| tenderSubEstimateList | | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
|---|
| 1709144461000 | 0 | None | None | Buildings | Supplying of Toilet Cleaning Machine and Repairs of Electrification at School at Budagumpa Village in Karatagi Taluka | 33859.0 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 2849257 | 92414 | None | 3.1.2 | Supplying 6A flush type socket and 6 A flush type SP switch either
surface/flush mounting in existing gang box or in 4mm thick plastic
sheet and fixing over a flush mounted wooden box and wiring using
necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 Way | Nos | 147.0 | 147.0 | 6.0 | False | None | None | False | None | False | 882.0 | 0 | | 2849258 | 92414 | None | 9.3 | Supplying capacitor type ceiling fan complete with down rod blades,
shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase
AC supply conforming to ISS-374- 1979 and with double ball bearing
system | No | 1900.0 | 1900.0 | 4.0 | False | None | None | False | None | False | 7600.0 | 0 | | 2849259 | 92414 | None | 11.14.2 | Supplying and fixing of slim box fitting, made out of CRCA Sheet
metal body with locking type holder completely wired. Excluding
Ballast & Fluorescent Tube.1 x 4' Tube light fitting | Nos | 361.0 | 361.0 | 2.0 | False | None | None | False | None | False | 722.0 | 0 | | 2849260 | 92414 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 1.5 mm | Mtr | 26.0 | 26.0 | 5.0 | False | None | None | False | None | False | 130.0 | 0 | | 2849261 | 92414 | None | 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 2.5 mm | Mtr | 42.0 | 42.0 | 5.0 | False | None | None | False | None | False | 210.0 | 0 | | 2849262 | 92414 | None | 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 4 mm | Mtr | 63.0 | 63.0 | 5.0 | False | None | None | False | None | False | 315.0 | 0 | | 2849263 | 92414 | None | Basic Rate | Stainless Steel top loading sanitary Napkin Incinerator Machine Burning ability 500 Kg Time | No | 24000.0 | 24000.0 | 1.0 | False | None | None | False | None | False | 24000.0 | 0 |
| | 1709144461000 | 0 | None | None | Buildings | Construction of Building Toilet Cleaning Machine Electrification and Construction of Water Tank to Nandihalli Govt School | 231893.01 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 2849264 | 92415 | None | 1.4 | Earth work excavation by manual means for drains, canals, waste weir, draft,
approach channels, key trenches, foundation of Buildings & bridges and such
simillar works in all kinds of soils, as per drawing and technical specifications,
including setting out, shoring, strutting, barricading, caution lights, removal
of stumps and other deleterious matter, excavated surface leveled and sides
neatly dressed disposing off the excavated stuff or sorting & stacking the
selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of
labour, tools & other appurtenaces required to complete the work.
| Cum | 254.1 | 254.1 | 6.75 | False | None | None | False | None | False | 1715.175 | 0 | | 2849265 | 92415 | None | 1.4 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in
layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of
machinery, curing, and all the other appurtenances required to complete the
work as per technical specifications | Cum | 254.1 | 254.1 | 6.75 | False | None | None | False | None | False | 1715.175 | 0 | | 2849266 | 92415 | None | 2.1.1 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the Mix 1:5:10 Using 40 mm nominal size graded crushed coarse aggregates work as per technical specifications | Cum | 5947.2 | 5947.2 | 1.4 | False | None | None | False | None | False | 8326.08 | 0 | | 2849267 | 92415 | None | 5.2 | Providing Coursed rubble masonry (first sort) with hard stone in
foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6948.9 | 6948.9 | 1.5 | False | None | None | False | None | False | 10423.35 | 0 | | 2849268 | 92415 | None | 5.3 | Providing Coursed rubble masonry (second sort) with hard stone in
foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6515.25 | 6515.25 | 1.2 | False | None | None | False | None | False | 7818.3 | 0 | | 2849269 | 92415 | None | 5.4 | Providing Size Stone masonry with hard stone in foundation & plinth
with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6708.45 | 6708.45 | 2.7 | False | None | None | False | None | False | 18112.815 | 0 | | 2849270 | 92415 | None | 1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of
foundations and other similar works etc. in layers not exceeding 20cm in depth,
consolidating each deposited layer by ramming and watering, lead up to 50 m
and lift upto 1.5 m | Cum | 279.3 | 279.3 | 3.6 | False | None | None | False | None | False | 1005.48 | 0 | | 2849271 | 92415 | None | 2.2.1 | Providing and laying in position Cement Concrete for all Foundation works.
The granite/trap/basalt crushed graded coarse aggregates and fine aggregates
as per relevant IS Codes machine mixed with super plasticizers laid in finished
layers, well compacted using needle vibrators, including all lead & lifts, cost
of all materials, quality confirming to the requirements of relevant IS codes,
labour, Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications | Cum | 6601.35 | 6601.35 | 1.1 | False | None | None | False | None | False | 7261.485 | 0 | | 2849272 | 92415 | None | 2.5.1 | Providing and removing centering shuttering propping etc and removal of form work for foundation appendix I Percentage on finished rate of concrete per cum | Sqm | 3960.81 | 3960.81 | 0.35 | False | None | None | False | None | False | 1386.2835 | 0 | | 2849273 | 92415 | None | 2.5.1 | Providing and removing centering shuttering propping etc and removal of form work for foundation appendix I Percentage on finished rate of concrete per cum | Sqm | 3300.68 | 3300.68 | 0.75 | False | None | None | False | None | False | 2475.51 | 0 | | 2849274 | 92415 | None | 2.11 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement
including cost of all materials, machinery, labour, cleaning, straightening,
cutting, bending, hooking, laping/welding joints, tying with binding wire / soft
annealed steel wire and other ancilary operations complete as per drawing and
technical specification | Tonne | 93929.85 | 93929.85 | 0.1 | False | None | None | False | None | False | 9392.985 | 0 | | 2849275 | 92415 | None | 6.7 | Providing Brick work with common burnt clay Non Modular bricks
of class designation 3.5 in superstructure above plinth level in all
shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand)
including cost of all materials, labour, scaffolding and usage charges of
machinery & other incidental charges complete as per the direction of
engineer incharge of work | Cum | 8621.55 | 8621.55 | 4.14 | False | None | None | False | None | False | 35693.217 | 0 | | 2849276 | 92415 | None | 8.6.1 | Providing 12 mm cement plaster with Cement mortar 1:3 (1
cement: 3 coarse sand) finished with a floating coat of neat cement
to brick masonry including rounding off corners wherever required
smooth rendering, providing and removing scaffolding, including cost
of materials, labour, curing complete as per specifications and as per
directions of Engineer-in-charge. | Sqm | 339.15 | 339.15 | 51.0 | False | None | None | False | None | False | 17296.65 | 0 | | 2849277 | 92415 | None | 8.40 | Painting with synthetic enamel paint of approved brand and
manufacture to give an even shade :Two coats on new work after
thoroughly brooming the surface to remove all dirt, dust, mortar drops
and foreign matter including preparing the surface even and sand paper
smooth, cost of materials, labour complete as per specifications and as
per directions of Engineer-in-charge. | Sqm | 120.75 | 120.75 | 51.0 | False | None | None | False | None | False | 6158.25 | 0 | | 2849278 | 92415 | None | 13.2.1 | Providing and fixing brass bib cock of approved quality | Each | 300.3 | 300.3 | 5.0 | False | None | None | False | None | False | 1501.5 | 0 | | 2849279 | 92415 | None | 1.6.1 | Earth work excavation for pipelines/cables by Manual means upto 600 mm
trench width, as per drawing and technical specifications, including setting
out, shoring, strutting, barricading, caution lights, removal of stumps and
other deleterious matter, including dressing of excavated surfaces, disposing
off or leveling the excavated earth or sorting & stacking the selected earth for
reuse in a radius of 50 m. Filling available excavated earth (excluding rock)
in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in
depth, consolidating each deposited layer by ramming and watering and lift
upto 1.5 m including cost of labour, tools, usage& other appurtenances required
to complete the work In all kinds of soils. Depth upto 1.50m | Cum | 508.2 | 508.2 | 55.0 | False | None | None | False | None | False | 27951.0 | 0 | | 2849280 | 92415 | None | 9.1.1 | Providing, laying and jointing HDPE pipes of specified grade and
conforming to IS 4984-2016 with latest ammendments and conveying
to work site including loading and unloading at both destinations and
rolling and lowering into trenches, laying true to line and jointing of
pipes and specials with electrofusion welding, giving hydraulic test
as per relevant ISS with all lead and lifts including encasing the pipe
alround to a depth of not less than 15 cms. with soft gravel or selected
earth available from the excation, testing and commissioning. The
rate is exclusive of required specials and fittings wherever necessary
like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete
(Contractor will make his own arrangements for procuring water for
testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used.
For :HDPE PE 80 PN 6.0HDPE Grade PE80-PN6.0, 63mm dia | Rmtr | 198.45 | 198.45 | 55.0 | False | None | None | False | None | False | 10914.75 | 0 | | 2849281 | 92415 | None | 1.1.1 | Supplying and fixing sheet Metal box made out of 18 SWG sheet
metal with necessary holes for cable/conduit entry as required with one
coat of primer of approved make etc 75 x 75 x 65 mm | No | 106.0 | 106.0 | 5.0 | False | None | None | False | None | False | 530.0 | 0 | | 2849282 | 92415 | None | 2.2.1 | Supplying and wiring adopting loop system in existing PVC Conduit
/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral)
& 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated
copper wire (confirming to IS-694: and latest amendments) without
control switch shall be fixed on the existing plastic sheet/ gang box,
the other end of the wires shall be terminated with sufficient loose
length in a wood/PVC round block. complete for each outlet.
Short point upto 3Mtr from tapping point to out let via switch box | No | 285.0 | 285.0 | 5.0 | False | None | None | False | None | False | 1425.0 | 0 | | 2849283 | 92415 | None | 2.2.1 | Medium point above 3Mtr upto 6Mtr from tapping point to out let via
switch box | No | 394.0 | 394.0 | 5.0 | False | None | None | False | None | False | 1970.0 | 0 | | 2849284 | 92415 | None | 2.2.2 | Long point above 6Mtr upto 10Mtr from tapping point to out let via
switch box | No | 555.0 | 555.0 | 5.0 | False | None | None | False | None | False | 2775.0 | 0 | | 2849285 | 92415 | None | 3.8 | Supplying 4mm thick plastic sheet with necessary nitches for
fixing switches, regulators etc, and fixing on existing wooden or
metal box using N.F. screws | Sqm | 0.41 | 0.41 | 1500.0 | False | None | None | False | None | False | 615.0 | 0 | | 2849286 | 92415 | None | 3.1.2 | Supplying 6A flush type socket and 6 A flush type SP switch either
surface/flush mounting in existing gang box or in 4mm thick plastic
sheet and fixing over a flush mounted wooden box and wiring using
necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 Way | Each | 147.0 | 147.0 | 25.0 | False | None | None | False | None | False | 3675.0 | 0 | | 2849287 | 92415 | None | 6.3.1 | Supplying capacitor type ceiling fan complete with down rod blades,
shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase
AC supply conforming to ISS-374- 1979 and with double ball bearing
system 48" Sweep (1200 mm) Regular mode | No | 1900.0 | 1900.0 | 4.0 | False | None | None | False | None | False | 7600.0 | 0 | | 2849288 | 92415 | None | 11.13 | Supplying and fixing of slim patty fitting, made out of CRCA Sheet
metal body with locking type holder completely wired. Excluding
Ballast & Fluorescent Tube. | No | 361.0 | 361.0 | 4.0 | False | None | None | False | None | False | 1444.0 | 0 | | 2849289 | 92415 | None | 13.1.1 | Supplying and Fixing of.mm dia class A GI pipe bracket upto 2
ms long bent at suitable angle and fixing to this bracket street light
fitting of all capacities to GI or GI or rail or RCC pole / wall using
suitable clamps, bolts, and nuts and wiring using suitable capacity
wires. Using 25mm dia G.I.Pipe | No | 978.0 | 978.0 | 1.0 | False | None | None | False | None | False | 978.0 | 0 | | 2849290 | 92415 | None | 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 1.5 mm | m | 26.0 | 26.0 | 25.0 | False | None | None | False | None | False | 650.0 | 0 | | 2849291 | 92415 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010
2.5 mm2 | m | 42.0 | 42.0 | 25.0 | False | None | None | False | None | False | 1050.0 | 0 | | 2849292 | 92415 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 4 mm2 | m | 63.0 | 63.0 | 25.0 | False | None | None | False | None | False | 1575.0 | 0 | | 2849293 | 92415 | None | P No 23 | Pre - Paid Energy Meter Single Phase, 5-30 Amps, 1.0
Accuracy Class with Key Pad Technology consumer
interface unit along with pillfer proof box
| Nos | 7170.0 | 7170.0 | 1.0 | False | None | None | False | None | False | 7170.0 | 0 | | 2849294 | 92415 | None | 12.60.1 | Supplying & Fixing Chemical earthling for grounding. Conduits, IC
cut-outs & other equipments backfill compound which is noncorrosive, thermally conductive, potential to permissible limits,
superior Fault conduction capacity, non toxic, weather resistance &
capable of achieving ohmic value less than one ohm Using 4ft. Copper bonded rod with backfill compound | Nos | 4528.0 | 4528.0 | 1.0 | False | None | None | False | None | False | 4528.0 | 0 | | 2849295 | 92415 | None | P No 2 | Supplying heavy gauge PVC conduit pipe . dia . mm thick
confirming to IS 2509 with suitable size bends, junction boxes,
adhesive paste etc , and fixing using inverted wood plugs in case of
RCC ceiling and RCC wall/ stone structure or rawl plugs in case of
brick walls and cement plastering the damaged portion using heavy
gauge saddles at an interval of 700mm using NF screws 19/20 mm dia 2 mm thick | Mtr | 69.0 | 69.0 | 40.0 | False | None | None | False | None | False | 2760.0 | 0 | | 2849296 | 92415 | None | Basic Rate | Stainless Steel Top Loading Sanitary Napkin Incinerator Machine Burning Ability 500 Kg Time | No | 24000.0 | 24000.0 | 1.0 | False | None | None | False | None | False | 24000.0 | 0 |
| | 1709144461000 | 0 | None | None | Buildings | Construction of Building Toilet Cleaning Machine Electrification and Construction of Water Tank to Hulakihal Village | 564803.53 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 2849297 | 92416 | None | 1.4 | Earth work excavation by manual means for drains, canals, waste weir, draft,
approach channels, key trenches, foundation of Buildings & bridges and such
simillar works in all kinds of soils, as per drawing and technical specifications,
including setting out, shoring, strutting, barricading, caution lights, removal
of stumps and other deleterious matter, excavated surface leveled and sides
neatly dressed disposing off the excavated stuff or sorting & stacking the
selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of
labour, tools & other appurtenaces required to complete the work.
| Cum | 254.1 | 254.1 | 6.75 | False | None | None | False | None | False | 1715.175 | 0 | | 2849298 | 92416 | None | 2.1.1 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the Mix 1:5:10 Using 40 mm nominal size graded crushed coarse aggregates work as per technical specifications | Cum | 5947.2 | 5947.2 | 1.4 | False | None | None | False | None | False | 8326.08 | 0 | | 2849299 | 92416 | None | 5.2 | Providing Coursed rubble masonry (first sort) with hard stone in
foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6948.9 | 6948.9 | 1.5 | False | None | None | False | None | False | 10423.35 | 0 | | 2849300 | 92416 | None | 5.3 | Providing Coursed rubble masonry (second sort) with hard stone in
foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6515.25 | 6515.25 | 1.2 | False | None | None | False | None | False | 7818.3 | 0 | | 2849301 | 92416 | None | 5.4 | Providing Size Stone masonry with hard stone in foundation & plinth
with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6708.45 | 6708.45 | 2.7 | False | None | None | False | None | False | 18112.815 | 0 | | 2849302 | 92416 | None | 1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of
foundations and other similar works etc. in layers not exceeding 20cm in depth,
consolidating each deposited layer by ramming and watering, lead up to 50 m
and lift upto 1.5 m | Cum | 279.3 | 279.3 | 3.6 | False | None | None | False | None | False | 1005.48 | 0 | | 2849303 | 92416 | None | 2.2.1 | Providing and laying in position Cement Concrete for all Foundation works.
