createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1709144461251
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee1950.00
emd193980.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose07-03-2024 16:00:00
tenderQueryClose04-03-2024 11:00:00
technicalBidOpen08-03-2024 16:15:00
publishedDate29-02-2024 00:02:42
publishedByPostRDPR_EE_DIV_KPL
publishedByUserKPE15445 - H SATHYAPPA
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonEXECUTIVE ENGINEER PRE DIVISION KOPPAL
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08539220577
mobileNumberNone
tenderSupplierListNone
tenderSchedule
createdTs1709144461294
version6
createdDateNone
modifiedDateNone
tenderNumberRDPR/2023-24/BD/WORK_INDENT4991
titleConstruction of Building Toilet Cleaning Machine Electrification and Construction of Water Tank to Budagumpa Nandihalli Hulakihal Danapur Bennur Ulenour Somanal Baragur Eliganour Yaradona Kuntoji Karatagi Danapur and Jangmarkalgudi Village in Kanakagiri Taluka Package No 6 (14 Villages)
descriptionConstruction of Building Toilet Cleaning Machine Electrification and Construction of Water Tank to Budagumpa Nandihalli Hulakihal Danapur Bennur Ulenour Somanal Baragur Eliganour Yaradona Kuntoji Karatagi Danapur and Jangmarkalgudi Village in Kanakagiri Taluka Package No 6 (14 Villages)
categoryWORKS
categoryTextWorks
ecv7799520.54
deptNameRural Development and Panchayat Raj Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location948
locationNameRDPR Division Office Koppal
provisionalAmount9699000.0
groupOverheadTotalNone
fileNumberEE/PRED/KPL/KKRDB/KNK/PACKAGE/6
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17091444610000NoneNoneBuildingsSupplying of Toilet Cleaning Machine and Repairs of Electrification at School at Budagumpa Village in Karatagi Taluka33859.0
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
284925792414None3.1.2Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 WayNos147.0147.06.0FalseNoneNoneFalseNoneFalse882.00
284925892414None9.3Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing systemNo1900.01900.04.0FalseNoneNoneFalseNoneFalse7600.00
284925992414None11.14.2Supplying and fixing of slim box fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube.1 x 4' Tube light fittingNos361.0361.02.0FalseNoneNoneFalseNoneFalse722.00
284926092414None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.5 mmMtr26.026.05.0FalseNoneNoneFalseNoneFalse130.00
284926192414None2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 2.5 mmMtr42.042.05.0FalseNoneNoneFalseNoneFalse210.00
284926292414None2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 4 mmMtr63.063.05.0FalseNoneNoneFalseNoneFalse315.00
284926392414NoneBasic RateStainless Steel top loading sanitary Napkin Incinerator Machine Burning ability 500 Kg TimeNo24000.024000.01.0FalseNoneNoneFalseNoneFalse24000.00
17091444610000NoneNoneBuildingsConstruction of Building Toilet Cleaning Machine Electrification and Construction of Water Tank to Nandihalli Govt School231893.01
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
284926492415None1.4Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Cum254.1254.16.75FalseNoneNoneFalseNoneFalse1715.1750
284926592415None1.4Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specificationsCum254.1254.16.75FalseNoneNoneFalseNoneFalse1715.1750
284926692415None2.1.1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the Mix 1:5:10 Using 40 mm nominal size graded crushed coarse aggregates work as per technical specificationsCum5947.25947.21.4FalseNoneNoneFalseNoneFalse8326.080
284926792415None5.2Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6948.96948.91.5FalseNoneNoneFalseNoneFalse10423.350
284926892415None5.3Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6515.256515.251.2FalseNoneNoneFalseNoneFalse7818.30
284926992415None5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6708.456708.452.7FalseNoneNoneFalseNoneFalse18112.8150
284927092415None1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 mCum279.3279.33.6FalseNoneNoneFalseNoneFalse1005.480
284927192415None2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specificationsCum6601.356601.351.1FalseNoneNoneFalseNoneFalse7261.4850
284927292415None2.5.1Providing and removing centering shuttering propping etc and removal of form work for foundation appendix I Percentage on finished rate of concrete per cumSqm3960.813960.810.35FalseNoneNoneFalseNoneFalse1386.28350
284927392415None2.5.1Providing and removing centering shuttering propping etc and removal of form work for foundation appendix I Percentage on finished rate of concrete per cumSqm3300.683300.680.75FalseNoneNoneFalseNoneFalse2475.510
284927492415None2.11Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specificationTonne93929.8593929.850.1FalseNoneNoneFalseNoneFalse9392.9850
284927592415None6.7Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of workCum8621.558621.554.14FalseNoneNoneFalseNoneFalse35693.2170
284927692415None8.6.1Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm339.15339.1551.0FalseNoneNoneFalseNoneFalse17296.650
284927792415None8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm120.75120.7551.0FalseNoneNoneFalseNoneFalse6158.250
284927892415None13.2.1Providing and fixing brass bib cock of approved qualityEach300.3300.35.0FalseNoneNoneFalseNoneFalse1501.50
284927992415None1.6.1Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work In all kinds of soils. Depth upto 1.50mCum508.2508.255.0FalseNoneNoneFalseNoneFalse27951.00
284928092415None9.1.1Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0HDPE Grade PE80-PN6.0, 63mm diaRmtr198.45198.4555.0FalseNoneNoneFalseNoneFalse10914.750
284928192415None1.1.1Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc 75 x 75 x 65 mmNo106.0106.05.0FalseNoneNoneFalseNoneFalse530.00
284928292415None2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch boxNo285.0285.05.0FalseNoneNoneFalseNoneFalse1425.00
284928392415None2.2.1Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxNo394.0394.05.0FalseNoneNoneFalseNoneFalse1970.00
284928492415None2.2.2Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxNo555.0555.05.0FalseNoneNoneFalseNoneFalse2775.00
284928592415None3.8Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screwsSqm0.410.411500.0FalseNoneNoneFalseNoneFalse615.00
284928692415None3.1.2Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 WayEach147.0147.025.0FalseNoneNoneFalseNoneFalse3675.00
284928792415None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 48" Sweep (1200 mm) Regular modeNo1900.01900.04.0FalseNoneNoneFalseNoneFalse7600.00
284928892415None11.13Supplying and fixing of slim patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube.No361.0361.04.0FalseNoneNoneFalseNoneFalse1444.00
284928992415None13.1.1Supplying and Fixing of.mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires. Using 25mm dia G.I.PipeNo978.0978.01.0FalseNoneNoneFalseNoneFalse978.00
284929092415None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.5 mmm26.026.025.0FalseNoneNoneFalseNoneFalse650.00
284929192415None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 2.5 mm2m42.042.025.0FalseNoneNoneFalseNoneFalse1050.00
284929292415None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 4 mm2m63.063.025.0FalseNoneNoneFalseNoneFalse1575.00
284929392415NoneP No 23Pre - Paid Energy Meter Single Phase, 5-30 Amps, 1.0 Accuracy Class with Key Pad Technology consumer interface unit along with pillfer proof box Nos7170.07170.01.0FalseNoneNoneFalseNoneFalse7170.00
