FalseNoneNoneFalseNoneFalse2340.00
284155492085NoneCVL154Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 8 ModuleEach284.0284.08.0FalseNoneNoneFalseNoneFalse2272.00
284155592085NoneCVL155Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 10-12 ModuleEach344.0344.018.0FalseNoneNoneFalseNoneFalse6192.00
284155692085NoneCVL156Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 16-18 ModuleEach397.0397.012.0FalseNoneNoneFalseNoneFalse4764.00
284155792085NoneCVL157Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6 Amps one way switchEach102.0102.0200.0FalseNoneNoneFalseNoneFalse20400.00
284155892085NoneCVL158Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6 Amps two way switchEach166.0166.04.0FalseNoneNoneFalseNoneFalse664.00
284155992085NoneCVL159Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A Three Way socketEach171.0171.065.0FalseNoneNoneFalseNoneFalse11115.00
284156092085NoneCVL160Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two ModuleEach357.0357.018.0FalseNoneNoneFalseNoneFalse6426.00
284156192085NoneCVL161Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switchEach180.0180.04.0FalseNoneNoneFalseNoneFalse720.00
284156292085NoneCVL162Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A Bell Push.Each177.0177.02.0FalseNoneNoneFalseNoneFalse354.00
284156392085NoneCVL163Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.32A DP SwitchEach326.0326.010.0FalseNoneNoneFalseNoneFalse3260.00
284156492085NoneCVL164Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16A Universal SocketEach236.0236.014.0FalseNoneNoneFalseNoneFalse3304.00
284156592085NoneCVL165Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 6A Lamp Holder.No71.071.012.0FalseNoneNoneFalseNoneFalse852.00
284156692085NoneCVL166Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws,bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR Pole.100 A 25 kANo8487.08487.02.0FalseNoneNoneFalseNoneFalse16974.00
284156792085NoneCVL167Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32A SPEach415.0415.020.0FalseNoneNoneFalseNoneFalse8300.00
284156892085NoneCVL168Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63A SPEach811.0811.018.0FalseNoneNoneFalseNoneFalse14598.00
284156992085NoneCVL169Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A TPNEach1717.01717.06.0FalseNoneNoneFalseNoneFalse10302.00
284157092085NoneCVL170Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPNEach3088.03088.02.0FalseNoneNoneFalseNoneFalse6176.00
284157192085NoneCVL171Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting etc., Made out of 14 SWG MS enclosur - Double Door 12Way SP &NEach2329.02329.06.0FalseNoneNoneFalseNoneFalse13974.00
284157292085NoneCVL172Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.Each9255.09255.01.0FalseNoneNoneFalseNoneFalse9255.00
284157392085NoneCVL173Supplying, fixing and wiring 0 to 1500amps CT operated AC analog type Ammeter With out CTEach480.0480.03.0FalseNoneNoneFalseNoneFalse1440.00
284157492085NoneCVL174Supplying, fixing and wiring 3 Phase Digital Ammeter / VoltmeterEach1425.01425.02.0FalseNoneNoneFalseNoneFalse2850.00
284157592085NoneCVL175Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 A three phase 4 wire whole current class-1 Accuracy Energy Meter.Each5705.05705.01.0FalseNoneNoneFalseNoneFalse5705.00
284157692085NoneCVL176Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each515.0515.03.0FalseNoneNoneFalseNoneFalse1545.00
284157792085NoneCVL177Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.40 x 40 x 6 mmm305.0305.012.0FalseNoneNoneFalseNoneFalse3660.00
284157892085NoneCVL178Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.50 x 50 x 6 mmm395.0395.08.0FalseNoneNoneFalseNoneFalse3160.00
284157992085NoneCVL179Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete - 16SWGSq CM0.430.4385000.0FalseNoneNoneFalseNoneFalse36550.00
284158092085NoneCVL180Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.No1492.01492.05.0FalseNoneNoneFalseNoneFalse7460.00
284158192085NoneCVL181Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. - 15" Sweep (450mm)Each4446.04446.02.0FalseNoneNoneFalseNoneFalse8892.00
284158292085NoneCVL182Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system 48" Sweep (1200mm) Regular modelEach2984.02984.018.0FalseNoneNoneFalseNoneFalse53712.00