The granite/trap/basalt crushed graded coarse aggregates and fine aggregates
as per relevant IS Codes machine mixed with super plasticizers laid in finished
layers, well compacted using needle vibrators, including all lead & lifts, cost
of all materials, quality confirming to the requirements of relevant IS codes,
labour, Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications | Cum | 6601.35 | 6601.35 | 1.1 | False | None | None | False | None | False | 7261.485 | 0 | | 2849304 | 92416 | None | 2.5.1 | Providing and removing centering shuttering propping etc and removal of form work for foundation appendix I Percentage on finished rate of concrete per cum | Sqm | 3960.81 | 3960.81 | 0.35 | False | None | None | False | None | False | 1386.2835 | 0 | | 2849305 | 92416 | None | 2.5.1 | Providing and removing centering shuttering propping etc and removal of form work for foundation appendix I Percentage on finished rate of concrete per cum | Sqm | 3300.68 | 3300.68 | 0.75 | False | None | None | False | None | False | 2475.51 | 0 | | 2849306 | 92416 | None | 2.11 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement
including cost of all materials, machinery, labour, cleaning, straightening,
cutting, bending, hooking, laping/welding joints, tying with binding wire / soft
annealed steel wire and other ancilary operations complete as per drawing and
technical specification | Tonne | 93929.85 | 93929.85 | 0.1 | False | None | None | False | None | False | 9392.985 | 0 | | 2849307 | 92416 | None | 6.7 | Providing Brick work with common burnt clay Non Modular bricks
of class designation 3.5 in superstructure above plinth level in all
shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand)
including cost of all materials, labour, scaffolding and usage charges of
machinery & other incidental charges complete as per the direction of
engineer incharge of work | Cum | 8621.55 | 8621.55 | 4.14 | False | None | None | False | None | False | 35693.217 | 0 | | 2849308 | 92416 | None | 8.6.1 | Providing 12 mm cement plaster with Cement mortar 1:3 (1
cement: 3 coarse sand) finished with a floating coat of neat cement
to brick masonry including rounding off corners wherever required
smooth rendering, providing and removing scaffolding, including cost
of materials, labour, curing complete as per specifications and as per
directions of Engineer-in-charge. | Sqm | 339.15 | 339.15 | 51.0 | False | None | None | False | None | False | 17296.65 | 0 | | 2849309 | 92416 | None | 8.40 | Painting with synthetic enamel paint of approved brand and
manufacture to give an even shade :Two coats on new work after
thoroughly brooming the surface to remove all dirt, dust, mortar drops
and foreign matter including preparing the surface even and sand paper
smooth, cost of materials, labour complete as per specifications and as
per directions of Engineer-in-charge. | Sqm | 120.75 | 120.75 | 51.0 | False | None | None | False | None | False | 6158.25 | 0 | | 2849310 | 92416 | None | 13.2.1 | Providing and fixing brass bib cock of approved quality | Each | 300.3 | 300.3 | 5.0 | False | None | None | False | None | False | 1501.5 | 0 | | 2849311 | 92416 | None | 1.6.1 | Earth work excavation for pipelines/cables by Manual means upto 600 mm
trench width, as per drawing and technical specifications, including setting
out, shoring, strutting, barricading, caution lights, removal of stumps and
other deleterious matter, including dressing of excavated surfaces, disposing
off or leveling the excavated earth or sorting & stacking the selected earth for
reuse in a radius of 50 m. Filling available excavated earth (excluding rock)
in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in
depth, consolidating each deposited layer by ramming and watering and lift
upto 1.5 m including cost of labour, tools, usage& other appurtenances required
to complete the work In all kinds of soils. Depth upto 1.50m | Cum | 508.2 | 508.2 | 55.0 | False | None | None | False | None | False | 27951.0 | 0 | | 2849312 | 92416 | None | 9.1.1 | Providing, laying and jointing HDPE pipes of specified grade and
conforming to IS 4984-2016 with latest ammendments and conveying
to work site including loading and unloading at both destinations and
rolling and lowering into trenches, laying true to line and jointing of
pipes and specials with electrofusion welding, giving hydraulic test
as per relevant ISS with all lead and lifts including encasing the pipe
alround to a depth of not less than 15 cms. with soft gravel or selected
earth available from the excation, testing and commissioning. The
rate is exclusive of required specials and fittings wherever necessary
like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete
(Contractor will make his own arrangements for procuring water for
testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used.
For :HDPE PE 80 PN 6.0HDPE Grade PE80-PN6.0, 63mm dia | Rmtr | 198.45 | 198.45 | 55.0 | False | None | None | False | None | False | 10914.75 | 0 | | 2849313 | 92416 | None | 15.2 | Providing and Applying PU based Elastomeric Liquid Applied PU
Waterproofing Membrane single component, cold applied, water based
acrylic PU dispersion with highly elastic and UV resistant water proofing
treatment to the Existing Roof surface/Chajjas/Sunken portion of
WC:Bathroom applied @ 1.2 l/per m2
, having tensile strength greater than
1.5N/mm2, elongation greater than 300% with solid content not less than
60% in 2 coats including surface preparation, priming the surface with
water based acrylic primer @0.1 l/m2
, and spreading 60 gsm geotextile
between two top coats completely as per specification. The finished cost
to include surface preparation, making coving at Junction, Bore Packing,
treatment of construction joints completely as per specification | Sqm | 773.85 | 773.85 | 107.1 | False | None | None | False | None | False | 82879.335 | 0 | | 2849314 | 92416 | None | 15.2 | Providing and Applying PU based Elastomeric Liquid Applied PU
Waterproofing Membrane single component, cold applied, water based
acrylic PU dispersion with highly elastic and UV resistant water proofing
treatment to the Existing Roof surface/Chajjas/Sunken portion of
WC:Bathroom applied @ 1.2 l/per m2
, having tensile strength greater than
1.5N/mm2, elongation greater than 300% with solid content not less than
60% in 2 coats including surface preparation, priming the surface with
water based acrylic primer @0.1 l/m2
, and spreading 60 gsm geotextile
between two top coats completely as per specification. The finished cost
to include surface preparation, making coving at Junction, Bore Packing,
treatment of construction joints completely as per specification | Sqm | 50.4 | 50.4 | 96.0 | False | None | None | False | None | False | 4838.4 | 0 | | 2849315 | 92416 | None | 2.1.1 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in
layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of
machinery, curing, and all the other appurtenances required to complete the
work as per technical specifications. | Cum | 5947.2 | 5947.2 | 10.8 | False | None | None | False | None | False | 64229.76 | 0 | | 2849316 | 92416 | None | 9.12.2 | Providing and laying vitrified floor tiles with thickness 9-10 mm in
different sizes with water absorption less than 0.08% and conforming to
IS: 15622, of approved make, in all colours and shades, laid on 20mm thick
cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement
slurry @ 3.3 kg/ m2 including grouting the joints with white cement and
matching pigments etc., complete Size of Tile 600x600 mm | Sqm | 1202.25 | 1202.25 | 151.2 | False | None | None | False | None | False | 181780.2 | 0 | | 2849317 | 92416 | None | Basic Rate | Stainless Steel Top Loading Sanitary Napkin Incinerator Machine Burning Ability 500 Kg | Each | 25200.0 | 25200.0 | 1.0 | False | None | None | False | None | False | 25200.0 | 0 | | 2849318 | 92416 | None | 1.1.1 | Supplying and fixing sheet Metal box made out of 18 SWG sheet
metal with necessary holes for cable/conduit entry as required with one
coat of primer of approved make etc 75 x 75 x 65 mm | No | 106.0 | 106.0 | 5.0 | False | None | None | False | None | False | 530.0 | 0 | | 2849319 | 92416 | None | 2.2.1 | Supplying and wiring adopting loop system in existing PVC Conduit
/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral)
& 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated
copper wire (confirming to IS-694: and latest amendments) without
control switch shall be fixed on the existing plastic sheet/ gang box,
the other end of the wires shall be terminated with sufficient loose
length in a wood/PVC round block. complete for each outlet.
Short point upto 3Mtr from tapping point to out let via switch box | No | 285.0 | 285.0 | 5.0 | False | None | None | False | None | False | 1425.0 | 0 | | 2849320 | 92416 | None | 2.2.1 | Medium point above 3Mtr upto 6Mtr from tapping point to out let via
switch box | No | 394.0 | 394.0 | 5.0 | False | None | None | False | None | False | 1970.0 | 0 | | 2849321 | 92416 | None | 2.2.2 | Long point above 6Mtr upto 10Mtr from tapping point to out let via
switch box | No | 555.0 | 555.0 | 5.0 | False | None | None | False | None | False | 2775.0 | 0 | | 2849322 | 92416 | None | 3.8 | Supplying 4mm thick plastic sheet with necessary nitches for
fixing switches, regulators etc, and fixing on existing wooden or
metal box using N.F. screws | Sqm | 0.41 | 0.41 | 1500.0 | False | None | None | False | None | False | 615.0 | 0 | | 2849323 | 92416 | None | 3.1.2 | Supplying 6A flush type socket and 6 A flush type SP switch either
surface/flush mounting in existing gang box or in 4mm thick plastic
sheet and fixing over a flush mounted wooden box and wiring using
necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 Way | Each | 147.0 | 147.0 | 25.0 | False | None | None | False | None | False | 3675.0 | 0 | | 2849324 | 92416 | None | 6.3.1 | Supplying capacitor type ceiling fan complete with down rod blades,
shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase
AC supply conforming to ISS-374- 1979 and with double ball bearing
system 48" Sweep (1200 mm) Regular mode | No | 1900.0 | 1900.0 | 5.0 | False | None | None | False | None | False | 9500.0 | 0 | | 2849325 | 92416 | None | 11.13 | Supplying and fixing of slim patty fitting, made out of CRCA Sheet
metal body with locking type holder completely wired. Excluding
Ballast & Fluorescent Tube. | No | 361.0 | 361.0 | 5.0 | False | None | None | False | None | False | 1805.0 | 0 | | 2849326 | 92416 | None | 13.1.1 | Supplying and Fixing of.mm dia class A GI pipe bracket upto 2
ms long bent at suitable angle and fixing to this bracket street light
fitting of all capacities to GI or GI or rail or RCC pole / wall using
suitable clamps, bolts, and nuts and wiring using suitable capacity
wires. Using 25mm dia G.I.Pipe | No | 978.0 | 978.0 | 1.0 | False | None | None | False | None | False | 978.0 | 0 | | 2849327 | 92416 | None | 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 1.5 mm | m | 26.0 | 26.0 | 40.0 | False | None | None | False | None | False | 1040.0 | 0 | | 2849328 | 92416 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010
2.5 mm2 | m | 42.0 | 42.0 | 40.0 | False | None | None | False | None | False | 1680.0 | 0 | | 2849329 | 92416 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 4 mm2 | m | 63.0 | 63.0 | 40.0 | False | None | None | False | None | False | 2520.0 | 0 | | 2849330 | 92416 | None | 1.1.1 | Supplying heavy gauge PVC conduit pipe . dia . mm thick
confirming to IS 2509 with suitable size bends, junction boxes,
adhesive paste etc , and fixing using inverted wood plugs in case of
RCC ceiling and RCC wall/ stone structure or rawl plugs in case of
brick walls and cement plastering the damaged portion using heavy
gauge saddles at an interval of 700mm using NF screws.
| Mtr | 69.0 | 69.0 | 40.0 | False | None | None | False | None | False | 2760.0 | 0 | | 2849331 | 92416 | None | P No 23 | Pre - Paid Energy Meter Single Phase, 5-30 Amps, 1.0
Accuracy Class with Card Technology | No | 7170.0 | 7170.0 | 1.0 | False | None | None | False | None | False | 7170.0 | 0 |
| | 1709144461000 | 0 | None | None | Buildings | Repairs of Electrification at Danapur Village | 16728.0 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 2849332 | 92417 | None | 1.1.1 | Supplying and fixing sheet Metal box made out of 18 SWG sheet
metal with necessary holes for cable/conduit entry as required with one
coat of primer of approved make etc 75 x 75 x 65 mm | No | 106.0 | 106.0 | 4.0 | False | None | None | False | None | False | 424.0 | 0 | | 2849333 | 92417 | None | 2.2.1 | Supplying and wiring adopting loop system in existing PVC Conduit
/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral)
& 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated
copper wire (confirming to IS-694: and latest amendments) without
control switch shall be fixed on the existing plastic sheet/ gang box,
the other end of the wires shall be terminated with sufficient loose
length in a wood/PVC round block. complete for each outlet.
