| 2865695 | 93307 | None | Code 01 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure omprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever ecessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable aterial with all lifts and lead (Cement Concrete Grade M-15 & M-20) | Cum | 767.55 | 767.55 | 60.0 | False | None | None | False | None | False | 46053.0 | 0 |
| 2865696 | 93307 | None | Code 02 | Earth work excavation for Foundation by manual means for all Buildings, Bridges, Retaining walls, Abutment Piers and such similar works as per drawing and technical Specifications, including setting out, providing shoring & strutting,barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.(Depth exceeding 1.5m, but not exceeding 3 m)
| Cum | 208.95 | 208.95 | 30.66 | False | None | None | False | None | False | 6406.407 | 0 |
| 2865697 | 93307 | None | Code 03 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm and down size graded crushed coarseaggregates | Cum | 6014.4 | 6014.4 | 3.723 | False | None | None | False | None | False | 22391.6112 | 0 |
| 2865698 | 93307 | None | Code 04 | Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)
| Cum | 5820.15 | 5820.15 | 9.88 | False | None | None | False | None | False | 57503.082 | 0 |
| 2865699 | 93307 | None | Code 05 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5619.6 | 5619.6 | 7.9 | False | None | None | False | None | False | 44394.84 | 0 |
| 2865700 | 93307 | None | Code 06 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 6219.15 | 6219.15 | 1.8 | False | None | None | False | None | False | 11194.47 | 0 |
| 2865701 | 93307 | None | Code 07 | Appendix I Additionalities for Formwork, Centering & Scaffolding Foundation upto Plinth b. All other types | Cum | 186.57 | 186.57 | 1.8 | False | None | None | False | None | False | 335.826 | 0 |
| 2865702 | 93307 | None | Code 08 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates
| Cum | 6240.15 | 6240.15 | 1.7 | False | None | None | False | None | False | 10608.255 | 0 |
| 2865703 | 93307 | None | Code 09 | Appendix I Additionalities for Formwork, Centering & Scaffolding Columns & Piers
| Cum | 624.02 | 624.02 | 1.7 | False | None | None | False | None | False | 1060.834 | 0 |
| 2865704 | 93307 | None | Code 10 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 design mix Using 20mm nominal size graded crushed coarse aggregates | Cum | 6491.1 | 6491.1 | 3.85 | False | None | None | False | None | False | 24990.735 | 0 |
| 2865705 | 93307 | None | Code 11 | Appendix I Additionalities for Formwork, Centering & Scaffolding Beams & Lintels of Building | Cum | 1298.22 | 1298.22 | 3.83 | False | None | None | False | None | False | 4972.1826 | 0 |
| 2865706 | 93307 | None | Code 12 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 design mix Using 20mm nominal size graded crushed coarse aggregates | Cum | 6491.1 | 6491.1 | 6.69 | False | None | None | False | None | False | 43425.459 | 0 |
| 2865707 | 93307 | None | Code 12 | Appendix I Additionalities for Formwork, Centering & ScaffoldingRoof (Straight & Arched)
| Cum | 1298.22 | 1298.22 | 6.45 | False | None | None | False | None | False | 8373.519 | 0 |
| 2865708 | 93307 | None | Code 14 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings | Tonne | 76650.0 | 76650.0 | 0.825 | False | None | None | False | None | False | 63236.25 | 0 |
| 2865709 | 93307 | None | Code 15 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 7024.5 | 7024.5 | 28.67 | False | None | None | False | None | False | 201392.415 | 0 |
| 2865710 | 93307 | None | Code 16 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. | Mtr | 498.75 | 498.75 | 15.75 | False | None | None | False | None | False | 7855.3125 | 0 |
| 2865711 | 93307 | None | Code 17 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges do- with one side prelam | Sqm | 2998.8 | 2998.8 | 15.75 | False | None | None | False | None | False | 47231.1 | 0 |
| 2865712 | 93307 | None | Code 18 | Providing and fixing Structural Steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Kg | 101.85 | 101.85 | 117.18 | False | None | None | False | None | False | 11934.783 | 0 |
| 2865713 | 93307 | None | Code 19 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 6891.15 | 6891.15 | 3.15 | False | None | None | False | None | False | 21707.1225 | 0 |
| 2865714 | 93307 | None | Code 20 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/m²) including cost of materials, labour, usage charges of machinery complete as per specifications.