284158392085NoneCVL183Supplying wall mounting fan suitable to operate at singlephase 230v AC. supply.400 mm SweepEach3212.03212.010.0FalseNoneNoneFalseNoneFalse32120.00
284158492085NoneCVL184Supplying of .. TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 V with hermetically sealed inverter compressor with air cooled condenser, latest R410A / R-32 refrigerant fan motor, start & run capacitors, relay & over load protector internal unit, with one indoor & one outdoor unit The condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube. suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit.5 star.2 Ton capacityNo67399.067399.010.0FalseNoneNoneFalseNoneFalse673990.00
284158592085NoneCVL185Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette type A/C.No3175.03175.010.0FalseNoneNoneFalseNoneFalse31750.00
284158692085NoneCVL186Supplying and installation of insulated refrigerant copper tubing of 5/8 inch and 3/8 inch with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit Leak testing oil and gas charging for additional piping length of tube Splitm1549.01549.030.0FalseNoneNoneFalseNoneFalse46470.00
284158792085NoneCVL187Extra for Fabrication supply and fixing of Stand fabricated using slotted angle /L angle of size 6mm x 50mm for mounting out door/indoor A.C. unit/ Batteries.m4807.04807.010.0FalseNoneNoneFalseNoneFalse48070.00
284158892085NoneCVL188Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 4' - 20/22 WNo690.0690.063.0FalseNoneNoneFalseNoneFalse43470.00
284158992085NoneCVL189Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clA, Power LEDs with CCT 6500 degree K, CRIgreater than 70%. efficacy greater than 100 lumen per W, 120degree beam spread, lifegreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF greater than 0.95, power loss shouldless than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2'x2' / 40-42 WNo4861.04861.015.0FalseNoneNoneFalseNoneFalse72915.00
284159092085NoneCVL190Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA.On wall/ ceiling / Rafter / Girders.No122.0122.078.0FalseNoneNoneFalseNoneFalse9516.00
284159192085NoneCVL191Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.No171.0171.028.0FalseNoneNoneFalseNoneFalse4788.00
284159292085NoneCVL192Extra length of GI pipe of class B 19mm dia for down rod.No197.0197.030.0FalseNoneNoneFalseNoneFalse5910.00
284159392085NoneCVL193Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frameEach707.0707.07.0FalseNoneNoneFalseNoneFalse4949.00
284159492085NoneCVL194Supplying, erecting, testing and commissioning of voltage stabilizer suitable for 170 to 270 v input and load variation from no load to full load, with over load protection, spike suppression, operating at 00 C to 400 C. Range etc., complete.5kVA CapacityEach9666.09666.01.0FalseNoneNoneFalseNoneFalse9666.00
284159592085NoneCVL195Earthing : Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia.Job3510.03510.010.0FalseNoneNoneFalseNoneFalse35100.00
284159692085NoneCVL196Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mCum242.0242.065.89FalseNoneNoneFalseNoneFalse15945.380
284159792085NoneCVL197Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the Kxcavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: pipeline from borewell to CRB PVC pipes 160mm dia., 6 kg/sqcm & class 3m618.0618.015.0FalseNoneNoneFalseNoneFalse9270.00
284159892085NoneCVL198Earth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. All kind of soil Depth upto 1.50 mCum262.0262.03185.9FalseNoneNoneFalseNoneFalse834705.80
284159992085NoneCVL199Earth work excavation for pipeline trenches by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work and all other appurtenances to complete in the following strata. Ordinary/soft rock (without requiring blasting) Depth upto 1.50 mCum454.0454.01593.04FalseNoneNoneFalseNoneFalse723240.160
284160092085NoneCVL200Earth work excavation for pipeline trenches by mechanical means as per drawing and technical specification, including setting out, construction of shoring, strutting, cost of blasting materials, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work and all other appurtenances to complete in the following strata. Hard rock (blasting prohibited) Depth upto 1.50 mCum1014.01014.03185.9FalseNoneNoneFalseNoneFalse3230502.60