Short point upto 3Mtr from tapping point to out let via switch box | No | 285.0 | 285.0 | 2.0 | False | None | None | False | None | False | 570.0 | 0 | | 2849334 | 92417 | None | 2.2.1 | Medium point above 3Mtr upto 6Mtr from tapping point to out let via
switch box | No | 394.0 | 394.0 | 2.0 | False | None | None | False | None | False | 788.0 | 0 | | 2849335 | 92417 | None | 2.2.2 | Long point above 6Mtr upto 10Mtr from tapping point to out let via
switch box | No | 555.0 | 555.0 | 2.0 | False | None | None | False | None | False | 1110.0 | 0 | | 2849336 | 92417 | None | 3.8 | Supplying 4mm thick plastic sheet with necessary nitches for
fixing switches, regulators etc, and fixing on existing wooden or
metal box using N.F. screws | Sqm | 0.41 | 0.41 | 600.0 | False | None | None | False | None | False | 246.0 | 0 | | 2849337 | 92417 | None | 3.1.2 | Supplying 6A flush type socket and 6 A flush type SP switch either
surface/flush mounting in existing gang box or in 4mm thick plastic
sheet and fixing over a flush mounted wooden box and wiring using
necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 Way | Each | 147.0 | 147.0 | 4.0 | False | None | None | False | None | False | 588.0 | 0 | | 2849338 | 92417 | None | 6.3.1 | Supplying capacitor type ceiling fan complete with down rod blades,
shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase
AC supply conforming to ISS-374- 1979 and with double ball bearing
system 48" Sweep (1200 mm) Regular mode | No | 1900.0 | 1900.0 | 2.0 | False | None | None | False | None | False | 3800.0 | 0 | | 2849339 | 92417 | None | 11.13 | Supplying and fixing of slim patty fitting, made out of CRCA Sheet
metal body with locking type holder completely wired. Excluding
Ballast & Fluorescent Tube. | No | 361.0 | 361.0 | 2.0 | False | None | None | False | None | False | 722.0 | 0 | | 2849340 | 92417 | None | 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 1.5 mm | m | 26.0 | 26.0 | 17.0 | False | None | None | False | None | False | 442.0 | 0 | | 2849341 | 92417 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010
2.5 mm2 | m | 42.0 | 42.0 | 17.0 | False | None | None | False | None | False | 714.0 | 0 | | 2849342 | 92417 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 4 mm2 | m | 63.0 | 63.0 | 17.0 | False | None | None | False | None | False | 1071.0 | 0 | | 2849343 | 92417 | None | P No 2 | Supplying heavy gauge PVC conduit pipe . dia . mm thick
confirming to IS 2509 with suitable size bends, junction boxes,
adhesive paste etc , and fixing using inverted wood plugs in case of
RCC ceiling and RCC wall/ stone structure or rawl plugs in case of
brick walls and cement plastering the damaged portion using heavy
gauge saddles at an interval of 700mm using NF screws | Mtr | 69.0 | 69.0 | 25.0 | False | None | None | False | None | False | 1725.0 | 0 | | 2849344 | 92417 | None | 12.60.1 | Supplying & Fixing Chemical earthling for grounding. Conduits, IC
cut-outs & other equipments backfill compound which is noncorrosive, thermally conductive, potential to permissible limits,
superior Fault conduction capacity, non toxic, weather resistance &
capable of achieving ohmic value less than one ohm | No | 4528.0 | 4528.0 | 1.0 | False | None | None | False | None | False | 4528.0 | 0 |
| | 1709144461000 | 0 | None | None | Buildings | Construction of Building Toilet Electrification at GHPS at Bennur Village | 1358206.32 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 2849345 | 92418 | None | 1.4 | Earth work excavation by manual means for drains, canals, waste weir, draft,
approach channels, key trenches, foundation of Buildings & bridges and such
simillar works in all kinds of soils, as per drawing and technical specifications,
including setting out, shoring, strutting, barricading, caution lights, removal
of stumps and other deleterious matter, excavated surface leveled and sides
neatly dressed disposing off the excavated stuff or sorting & stacking the
selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of
labour, tools & other appurtenaces required to complete the work.
| Cum | 254.1 | 254.1 | 41.513 | False | None | None | False | None | False | 10548.4533 | 0 | | 2849346 | 92418 | None | 2.1.1 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the Mix 1:5:10 Using 40 mm nominal size graded crushed coarse aggregates work as per technical specifications | Cum | 5947.2 | 5947.2 | 12.72 | False | None | None | False | None | False | 75648.384 | 0 | | 2849347 | 92418 | None | 5.2 | Providing Coursed rubble masonry (first sort) with hard stone in
foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6948.9 | 6948.9 | 11.31 | False | None | None | False | None | False | 78592.059 | 0 | | 2849348 | 92418 | None | 5.3 | Providing Coursed rubble masonry (second sort) with hard stone in
foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6515.25 | 6515.25 | 8.11 | False | None | None | False | None | False | 52838.6775 | 0 | | 2849349 | 92418 | None | 5.4 | Providing Size Stone masonry with hard stone in foundation & plinth
with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6708.45 | 6708.45 | 12.3 | False | None | None | False | None | False | 82513.935 | 0 | | 2849350 | 92418 | None | 1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of
foundations and other similar works etc. in layers not exceeding 20cm in depth,
consolidating each deposited layer by ramming and watering, lead up to 50 m
and lift upto 1.5 m | Cum | 279.3 | 279.3 | 45.9 | False | None | None | False | None | False | 12819.87 | 0 | | 2849351 | 92418 | None | 2.2.1 | Providing and laying in position Cement Concrete for all Foundation works.
The granite/trap/basalt crushed graded coarse aggregates and fine aggregates
as per relevant IS Codes machine mixed with super plasticizers laid in finished
layers, well compacted using needle vibrators, including all lead & lifts, cost
of all materials, quality confirming to the requirements of relevant IS codes,
labour, Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications | Cum | 6601.35 | 6601.35 | 26.33 | False | None | None | False | None | False | 173813.5455 | 0 | | 2849352 | 92418 | None | 2.5.1 | Providing and removing centering shuttering propping etc and removal of form work for foundation appendix I Percentage on finished rate of concrete per cum | Sqm | 3960.81 | 3960.81 | 5.76 | False | None | None | False | None | False | 22814.2656 | 0 | | 2849353 | 92418 | None | 2.5.1 | Providing and removing centering shuttering propping etc and removal of form work for foundation appendix I Percentage on finished rate of concrete per cum | Sqm | 3300.68 | 3300.68 | 13.1 | False | None | None | False | None | False | 43238.908 | 0 | | 2849354 | 92418 | None | 2.11 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement
including cost of all materials, machinery, labour, cleaning, straightening,
cutting, bending, hooking, laping/welding joints, tying with binding wire / soft
annealed steel wire and other ancilary operations complete as per drawing and
technical specification | Tonne | 93929.85 | 93929.85 | 2.75 | False | None | None | False | None | False | 258307.0875 | 0 | | 2849355 | 92418 | None | 6.7 | Providing Brick work with common burnt clay Non Modular bricks
of class designation 3.5 in superstructure above plinth level in all
shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand)
including cost of all materials, labour, scaffolding and usage charges of
machinery & other incidental charges complete as per the direction of
engineer incharge of work | Cum | 8621.55 | 8621.55 | 19.64 | False | None | None | False | None | False | 169327.242 | 0 | | 2849356 | 92418 | None | I No 2.5.1 | Providing and removing centering shuttering propping etc and removal of form work for foundation appendix I Percentage on finished rate of concrete per cum | Sqm | 330.07 | 330.07 | 1.73 | False | None | None | False | None | False | 571.0211 | 0 | | 2849357 | 92418 | None | 2.5.1 | Providing and removing centering shuttering propping etc and removal of form work for foundation appendix I Percentage on finished rate of concrete per cum | Sqm | 660.14 | 660.14 | 2.73 | False | None | None | False | None | False | 1802.1822 | 0 | | 2849358 | 92418 | None | 11.34B | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming
coat with approved steel primer all complete. Fixed to openings /
wooden frames with rawl plugs screws etc. | Sqm | 192.15 | 192.15 | 177.66 | False | None | None | False | None | False | 34137.369 | 0 | | 2849359 | 92418 | None | 8.6.1 | Providing 12 mm cement plaster with Cement mortar 1:3 (1
cement: 3 coarse sand) finished with a floating coat of neat cement
to brick masonry including rounding off corners wherever required
smooth rendering, providing and removing scaffolding, including cost
of materials, labour, curing complete as per specifications and as per
directions of Engineer-in-charge | Sqm | 339.15 | 339.15 | 84.78 | False | None | None | False | None | False | 28753.137 | 0 | | 2849360 | 92418 | None | 8.7 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3
coarse sand) finished with a floating coat of neat cement on the rough
side of single or half brick wall including rounding off corners wherever
required smooth rendering, providing and removing scaffolding,
including cost of materials, labour, curing complete as per specifications
and as per directions of Engineer-in-charge | Sqm | 279.3 | 279.3 | 115.38 | False | None | None | False | None | False | 32225.634 | 0 | | 2849361 | 92418 | None | 8.33.1 | Finishing with Deluxe Multi surface paint system for interiors and
exteriors using Primer as per manufacturers specifications: Two coats
applied on walls @ 1.25 ltr/10 m² over and including one coat of Special
primer applied @ 0.75 ltr /10 m² with paint of approved quality to give
an even shade, after thoroughly brooming the surface to remove all dirt,
dust, mortar drops and foreign matter including preparing the surface
even and sand paper smooth, cost of materials, labour complete as per
specifications and as per directions of Engineer-in-charge. | Sqm | 165.9 | 165.9 | 84.78 | False | None | None | False | None | False | 14065.002 | 0 | | 2849362 | 92418 | None | 8.29 | Finishing walls with textured exterior paint of required shade :New work
(Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of
exterior primer applied @ 2.20kg/10 m² to give an even shade after
thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper
smooth, cost of materials, labour complete as per specifications and as
per directions of Engineer-in-charge. | Sqm | 297.15 | 297.15 | 115.38 | False | None | None | False | None | False | 34285.167 | 0 | | 2849363 | 92418 | None | 9.12.2 | Providing and laying vitrified floor tiles in different sizes (thickness
to be specified by the manufacturer) with water absorption less than
0.08% and conforming to IS: 15622, of approved make, in all colours
and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse
sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting
the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm | Sqm | 1202.25 | 1202.25 | 57.8 | False | None | None | False | None | False | 69490.05 | 0 | | 2849364 | 92418 | None | 9.34 | Flooring with 25mm thick polished tandur blue stone slabs using cement
mortar 1:6, 25mm thick over existing cement concrete bed or top of roof
laid to line and level and jointed with cement slurry mixed with pigment
to match the shade of the slab, , including cost of materials, labour,
curing, polishing complete as per specifications.
| Sqm | 1622.25 | 1622.25 | 18.7 | False | None | None | False | None | False | 30336.075 | 0 | | 2849365 | 92418 | None | 12.12 | Providing Mathi/Nandi wood frames of doors, windows, clerestory
windows, ventilators and other frames, wrought, framed or assembled
including making plaster groves (excluding cost of cement concrete and
side clamps ), but including cost of materials, labour, usage charges
complete as per specifications. | Cum | 130412.1 | 130412.1 | 0.24 | False | None | None | False | None | False | 31298.904 | 0 | | 2849366 | 92418 | None | 12.15 | Providing and fixing in position fully panelled Honne wood shutters for
doors with stiles and rails of 40mm. thick with bottom and lock rails
180mm wide top rail and stiles 100mm wide as per drawing and panels
of 25mm thick including cost of materials, labour, usage charges
complete as per specifications. ( excluding cost of fixtures ) | Sqm | 7816.2 | 7816.2 | 8.28 | False | None | None | False | None | False | 64718.136 | 0 | | 2849367 | 92418 | None | 8.49 | Lettering with black Japan paint of approved brand and manufacture
to give an even shade including preparing the surface after thoroughly
cleaning the surface to remove all dirt, dust and foreign matter, cost of
materials, labour complete as per specifications and as per directions
of Engineer-in-charge. | Each | 4.2 | 4.2 | 7000.0 | False | None | None | False | None | False | 29400.0 | 0 | | 2849368 | 92418 | None | 88.84 | Providing Wall black boards in 12 mm thick with CM 1:3 and applied with primer and two coats of acrylic black paint including finishing etc complete | Sqm | 498.75 | 498.75 | 3.6 | False | None | None | False | None | False | 1795.5 | 0 | | 2849369 | 92418 | None | 12.80 | Providing and fixing door latch with necessary screws etc complete | Sqm | 299.25 | 299.25 | 3.6 | False | None | None | False | None | False | 1077.3 | 0 | | 2849370 | 92418 | None | 20.27.3 | Providing and fixing bright finished brass flush bolts with necessary brass screws etc cpmplete | Each | 172.2 | 172.2 | 22.0 | False | None | None | False | None | False | 3788.4 | 0 |
| | 1709144461000 | 0 | None | None | Buildings | ELECTRIFICATION at GHPS at Yaradona Village | 34247.0 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 2849371 | 92419 | None | 1.1.1 | Supplying heavy gauge PVC conduit pipe . dia . mm thick
confirming to IS 2509 with suitable size bends, junction boxes,
adhesive paste etc , and fixing using inverted wood plugs in case of
RCC ceiling and RCC wall/ stone structure or rawl plugs in case of
brick walls and cement plastering the damaged portion using heavy
gauge saddles at an interval of 700mm using NF screws | Mtr | 69.0 | 69.0 | 40.0 | False | None | None | False | None | False | 2760.0 | 0 | | 2849372 | 92419 | None | 1.1.1 | Supplying and fixing sheet Metal box made out of 18 SWG sheet
metal with necessary holes for cable/conduit entry as required with one
coat of primer of approved make etc 75 x 75 x 65 mm | No | 106.0 | 106.0 | 4.0 | False | None | None | False | None | False | 424.0 | 0 | | 2849373 | 92419 | None | 2.2.1 | Supplying and wiring adopting loop system in existing PVC Conduit
/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral)
& 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated
copper wire (confirming to IS-694: and latest amendments) without
control switch shall be fixed on the existing plastic sheet/ gang box,
the other end of the wires shall be terminated with sufficient loose
length in a wood/PVC round block. complete for each outlet.