284929492415None12.60.1Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is noncorrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm Using 4ft. Copper bonded rod with backfill compoundNos4528.04528.01.0FalseNoneNoneFalseNoneFalse4528.00
284929592415NoneP No 2Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws 19/20 mm dia 2 mm thickMtr69.069.040.0FalseNoneNoneFalseNoneFalse2760.00
284929692415NoneBasic RateStainless Steel Top Loading Sanitary Napkin Incinerator Machine Burning Ability 500 Kg TimeNo24000.024000.01.0FalseNoneNoneFalseNoneFalse24000.00
17091444610000NoneNoneBuildingsConstruction of Building Toilet Cleaning Machine Electrification and Construction of Water Tank to Hulakihal Village564803.53
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
284929792416None1.4Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Cum254.1254.16.75FalseNoneNoneFalseNoneFalse1715.1750
284929892416None2.1.1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the Mix 1:5:10 Using 40 mm nominal size graded crushed coarse aggregates work as per technical specificationsCum5947.25947.21.4FalseNoneNoneFalseNoneFalse8326.080
284929992416None5.2Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6948.96948.91.5FalseNoneNoneFalseNoneFalse10423.350
284930092416None5.3Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6515.256515.251.2FalseNoneNoneFalseNoneFalse7818.30
284930192416None5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6708.456708.452.7FalseNoneNoneFalseNoneFalse18112.8150
284930292416None1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 mCum279.3279.33.6FalseNoneNoneFalseNoneFalse1005.480
284930392416None2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specificationsCum6601.356601.351.1FalseNoneNoneFalseNoneFalse7261.4850
284930492416None2.5.1Providing and removing centering shuttering propping etc and removal of form work for foundation appendix I Percentage on finished rate of concrete per cumSqm3960.813960.810.35FalseNoneNoneFalseNoneFalse1386.28350
284930592416None2.5.1Providing and removing centering shuttering propping etc and removal of form work for foundation appendix I Percentage on finished rate of concrete per cumSqm3300.683300.680.75FalseNoneNoneFalseNoneFalse2475.510
284930692416None2.11Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specificationTonne93929.8593929.850.1FalseNoneNoneFalseNoneFalse9392.9850
284930792416None6.7Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of workCum8621.558621.554.14FalseNoneNoneFalseNoneFalse35693.2170
284930892416None8.6.1Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm339.15339.1551.0FalseNoneNoneFalseNoneFalse17296.650
284930992416None8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm120.75120.7551.0FalseNoneNoneFalseNoneFalse6158.250
284931092416None13.2.1Providing and fixing brass bib cock of approved qualityEach300.3300.35.0FalseNoneNoneFalseNoneFalse1501.50
284931192416None1.6.1Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work In all kinds of soils. Depth upto 1.50mCum508.2508.255.0FalseNoneNoneFalseNoneFalse27951.00
284931292416None9.1.1Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0HDPE Grade PE80-PN6.0, 63mm diaRmtr198.45198.4555.0FalseNoneNoneFalseNoneFalse10914.750
284931392416None15.2Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2 l/per m2 , having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 l/m2 , and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specificationSqm773.85773.85107.1FalseNoneNoneFalseNoneFalse82879.3350
284931492416None15.2Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2 l/per m2 , having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 l/m2 , and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specificationSqm50.450.496.0FalseNoneNoneFalseNoneFalse4838.40
284931592416None2.1.1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Cum5947.25947.210.8FalseNoneNoneFalseNoneFalse64229.760
284931692416None9.12.2Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete Size of Tile 600x600 mmSqm1202.251202.25151.2FalseNoneNoneFalseNoneFalse181780.20
284931792416NoneBasic RateStainless Steel Top Loading Sanitary Napkin Incinerator Machine Burning Ability 500 KgEach25200.025200.01.0FalseNoneNoneFalseNoneFalse25200.00
284931892416None1.1.1Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc 75 x 75 x 65 mmNo106.0106.05.0FalseNoneNoneFalseNoneFalse530.00
284931992416None2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch boxNo285.0285.05.0FalseNoneNoneFalseNoneFalse1425.00
284932092416None2.2.1Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxNo394.0394.05.0FalseNoneNoneFalseNoneFalse1970.00
284932192416None2.2.2Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxNo555.0555.05.0FalseNoneNoneFalseNoneFalse2775.00
284932292416None3.8Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screwsSqm0.410.411500.0FalseNoneNoneFalseNoneFalse615.00
284932392416None3.1.2Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 WayEach147.0147.025.0FalseNoneNoneFalseNoneFalse3675.00
284932492416None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 48" Sweep (1200 mm) Regular modeNo1900.01900.05.0FalseNoneNoneFalseNoneFalse9500.00
284932592416None11.13Supplying and fixing of slim patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube.No361.0361.05.0FalseNoneNoneFalseNoneFalse1805.00
284932692416None13.1.1Supplying and Fixing of.mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires. Using 25mm dia G.I.PipeNo978.0978.01.0FalseNoneNoneFalseNoneFalse978.00
284932792416None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.5 mmm26.026.040.0FalseNoneNoneFalseNoneFalse1040.00
284932892416None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 2.5 mm2m42.042.040.0FalseNoneNoneFalseNoneFalse1680.00
284932992416None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 4 mm2m63.063.040.0FalseNoneNoneFalseNoneFalse2520.00
284933092416None1.1.1Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. Mtr69.069.040.0FalseNoneNoneFalseNoneFalse2760.00
284933192416NoneP No 23Pre - Paid Energy Meter Single Phase, 5-30 Amps, 1.0 Accuracy Class with Card TechnologyNo7170.07170.01.0FalseNoneNoneFalseNoneFalse7170.00
17091444610000NoneNoneBuildingsRepairs of Electrification at Danapur Village16728.0
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
284933292417None1.1.1Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc 75 x 75 x 65 mmNo106.0106.04.0FalseNoneNoneFalseNoneFalse424.00
284933392417None2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch boxNo285.0285.02.0FalseNoneNoneFalseNoneFalse570.00
284933492417None2.2.1Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxNo394.0394.02.0FalseNoneNoneFalseNoneFalse788.00
284933592417None2.2.2Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxNo555.0555.02.0FalseNoneNoneFalseNoneFalse1110.00
284933692417None3.8Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screwsSqm0.410.41600.0FalseNoneNoneFalseNoneFalse246.00
284933792417None3.1.2Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 WayEach147.0147.04.0FalseNoneNoneFalseNoneFalse588.00
284933892417None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 48" Sweep (1200 mm) Regular modeNo1900.01900.02.0FalseNoneNoneFalseNoneFalse3800.00