284160192085NoneCVL201Dismantling of Flexible pavements and disposal of dismantled materials and stacking serviceable and unserviceable materials separately By Mechanical Mean Bituminous coursesCum322.0322.02086.97FalseNoneNoneFalseNoneFalse672004.340
284160292085NoneCVL202Dismantling of Flexible pavements and disposal of dismantled materials and stacking serviceable and unserviceable materials separately By Mechanical Mean Granular courseCum53.053.01773.92FalseNoneNoneFalseNoneFalse94017.760
284160392085NoneCVL203Dismantling of cement concrete pavement by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 m3 in volume and stock piling at designated locations and disposal of dismantled materials and stacking serviceable and unserviceable materials separatelyCum563.0563.040.0FalseNoneNoneFalseNoneFalse22520.00
284160492085NoneCVL204Providing M-Sand : Supplying and filling in plinth, foundations / UG cable work with approved M-sand including watering, ramming, consolidating and dressing. The rate includes the cost of material, labour charges, required tools and plants etc., complete. Work shall be carried out as per the instructions of Engineer- in-charge of works as per the standard procedure.Cum1965.01965.07997.25FalseNoneNoneFalseNoneFalse15714596.250
284160592085NoneCVL205Supplying and Providing pre cast RCC Protection Covers using M20 grade Concrete, steel of approved size/shape (as per the approved drawings) to be laid in UG cable works. The rate includes the cost of material, labour charges, loading, unloading, handling, transportation charges, required tools and plants etc., complete. Work shall be carried out as per the instructions of Engineer-in-charge of works as per the standard procedure.Sqm1298.01298.02495.25FalseNoneNoneFalseNoneFalse3238834.50
284160692085NoneCVL206Supplying and Providing Pre cast Cable Route/ Joint marker using M15 grade Concrete, MS rods of approved size/shape (as per the approved drawings) to be laid in UG cable works. The rate includes the cost of material, labour charges, loading, unloading, handling, transportation charges, required tools and plants etc., complete. Work shall be carried out as per the instructions of Engineer-in-charge of works as per the standard procedure.No342.0342.0118.0FalseNoneNoneFalseNoneFalse40356.00
284160792085NoneCVL207Providing and laying of warning tape / Caution tape / detector tape for HDPE pipes of 200 mm wide, 300 micron thick, blue in colour confoming to relevant ISS with latest amendments with appurtenances., complete.m8.08.07250.0FalseNoneNoneFalseNoneFalse58000.00
284160892085NoneCVL208Supplying and construction of RCC M20, 220kV UG cable Joint Bays to accommodate jointing of UG Cable as per specifications, drawings. The rate includes the cost of material, labour charges, curing, form work, centering& scaffolding, loading, unloading, handling, transportation charges, required tools and plants etc., complete. Work shall be carried out as per the instructions of Engineer-in-charge of works as per the standard procedure.No670740.0670740.07.0FalseNoneNoneFalseNoneFalse4695180.00
284160992085NoneCVL209Supplying and construction of RCC M20, 66kV UG Cable Joint Bays to accommodate jointing of UG Cable as per specifications, drawings. The rate includes the cost of material, labour charges, curing, form work, centering& scaffolding, loading, unloading, handling, transportation charges, required tools and plants etc., complete. Work shall be carried out as per the instructions of Engineer-in-charge of works as per the standard procedure.No199742.0199742.07.0FalseNoneNoneFalseNoneFalse1398194.00
284161092085NoneCVL210Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregatesCum6243.06243.0840.0FalseNoneNoneFalseNoneFalse5244120.00
284161192085NoneCVL211HDD method for 220 kV DC UG Cable work: Installation of 6 rows of HDPE pipes PE 80 PN6 of 250 mm dia using Horizontal directional drilling technique (HDD method) including preparing and setting up the plant and equipment,preparing new pipe work materials, installing new pipe work and commissioning system or making the system ready for commissioning by HDD operation including excavation, shoring/ strutting etc., drilling, stringing, ramming and pulling back the new work on the design bore path alignment, proper disposal of drilling fluid and restoration of site after completion etc., for HDD technique suiting Indian conditions in all types of soil- For Double circuit UG CableCkt Mtrs33778.033778.0200.0FalseNoneNoneFalseNoneFalse6755600.00