Short point upto 3Mtr from tapping point to out let via switch box | No | 285.0 | 285.0 | 4.0 | False | None | None | False | None | False | 1140.0 | 0 | | 2849374 | 92419 | None | 2.2.1 | Medium point above 3Mtr upto 6Mtr from tapping point to out let via
switch box | No | 394.0 | 394.0 | 4.0 | False | None | None | False | None | False | 1576.0 | 0 | | 2849375 | 92419 | None | 2.2.2 | Long point above 6Mtr upto 10Mtr from tapping point to out let via
switch box | No | 555.0 | 555.0 | 4.0 | False | None | None | False | None | False | 2220.0 | 0 | | 2849376 | 92419 | None | 3.8 | Supplying 4mm thick plastic sheet with necessary nitches for
fixing switches, regulators etc, and fixing on existing wooden or
metal box using N.F. screws | Sqm | 0.41 | 0.41 | 1500.0 | False | None | None | False | None | False | 615.0 | 0 | | 2849377 | 92419 | None | 3.1.2 | Supplying 6A flush type socket and 6 A flush type SP switch either
surface/flush mounting in existing gang box or in 4mm thick plastic
sheet and fixing over a flush mounted wooden box and wiring using
necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 Way | Each | 147.0 | 147.0 | 16.0 | False | None | None | False | None | False | 2352.0 | 0 | | 2849378 | 92419 | None | 6.3.1 | Supplying capacitor type ceiling fan complete with down rod blades,
shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase
AC supply conforming to ISS-374- 1979 and with double ball bearing
system 48" Sweep (1200 mm) Regular mode | No | 1900.0 | 1900.0 | 2.0 | False | None | None | False | None | False | 3800.0 | 0 | | 2849379 | 92419 | None | 11.13 | Supplying and fixing of slim patty fitting, made out of CRCA Sheet
metal body with locking type holder completely wired. Excluding
Ballast & Fluorescent Tube. | No | 361.0 | 361.0 | 4.0 | False | None | None | False | None | False | 1444.0 | 0 | | 2849380 | 92419 | None | 13.1.1 | Supplying and Fixing of.mm dia class A GI pipe bracket upto 2
ms long bent at suitable angle and fixing to this bracket street light
fitting of all capacities to GI or GI or rail or RCC pole / wall using
suitable clamps, bolts, and nuts and wiring using suitable capacity
wires. Using 25mm dia G.I.Pipe | No | 978.0 | 978.0 | 1.0 | False | None | None | False | None | False | 978.0 | 0 | | 2849381 | 92419 | None | 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 1.5 mm | m | 26.0 | 26.0 | 40.0 | False | None | None | False | None | False | 1040.0 | 0 | | 2849382 | 92419 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010
2.5 mm2 | m | 42.0 | 42.0 | 40.0 | False | None | None | False | None | False | 1680.0 | 0 | | 2849383 | 92419 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 4 mm2 | m | 63.0 | 63.0 | 40.0 | False | None | None | False | None | False | 2520.0 | 0 | | 2849384 | 92419 | None | P No 23 | Pre - Paid Energy Meter Single Phase, 5-30 Amps, 1.0
Accuracy Class with Key Pad Technology consumer
interface unit along with pillfer proof box | Nos | 7170.0 | 7170.0 | 1.0 | False | None | None | False | None | False | 7170.0 | 0 | | 2849385 | 92419 | None | 12.60.1 | Supplying & Fixing Chemical earthling for grounding. Conduits, IC
cut-outs & other equipments backfill compound which is noncorrosive, thermally conductive, potential to permissible limits,
superior Fault conduction capacity, non toxic, weather resistance &
capable of achieving ohmic value less than one ohm Using 4ft. Copper bonded rod with backfill compound | Nos | 4528.0 | 4528.0 | 1.0 | False | None | None | False | None | False | 4528.0 | 0 |
| | 1709144461000 | 0 | None | None | Buildings | Electrification works at GHPS at Bennur Village | 12620.0 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 2849386 | 92420 | None | 1.1.1 | Supplying and fixing sheet Metal box made out of 18 SWG sheet
metal with necessary holes for cable/conduit entry as required with one
coat of primer of approved make etc 75 x 75 x 65 mm | No | 106.0 | 106.0 | 4.0 | False | None | None | False | None | False | 424.0 | 0 | | 2849387 | 92420 | None | 2.2.1 | Supplying and wiring adopting loop system in existing PVC Conduit
/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral)
& 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated
copper wire (confirming to IS-694: and latest amendments) without
control switch shall be fixed on the existing plastic sheet/ gang box,
the other end of the wires shall be terminated with sufficient loose
length in a wood/PVC round block. complete for each outlet.
Short point upto 3Mtr from tapping point to out let via switch box | No | 285.0 | 285.0 | 2.0 | False | None | None | False | None | False | 570.0 | 0 | | 2849388 | 92420 | None | 2.2.1 | Medium point above 3Mtr upto 6Mtr from tapping point to out let via
switch box | No | 394.0 | 394.0 | 2.0 | False | None | None | False | None | False | 788.0 | 0 | | 2849389 | 92420 | None | 2.2.2 | Long point above 6Mtr upto 10Mtr from tapping point to out let via
switch box | No | 555.0 | 555.0 | 2.0 | False | None | None | False | None | False | 1110.0 | 0 | | 2849390 | 92420 | None | 3.8 | Supplying 4mm thick plastic sheet with necessary nitches for
fixing switches, regulators etc, and fixing on existing wooden or
metal box using N.F. screws | Sqm | 0.41 | 0.41 | 1000.0 | False | None | None | False | None | False | 410.0 | 0 | | 2849391 | 92420 | None | 3.1.2 | Supplying 6A flush type socket and 6 A flush type SP switch either
surface/flush mounting in existing gang box or in 4mm thick plastic
sheet and fixing over a flush mounted wooden box and wiring using
necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 Way | Each | 147.0 | 147.0 | 5.0 | False | None | None | False | None | False | 735.0 | 0 | | 2849392 | 92420 | None | 6.3.1 | Supplying capacitor type ceiling fan complete with down rod blades,
shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase
AC supply conforming to ISS-374- 1979 and with double ball bearing
system 48" Sweep (1200 mm) Regular mode | No | 1900.0 | 1900.0 | 2.0 | False | None | None | False | None | False | 3800.0 | 0 | | 2849393 | 92420 | None | 11.13 | Supplying and fixing of slim patty fitting, made out of CRCA Sheet
metal body with locking type holder completely wired. Excluding
Ballast & Fluorescent Tube. | No | 361.0 | 361.0 | 2.0 | False | None | None | False | None | False | 722.0 | 0 | | 2849394 | 92420 | None | 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 1.5 mm | m | 26.0 | 26.0 | 31.0 | False | None | None | False | None | False | 806.0 | 0 | | 2849395 | 92420 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010
2.5 mm2 | m | 42.0 | 42.0 | 31.0 | False | None | None | False | None | False | 1302.0 | 0 | | 2849396 | 92420 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 4 mm2 | m | 63.0 | 63.0 | 31.0 | False | None | None | False | None | False | 1953.0 | 0 |
| | 1709144461000 | 0 | None | None | Buildings | Construction of Building Toilet Cleaning Machine Electrification and Construction of Water Tank at GHPS at Ulenour Village | 369553.49 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 2849397 | 92421 | None | 8.72.1 | Finishing walls with water proofing cement paint of required shade
:Old work (one coats applied @ 2.20 kg/10 m²) over priming
coat of primer applied @ 0.80 litrs/10 m² complete including
cost of Priming coat including preparing the surface after thoroughly
cleaning the surface to remove all dirt, dust and foreign matter, cost of
materials, labour complete as per specifications and as per directions
of Engineer-in-charge. | Sqm | 91.35 | 91.35 | 515.28 | False | None | None | False | None | False | 47070.828 | 0 | | 2849398 | 92421 | None | 19.22 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction
of Engineer-in-charge. | Cum | 50.4 | 50.4 | 62.1 | False | None | None | False | None | False | 3129.84 | 0 | | 2849399 | 92421 | None | 2.1.1 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in
layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of
machinery, curing, and all the other appurtenances required to complete the
work as per technical specifications.Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 6.21 | False | None | None | False | None | False | 36932.112 | 0 | | 2849400 | 92421 | None | 9.12.2 | Providing and laying vitrified floor tiles in different sizes (thickness
to be specified by the manufacturer) with water absorption less than
0.08% and conforming to IS: 15622, of approved make, in all colours
and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse
sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting
the joints with white cement and matching pigments etc., completeSize of Tile 600x600 mm | Sqm | 1202.25 | 1202.25 | 65.28 | False | None | None | False | None | False | 78482.88 | 0 | | 2849401 | 92421 | None | 1.4 | Earth work excavation by manual means for drains, canals, waste weir, draft,
approach channels, key trenches, foundation of Buildings & bridges and such
simillar works in all kinds of soils, as per drawing and technical specifications,
including setting out, shoring, strutting, barricading, caution lights, removal
of stumps and other deleterious matter, excavated surface leveled and sides
neatly dressed disposing off the excavated stuff or sorting & stacking the
selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of
labour, tools & other appurtenaces required to complete the work.
| Cum | 254.1 | 254.1 | 6.75 | False | None | None | False | None | False | 1715.175 | 0 | | 2849402 | 92421 | None | 2.1.1 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the Mix 1:5:10 Using 40 mm nominal size graded crushed coarse aggregates work as per technical specifications | Cum | 5947.2 | 5947.2 | 1.4 | False | None | None | False | None | False | 8326.08 | 0 | | 2849403 | 92421 | None | 5.2 | Providing Coursed rubble masonry (first sort) with hard stone in
foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6948.9 | 6948.9 | 1.5 | False | None | None | False | None | False | 10423.35 | 0 | | 2849404 | 92421 | None | 5.3 | Providing Coursed rubble masonry (second sort) with hard stone in
foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6515.25 | 6515.25 | 1.2 | False | None | None | False | None | False | 7818.3 | 0 | | 2849405 | 92421 | None | 5.4 | Providing Size Stone masonry with hard stone in foundation & plinth
with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6708.45 | 6708.45 | 2.7 | False | None | None | False | None | False | 18112.815 | 0 | | 2849406 | 92421 | None | 1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of
foundations and other similar works etc. in layers not exceeding 20cm in depth,
consolidating each deposited layer by ramming and watering, lead up to 50 m
and lift upto 1.5 m | Cum | 279.3 | 279.3 | 3.6 | False | None | None | False | None | False | 1005.48 | 0 | | 2849407 | 92421 | None | 2.2.1 | Providing and laying in position Cement Concrete for all Foundation works.
The granite/trap/basalt crushed graded coarse aggregates and fine aggregates
as per relevant IS Codes machine mixed with super plasticizers laid in finished
layers, well compacted using needle vibrators, including all lead & lifts, cost
of all materials, quality confirming to the requirements of relevant IS codes,
labour, Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications | Cum | 6601.35 | 6601.35 | 1.1 | False | None | None | False | None | False | 7261.485 | 0 | | 2849408 | 92421 | None | 2.5.1 | Providing and removing centering shuttering propping etc and removal of form work for foundation appendix I Percentage on finished rate of concrete per cum | Sqm | 3960.81 | 3960.81 | 0.35 | False | None | None | False | None | False | 1386.2835 | 0 | | 2849409 | 92421 | None | 2.5.1 | Providing and removing centering shuttering propping etc and removal of form work for foundation appendix I Percentage on finished rate of concrete per cum | Sqm | 3300.68 | 3300.68 | 0.75 | False | None | None | False | None | False | 2475.51 | 0 | | 2849410 | 92421 | None | 2.11 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement
including cost of all materials, machinery, labour, cleaning, straightening,
cutting, bending, hooking, laping/welding joints, tying with binding wire / soft
annealed steel wire and other ancilary operations complete as per drawing and
technical specification | Tonne | 93929.85 | 93929.85 | 0.1 | False | None | None | False | None | False | 9392.985 | 0 | | 2849411 | 92421 | None | 6.7 | Providing Brick work with common burnt clay Non Modular bricks
of class designation 3.5 in superstructure above plinth level in all
shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand)
including cost of all materials, labour, scaffolding and usage charges of
machinery & other incidental charges complete as per the direction of
engineer incharge of work | Cum | 8621.55 | 8621.55 | 4.14 | False | None | None | False | None | False | 35693.217 | 0 | | 2849412 | 92421 | None | 8.6.1 | Providing 12 mm cement plaster with Cement mortar 1:3 (1
cement: 3 coarse sand) finished with a floating coat of neat cement
to brick masonry including rounding off corners wherever required
smooth rendering, providing and removing scaffolding, including cost
of materials, labour, curing complete as per specifications and as per
directions of Engineer-in-charge. | Sqm | 339.15 | 339.15 | 51.0 | False | None | None | False | None | False | 17296.65 | 0 | | 2849413 | 92421 | None | 8.40 | Painting with synthetic enamel paint of approved brand and
manufacture to give an even shade :Two coats on new work after
thoroughly brooming the surface to remove all dirt, dust, mortar drops
and foreign matter including preparing the surface even and sand paper
smooth, cost of materials, labour complete as per specifications and as
per directions of Engineer-in-charge. | Sqm | 120.75 | 120.75 | 51.0 | False | None | None | False | None | False | 6158.25 | 0 | | 2849414 | 92421 | None | 13.2.1 | Providing and fixing brass bib cock of approved quality | Each | 300.3 | 300.3 | 5.0 | False | None | None | False | None | False | 1501.5 | 0 | | 2849415 | 92421 | None | 1.6.1 | Earth work excavation for pipelines/cables by Manual means upto 600 mm
trench width, as per drawing and technical specifications, including setting
out, shoring, strutting, barricading, caution lights, removal of stumps and
other deleterious matter, including dressing of excavated surfaces, disposing
off or leveling the excavated earth or sorting & stacking the selected earth for
reuse in a radius of 50 m. Filling available excavated earth (excluding rock)
in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in
depth, consolidating each deposited layer by ramming and watering and lift
upto 1.5 m including cost of labour, tools, usage& other appurtenances required
to complete the work In all kinds of soils. Depth upto 1.50m | Cum | 508.2 | 508.2 | 55.0 | False | None | None | False | None | False | 27951.0 | 0 | | 2849416 | 92421 | None | 9.1.1 | Providing, laying and jointing HDPE pipes of specified grade and
conforming to IS 4984-2016 with latest ammendments and conveying
to work site including loading and unloading at both destinations and
rolling and lowering into trenches, laying true to line and jointing of
pipes and specials with electrofusion welding, giving hydraulic test
as per relevant ISS with all lead and lifts including encasing the pipe
alround to a depth of not less than 15 cms. with soft gravel or selected
earth available from the excation, testing and commissioning. The
rate is exclusive of required specials and fittings wherever necessary
like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete
(Contractor will make his own arrangements for procuring water for
testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used.