284933992417None11.13Supplying and fixing of slim patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube.No361.0361.02.0FalseNoneNoneFalseNoneFalse722.00
284934092417None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.5 mmm26.026.017.0FalseNoneNoneFalseNoneFalse442.00
284934192417None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 2.5 mm2m42.042.017.0FalseNoneNoneFalseNoneFalse714.00
284934292417None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 4 mm2m63.063.017.0FalseNoneNoneFalseNoneFalse1071.00
284934392417NoneP No 2Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screwsMtr69.069.025.0FalseNoneNoneFalseNoneFalse1725.00
284934492417None12.60.1Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is noncorrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohmNo4528.04528.01.0FalseNoneNoneFalseNoneFalse4528.00
17091444610000NoneNoneBuildingsConstruction of Building Toilet Electrification at GHPS at Bennur Village1358206.32
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
284934592418None1.4Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Cum254.1254.141.513FalseNoneNoneFalseNoneFalse10548.45330
284934692418None2.1.1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the Mix 1:5:10 Using 40 mm nominal size graded crushed coarse aggregates work as per technical specificationsCum5947.25947.212.72FalseNoneNoneFalseNoneFalse75648.3840
284934792418None5.2Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6948.96948.911.31FalseNoneNoneFalseNoneFalse78592.0590
284934892418None5.3Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6515.256515.258.11FalseNoneNoneFalseNoneFalse52838.67750
284934992418None5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6708.456708.4512.3FalseNoneNoneFalseNoneFalse82513.9350
284935092418None1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 mCum279.3279.345.9FalseNoneNoneFalseNoneFalse12819.870
284935192418None2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specificationsCum6601.356601.3526.33FalseNoneNoneFalseNoneFalse173813.54550
284935292418None2.5.1Providing and removing centering shuttering propping etc and removal of form work for foundation appendix I Percentage on finished rate of concrete per cumSqm3960.813960.815.76FalseNoneNoneFalseNoneFalse22814.26560
284935392418None2.5.1Providing and removing centering shuttering propping etc and removal of form work for foundation appendix I Percentage on finished rate of concrete per cumSqm3300.683300.6813.1FalseNoneNoneFalseNoneFalse43238.9080
284935492418None2.11Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specificationTonne93929.8593929.852.75FalseNoneNoneFalseNoneFalse258307.08750
284935592418None6.7Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of workCum8621.558621.5519.64FalseNoneNoneFalseNoneFalse169327.2420
284935692418NoneI No 2.5.1Providing and removing centering shuttering propping etc and removal of form work for foundation appendix I Percentage on finished rate of concrete per cumSqm330.07330.071.73FalseNoneNoneFalseNoneFalse571.02110
284935792418None2.5.1Providing and removing centering shuttering propping etc and removal of form work for foundation appendix I Percentage on finished rate of concrete per cumSqm660.14660.142.73FalseNoneNoneFalseNoneFalse1802.18220
284935892418None11.34BProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.Sqm192.15192.15177.66FalseNoneNoneFalseNoneFalse34137.3690
284935992418None8.6.1Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-chargeSqm339.15339.1584.78FalseNoneNoneFalseNoneFalse28753.1370
284936092418None8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-chargeSqm279.3279.3115.38FalseNoneNoneFalseNoneFalse32225.6340
284936192418None8.33.1Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm165.9165.984.78FalseNoneNoneFalseNoneFalse14065.0020
284936292418None8.29Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm297.15297.15115.38FalseNoneNoneFalseNoneFalse34285.1670
284936392418None9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mmSqm1202.251202.2557.8FalseNoneNoneFalseNoneFalse69490.050
284936492418None9.34Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications. Sqm1622.251622.2518.7FalseNoneNoneFalseNoneFalse30336.0750
284936592418None12.12Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.Cum130412.1130412.10.24FalseNoneNoneFalseNoneFalse31298.9040
284936692418None12.15Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures )Sqm7816.27816.28.28FalseNoneNoneFalseNoneFalse64718.1360
284936792418None8.49Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Each4.24.27000.0FalseNoneNoneFalseNoneFalse29400.00
284936892418None88.84Providing Wall black boards in 12 mm thick with CM 1:3 and applied with primer and two coats of acrylic black paint including finishing etc completeSqm498.75498.753.6FalseNoneNoneFalseNoneFalse1795.50
284936992418None12.80Providing and fixing door latch with necessary screws etc completeSqm299.25299.253.6FalseNoneNoneFalseNoneFalse1077.30
284937092418None20.27.3Providing and fixing bright finished brass flush bolts with necessary brass screws etc cpmpleteEach172.2172.222.0FalseNoneNoneFalseNoneFalse3788.40
17091444610000NoneNoneBuildingsELECTRIFICATION at GHPS at Yaradona Village34247.0
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
284937192419None1.1.1Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screwsMtr69.069.040.0FalseNoneNoneFalseNoneFalse2760.00
284937292419None1.1.1Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc 75 x 75 x 65 mmNo106.0106.04.0FalseNoneNoneFalseNoneFalse424.00
284937392419None2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch boxNo285.0285.04.0FalseNoneNoneFalseNoneFalse1140.00
284937492419None2.2.1Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxNo394.0394.04.0FalseNoneNoneFalseNoneFalse1576.00
284937592419None2.2.2Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxNo555.0555.04.0FalseNoneNoneFalseNoneFalse2220.00
284937692419None3.8Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screwsSqm0.410.411500.0FalseNoneNoneFalseNoneFalse615.00
284937792419None3.1.2Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 WayEach147.0147.016.0FalseNoneNoneFalseNoneFalse2352.00
284937892419None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 48" Sweep (1200 mm) Regular modeNo1900.01900.02.0FalseNoneNoneFalseNoneFalse3800.00
284937992419None11.13Supplying and fixing of slim patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube.No361.0361.04.0FalseNoneNoneFalseNoneFalse1444.00
284938092419None13.1.1Supplying and Fixing of.mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires. Using 25mm dia G.I.PipeNo978.0978.01.0FalseNoneNoneFalseNoneFalse978.00
284938192419None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.5 mmm26.026.040.0FalseNoneNoneFalseNoneFalse1040.00
284938292419None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 2.5 mm2m42.042.040.0FalseNoneNoneFalseNoneFalse1680.00
284938392419None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 4 mm2m63.063.040.0FalseNoneNoneFalseNoneFalse2520.00
284938492419NoneP No 23Pre - Paid Energy Meter Single Phase, 5-30 Amps, 1.0 Accuracy Class with Key Pad Technology consumer interface unit along with pillfer proof boxNos7170.07170.01.0FalseNoneNoneFalseNoneFalse7170.00
284938592419None12.60.1Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is noncorrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm Using 4ft. Copper bonded rod with backfill compoundNos4528.04528.01.0FalseNoneNoneFalseNoneFalse4528.00