284161292085NoneCVL212HDD method for laying of 110 kV and 66 kV UG Cables: Installation of 3 rows of HDPE pipes PE 80 PN6 of 160 mm dia using Horizontal directional drilling technique (HDD method) including preparing and setting up the plant and equipment, preparing and installation of new pipe work materials and commissioning system or making the system ready for commissioning by HDD operation including all excavation, shoring/strutting etc., drilling, stringing, ramming and pulling back the new work on the design bore path alignment, proper disposal of drilling fluid and restoration of site after completion etc., for HDD technique suiting Indian conditions in all types of soil.Ckt Mtrs8384.08384.01300.0FalseNoneNoneFalseNoneFalse10899200.00
284161392085NoneCVL213Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. HDPE Grade PE80-PN6.0,250mm diam2170.02170.02160.0FalseNoneNoneFalseNoneFalse4687200.00
284161492085NoneCVL214Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. HDPE Grade PE80-PN6.0,160mm diam959.0959.0720.0FalseNoneNoneFalseNoneFalse690480.00
284161592085NoneCVL215Construction of Granular Sub-Base of grading VI material as per design mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401Cum2533.02533.01620.01FalseNoneNoneFalseNoneFalse4103485.330
284161692085NoneCVL216Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying inuniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired densityCum2559.02559.01759.14FalseNoneNoneFalseNoneFalse4501639.260
284161792085NoneCVL217Prime Coat over WMM/WBM: Providing and applying primer coat with SS1 grade Bitumen Emulsion on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70 kg per m2 using mechanical meansSqm41.041.06956.55FalseNoneNoneFalseNoneFalse285218.550
284161892085NoneCVL218Dense Graded Bituminous Macadam Grading - II for traffic lesser than 20 MSA Providing and laying Dense Graded Bituminous Macadam with 120 TPH capacity HMP batch type using crushed aggregates of specified grading, premixed with bituminous binder VG-30, @ 4.5 per cent by weight of total mix and filler, transporting the hot mix to work site, laying with mechanical paver finisher to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH specification clause No. 505 complete in all respects.Cum9526.09526.0566.74FalseNoneNoneFalseNoneFalse5398765.240
284161992085NoneCVL219Tack coat on Bituminous surface:Providing and applying tack coat with VG-10 Bitumen using pressure distributor at the rate of 0.20 kg/m2 on the prepared bituminous surface cleaned with mechanical broomSqm12.012.06956.55FalseNoneNoneFalseNoneFalse83478.60
284162092085NoneCVL220Bituminous Concrete Grading II for traffic lesser than 20 MSA Providing and laying Bituminous Concrete with 100 TP capacity hot mix plant batch type using crushed aggregates of specified grading, premixed with bituminous binder VG-30, @ 5.4 per cent of mix and filler, transporting the hot mix to work site, laying with mechanical paver finisher to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 507 complete in all respectsCum10865.010865.0323.26FalseNoneNoneFalseNoneFalse3512219.90
284162192085NoneCVL221Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregateCum6217.06217.014.72FalseNoneNoneFalseNoneFalse91514.240
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17091154340001NoneNoneELIGIBILITYTenders from consortium arrangements /Joint ventures are acceptable.None
17091154340000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17091154340000NoneNoneELIGIBILITYThe Tenderer is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of e-Procurement portal due to internet connectivity issues and technical glitches.None
17091154340000NoneNoneELIGIBILITYEMD payments through e-payment mode shall be as single transaction and payment made in part are liable for rejection.None
17091154340000NoneNoneELIGIBILITYBank Guarantee towards EMD over and above Rs.10.00Lakh as per Annexure-II of Section-4 shall be sent in original to Chief Engineer Electy., (T&P), KPTCL, Bengaluru so as to reach this office after the last date of submission of bid and on or before the date & time notified for opening of Techno Commercial Bids, in a sealed cover, failing which their bid will not be opened .None