For :HDPE PE 80 PN 6.0HDPE Grade PE80-PN6.0, 63mm dia | Rmtr | 198.45 | 198.45 | 55.0 | False | None | None | False | None | False | 10914.75 | 0 | | 2849417 | 92421 | None | Basic Rate | Stainless Steel Top Loading Sanitary Napkin Incinerator Machine Burning Ability 500 Kg Time | No | 24000.0 | 24000.0 | 1.0 | False | None | None | False | None | False | 24000.0 | 0 | | 2849418 | 92421 | None | 2.2.1 | Supplying and wiring adopting loop system in existing PVC Conduit
/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral)
& 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated
copper wire (confirming to IS-694: and latest amendments) without
control switch shall be fixed on the existing plastic sheet/ gang box,
the other end of the wires shall be terminated with sufficient loose
length in a wood/PVC round block. complete for each outlet.Short point upto 3Mtr from tapping point to out let via switch box | Nos | 285.0 | 285.0 | 1.0 | False | None | None | False | None | False | 285.0 | 0 | | 2849419 | 92421 | None | 2.2.1 | Medium point above 3Mtr upto 6Mtr from tapping point to out let via
switch box | Nos | 394.0 | 394.0 | 1.0 | False | None | None | False | None | False | 394.0 | 0 | | 2849420 | 92421 | None | 2.2.3 | Long point above 6Mtr upto 10Mtr from tapping point to out let via
switch box | No | 555.0 | 555.0 | 1.0 | False | None | None | False | None | False | 555.0 | 0 | | 2849421 | 92421 | None | 3.1.2 | Supplying 6A flush type socket and 6 A flush type SP switch either
surface/flush mounting in existing gang box or in 4mm thick plastic
sheet and fixing over a flush mounted wooden box and wiring using
necessary capacity wires as required as per IS 1293 and IS 3854
6A 3/5 Way | No | 147.0 | 147.0 | 4.0 | False | None | None | False | None | False | 588.0 | 0 | | 2849422 | 92421 | None | 12.60.1 | Supplying & Fixing Chemical earthling for grounding. Conduits, IC
cut-outs & other equipments backfill compound which is noncorrosive, thermally conductive, potential to permissible limits,
superior Fault conduction capacity, non toxic, weather resistance &
capable of achieving ohmic value less than one ohm Using 4ft. Copper bonded rod with backfill compound | Nos | 4528.0 | 4528.0 | 1.0 | False | None | None | False | None | False | 4528.0 | 0 | | 2849423 | 92421 | None | 6.3 | Supplying capacitor type ceiling fan complete with down rod blades,
shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase
AC supply conforming to ISS-374- 1979 and with double ball bearing
system | No | 1900.0 | 1900.0 | 2.0 | False | None | None | False | None | False | 3800.0 | 0 | | 2849424 | 92421 | None | 11.14.2 | Supplying and fixing of slim box fitting, made out of CRCA Sheet
metal body with locking type holder completely wired. Excluding
Ballast & Fluorescent Tube 1 x 4' Tube light fitting | Nos | 361.0 | 361.0 | 2.0 | False | None | None | False | None | False | 722.0 | 0 | | 2849425 | 92421 | None | 13.1.1 | Supplying and Fixing of.mm dia class A GI pipe bracket upto 2
ms long bent at suitable angle and fixing to this bracket street light
fitting of all capacities to GI or GI or rail or RCC pole / wall using
suitable clamps, bolts, and nuts and wiring using suitable capacity
wires.Using 25mm dia G.I.Pip | Nos | 978.0 | 978.0 | 1.0 | False | None | None | False | None | False | 978.0 | 0 | | 2849426 | 92421 | None | P No 6 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 1.5 mm | Mtr | 26.0 | 26.0 | 5.0 | False | None | None | False | None | False | 130.0 | 0 | | 2849427 | 92421 | None | P No 6 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 2.5 mm2 | Mtr | 42.0 | 42.0 | 5.0 | False | None | None | False | None | False | 210.0 | 0 | | 2849428 | 92421 | None | P No 6 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 4 mm | Mtr | 63.0 | 63.0 | 5.0 | False | None | None | False | None | False | 315.0 | 0 |
| | 1709144461000 | 0 | None | None | Buildings | Construction of Building Toilet Cleaning Machine Electrification and Construction of Water Tank to Somanal Village | 550938.79 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 2849429 | 92422 | None | 15.2 | Providing and Applying PU based Elastomeric Liquid Applied PU
Waterproofing Membrane single component, cold applied, water
based acrylic PU dispersion with highly elastic and UV resistant water
proofing treatment to the Existing Roof surface/Chajjas/Sunken portion
of WC:Bathroom applied @ 1.2L/per m2,having tensile strength greater
than 1.5N/mm2, elongation greater than 300% with solid content not
less than 60% in 2 coats including surface preparation, priming the
surface with water based acrylic primer @0.1 L/m2, and spreading 60
gsm geotextile between two top coats completely as per specification.
The finished cost to include surface preparation, making coving at
Junction, Bore Packing, treatment of construction joints completely as
per specification & with a 10 years warranty on product & work from
certified manufacturers as per the direction of the Engineer In charge. | Sqm | 773.85 | 773.85 | 107.1 | False | None | None | False | None | False | 82879.335 | 0 | | 2849430 | 92422 | None | 19.22 | Dismantling tile work in floors and roofs laid in cement mortar including
stacking material to the appropriate disposal area as per direction of
Engineer-in-charge.
| Cum | 50.4 | 50.4 | 107.1 | False | None | None | False | None | False | 5397.84 | 0 | | 2849431 | 92422 | None | 2.1.1 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in
layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of
machinery, curing, and all the other appurtenances required to complete the
work as per technical specifications.
Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 10.71 | False | None | None | False | None | False | 63694.512 | 0 | | 2849432 | 92422 | None | 9.12.2 | Providing and laying vitrified floor tiles in different sizes (thickness
to be specified by the manufacturer) with water absorption less than
0.08% and conforming to IS: 15622, of approved make, in all colours
and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse
sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting
the joints with white cement and matching pigments etc., complete Size of Tile 600x600 mm | Sqm | 1202.25 | 1202.25 | 112.8 | False | None | None | False | None | False | 135613.8 | 0 | | 2849433 | 92422 | None | Basic Rate | RO Water Plant for Hemodialysis 500 Ltrs/Hr Capacity Specifications Plant capacity (Ltrs/Hr) 500 Plant type Microprocessor/microcontroller controlled single stage RO water system ( Feed water TDS more than 500 PPM) System type Online ,Offline Double raw water pump ( one active and the other stand by) No Raw water feed pump capacity (LPH) 1500 Micron particle filter after activated Carbon filter for removing suspended particles more than micron size 5 Distribution of RO plant water sufficient for number of dialysis machines 5-10 Material of Booster pump (offline) Stainless Steel 316 | Each | 166950.0 | 166950.0 | 1.0 | False | None | None | False | None | False | 166950.0 | 0 | | 2849434 | 92422 | None | Basic Rate | Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. For 3 HP etc. complete. 3.00 HP - 300 LPM @ 26 m = 5 STG Outlet Dia - 2.50" | Each | 24326.4 | 24326.4 | 1.0 | False | None | None | False | None | False | 24326.4 | 0 | | 2849435 | 92422 | None | 1.6.1 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required
to complete the work. | Each | 24326.4 | 24326.4 | 1.0 | False | None | None | False | None | False | 24326.4 | 0 | | 2849436 | 92422 | None | 9.11 | Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for
testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0 | Each | 198.45 | 198.45 | 70.0 | False | None | None | False | None | False | 13891.5 | 0 | | 2849437 | 92422 | None | Basic Rate | Stainless Steel Top Loading Sanitary Napkin Incinerator Machine Burning Ability 500 Kg Time | Each | 24000.0 | 24000.0 | 1.0 | False | None | None | False | None | False | 24000.0 | 0 | | 2849438 | 92422 | None | 3.1.2 | Supplying 6A flush type socket and 6 A flush type SP switch either
surface/flush mounting in existing gang box or in 4mm thick plastic
sheet and fixing over a flush mounted wooden box and wiring using
necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 Way
| Nos | 147.0 | 147.0 | 6.0 | False | None | None | False | None | False | 882.0 | 0 | | 2849439 | 92422 | None | 6.3 | Supplying capacitor type ceiling fan complete with down rod blades,
shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase
AC supply conforming to ISS-374- 1979 and with double ball bearing
system 48" Sweep (1200 mm) Regular model | No | 1900.0 | 1900.0 | 4.0 | False | None | None | False | None | False | 7600.0 | 0 | | 2849440 | 92422 | None | 11.14.2 | Supplying and fixing of slim box fitting, made out of CRCA Sheet
metal body with locking type holder completely wired. Excluding
Ballast & Fluorescent Tube 1 x 4' Tube light fitting | No | 361.0 | 361.0 | 2.0 | False | None | None | False | None | False | 722.0 | 0 | | 2849441 | 92422 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 1.5 mm | Mtr | 26.0 | 26.0 | 5.0 | False | None | None | False | None | False | 130.0 | 0 | | 2849442 | 92422 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 2.5 mm2 | Mtr | 42.0 | 42.0 | 5.0 | False | None | None | False | None | False | 210.0 | 0 | | 2849443 | 92422 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010
4 mm2 | Mtr | 63.0 | 63.0 | 5.0 | False | None | None | False | None | False | 315.0 | 0 |
| | 1709144461000 | 0 | None | None | Buildings | Repairs of School Building and Repairs of Electrification at Baragur School | 361741.26 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 2849444 | 92423 | None | 15.2 | Providing and Applying PU based Elastomeric Liquid Applied PU
Waterproofing Membrane single component, cold applied, water
based acrylic PU dispersion with highly elastic and UV resistant water
proofing treatment to the Existing Roof surface/Chajjas/Sunken portion
of WC:Bathroom applied @ 1.2L/per m2,having tensile strength greater
than 1.5N/mm2, elongation greater than 300% with solid content not
less than 60% in 2 coats including surface preparation, priming the
surface with water based acrylic primer @0.1 L/m2, and spreading 60
gsm geotextile between two top coats completely as per specification.
The finished cost to include surface preparation, making coving at
Junction, Bore Packing, treatment of construction joints completely as
per specification & with a 10 years warranty on product & work from
certified manufacturers as per the direction of the Engineer In charge. | Sqm | 773.85 | 773.85 | 162.0 | False | None | None | False | None | False | 125363.7 | 0 | | 2849445 | 92423 | None | 8.72.1 | Finishing walls with water proofing cement paint of required shade
:Old work (one coats applied @ 2.20 kg/10 m²) over priming
coat of primer applied @ 0.80 litrs/10 m² complete including
cost of Priming coat including preparing the surface after thoroughly
cleaning the surface to remove all dirt, dust and foreign matter, cost of
materials, labour complete as per specifications and as per directions
of Engineer-in-charge.
| Sqm | 91.35 | 91.35 | 515.28 | False | None | None | False | None | False | 47070.828 | 0 | | 2849446 | 92423 | None | 19.22 | Dismantling tile work in floors and roofs laid in cement mortar including
stacking material to the appropriate disposal area as per direction of
Engineer-in-charge | Cum | 50.4 | 50.4 | 100.3 | False | None | None | False | None | False | 5055.12 | 0 | | 2849447 | 92423 | None | 2.1.2 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in
layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of
machinery, curing, and all the other appurtenances required to complete the
work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates
| Cum | 5947.2 | 5947.2 | 10.03 | False | None | None | False | None | False | 59650.416 | 0 | | 2849448 | 92423 | None | 9.12.2 | Providing and laying vitrified floor tiles in different sizes (thickness
to be specified by the manufacturer) with water absorption less than
0.08% and conforming to IS: 15622, of approved make, in all colours
and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse
sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting
the joints with white cement and matching pigments etc., complete Size of Tile 600x600 mm | Sqm | 1202.25 | 1202.25 | 103.64 | False | None | None | False | None | False | 124601.19 | 0 |
| | 1709144461000 | 0 | None | None | Buildings | Repairs of School Building and Repairs of Electrification and Steel Racks at Eliganour Villaget E | 518334.66 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 2849449 | 92424 | None | 8.33.1 | Finishing with Deluxe Multi surface paint system for interiors and
exteriors using Primer as per manufacturers specifications: Two coats
applied on walls @ 1.25 ltr/10 m² over and including one coat of Special
primer applied @ 0.75 ltr /10 m² with paint of approved quality to give
an even shade, after thoroughly brooming the surface to remove all dirt,
dust, mortar drops and foreign matter including preparing the surface
even and sand paper smooth, cost of materials, labour complete as per
specifications and as per directions of Engineer-in-charge. | Sqm | 165.9 | 165.9 | 486.0 | False | None | None | False | None | False | 80627.4 | 0 | | 2849450 | 92424 | None | 19.22 | Dismantling tile work in floors and roofs laid in cement mortar including
stacking material to the appropriate disposal area as per direction of
Engineer-in-charge. | Cum | 50.4 | 50.4 | 144.0 | False | None | None | False | None | False | 7257.6 | 0 | | 2849451 | 92424 | None | 2.1.1 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in
layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of
machinery, curing, and all the other appurtenances required to complete the
work as per technical specifications.Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 10.8 | False | None | None | False | None | False | 64229.76 | 0 | | 2849452 | 92424 | None | 9.12.2 | Providing and laying vitrified floor tiles in different sizes (thickness
to be specified by the manufacturer) with water absorption less than
0.08% and conforming to IS: 15622, of approved make, in all colours
and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse
sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting
the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm | Sqm | 1202.25 | 1202.25 | 152.4 | False | None | None | False | None | False | 183222.9 | 0 | | 2849453 | 92424 | None | 22.1 | Providing and supplying 18mm thick both sides pre laminated cement bonded wood particle board as per IS 15786:2008 of approved brand and shade with suitable full threaded steel screws etc | Sqm | 735.0 | 735.0 | 228.0 | False | None | None | False | None | False | 167580.0 | 0 | | 2849454 | 92424 | None | 1.1 | Supplying heavy gauge PVC conduit pipe . dia . mm thick
confirming to IS 2509 with suitable size bends, junction boxes,
adhesive paste etc , and fixing using inverted wood plugs in case of
RCC ceiling and RCC wall/ stone structure or rawl plugs in case of
brick walls and cement plastering the damaged portion using heavy
gauge saddles at an interval of 700mm using NF screws.
| Mtr | 69.0 | 69.0 | 20.0 | False | None | None | False | None | False | 1380.0 | 0 | | 2849455 | 92424 | None | 1.1.1 | Supplying and fixing sheet Metal box made out of 18 SWG sheet
metal with necessary holes for cable/conduit entry as required with one
coat of primer of approved make etc 75 x 75 x 65 mm | No | 106.0 | 106.0 | 2.0 | False | None | None | False | None | False | 212.0 | 0 | | 2849456 | 92424 | None | 2.2.1 | Supplying and wiring adopting loop system in existing PVC Conduit
/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral)
& 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated
copper wire (confirming to IS-694: and latest amendments) without
control switch shall be fixed on the existing plastic sheet/ gang box,
the other end of the wires shall be terminated with sufficient loose
length in a wood/PVC round block. complete for each outlet.