17091444610000NoneNoneBuildingsElectrification works at GHPS at Bennur Village12620.0
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
284938692420None1.1.1Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc 75 x 75 x 65 mmNo106.0106.04.0FalseNoneNoneFalseNoneFalse424.00
284938792420None2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch boxNo285.0285.02.0FalseNoneNoneFalseNoneFalse570.00
284938892420None2.2.1Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxNo394.0394.02.0FalseNoneNoneFalseNoneFalse788.00
284938992420None2.2.2Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxNo555.0555.02.0FalseNoneNoneFalseNoneFalse1110.00
284939092420None3.8Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screwsSqm0.410.411000.0FalseNoneNoneFalseNoneFalse410.00
284939192420None3.1.2Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 WayEach147.0147.05.0FalseNoneNoneFalseNoneFalse735.00
284939292420None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 48" Sweep (1200 mm) Regular modeNo1900.01900.02.0FalseNoneNoneFalseNoneFalse3800.00
284939392420None11.13Supplying and fixing of slim patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube.No361.0361.02.0FalseNoneNoneFalseNoneFalse722.00
284939492420None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.5 mmm26.026.031.0FalseNoneNoneFalseNoneFalse806.00
284939592420None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 2.5 mm2m42.042.031.0FalseNoneNoneFalseNoneFalse1302.00
284939692420None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 4 mm2m63.063.031.0FalseNoneNoneFalseNoneFalse1953.00
17091444610000NoneNoneBuildingsConstruction of Building Toilet Cleaning Machine Electrification and Construction of Water Tank at GHPS at Ulenour Village369553.49
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
284939792421None8.72.1Finishing walls with water proofing cement paint of required shade :Old work (one coats applied @ 2.20 kg/10 m²) over priming coat of primer applied @ 0.80 litrs/10 m² complete including cost of Priming coat including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm91.3591.35515.28FalseNoneNoneFalseNoneFalse47070.8280
284939892421None19.22Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction of Engineer-in-charge.Cum50.450.462.1FalseNoneNoneFalseNoneFalse3129.840
284939992421None2.1.1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum5947.25947.26.21FalseNoneNoneFalseNoneFalse36932.1120
284940092421None9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., completeSize of Tile 600x600 mmSqm1202.251202.2565.28FalseNoneNoneFalseNoneFalse78482.880
284940192421None1.4Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Cum254.1254.16.75FalseNoneNoneFalseNoneFalse1715.1750
284940292421None2.1.1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the Mix 1:5:10 Using 40 mm nominal size graded crushed coarse aggregates work as per technical specificationsCum5947.25947.21.4FalseNoneNoneFalseNoneFalse8326.080
284940392421None5.2Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6948.96948.91.5FalseNoneNoneFalseNoneFalse10423.350
284940492421None5.3Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6515.256515.251.2FalseNoneNoneFalseNoneFalse7818.30
284940592421None5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6708.456708.452.7FalseNoneNoneFalseNoneFalse18112.8150
284940692421None1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 mCum279.3279.33.6FalseNoneNoneFalseNoneFalse1005.480
284940792421None2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specificationsCum6601.356601.351.1FalseNoneNoneFalseNoneFalse7261.4850
284940892421None2.5.1Providing and removing centering shuttering propping etc and removal of form work for foundation appendix I Percentage on finished rate of concrete per cumSqm3960.813960.810.35FalseNoneNoneFalseNoneFalse1386.28350
284940992421None2.5.1Providing and removing centering shuttering propping etc and removal of form work for foundation appendix I Percentage on finished rate of concrete per cumSqm3300.683300.680.75FalseNoneNoneFalseNoneFalse2475.510
284941092421None2.11Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specificationTonne93929.8593929.850.1FalseNoneNoneFalseNoneFalse9392.9850
284941192421None6.7Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of workCum8621.558621.554.14FalseNoneNoneFalseNoneFalse35693.2170
284941292421None8.6.1Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm339.15339.1551.0FalseNoneNoneFalseNoneFalse17296.650
284941392421None8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm120.75120.7551.0FalseNoneNoneFalseNoneFalse6158.250
284941492421None13.2.1Providing and fixing brass bib cock of approved qualityEach300.3300.35.0FalseNoneNoneFalseNoneFalse1501.50
284941592421None1.6.1Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work In all kinds of soils. Depth upto 1.50mCum508.2508.255.0FalseNoneNoneFalseNoneFalse27951.00
284941692421None9.1.1Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0HDPE Grade PE80-PN6.0, 63mm diaRmtr198.45198.4555.0FalseNoneNoneFalseNoneFalse10914.750
284941792421NoneBasic RateStainless Steel Top Loading Sanitary Napkin Incinerator Machine Burning Ability 500 Kg TimeNo24000.024000.01.0FalseNoneNoneFalseNoneFalse24000.00
284941892421None2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point upto 3Mtr from tapping point to out let via switch boxNos285.0285.01.0FalseNoneNoneFalseNoneFalse285.00
284941992421None2.2.1Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxNos394.0394.01.0FalseNoneNoneFalseNoneFalse394.00
284942092421None2.2.3Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxNo555.0555.01.0FalseNoneNoneFalseNoneFalse555.00
284942192421None3.1.2Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 WayNo147.0147.04.0FalseNoneNoneFalseNoneFalse588.00
284942292421None12.60.1Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is noncorrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm Using 4ft. Copper bonded rod with backfill compoundNos4528.04528.01.0FalseNoneNoneFalseNoneFalse4528.00
284942392421None6.3Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing systemNo1900.01900.02.0FalseNoneNoneFalseNoneFalse3800.00
284942492421None11.14.2Supplying and fixing of slim box fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube 1 x 4' Tube light fittingNos361.0361.02.0FalseNoneNoneFalseNoneFalse722.00
284942592421None13.1.1Supplying and Fixing of.mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires.Using 25mm dia G.I.PipNos978.0978.01.0FalseNoneNoneFalseNoneFalse978.00
284942692421NoneP No 6Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.5 mmMtr26.026.05.0FalseNoneNoneFalseNoneFalse130.00
284942792421NoneP No 6Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 2.5 mm2Mtr42.042.05.0FalseNoneNoneFalseNoneFalse210.00
284942892421NoneP No 6Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 4 mmMtr63.063.05.0FalseNoneNoneFalseNoneFalse315.00
17091444610000NoneNoneBuildingsConstruction of Building Toilet Cleaning Machine Electrification and Construction of Water Tank to Somanal Village550938.79
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
284942992422None15.2Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2L/per m2,having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 L/m2, and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm773.85773.85107.1FalseNoneNoneFalseNoneFalse82879.3350