17091154340000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17091154340000NoneNoneELIGIBILITYTenderer shall upload the legible documents only.None
17091154340000NoneNoneELIGIBILITYBidder shall not take any deviations on the clauses listed in the No Deviation Certificate(Annexure-I)None
17091154340000NoneNoneELIGIBILITYPlease note that the Filled in Techno commercial sheet shall be uploaded along with all other QR documents. Offers shall be quoted in the item-wise bid Financial offer, provisioned in the e-procurement portal. In case the Prices are uploaded in/along the Techno commercial Bid, then Bid will be summarily rejected. The Techno-commercial sheets shall be uploaded in KPTCL excel formats only.None
17091154340000NoneNoneELIGIBILITYAll other terms and conditions as per Tender documentsNone
17091154340000NoneNoneELIGIBILITYThe Tenderer shall upload the scanned copy of the Bank Guarantee towards EMD as per Clause No.13.1 of ITT.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNonePast Experience Documentary proof for Clause No. 3.2(b)(i) of ITT such as P.O, LOI/LOA, DWA, Work done Certificates, Performance Certificates issued by the end users not below the rank of Executive/Divisional EngineerPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- P.O, LOI/LOA, DWA, Work done Certificates, Performance Certificates issued by the end users
NoneNoneNoneNonePast Experience Documentary proof for Clause No. 3.2(b)(ii) of ITT such as P.O, LOI/LOA, DWA, Work done Certificates, Performance Certificates issued by the end users not below the rank of Executive/Divisional EngineerPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Others -- P.O, LOI/LOA, DWA, Work done Certificates, Performance Certificates issued by the end users
NoneNoneNoneNoneAudited financial statements including Balance sheets, Profit and Loss statements, Turnover Certificate, Auditors Reports of the last five years preceding the date of bid submission.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relevant Documents
NoneNoneNoneNoneDocumentary proof for Clause No. 3.2(d) II a) of ITT EHV UG Cable & Cable Accessories (Joints and Terminations) cable manufacturer shall be an ISO 9001/9002 or higher and should have minimum experience of not less than Five (05) years as on the date of bid submission in the design, manufacture, testing, supply of EHV cable of 220kV, 1Cx1200sq.mm or higher size and voltage class, copper/ aluminium conductor, XLPE Insulated, segmental compact type Milliken, lead/corrugated aluminium sheath. Bidder shall upload documentary evidence such as i) P.O. copy (ii) Order completion certificate. (iii) Test certificates in support of the sameOthersRelevant Documents
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relevant Documents
NoneNoneNoneNoneDocumentary proof for Clause No. 3.2(d) II (b) of ITT such as P.O./LOI/LOA/DWA copies/performance certificate issued by the end users i.e. Indian Utility/Consumer not below the rank of Executive Engineer for the cable manufacturer should have supplied copper/aluminium conductor, XLPE Insulated, segmental compact type Milliken, lead/ corrugated aluminium sheath EHV cable of a minimum quantity of 80% of Tendered quantity in India i.e., 19.59km of 220kV or higher voltage category, 1Cx1200sq.mm or higher size EHV cable & 9.35km of 66kV or above voltage class, 1Cx1000sq.mm or higher size EHV cable and the same shall be in satisfactory service for a minimum period of two (02) years in last ten years as on the date of Bid Submission.OthersRelevant Documents
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relevant Documents
NoneNoneNoneNoneDocumentary proof for Clause No. 3.2(d) II (c) of ITT For cable accessories (i.e. for joints and terminations), the Manufacturer should have a minimum of 5 (Five) years experience as on date of bid submission in design, manufacturing, testing and should have supplied atleast 25% of the tendered quantities in India of 220kV or higher voltage class as tendered. The said quantities should be in successful operation for atleast 02 (Two) years as on the date of bid submissionOthersRelevant Documents
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relevant Documents
