createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1709187081521
version14
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd945705.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose07-03-2024 16:00:00
tenderQueryClose04-03-2024 17:00:00
technicalBidOpen09-03-2024 11:00:00
publishedDate29-02-2024 13:58:14
publishedByPostNWKRTC_EE_HOFF_HUB
publishedByUserKPE12336 - DIVAKAR SHIVAPPA YARAGOPPA
bidValidityPeriod90
noOfCalls2
preBidMeetingDate04-03-2024 11:30:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnTrue
percentageRateTypeTextNone
contactPersonDivakar S Yaragoppa
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08362332383
mobileNumber7760991690
tenderSupplierListNone
tenderSchedule
createdTs1709187081524
version26
createdDateNone
modifiedDateNone
tenderNumberNWKRTC/2023-24/RD/WORK_INDENT16/CALL-2
titleConstruction of Automated Driving test track for ARTO Site at Sirsi.
descriptionConstruction of Automated Driving test track for ARTO Site at Sirsi.
categoryWORKS
categoryTextWorks
ecv63046741.50
deptNameNorth Western Karnataka Road Transport Corporation
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location6452
locationNameNorth Western Karnataka Road Transport Corporation Head Office
provisionalAmount76000000.0
groupOverheadTotalNone
fileNumberNWKRTC/EE/HBL/DB(T)/1018/2023-24
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17091870820000NoneNoneRoadsJungle clearance and Levelling and Formation4574546.89
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
285459392650Nonecode01Cutting of Trees, excluding removal of stumps and roots of trees Girth from 300 mm to 600 mm (CSR 2023-24- Vol -3 Pg 9/Sl No 2.1/ MoRT & H spec 201 / (a) (i) )Each666.4666.461.0FalseNoneNoneFalseNoneFalse40650.40
285459492650Nonecode02Cutting of Trees, excluding removal of stumps and roots of trees Girth from 600 mm to 900 mm (CSR 2023-24- Vol -3 Pg 9/Sl No 2.1/ MoRT & H spec 201 / (a) (ii) )Each1059.521059.5236.0FalseNoneNoneFalseNoneFalse38142.720
285459592650Nonecode03Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness by mechnical means using dozer in Area of light jungle (CSR 2023-24- Vol -3 Pg 9/Sl No 2.5/ MoRT & H spec 201 / (ii) (a) )Sqm4.44.416193.31FalseNoneNoneFalseNoneFalse71250.5640
285459692650Nonecode04Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work (CSR 2023-24- Vol -3 Pg 17/Sl No 3.1/ MoRT & H spec 301Cum95.295.23606.0FalseNoneNoneFalseNoneFalse343291.20
285459792650Nonecode05Engaging Tipper-10 m3 to dispose the unwanted debries collected at dust bin including loading ,unloading transportation complete (CSR 2023-24- Vol -1 Pg A47/Sl No121 )Cum1793.01793.0120.17FalseNoneNoneFalseNoneFalse215464.810
285459892650Nonecode06Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth (CSR 2023-24- Vol -1 Pg 8/Sl No 1.12)Cum106.4106.44609.0FalseNoneNoneFalseNoneFalse490397.60
285459992650Nonecode07Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment,scarified to a depth of 150 mm, mixed with water at OMC and then compacted by then compacted by rolling so as to achieve minimum dry densityrolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction. (CSR 2023-24- Vol -1 Pg 17/Sl No 3.7)Cum117.6117.61540.0FalseNoneNoneFalseNoneFalse181104.00
285460092650Nonecode08Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2 (CSR 2023-24- Vol -1 Pg 17/Sl No 3.6)Cum552.16552.165785.0FalseNoneNoneFalseNoneFalse3194245.60
17091870820000NoneNoneRoadsCompound wall9805987.28
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
285460192651Nonecode01Earth work excavation by manual means for drains,canaIs, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.In all kinds of soils Depth upto 1.5 m (CSR 2023-24 vol I /P -5 /1.4.1)Cum271.04271.04693.0FalseNoneNoneFalseNoneFalse187830.720
285460292651Nonecode02Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M7.5) Using 40 mm nominal size graded crushed coarse aggregates (CSR 2023-24 vol I /P -15 /2.1.2)Cum6343.686343.6878.0FalseNoneNoneFalseNoneFalse494807.040
285460392651Nonecode03Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (CSR 2023-24 vol I /P -15 /2.2.3)Cum7451.147451.14125.0FalseNoneNoneFalseNoneFalse931392.50
285460492651Nonecode04Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (CSR 2023-24 vol I /P -16 /2.3.2)Cum10886.410886.448.0FalseNoneNoneFalseNoneFalse522547.20
285460592651Nonecode05Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (CSR 2023-24 vol I /P -15 /2.2.3)Cum13029.0713029.0734.0FalseNoneNoneFalseNoneFalse442988.380
285460692651Nonecode06Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (CSR 2023-24 vol I /P -16 /2.3.2)Cum7983.367983.36155.0FalseNoneNoneFalseNoneFalse1237420.80
285460792651Nonecode07Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (CSR 2023-24 vol I /P -7 /1.9)Cum297.92297.92319.0FalseNoneNoneFalseNoneFalse95036.480
285460892651Nonecode08Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,roIIing,water,all materiaIs,usage& all other appurtenaces required to complete the work. (CSR 2023-24 vol I /P -7 /1.8)Cum530.88530.8897.0FalseNoneNoneFalseNoneFalse51495.360
285460992651Nonecode09Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (CSR 2023-24 vol 2 /P -77 /11.2)Kg126.56126.561565.0FalseNoneNoneFalseNoneFalse198066.40
285461092651Nonecode10Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.. (CSR 2023-24 vol 2 /P -14 /6.8)Cum8925.288925.28141.0FalseNoneNoneFalseNoneFalse1258464.480
285461192651Nonecode11Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates (CSR 2023-24 vol I /P -15 /2.1.6)Cum6992.166992.169.0FalseNoneNoneFalseNoneFalse62929.440
285461292651Nonecode12Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (CSR 2023-24 vol 2 /P -42/8.9)Sqm431.2431.22264.0FalseNoneNoneFalseNoneFalse976236.80
285461392651Nonecode13Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two coat applied @ 1.67 Itr/10 m* over and including priming coat of exterior primer applied @ 2.20 kg/10 mz) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (CSR 2023-24 vol 2 P 46/8.30)Sqm194.88194.882264.0FalseNoneNoneFalseNoneFalse441208.320
285461492651Nonecode14Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.CSR2023-24- Vol-I (P-8/item no 2.11 a )Tonne100191.84100191.8429.0FalseNoneNoneFalseNoneFalse2905563.360
17091870820000NoneNoneRoadsPavement Concrete24363179.07
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
285461592652Nonecode01Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications,including setting out, shoring, strutting, barricading, caution lights,including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work (CSR 2023-24- Vol -1 Pg 8/l No 1.14.1)Cum114.24114.24768.0FalseNoneNoneFalseNoneFalse87736.320
285461692652Nonecode02Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M7.5) Using 40 mm nominal size graded crushed coarse aggregates (CSR 2023-24 vol I /P -15 /I No 2.1.2)Cum6343.686343.68129.0FalseNoneNoneFalseNoneFalse818334.720
285461792652Nonecode03Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm ominal size graded crushed coarse For Footing aggregates (CSR 2023-24 vol I /P 17/I No 2.5.1)Cum10024.5610024.56639.0FalseNoneNoneFalseNoneFalse6405693.840
285461892652Nonecode04Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller in stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density Grading-II (53 mm to 22.4 mm) Using Screening Type B (11.2mm agg) ( CSR-2023-24 -Volume 3 P-25/ I No 4.13 A ii b /MoRT & H spec 404)Cum2423.682423.68295.0FalseNoneNoneFalseNoneFalse714985.60
285461992652Nonecode05Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. ( CSR-2023-24 -Volume 3 P-26/ I No 4.17 /MoRT & H spec 406)Cum2866.082866.08441.0FalseNoneNoneFalseNoneFalse1263941.280
285462092652Nonecode06Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing.(CSR-2023-24- Vol-III (P-49/ I No 6.9)Cum5510.45510.4295.0FalseNoneNoneFalseNoneFalse1625568.00
285462192652Nonecode07Construction of un-reinforced plain cement concrete pavement using RMC M-30 grade with OPC @ 270 kg/m3 and GGBS@ 90 kg/m3 (75:25 proportion) as per approved mix design procedure and thickness as per design, over a prepared sub base. The superplastisiser confirming to IS 9103-1999 Reaffirmed-2008 ,Coarse aggregates and Fine aggregate confirming to IS:383-2016, transported to site, laid in approved fixed side form work (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the form work). Spreading the concrete with shovels, rackers and compacted using needle, suitable plate vibrator and finished in a continuous operation including provision of separation membrane and Hessian cloth finishing to lines and grades complete including cost of all materials, labour, all lead & lift, loading charges as per specification & direction of Engineer - incharge of the work. (Groove cutting shall be paid seperately). SR 23-24, Vol-III (P 51/6.6)Cum7586.887586.88588.0FalseNoneNoneFalseNoneFalse4461085.440
285462292652Nonecode08Supplying, fitting and placing Mild Steel Reinforcement complete as per drawing and technical specification. tCSR2023-24- Vol-I (P-8/item no 2.11 a )Kg82558.5682558.5624.0FalseNoneNoneFalseNoneFalse1981405.440
285462392652Nonecode09Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.CSR2023-24- Vol-I (P-8/item no 2.11 a )Kg100191.84100191.8448.0FalseNoneNoneFalseNoneFalse4809208.320
285462492652Nonecode10Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (CSR 2023-24 vol 2 /P -77 /11.2)Kg126.56126.566050.0FalseNoneNoneFalseNoneFalse765688.00
285462592652Nonecode11Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge (CSR 2023-24 VOL 2 Page no 46/ It no 8.33.2)Sqm154.56154.56801.0FalseNoneNoneFalseNoneFalse123802.560
285462692652Nonecode12Cutting transverse contraction joints 3 to 4 mm wide and depth 60mm in concrete slab using concrete cutting machine with diamond studded saw within 4-8 hours of casting of bay / slab etc. complete including subsequent widening of the groove 8 to 10 mm. wide at top having depth of 15 mm. as directed by Engineer incharge. (SR 23-24 p No 163/17-c/4/ MoRTH 602.6.3)Rmtr78.478.41263.0FalseNoneNoneFalseNoneFalse99019.20
285462792652Nonecode13Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 300 x 300 x 150 mm Kerb Stone .(CSR-2023-24-Vol 3 P no 74,/ I no 8.42.7)Rmtr421.12421.121143.0FalseNoneNoneFalseNoneFalse481340.160
285462892652Nonecode14Providing and laying in position plain cement concrete for levellingcourse for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregate. (CSR 2023-24 vol I /P -15 /2.1.2)Rmtr6343.686343.6826.16FalseNoneNoneFalseNoneFalse165950.66880
285462992652Nonecode15Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.(Vol 2 Page no 26 / It no 7.38)Sqm636.16636.1635.0FalseNoneNoneFalseNoneFalse22265.60
285463092652Nonecode16Laying Cement Concrete Pipe NP3 (burried conduits) on first class bedding of granular material including fixing collar with cement sand mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonary work in head wall and parapets 500 mm dia (Vol 3 P-135 / 20.18/)Rmtr2903.042903.0460.0FalseNoneNoneFalseNoneFalse174182.40
285463192652Nonecode17Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. PVC pipes 200mm dia., 10 kg/sqcm & class 3 (vol 5 Item No 15.6 ,SOR Code M150AB)Rmtr1878.241878.24100.0FalseNoneNoneFalseNoneFalse187824.00
285463292652Nonecode18Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 .(CSR2023-24-Vol 2 Page no144 / It no 14.90)No6319.046319.0413.0FalseNoneNoneFalseNoneFalse82147.520
285463392652Nonecode19Hydraulic Excavator of 1.1 m3 bucket (Vol 1 p n A-44 /Sl no 50)hr1550.01550.060.0FalseNoneNoneFalseNoneFalse93000.00
17091870820000NoneNoneRoadsSanitary block & Septic tank2676634.41
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
285463492653Nonecode01Earth work excavation by manual means for drains,canaIs, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.In all kinds of soils Depth upto 1.5 m (CSR 2023-24 vol I /P -5 /1.4.1)Cum271.04271.04118.0FalseNoneNoneFalseNoneFalse31982.720
285463592653Nonecode02Earth work excavation by manual means for drains,canaIs, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.Depth exceeding 1.5m, but not exceeding 3 mSRP vol I (P-5/1.4.2)Cum290.08290.0852.0FalseNoneNoneFalseNoneFalse15084.160
285463692653Nonecode03Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M7.5) Using 40 mm nominal size graded crushed coarse aggregates (CSR 2023-24 vol I /P -15 /2.1.2)Cum6343.686343.6818.0FalseNoneNoneFalseNoneFalse114186.240
285463792653Nonecode04Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (CSR 2023-24 vol I /P -15 /2.2.3)Cum7309.217309.2119.0FalseNoneNoneFalseNoneFalse138874.990
285463892653Nonecode05Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (CSR 2023-24 vol I /P -16/2.5.2)Cum13029.0713029.076.0FalseNoneNoneFalseNoneFalse78174.420
285463992653Nonecode06Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (CSR 2023-24 vol I /P -16 /2.3.2)Cum10886.410886.46.0FalseNoneNoneFalseNoneFalse65318.40
285464092653Nonecode07Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (CSR 2023-24 vol I /P -16/2.5.2)Cum12262.6612262.666.0FalseNoneNoneFalseNoneFalse73575.960
285464192653Nonecode08Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (CSR 2023-24 vol I /P -16/2.5.2)Cum11496.2411496.249.0FalseNoneNoneFalseNoneFalse103466.160
285464292653Nonecode09Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (CSR 2023-24 vol I /P -16/2.5.2)Cum11113.0311113.032.0FalseNoneNoneFalseNoneFalse22226.060
285464392653Nonecode10Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (CSR 2023-24 vol I /P -7 /1.9)Cum297.92297.92129.0FalseNoneNoneFalseNoneFalse38431.680
285464492653Nonecode11Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,roIIing,water,all materiaIs,usage& all other appurtenaces required to complete the work. (CSR 2023-24 vol I /P -7 /1.8)Cum530.88530.8832.0FalseNoneNoneFalseNoneFalse16988.160
285464592653Nonecode12Providing and fixing M.S. grills of required pattern in frames of win- dows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.CSR- Vol-II (P-86/11.34 B)Kg204.96204.96472.0FalseNoneNoneFalseNoneFalse96741.120
285464692653Nonecode13Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.. (CSR 2023-24 vol 2 /P -14 /6.8)Cum8925.288925.2832.0FalseNoneNoneFalseNoneFalse285608.960
285464792653Nonecode14Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge CSR-2023-24 Vol-II (41/8.2.1)Sqm330.4330.4245.0FalseNoneNoneFalseNoneFalse80948.00
285464892653Nonecode15Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. CSR-2023-24 Vol-II (41/8.1 .2)Sqm269.92269.9285.0FalseNoneNoneFalseNoneFalse22943.20
285464992653Nonecode16Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (CSR 2023-24 vol 2 /P -42/8.9)Sqm431.2431.2185.0FalseNoneNoneFalseNoneFalse79772.00
285465092653Nonecode17Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.CSR-2023-24 - Vol-II (P-50/8.51)Sqm112.0112.0235.0FalseNoneNoneFalseNoneFalse26320.00
285465192653Nonecode18Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. CSR2023-24- Vol-II (P-104/12.54)Rmtr356.16356.1645.0FalseNoneNoneFalseNoneFalse16027.20
285465292653Nonecode19Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.CSR-2023-24- Vol-II (P-104/12.55.2) with one side prelam.Sqm2284.82284.812.0FalseNoneNoneFalseNoneFalse27417.60
285465392653Nonecode20Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye,River Pink or equivalent. SRP- Vol-II (P-63/9.24)Sqm3194.243194.2411.0FalseNoneNoneFalseNoneFalse35136.640
285465492653Nonecode21Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc.complete as per design approved by Engineer-in-charge. SRP- Vol-II (P-69/10.2)Rmtr301.28301.2825.0FalseNoneNoneFalseNoneFalse7532.00