284943092422None19.22Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction of Engineer-in-charge. Cum50.450.4107.1FalseNoneNoneFalseNoneFalse5397.840
284943192422None2.1.1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum5947.25947.210.71FalseNoneNoneFalseNoneFalse63694.5120
284943292422None9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete Size of Tile 600x600 mmSqm1202.251202.25112.8FalseNoneNoneFalseNoneFalse135613.80
284943392422NoneBasic RateRO Water Plant for Hemodialysis 500 Ltrs/Hr Capacity Specifications Plant capacity (Ltrs/Hr) 500 Plant type Microprocessor/microcontroller controlled single stage RO water system ( Feed water TDS more than 500 PPM) System type Online ,Offline Double raw water pump ( one active and the other stand by) No Raw water feed pump capacity (LPH) 1500 Micron particle filter after activated Carbon filter for removing suspended particles more than micron size 5 Distribution of RO plant water sufficient for number of dialysis machines 5-10 Material of Booster pump (offline) Stainless Steel 316Each166950.0166950.01.0FalseNoneNoneFalseNoneFalse166950.00
284943492422NoneBasic RateProviding Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. For 3 HP etc. complete. 3.00 HP - 300 LPM @ 26 m = 5 STG Outlet Dia - 2.50"Each24326.424326.41.0FalseNoneNoneFalseNoneFalse24326.40
284943592422None1.6.1Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.Each24326.424326.41.0FalseNoneNoneFalseNoneFalse24326.40
284943692422None9.11Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0Each198.45198.4570.0FalseNoneNoneFalseNoneFalse13891.50
284943792422NoneBasic RateStainless Steel Top Loading Sanitary Napkin Incinerator Machine Burning Ability 500 Kg TimeEach24000.024000.01.0FalseNoneNoneFalseNoneFalse24000.00
284943892422None3.1.2Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 Way Nos147.0147.06.0FalseNoneNoneFalseNoneFalse882.00
284943992422None6.3Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 48" Sweep (1200 mm) Regular modelNo1900.01900.04.0FalseNoneNoneFalseNoneFalse7600.00
284944092422None11.14.2Supplying and fixing of slim box fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube 1 x 4' Tube light fittingNo361.0361.02.0FalseNoneNoneFalseNoneFalse722.00
284944192422None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.5 mmMtr26.026.05.0FalseNoneNoneFalseNoneFalse130.00
284944292422None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 2.5 mm2Mtr42.042.05.0FalseNoneNoneFalseNoneFalse210.00
284944392422None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 4 mm2Mtr63.063.05.0FalseNoneNoneFalseNoneFalse315.00
17091444610000NoneNoneBuildingsRepairs of School Building and Repairs of Electrification at Baragur School361741.26
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
284944492423None15.2Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2L/per m2,having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 L/m2, and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm773.85773.85162.0FalseNoneNoneFalseNoneFalse125363.70
284944592423None8.72.1Finishing walls with water proofing cement paint of required shade :Old work (one coats applied @ 2.20 kg/10 m²) over priming coat of primer applied @ 0.80 litrs/10 m² complete including cost of Priming coat including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm91.3591.35515.28FalseNoneNoneFalseNoneFalse47070.8280
284944692423None19.22Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction of Engineer-in-chargeCum50.450.4100.3FalseNoneNoneFalseNoneFalse5055.120
284944792423None2.1.2Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates Cum5947.25947.210.03FalseNoneNoneFalseNoneFalse59650.4160
284944892423None9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete Size of Tile 600x600 mmSqm1202.251202.25103.64FalseNoneNoneFalseNoneFalse124601.190
17091444610000NoneNoneBuildingsRepairs of School Building and Repairs of Electrification and Steel Racks at Eliganour Villaget E518334.66
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
284944992424None8.33.1Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm165.9165.9486.0FalseNoneNoneFalseNoneFalse80627.40
284945092424None19.22Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction of Engineer-in-charge.Cum50.450.4144.0FalseNoneNoneFalseNoneFalse7257.60
284945192424None2.1.1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum5947.25947.210.8FalseNoneNoneFalseNoneFalse64229.760
284945292424None9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mmSqm1202.251202.25152.4FalseNoneNoneFalseNoneFalse183222.90
284945392424None22.1Providing and supplying 18mm thick both sides pre laminated cement bonded wood particle board as per IS 15786:2008 of approved brand and shade with suitable full threaded steel screws etcSqm735.0735.0228.0FalseNoneNoneFalseNoneFalse167580.00
284945492424None1.1Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. Mtr69.069.020.0FalseNoneNoneFalseNoneFalse1380.00
284945592424None1.1.1Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc 75 x 75 x 65 mmNo106.0106.02.0FalseNoneNoneFalseNoneFalse212.00
284945692424None2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch boxNo285.0285.02.0FalseNoneNoneFalseNoneFalse570.00
284945792424None2.2.1Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxNo394.0394.02.0FalseNoneNoneFalseNoneFalse788.00
284945892424None2.2.2Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxNo555.0555.02.0FalseNoneNoneFalseNoneFalse1110.00
284945992424None3.8Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screwsSqm0.410.41500.0FalseNoneNoneFalseNoneFalse205.00
284946092424None3.1.2Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 WayEach147.0147.05.0FalseNoneNoneFalseNoneFalse735.00
284946192424None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 48" Sweep (1200 mm) Regular modeNo1900.01900.02.0FalseNoneNoneFalseNoneFalse3800.00
284946292424None11.13Supplying and fixing of slim patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube.No361.0361.02.0FalseNoneNoneFalseNoneFalse722.00
284946392424None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.5 mmm26.026.045.0FalseNoneNoneFalseNoneFalse1170.00
284946492424None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 2.5 mm2m42.042.045.0FalseNoneNoneFalseNoneFalse1890.00
284946592424None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 4 mm2m63.063.045.0FalseNoneNoneFalseNoneFalse2835.00
17091444610000NoneNoneBuildingsConstruction of Building and Repairs of Electrification at Yaradona Village1535233.97
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
284946692425None1.4Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Cum254.1254.149.613FalseNoneNoneFalseNoneFalse12606.66330
284946792425None2.1.1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the Mix 1:5:10 Using 40 mm nominal size graded crushed coarse aggregates work as per technical specificationsCum5947.25947.215.23FalseNoneNoneFalseNoneFalse90575.8560
284946892425None5.2Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6948.96948.99.11FalseNoneNoneFalseNoneFalse63304.4790
284946992425None5.3Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6515.256515.258.54FalseNoneNoneFalseNoneFalse55640.2350
284947092425None5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6708.456708.4512.62FalseNoneNoneFalseNoneFalse84660.6390
284947192425None1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 mCum279.3279.354.06FalseNoneNoneFalseNoneFalse15098.9580
