| tenderSubEstimateList | | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
|---|
| 1709186505000 | 1 | None | None | Buildings | CIVIL WORK FOR Construction of Public Samuday Bhavan for ST People at Panchayat property no.216/1 Amate Village in Khanapur Taluka | 1149400.48 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 2854045 | 92630 | None | code01 | Earth work excavation by manual means for drains,canals, waste weir,draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.In all kinds of soils Depth upto 1.5 m with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 208.32 | 208.32 | 32.036 | False | None | None | False | None | False | 6673.73952 | 0 | | 2854046 | 92630 | None | code02 | Providing and laying in position plain cement concrete Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 6415.36 | 6415.36 | 8.061 | False | None | None | False | None | False | 51714.21696 | 0 | | 2854047 | 92630 | None | code03 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 7188.65 | 7188.65 | 8.269 | False | None | None | False | None | False | 59442.94685 | 0 | | 2854048 | 92630 | None | code04 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 11363.07 | 11363.07 | 4.287 | False | None | None | False | None | False | 48713.48109 | 0 | | 2854049 | 92630 | None | code05 | Providing and laying in position Reinforced cement concrete M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M 40 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PLINTH, LINTEL, PORCH AND SLAB BEAMS, with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 11078.14 | 11078.14 | 6.59 | False | None | None | False | None | False | 73004.9426 | 0 | | 2854050 | 92630 | None | code06 | Providing and laying in position Reinforced cement concrete M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M 40 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SLAB AND PORCH with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 10385.76 | 10385.76 | 8.25 | False | None | None | False | None | False | 85682.52 | 0 | | 2854051 | 92630 | None | code07 | Providing and laying in position Reinforced cement concrete M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M 40 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, CHAJJA with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 10039.57 | 10039.57 | 0.374 | False | None | None | False | None | False | 3754.79918 | 0 | | 2854052 | 92630 | None | code08 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Kg | 103.04 | 103.04 | 2048.8 | False | None | None | False | None | False | 211108.352 | 0 | | 2854053 | 92630 | None | code09 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 7499.52 | 7499.52 | 25.96 | False | None | None | False | None | False | 194687.5392 | 0 | | 2854054 | 92630 | None | code10 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 228.48 | 228.48 | 30.511 | False | None | None | False | None | False | 6971.15328 | 0 | | 2854055 | 92630 | None | code11 | Supplying, filling, spreading & leveling stone boulders of size range 5cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 1075.2 | 1075.2 | 5.548 | False | None | None | False | None | False | 5965.2096 | 0 | | 2854056 | 92630 | None | code12 | Providing 12 mm cement plaster with Cement mortar 1:3 (1cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 306.88 | 306.88 | 163.483 | False | None | None | False | None | False | 50169.66304 | 0 | | 2854057 | 92630 | None | code13 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Kg | 162.4 | 162.4 | 302.4 | False | None | None | False | None | False | 49109.76 | 0 | | 2854058 | 92630 | None | code14 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 343.84 | 343.84 | 130.697 | False | None | None | False | None | False | 44938.85648 | 0 | | 2854059 | 92630 | None | code15 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:3 (1 cement:3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 348.32 | 348.32 | 24.874 | False | None | None | False | None | False | 8664.11168 | 0 | | 2854060 | 92630 | None | code16 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 84385.28 | 84385.28 | 0.0548 | False | None | None | False | None | False | 4624.313344 | 0 | | 2854061 | 92630 | None | code17 | Providing and fixing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 5102.72 | 5102.72 | 2.8428 | False | None | None | False | None | False | 14506.012416 | 0 | | 2854062 | 92630 | None | code18 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm , with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 1217.44 | 1217.44 | 58.59 | False | None | None | False | None | False | 71329.8096 | 0 | | 2854063 | 92630 | None | code19 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 92.96 | 92.96 | 131.758 | False | None | None | False | None | False | 12248.22368 | 0 | | 2854064 | 92630 | None | code20 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 117.6 | 117.6 | 131.758 | False | None | None | False | None | False | 15494.7408 | 0 | | 2854065 | 92630 | None | code21 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 132.16 | 132.16 | 155.571 | False | None | None | False | None | False | 20560.26336 | 0 | | 2854066 | 92630 | None | code22 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directionsof Engineer-in-charge. with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 117.6 | 117.6 | 7.875 | False | None | None | False | None | False | 926.1 | 0 | | 2854067 | 92630 | None | code23 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 118.72 | 118.72 | 36.0 | False | None | None | False | None | False | 4273.92 | 0 | | 2854068 | 92630 | None | code24 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2 (Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame.The outer frame having a overall size of 60mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm X 58mm with GI reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2-2.5 mm. Maximum possible size 1819mm x 1819mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 7180.32 | 7180.32 | 14.4 | False | None | None | False | None | False | 103396.608 | 0 | | 2854069 | 92630 | None | code25 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete cost and conveyence of all materials with all lead and lift. etc complete with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Nos | 196.0 | 196.0 | 1.0 | False | None | None | False | None | False | 196.0 | 0 | | 2854070 | 92630 | None | code26 | Providing and fixing MS oxidised Hinges of length 125(5 Inches) mm for doors etc complete with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Nos | 182.56 | 182.56 | 3.0 | False | None | None | False | None | False | 547.68 | 0 | | 2854071 | 92630 | None | code27 | Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. with all lead and lift. etc complete with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Nos | 695.52 | 695.52 | 1.0 | False | None | None | False | None | False | 695.52 | 0 |
| | 1709186505000 | 0 | None | None | Buildings | ELECTRICAL WORK FOR Construction of Public Samuday Bhavan for ST People at Panchayat property no.216/1 Amate Village in Khanapur Taluka | 25168.0 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 2854072 | 92631 | None | code01 | Supplying heavy gauge PVC conduit pipe …….dia .......mmthick confirming to IS 2509 with suitable size bends, junctionboxes, adhesive paste etc., and fixing using inverted woodplugs in case of RCC ceiling and RCC wall / stone structureor rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an intervalof 700mm uing NF screws.19/20mm dia 2mm thick with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Mtr | 50.0 | 50.0 | 40.0 | False | None | None | False | None | False | 2000.0 | 0 | | 2854073 | 92631 | None | code02 | Supplying and flush mounting teak wooden box without frontplank, made of not less than 12mm thick wood, after duegroove cutting, Finishing with necessary cement plastering complete.10"X7"X3'' with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 77.0 | 77.0 | 2.0 | False | None | None | False | None | False | 154.0 | 0 | | 2854074 | 92631 | None | code03 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. 2.1.1 Short point upto 3Mtr from tapping point to out let via switch with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Point | 200.0 | 200.0 | 1.0 | False | None | None | False | None | False | 200.0 | 0 | | 2854075 | 92631 | None | code04 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. 2.1.2 Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Point | 275.0 | 275.0 | 2.0 | False | None | None | False | None | False | 550.0 | 0 | | 2854076 | 92631 | None | code05 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long Point above 6 Mtr upto 6 Mtr from tapping point to outlet via switches. with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Point | 400.0 | 400.0 | 1.0 | False | None | None | False | None | False | 400.0 | 0 | | 2854077 | 92631 | None | code06 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of GROUP -A...1.5 sqmm with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Mtr | 20.5 | 20.5 | 80.0 | False | None | None | False | None | False | 1640.0 | 0 | | 2854078 | 92631 | None | code07 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of GROUP -A…2.5 sqmm with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Mtr | 32.0 | 32.0 | 80.0 | False | None | None | False | None | False | 2560.0 | 0 | | 2854079 | 92631 | None | code08 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of GROUP -A…4 sqmm with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Mtr | 45.0 | 45.0 | 60.0 | False | None | None | False | None | False | 2700.0 | 0 | | 2854080 | 92631 | None | code09 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 GROUP A.. Stepped Fan Regulator. with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 290.0 | 290.0 | 1.0 | False | None | None | False | None | False | 290.0 | 0 | | 2854081 | 92631 | None | code10 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 GROUP A.. 32Amps DP switch with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 182.0 | 182.0 | 16.0 | False | None | None | False | None | False | 2912.0 | 0 | | 2854082 | 92631 | None | code11 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 GROUP A.. 6/16Amps universal socket with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 162.0 | 162.0 | 8.0 | False | None | None | False | None | False | 1296.0 | 0 | | 2854083 | 92631 | None | code12 | Supplying and fixing hylum plastic sheet 3mm thick with necessary nitches for fixing switches, regulators etc., and fixing on existing wood or metal box using N.F. screws. with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Sq CM | 0.24 | 0.24 | 500.0 | False | None | None | False | None | False | 120.0 | 0 | | 2854084 | 92631 | None | code13 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898... 6-32Amps SP with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 434.0 | 434.0 | 2.0 | False | None | None | False | None | False | 868.0 | 0 | | 2854085 | 92631 | None | code14 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898... 6-32 Amps DP with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 723.0 | 723.0 | 2.0 | False | None | None | False | None | False | 1446.0 | 0 | | 2854086 | 92631 | None | code15 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure II -Doble Door 12 Way SP & N with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 1800.0 | 1800.0 | 2.0 | False | None | None | False | None | False | 3600.0 | 0 | | 2854087 | 92631 | None | code16 | Supplying of ......feet - PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80 Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1X 4' - 20/22 watts with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 375.0 | 375.0 | 4.0 | False | None | None | False | None | False | 1500.0 | 0 | | 2854088 | 92631 | None | code17 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm)..Regular model with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 2090.0 | 2090.0 | 1.0 | False | None | None | False | None | False | 2090.0 | 0 | | 2854089 | 92631 | None | code18 | Fixing a ceiling / Wall mounting fan of all capacities and alltypes to the existing 'S' hook with fan egulator to the existingboard together with upplying and fixing 5 amps. ceilingrose, necessary length of 23 / .0076 inch PVC insulatedtwin twisted copper wire and wiring with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 150.0 | 150.0 | 1.0 | False | None | None | False | None | False | 150.0 | 0 | | 2854090 | 92631 | None | code19 | Supplying and fixing of 250- 400 lamp holders with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 173.0 | 173.0 | 4.0 | False | None | None | False | None | False | 692.0 | 0 |
|
|
|---|