NoneNoneNoneNoneDocumentary proof for Clause No. 3.2(d) II (d) of ITT Type Test certificates of Cable & joints & terminations as per relevant IEC standards and KPTCL specifications not older than Ten (10) years as on the last date of submission of bid.OthersRelevant Documents
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relevant Documents
NoneNoneNoneNoneUNDERTAKING-1 Deed of undertaking on Rs.200/- non-judicial stamp paper to guarantee Quality, timely supply, performance and Guarantee obligations as specified for the UG cableOthersUndertaking 1
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Undertakings
NoneNoneNoneNoneUNDERTAKING-1A Deed of undertaking on Rs.200/- non-judicial stamp paper to guarantee Quality, timely supply, performance and Guarantee obligations as specified for the UG cable accessories i.e., Joints and TerminationsOthersUndertaking 1A
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Undertakings
NoneNoneNoneNoneUndertaking-2A Undertaking to conduct special tests on the EHV Cable of 220kV 1200Sq.mm of same Voltage class, design & cross section as tenderedOthersUndertaking 2A
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Undertakings
NoneNoneNoneNoneUNDERTAKING-2B Undertaking to conduct special tests on the EHV Cable of 66kV 1000Sq.mm of same Voltage class, design & cross section as tendered.OthersUndertaking 2B
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Undertakings
NoneNoneNoneNoneUNDERTAKING-3 Undertaking regarding procuring EHV UG cables & their accessoriesOthersUndertaking 3
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Undertakings
NoneNoneNoneNoneUNDERTAKING-4 Undertaking regarding Type tests on UG CableOthersUndertaking 4
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Undertakings
NoneNoneNoneNoneUNDERTAKING-5 Undertaking regarding Type tests on UG Cable accessories.OthersUndertaking 5
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Undertakings
NoneNoneNoneNoneThe bidder shall upload List of test certificates as per Annexure C.OthersTest Certificates
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relevant Documents
NoneNoneNoneNoneConsortium Agreement (if applicable)OthersConsortium Agreement
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Consortium Agreement
NoneNoneNoneNonePower of Attorney in favour of all the persons signing the documents, Power of Attorney for Consortium, combined power of attorney signed by the signatories of all the members of consortium as an evidence of authorization for nominating leader (Prime Bidder) of consortium.OthersPower of Attorney
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Power of Attorney
NoneNoneNoneNoneThe Tenderer shall upload Bankers Certificate duly signed by authorized person in the prescribed format as at Annexure XVIII of Section-4 and as per the clause no.3.3 (b) of ITT (Liquid Assets and /or availability of credit facilities).OthersBankers Certificate
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Bankers Certificate
NoneNoneNoneNoneDocumentary proof for Clause No: 3.6 of ITT: Assessed available tender capacity such as, Statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed countersigned by the Employer in charge, not below the rank of an Executive Engineer or equivalent as sought in Note of the said clause in the prescribed format as in clause No: 1.5 of Qualification Information.OthersAssessed available tender capacity
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relevant Documents
NoneNoneNoneNoneSelf-declaration as sought in Clause No. 3.6 Note (ii) of ITT by the bidder stating that the information with regard to assessed available tender capacity (Works on Hand) furnished are correct as per tender conditionsOthersSelf Declaration
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relevant Documents
NoneNoneNoneNoneTenderer shall upload Constitution or legal status, Place of Registration(upload copy) and Principal place of business of tenderer as per clause No.1.1 of Section-3-Qualification Information.OthersRelevant Documents
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relevant Documents
NoneNoneNoneNoneThe Tenderer shall upload total value of works executed (KPTCL & Non KPTCL works) and payments received in the last five years (in Rs. Lakhs) of Tenderer i.e. for 2018-19 to 2022-23 as per clause no.3.6 of ITT, as in the format at 1.2 of Qualification Information.OthersWorks on Hand