284947292425None2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specificationsCum6601.356601.3529.71FalseNoneNoneFalseNoneFalse196126.10850
284947392425None2.5.1Providing and removing centering shuttering propping etc and removal of form work for foundation appendix I Percentage on finished rate of concrete per cumSqm3960.813960.817.25FalseNoneNoneFalseNoneFalse28715.87250
284947492425None2.5.1Providing and removing centering shuttering propping etc and removal of form work for foundation appendix I Percentage on finished rate of concrete per cumSqm3300.683300.6813.1FalseNoneNoneFalseNoneFalse43238.9080
284947592425None2.11Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specificationTonne93929.8593929.853.14FalseNoneNoneFalseNoneFalse294939.7290
284947692425None6.7Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of workCum8621.558621.5522.1FalseNoneNoneFalseNoneFalse190536.2550
284947792425None8.6.1Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm339.15339.1595.38FalseNoneNoneFalseNoneFalse32348.1270
284947892425None2.5.1Providing and removing centering shuttering propping etc and removal of form work for foundation appendix I Percentage on finished rate of concrete per cumSqm330.07330.072.3FalseNoneNoneFalseNoneFalse759.1610
284947992425None2.5.1Providing and removing centering shuttering propping etc and removal of form work for foundation appendix I Percentage on finished rate of concrete per cumSqm660.14660.143.64FalseNoneNoneFalseNoneFalse2402.90960
284948092425None8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-chargeSqm279.3279.3129.98FalseNoneNoneFalseNoneFalse36303.4140
284948192425None8.33.1Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm165.9165.995.38FalseNoneNoneFalseNoneFalse15823.5420
284948292425None8.29Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm297.15297.15129.98FalseNoneNoneFalseNoneFalse38623.5570
284948392425None9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mmSqm1202.251202.2574.86FalseNoneNoneFalseNoneFalse90000.4350
284948492425None9.34Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications.Sqm1622.251622.2523.1FalseNoneNoneFalseNoneFalse37473.9750
284948592425None12.12Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.Cum130412.1130412.10.29FalseNoneNoneFalseNoneFalse37819.5090
284948692425None12.15Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures )Sqm7816.27816.29.72FalseNoneNoneFalseNoneFalse75973.4640
284948792425None8.49Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.No4.24.27000.0FalseNoneNoneFalseNoneFalse29400.00
284948892425None88.84Providing Wall black boards in 12 mm thick with CM 1:3 and applied with primer and two coats of acrylic emulison black paint including finishing etc completeSqm498.75498.753.6FalseNoneNoneFalseNoneFalse1795.50
284948992425None12.80Providing and fixing door latch with necessary screws etc completeEach299.25299.251.0FalseNoneNoneFalseNoneFalse299.250
284949092425None20.27.3Providing and fixing bright finished brass flush bolts with necessary brass screws etc. complete 100 mmEach172.2172.222.0FalseNoneNoneFalseNoneFalse3788.40
284949192425None1.1.1Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screwsMtr69.069.040.0FalseNoneNoneFalseNoneFalse2760.00
284949292425None1.1.1Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc 75 x 75 x 65 mmNo106.0106.04.0FalseNoneNoneFalseNoneFalse424.00
284949392425None2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch boxNo285.0285.04.0FalseNoneNoneFalseNoneFalse1140.00
284949492425None2.2.1Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxNo394.0394.04.0FalseNoneNoneFalseNoneFalse1576.00
284949592425None2.2.2Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxNo555.0555.04.0FalseNoneNoneFalseNoneFalse2220.00
284949692425None3.8Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screwsSqm0.410.411500.0FalseNoneNoneFalseNoneFalse615.00
284949792425None3.1.2Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 WayEach147.0147.016.0FalseNoneNoneFalseNoneFalse2352.00
284949892425None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 48" Sweep (1200 mm) Regular modeNo1900.01900.06.0FalseNoneNoneFalseNoneFalse11400.00
284949992425None11.13Supplying and fixing of slim patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube.No361.0361.04.0FalseNoneNoneFalseNoneFalse1444.00
284950092425None13.1.1Supplying and Fixing of.mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires. Using 25mm dia G.I.PipeNo978.0978.01.0FalseNoneNoneFalseNoneFalse978.00
284950192425None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.5 mmm26.026.040.0FalseNoneNoneFalseNoneFalse1040.00
284950292425None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 2.5 mm2m42.042.042.0FalseNoneNoneFalseNoneFalse1764.00
284950392425None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 4 mm2m63.063.040.0FalseNoneNoneFalseNoneFalse2520.00
284950492425None12.60.1Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is noncorrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohmNo4528.04528.01.0FalseNoneNoneFalseNoneFalse4528.00
284950592425NoneP No 23Pre - Paid Energy Meter Single Phase, 5-30 Amps, 1.0 Accuracy Class with Key Pad Technology consumer interface unit along with pillfer proof boxNos7170.07170.01.0FalseNoneNoneFalseNoneFalse7170.00
284950692425None1.1.1Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.19/20 mm dia 2 mm thickMtr69.069.020.0FalseNoneNoneFalseNoneFalse1380.00
284950792425None1.1.1Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc 75 x 75 x 65 mmNo106.0106.04.0FalseNoneNoneFalseNoneFalse424.00
284950892425None2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch boxNo285.0285.02.0FalseNoneNoneFalseNoneFalse570.00
284950992425None2.2.1Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxNo394.0394.02.0FalseNoneNoneFalseNoneFalse788.00
284951092425None2.2.2Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxNo555.0555.02.0FalseNoneNoneFalseNoneFalse1110.00
284951192425None3.8Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screwsSqm0.410.411000.0FalseNoneNoneFalseNoneFalse410.00
284951292425None3.1.2Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 WayEach147.0147.05.0FalseNoneNoneFalseNoneFalse735.00
284951392425None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 48" Sweep (1200 mm) Regular modeNo1900.01900.02.0FalseNoneNoneFalseNoneFalse3800.00
284951492425None11.13Supplying and fixing of slim patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube.No361.0361.02.0FalseNoneNoneFalseNoneFalse722.00
284951592425None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.5 mmm26.026.039.0FalseNoneNoneFalseNoneFalse1014.00
284951692425None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 2.5 mm2m42.042.039.0FalseNoneNoneFalseNoneFalse1638.00
284951792425None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 4 mm2m63.063.039.0FalseNoneNoneFalseNoneFalse2457.00
17091444610000NoneNoneBuildingsRepairs of 2 Rooms Building in GHPS at Kuntoji Village348751.98
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
284951892426None3.1Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854No147.0147.08.0FalseNoneNoneFalseNoneFalse1176.00
284951992426None6.3Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.No1900.01900.04.0FalseNoneNoneFalseNoneFalse7600.00