285465592653Nonecode22Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.CSR2023-24- Vol-I (P-8/item no 2.11 a )Kg100191.84100191.844.5FalseNoneNoneFalseNoneFalse450863.280
285465692653Nonecode23Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 .(CSR2023-24-Vol 2 Page no144 / It no 14.90)No6319.046319.048.0FalseNoneNoneFalseNoneFalse50552.320
285465792653Nonecode24Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 110mm dia., 6 kg/sqcm & class 3 (vol 4, chapter 12, No 1.7, SOR CODE M010G)Rmtr441.28441.2835.0FalseNoneNoneFalseNoneFalse15444.80
285465892653Nonecode25KSupplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 160mm dia., 6 kg/sqcm & class 3 (vol 4, chapter 12, No 1.9, SOR CODE M010 I)Rmtr670.88670.8878.0FalseNoneNoneFalseNoneFalse52328.640
285465992653Nonecode26Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :”* Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent.(CSR 2023-24-vol 2, chapter 9, P-63 /9.23)Sqm2761.922761.9216.0FalseNoneNoneFalseNoneFalse44190.720
285466092653Nonecode27Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. (CSR-2023-24-Vol 2 Page no 60/It no 9.9)Sqm995.68995.6844.0FalseNoneNoneFalseNoneFalse43809.920
285466192653Nonecode28Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. CSR-2023-24- Vol-II (65/9.38)Sqm1559.041559.0498.0FalseNoneNoneFalseNoneFalse152785.920
285466292653Nonecode29Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. CSR2023-24- Vol-II (45/8.25)Sqm153.44153.44236.0FalseNoneNoneFalseNoneFalse36211.840
285466392653Nonecode30Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two coat applied @ 1.67 Itr/10 m* over and including priming coat of exterior primer applied @ 2.20 kg/10 mz) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.CSR2023-24-Vol-II (46/8.30)Sqm194.88194.88186.0FalseNoneNoneFalseNoneFalse36247.680
285466492653Nonecode31Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge..(vol 2 p-48 / 8.41 )Sqm187.04187.0425.0FalseNoneNoneFalseNoneFalse4676.00
285466592653Nonecode32Providing and placing on terrace (at all floor levels) polyethylene water storage tanks IS:12701 marked with cover and suitable locking arrangements and making necesary holes for inlet outlet and over flow pipes but without fittings and the base support for tank. CSR2023-24- Vol. II/P123 I No 13.34Ltr10.0810.084000.0FalseNoneNoneFalseNoneFalse40320.00
285466692653Nonecode33Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brasspillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Surgeon type wash basin of size 660x460 mm with single 15 mm C.P. brass pillar taps with elbow operated levers ISI Marked SRP- Vol-II (133/14.7.9)Nos3857.283857.282.0FalseNoneNoneFalseNoneFalse7714.560
285466792653Nonecode34Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete,including painting of fittings and brackets, cutting and making good the walls and floors wherever required. W.C. pan with ISI marked white solid plastic seat and lid.SRP- Vol-II (131/14.3.1)Each6694.246694.242.0FalseNoneNoneFalseNoneFalse13388.480
285466892653Nonecode35Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level whiteP.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm withintegral type foot rests Vol II (SRP 131/14.1.1)Nos5470.085470.085.0FalseNoneNoneFalseNoneFalse27350.40
285466992653Nonecode36Providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe, white P.V.C. automatic flushing cistern, with fittings, standard size G.I. / PVC flush pipe for back and front flush with standard spreader pipes with fittings,G.I clamps and C.P. brass coupling complete, including painting of fittings and cutting and making good the walls and floors etc. wherever required :Single squatting plate with 5 litre P.V.C. automatic flushing cisternVol II (SRP 131/14.6.1)Nos7414.47414.43.0FalseNoneNoneFalseNoneFalse22243.20
285467092653Nonecode37Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS: 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :Vol II (SRP 132/14.5.1)Each9679.049679.046.0FalseNoneNoneFalseNoneFalse58074.240
285467192653Nonecode38Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Oval Shape 450 X350 mm (Outer dimension) SRP- Vol-II (136/14.32.3)Unit1193.921193.922.0FalseNoneNoneFalseNoneFalse2387.840
285467292653Nonecode39Providing and fixing 100 mm sand cast Iron grating for gully trap.(SRP vol -2,P-136 / 14.29)Each52.6452.648.0FalseNoneNoneFalseNoneFalse421.120
285467392653Nonecode40Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand) (SRP - Vol I/P-9 /Sl No 5.1.1)Cum6284.326284.326.0FalseNoneNoneFalseNoneFalse37705.920
285467492653Nonecode41Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) With common burnt clay (non modular) bricks of class designation 3.5. (CSR 2023-24 Vol.2/126/13.52)Nos11833.9211833.923.0FalseNoneNoneFalseNoneFalse35501.760
285467592653Nonecode42Engaging tractor to dispose the unwanted debries collected at dust bin including loading ,unloading transportation complete (vol I p-A47/ 127)Hour659.0659.016.0FalseNoneNoneFalseNoneFalse10544.00
285467692653Nonecode43Engaging Hydraulic Excavaterof 1.1 m3 bucket to dispose the unwanted debries collected at dust bin including loading ,unloading transportation complete (vol I p-A44/ 50)Hour1550.01550.016.0FalseNoneNoneFalseNoneFalse24800.00
285467792653Nonecode44Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete.(csr2023-24 -vol II p-105/ 12.61)No1108.81108.814.0FalseNoneNoneFalseNoneFalse15523.20
285467892653Nonecode45Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete.(csr2023-24 -vol II p-105/ 12.62)No265.4265.414.0FalseNoneNoneFalseNoneFalse3715.60
285467992653Nonecode46Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete(csr2023-24 -vol II p-105/ 12.63)No695.5695.57.0FalseNoneNoneFalseNoneFalse4868.50
285468092653Nonecode47Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(CSR 2023-24 -Vol 2 P-85 / 11.28)Kg632.8632.8171.0FalseNoneNoneFalseNoneFalse108208.80
17091870820000NoneNoneRoadsPaver3460327.92
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
285468192654Nonecode01Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications,including setting out, shoring, strutting, barricading, caution lights,including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work (CSR 2023-24- Vol -1 Pg 8/l No 1.14.1)Cum114.24114.24264.0FalseNoneNoneFalseNoneFalse30159.360
285468292654Nonecode02Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M7.5) Using 40 mm nominal size graded crushed coarse aggregates (CSR 2023-24 vol I /P -15 /2.1.2)Cum6343.686343.686.0FalseNoneNoneFalseNoneFalse38062.080
285468392654Nonecode03Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm ominal size graded crushed coarse For Footing aggregates (CSR 2023-24 vol I /P 16/I No 2.5.1)Cum10024.5610024.5615.0FalseNoneNoneFalseNoneFalse150368.40
285468492654Nonecode04Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. ( CSR-2023-24 -Volume 3 P-26/ I No 4.17 /MoRT & H spec 406)Cum2866.082866.08201.0FalseNoneNoneFalseNoneFalse576082.080
285468592654Nonecode05Providing and laying 80mm thick factory made precast M -30 grade Cement Concrete Paver Block as per IRC SP 63:2018 & IS 15658 for Commercial Traffic Axle load repetitions upto 10MSA & for Residential Streets of approved shape and colour, laid in required pattern and including over 40mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (WMM/WBM Base to be paid separately as per relevant technical specification) CSR 2023-24/Vol.3/51/6.8.2Cum1300.321300.322050.0FalseNoneNoneFalseNoneFalse2665656.00
17091870820000NoneNoneRoadsSinking of Water883519.84
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
285468692655Nonecode01Geophysical investigation at site for sinking borewells for supplying drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers’s method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test (SRP Vol-5 / 151 /4)No5757.925757.921.0FalseNoneNoneFalseNoneFalse5757.920
285468792655Nonecode02Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for Borewell depth of 0 to 50 m (SRP Vol 5 / 151 / 2.1)Rmtr337.12337.1250.0FalseNoneNoneFalseNoneFalse16856.00
285468892655Nonecode03Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for Borewell depth of 50 to 100 m (SRP Vol-5 / 151 /2.2)Rmtr422.24422.2450.0FalseNoneNoneFalseNoneFalse21112.00
285468992655Nonecode04Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for Borewell depth of 100 to 150 m (SRP Vol- 5 / 151 / 2.3)Rmtr449.12449.1250.0FalseNoneNoneFalseNoneFalse22456.00
285469092655Nonecode05Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for PVC pipes 160mm dia., 6 kg/sqcm & class 3 (SRP Vol- 5 / 134 / 1.9)Rmtr670.88670.8850.0FalseNoneNoneFalseNoneFalse33544.00
285469192655Nonecode06Providing and fixing gun metal non- return valve of approved quality (screwed end) Vertical : (CSR2023-24 Vol-2 /Pg 118 /I No 13.6.4.2)Nos1711.361711.361.0FalseNoneNoneFalseNoneFalse1711.360
285469292655Nonecode07Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete. (internal work exposed on wall) - 50mm nominal OD pipes (CSR2023-24 Vol-2 /Pg 122 /I No 13.31.6)Sqm874.72874.72150.0FalseNoneNoneFalseNoneFalse131208.00
285469392655Nonecode08Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark , For 20 mm dia GM (Copper alloy) Gate valves (SRP Vol-5 / 147 / 16.2 )No994.56994.564.0FalseNoneNoneFalseNoneFalse3978.240
285469492655Nonecode09Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark , For 50 mm dia GM (Copper alloy) Gate valves (SRP Vol-5 / 147 / 16.2 )No1890.561890.565.0FalseNoneNoneFalseNoneFalse9452.80
285469592655Nonecode10Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark ,For 40 mm dia GM (Copper alloy) Gate valves (SRP Vol-5 / 147 / 16.5 )No1680.01680.05.0FalseNoneNoneFalseNoneFalse8400.00
285469692655Nonecode11Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark ,For 25 mm dia GM (Copper alloy) Gate valves (SRP Vol-5 / 147 / 16.3 )No1309.281309.284.0FalseNoneNoneFalseNoneFalse5237.120
285469792655Nonecode12Providing stoneware gully trap of approved quality and make fixing in M-15 and plastering with CM 1:3 wherever necessary.( Rate includes cost of all materials, fixtures and lead). - 15cms x 10cms (SRP 12.112.2) ( Old SER 2018-19)No313.6313.64.0FalseNoneNoneFalseNoneFalse1254.40
285469892655Nonecode13Providing and fixing chorinated poly venyl chloride(CPVC) pipes having thermal stability for hot & cold water supply including all CPVC plain and brass threaded fittings this includes jointing of pipes and fittings of joints complete as per Engineer in charge. Internal work, exposed on wall. 40 mm nominal OD pipes (CSR 2023-24-Vol.2 Pg122/Ino 13.31.5)Rmtr600.32600.32200.0FalseNoneNoneFalseNoneFalse120064.00
285469992655Nonecode14Providing and fixing chorinated poly venyl chloride(CPVC) pipes having thermal stability for hot & cold water supply including all CPVC plain and brass threaded fittings this includes jointing of pipes and fittings of joints complete as per Engineer in charge. Internal work, exposed on wall. 32 mm nominal OD pipes. (CSR 2023-24-Vol.2 Pg122/Ino 13.31.4)Rmtr448.0448.0200.0FalseNoneNoneFalseNoneFalse89600.00
285470092655Nonecode15Water purification plants: Supplying, Installation and Commissioning of automatic Water purification plant RO+UF) with all accessories piping, product water tank on single phase power supply as per the enclosed detailed Technical Specifications including cost of material, loading and unloading and as directed by the Engineer in charge. (Ref- detailed specification enclosed seperatly). Note:- 1.The above rates mentioned are only for the preparation of estimate purpose. 2. All items are to be of BSI /NFS standards,with BSI / NFS mark . 3. Tenders to be invited for procurement. 4. No direct payment should be made under any situation or condition or on any account. 5. After commissioning of plant necessary testing to be done for the satisfactory of Engineer Incharge. Note : Refer the ANNEXURE : F for Detailed Specification of Each components. For 500 LPH SS : Skid Type (SRP Vol-5 / 227 / 1.7/Y010G )Nos412888.0412888.01.0FalseNoneNoneFalseNoneFalse412888.00
17091870820000NoneNoneRoadsSump tank330158.27
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
285470192656Nonecode01Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications,including setting out, shoring, strutting, barricading, caution lights,including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work (CSR 2023-24- Vol -1 Pg 8/l No 1.14.1)Cum114.24114.2455.88FalseNoneNoneFalseNoneFalse6383.73120
285470292656Nonecode02Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M7.5) Using 40 mm nominal size graded crushed coarse aggregates (CSR 2023-24 vol I /P -15 /2.1.2)Cum6343.686343.683.35FalseNoneNoneFalseNoneFalse21251.3280
285470392656Nonecode03Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm ominal size graded crushed coarse For Footing aggregates (CSR 2023-24 vol I /P 16/I No 2.5.1)Cum11880.9611880.9613.17FalseNoneNoneFalseNoneFalse156472.24320
285470492656Nonecode04Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as perspecificat ions and as per directions of Engineer-in-charge. CSR-2023-24 Vol-II (41/8.2.2)Sqm312.48312.4866.6FalseNoneNoneFalseNoneFalse20811.1680
285470592656Nonecode05Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.CSR2023-24- Vol-I (P-8/item no 2.11 a )Kg100191.84100191.841.25FalseNoneNoneFalseNoneFalse125239.80
17091870820000NoneNoneRoadsControl room for LMV and Two Wheeler2915016.23
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
285470692657Nonecode01Earth work excavation by manual means for drains,canaIs, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.In all kinds of soils Depth upto 1.5 m (CSR 2023-24 vol I /P -5 /1.4.1)Cum271.04271.04102.0FalseNoneNoneFalseNoneFalse27646.080
285470792657Nonecode02Earth work excavation by manual means for drains,canaIs, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.Depth exceeding 1.5m, but not exceeding 3 mSRP vol I (P-5/1.4.2)Cum290.08290.0856.0FalseNoneNoneFalseNoneFalse16244.480
285470892657Nonecode03Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M7.5) Using 40 mm nominal size graded crushed coarse aggregates (CSR 2023-24 vol I /P -15 /2.1.2)Cum6343.686343.6828.0FalseNoneNoneFalseNoneFalse177623.040
285470992657Nonecode04Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (CSR 2023-24 vol I /P -15 /2.2.3)Cum7451.147451.1430.0FalseNoneNoneFalseNoneFalse223534.20
285471092657Nonecode05Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (CSR 2023-24 vol I /P -16/2.5.2)Cum13029.0713029.078.0FalseNoneNoneFalseNoneFalse104232.560
285471192657Nonecode06Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (CSR 2023-24 vol I /P -16 /2.3.2)Cum10886.410886.46.0FalseNoneNoneFalseNoneFalse65318.40
285471292657Nonecode07Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (CSR 2023-24 vol I /P -16/2.5.2)Cum12262.6612262.666.0FalseNoneNoneFalseNoneFalse73575.960
285471392657Nonecode08Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (CSR 2023-24 vol I /P -16/2.5.2)Cum11496.2411496.2415.0FalseNoneNoneFalseNoneFalse172443.60
285471492657Nonecode09Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (CSR 2023-24 vol I /P -16/2.5.2)Cum11113.0311113.033.0FalseNoneNoneFalseNoneFalse33339.090
285471592657Nonecode10Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (CSR 2023-24 vol I /P -7 /1.9)Cum297.92297.92120.0FalseNoneNoneFalseNoneFalse35750.40
285471692657Nonecode11Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,roIIing,water,all materiaIs,usage& all other appurtenaces required to complete the work. (CSR 2023-24 vol I /P -7 /1.8)Cum530.88530.8843.0FalseNoneNoneFalseNoneFalse22827.840