Short point upto 3Mtr from tapping point to out let via switch box | No | 285.0 | 285.0 | 2.0 | False | None | None | False | None | False | 570.0 | 0 | | 2849457 | 92424 | None | 2.2.1 | Medium point above 3Mtr upto 6Mtr from tapping point to out let via
switch box | No | 394.0 | 394.0 | 2.0 | False | None | None | False | None | False | 788.0 | 0 | | 2849458 | 92424 | None | 2.2.2 | Long point above 6Mtr upto 10Mtr from tapping point to out let via
switch box | No | 555.0 | 555.0 | 2.0 | False | None | None | False | None | False | 1110.0 | 0 | | 2849459 | 92424 | None | 3.8 | Supplying 4mm thick plastic sheet with necessary nitches for
fixing switches, regulators etc, and fixing on existing wooden or
metal box using N.F. screws | Sqm | 0.41 | 0.41 | 500.0 | False | None | None | False | None | False | 205.0 | 0 | | 2849460 | 92424 | None | 3.1.2 | Supplying 6A flush type socket and 6 A flush type SP switch either
surface/flush mounting in existing gang box or in 4mm thick plastic
sheet and fixing over a flush mounted wooden box and wiring using
necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 Way | Each | 147.0 | 147.0 | 5.0 | False | None | None | False | None | False | 735.0 | 0 | | 2849461 | 92424 | None | 6.3.1 | Supplying capacitor type ceiling fan complete with down rod blades,
shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase
AC supply conforming to ISS-374- 1979 and with double ball bearing
system 48" Sweep (1200 mm) Regular mode | No | 1900.0 | 1900.0 | 2.0 | False | None | None | False | None | False | 3800.0 | 0 | | 2849462 | 92424 | None | 11.13 | Supplying and fixing of slim patty fitting, made out of CRCA Sheet
metal body with locking type holder completely wired. Excluding
Ballast & Fluorescent Tube. | No | 361.0 | 361.0 | 2.0 | False | None | None | False | None | False | 722.0 | 0 | | 2849463 | 92424 | None | 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 1.5 mm | m | 26.0 | 26.0 | 45.0 | False | None | None | False | None | False | 1170.0 | 0 | | 2849464 | 92424 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010
2.5 mm2 | m | 42.0 | 42.0 | 45.0 | False | None | None | False | None | False | 1890.0 | 0 | | 2849465 | 92424 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 4 mm2 | m | 63.0 | 63.0 | 45.0 | False | None | None | False | None | False | 2835.0 | 0 |
| | 1709144461000 | 0 | None | None | Buildings | Construction of Building and Repairs of Electrification at Yaradona Village | 1535233.97 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 2849466 | 92425 | None | 1.4 | Earth work excavation by manual means for drains, canals, waste weir, draft,
approach channels, key trenches, foundation of Buildings & bridges and such
simillar works in all kinds of soils, as per drawing and technical specifications,
including setting out, shoring, strutting, barricading, caution lights, removal
of stumps and other deleterious matter, excavated surface leveled and sides
neatly dressed disposing off the excavated stuff or sorting & stacking the
selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of
labour, tools & other appurtenaces required to complete the work.
| Cum | 254.1 | 254.1 | 49.613 | False | None | None | False | None | False | 12606.6633 | 0 | | 2849467 | 92425 | None | 2.1.1 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the Mix 1:5:10 Using 40 mm nominal size graded crushed coarse aggregates work as per technical specifications | Cum | 5947.2 | 5947.2 | 15.23 | False | None | None | False | None | False | 90575.856 | 0 | | 2849468 | 92425 | None | 5.2 | Providing Coursed rubble masonry (first sort) with hard stone in
foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6948.9 | 6948.9 | 9.11 | False | None | None | False | None | False | 63304.479 | 0 | | 2849469 | 92425 | None | 5.3 | Providing Coursed rubble masonry (second sort) with hard stone in
foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6515.25 | 6515.25 | 8.54 | False | None | None | False | None | False | 55640.235 | 0 | | 2849470 | 92425 | None | 5.4 | Providing Size Stone masonry with hard stone in foundation & plinth
with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6708.45 | 6708.45 | 12.62 | False | None | None | False | None | False | 84660.639 | 0 | | 2849471 | 92425 | None | 1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of
foundations and other similar works etc. in layers not exceeding 20cm in depth,
consolidating each deposited layer by ramming and watering, lead up to 50 m
and lift upto 1.5 m | Cum | 279.3 | 279.3 | 54.06 | False | None | None | False | None | False | 15098.958 | 0 | | 2849472 | 92425 | None | 2.2.1 | Providing and laying in position Cement Concrete for all Foundation works.
The granite/trap/basalt crushed graded coarse aggregates and fine aggregates
as per relevant IS Codes machine mixed with super plasticizers laid in finished
layers, well compacted using needle vibrators, including all lead & lifts, cost
of all materials, quality confirming to the requirements of relevant IS codes,
labour, Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications | Cum | 6601.35 | 6601.35 | 29.71 | False | None | None | False | None | False | 196126.1085 | 0 | | 2849473 | 92425 | None | 2.5.1 | Providing and removing centering shuttering propping etc and removal of form work for foundation appendix I Percentage on finished rate of concrete per cum | Sqm | 3960.81 | 3960.81 | 7.25 | False | None | None | False | None | False | 28715.8725 | 0 | | 2849474 | 92425 | None | 2.5.1 | Providing and removing centering shuttering propping etc and removal of form work for foundation appendix I Percentage on finished rate of concrete per cum | Sqm | 3300.68 | 3300.68 | 13.1 | False | None | None | False | None | False | 43238.908 | 0 | | 2849475 | 92425 | None | 2.11 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement
including cost of all materials, machinery, labour, cleaning, straightening,
cutting, bending, hooking, laping/welding joints, tying with binding wire / soft
annealed steel wire and other ancilary operations complete as per drawing and
technical specification | Tonne | 93929.85 | 93929.85 | 3.14 | False | None | None | False | None | False | 294939.729 | 0 | | 2849476 | 92425 | None | 6.7 | Providing Brick work with common burnt clay Non Modular bricks
of class designation 3.5 in superstructure above plinth level in all
shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand)
including cost of all materials, labour, scaffolding and usage charges of
machinery & other incidental charges complete as per the direction of
engineer incharge of work | Cum | 8621.55 | 8621.55 | 22.1 | False | None | None | False | None | False | 190536.255 | 0 | | 2849477 | 92425 | None | 8.6.1 | Providing 12 mm cement plaster with Cement mortar 1:3 (1
cement: 3 coarse sand) finished with a floating coat of neat cement
to brick masonry including rounding off corners wherever required
smooth rendering, providing and removing scaffolding, including cost
of materials, labour, curing complete as per specifications and as per
directions of Engineer-in-charge. | Sqm | 339.15 | 339.15 | 95.38 | False | None | None | False | None | False | 32348.127 | 0 | | 2849478 | 92425 | None | 2.5.1 | Providing and removing centering shuttering propping etc and removal of form work for foundation appendix I Percentage on finished rate of concrete per cum | Sqm | 330.07 | 330.07 | 2.3 | False | None | None | False | None | False | 759.161 | 0 | | 2849479 | 92425 | None | 2.5.1 | Providing and removing centering shuttering propping etc and removal of form work for foundation appendix I Percentage on finished rate of concrete per cum | Sqm | 660.14 | 660.14 | 3.64 | False | None | None | False | None | False | 2402.9096 | 0 | | 2849480 | 92425 | None | 8.7 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3
coarse sand) finished with a floating coat of neat cement on the rough
side of single or half brick wall including rounding off corners wherever
required smooth rendering, providing and removing scaffolding,
including cost of materials, labour, curing complete as per specifications
and as per directions of Engineer-in-charge | Sqm | 279.3 | 279.3 | 129.98 | False | None | None | False | None | False | 36303.414 | 0 | | 2849481 | 92425 | None | 8.33.1 | Finishing with Deluxe Multi surface paint system for interiors and
exteriors using Primer as per manufacturers specifications: Two coats
applied on walls @ 1.25 ltr/10 m² over and including one coat of Special
primer applied @ 0.75 ltr /10 m² with paint of approved quality to give
an even shade, after thoroughly brooming the surface to remove all dirt,
dust, mortar drops and foreign matter including preparing the surface
even and sand paper smooth, cost of materials, labour complete as per
specifications and as per directions of Engineer-in-charge. | Sqm | 165.9 | 165.9 | 95.38 | False | None | None | False | None | False | 15823.542 | 0 | | 2849482 | 92425 | None | 8.29 | Finishing walls with textured exterior paint of required shade :New work
(Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of
exterior primer applied @ 2.20kg/10 m² to give an even shade after
thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper
smooth, cost of materials, labour complete as per specifications and as
per directions of Engineer-in-charge. | Sqm | 297.15 | 297.15 | 129.98 | False | None | None | False | None | False | 38623.557 | 0 | | 2849483 | 92425 | None | 9.12.2 | Providing and laying vitrified floor tiles in different sizes (thickness
to be specified by the manufacturer) with water absorption less than
0.08% and conforming to IS: 15622, of approved make, in all colours
and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse
sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting
the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm | Sqm | 1202.25 | 1202.25 | 74.86 | False | None | None | False | None | False | 90000.435 | 0 | | 2849484 | 92425 | None | 9.34 | Flooring with 25mm thick polished tandur blue stone slabs using cement
mortar 1:6, 25mm thick over existing cement concrete bed or top of roof
laid to line and level and jointed with cement slurry mixed with pigment
to match the shade of the slab, , including cost of materials, labour,
curing, polishing complete as per specifications. | Sqm | 1622.25 | 1622.25 | 23.1 | False | None | None | False | None | False | 37473.975 | 0 | | 2849485 | 92425 | None | 12.12 | Providing Mathi/Nandi wood frames of doors, windows, clerestory
windows, ventilators and other frames, wrought, framed or assembled
including making plaster groves (excluding cost of cement concrete and
side clamps ), but including cost of materials, labour, usage charges
complete as per specifications. | Cum | 130412.1 | 130412.1 | 0.29 | False | None | None | False | None | False | 37819.509 | 0 | | 2849486 | 92425 | None | 12.15 | Providing and fixing in position fully panelled Honne wood shutters for
doors with stiles and rails of 40mm. thick with bottom and lock rails
180mm wide top rail and stiles 100mm wide as per drawing and panels
of 25mm thick including cost of materials, labour, usage charges
complete as per specifications. ( excluding cost of fixtures ) | Sqm | 7816.2 | 7816.2 | 9.72 | False | None | None | False | None | False | 75973.464 | 0 | | 2849487 | 92425 | None | 8.49 | Lettering with black Japan paint of approved brand and manufacture
to give an even shade including preparing the surface after thoroughly
cleaning the surface to remove all dirt, dust and foreign matter, cost of
materials, labour complete as per specifications and as per directions
of Engineer-in-charge. | No | 4.2 | 4.2 | 7000.0 | False | None | None | False | None | False | 29400.0 | 0 | | 2849488 | 92425 | None | 88.84 | Providing Wall black boards in 12 mm thick with CM 1:3 and applied with primer and two coats of acrylic emulison black paint including finishing etc complete | Sqm | 498.75 | 498.75 | 3.6 | False | None | None | False | None | False | 1795.5 | 0 | | 2849489 | 92425 | None | 12.80 | Providing and fixing door latch with necessary screws etc complete | Each | 299.25 | 299.25 | 1.0 | False | None | None | False | None | False | 299.25 | 0 | | 2849490 | 92425 | None | 20.27.3 | Providing and fixing bright finished brass flush bolts with necessary
brass screws etc. complete 100 mm | Each | 172.2 | 172.2 | 22.0 | False | None | None | False | None | False | 3788.4 | 0 | | 2849491 | 92425 | None | 1.1.1 | Supplying heavy gauge PVC conduit pipe . dia . mm thick
confirming to IS 2509 with suitable size bends, junction boxes,
adhesive paste etc , and fixing using inverted wood plugs in case of
RCC ceiling and RCC wall/ stone structure or rawl plugs in case of
brick walls and cement plastering the damaged portion using heavy
gauge saddles at an interval of 700mm using NF screws | Mtr | 69.0 | 69.0 | 40.0 | False | None | None | False | None | False | 2760.0 | 0 | | 2849492 | 92425 | None | 1.1.1 | Supplying and fixing sheet Metal box made out of 18 SWG sheet
metal with necessary holes for cable/conduit entry as required with one
coat of primer of approved make etc 75 x 75 x 65 mm | No | 106.0 | 106.0 | 4.0 | False | None | None | False | None | False | 424.0 | 0 | | 2849493 | 92425 | None | 2.2.1 | Supplying and wiring adopting loop system in existing PVC Conduit
/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral)
& 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated
copper wire (confirming to IS-694: and latest amendments) without
control switch shall be fixed on the existing plastic sheet/ gang box,
the other end of the wires shall be terminated with sufficient loose
length in a wood/PVC round block. complete for each outlet.
Short point upto 3Mtr from tapping point to out let via switch box | No | 285.0 | 285.0 | 4.0 | False | None | None | False | None | False | 1140.0 | 0 | | 2849494 | 92425 | None | 2.2.1 | Medium point above 3Mtr upto 6Mtr from tapping point to out let via
switch box | No | 394.0 | 394.0 | 4.0 | False | None | None | False | None | False | 1576.0 | 0 | | 2849495 | 92425 | None | 2.2.2 | Long point above 6Mtr upto 10Mtr from tapping point to out let via
switch box | No | 555.0 | 555.0 | 4.0 | False | None | None | False | None | False | 2220.0 | 0 | | 2849496 | 92425 | None | 3.8 | Supplying 4mm thick plastic sheet with necessary nitches for
fixing switches, regulators etc, and fixing on existing wooden or
metal box using N.F. screws | Sqm | 0.41 | 0.41 | 1500.0 | False | None | None | False | None | False | 615.0 | 0 | | 2849497 | 92425 | None | 3.1.2 | Supplying 6A flush type socket and 6 A flush type SP switch either
surface/flush mounting in existing gang box or in 4mm thick plastic
sheet and fixing over a flush mounted wooden box and wiring using
necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 Way | Each | 147.0 | 147.0 | 16.0 | False | None | None | False | None | False | 2352.0 | 0 | | 2849498 | 92425 | None | 6.3.1 | Supplying capacitor type ceiling fan complete with down rod blades,
shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase
AC supply conforming to ISS-374- 1979 and with double ball bearing
system 48" Sweep (1200 mm) Regular mode | No | 1900.0 | 1900.0 | 6.0 | False | None | None | False | None | False | 11400.0 | 0 | | 2849499 | 92425 | None | 11.13 | Supplying and fixing of slim patty fitting, made out of CRCA Sheet
metal body with locking type holder completely wired. Excluding
Ballast & Fluorescent Tube. | No | 361.0 | 361.0 | 4.0 | False | None | None | False | None | False | 1444.0 | 0 | | 2849500 | 92425 | None | 13.1.1 | Supplying and Fixing of.mm dia class A GI pipe bracket upto 2
ms long bent at suitable angle and fixing to this bracket street light
fitting of all capacities to GI or GI or rail or RCC pole / wall using
suitable clamps, bolts, and nuts and wiring using suitable capacity
wires. Using 25mm dia G.I.Pipe | No | 978.0 | 978.0 | 1.0 | False | None | None | False | None | False | 978.0 | 0 | | 2849501 | 92425 | None | 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 1.5 mm | m | 26.0 | 26.0 | 40.0 | False | None | None | False | None | False | 1040.0 | 0 | | 2849502 | 92425 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010
2.5 mm2 | m | 42.0 | 42.0 | 42.0 | False | None | None | False | None | False | 1764.0 | 0 | | 2849503 | 92425 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 4 mm2 | m | 63.0 | 63.0 | 40.0 | False | None | None | False | None | False | 2520.0 | 0 | | 2849504 | 92425 | None | 12.60.1 | Supplying & Fixing Chemical earthling for grounding. Conduits, IC
cut-outs & other equipments backfill compound which is noncorrosive, thermally conductive, potential to permissible limits,
superior Fault conduction capacity, non toxic, weather resistance &
capable of achieving ohmic value less than one ohm | No | 4528.0 | 4528.0 | 1.0 | False | None | None | False | None | False | 4528.0 | 0 | | 2849505 | 92425 | None | P No 23 | Pre - Paid Energy Meter Single Phase, 5-30 Amps, 1.0
Accuracy Class with Key Pad Technology consumer
interface unit along with pillfer proof box | Nos | 7170.0 | 7170.0 | 1.0 | False | None | None | False | None | False | 7170.0 | 0 | | 2849506 | 92425 | None | 1.1.1 | Supplying heavy gauge PVC conduit pipe . dia . mm thick
confirming to IS 2509 with suitable size bends, junction boxes,
adhesive paste etc , and fixing using inverted wood plugs in case of
RCC ceiling and RCC wall/ stone structure or rawl plugs in case of
brick walls and cement plastering the damaged portion using heavy
gauge saddles at an interval of 700mm using NF screws.19/20 mm dia 2 mm thick | Mtr | 69.0 | 69.0 | 20.0 | False | None | None | False | None | False | 1380.0 | 0 | | 2849507 | 92425 | None | 1.1.1 | Supplying and fixing sheet Metal box made out of 18 SWG sheet
metal with necessary holes for cable/conduit entry as required with one
coat of primer of approved make etc 75 x 75 x 65 mm | No | 106.0 | 106.0 | 4.0 | False | None | None | False | None | False | 424.0 | 0 | | 2849508 | 92425 | None | 2.2.1 | Supplying and wiring adopting loop system in existing PVC Conduit
/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral)
& 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated
copper wire (confirming to IS-694: and latest amendments) without
control switch shall be fixed on the existing plastic sheet/ gang box,
the other end of the wires shall be terminated with sufficient loose
length in a wood/PVC round block. complete for each outlet.
Short point upto 3Mtr from tapping point to out let via switch box | No | 285.0 | 285.0 | 2.0 | False | None | None | False | None | False | 570.0 | 0 | | 2849509 | 92425 | None | 2.2.1 | Medium point above 3Mtr upto 6Mtr from tapping point to out let via
switch box | No | 394.0 | 394.0 | 2.0 | False | None | None | False | None | False | 788.0 | 0 | | 2849510 | 92425 | None | 2.2.2 | Long point above 6Mtr upto 10Mtr from tapping point to out let via
switch box | No | 555.0 | 555.0 | 2.0 | False | None | None | False | None | False | 1110.0 | 0 | | 2849511 | 92425 | None | 3.8 | Supplying 4mm thick plastic sheet with necessary nitches for
fixing switches, regulators etc, and fixing on existing wooden or
metal box using N.F. screws | Sqm | 0.41 | 0.41 | 1000.0 | False | None | None | False | None | False | 410.0 | 0 | | 2849512 | 92425 | None | 3.1.2 | Supplying 6A flush type socket and 6 A flush type SP switch either
surface/flush mounting in existing gang box or in 4mm thick plastic
sheet and fixing over a flush mounted wooden box and wiring using
necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 Way | Each | 147.0 | 147.0 | 5.0 | False | None | None | False | None | False | 735.0 | 0 | | 2849513 | 92425 | None | 6.3.1 | Supplying capacitor type ceiling fan complete with down rod blades,
shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase
AC supply conforming to ISS-374- 1979 and with double ball bearing
system 48" Sweep (1200 mm) Regular mode | No | 1900.0 | 1900.0 | 2.0 | False | None | None | False | None | False | 3800.0 | 0 | | 2849514 | 92425 | None | 11.13 | Supplying and fixing of slim patty fitting, made out of CRCA Sheet
metal body with locking type holder completely wired. Excluding
Ballast & Fluorescent Tube. | No | 361.0 | 361.0 | 2.0 | False | None | None | False | None | False | 722.0 | 0 | | 2849515 | 92425 | None | 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 1.5 mm | m | 26.0 | 26.0 | 39.0 | False | None | None | False | None | False | 1014.0 | 0 | | 2849516 | 92425 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010
2.5 mm2 | m | 42.0 | 42.0 | 39.0 | False | None | None | False | None | False | 1638.0 | 0 | | 2849517 | 92425 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 4 mm2 | m | 63.0 | 63.0 | 39.0 | False | None | None | False | None | False | 2457.0 | 0 |
| | 1709144461000 | 0 | None | None | Buildings | Repairs of 2 Rooms Building in GHPS at Kuntoji Village | 348751.98 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 2849518 | 92426 | None | 3.1 | Supplying 6A flush type socket and 6 A flush type SP switch either
surface/flush mounting in existing gang box or in 4mm thick plastic
sheet and fixing over a flush mounted wooden box and wiring using
necessary capacity wires as required as per IS 1293 and IS 3854 | No | 147.0 | 147.0 | 8.0 | False | None | None | False | None | False | 1176.0 | 0 | | 2849519 | 92426 | None | 6.3 | Supplying capacitor type ceiling fan complete with down rod blades,
shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase
AC supply conforming to ISS-374- 1979 and with double ball bearing
system. | No | 1900.0 | 1900.0 | 4.0 | False | None | None | False | None | False | 7600.0 | 0 | | 2849520 | 92426 | None | 11.14.2 | Supplying and fixing of slim box fitting, made out of CRCA Sheet
metal body with locking type holder completely wired. Excluding
Ballast & Fluorescent Tube | No | 361.0 | 361.0 | 4.0 | False | None | None | False | None | False | 1444.0 | 0 | | 2849521 | 92426 | None | 2.6 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 1.5 mm2 | Mtr | 26.0 | 26.0 | 15.0 | False | None | None | False | None | False | 390.0 | 0 | | 2849522 | 92426 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 2.5 mm | Mtr | 42.0 | 42.0 | 15.0 | False | None | None | False | None | False | 630.0 | 0 | | 2849523 | 92426 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 4 mm | Mtr | 63.0 | 63.0 | 15.0 | False | None | None | False | None | False | 945.0 | 0 | | 2849524 | 92426 | None | 15.2 | Providing and Applying PU based Elastomeric Liquid Applied PU
Waterproofing Membrane single component, cold applied, water
based acrylic PU dispersion with highly elastic and UV resistant water
proofing treatment to the Existing Roof surface/Chajjas/Sunken portion
of WC:Bathroom applied @ 1.2L/per m2,having tensile strength greater
than 1.5N/mm2, elongation greater than 300% with solid content not
less than 60% in 2 coats including surface preparation, priming the
surface with water based acrylic primer @0.1 L/m2, and spreading 60
gsm geotextile between two top coats completely as per specification.
The finished cost to include surface preparation, making coving at
Junction, Bore Packing, treatment of construction joints completely as
per specification & with a 10 years warranty on product & work from
certified manufacturers as per the direction of the Engineer In charge | Sqm | 773.85 | 773.85 | 107.1 | False | None | None | False | None | False | 82879.335 | 0 | | 2849525 | 92426 | None | 19.22 | Dismantling tile work in floors and roofs laid in cement mortar including
stacking material to the appropriate disposal area as per direction of
Engineer-in-charge.
| Cum | 50.4 | 50.4 | 96.0 | False | None | None | False | None | False | 4838.4 | 0 | | 2849526 | 92426 | None | 2.1.1 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in
layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of
machinery, curing, and all the other appurtenances required to complete the
work as per technical specifications | Cum | 5947.2 | 5947.2 | 11.52 | False | None | None | False | None | False | 68511.744 | 0 | | 2849527 | 92426 | None | 9.12.2 | Providing and laying vitrified floor tiles in different sizes (thickness
to be specified by the manufacturer) with water absorption less than
0.08% and conforming to IS: 15622, of approved make, in all colours
and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse
sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting
the joints with white cement and matching pigments etc., complete | Sqm | 1202.25 | 1202.25 | 150.0 | False | None | None | False | None | False | 180337.5 | 0 |
| | 1709144461000 | 0 | None | None | Buildings | Repairs of 5 Rooms Construction of Boys and Ladies Toilet at PU College in Karatagi | 1512930.82 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 2849528 | 92427 | None | 2.2.1 | Providing and laying in position Cement Concrete for all Foundation works.
The granite/trap/basalt crushed graded coarse aggregates and fine aggregates
as per relevant IS Codes machine mixed with super plasticizers laid in finished
layers, well compacted using needle vibrators, including all lead & lifts, cost
of all materials, quality confirming to the requirements of relevant IS codes,
labour, Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6601.35 | 6601.35 | 32.59 | False | None | None | False | None | False | 215137.9965 | 0 | | 2849529 | 92427 | None | 19.2.1 | Demolishing cement concrete manually/ by mechanical means including
disposal of material to the appropriate disposal area as per direction
of Engineer-in-charge | Cum | 1746.15 | 1746.15 | 25.0 | False | None | None | False | None | False | 43653.75 | 0 | | 2849530 | 92427 | None | 2.5.1 | Providing and removing centering, shuttering, strutting, propping etc.and removal of form work for Foundation, Appendix I Percentage on finished rate of Concrete Per Cum PWD SR 2023-24,P No.111, (Vol-1) | Sqm | 3960.81 | 3960.81 | 7.59 | False | None | None | False | None | False | 30062.5479 | 0 | | 2849531 | 92427 | None | 2.5.1 | Providing and removing centering, shuttering, strutting, propping etc.and removal of form work for Foundation, Appendix I Percentage on finished rate of Concrete Per Cum PWD SR 2023-24,P No.111, (Vol-1) | Sqm | 3300.68 | 3300.68 | 25.0 | False | None | None | False | None | False | 82517.0 | 0 | | 2849532 | 92427 | None | 2.11.a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement
including cost of all materials, machinery, labour, cleaning, straightening,
cutting, bending, hooking, laping/welding joints, tying with binding wire / soft
annealed steel wire and other ancilary operations complete as per drawing and
technical specification. | Tonne | 93929.85 | 93929.85 | 3.41 | False | None | None | False | None | False | 320300.7885 | 0 | | 2849533 | 92427 | None | 8.6.1 | Providing 12 mm cement plaster with Cement mortar 1:3 (1
cement: 3 coarse sand) finished with a floating coat of neat cement
to brick masonry including rounding off corners wherever required
smooth rendering, providing and removing scaffolding, including cost
of materials, labour, curing complete as per specifications and as per
directions of Engineer-in-charge. | Sqm | 339.15 | 339.15 | 200.0 | False | None | None | False | None | False | 67830.0 | 0 | | 2849534 | 92427 | None | 12.12 | Providing Mathi/Nandi wood frames of doors, windows, clerestory
windows, ventilators and other frames, wrought, framed or assembled
including making plaster groves (excluding cost of cement concrete and
side clamps ), but including cost of materials, labour, usage charges
complete as per specifications.
| Cum | 130412.1 | 130412.1 | 0.52 | False | None | None | False | None | False | 67814.292 | 0 | | 2849535 | 92427 | None | 12.15 | Providing and fixing in position fully panelled Honne wood shutters for
doors with stiles and rails of 40mm. thick with bottom and lock rails
180mm wide top rail and stiles 100mm wide as per drawing and panels
of 25mm thick including cost of materials, labour, usag | Sqm | 7816.2 | 7816.2 | 5.04 | False | None | None | False | None | False | 39393.648 | 0 | | 2849536 | 92427 | None | 12.23 | Providing and fixing in position Honnewood fully panelled shutters for
windows with stiles and rails of 35mm. thick, 75mm wide in two
halves with panels of 25mm thick including cost of materials, labour
charges, usage charges complete as per specifications. (excluding
cost of fixtures) | Sqm | 7952.7 | 7952.7 | 13.52 | False | None | None | False | None | False | 107520.504 | 0 | | 2849537 | 92427 | None | 15.2 | Providing and Applying PU based Elastomeric Liquid Applied PU
Waterproofing Membrane single component, cold applied, water
based acrylic PU dispersion with highly elastic and UV resistant water
proofing treatment to the Existing Roof surface/Chajjas/Sunken portion
of WC:Bathroom applied @ 1.2L/per m2,having tensile strength greater
than 1.5N/mm2, elongation greater than 300% with solid content not
less than 60% in 2 coats including surface preparation, priming the
surface with water based acrylic primer @0.1 L/m2, and spreading 60
gsm geotextile between two top coats completely as per specification.
The finished cost to include surface preparation, making coving at
Junction, Bore Packing, treatment of construction joints completely as
per specification & with a 10 years warranty on product & work from
certified manufacturers as per the direction of the Engineer In charge | Sqm | 773.85 | 773.85 | 185.25 | False | None | None | False | None | False | 143355.7125 | 0 | | 2849538 | 92427 | None | 622 | Polyethylene Water Storage tank with cover and suitable locking arrangment | Ltr | 6.3 | 6.3 | 1000.0 | False | None | None | False | None | False | 6300.0 | 0 | | 2849539 | 92427 | None | 13.31.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply, including all CPVC
plain & brass threaded fittings, including fixing the pipe with clamps at
1.00 m spacing. This includes jointing of pipes & fittings with one step
CPVC solvent cement and testing of joints complete as per direction of
Engineer in Charge Internal work - Exposed on wall 25 mm nominal dia Pipes | Mtr | 333.9 | 333.9 | 60.0 | False | None | None | False | None | False | 20034.0 | 0 | | 2849540 | 92427 | None | I No 77 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6
mm angle iron and 3 mm M.S. gusset plates at the junctions and
corners, all necessary fittings complete, including applying a priming
coat of approved steel primer. Using flats 30x6mm for diagonal braces
and central cross piece including cost of materials, labour, usage charges
of machinery complete as per specifications and as per directions of the
Engineer-in-Charge. | Sqm | 4454.1 | 4454.1 | 15.75 | False | None | None | False | None | False | 70152.075 | 0 | | 2849541 | 92427 | None | Basic Rate | Stainless Steel Top Loading Sanitary Napkin Incinerator Machine Burning Ability 500 kg Time | No | 20000.0 | 20000.0 | 1.0 | False | None | None | False | None | False | 20000.0 | 0 | | 2849542 | 92427 | None | 1.1.1 | Supplying and fixing sheet Metal box made out of 18 SWG sheet
metal with necessary holes for cable/conduit entry as required with one
coat of primer of approved make etc 75 x 75 x 65 mm | No | 106.0 | 106.0 | 4.0 | False | None | None | False | None | False | 424.0 | 0 | | 2849543 | 92427 | None | 2.2.1 | Supplying and wiring adopting loop system in existing PVC Conduit
/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral)
& 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated
copper wire (confirming to IS-694: and latest amendments) without
control switch shall be fixed on the existing plastic sheet/ gang box,
the other end of the wires shall be terminated with sufficient loose
length in a wood/PVC round block. complete for each outlet.
Short point upto 3Mtr from tapping point to out let via switch box | No | 285.0 | 285.0 | 4.0 | False | None | None | False | None | False | 1140.0 | 0 | | 2849544 | 92427 | None | 2.2.1 | Medium point above 3Mtr upto 6Mtr from tapping point to out let via
switch box | No | 394.0 | 394.0 | 4.0 | False | None | None | False | None | False | 1576.0 | 0 | | 2849545 | 92427 | None | 2.2.2 | Long point above 6Mtr upto 10Mtr from tapping point to out let via
switch box | No | 555.0 | 555.0 | 4.0 | False | None | None | False | None | False | 2220.0 | 0 | | 2849546 | 92427 | None | 3.8 | Supplying 4mm thick plastic sheet with necessary nitches for
fixing switches, regulators etc, and fixing on existing wooden or
metal box using N.F. screws | Sqm | 0.41 | 0.41 | 1500.0 | False | None | None | False | None | False | 615.0 | 0 | | 2849547 | 92427 | None | 3.1.2 | Supplying 6A flush type socket and 6 A flush type SP switch either
surface/flush mounting in existing gang box or in 4mm thick plastic
sheet and fixing over a flush mounted wooden box and wiring using
necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 Way | Each | 147.0 | 147.0 | 16.0 | False | None | None | False | None | False | 2352.0 | 0 | | 2849548 | 92427 | None | 6.3.1 | Supplying capacitor type ceiling fan complete with down rod blades,
shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase
AC supply conforming to ISS-374- 1979 and with double ball bearing
system 48" Sweep (1200 mm) Regular mode | No | 1900.0 | 1900.0 | 4.0 | False | None | None | False | None | False | 7600.0 | 0 | | 2849549 | 92427 | None | 11.13 | Supplying and fixing of slim patty fitting, made out of CRCA Sheet
metal body with locking type holder completely wired. Excluding
Ballast & Fluorescent Tube. | No | 361.0 | 361.0 | 4.0 | False | None | None | False | None | False | 1444.0 | 0 | | 2849550 | 92427 | None | 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 1.5 mm | m | 26.0 | 26.0 | 40.0 | False | None | None | False | None | False | 1040.0 | 0 | | 2849551 | 92427 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010
2.5 mm2 | m | 42.0 | 42.0 | 40.0 | False | None | None | False | None | False | 1680.0 | 0 | | 2849552 | 92427 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 4 mm2 | m | 63.0 | 63.0 | 40.0 | False | None | None | False | None | False | 2520.0 | 0 | | 2849553 | 92427 | None | 13.1.1 | SupplyingandFixingof.mmdiaclassAGIpipebracketupto2mslongbentatsuitableangleandfixingtothisbracketstreetlightfittingofallcapacitiestoGIorGIorrailorRCpole/wallusingsuitableclamps,bolts,andnutsandwiringusingsuitablecapacitywires. Using 25mm dia G.I.Pipe | No | 978.0 | 978.0 | 1.0 | False | None | None | False | None | False | 978.0 | 0 | | 2849554 | 92427 | None | P No 23 | Pre - Paid Energy Meter Single Phase, 5-30 Amps, 1.0
Accuracy Class with Key Pad Technology consumer
interface unit along with pillfer proof box | No | 7170.0 | 7170.0 | 1.0 | False | None | None | False | None | False | 7170.0 | 0 | | 2849555 | 92427 | None | 1.1.1 | SupplyingheavygaugePVCconduitpipe.dia.mmthickconfirmingtoIS2509withsuitablesizebends,junctionboxes,adhesivepasteetc,andfixingusinginvertedwoodplugsincaseofRCCceilingandRCCwall/stonestructureorrawlplugsincaseofbrickwallsandcementplasteringthedamagedportionusingheavygauge saddles at an interval of 700mm using NF screws. | Mtr | 69.0 | 69.0 | 40.0 | False | None | None | False | None | False | 2760.0 | 0 | | 2849556 | 92427 | None | 2.2.1 | For bathroom room Electrification:SupplyingandwiringadoptingloopsysteminexistingPVCConduit/casingcappingusing2x1.5Sqmm(Phase&Neutral)&1x1.0sqmm(Earthwire)FRLSmultistrandPVCinsulatedcopperwire(confirmingtoIS-694:andlatestamendments)with a6AmpsflushtypeSPcontrolswitchshallbefixedontheexistingplasticsheet/gangbox,theotherendofthewiresshallbeterminatedwithsufficientlooselengthinawood/PVCroundblock.completeforeach outlet.a) Short Point using Class A. Material | One | 285.0 | 285.0 | 4.0 | False | None | None | False | None | False | 1140.0 | 0 | | 2849557 | 92427 | None | 2.1.1 | Mediumpointabove3Mtrupto6Mtrfromtappingpointtooutletviaswitch | Nos | 394.0 | 394.0 | 4.0 | False | None | None | False | None | False | 1576.0 | 0 | | 2849558 | 92427 | None | 2.2.1 | c) Long Point using Class A. Material | No | 555.0 | 555.0 | 4.0 | False | None | None | False | None | False | 2220.0 | 0 | | 2849559 | 92427 | None | 3.1.2 | Supplying6Aflushtypesocketand6AflushtypeSPswitcheithersurface/flushmountinginexistinggangboxorin4mmthickplasticsheetandfixingoveraflushmountedwoodenboxandwiringusingnecessary capacity wires as required as per IS 1293 and IS 3854 | Nos | 147.0 | 147.0 | 16.0 | False | None | None | False | None | False | 2352.0 | 0 | | 2849560 | 92427 | None | Basic Rate | Supplyingof1440rpmheavydutyexhaustfanwithbracketbladessuitable to operate on 230V 50Hz, AC Supply complete.15" Sweep (450 mm) | Each | 4446.0 | 4446.0 | 4.0 | False | None | None | False | None | False | 17784.0 | 0 | | 2849561 | 92427 | None | 11.14.2 | Supplyingandfixingofslimboxfitting,madeoutofCRCASheetmetalbodywithlockingtypeholdercompletelywired.ExcludingBallast & Fluorescent Tube. 1 x 4' Tube light fitting. | No | 361.0 | 361.0 | 6.0 | False | None | None | False | None | False | 2166.0 | 0 | | 2849562 | 92427 | None | 13.1.1 | SupplyingandFixingof.mmdiaclassAGIpipebracketupto2mslongbentatsuitableangleandfixingtothisbracketstreetlightfittingofallcapacitiestoGIorGIorrailorRCpole/wallusingsuitableclamps,bolts,andnutsandwiringusingsuitablecapacitywires. Using 25mm dia G.I.Pipe | Each | 978.0 | 978.0 | 1.0 | False | None | None | False | None | False | 978.0 | 0 | | 2849563 | 92427 | None | P NO 6 | Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010 1.5 sqmm | Mtr | 26.0 | 26.0 | 60.0 | False | None | None | False | None | False | 1560.0 | 0 | | 2849564 | 92427 | None | P No 6 | Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010 2.5 sqmm | Mtr | 42.0 | 42.0 | 60.0 | False | None | None | False | None | False | 2520.0 | 0 | | 2849565 | 92427 | None | P No 6 | Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010 4 sqmm | Mtr | 63.0 | 63.0 | 60.0 | False | None | None | False | None | False | 3780.0 | 0 | | 2849566 | 92427 | None | Basic Rate | RO Water Plant for Hemodialysis 500 Ltrs/Hr Capacity Specifications Plant capacity (Ltrs/Hr) 500 Plant type Microprocessor/microcontroller controlled single stage RO water system ( Feed water TDS more than 500 PPM) System type Online ,Offline Double raw water pump ( one active and the other stand by) No Raw water feed pump capacity (LPH) 1500 Micron particle filter after activated Carbon filter for removing suspended particles more than micron size 5 Distribution of RO plant water sufficient for number of dialysis machines 5-10 Material of Booster pump (offline) Stainless Steel 316 | No | 159000.0 | 159000.0 | 1.0 | False | None | None | False | None | False | 159000.0 | 0 | | 2849567 | 92427 | None | 13.4.2 | Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch)
suitable for bore well confirming to IS 8034-2000 specifications, to work
site with testing of as per instructions of engineer incharge of work and 0.50 HP/0.37kW - 7 STG(stage) | Each | 11397.75 | 11397.75 | 1.0 | False | None | None | False | None | False | 11397.75 | 0 | | 2849568 | 92427 | None | 1.6.1 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required | No | 508.2 | 508.2 | 55.0 | False | None | None | False | None | False | 27951.0 | 0 | | 2849569 | 92427 | None | 9.1.1 | Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for
testing) etc. com | Mtr | 198.45 | 198.45 | 55.0 | False | None | None | False | None | False | 10914.75 | 0 |
| | 1709144461000 | 0 | None | None | Buildings | Repairs of School Building and Repairs of Electrification at GHPS Danapur Village in Gangavathi Taluka | 349678.71 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 2849570 | 92428 | None | 1.1.1 | Supplying heavy gauge PVC conduit pipe . dia . mm thick
confirming to IS 2509 with suitable size bends, junction boxes,
adhesive paste etc , and fixing using inverted wood plugs in case of
RCC ceiling and RCC wall/ stone structure or rawl plugs in case of
brick walls and cement plastering the damaged portion using heavy
gauge saddles at an interval of 700mm using NF screws.19/20 mm dia 2 mm thick | Mtr | 69.0 | 69.0 | 25.0 | False | None | None | False | None | False | 1725.0 | 0 | | 2849571 | 92428 | None | 1.1.1 | Supplying and fixing sheet Metal box made out of 18 SWG sheet
metal with necessary holes for cable/conduit entry as required with one
coat of primer of approved make etc 75 x 75 x 65 mm | No | 106.0 | 106.0 | 4.0 | False | None | None | False | None | False | 424.0 | 0 | | 2849572 | 92428 | None | 2.2.1 | Supplying and wiring adopting loop system in existing PVC Conduit
/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral)
& 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated
copper wire (confirming to IS-694: and latest amendments) without
control switch shall be fixed on the existing plastic sheet/ gang box,
the other end of the wires shall be terminated with sufficient loose
length in a wood/PVC round block. complete for each outlet.
Short point upto 3Mtr from tapping point to out let via switch box | No | 285.0 | 285.0 | 2.0 | False | None | None | False | None | False | 570.0 | 0 | | 2849573 | 92428 | None | 2.2.1 | Medium point above 3Mtr upto 6Mtr from tapping point to out let via
switch box | No | 394.0 | 394.0 | 2.0 | False | None | None | False | None | False | 788.0 | 0 | | 2849574 | 92428 | None | 2.2.2 | Long point above 6Mtr upto 10Mtr from tapping point to out let via
switch box | No | 555.0 | 555.0 | 2.0 | False | None | None | False | None | False | 1110.0 | 0 | | 2849575 | 92428 | None | 3.8 | Supplying 4mm thick plastic sheet with necessary nitches for
fixing switches, regulators etc, and fixing on existing wooden or
metal box using N.F. screws | Sqm | 0.41 | 0.41 | 600.0 | False | None | None | False | None | False | 246.0 | 0 | | 2849576 | 92428 | None | 3.1.2 | Supplying 6A flush type socket and 6 A flush type SP switch either
surface/flush mounting in existing gang box or in 4mm thick plastic
sheet and fixing over a flush mounted wooden box and wiring using
necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 Way | Each | 147.0 | 147.0 | 4.0 | False | None | None | False | None | False | 588.0 | 0 | | 2849577 | 92428 | None | 6.3.1 | Supplying capacitor type ceiling fan complete with down rod blades,
shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase
AC supply conforming to ISS-374- 1979 and with double ball bearing
system 48" Sweep (1200 mm) Regular mode | No | 1900.0 | 1900.0 | 2.0 | False | None | None | False | None | False | 3800.0 | 0 | | 2849578 | 92428 | None | 11.13 | Supplying and fixing of slim patty fitting, made out of CRCA Sheet
metal body with locking type holder completely wired. Excluding
Ballast & Fluorescent Tube. | No | 361.0 | 361.0 | 2.0 | False | None | None | False | None | False | 722.0 | 0 | | 2849579 | 92428 | None | 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 1.5 mm | m | 26.0 | 26.0 | 13.0 | False | None | None | False | None | False | 338.0 | 0 | | 2849580 | 92428 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010
2.5 mm2 | m | 42.0 | 42.0 | 13.0 | False | None | None | False | None | False | 546.0 | 0 | | 2849581 | 92428 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 4 mm2 | m | 63.0 | 63.0 | 13.0 | False | None | None | False | None | False | 819.0 | 0 | | 2849582 | 92428 | None | 12.60.1 | Supplying & Fixing Chemical earthling for grounding. Conduits, IC
cut-outs & other equipments backfill compound which is noncorrosive, thermally conductive, potential to permissible limits,
superior Fault conduction capacity, non toxic, weather resistance &
capable of achieving ohmic value less than one ohm Using 4ft. Copper bonded rod with backfill compound | Nos | 4528.0 | 4528.0 | 1.0 | False | None | None | False | None | False | 4528.0 | 0 | | 2849583 | 92428 | None | 15.2 | Providing and Applying PU based Elastomeric Liquid Applied PU
Waterproofing Membrane single component, cold applied, water
based acrylic PU dispersion with highly elastic and UV resistant water
proofing treatment to the Existing Roof surface/Chajjas/Sunken portion
of WC:Bathroom applied @ 1.2L/per m2,having tensile strength greater
than 1.5N/mm2, elongation greater than 300% with solid content not
less than 60% in 2 coats including surface preparation, priming the
surface with water based acrylic primer @0.1 L/m2, and spreading 60
gsm geotextile between two top coats completely as per specification.
The finished cost to include surface preparation, making coving at
Junction, Bore Packing, treatment of construction joints completely as
per specification & with a 10 years warranty on product & work from
certified manufacturers as per the direction of the Engineer In charge. | Sqm | 773.85 | 773.85 | 135.0 | False | None | None | False | None | False | 104469.75 | 0 | | 2849584 | 92428 | None | 8.72.1 | Finishing walls with water proofing cement paint of required shade
:Old work (one coats applied @ 2.20 kg/10 m²) over priming
coat of primer applied @ 0.80 litrs/10 m² complete including
cost of Priming coat including preparing the surface after thoroughly
cleaning the surface to remove all dirt, dust and foreign matter, cost of
materials, labour comp | Sqm | 91.35 | 91.35 | 442.2 | False | None | None | False | None | False | 40394.97 | 0 | | 2849585 | 92428 | None | 19.22 | Dismantling tile work in floors and roofs laid in cement mortar including
stacking material to the appropriate disposal area as per direction of
Engineer-in-charge. | Cum | 50.4 | 50.4 | 98.4 | False | None | None | False | None | False | 4959.36 | 0 | | 2849586 | 92428 | None | 2.1.1 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in
layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the Mix 1:5:10 Using 40 mm nominal size graded crushed coarse aggregates work as per technical specifications | Cum | 5947.2 | 5947.2 | 9.84 | False | None | None | False | None | False | 58520.448 | 0 | | 2849587 | 92428 | None | 9.12.2 | Providing and laying vitrified floor tiles in different sizes (thickness
to be specified by the manufacturer) with water absorption less than
0.08% and conforming to IS: 15622, of approved make, in all colours
and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse
sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting
the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm | Sqm | 1202.25 | 1202.25 | 104.08 | False | None | None | False | None | False | 125130.18 | 0 |
|
|
|---|