1709254776000 | 0 | None | None | Buildings | Construction of Meeting hall in KGF Police Superintendent (SP Office) Office Premises Under Municipal Fund | 2880113.33 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2865667 | 93300 | None | code01 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications,including setting out, shoring, strutting, barricading, caution lights,including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m [PWD SR 2023-24 Vol:1 P.NO.8 I.No:1.14.1] | Cum | 105.06 | 105.06 | 207.4968 | False | None | None | False | None | False | 21799.613808 | 0 | 2865668 | 93300 | None | code02 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications,including setting out, shoring, strutting, barricading, caution lights,including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work, In ordinary/soft rock without blasting upto 1.5 m depth [PWD SR 2023-24 Vol:1 P.NO.8 I.No:1.15.1] | Cum | 373.89 | 373.89 | 51.8742 | False | None | None | False | None | False | 19395.244638 | 0 | 2865669 | 93300 | None | code03 | PCC (1:3:6) Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates [PWD SR 2023-24 Vol:I P.NO.15 I.No:2.1.3] | Cum | 6168.67 | 6168.67 | 12.414 | False | None | None | False | None | False | 76577.86938 | 0 | 2865670 | 93300 | None | code04 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) [PWD SR 2023-24 Vol:I P.NO.9 I.No:5.4] | Cum | 6580.67 | 6580.67 | 31.2426 | False | None | None | False | None | False | 205597.240542 | 0 | 2865671 | 93300 | None | code05 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications. [PWD SR 2023-24 Vol:I P.NO.7 I.No:1.10] | Cum | 164.8 | 164.8 | 29.404 | False | None | None | False | None | False | 4845.7792 | 0 | 2865672 | 93300 | None | code06 | Removal of Unserviceable Soil with Disposal up to a suitable distance as directed by the Engineer in charge of work .[PWD SR 2023-24 Vol:3 P.NO.17 I.No:3.1 ] | Cum | 87.55 | 87.55 | 62.249 | False | None | None | False | None | False | 5449.89995 | 0 | 2865673 | 93300 | None | code07 | RCC (M20) Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub-structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately).M20 Design Mix Using 20 mm nominal size gradedcrushed coarse aggregates [PWD SR 2021-22 Vol:1 P.NO.16 I.No:2.4.2] For Foundation Upto Plinth considered 8% | Cum | 7033.7 | 7033.7 | 36.027 | False | None | None | False | None | False | 253403.1099 | 0 | 2865674 | 93300 | None | code08 | RCC (M20) Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size gradedcrushed coarse aggregates [PWD SR 2021-22 Vol:1 P.NO.16 I.No:2.5.1] For Columns considered 70% | Cum | 11609.13 | 11609.13 | 11.364 | False | None | None | False | None | False | 131926.15332 | 0 | 2865675 | 93300 | None | code09 | RCC (M20) Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub-structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately).M20 Design Mix Using 20 mm nominal size gradedcrushed coarse aggregates [PWD SR 2023-24 Vol:1 P.NO.16 I.No:2.4.2] For Plinth Beam considered 50% | Cum | 9769.03 | 9769.03 | 5.502 | False | None | None | False | None | False | 53749.20306 | 0 | 2865676 | 93300 | None | code10 | RCC (M20) Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub-structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately).M20 Design Mix Using 20 mm nominal size gradedcrushed coarse aggregates [PWD SR 2023-24 Vol:1 P.NO.16 I.No:2.4.2] For Beams and Lintels considered 60% | Cum | 10420.3 | 10420.3 | 6.34 | False | None | None | False | None | False | 66064.702 | 0 | 2865677 | 93300 | None | code11 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification [PWD SR 2023-24 Vol:1 P.NO.18 I.No: 2.11a] | Tonne | 92140.71 | 92140.71 | 5.2717 | False | None | None | False | None | False | 485738.180907 | 0 | 2865678 | 93300 | None | code12 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS
2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications [PWD SR 2023-24 Vol:2 P.NO.17 I.No:6.32] | Sqm | 1349.3 | 1349.3 | 58.91 | False | None | None | False | None | False | 79487.263 | 0 | 2865679 | 93300 | None | code13 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc.complete. Electric resistance or induction butt welded tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge..[PWD SR 2023-24 Vol:2 P.NO.83 I.No: 11.16.3 ] | Kg | 125.66 | 125.66 | 4760.856 | False | None | None | False | None | False | 598249.16496 | 0 | 2865680 | 93300 | None | code14 | Providing,fabricating and fixing Profiled Poly Urethane insulated Roof(PUF Sheet) having modular density 40kg/m2 and size 1.06m width and 7.60m length sheets roof having external sheet of 0.5mm steel, bottom sheet of 0.40mm steel with powder coated finish. The precoated sheet shall be of minimum 240MPa steel conforming to IS 14246 : 1995 and shal have zinc coating with minimum 120gsm as per IS 277:1992,.The roofing system shall have suitable water proof over lapping arrangments and GRIHA ceritifed.The fasting shall be of self tapping screws of required length with PVC head along with washer pre-painted aluminium cap unit with build in seal arrangments.The entire roof shall be firmly fastened to the existng frame including all lead and lifts, loading & unloading ,usage charges of machinery and equipments, transportation charges,labour charges and all other incidental charges etc.,complete as per standard 30 mm thickness [PWD SR 2023-24 Vol:2 P.NO.38 I.No: 7.67.1] | Sqm | 2263.94 | 2263.94 | 11.9 | False | None | None | False | None | False | 26940.886 | 0 | 2865681 | 93300 | None | code15 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete Ridges plain (500 - 600mm) [PWD SR 2023-24 Vol:2 P.NO.26 I.No: 7.39.1] | m | 464.53 | 464.53 | 21.33 | False | None | None | False | None | False | 9908.4249 | 0 | 2865682 | 93300 | None | code16 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete Gutter (600 mm over all girth) [PWD SR 2023-24 Vol:2 P.NO.27 I.No: 7.39.6] | m | 1106.22 | 1106.22 | 42.66 | False | None | None | False | None | False | 47191.3452 | 0 | 2865683 | 93300 | None | code17 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. [PWD SR 2023-24 Vol:2 P.NO.41 I.No:8.3.2] | Sqm | 342.99 | 342.99 | 150.95 | False | None | None | False | None | False | 51774.3405 | 0 | 2865684 | 93300 | None | code18 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.[PWD SR 2023-24 Vol:2 P.NO.99 I.No: 12.12] | Cum | 127928.06 | 127928.06 | 0.297 | False | None | None | False | None | False | 37994.63382 | 0 | 2865685 | 93300 | None | code19 | Providing and fixing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) [PWD SR 2023-24 Vol:2 P.NO.100 I.No: 12.15] | Sqm | 7103.91 | 7103.91 | 5.04 | False | None | None | False | None | False | 35803.7064 | 0 | 2865686 | 93300 | None | code20 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermoplastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2mm. Maximum possible size 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) [PWD SR 2023-24 Vol:3 P.NO.108 I. No: 12.84 ] | Sqm | 5173.69 | 5173.69 | 79.19 | False | None | None | False | None | False | 409704.5111 | 0 | 2865687 | 93300 | None | code21 | Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm [PWD SR 2023-24 Vol:2 P.NO.60 I.No:9.12.2] | Sqm | 1179.35 | 1179.35 | 198.369 | False | None | None | False | None | False | 233946.48015 | 0 | 2865688 | 93300 | None | code22 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life)[PWD SR 2023-24 Vol:2 P.NO.46 I.No:8.33.1] | Sqm | 162.74 | 162.74 | 150.95 | False | None | None | False | None | False | 24565.603 | 0 |
|