285471792657Nonecode12Providing and fixing M.S. grills of required pattern in frames of win- dows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.CSR- Vol-II (P-86/11.34 B)Kg204.96204.96802.0FalseNoneNoneFalseNoneFalse164377.920
285471892657Nonecode13Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement: 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. (CSR 2023-24 vol 2 /P -13 /6.3)Cum7816.487816.4833.0FalseNoneNoneFalseNoneFalse257943.840
285471992657Nonecode14Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge CSR-2023-24 Vol-II (41/8.2.1)Sqm330.4330.4160.0FalseNoneNoneFalseNoneFalse52864.00
285472092657Nonecode15Providing 12 mm cement plaster with cement mortar 1:6 (1 cement:6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. CSR-2023-24 Vol-II (41/8.2.1)Sqm269.92269.92100.0FalseNoneNoneFalseNoneFalse26992.00
285472192657Nonecode16Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (CSR 2023-24 vol 2 /P -42/8.9)Sqm431.2431.2277.0FalseNoneNoneFalseNoneFalse119442.40
285472292657Nonecode17Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.CSR-2023-24 - Vol-II (P-50/8.51)Sqm112.0112.0264.0FalseNoneNoneFalseNoneFalse29568.00
285472392657Nonecode18Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.CSR2023-24- Vol-II (99/12.12)Cum139106.24139106.240.15FalseNoneNoneFalseNoneFalse20865.9360
285472492657Nonecode19Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot ressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991.from manufacturer complete as per spcification.SRP- Vol-II (105/12.57.5)-do- 35 mm thick one side teak and one side commercialSqm4364.644364.646.0FalseNoneNoneFalseNoneFalse26187.840
285472592657Nonecode20Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-incharge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications.(CSR2023-24 Vol II Pg87/ I No 11.35.1.2)Kg547.68547.68244.0FalseNoneNoneFalseNoneFalse133633.920
285472692657Nonecode21Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/m) including cost of materials, labour, usage charges of machinery complete as per specifications.(csr2023-24-vol II P-89/11.37.1)Sqm1107.681107.6832.0FalseNoneNoneFalseNoneFalse35445.760
285472792657Nonecode22Providing and laying Polished Glazed Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement basedhigh polymer modified quick set tile adhesive (water based) conforming (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm CSR2023-24- Vol-II (62/9.22.2)Sqm1485.121485.1266.0FalseNoneNoneFalseNoneFalse98017.920
285472892657Nonecode23Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab,including cost of materials,labour,curing, polishing complete as per specifications.CSR2023-24- Vol-II (64/9.34)Sqm1730.41730.48.0FalseNoneNoneFalseNoneFalse13843.20
285472992657Nonecode24Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.CSR2023-24- Vol-I (P-8/item no 2.11 a )Tonne100191.84100191.846.5FalseNoneNoneFalseNoneFalse651246.960
285473092657Nonecode25Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 .(CSR2023-24-Vol 2 Page no144 / It no 14.90)No6319.046319.046.0FalseNoneNoneFalseNoneFalse37914.240
285473192657Nonecode26Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 110mm dia., 6 kg/sqcm & class 3 (vol 4, chapter 12, No 1.7, SOR CODE M010G)Rmtr441.28441.2843.0FalseNoneNoneFalseNoneFalse18975.040
285473292657Nonecode27Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :”* Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent.(CSR2023-24 /vol 2, P-63 /9.23)Sqm2761.922761.9221.0FalseNoneNoneFalseNoneFalse58000.320
285473392657Nonecode28Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. CSR2023-24- Vol-II (45/8.25)Sqm153.44153.44267.0FalseNoneNoneFalseNoneFalse40968.480
285473492657Nonecode29Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two coat applied @ 1.67 Itr/10 m* over and including priming coat of exterior primer applied @ 2.20 kg/10 mz) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.CSR2023-24-Vol-II (46/8.30)Sqm194.88194.88279.0FalseNoneNoneFalseNoneFalse54371.520
285473592657Nonecode30Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(CSR-2023-24-vol 2 p-48 / 8.41 )Sqm187.04187.0443.0FalseNoneNoneFalseNoneFalse8042.720
285473692657Nonecode31Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, griding the edge to half/full round wherever required, labour, curing complete as per pecification. CSR2023-24- Vol-II (65/9.40)Sqm1043.841043.84109.0FalseNoneNoneFalseNoneFalse113778.560
17091870820001NoneNoneRoadsAdministrative Block6565258.85
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
285473792658Nonecode01Earth work excavation by manual means for drains,canaIs, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.In all kinds of soils Depth upto 1.5 m (CSR 2023-24 vol I /P -5 /1.4.1)Cum271.04271.04190.0FalseNoneNoneFalseNoneFalse51497.60
285473892658Nonecode02Earth work excavation by manual means for drains,canaIs, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.Depth exceeding 1.5m, but not exceeding 3 mSRP vol I (P-5/1.4.2)Cum290.08290.08102.0FalseNoneNoneFalseNoneFalse29588.160
285473992658Nonecode03Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M7.5) Using 40 mm nominal size graded crushed coarse aggregates (CSR 2023-24 vol I /P -15 /2.1.2)Cum6343.686343.6844.0FalseNoneNoneFalseNoneFalse279121.920
285474092658Nonecode04Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (CSR 2023-24 vol I /P -15 /2.2.3)Cum7309.217309.2150.0FalseNoneNoneFalseNoneFalse365460.50
285474192658Nonecode05Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (CSR 2023-24 vol I /P -16 /2.3.2)Cum12337.9212337.926.0FalseNoneNoneFalseNoneFalse74027.520
285474292658Nonecode06Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (CSR 2023-24 vol I /P -16 /2.3.2)Cum7983.367983.3631.0FalseNoneNoneFalseNoneFalse247484.160
285474392658Nonecode07Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (CSR 2023-24 vol I /P -16 /2.3.2)Cum10886.410886.416.0FalseNoneNoneFalseNoneFalse174182.40
285474492658Nonecode08Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (CSR 2023-24 vol I /P -7 /1.9)Cum297.92297.92162.0FalseNoneNoneFalseNoneFalse48263.040
285474592658Nonecode09Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,roIIing,water,all materiaIs,usage& all other appurtenaces required to complete the work. (CSR 2023-24 vol I /P -7 /1.8)Cum530.88530.88177.0FalseNoneNoneFalseNoneFalse93965.760
285474692658Nonecode10Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (CSR 2023-24 vol I /P -16/2.5.2)Cum13029.0713029.077.0FalseNoneNoneFalseNoneFalse91203.490
285474792658Nonecode11Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (CSR 2023-24 vol I /P -16/2.5.2)Cum11354.1111354.1119.0FalseNoneNoneFalseNoneFalse215728.090
285474892658Nonecode12Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (CSR 2023-24 vol I /P -16/2.5.2)Cum11496.2411496.2436.0FalseNoneNoneFalseNoneFalse413864.640
285474992658Nonecode13Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (CSR 2023-24 vol I /P -16/2.5.2)Cum11113.0311113.032.0FalseNoneNoneFalseNoneFalse22226.060
285475092658Nonecode14Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (CSR 2023-24 vol I /P -15 /2.2.3)Cum7096.327096.321.0FalseNoneNoneFalseNoneFalse7096.320
285475192658Nonecode15Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.CSR2023-24- Vol-I (P-8/item no 2.11 a )Tonne100191.84100191.8419.75FalseNoneNoneFalseNoneFalse1978788.840
285475292658Nonecode16Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.. (CSR 2023-24 vol 2 /P -14 /6.8)Cum7816.487816.4844.0FalseNoneNoneFalseNoneFalse343925.120
285475392658Nonecode17Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.CSR2023-24- Vol-II (99/12.12)Cum139106.24139106.240.8FalseNoneNoneFalseNoneFalse111284.9920
285475492658Nonecode18Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot ressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991.from manufacturer complete as per spcification.SRP- Vol-II (105/12.57.5)-do- 35 mm thick one side teak and one side commercialSqm4364.644364.6427.0FalseNoneNoneFalseNoneFalse117845.280
285475592658Nonecode19Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. CSR2023-24- Vol-II (P-104/12.54)Rmtr356.16356.1622.4FalseNoneNoneFalseNoneFalse7977.9840
285475692658Nonecode20Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.CSR-2023-24- Vol-II (P-104/12.55.2) with one side prelam.Sqm2284.82284.86.3FalseNoneNoneFalseNoneFalse14394.240
285475792658Nonecode21Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-incharge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications.(CSR2023-24 Vol II Pg87/ I No 11.35.1.2)Sqm547.68547.68109.1FalseNoneNoneFalseNoneFalse59751.8880
285475892658Nonecode22Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/m degree) including cost of materials, labour, usage charges of machinery complete as per specifications.(csr2023-24-vol II P-89/11.37.1)Sqm1107.681107.6819.8FalseNoneNoneFalseNoneFalse21932.0640
285475992658Nonecode23Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete: Upto 5mm depth and 5 mm width including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineerin-Charge. (CSR 2021-22-VOLUME -2/PAGE No 91/SL No 11.42.1)Rmtr69.4469.4460.0FalseNoneNoneFalseNoneFalse4166.40
285476092658Nonecode24Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(CSR 2023-24 -Vol 2 P-85 / 11.28)Nos632.8632.816.0FalseNoneNoneFalseNoneFalse10124.80
285476192658Nonecode25Providing and laying Polished Glazed Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement basedhigh polymer modified quick set tile adhesive (water based) conforming (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm CSR2023-24- Vol-II (62/9.22.2)Sqm1485.121485.12197.0FalseNoneNoneFalseNoneFalse292568.640
285476292658Nonecode26Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. (CSR-2023-24-Vol 2 Page no 60/It no 9.9)Sqm995.68995.6818.0FalseNoneNoneFalseNoneFalse17922.240
285476392658Nonecode27Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. CSR-2023-24- Vol-II (65/9.38)Sqm1559.041559.0479.0FalseNoneNoneFalseNoneFalse123164.160
285476492658Nonecode28Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja,facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications. CSR-2023-24- Vol-II -44/8.16a)Sqm1386.561386.5619.0FalseNoneNoneFalseNoneFalse26344.640
285476592658Nonecode29Providing and fixing M.S. grills of required pattern in frames of win- dows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.CSR- Vol-II (P-86/11.34 B)Kg204.96204.96548.1FalseNoneNoneFalseNoneFalse112338.5760
285476692658Nonecode30Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. CSR-2023-24 Vol-II (41/8.2.1)Sqm330.4330.4466.0FalseNoneNoneFalseNoneFalse153966.40
285476792658Nonecode31Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. CSR-2023-24 Vol-II Page no 42/8.9)Sqm431.2431.2216.0FalseNoneNoneFalseNoneFalse93139.20
285476892658Nonecode32Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. CSR-2023-24 Vol-II (41/8.1 .2)Sqm269.92269.92197.0FalseNoneNoneFalseNoneFalse53174.240
285476992658Nonecode33Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.CSR-2023-24 - Vol-II (P-50/8.51)Sqm112.0112.0663.0FalseNoneNoneFalseNoneFalse74256.00
285477092658Nonecode34Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. CSR2023-24- Vol-II (45/8.25)Sqm153.44153.44663.0FalseNoneNoneFalseNoneFalse101730.720
285477192658Nonecode35Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge (CSR2023-24 Page no 46/ It no 8.33.2)Sqm154.56154.56216.0FalseNoneNoneFalseNoneFalse33384.960
285477292658Nonecode36Providing and fixing on wall face unplastisied rigid PVC Rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS : 5382, Leaving 10mm gapthermal expansion, (i) Single socketed pipes 100mm diameter. (Vol 2/ Page no It no 13.48) (Ist Addenda)Rmtr283.36283.3660.0FalseNoneNoneFalseNoneFalse17001.60
285477392658Nonecode37Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5.(Vol 2 Page no 44/It no 14.90)No6319.046319.044.0FalseNoneNoneFalseNoneFalse25276.160
285477492658Nonecode38KSRB 12-1.2 : Providing and laying in position to required level or slope 150mm internal diameter salt glazed stoneware pipes grade A and jointing with stiff mixture of cement mortar in proportion of 1:1, testing of pipes and joints,including cost of materials, labour charges complete as per specifications. Specification No. KBS 12.2.5 / 12.7 (SR2018-19/P 72/11.2)Rmtr413.28413.2830.0FalseNoneNoneFalseNoneFalse12398.40
285477592658Nonecode39Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) With common burnt clay (non modular) bricks of class designation 3.5(SR Vol.3 / 26/13.52)No11833.9211833.921.0FalseNoneNoneFalseNoneFalse11833.920
285477692658Nonecode40Supplying S&S RCC SPUN / VIBRATED CAST PIPES (REINFORCED) pipes NP-3 Class conforming to IS:458-1988 with latest amentments using ordinary portland cement, for sanitary works and conveying to work site, rolling and lowering into trenches, laying true to line and level including loading and unloading at both destinations and jointing of pipes and specials, perfect linking of joints with jack to correct position including cost of jointing materials, i.e, rubber rings conforming to IS: 5382 for S&S RCC pipes, with all leads and lifts as directed and giving necessary hydraulic test as per ISS to the required pressure and commissioning etc. complete. (Contractor will make his own arrangements for procuring water for testing). Before the execution of the work, the contractor shall carry out the survey. RCC NP3 Class pipe of 300 mm dia (Vol 5 Page no 185/It no 3.2/T050B)Rmtr1248.81248.830.0FalseNoneNoneFalseNoneFalse37464.00
285477792658Nonecode41Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brasspillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Surgeon type wash basin of size 660x460 mm with single 15 mm C.P. brass pillar taps with elbow operated levers ISI Marked SRP- Vol-II (133/14.7.9)No3857.283857.284.0FalseNoneNoneFalseNoneFalse15429.120
285477892658Nonecode42Providing and fixing 100 mm sand cast Iron grating for gully trap.(SRP vol -2,P-136 / 14.29)No52.6452.645.0FalseNoneNoneFalseNoneFalse263.20
285477992658Nonecode43Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Oval Shape 450 X350 mm (Outer dimension) SRP- Vol-II (136/14.32.3)No1193.921193.925.0FalseNoneNoneFalseNoneFalse5969.60
285478092658Nonecode44Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 g.(Vol 2 Page no 130/ It no 14.40.1)No398.72398.725.0FalseNoneNoneFalseNoneFalse1993.60
285478192658Nonecode45Providing and fixing CI Nahani trap of 12.5cmsx7.5cms approved make conforming to ISI specifications and constructions of Cistern in CC 1;2;4 as per directions ( Rate is inclusive of materials and fixtures and converyance of materials to work spot) (SR2018-19/P 90/12.113.2)No319.2319.25.0FalseNoneNoneFalseNoneFalse1596.00
285478292658Nonecode46Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.(Vol 2 Page no 54 / It no 8.79)Rmtr44.844.8200.0FalseNoneNoneFalseNoneFalse8960.00
285478392658Nonecode47Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete,including painting of fittings and brackets, cutting and making good the walls and floors wherever required. W.C. pan with ISI marked white solid plastic seat and lid.SRP- Vol-II (131/14.3.1)No6694.246694.244.0FalseNoneNoneFalseNoneFalse26776.960
285478492658Nonecode48Providing & fixing in position brass stop cock of approved quality 15mm nominal bore. (CSR 2023-24 Vol 2/Page no. 117/It no 13.3.1)No334.88334.8810.0FalseNoneNoneFalseNoneFalse3348.80