| Sqm | 961.8 | 961.8 | 2.88 | False | None | None | False | None | False | 2769.984 | 0 |
| 2865715 | 93307 | None | Code 21 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 207.9 | 207.9 | 137.24 | False | None | None | False | None | False | 28532.196 | 0 |
| 2865716 | 93307 | None | Code 22 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 322.35 | 322.35 | 104.81 | False | None | None | False | None | False | 33785.5035 | 0 |
| 2865717 | 93307 | None | Code 23 | Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications. | Sqm | 1251.6 | 1251.6 | 22.3 | False | None | None | False | None | False | 27910.68 | 0 |
| 2865718 | 93307 | None | Code 24 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. | Sqm | 800.1 | 800.1 | 12.98 | False | None | None | False | None | False | 10385.298 | 0 |
| 2865719 | 93307 | None | Code 25 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching
shade complete. | Sqm | 1012.2 | 1012.2 | 56.25 | False | None | None | False | None | False | 56936.25 | 0 |
| 2865720 | 93307 | None | Code 26 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 110.25 | 110.25 | 137.24 | False | None | None | False | None | False | 15130.71 | 0 |
| 2865721 | 93307 | None | Code 27 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 69.3 | 69.3 | 104.81 | False | None | None | False | None | False | 7263.333 | 0 |
| 2865722 | 93307 | None | Code 28 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 111.3 | 111.3 | 5.58 | False | None | None | False | None | False | 621.054 | 0 |
| 2865723 | 93307 | None | Code 29 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests | Each | 4458.3 | 4458.3 | 10.0 | False | None | None | False | None | False | 44583.0 | 0 |
| 2865724 | 93307 | None | Code 30 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer | Each | 2655.45 | 2655.45 | 2.0 | False | None | None | False | None | False | 5310.9 | 0 |
| 2865725 | 93307 | None | Code 31 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 1500x450 mm | Each | 1549.8 | 1549.8 | 2.0 | False | None | None | False | None | False | 3099.6 | 0 |
| 2865726 | 93307 | None | Code 32 | Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. | Each | 4057.2 | 4057.2 | 4.0 | False | None | None | False | None | False | 16228.8 | 0 |
| 2865727 | 93307 | None | Code 33 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 110mm dia., 6 kg/sqcm & class 3 | Mtr | 413.7 | 413.7 | 30.0 | False | None | None | False | None | False | 12411.0 | 0 |
| 2865728 | 93307 | None | Code 34 | Providing and fixing unplasticised PVC connection pipe with brass unions :20 mm nominal bore | No | 133.35 | 133.35 | 40.0 | False | None | None | False | None | False | 5334.0 | 0 |
| 2865729 | 93307 | None | Code 35 | Providing and fixing brss bib cock of approved quality etc. | No | 365.25 | 365.25 | 12.0 | False | None | None | False | None | False | 4383.0 | 0 |
| 2865730 | 93307 | None | Code 36 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :32 mm nominal bore | No | 605.85 | 605.85 | 2.0 | False | None | None | False | None | False | 1211.7 | 0 |
| 2865731 | 93307 | None | Code 37 | Providing and fixing brass stop cock of approved quality : 20 mm nominal bore | No | 362.25 | 362.25 | 2.0 | False | None | None | False | None | False | 724.5 | 0 |
| 2865732 | 93307 | None | Code 38 | Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately. | l | 8.93 | 8.93 | 1000.0 | False | None | None | False | None | False | 8930.0 | 0 |
| 2865733 | 93307 | None | Code 39 | Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25 mm dia 2 mm thick | Mtr | 82.95 | 82.95 | 30.0 | False | None | None | False | None | False | 2488.5 | 0 |
| 2865734 | 93307 | None | Code 40 | Supplying and fixing PVC/metal conduit Deep junction box 25 mm deep Junction box
| Each | 58.8 | 58.8 | 4.0 | False | None | None | False | None | False | 235.2 | 0 |
| 2865735 | 93307 | None | Code 41 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A Short point upto 3m from tapping point to out let via switch | Point | 299.25 | 299.25 | 2.0 | False | None | None | False | None | False | 598.5 | 0 |
| 2865736 | 93307 | None | Code 42 | Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments.1x3x4 Sqm Common SR WS&SW 2023-24 Vol-5 It. No. 13.22.3 Pg. No. 154 | Mtr | 194.25 | 194.25 | 300.0 | False | None | None | False | None | False | 58275.0 | 0 |
| 2865737 | 93307 | None | Code 43 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A Long point above 6m upto 10m from tapping point to out let via switch | Point | 598.5 | 598.5 | 4.0 | False | None | None | False | None | False | 2394.0 | 0 |
| 2865738 | 93307 | None | Code 44 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of 6C x 1.5 mm2 | Mtr | 127.05 | 127.05 | 40.0 | False | None | None | False | None | False | 5082.0 | 0 |
| 2865739 | 93307 | None | Code 45 | Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 6A 2 Way | Each | 134.4 | 134.4 | 3.0 | False | None | None | False | None | False | 403.2 | 0 |
| 2865740 | 93307 | None | Code 46 | Supplying and mounting 2 Nos. of 2Way 6 A flush type switches either surface/flush mounted on existing gang box or in 4mm thick plastic sheet and mounted on a flush mounted wooden box and wiring as per IS 1293 | Each | 186.9 | 186.9 | 3.0 | False | None | None | False | None | False | 560.7 | 0 |
| 2865741 | 93307 | None | Code 47 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.1-3 Way | Each | 108.15 | 108.15 | 3.0 | False | None | None | False | None | False | 324.45 | 0 |
| 2865742 | 93307 | None | Code 48 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 6 Way | Each | 143.85 | 143.85 | 3.0 | False | None | None | False | None | False | 431.55 | 0 |
| 2865743 | 93307 | None | Code 49 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles.Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.48" Sweep (1200 mm) Regular model | Each | 3133.2 | 3133.2 | 1.0 | False | None | None | False | None | False | 3133.2 | 0 |
| 2865744 | 93307 | None | Code 50 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts,nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure III - Double Door 6 Way TP & N | Each | 5187.0 | 5187.0 | 1.0 | False | None | None | False | None | False | 5187.0 | 0 |
| 2865745 | 93307 | None | Code 51 | Supplying & fixing of retrofit type - LED bulb . W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRIGreater then 70%. efficacy Greater then80 lumen per W, lifeGreater then 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF Greater then 0.95, power loss should Less then 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.18W, 6500K | Each | 447.3 | 447.3 | 5.0 | False | None | None | False | None | False | 2236.5 | 0 |
| 2865746 | 93307 | None | Code 52 | Earthing: Providing and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. | Job | 3937.5 | 3937.5 | 1.0 | False | None | None | False | None | False | 3937.5 | 0 |