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Works on Hand
NoneNoneNoneNoneThe Tenderer shall upload Qualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awarded as per clause No.1.8 of Section-3-Qualification Information.OthersRelevant Documents
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relevant Documents
NoneNoneNoneNoneLetter of Undertaking as per Annexure-V of Section-4.OthersUndertaking
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Undertaking
NoneNoneNoneNoneTenderers shall upload the Self-declarations in respect of Litigation, disqualification/Black listed due to non-performance, Technical Snag & Risk & cost, Country which shares a land border with India as per clause no. 2.4 (b), (c), (d), (e) & (f) of ITT.OthersSelf Declarations
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Self Declarations
NoneNoneNoneNoneUndertaking to source the supply of equipment/material from KPTCL approved Vendors only as per the QR for Vendor registration, available in the KPTCL website i.e., https://kptcl.karnataka.gov.in, Link Tender and Procurement - application for Vendor registration etcOthersUndertaking
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Undertaking
NoneNoneNoneNoneUndertaking to source the supply of equipment/material from Vendors who meet the eligibility clauses regarding restriction on procurement from a country which shares land border with India as specified in Annexure- XVIIOthersUndertaking
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Undertaking
NoneNoneNoneNoneThe Tenderer shall upload the scanned copy of the Bank Guarantee towards EMD as per Clause No.13.1 of ITT.OthersBank Guarantee
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Bank Guarantee
NoneNoneNoneNoneThe Tenderer shall upload Type test reports as per tender documents / technical specifications for UG cableOthersType Test Reports
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Type Test Reports
NoneNoneNoneNoneThe Tenderer and Consortium Partner (In case of Consortium) shall upload Certificate of Incorporation of the Individual or any relevant document in respect of Partnership/Proprietorship firms as per the tender documentOthersCertificate of Incorporation
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Certificate of Incorporation
NoneNoneNoneNoneThe Tenderer and Consortium Partner (In case of Consortium)shall upload GST registration, PAN etc., of the Tenderer as per clause no.3.10 (xiii) of ITT .OthersRelevant Documents
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- GST, PAN
NoneNoneNoneNoneThe Tenderer and Consortium Partner (In case of Consortium) shall upload valid Super grade Electrical Contractors License issued by the Government of Karnataka as on the date of opening of techno-commercial bid of the Tenderer, failing which the offer is liable to be rejected for clause no.2.3 of ITT.OthersSGL
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- SGL
NoneNoneNoneNoneThe Tenderer shall upload List of Key personnel available and Tools & Plants availableOthersRelevant Documents
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relevant Documents
NoneNoneNoneNoneNo deviation certificateOthersRelevant Documents
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- No deviation certificate
NoneNoneNoneNoneDetails of Works on hand and Ongoing contractual commitmentsOthersRelevant Documents
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relevant Documents
NoneNoneNoneNoneTenderer shall upload Duly filled in Techno Commercial Sheets.OthersRelevant Documents
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Technosheets
NoneNoneNoneNoneAny other required documents as per the qualifying requirements, terms and conditions of the tender, NIT & Technical specifications shall be uploaded.OthersRelevant Documents
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relevant Documents
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Company Registration CertificateTrueTechnical Bid
All other relevant documents specified in the TenderTrueTechnical Bid
Techno Commercial sheets duly filled.TrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1709118379000
version0
createdDateNone
modifiedDateNone
blockNumber3rd floor conference hall, KPTCL, Kaveri Bhavan
streetNone
cityBengaluru
stateKarnataka
pin560009
tenderRecallDTONone