285478592658Nonecode49Providing and fixing chorinated poly venyl chloride(CPVC) pipes having thermal stability for hot & cold water supply including all CPVC plain and brass threaded fittings this includes jointing of pipes and fittings of joints complete as per Engineer in charge. Internal work, exposed on wall. 32 mm nominal OD pipes. (CSR 2023-24-Vol.2 Pg122/Ino 13.31.4)Rmtr448.0448.031.5FalseNoneNoneFalseNoneFalse14112.00
285478692658Nonecode50Providing and fixing brass bib cock of approved quality : 15 mm nominal bore (CSR 2023-24 Vol 2/Page no. 117/It no 13.2.1)No320.32320.3210.0FalseNoneNoneFalseNoneFalse3203.20
285478792658Nonecode51Providing gun metal pillar cocks 15mm dia of I class conforming to ISI specifications and ficxing them in position as per direction including cost of all materials and fixtures and conveyance to spot (SR2018-19/P 97/13.80)No271.04271.044.0FalseNoneNoneFalseNoneFalse1084.160
285478892658Nonecode52Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer- in-Charge.(CSR 2023-24/Vol 2 Page no 84/It no11.26.1)Kg154.56154.56710.64FalseNoneNoneFalseNoneFalse109836.51840
285478992658Nonecode53Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent.(Vol 2 page no 63/ item no 9.24)Sqm3226.723226.7244.28FalseNoneNoneFalseNoneFalse142879.16160
285479092658Nonecode54Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (CSR 2023-24 vol I /P -16/2.5.2)Cum13159.3613159.360.99FalseNoneNoneFalseNoneFalse13027.76640
285479192658Nonecode55Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (CSR 2023-24 vol I /P -16/2.5.2)Cum12385.2812385.280.86FalseNoneNoneFalseNoneFalse10651.34080
285479292658Nonecode56Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.CSR2023-24- Vol-I (P-8/item no 2.11 a )Tonne101193.76101193.760.21FalseNoneNoneFalseNoneFalse21250.68960
285479392658Nonecode57Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement: 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. (CSR 2023-24 vol 2 /P -13 /6.3)Cum10038.2710038.274.21FalseNoneNoneFalseNoneFalse42261.11670
285479492658Nonecode58Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.CSR2023-24- Vol-II (99/12.12)Cum140497.3140497.30.06FalseNoneNoneFalseNoneFalse8429.8380
285479592658Nonecode59Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot ressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991.from manufacturer complete as per spcification.SRP- Vol-II (105/12.57.5)-do- 35 mm thick one side teak and one side commercialSqm4408.294408.292.52FalseNoneNoneFalseNoneFalse11108.89080
285479692658Nonecode60Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. CSR-2023-24 Vol-II (41/8.2.1)Sqm333.7333.769.27FalseNoneNoneFalseNoneFalse23115.3990
285479792658Nonecode61Providing 18 mm cement plaster in two coats under layer 12mm thick cement plaster with cement mortar 1:5 (1 cement: 5 coarse sand) and a top layer 6mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand finished rough with sponge to to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge CSR-2023-24 Vol-II Page no 42/8.9)Sqm435.51435.5137.62FalseNoneNoneFalseNoneFalse16383.88620
285479892658Nonecode62Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. CSR2023-24- Vol-II (45/8.25)Sqm154.97154.9769.27FalseNoneNoneFalseNoneFalse10734.77190
285479992658Nonecode63Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge (CSR 2023-24 VOL 2 Page no 46/ It no 8.33.2)Sqm156.11156.1137.62FalseNoneNoneFalseNoneFalse5872.85820
285480092658Nonecode64Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.(Vol 2 Page no 54 / It no 8.79)Rmtr45.2545.2525.0FalseNoneNoneFalseNoneFalse1131.250
285480192658Nonecode65Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (CSR 2023-24 vol 2 /P -77 /11.2)Kg127.83127.83600.0FalseNoneNoneFalseNoneFalse76698.00
285480292658Nonecode66Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by ngineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (CSR 2023-24-Vol 2/ Page no. 26/It no.7.38)Sqm642.52642.5230.0FalseNoneNoneFalseNoneFalse19275.60
17091870820000NoneNoneRoadsLandscapping and Water supply arrangements859049.3
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
285480392659Nonecode01Aligning in the planting area along the contours & marking for pit (without staking) Vol 8 /12/2.8aCum0.560.56400.0FalseNoneNoneFalseNoneFalse224.00
285480492659Nonecode02Digging pits of size 0.75 x 0.75x 0.75m, filling 50% of the pit with top soil and remaining 50% of pit with 1:2:3 proportion of sand (0.035cum) FYM (0.070cum) Red earth (0.105 cum) and planting of well grown tree saplings (excluding cost of plants) ( Vol -8 /48/12.2b)Cum369.6369.6400.0FalseNoneNoneFalseNoneFalse147840.00
285480592659Nonecode03Loading & unloading of Polythene Bagged Seedlings: Loading of polythene-bagged seedlings into the vehicle at the nursery site and unloading at the site nearest to the planting site Seedlings raised in 14" x 20" size bags( Vol -8 /11/2.3f )Nos13.0213.02400.0FalseNoneNoneFalseNoneFalse5208.00
285480692659Nonecode04Transportation: Transportation of polythene-bagged seedlings in hired truck from the nursery site to planting site 14" x 20" size bags( Vol -8 /12/2.4f )Nos8.638.63400.0FalseNoneNoneFalseNoneFalse3452.00
285480792659Nonecode05Conveyance of tall seedlings raised in HDPE bags of size 14" x 20" from the dumping point to the planting site near each pit on head-load, fixing the supporting stake firmly in the pit, planting the tall seedling in the pit tying the seedling to the supporting stake at 3 points (excluding cost of supporting stake) ( Vol -8 /15/2.11f)Nos67.7667.76400.0FalseNoneNoneFalseNoneFalse27104.00
285480892659Nonecode06Planting: Planting of P.B. Seedlings after tearing with blade & removing the polythene bags in trenches / pits including scooping the soil to required depth, pressing the soil gently around the seedlings after planting ( Vol -8 /12/2.6 A/f )No15.2415.24400.0FalseNoneNoneFalseNoneFalse6096.00
285480992659Nonecode07Refilling of trenches, cutting the edges of the excavated trench on the lower side & refilling the trench with 75% of the excavated earth duly breaking the clods & formation of uniformly sloping continuous mound all along the lower side of the trench ( Vol -8 /12/2.7 c )Cum25.3125.31300.0FalseNoneNoneFalseNoneFalse7593.00
285481092659Nonecode08clearing of land by cutting of thick and sparse growth plants(0.25 mt thickness plants and clearing of bushes along with roots( throwing away to 1.5mtr height and 50 mtr far) ( Vol -8 /48/12.1 a)Sqm7.567.561000.0FalseNoneNoneFalseNoneFalse7560.00
285481192659Nonecode09Planting of Shrubs, Digging pits of size 0.45 x 0.45 x0.45m filling 50% of the pit with top soil and remaining 50% of pit with1:2:3 proportion of sand (0.007), FYM (0.014cm) red earth (0.021cm) and and planting of well grown tree saplings (excluding cost of plants) ( Vol -8 /48/12.3b)Nos81.7681.76250.0FalseNoneNoneFalseNoneFalse20440.00
285481292659Nonecode10Planting of Ground cover plants Digging of 1.0mx1.0mx0.45m area and filling 50% of the area with top soiland remaining 50% area with 1:2:3 proportion of sand (0.0375 cum),FYM (0.075 cum) red earth (0.0112 cum) and planting of well grown saplings/plants (excluding cost of plants) ( Vol -8 /48/12.6b)Nos212.8212.8250.0FalseNoneNoneFalseNoneFalse53200.00
285481392659Nonecode11Rose garden/growing of rose plants Digging pits of 0.6x 0.6 x0.6m size and filling 50% of the pit with top soil and remaining 50% of pit with 1:6:6 proportion of sand (0.008), FYM (0.048cm) red earth (0.048cm), Neem oil cake (200 gram), Bone meal (100gram), Gingali oil (100gram),Suphala (10 gms), Rose mix (5 gms) and other plant protection chemicals and planting of different varieties of rose plants etc. (excluding cost of plants) ( Vol -8 /48/12.6b)Nos383.04383.0498.0FalseNoneNoneFalseNoneFalse37537.920
285481492659Nonecode12Growing of Hedges Digging trench of size 1mx0.30mx0.45m and filling 50% of the trench with top soil and remaining 50% trench with1:2:3 proportion of sand (0.0112), FYM (0.0224cum) red earth (0.0336cum) and planting of well grown plants (excluding cost of plants) ( Vol -8 /49/12.9b)Rmtr119.84119.84200.0FalseNoneNoneFalseNoneFalse23968.00
285481592659Nonecode13Supply of inputs such as sand, FYM, Red earth in 1:3:6 ratio.mixing and spreadingthe mixture to 7.50cm thickness wherever required red soil ,farm yard manure & Sand ( Vol -8 /49/12.10 E))Cum121.97121.97150.0FalseNoneNoneFalseNoneFalse18295.50
285481692659Nonecode14Procurement of quality lawn grass (a) Bermuda Gras ( Vol -8 /49/12.10 G A)Sqm112.0112.01000.0FalseNoneNoneFalseNoneFalse112000.00
285481792659Nonecode15Procurement of quality lawn grass (a) Mexican Grass ( Vol -8 /49/12.10 G CSqm224.0224.0400.0FalseNoneNoneFalseNoneFalse89600.00
285481892659Nonecode16Labour Charges mixing Inputs as per prescribed proportion and quantity and spreading, applying fertilizers,digging, levelling , and dibbling with lawn grass at a spacing of 5cm x5cm & as per the direction of the Officer in charge of the work. ( Vol -8 /49/12.10 h)Sqm63.0363.032000.0FalseNoneNoneFalseNoneFalse126060.00
285481992659Nonecode17Providing and fixing chorinated poly venyl chloride(CPVC) pipes having thermal stability for hot & cold water supply including all CPVC plain and brass threaded fittings this includes jointing of pipes and fittings of joints complete as per Engineer in charge. Internal work, exposed on wall. 40 mm nominal OD pipes (CSR 2023-24-Vol.2 Pg122/Ino 13.31.5)Rmtr600.32600.32101.0FalseNoneNoneFalseNoneFalse60632.320
285482092659Nonecode18Providing and fixing chorinated poly venyl chloride(CPVC) pipes having thermal stability for hot & cold water supply including all CPVC plain and brass threaded fittings this includes jointing of pipes and fittings of joints complete as per Engineer in charge. Internal work, exposed on wall. 25 mm nominal OD pipes (CSR 2023-24-Vol.2 Pg122/Ino 13.31.3)Rmtr356.16356.16120.0FalseNoneNoneFalseNoneFalse42739.20
285482192659Nonecode19Providing and fixing chorinated poly venyl chloride(CPVC) pipes having thermal stability for hot & cold water supply including all CPVC plain and brass threaded fittings this includes jointing of pipes and fittings of joints complete as per Engineer in charge. Internal work, exposed on wall. 20 mm nominal OD pipes (CSR 2023-24-Vol.2 Pg122/Ino 13.31.2)Mtr271.04271.04101.0FalseNoneNoneFalseNoneFalse27375.040
285482292659Nonecode20Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete. 25 mm nominal bore SRP- Vol-II (115/13.5.3)Nos430.08430.0815.0FalseNoneNoneFalseNoneFalse6451.20
285482392659Nonecode21Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) 40 mm nominal bore SRP- Vol-II (115/13.4.3)Nos762.72762.724.0FalseNoneNoneFalseNoneFalse3050.880
285482492659Nonecode22Providing and fixing brass stop cock of approved quality 20 mm nominal bore SRP- Vol-II (115/13.3.2)Nos386.4386.425.0FalseNoneNoneFalseNoneFalse9660.00
285482592659Nonecode23Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, griding the edge to half/full round wherever required, labour, curing complete as per specification. (SRP - Vol. 2/65/9.40)No1275.681275.6818.0FalseNoneNoneFalseNoneFalse22962.240
17091870820000NoneNoneRoadsFurniture1005277.9
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
285482692660Nonecode01Executive chairs-mid back: the seat assembly shall be made up of 1.2cm thick hot pressed plywood, upholstered with fabric upholstery covers and moulded polyurethane foam. The seat size shall be 47cm(W)x 48(D). The black assembly shall be made of powder coated tabular frame of diameter 2.54cm. MS ERW tube designed with contoured lumbar support for extra support.the back shall be upholstred with net fabric, the 46.5(W)x 64.5(H). the one piece armrests shall be injection moulded from black co-polymer polypropylene. the pneumatic heigh adjustment shall have an adjustment of 11cm. the pedestal shall be injection moulded in black (RTO Gadag APPORVED RATE)No7180.297180.2915.0FalseNoneNoneFalseNoneFalse107704.350
285482792660Nonecode02Office table -Table of size 1199Wx590Dx735H (mm) shall be made up of 18mm pre-laminated board duly sealed with 2,, PVC beading on all sides. Under stru cture shall be made up of C frame with CRCA MS sheet of 0.9mm thick, tabu lar frame of MS ERW round tube of Dia 25.4mmx1.2mm thick, Modesty panel shall be made up ofn 1mm thick CRCA MS sheet of overall size 355.5W x559Dx 433.5H(mm). make : Godrej/ Featherlitr/ Durain ((RTO Gadag APPORVED RATE)No11370.011370.05.0FalseNoneNoneFalseNoneFalse56850.00
285482892660Nonecode03Library table- Table of without drawer. Table of size 1800x940x740mm. The work top of the table shall be mad up of 25mm thick PLB top with 2mm thick PVC edge beading. Understructure of the table shall be made up of 1.6mm thick MS C frame supporting the top. legs are made up of dia 38.1x1.6mm thick MS ERW tube. ((RTO Gadag APPORVED RATE)No10076.010076.02.0FalseNoneNoneFalseNoneFalse20152.00
285482992660Nonecode04Reception chair - 3 Seater chair cross beam: it shall be made of black -powder coated rectangular M.S ERW tube for better support and load carrying ability.(8+-0.3cmx4+-0.3cmx0.2+-0.16cm) leg and armrest; chrome plated made of cold rolled steel with .12+-0.013 cm for long life and aesthetics. Seat back shell: it shall be powder coated perforated shell made from CRCA MS sheet 0.15+-0.13cm thickness. the side bar shall be made of chrome plated solid steel 3+-x0.3cmx1.2+-0.3 cm with fluting and plastic inserts. the shell shall be assembled on the cross beam with help of M8 bolts. Stain resistant leather cloth and chrome plated surface for enhanced aesthetic life of the product. ((RTO Gadag APPORVED RATE)No26385.3826385.3810.0FalseNoneNoneFalseNoneFalse263853.80
285483092660Nonecode05Table set ( Main table & side return table) main desk of size: 1800x900x750mm. The table top shall be made up of 65 mm thick MDF+ veneer+PU coating of 1.5 hardness. The modesty panel of size:1640x600x16mm, shall be made up of MDF+veneer+PU coating of 1.5 hardness. mobile pedestal of size: 510Wx635Hx445D mm shall be made up of MDF++veneer+PU coating of 1.5 hardness. side unit of size 1200 wx445 D x 660H shall be made up of MDF++veneer+PU coating of 1.5 hardness. make Godrej/Featherlite/Durian (RTO Gadag APPORVED RATE)No60239.560239.52.0FalseNoneNoneFalseNoneFalse120479.00
285483192660Nonecode06Officers Chair the seat shall be made up of insert moulded , polyurethane foam upholstered with foam laminated mesh fabric. The insert moulded foam shall be assembled over a load bearing plastic seat cover. The seat shall be made of plywood and upholstrered with moulded polyurethane foam and foam laminated mesh fabric. the back shall be made up of two piece injection moulded frame. the inner frame shall beupholstrered with mesh fabric and moulded on the main assembly. the chair should be size: 76cm W x 76cmdx117-131cm H. the mechanism shall be designed to have features like 360 degree revolving type , singlr point control, front pivot for tilt with feet resting on ground ensuring more comfort, tilt tension adjustment and 3 position locking with anti-shock feature. Adjustable neck rest assembly shall be made of polyurethance foam upholstrered with foam laminated mesh fabric. the neck rest assembly shall be mounted on the top of the back and should be adjustable up to 45 mm up-down. pedestal shall be made of Die cast aluminium fitted with 5 nos twin wheel castors shall be injection moulded in Nylon.make Godrej/Featherlite/Durian (RTO Gadag APPORVED RATE)No24900.024900.03.0FalseNoneNoneFalseNoneFalse74700.00
285483292660Nonecode07Tepoy inside room: 1000 mm (W) x 650 mm (D) x 450 mm (H) with paper lamination + MDF Board + Toughened glass make Godrej/Featherlite/Durian (RTO Gadag APPORVED RATE)No13706.7913706.792.0FalseNoneNoneFalseNoneFalse27413.580
285483392660Nonecode08Steel Filling cabinets for office 4 Drawer Vertical: width: 470mm Height:1320mm Depth:620mm Rigid knock down construction. CRCA:0.7 mm thick (Top,side & Drawer Front); 0.6 mm thick (Frames, drawer bottom). Eassy to grip full length handle recess integrated into metal drawer fronts . snap on type plastic lable holder on drawer fronts.centralized locking with 10 lever cam lock & having anti-tipping arrangement to ensure that when one drawer is opened for use it does not allow other drawers to be opened. high quality precision ball slide. drawer load: 40kg UDL for 75,000 cycles (BS) high quality precision ball slide.drawer load 40 kg udl for 75,000 cycles (BS) finish:Epoxy polyester powder coated to the thickness of 50 microns (+-10). Make Godrej/Featherlite/Durian (RTO Gadag APPORVED RATE)No18397.8618397.863.0FalseNoneNoneFalseNoneFalse55193.580
285483492660Nonecode09Steel filling cabinets for office 2 drawer vertical:width:470mm Height:710mm Depth:620mm, rigid knock down construction CRCA: 0.7mm thick (Top, side & drawer front) 0.6 mm thick (frames,drawer-inside cover side back side) 0.5mm thick (back, bottom,drawer bottom)eassy togrip full length handle recess integrated into metal drawer fronts. snap on type palastic lable holder on drawer fronts. centralized locking with 10 lever cam lock & having anti-tipping arranement to ensure that when one drawer is opened for use, its does not allow other drawers to be opened.High quqlity precision ball slide. drawer load: 40kg.UDL for 75,000 cycles (BS). Finish: Epoxy polyester powder coated to the thickness of 50 microns (+-10).Make Godrej/Featherlite/Durian (RTO Gadag APPORVED RATE)No11934.3311934.333.0FalseNoneNoneFalseNoneFalse35802.990
285483592660Nonecode10ALMIRAH FOR STORE: 765MM (w) X 440 MM (d) X 1270 * MM (H). Welded construction. 0.8 mm thk CRCA for shelf & 0.9 mm thk CRCA for all other components. 3 way locking mechanisum with shooting bolt. Height wise adjustable shelves 3 nos. uniformly distributed load capacity per full shelf is 80 kg maximum. expoy polyester powder coated to the thickness of 50 microns (+/-10). M10 screw type leveler with hex plastic base.Make Godrej/Featherlite/Durian(RTO Gadag APPORVED RATE)No15251.415251.410.0FalseNoneNoneFalseNoneFalse152514.00
285483692660Nonecode11Magnetic White board of 10 ' x 4' size suitable for use in Classroom (RTO Gadag APPORVED RATE)No6292.926292.925.0FalseNoneNoneFalseNoneFalse31464.60
285483792660Nonecode12STRAIGHT WORKSTATION (Frame and separator) Providing and fixing STRAIGHT WORKSTATION consisting of back to back unit made out of 75 mm thick MS CRCA powder coated ,tile based system for main sprine, Separator 25 mm tghick PLPB-BSL wooden separator for return spine,Top tile finish 8 mm thick MDF covered with Fabric of approved colour and one writing board ( 600 mmw) and one soft board ( 600 mmw ) per workstation,Bottom tile finish 9 mm thick Laminate tile of approved colour, Raceway- one middle raceway ( 600mmW ) below table top per workstation and continous raceway at the skirting level,Wir e manager- ABS plastic grommet one number per table,Table top - 25 mm thick PLPB with straight table top Hardware- MS powder coated corner bkt, cantilever bkt, separator hook on bkt, L bkt and Table joint plate., as per specifications , drawings and as directed by Engineer in charge: Non Sharing workstation 1C) Size : 1200 mmW x 600mm D x1200 mm ht (Non Sharing-Edge binding table top): single unit (P 323/39.14.3)No11830.011830.05.0FalseNoneNoneFalseNoneFalse59150.00
17091870820001NoneNoneRoadsVechicle Parking Shelter784666.89
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
285483892661Nonecode01Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. CSR-2023-24- Vol-I (5/1.4.1)Cum271.04271.0434.47FalseNoneNoneFalseNoneFalse9342.74880
285483992661Nonecode02Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. (SRP -2023-24-Vol 1 Page no 7/It no 1.8)Cum530.88530.8827.0FalseNoneNoneFalseNoneFalse14333.760
285484092661Nonecode03Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M7.5) Using 40 mm nominal size graded crushed coarse aggregates (CSR 2023-24 vol I /P -15 /2.1.2)Cum5833.925833.9212.32FalseNoneNoneFalseNoneFalse71873.89440
285484192661Nonecode04Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand). (CSR-2023-24 -Vol 2/Page no 9/It no 5.1.1)Cum6284.326284.328.51FalseNoneNoneFalseNoneFalse53479.56320
285484292661Nonecode05Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separatelyM25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Vol 1/ Page no 67/It no 2.2.2.1)Cum7309.217309.2116.69FalseNoneNoneFalseNoneFalse121990.71490
285484392661Nonecode06Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.CSR2023-24- Vol-I (P-8/item no 2.11 a )Tonne100191.84100191.841.17FalseNoneNoneFalseNoneFalse117224.45280
285484492661Nonecode07Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(item no 11.2). (Vol 2/ Page no75/It no11.2)Kg126.56126.562700.0FalseNoneNoneFalseNoneFalse341712.00
285484592661Nonecode08Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by ngineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (CSR 2023-24-Vol 2/ Page no. 26/It no.7.38)Sqm636.16636.1686.0FalseNoneNoneFalseNoneFalse54709.760
17091870820000NoneNoneRoadsRCC Slab Culvert524183.88
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
285484692662Nonecode01Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. CSR-2023-24- Vol-I (5/1.4.1)Cum271.04271.0445.0FalseNoneNoneFalseNoneFalse12196.80
285484792662Nonecode02Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M7.5) Using 40 mm nominal size graded crushed coarse aggregates (CSR 2023-24 vol I /P -15 /2.1.2)Cum6343.686343.684.5FalseNoneNoneFalseNoneFalse28546.560
285484892662Nonecode03Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separatelyM25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Vol 1/ Page no 67/It no 2.2.2.1)Cum7309.217309.216.0FalseNoneNoneFalseNoneFalse43855.260
285484992662Nonecode04Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep oles wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (CSR 2023-24-VOL-1-P no.15/It no 2.3.2). For Culvert wallCum9797.769797.7610.35FalseNoneNoneFalseNoneFalse101406.8160
285485092662Nonecode05Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (CSR 2023-24-Vol 1 Page no 16/ 2.5.2)Cum13029.0713029.077.5FalseNoneNoneFalseNoneFalse97718.0250
285485192662Nonecode06Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.CSR2023-24- Vol-I (P-8/item no 2.11 a )t100191.84100191.842.4FalseNoneNoneFalseNoneFalse240460.4160
17091870820001NoneNoneRoadsElectrification works4298934.77
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
285485292663Nonecode01Internal Wiring: Open Conduit System Supplying heavy gauge PVC conduit pipe 19/20mm dia 2 mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. Make:VIP/Avonplast/Finolex. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 2 of 105, 47/1.1.1Rmtr77.2877.28285.0FalseNoneNoneFalseNoneFalse22024.80
285485392663Nonecode02Internal Wiring: Open Conduit System Supplying heavy gauge PVC conduit pipe 25mm dia 2 mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. Make:VIP/Avonplast/Finolex. 25mm dia 2 mm thick. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 2 of 105, 47/1.1.2Rmtr90.7290.72225.0FalseNoneNoneFalseNoneFalse20412.00
285485492663Nonecode03Internal Wiring: Open Conduit System Supplying heavy gauge PVC conduit pipe 32mm dia 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. Make:VIP/Avonplast/Finolex. 32mm dia 2.5 mm thick. CSR 2023-24, Volume-6, Part-III, Utilization, SRP 2 of 105, 47/1.1.3Rmtr118.72118.7275.0FalseNoneNoneFalseNoneFalse8904.00
285485592663Nonecode04Internal Wiring: Open Conduit System Supplying heavy gauge PVC conduit pipe 40mm dia 2.5mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. Make:VIP/Avonplast/Finolex. 40 mm dia 2.5 mm thick. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 2 of 105, 47/1.1.4m166.88166.8850.0FalseNoneNoneFalseNoneFalse8344.00
285485692663Nonecode05Concealed Conduit System: Supplying heavy gauge PVC conduit pipe 19/20 mm dia 2 mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. Make:VIP/Avonplast/Finolex. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 2 of 105, 47/1.2.1m73.9273.92200.0FalseNoneNoneFalseNoneFalse14784.00
285485792663Nonecode06Concealed Conduit System: Supplying heavy gauge PVC conduit pipe 19/20mm dia 2 mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. 25mm dia 2 mm thick. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 2 of 105, 47/1.2.2m87.3687.36175.0FalseNoneNoneFalseNoneFalse15288.00
285485892663Nonecode07Concealed Conduit System: Supplying heavy gauge PVC conduit pipe 19/20mm dia 2 mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. 32mm dia 2.5 mm thick. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 2 of 105, 47/1.2.3m115.36115.3650.0FalseNoneNoneFalseNoneFalse5768.00
285485992663Nonecode08Supplying heavy gauge PVC Conduit Pipe 20mm dia mm 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. Make:VIP/Avonplast/Finolex. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 2 of 105, 47/1.3.1m76.1676.1650.0FalseNoneNoneFalseNoneFalse3808.00
285486092663Nonecode09Supplying heavy gauge PVC Conduit Pipe 25mm dia mm 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 25mm dia 2 mm thick. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 2 of 105, 47/1.3.2m88.4888.48150.0FalseNoneNoneFalseNoneFalse13272.00
285486192663Nonecode10Supplying heavy gauge PVC Conduit Pipe 32mm dia mm 2.5mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 32mm dia 2.5 mm thick. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 2 of 105, 47/1.3.3m110.88110.88125.0FalseNoneNoneFalseNoneFalse13860.00
285486292663Nonecode11Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm etc. as required.25mm. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 3 of 105, 47/1.8.2m39.239.2300.0FalseNoneNoneFalseNoneFalse11760.00
285486392663Nonecode12Supplying PVC flexible conduit pipe 20 mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 3 of 105, 1.9.1m21.2821.2850.0FalseNoneNoneFalseNoneFalse1064.00
285486492663Nonecode13Supplying PVC flexible conduit pipe 25mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely. 25mm. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 3 of 105, 1.9.2m24.6424.6450.0FalseNoneNoneFalseNoneFalse1232.00
285486592663Nonecode14Supplying PVC flexible conduit pipe 32mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely. 32mm. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 3 of 105, 1.9.3m32.4832.4825.0FalseNoneNoneFalseNoneFalse812.00
285486692663Nonecode15Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Wire make:Finolex/V-Gaurd/Polycab/Anchor FRLS/Havells/KEI/Salzer. Short Point Upto 3m from tapping point to out let via switch. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 5 of 105, 2.2.1Point301.28301.2825.0FalseNoneNoneFalseNoneFalse7532.00
285486792663Nonecode16Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Wire make:Finolex/V-Gaurd/Polycab/Anchor FRLS/Havells/KEI/Salzer. Medium point above 3m upto 6 mtr from tapping point to outlet via switch box. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 5 of 105, 2.2.2Point424.48424.4840.0FalseNoneNoneFalseNoneFalse16979.20
285486892663Nonecode17Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Wire make:Finolex/V-Gaurd/Polycab/Anchor FRLS/Havells/KEI/Salzer. Long point above 6m upto 10m from tapping point to out let via switch box. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 5 of 105, 2.2.3Point621.6621.640.0FalseNoneNoneFalseNoneFalse24864.00
285486992663Nonecode18Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm. Wire make:Finolex/V-Gaurd /Polycab /Anchor FRLS /Havells /KEI/Salzer. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 5 of 105, 2.3.2m29.1229.121200.0FalseNoneNoneFalseNoneFalse34944.00
285487092663Nonecode19Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 Sqmm Wire. make:Finolex/V-Gaurd/Polycab/Anchor /Havells / KEI /Salzer. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 5 of 105, 2.3.3m47.0447.041400.0FalseNoneNoneFalseNoneFalse65856.00
285487192663Nonecode20Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 Sqmm Wire. make:Finolex/V-Gaurd/Polycab/Anchor/Havells /KEI/Salzer. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 5 of 105, 2.3.4m70.5670.562000.0FalseNoneNoneFalseNoneFalse141120.00
285487292663Nonecode21Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 Sqmm Wire. make:Finolex/V-Gaurd /Polycab/Anchor /Havells /KEI /Salzer. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 5 of 105, 2.3.5m103.04103.04100.0FalseNoneNoneFalseNoneFalse10304.00
285487392663Nonecode22Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 16 Sqmm Wire. make:Finolex/V-Gaurd /Polycab/Anchor /Havells / KEI /Salzer. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 5 of 105, 2.3.7m356.16356.1650.0FalseNoneNoneFalseNoneFalse17808.00
285487492663Nonecode23Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 1-2 way. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 8 of 105, 3.4.1Each154.56154.5620.0FalseNoneNoneFalseNoneFalse3091.20
285487592663Nonecode24Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 4-5 Way. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 8 of 105, 3.4.3Each198.24198.2414.0FalseNoneNoneFalseNoneFalse2775.360
285487692663Nonecode25Supplying and flush mounting powder coated /galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 6 Way. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 8 of 105, 3.4.4Each246.4246.414.0FalseNoneNoneFalseNoneFalse3449.60
285487792663Nonecode26Supplying and flush mounting powder coated /galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 8 Way. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 8 of 105, 3.4.5Each404.32404.3212.0FalseNoneNoneFalseNoneFalse4851.840
285487892663Nonecode27Supplying and flush mounting powder coated /galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 10-12 Way. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 8 of 105, 3.4.6Each357.28357.2820.0FalseNoneNoneFalseNoneFalse7145.60
285487992663Nonecode28Supplying and flush mounting powder coated /galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 16 Way. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 8 of 105, 3.4.7Each406.56406.5616.0FalseNoneNoneFalseNoneFalse6504.960
285488092663Nonecode29Supplying and flush mounting powder coated /galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 18 Way. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 8 of 105, 3.4.8Each453.6453.620.0FalseNoneNoneFalseNoneFalse9072.00
285488192663Nonecode30Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 module. Make: Anchor/GM/Cona/Salzer/Lisha. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 8 of 105, 3.5.1Each153.44153.4414.0FalseNoneNoneFalseNoneFalse2148.160
285488292663Nonecode31Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module. Make: Anchor/GM/Cona/Salzer/Lisha. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 8 of 105, 3.5.3Each196.0196.014.0FalseNoneNoneFalseNoneFalse2744.00
285488392663Nonecode32Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module. Make: Anchor/GM/Cona/Salzer/Lisha. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 8 of 105, 3.5.4Each262.08262.0812.0FalseNoneNoneFalseNoneFalse3144.960
285488492663Nonecode33Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module. Make: Anchor/GM/Cona/Salzer/Lisha. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 8 of 105, 3.5.5Each318.08318.0816.0FalseNoneNoneFalseNoneFalse5089.280