284952092426None11.14.2Supplying and fixing of slim box fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent TubeNo361.0361.04.0FalseNoneNoneFalseNoneFalse1444.00
284952192426None2.6Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.5 mm2Mtr26.026.015.0FalseNoneNoneFalseNoneFalse390.00
284952292426None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 2.5 mmMtr42.042.015.0FalseNoneNoneFalseNoneFalse630.00
284952392426None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 4 mmMtr63.063.015.0FalseNoneNoneFalseNoneFalse945.00
284952492426None15.2Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2L/per m2,having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 L/m2, and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In chargeSqm773.85773.85107.1FalseNoneNoneFalseNoneFalse82879.3350
284952592426None19.22Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction of Engineer-in-charge. Cum50.450.496.0FalseNoneNoneFalseNoneFalse4838.40
284952692426None2.1.1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specificationsCum5947.25947.211.52FalseNoneNoneFalseNoneFalse68511.7440
284952792426None9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., completeSqm1202.251202.25150.0FalseNoneNoneFalseNoneFalse180337.50
17091444610000NoneNoneBuildingsRepairs of 5 Rooms Construction of Boys and Ladies Toilet at PU College in Karatagi1512930.82
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
284952892427None2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6601.356601.3532.59FalseNoneNoneFalseNoneFalse215137.99650
284952992427None19.2.1Demolishing cement concrete manually/ by mechanical means including disposal of material to the appropriate disposal area as per direction of Engineer-in-chargeCum1746.151746.1525.0FalseNoneNoneFalseNoneFalse43653.750
284953092427None2.5.1Providing and removing centering, shuttering, strutting, propping etc.and removal of form work for Foundation, Appendix I Percentage on finished rate of Concrete Per Cum PWD SR 2023-24,P No.111, (Vol-1)Sqm3960.813960.817.59FalseNoneNoneFalseNoneFalse30062.54790
284953192427None2.5.1Providing and removing centering, shuttering, strutting, propping etc.and removal of form work for Foundation, Appendix I Percentage on finished rate of Concrete Per Cum PWD SR 2023-24,P No.111, (Vol-1)Sqm3300.683300.6825.0FalseNoneNoneFalseNoneFalse82517.00
284953292427None2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Tonne93929.8593929.853.41FalseNoneNoneFalseNoneFalse320300.78850
284953392427None8.6.1Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm339.15339.15200.0FalseNoneNoneFalseNoneFalse67830.00
284953492427None12.12Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. Cum130412.1130412.10.52FalseNoneNoneFalseNoneFalse67814.2920
284953592427None12.15Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usagSqm7816.27816.25.04FalseNoneNoneFalseNoneFalse39393.6480
284953692427None12.23Providing and fixing in position Honnewood fully panelled shutters for windows with stiles and rails of 35mm. thick, 75mm wide in two halves with panels of 25mm thick including cost of materials, labour charges, usage charges complete as per specifications. (excluding cost of fixtures)Sqm7952.77952.713.52FalseNoneNoneFalseNoneFalse107520.5040
284953792427None15.2Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2L/per m2,having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 L/m2, and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In chargeSqm773.85773.85185.25FalseNoneNoneFalseNoneFalse143355.71250
284953892427None622Polyethylene Water Storage tank with cover and suitable locking arrangmentLtr6.36.31000.0FalseNoneNoneFalseNoneFalse6300.00
284953992427None13.31.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge Internal work - Exposed on wall 25 mm nominal dia PipesMtr333.9333.960.0FalseNoneNoneFalseNoneFalse20034.00
284954092427NoneI No 77Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm4454.14454.115.75FalseNoneNoneFalseNoneFalse70152.0750
284954192427NoneBasic RateStainless Steel Top Loading Sanitary Napkin Incinerator Machine Burning Ability 500 kg TimeNo20000.020000.01.0FalseNoneNoneFalseNoneFalse20000.00
284954292427None1.1.1Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc 75 x 75 x 65 mmNo106.0106.04.0FalseNoneNoneFalseNoneFalse424.00
284954392427None2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch boxNo285.0285.04.0FalseNoneNoneFalseNoneFalse1140.00
284954492427None2.2.1Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxNo394.0394.04.0FalseNoneNoneFalseNoneFalse1576.00
284954592427None2.2.2Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxNo555.0555.04.0FalseNoneNoneFalseNoneFalse2220.00
284954692427None3.8Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screwsSqm0.410.411500.0FalseNoneNoneFalseNoneFalse615.00
284954792427None3.1.2Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 WayEach147.0147.016.0FalseNoneNoneFalseNoneFalse2352.00
284954892427None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 48" Sweep (1200 mm) Regular modeNo1900.01900.04.0FalseNoneNoneFalseNoneFalse7600.00
284954992427None11.13Supplying and fixing of slim patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube.No361.0361.04.0FalseNoneNoneFalseNoneFalse1444.00
284955092427None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.5 mmm26.026.040.0FalseNoneNoneFalseNoneFalse1040.00
284955192427None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 2.5 mm2m42.042.040.0FalseNoneNoneFalseNoneFalse1680.00
284955292427None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 4 mm2m63.063.040.0FalseNoneNoneFalseNoneFalse2520.00
284955392427None13.1.1SupplyingandFixingof.mmdiaclassAGIpipebracketupto2mslongbentatsuitableangleandfixingtothisbracketstreetlightfittingofallcapacitiestoGIorGIorrailorRCpole/wallusingsuitableclamps,bolts,andnutsandwiringusingsuitablecapacitywires. Using 25mm dia G.I.PipeNo978.0978.01.0FalseNoneNoneFalseNoneFalse978.00
284955492427NoneP No 23Pre - Paid Energy Meter Single Phase, 5-30 Amps, 1.0 Accuracy Class with Key Pad Technology consumer interface unit along with pillfer proof boxNo7170.07170.01.0FalseNoneNoneFalseNoneFalse7170.00
284955592427None1.1.1SupplyingheavygaugePVCconduitpipe.dia.mmthickconfirmingtoIS2509withsuitablesizebends,junctionboxes,adhesivepasteetc,andfixingusinginvertedwoodplugsincaseofRCCceilingandRCCwall/stonestructureorrawlplugsincaseofbrickwallsandcementplasteringthedamagedportionusingheavygauge saddles at an interval of 700mm using NF screws.Mtr69.069.040.0FalseNoneNoneFalseNoneFalse2760.00
284955692427None2.2.1For bathroom room Electrification:SupplyingandwiringadoptingloopsysteminexistingPVCConduit/casingcappingusing2x1.5Sqmm(Phase&Neutral)&1x1.0sqmm(Earthwire)FRLSmultistrandPVCinsulatedcopperwire(confirmingtoIS-694:andlatestamendments)with a6AmpsflushtypeSPcontrolswitchshallbefixedontheexistingplasticsheet/gangbox,theotherendofthewiresshallbeterminatedwithsufficientlooselengthinawood/PVCroundblock.completeforeach outlet.a) Short Point using Class A. MaterialOne285.0285.04.0FalseNoneNoneFalseNoneFalse1140.00
284955792427None2.1.1Mediumpointabove3Mtrupto6MtrfromtappingpointtooutletviaswitchNos394.0394.04.0FalseNoneNoneFalseNoneFalse1576.00
284955892427None2.2.1c) Long Point using Class A. MaterialNo555.0555.04.0FalseNoneNoneFalseNoneFalse2220.00
284955992427None3.1.2Supplying6Aflushtypesocketand6AflushtypeSPswitcheithersurface/flushmountinginexistinggangboxorin4mmthickplasticsheetandfixingoveraflushmountedwoodenboxandwiringusingnecessary capacity wires as required as per IS 1293 and IS 3854Nos147.0147.016.0FalseNoneNoneFalseNoneFalse2352.00