285488592663Nonecode34Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12Module. Make: Anchor/GM/Cona/Salzer/Lisha. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 8 of 105, 3.5.6Each385.28385.2816.0FalseNoneNoneFalseNoneFalse6164.480
285488692663Nonecode35Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 16 Module. Make: Anchor/GM/Cona/Salzer/Lisha. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 8 of 105, 3.5.7Each444.64444.64150.0FalseNoneNoneFalseNoneFalse66696.00
285488792663Nonecode36Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 18 Module. Make: Anchor/GM/Cona/Salzer/Lisha. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 8 of 105, 3.5.8Each511.84511.844.0FalseNoneNoneFalseNoneFalse2047.360
285488892663Nonecode37Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6 A One way Switch. Make: Anchor/GM/Cona/Salzer/Lisha. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 9 of 105, 3.6.1Each114.24114.24140.0FalseNoneNoneFalseNoneFalse15993.60
285488992663Nonecode38Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6 A Three Way Socket. Make: Anchor/GM/Cona/Salzer/Lisha. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 9 of 105, 3.6.3Each191.52191.5220.0FalseNoneNoneFalseNoneFalse3830.40
285489092663Nonecode39Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. Make: Anchor/GM/Cona/Salzer/Lisha. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 9 of 105, 3.6.4Each399.84399.8450.0FalseNoneNoneFalseNoneFalse19992.00
285489192663Nonecode40Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16 A One Way Switch. Make: Anchor/GM/Cona/Salzer/Lisha. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 9 of 105, 3.6.7Each201.6201.620.0FalseNoneNoneFalseNoneFalse4032.00
285489292663Nonecode41Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32 A D.P. Switch. Make: Anchor/GM/Cona/Salzer/Lisha. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 9 of 105, 3.6.9Each365.12365.1230.0FalseNoneNoneFalseNoneFalse10953.60
285489392663Nonecode42Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16 A Universal Socket. Make: Anchor/GM/Cona/Salzer/Lisha. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 9 of 105, 3.6.10Each264.32264.3230.0FalseNoneNoneFalseNoneFalse7929.60
285489492663Nonecode43Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. R J 45/I.O.Out let Cat-6 Make: Anchor/GM/Cona/Salzer/Lisha. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 9 of 105, 3.6.12Each377.44377.44225.0FalseNoneNoneFalseNoneFalse84924.00
285489592663Nonecode44Extra for supplying 4 mm thick white plastic plate and covering for junction boxes of size 110 mm conduit using necessary machine screws. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 9 of 105, 3.10.3Each23.5223.5245.0FalseNoneNoneFalseNoneFalse1058.40
285489692663Nonecode45Supplying And fixing of 6 A electrical accessories on existing switch board. 6 A Ceilling Rose. Make: Anchor/GM/Cona/Salzer/Lisha. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 10 of 105, 3.14.5Each87.3687.3636.0FalseNoneNoneFalseNoneFalse3144.960
285489792663Nonecode46Supplying And fixing of 6 A electrical accessories on existing switch board. 6 A Batten Holder. Make: Anchor/GM/Cona/Salzer/Lisha. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 10 of 105, 3.14.7Each82.8882.8875.0FalseNoneNoneFalseNoneFalse6216.00
285489892663Nonecode47Lumiairs & Light Fixtures & Accessories: Supplying of 1 X 4' feet 36/40 W PVC Batten with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. Make: Philips /Bajaj / Crompton /Havells /Wipro. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 43 of 105, 11.3.3Each1421.281421.2830.0FalseNoneNoneFalseNoneFalse42638.40
285489992663Nonecode48Supplying of recess mounting non integrated type LED down light 10-12 W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clA, LED of Power/COB with CCT 6500 degree K, CRIgreater than 70%. efficacy greater than 100 lumen per W, 120degree beam spread, lifegreater than 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED's are driven by HF electronic driver integrated in a separate control gear assembly., with PF greater than 0.95, power loss shouldsnaller than 5% of lamp Wage, short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 10-12 W. Make: Philips/Bajaj/Crompton/Havells/Wipro. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 44 of 105, 11.4.2Each1421.281421.2810.0FalseNoneNoneFalseNoneFalse14212.80
285490092663Nonecode49Supplying of recess mounting non integrated type LED down light 10-12 W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clA, LED of Power/COB with CCT 6500 degree K, CRIgreater than 70%. efficacy greater than 100 lumen per W, 120degree beam spread, lifegreater than 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED's are driven by HF electronic driver integrated in a separate control gear assembly., with PF greater than 0.95, power loss shouldsnaller than 5% of lamp Wage, short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition 15-18 Watts LED down light . Make: Philips/Bajaj/Crompton/Havells. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 44 of 105, 11.4.3Each1871.521871.528.0FalseNoneNoneFalseNoneFalse14972.160
285490192663Nonecode50Supplying of recess mounting non integral type LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clA, Power LEDs with CCT 6500 degree K, CRIgreater than 70%. efficacy greater than 100 lumen per W, 120degree beam spread, lifegreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF greater than 0.95, power loss shouldsnaller than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED Modular down light 1'X1' 24 W. Make: Philips/Bajaj/Crompton/Havells. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 44 of 105, 11.6.2No4135.044135.0420.0FalseNoneNoneFalseNoneFalse82700.80
285490292663Nonecode51Supplying of recess mounting non integral type LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clA, Power LEDs with CCT 6500 degree K, CRIgreater than 70%. efficacy greater than 100 lumen per W, 120degree beam spread, lifegreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF greater than 0.95, power loss shouldsnaller than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED Modular down light 2' X 2', 40-42 Watts. Make: Philips/Bajaj/Crompton/Havells/Wipro. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 45 of 105, 11.6.4Each5444.325444.324.0FalseNoneNoneFalseNoneFalse21777.280
285490392663Nonecode52Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiencygreater than 1301m/w, nominal CRI greater than 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect. 120 Watts. Make: Philips/Bajaj/Crompton/Havells/Wipro. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 45-46 of 105, 118.5Each11267.211267.28.0FalseNoneNoneFalseNoneFalse90137.60
285490492663Nonecode53Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiencygreater than 1301m/w, nominal CRI greater than 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect LED Flood light 70 Watts. Make: Philips/Bajaj/Crompton/Havells/Wipro. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 46 of 105, 11.9.1Each8276.88276.82.0FalseNoneNoneFalseNoneFalse16553.60
285490592663Nonecode54Supplying and Fixing of 32 mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 56 of 105, 13.1.2Each1010.241010.248.0FalseNoneNoneFalseNoneFalse8081.920
285490692663Nonecode55Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 56 of 105, 13.5Each211.68211.6810.0FalseNoneNoneFalseNoneFalse2116.80
285490792663Nonecode56Supplying of exhaust fan 1440 rpm 300 mm (12") Size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Make:Bajaj /Orient / Almonard /Usha /Crompton. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 30 of 105, 6.1Each1727.041727.042.0FalseNoneNoneFalseNoneFalse3454.080
285490892663Nonecode57Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48" Sweep (1200mm Regular). Make:Bajaj /Orient /Almonard / Usha/Crompton. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 30 of 105, 6.3.1Each2335.22335.210.0FalseNoneNoneFalseNoneFalse23352.00
285490992663Nonecode58Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. On Wall/Ceiling/Rafter/Girders. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 56 of 105, 13.7.1Each133.28133.28134.0FalseNoneNoneFalseNoneFalse17859.520
285491092663Nonecode59Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 57 of 105, 13.10Each181.44181.4412.0FalseNoneNoneFalseNoneFalse2177.280
285491192663Nonecode60Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 57 of 105,13.14Each483.84483.842.0FalseNoneNoneFalseNoneFalse967.680
285491292663Nonecode61Fixing all types and all capacities of 1'x4' / 2'x2' LED Light fittings indoor on the wall / ceiling / rafters / girders with necessary supporting frame, using 2310.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 58 of 105,13.19Each544.32544.3230.0FalseNoneNoneFalseNoneFalse16329.60
285491392663Nonecode62Control Switch Gears & Accessories: Fabricating supplying and mounting MS box made out 16 SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 20 of 105, 5.42.2Sq CM0.430.43225000.0FalseNoneNoneFalseNoneFalse96750.00
285491492663Nonecode63Supplying 100 A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100 Amps 4X30X6mm Aluminium Strips. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 20 of 105, 5.40.1m2479.682479.684.0FalseNoneNoneFalseNoneFalse9918.720
285491592663Nonecode64Supplying 100 A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250 A 4 X 30 X 10mm Aluminium Strips. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 20 of 105, 5.40.2m3447.363447.362.0FalseNoneNoneFalseNoneFalse6894.720
285491692663Nonecode65Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.40 X 40 X 6mm. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 20 of 105, 5.41.1m308.0308.085.0FalseNoneNoneFalseNoneFalse26180.00
285491792663Nonecode66Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 75 X 75 X 6 mm angle iron frame work. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 20 of 105, 5.41.3m556.64556.6450.0FalseNoneNoneFalseNoneFalse27832.00
285491892663Nonecode67Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 19 of 105, 5.38Each519.68519.6816.0FalseNoneNoneFalseNoneFalse8314.880
285491992663Nonecode68Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 19 of 105, 5.34Each565.6565.616.0FalseNoneNoneFalseNoneFalse9049.60
285492092663Nonecode69Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 19 of 105, 5.33Each9374.49374.44.0FalseNoneNoneFalseNoneFalse37497.60
285492192663Nonecode70Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 A three phase 4 wire whole current class-1 Accuracy Energy Meter. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 19 of 105, 5.35Each5740.05740.02.0FalseNoneNoneFalseNoneFalse11480.00
285492292663Nonecode71Supplying, fixing and wiring 3 Phase Digital Ammeter /Voltmeter. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 19 of 105, 5.29Each1433.61433.66.0FalseNoneNoneFalseNoneFalse8601.60
285492392663Nonecode72Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 18 of 105, 5.21Each9313.929313.921.0FalseNoneNoneFalseNoneFalse9313.920
285492492663Nonecode73Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 100 Amps 25kA.Four Pole. Make: L&T/Sneider /Legrand/Havlls. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 17 of 105, 5.15.9Each9256.89256.86.0FalseNoneNoneFalseNoneFalse55540.80
285492592663Nonecode74Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 125 A 25kA Four Pole MCCB. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 17 of 105, 5.15.10Each11280.6411280.644.0FalseNoneNoneFalseNoneFalse45122.560
285492692663Nonecode75Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6 - 32 Amps.SP. Make: L&T/Sneider/Legrand/ Havells. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 17 of 105, 5.18.1Each585.76585.7645.0FalseNoneNoneFalseNoneFalse26359.20
285492792663Nonecode76Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A DP MCB. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 17 of 105, 5.18.4Each1235.361235.3648.0FalseNoneNoneFalseNoneFalse59297.280
285492892663Nonecode77Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 Amps TPN MCB. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 17 of 105, 5.18.7.Each1990.241990.2418.0FalseNoneNoneFalseNoneFalse35824.320
285492992663Nonecode78Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 Amps Utilization, SRP 17 of 105, 5.18.8Each2680.162680.1612.0FalseNoneNoneFalseNoneFalse32161.920
285493092663Nonecode79Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. I- Single door. 8 Way SP & N. Make: L&T/Sneider /Legrand / Havells. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 18 of 105, 5.19.3Each1458.241458.244.0FalseNoneNoneFalseNoneFalse5832.960
285493192663Nonecode80Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. I- Single door 16 Way SP & N MCB distribution boards. Make: L&T/Sneider /Legrand / Havells. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 18 of 105, 5.19.5Each2159.362159.362.0FalseNoneNoneFalseNoneFalse4318.720
285493292663Nonecode81Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. I- Single door 8 Way TP & N .III) Double Door. Make: L&T/Sneider /Legrand / Havells. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 18 of 105, 5.19.13Each4632.324632.321.0FalseNoneNoneFalseNoneFalse4632.320
285493392663Nonecode82L.T.Underground Cables: 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 10SQmm 4 Core. (10 GI Stris-4 X 0.8 mm). Make: Finolex/ Polycab/Havells/KEI. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 13 of 81, 199/32.03.Km166445.44166445.440.3FalseNoneNoneFalseNoneFalse49933.6320
285493492663Nonecode83L.T.Underground Cables: 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 16 SQmm, 4 Core LTUG Cable , (11 GI Strips- 4x 0.8mm) CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 13 of 81, 201/32.05.Km205455.04205455.040.4FalseNoneNoneFalseNoneFalse82182.0160
285493592663Nonecode84L.T.Underground Cables: 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 25 SQmm, 4 Core LTUG Cable , (13 GI Strips- 4x 0.8mm) CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 13 of 81, 204/32.08.Km269710.56269710.560.5FalseNoneNoneFalseNoneFalse134855.280
285493692663Nonecode85L.T.Underground Cables: 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 50 SQmm, 4 Core LTUG Cable , 17 GI Strips- 4x 0.8mm) CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 13 of 81, 208/32.12.Km232057.28232057.280.2FalseNoneNoneFalseNoneFalse46411.4560
285493792663Nonecode86Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. Water Supply & UGD Works CSR 2021-22, Volume-V. SRP 163/40.Each4977.04977.05.0FalseNoneNoneFalseNoneFalse24885.00
285493892663Nonecode87Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, . In Hard Soil. CSR 2021-22,Volume-VI, SRP 8 of 14/ 202-29.03.cm389.0389.0125.0FalseNoneNoneFalseNoneFalse48625.00
285493992663Nonecode88Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff. LT Cable: 2.5 to 25 SQmm. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 52 of 81, 174/21.05.Km18098.0818098.081.15FalseNoneNoneFalseNoneFalse20812.7920
285494092663Nonecode89Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff. LT Cable: 35 to 95 SQMM. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 52 of 81, 175/21.06.Km26484.6426484.641.0FalseNoneNoneFalseNoneFalse26484.640
285494192663Nonecode90Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff. Aluminium End Terminal (Lug)- 10 SQmm size. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 27 of 81, 469/60.01.No3.363.3664.0FalseNoneNoneFalseNoneFalse215.040
285494292663Nonecode91Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff. Aluminium End Terminal (Lug)- 16 SQmm size. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 27 of 81, 470/60.02.No3.363.3636.0FalseNoneNoneFalseNoneFalse120.960
285494392663Nonecode92Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff. Aluminium End Terminal (Lug)- 25 SQmm size. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 27 of 81, 471/60.03.No4.484.4836.0FalseNoneNoneFalseNoneFalse161.280
285494492663Nonecode93Aluminium End Terminal (Lug)-50 SQmm size. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 27 of 81, 473/60.05.No10.0810.0836.0FalseNoneNoneFalseNoneFalse362.880
285494592663Nonecode94PVC Pipe as per IS-2509-100 mm dia. CSR 2021-22,Volume-VI, SRP 15 of 27/392-48.09m256.0256.0100.0FalseNoneNoneFalseNoneFalse25600.00
285494692663Nonecode95PVC Pipe as per IS-2509-150 mm dia. CSR 2021-22,Volume-VI, SRP 15 of 27/393-48.10m534.0534.0125.0FalseNoneNoneFalseNoneFalse66750.00
285494792663Nonecode96Digging of Pit for providing GI Pipe type Earthing. Hard Soil. CSR 2023-24, Volume-6, Part-III, Utilization, SRP 43 of 81, 22 / 1.6.2Per Pit2539.042539.0410.0FalseNoneNoneFalseNoneFalse25390.40
285494892663Nonecode97GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 Kg. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 22 of 81, 389/ 51.01No862.4862.410.0FalseNoneNoneFalseNoneFalse8624.00
285494992663Nonecode98Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 22 of 81, 390 / 51.02No739.2739.210.0FalseNoneNoneFalseNoneFalse7392.00
285495092663Nonecode99Good Quality Salt for grounding purposes packed in 50 Kg gunny bag. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 22 of 81, 391 / 51.03Bag402.08402.0810.0FalseNoneNoneFalseNoneFalse4020.80
285495192663Nonecode100GI Pipe B - Class as per IS-1239-G I Pipe 40mm Dia. CSR 2021-22,Volume-VI, SRP 16 of 27/409 -49.04m295.0295.020.0FalseNoneNoneFalseNoneFalse5900.00
285495292663Nonecode101GI Pipe B - Class as per IS-1239-G I Pipe 63 mm Dia. CSR 2021-22,Volume-VI, SRP 16 of 27/411 -49.06.m415.0415.020.0FalseNoneNoneFalseNoneFalse8300.00
285495392663Nonecode102RCC Hume pipe 2000mm long 200mm dia. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 32 of 81, 578 / 68.02m1293.61293.616.0FalseNoneNoneFalseNoneFalse20697.60
285495492663Nonecode103Collars for RCC Hume pipe 200mm dia. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 32 of 81, 580 / 68.04No115.36115.3616.0FalseNoneNoneFalseNoneFalse1845.760
285495592663Nonecode104Transformer Centre & 11 kV Line Work: Digging of Pit 1.8 Mtr depth for errection of 9 to 10 Mtr Long Steel/RCC/PSCC supports as per approved Drawing. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 43 of 81, 2/1.1.3No1914.081914.0820.0FalseNoneNoneFalseNoneFalse38281.60
285495692663Nonecode105RCC Pole - 9 Mtr Long, 145 Kg WL (Dwg No. BESCOM/GM/QS&S/02 Dtd 24.11.2018) as per IS-785. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 43 of 81, 2/1.1.2No7925.127925.126.0FalseNoneNoneFalseNoneFalse47550.720
285495792663Nonecode106PSCC Pole - 9 Mtr Long, 300 Kg WL (Dwg No. BESCOM/GM/QS&S/55 Dtd 24.11.2018) as per REC Standards. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 43 of 81, 2/1.1.2No4702.884702.8815.0FalseNoneNoneFalseNoneFalse70543.20
285495892663Nonecode107Erection of RCC/PSCC Pole of 9 to 10 Mtr long in a pit of 1.8 Mtr depth. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 44 of 81, 30/2.02No1246.561246.5621.0FalseNoneNoneFalseNoneFalse26177.760
285495992663Nonecode10811 kV, Horizontal Cross Arm - Mild Steel (MS) (Dwg No. BESCOM/GM/QS&S/04 Dtd 24.11.2018). CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 3 of 81, 11/2.01No416.64416.6420.0FalseNoneNoneFalseNoneFalse8332.80
285496092663Nonecode10911 kV, Special 3 Pin Cross Arm - MS (Dwg No. BESCOM/GM/QS&S/03 Dtd 24.11.2018). CSR 2023-24, Volume-6, Part-III ,Utilization, SRP3 of 81, 13/2.03No984.48984.4824.0FalseNoneNoneFalseNoneFalse23627.520
285496192663Nonecode110HT ST Support 50x8 mm Flat - MS (Dwg No. BESCOM/GM/QS&S/04 Dtd 24.11.2018.) CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 4 of 81, 21/2.11No101.92101.9220.0FalseNoneNoneFalseNoneFalse2038.40
285496292663Nonecode111HT ST Support 50x8 mm Flat - MS (Dwg No. BESCOM/GM/QS&S/04 Dtd 24.11.2018.) Spiral Earth Electrode. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 4 of 81, 26/2.16No267.68267.6824.0FalseNoneNoneFalseNoneFalse6424.320
285496392663Nonecode112HT ST Support 50x8 mm Flat - MS (Dwg No. BESCOM/GM/QS&S/04 Dtd 24.11.2018.) Spiral Earth Electrode. 11 kV Ceramic Pin Insulator (Shell only). CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 5 of 81, 47/6.01No92.9692.9648.0FalseNoneNoneFalseNoneFalse4462.080
285496492663Nonecode113HT ST Support 50x8 mm Flat - MS (Dwg No. BESCOM/GM/QS&S/04 Dtd 24.11.2018.) Spiral Earth Electrode. 11 kV GI Pin for 11 kV Ceramic Shell Insulator. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 5 of 81, 48/6.02No73.9273.9248.0FalseNoneNoneFalseNoneFalse3548.160
285496592663Nonecode114HT ST Support 50x8 mm Flat - MS (Dwg No. BESCOM/GM/QS&S/04 Dtd 24.11.2018.) Spiral Earth Electrode. DISC Insulator 45 kN Porcelain. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 5 of 81,55/6.09No571.2571.224.0FalseNoneNoneFalseNoneFalse13708.80
285496692663Nonecode115ACSR Conductor as per IS-398 (Part -2/1996). Rabbit ACSR (6/3.35mm Al + 1/3.35mm St) Std Wt:214 kg/KM. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 5 of 81,59/ 7.02Km51782.0851782.082.0FalseNoneNoneFalseNoneFalse103564.160
285496792663Nonecode116Guy Wire & GI Wire as per IS-2141- 7/10 SWG Guy Wire. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 5 of 81,60/ 8.01MT86493.1286493.120.5FalseNoneNoneFalseNoneFalse43246.560
285496892663Nonecode117Guy Wire & GI Wire as per IS-2141- 8 SWG G I Wire.(4.064 mm Dia), std Wt:125 kg/KM. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 5 of 81,61/ 8.02MT84044.884044.80.25FalseNoneNoneFalseNoneFalse21011.20
285496992663Nonecode118P G Clamp- Rabbit to Rabbit. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 6 of 81,65/ 9.02No114.24114.2424.0FalseNoneNoneFalseNoneFalse2741.760
285497092663Nonecode119Distribution Transformer - 3 Phase, 11kV/433V - Stacked CRGO Core with Oil as per IS-1180 (Part-1): 2014. OPEN BUSHING TYPE: 63 KVA Aluminium Wgd, Star 2 (5 Star). CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 7 of 81, 88/ 12.04No204450.4204450.41.0FalseNoneNoneFalseNoneFalse204450.40
285497192663Nonecode120LT Distribution Box as per IS-13947 Part-1&2- L T Distribution Box for 100 KVA DTC with MCCB's (Sheet metal). CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 9 of 81, 134/ 18.01No25408.3225408.321.0FalseNoneNoneFalseNoneFalse25408.320
285497292663Nonecode121Lightning Arrester as per IEC-60099-4: 9KV Lightening Arrestor Metal Oxide Ceramic type with GROUND DISCONNECTOR. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 9 of 81, 137/ 19.01(Set(3Nos))No1030.41030.41.0FalseNoneNoneFalseNoneFalse1030.40
285497392663Nonecode12211 kV, HG Fuse Unit with Solid Core Insulator (Dwg No. BESCOM/GM/QS&S/21 Dtd 24.11.2018) CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 9 of 81, 139/ 20.01(Set(3Nos))No1197.281197.281.0FalseNoneNoneFalseNoneFalse1197.280
285497492663Nonecode123Double Pole TC Set for erection of Transformer on RCC/PSCC 9 Mtr Long Poles as per IS-1977.For 100/300 KVA 4/5 Star rated Transformer on RCC Pole - 9mtr Long 145kg WL - M S. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 9 of 81, 142/ 21.03Set19490.2419490.242.0FalseNoneNoneFalseNoneFalse38980.480
285497592663Nonecode124GOS as per IS-9921, IS-1977- 11 kV , 200 Amps Single Break GOS. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 11 of 81, 166/ 24.01Set10584.010584.01.0FalseNoneNoneFalseNoneFalse10584.00
285497692663Nonecode125H - Frame Set for fixing 11 kV, 200 Amps Single Break GOS - (For DP structure for providing New GOS for sectionalisation) - MS. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 11 of 81, 171/ 24.06Set4851.844851.841.0FalseNoneNoneFalseNoneFalse4851.840
285497792663Nonecode126Insulated GOS Operating Rods. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 12 of 81, 175/ 24.10No462.56462.561.0FalseNoneNoneFalseNoneFalse462.560
285497892663Nonecode127Erection of Double Pole Transformer Structure using 9 Mtr Long RCC (145 Kg WL)/PSCC (300 Kg WL) Pole including fixing of Structure Materials, Erection of Poles etc., complete for mounting of Transformer as per approved drawing. for 63 to 100 KVA. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 44 of 81, 175/ 38/3.01Per Structure6412.06412.02.0FalseNoneNoneFalseNoneFalse12824.00
285497992663Nonecode128Fixing of V-Shape/Horizontal cross arm for DC Line including Brace and Insulator fixing. (Without Single Top Support). CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 45 of 81, 51/ 5.03Each287.84287.8414.0FalseNoneNoneFalseNoneFalse4029.760
285498092663Nonecode129Fixing of HT/LT Single Top Support. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 45 of 81, 54/ 5.06Each125.44125.4414.0FalseNoneNoneFalseNoneFalse1756.160
285498192663Nonecode130Fixing of GUY Set with break insulator making use of 7/3.15 mm (7/10 SWG) galvanised steel wire with turn buckle and anchoring arrangement as per approved drawing. (Excluding excavation of PIT). CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 45 of 81, 58/ 5.10Per Set297.92297.9212.0FalseNoneNoneFalseNoneFalse3575.040
285498292663Nonecode131Stringing of Conductor- Rabbit ACSR. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 46 of 81, 65/ 6.02 (Per km/Wire)Km4884.324884.322.0FalseNoneNoneFalseNoneFalse9768.640
285498392663Nonecode132Errection of 25 to 63 KVA Transformer on Transformer Structure. Transformer. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 46 of 81, 72/ 8.01Each1336.161336.161.0FalseNoneNoneFalseNoneFalse1336.160
285498492663Nonecode133Fixing DOLO Cutout/Horn Gap Fuse including fixing of cross arm and wiring. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 48 of 81, 96/ 13.01Each265.44265.443.0FalseNoneNoneFalseNoneFalse796.320
285498592663Nonecode134Fixing of GOS including wiring (11 kV Single Break 200 Amps). CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 48 of 81, 97/ 13.02Each1236.481236.481.0FalseNoneNoneFalseNoneFalse1236.480
285498692663Nonecode135Fixing of 3 Nos Lightning Arrestor including wiring. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 48 of 81,101 / 13.06Set133.28133.281.0FalseNoneNoneFalseNoneFalse133.280
285498792663Nonecode136Transportation cable from Store to workplace: L T Cable 2.5 to 25 SQmm. ( Single/3.5/4 Core) CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 51-52 of 81,167 / 20.05 (Per KM of cable)Km1329.441329.441.15FalseNoneNoneFalseNoneFalse1528.8560
285498892663Nonecode13735 to 95 SQmm ( 3.5/4 Core) CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 51-52 of 81,168 / 20.06 (Per KM of cable)Km2671.22671.20.6FalseNoneNoneFalseNoneFalse1602.720
285498992663Nonecode138Laying of cable in Existing Trench /GI Pipe / Stone ware pipe /RCC Hume pipe using Wooden Aluminium Rollers as directed by the departmental staff. LT Cable 2.5 to 25 Sqmm. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 52 of 81,174 / 21.05Km23392.3223392.321.2FalseNoneNoneFalseNoneFalse28070.7840
285499092663Nonecode139Laying of cable in Existing Trench /GI Pipe / Stone ware pipe /RCC Hume pipe using Wooden /Aluminium Rollers as directed by the departmental staff. LT Cable 35 to 95 Sqmm. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 52 of 81,175 / 21.06Km34875.6834875.680.2FalseNoneNoneFalseNoneFalse6975.1360
285499192663Nonecode140Laying of cable in Existing Trench /GI Pipe / Stone ware pipe /RCC Hume pipe using Wooden /Aluminium Rollers as directed by the departmental staff. L.T.Protection Kit. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 9 of 81,133 / 17.01No2265.762265.761.0FalseNoneNoneFalseNoneFalse2265.760
285499292663Nonecode141Laying of cable in Existing Trench /GI Pipe / Stone ware pipe /RCC Hume pipe using Wooden Aluminium Rollers as directed by the departmental staff. Fixing of L.T.Protection Kit. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 49 of 81,115 / 15.03Per Kit398.72398.721.0FalseNoneNoneFalseNoneFalse398.720
285499392663Nonecode142LT 3 Phase 4 Wire 5-30 Amps Thread Through Type composite Meter Housing Box consisting of ETV Meter with AMR comply and LTCT with built in GSM/GPRS Modem (as per technical specification) upto 100 kVA Distribution Transformer. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 23 of 81, 405 / 53.11No20132.020132.01.0FalseNoneNoneFalseNoneFalse20132.00
285499492663Nonecode143Fixing of Thread Through Meter along with Wiring. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 49 of 81,111 / 14.03No3445.123445.121.0FalseNoneNoneFalseNoneFalse3445.120
285499592663Nonecode144Providing chain link fencing 50 mm size of 8 guage properly stretched between rectangular Poles and fixed with suitable bolts & nuts, the free ends shall be welded to the Pole and block pipe at top and bottom as required including cost of all materials, labour, lead and lifts, cutting, bending wherever necessary, wastage and lapping etc., complete as per the direction of the engineer incharge for work including two coats of approved quality paint over one coat of primer paint. CSR 2021-22,Volume-VI, SRP 12 of 14 / 38Sqm987.0987.030.0FalseNoneNoneFalseNoneFalse29610.00
285499692663Nonecode145Submersible Pump set: Providing ,Supplying to work site, Submersible Pump set of 150mm dia suitable for borewell and confirming ti IS 8034-2000 ; 3 Phase,SS Bowl & Impeller with Low volt Motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. For 5 .00 HP -90 LPM @ 110m = 10 STG Out let Dia-2". Make: TEXMO/ Kirloskar /Crompton / SUGUNA. Water Supply & UGD Works CSR 2023-24, Volume-V. SRP 152/13.13.6 .Each35993.4435993.441.0FalseNoneNoneFalseNoneFalse35993.440
285499792663Nonecode146Supply and Delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendmendts. 1X3X4m2. Make: Finolex/Polycab/V-Guard/Havells/Slazer./KEI. Water Supply & UGD Works CSR 2023-24, Volume-V. SRP 154/13.22.3m151.2151.2100.0FalseNoneNoneFalseNoneFalse15120.00
285499892663Nonecode147Supply & delivery at site brand new best make gate valve as per IS 778/1984 with ISI mark and as per its latest amendmdnets. Size-50 mm. Water Supply & UGD Works CSR 2021-22, Volume-V. SRP 54/13.24.1Each1400.01400.01.0FalseNoneNoneFalseNoneFalse1400.00
285499992663Nonecode148Supply & delivery at site brand new best make non-return valve as per IS 778/1984 with ISI mark and as per its latest amendments. Size-50mm. Water Supply & UGD Works CSR 2023-24, Volume-V. SRP 154/13.25.1Each1400.01400.02.0FalseNoneNoneFalseNoneFalse2800.00
285500092663Nonecode149Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL-Direct Online Starter 2) S-D- Star Delta Starter. for Out door. Upto 6 HP. Make:L&T . Water Supply & UGD Works CSR 2023-24, Volume-V. SRP 154-155/ 13.23.2Each10696.010696.01.0FalseNoneNoneFalseNoneFalse10696.00
285500192663Nonecode150Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments. Water Supply & UGD Works CSR 2023-24, Volume-V. SRP 155/13.28m616.0616.075.0FalseNoneNoneFalseNoneFalse46200.00
285500292663Nonecode151Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. Water Supply & UGD Works CSR 2023-24, Volume-V. SRP 155/13.21.Set1736.01736.01.0FalseNoneNoneFalseNoneFalse1736.00
285500392663Nonecode152Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. Water Supply & UGD Works CSR 2023-24, Volume-V. SRP 156/13.32Job7280.07280.01.0FalseNoneNoneFalseNoneFalse7280.00
285500492663Nonecode153Labour charges for erection of outdoor type panel board and meter board units with all necessary materials and labour, tools and equipments including providing cement concrete foundation bed etc., complete as per specification, with testing of as per instructions of engineer incharge of work. Water Supply & UGD Works CSR 2023-24, Volume-V. SRP 156/13.34Job1624.01624.01.0FalseNoneNoneFalseNoneFalse1624.00
285500592663Nonecode154Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. Water Supply & UGD Works CSR 2023-24, Volume-V. SRP 157/13.39Job4200.04200.01.0FalseNoneNoneFalseNoneFalse4200.00
285500692663Nonecode155Supply & delivery of Centrifugal Pumpset at site brand new best make & with discharge duty confirming to ISI standards & its amendmenrs. 3 HP Size 80 X 65 Head 2.50 m discharge 600 LPM .Make: Texmo/ Suguna / Kirloskar / Crompton Water Supply & UGD Works CSR 2023-24, Volume-V. SRP 157/13.40.3Each21073.9221073.921.0FalseNoneNoneFalseNoneFalse21073.920
285500792663Nonecode156Supply and delivery at site brand new best make starter/ control panel suitable for following HP centrifugal pump confirming with ISI mark and its latest amendments. Make:L&T. Water Supply & UGD Works CSR 2023-24, Volume-V. SRP 157/13.43.1Each10640.010640.01.0FalseNoneNoneFalseNoneFalse10640.00
285500892663Nonecode157Supply, delivery, erection and commissioning at site ELCB suitable for monoblock centrifugal pump confirming with ISI mark and its latest amendments. Water Supply & UGD Works CSR 2023-24, Volume-V. SRP 158/13.45Each4611.044611.041.0FalseNoneNoneFalseNoneFalse4611.040
285500992663Nonecode158Supply and delivery at site brand new best make Foot valve suitable for centrifugal pump upto 10HP confirming with ISI mark and its latest amendments. Water Supply & UGD Works CSR 2023-24, Volume-V. SRP 158/13.48Each2464.02464.01.0FalseNoneNoneFalseNoneFalse2464.00
285501092663Nonecode159UPS & Batteries and LAN Wiring: Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 5 KVA ON LINE UPS. Make:TECHSER /LUMINOUS /MICROTEK. BIS Approved make. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 38 of 105, 580 / 9.3.3Each76588.9676588.961.0FalseNoneNoneFalseNoneFalse76588.960
285501192663Nonecode160Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries.100 AH Capacity. Make:Exide/ Amricon/ BIS Approved. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 38 of 105, 580 / 9.4.4Each22548.9622548.966.0FalseNoneNoneFalseNoneFalse135293.760
285501292663Nonecode161Supplying and drawing UTP-CAT 6E LAN cable. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 36 of 105, 580 / 8.1.m42.5642.56300.0FalseNoneNoneFalseNoneFalse12768.00
285501392663Nonecode162Supplying & Fixing of switch mounting rack with power manager & Cable manager.12 U with 450mm depth. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 36 of 105, 8.4.4Each9895.29895.21.0FalseNoneNoneFalseNoneFalse9895.20
285501492663Nonecode163Supplying fixing of Network Switches: 24 Port 10/100 Switch. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 36 of 105, 8.9.5Each5264.05264.01.0FalseNoneNoneFalseNoneFalse5264.00
285501592663Nonecode164Supplying & fixing of I/O socket with back box.Single I/O. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 36 of 105, 8.10.1Each548.8548.824.0FalseNoneNoneFalseNoneFalse13171.20
285501692663Nonecode165DIESEL GENERATOR SET: Supplying, installing, testing and commissioning of 40 kva/32KW Diesel Generator set with following specifications. Power rating as per standard reference condition as per-BS 5514/ISO 3046/ ISO 8528 & IS 1002/ISO 3046 Generator set specifications. Engine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. Air inlet louvers specially designed to operate at rated load made on special purpose CNC machines for consistency in quality and workmanship, Powder coated for long lasting service life and superior finish, With UV resistant powder coating, can withstand extreme environment, Contd..... Use of special hardware for longer life, Insulation material meets exacting IS 8183 specifications for better sound attenuation, Flush styling - no projections, Fluid drains for lube oil and fuel, Fuel filling point inside the enclosure. The complete set shall have sufficient safety and adhere to NEC, NBC 2016, IEC, CPWD specifications, PCB norms and KSGEI Acts and Rules.40 KVA/32 KW. Make: Kirloskar/Crompton/POWERICA/ASHOK LEYLAND. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 42 of 105, 10.1.5Set626211.04626211.041.0FalseNoneNoneFalseNoneFalse626211.040
285501792663Nonecode166Supply, Erection, testing and commissioning of AMF panel suitable for 62.5 kVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .....A 4 pole contactor for alternator with thermal O/L relay,..... A 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, ....capacity bypass switch and frequency sensing, PCC 1301controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ kVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMF module by pass Mode, Battery charger unit with inbuilt Auto/Manual and Flat/Boost facility. The complete set shall have sufficient safety and adhere to NEC, NBC 2016, IEC, CPWD specifications, PCB norms and KSGEI Acts and Rules. CSR 2023-24, Volume-6, Part-III ,Utilization, SRP 42 of 105, 10.2.2Each79985.9279985.921.0FalseNoneNoneFalseNoneFalse79985.920
285501892663Nonecode167Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm alround with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. PWD ELE SR 2019-20, SRP 40/6.2No4150.04150.010.0FalseNoneNoneFalseNoneFalse41500.00
285501992663Nonecode168Supplying & running of Copper strips for grounding connections, using necessary fixing materials as required. 25 X 6mm Copper strip.PWD ELE SR 2019-20, SRP 40/6.3.7m958.0958.024.0FalseNoneNoneFalseNoneFalse22992.00
285502092663Nonecode169600 X 600 X 3mm Copper Plate. PWD ELE SR 2019-20, SRP 40/6.3.7Each6900.06900.05.0FalseNoneNoneFalseNoneFalse34500.00
285502192663Nonecode170Supplying and Installation of Mechanical Foam - 9ltrs capacity Fire Extinguishers for multipurpose ( DG, Electrical Panel). PWD ELE SR 2010-11 . SRP 65/3.Each2600.02600.02.0FalseNoneNoneFalseNoneFalse5200.00
285502292663Nonecode171Supplying of Four bucket stand along with Buckets. PWD ELE SR 2010-11. SRP 65/6.Each1200.01200.02.0FalseNoneNoneFalseNoneFalse2400.00
285502392663Nonecode172Supplying of 22kv tested Rubber Hand Gloves. PWD ELE SR 2010-11. SRP 65/8Pair170.0170.01.0FalseNoneNoneFalseNoneFalse170.00
285502492663Nonecode173Supplying & fixing of First Aid Chart with Lamination. PWD ELE SR 2010-11. SRP 65/11Each225.0225.02.0FalseNoneNoneFalseNoneFalse450.00
285502592663Nonecode174Supplying & fixing of DANGER BOARD made out of MS sheet metal with two coats of non corrossive enamel paint. PWD ELE SR 2010-11. SRP 66/12Each75.075.06.0FalseNoneNoneFalseNoneFalse450.00
285502692663Nonecode175Supplying & Installation of RUBBER MAT 1mt X 2mt-10mm thick. PWD ELE SR SRP 66/13.Each1105.01105.02.0FalseNoneNoneFalseNoneFalse2210.00
285502792663Nonecode176Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries like induction motor. Make:L&T/Indokopp CSR 2023-24,Volume-VI, SRP 19 of 105 / 5.37Kvar494.4494.41.0FalseNoneNoneFalseNoneFalse494.40
285502892663Nonecode177Fixing a shunt capacitor of 5 kVAR capacity with necessary clA, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor. Upto 5 kvar CSR 2023-24,Volume-VI, SRP57 of 105 / 13/17.1Each278.1278.11.0FalseNoneNoneFalseNoneFalse278.10
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17091870820000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17091870820000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17091870820000NoneNoneELIGIBILITYBidders Should read the terms and conditions as per tender notification.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneTo Qualify for award of this contract the Tenderer must have PF registration Certificate. Scanned copy of PF registration Certificate.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneValid EPF Certificate
NoneNoneNoneNoneTo Qualify for award of this contract the Tenderer must have valid Class - I Civil Contractors Registration Certificate, registered in KPWD / MES / CPWD as on the Date of Tender Notification. Scanned copy of Valid contractors Registration Certificate.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneTo Qualify for award of this contract the Tenderer, as a prime contractor, should have in his name satisfactorily completed at least one similar nature of work i.e. Concrete Pavement Road works with ancillary RCC Framed Structure building works costing not less than Rs.315.23 Lakhs during the last five years i.e, the work must have commenced on or after 01-04-2018 and completed till last date of submission of tenders. Work Done Certificate shall clearly mention the Date of commencement and date of completion of the certified work with stipulated time limit. Scanned copy of the Work done Completion Certificate, Certified by an Officer not below the rank of Executive Engineer for work done in Govt.,/public sector undertakings.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneTo Qualify for award of this contract the Tenderer, as a prime contractor, should have in his name Executed in any one year (For a Continuous Period of 12 Months) during last five years i.e. from 01-04-2018 till the last date of submission of Tenders. The minimum quantities of works mentioned below. 1.DLC/PCC M-5 or higher grade : 523.00 Cum 2.RCC M-20 or higher grade of concrete : 1084.00 Cum 3.Reinforcement Steel - Mild Steel/HYSD/TMT : 109000.00 Kg 4.Water Bound Macadam/Wet mix macadam : 750.00 Cum 5.Pavement concrete M30 or higher grade of concrete : 470.00Cum 6.Earth Work Excavation: 5671.00 Cum. These quantities should be executed in, either a single or multiple works in any one year (for a continuous period of 12 months) during the last 5 years. i.e.from 01-04-2018 till last date of submission of Tenders .The sum of quantities executed in all the works during the particular period (continuous period of 12 months) will be considered for evaluation. The quantities executed in works which have not been completed will also consider. Scanned copy of the Work done /Completion Certificate, along with details of quantities executed, Certified by an Officer not below the rank of Executive Engineer for work done in Govt.,/public sector undertakings should be uploaded. Out of the total quantity executed in a single work, or multiple works in any one year (for a continuous period of 12 months) during the last 5 years. Only the quantities executed in a particular year will be considered for evaluation.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneTo Qualify for award of this contract the Tenderer in his name should have, in the last five financial years ( i.e. during the years 2018-19, 2019-20, 2020-21, 2021-22 and 2022-23 ) achieved in at least two financial years a minimum financial turnover of Rs. 12,60,94,000/- (In all classes of civil engineering construction works only). Scanned copy of year wise audited profit / loss statement of two financial years in which minimum financial turnover of Rs.12,60,94,000/- is achieved. (Certified by Chartered Accountant only. Statement issued by others will not qualify for eligibility).Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneTo Qualify for award of this contract the Tenderer has to furnish Liquid assets statement or availability of credit facilities for an amount not less than Rs. 1,89,14,100/- letter of credit issued from any nationalized Bank / Schedule bank ( excluding Co-operative banks ) in the prescribed format. Scanned Copy of the Credit Lines / Letters of Credit / Certificates from any nationalized Bank / Schedule bank (excluding Co-operative banks), clearly specifying name of the work and/or work indent (as per the prescribed format) addressed to the Executive Engineer, NWKRTC, C.E. Department, HUBBALLI. (Annexure-A) duly signed by Bank manager with date.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneTo Qualify for award of this contract the assessed available tender capacity of the tenderer should be more than the amount put to tender. Note: The bid capacity of the tenderer is calculated based on the formula. Assessed Available Tender Capacity : ( (A X N x 1.5) - B) Where A : Maximum value of Civil Engineering works, updated to 2022-23 price level, executed in any one year during the last five years.( Completed as well as works in progress ). B : Value at 2022-23 price level of existing commitments and ongoing works to be completed during the next two years. N : Number of years prescribed for completion of the work for which tender is invited. 1.5 : Multiplying factor for assessing the available tender capacity for works costing more than Rs.100.00Lakhs. The Bidder/Contractor must upload the Scanned copy of details of existing commitments and ongoing works to be completed in the prescribed format only (Annexure-B) duly signed. In case the Bidder does not have any existing commitments, the same should be indicated as NIL in the prescribed format, duly signed. Details uploaded in any other format or uploaded documents in which the Bidder himself has calculated the Bid capacity will not be considered for evaluation and also will not qualify for eligibility.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Annexure B
NoneNoneNoneNoneIn case of quoted bid cost of the bidder is less than the amount put to tender, the bidder has to submit a irrevocable bank guarantee issued from any nationalized bank/schedule bank.(excluding co- operative banks) for the difference amount ( difference amount Equal to cost put to bid minus the quoted bid amount). The Original bank guarantee shall be addressed to the Executive Engineer, NWKRTC, CE Department HUBBALLI. The bidder/tenderer has to submit the Original Bank Guarantee in foolproof sealed cover within 48 hrs from the date and time of closing of tender to the Office of the Executive Engineer, NWKRTC CE Department, Central Office Hubballi. Otherwise the bid will not be considered for evaluation and will not qualify for eligibility. (Note: Tenderer Should Not Upload Bank Guarantee in the portal only).OthersBank Guarantee
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Bank Guarantee
NoneNoneNoneNoneNot ApplicableOthersNot Applicable
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Not Applicable
NoneNoneNoneNoneNot ApplicableOthersNot applicable
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Not Applicable
NoneNoneNoneNoneNot ApplicableOthersNot Applicable
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Not Applicable
NoneNoneNoneNoneNot ApplicableOthersNot Applicable
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Not Applicable
NoneNoneNoneNoneNot ApplicableOthersNot Applicable
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Not Applicable
NoneNoneNoneNoneNot ApplicableOthersNot Applicable
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Not Applicable
NoneNoneNoneNoneNot ApplicableOthersNot Applicable
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Not Applicable
tenderCriterionDocumentList
tenderWorkLocationList
tenderAddress
createdTs1709194829000
version0
createdDateNone
modifiedDateNone
blockNumberExecutive Engineer, NWKRTC, CE Department, Central Office, Old H-D City Division Office building, Opposite to M-2 Depot, Gokul Road Hubballi.
streetNone
cityHubballi
stateKarnataka
pin580030
tenderRecallDTONone