284956092427NoneBasic RateSupplyingof1440rpmheavydutyexhaustfanwithbracketbladessuitable to operate on 230V 50Hz, AC Supply complete.15" Sweep (450 mm)Each4446.04446.04.0FalseNoneNoneFalseNoneFalse17784.00
284956192427None11.14.2Supplyingandfixingofslimboxfitting,madeoutofCRCASheetmetalbodywithlockingtypeholdercompletelywired.ExcludingBallast & Fluorescent Tube. 1 x 4' Tube light fitting.No361.0361.06.0FalseNoneNoneFalseNoneFalse2166.00
284956292427None13.1.1SupplyingandFixingof.mmdiaclassAGIpipebracketupto2mslongbentatsuitableangleandfixingtothisbracketstreetlightfittingofallcapacitiestoGIorGIorrailorRCpole/wallusingsuitableclamps,bolts,andnutsandwiringusingsuitablecapacitywires. Using 25mm dia G.I.PipeEach978.0978.01.0FalseNoneNoneFalseNoneFalse978.00
284956392427NoneP NO 6Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010 1.5 sqmmMtr26.026.060.0FalseNoneNoneFalseNoneFalse1560.00
284956492427NoneP No 6Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010 2.5 sqmmMtr42.042.060.0FalseNoneNoneFalseNoneFalse2520.00
284956592427NoneP No 6Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010 4 sqmmMtr63.063.060.0FalseNoneNoneFalseNoneFalse3780.00
284956692427NoneBasic RateRO Water Plant for Hemodialysis 500 Ltrs/Hr Capacity Specifications Plant capacity (Ltrs/Hr) 500 Plant type Microprocessor/microcontroller controlled single stage RO water system ( Feed water TDS more than 500 PPM) System type Online ,Offline Double raw water pump ( one active and the other stand by) No Raw water feed pump capacity (LPH) 1500 Micron particle filter after activated Carbon filter for removing suspended particles more than micron size 5 Distribution of RO plant water sufficient for number of dialysis machines 5-10 Material of Booster pump (offline) Stainless Steel 316No159000.0159000.01.0FalseNoneNoneFalseNoneFalse159000.00
284956792427None13.4.2Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and 0.50 HP/0.37kW - 7 STG(stage)Each11397.7511397.751.0FalseNoneNoneFalseNoneFalse11397.750
284956892427None1.6.1Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances requiredNo508.2508.255.0FalseNoneNoneFalseNoneFalse27951.00
284956992427None9.1.1Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. comMtr198.45198.4555.0FalseNoneNoneFalseNoneFalse10914.750
17091444610000NoneNoneBuildingsRepairs of School Building and Repairs of Electrification at GHPS Danapur Village in Gangavathi Taluka349678.71
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
284957092428None1.1.1Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.19/20 mm dia 2 mm thickMtr69.069.025.0FalseNoneNoneFalseNoneFalse1725.00
284957192428None1.1.1Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc 75 x 75 x 65 mmNo106.0106.04.0FalseNoneNoneFalseNoneFalse424.00
284957292428None2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch boxNo285.0285.02.0FalseNoneNoneFalseNoneFalse570.00
284957392428None2.2.1Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxNo394.0394.02.0FalseNoneNoneFalseNoneFalse788.00
284957492428None2.2.2Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxNo555.0555.02.0FalseNoneNoneFalseNoneFalse1110.00
284957592428None3.8Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screwsSqm0.410.41600.0FalseNoneNoneFalseNoneFalse246.00
284957692428None3.1.2Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 WayEach147.0147.04.0FalseNoneNoneFalseNoneFalse588.00
284957792428None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 48" Sweep (1200 mm) Regular modeNo1900.01900.02.0FalseNoneNoneFalseNoneFalse3800.00
284957892428None11.13Supplying and fixing of slim patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube.No361.0361.02.0FalseNoneNoneFalseNoneFalse722.00
284957992428None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.5 mmm26.026.013.0FalseNoneNoneFalseNoneFalse338.00
284958092428None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 2.5 mm2m42.042.013.0FalseNoneNoneFalseNoneFalse546.00
284958192428None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 4 mm2m63.063.013.0FalseNoneNoneFalseNoneFalse819.00
284958292428None12.60.1Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is noncorrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm Using 4ft. Copper bonded rod with backfill compoundNos4528.04528.01.0FalseNoneNoneFalseNoneFalse4528.00
284958392428None15.2Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2L/per m2,having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 L/m2, and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm773.85773.85135.0FalseNoneNoneFalseNoneFalse104469.750
284958492428None8.72.1Finishing walls with water proofing cement paint of required shade :Old work (one coats applied @ 2.20 kg/10 m²) over priming coat of primer applied @ 0.80 litrs/10 m² complete including cost of Priming coat including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour compSqm91.3591.35442.2FalseNoneNoneFalseNoneFalse40394.970
284958592428None19.22Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction of Engineer-in-charge.Cum50.450.498.4FalseNoneNoneFalseNoneFalse4959.360
284958692428None2.1.1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the Mix 1:5:10 Using 40 mm nominal size graded crushed coarse aggregates work as per technical specificationsCum5947.25947.29.84FalseNoneNoneFalseNoneFalse58520.4480
284958792428None9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mmSqm1202.251202.25104.08FalseNoneNoneFalseNoneFalse125130.180
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17091444620000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17091444620000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17091444620000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Technical Bid
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Owning the following key and critical equipment for this work
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneList of existing commitments and ongoing worksCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- List of existing commitments and ongoing works
NoneNoneNoneNoneList of works for which tenders already submittedCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneBanker Details for referenceCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Banker Details for reference
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Machineries
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditors reports for the last five yearsFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneITR Filed Copy (Mentioning PAN)
NoneNoneNoneNoneList of Financial Resources with CertificatesFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover Certificate 2018-19 to 2022-23 with UDIN No CompulsoryTrueTechnical Bid
Company Registration CertificateTrueTechnical Bid
Tenderer must Submit PAN & GST Certificate.TrueTechnical Bid
Accurate postal address and phone / cell phone numberTrueTechnical Bid
Work orders / commitments of ongoing works issued by an officer not below the rank of Executive EngineerTrueTechnical Bid
Annual Turnover Certificate 2018-19 to 2022-23 with UDIN No CompulsoryTrueTechnical Bid
SIMILAR NATURE OF WORKDONE FIFTY PERCENTAGE 2018-19 TO 2022-23 FINANCIAL YEARTrueTechnical Bid
Line of Credit 30 PercentageTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone