| 2853401 | 92606 | None | 001 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. SR 2023-24 Item No 1.5 V-1 | Cum | 307.97 | 307.97 | 4.32 | False | None | None | False | None | False | 1330.4304 | 0 |
| 2853402 | 92606 | None | 002 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications SR 2023-24 Item No 2.1.2 V-1 | Cum | 5833.92 | 5833.92 | 0.29 | False | None | None | False | None | False | 1691.8368 | 0 |
| 2853403 | 92606 | None | 003 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications SR 2023-24 Item No 2.2.2 V-1 | Cum | 6435.44 | 6435.44 | 1.2 | False | None | None | False | None | False | 7722.528 | 0 |
| 2853404 | 92606 | None | 004 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications SR 2021-22 Item No 2.1.4 V-1 | Cum | 6403.51 | 6403.51 | 1.08 | False | None | None | False | None | False | 6915.7908 | 0 |
| 2853405 | 92606 | None | 005 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement
including cost of all materials, machinery, labour, cleaning, straightening,
cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. SR 2023-24 Item No 2.11 b V-1 | Kg | 88.79 | 88.79 | 143.96 | False | None | None | False | None | False | 12782.2084 | 0 |
| 2853406 | 92606 | None | 006 | As per recommendation of technical Working comitee PWD SR 2023-24 rates for Formwork shall be added on 70% basis Finishing rate of Concrete For Concrete band Road medians, Traffic Separators, Dividers etc SR 2023-24 Sl No.7 V-1 Pg No 111 RCC Columns / Shaft (Slip Centering) | Sqm | 4482.46 | 4482.46 | 0.54 | False | None | None | False | None | False | 2420.5284 | 0 |
| 2853407 | 92606 | None | 007 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. SR 2023-24 Item No 8.39 V-II | Sqm | 130.81 | 130.81 | 445.11 | False | None | None | False | None | False | 58224.8391 | 0 |
| 2853408 | 92606 | None | 008 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together
with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.12.55 SR 2023-24 Item No 12.55 V-2 | Sqm | 2436.98 | 2436.98 | 15.12 | False | None | None | False | None | False | 36847.1376 | 0 |
| 2853409 | 92606 | None | 008 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.SR 2023-24 Item no 12.54 V-2 | m | 327.54 | 327.54 | 40.8 | False | None | None | False | None | False | 13363.632 | 0 |
| 2853410 | 92606 | None | 009 | KSRB13-6.1-1 : Providing and fixing in position brass bib cock of approved quality 20 mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. Specification No.KBS 13.2.2 / 13. [P-93/13.24] SR 2018-19 | No | 186.84 | 186.84 | 25.0 | False | None | None | False | None | False | 4671.0 | 0 |
| 2853411 | 92606 | None | 010 | KSRB13-6.1-1 : Providing and fixing in position brass Shower of approved quality 20 mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. Specification No.KBS 13.2.2 / 13. [P-93/13.24] SR 2018-19 | No | 489.5 | 489.5 | 20.0 | False | None | None | False | None | False | 9790.0 | 0 |
| 2853412 | 92606 | None | 011 | Providing and fixing 600x450 mm beveled edge mirror of superior glass
(of approved quality) complete with 6 mm thick hard board ground
fixed to wooden cleats with C.P. brass screws and washers complete SR 2023-24 Item no 14.31 V-2 | No | 1256.6 | 1256.6 | 8.0 | False | None | None | False | None | False | 10052.8 | 0 |
| 2853413 | 92606 | None | 012 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long,
200 mm wide with minimum distances of 37 mm from wall face with
concealed fittings arrangement of approved quality and colour, weighing
not less than 88 gms. 14.39 | No | 138.02 | 138.02 | 20.0 | False | None | None | False | None | False | 2760.4 | 0 |
| 2853414 | 92606 | None | 013 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. SR 2023-24 Item No 8.41 V-II | Sqm | 172.01 | 172.01 | 197.28 | False | None | None | False | None | False | 33934.1328 | 0 |
| 2853415 | 92606 | None | 014 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. SR 2023-24 Sl No 11.16.2 V-1I | Kg | 151.41 | 151.41 | 212.24 | False | None | None | False | None | False | 32135.2584 | 0 |
| 2853416 | 92606 | None | 015 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. PWD Ele SR 2021-22 2.3 | m | 26.0 | 26.0 | 420.0 | False | None | None | False | None | False | 10920.0 | 0 |
| 2853417 | 92606 | None | 016 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. PWD Ele SR 2021-22 2.3 | m | 40.0 | 40.0 | 180.0 | False | None | None | False | None | False | 7200.0 | 0 |
| 2853418 | 92606 | None | 016 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. PWD Ele SR 2021-22 2.3 | m | 157.0 | 157.0 | 48.0 | False | None | None | False | None | False | 7536.0 | 0 |
| 2853419 | 92606 | None | 017 | Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS
1293 and IS 3654 3.1 | No | 121.0 | 121.0 | 512.0 | False | None | None | False | None | False | 61952.0 | 0 |
| 2853420 | 92606 | None | 018 | upplying and fixing 32A security and energy saving DP switch with key tag suitable to operate on 230 V, 50Hz AC supply & completely wired on existing box. 3.7 | No | 747.0 | 747.0 | 9.0 | False | None | None | False | None | False | 6723.0 | 0 |
| 2853421 | 92606 | None | 019 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6 | No | 313.0 | 313.0 | 12.0 | False | None | None | False | None | False | 3756.0 | 0 |
| 2853422 | 92606 | None | 020 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.6.3.2 | No | 2170.0 | 2170.0 | 12.0 | False | None | None | False | None | False | 26040.0 | 0 |
| 2853423 | 92606 | None | 021 | Supplying of .feet -PVC Batten with integrated LED tube . W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE
approved. 2 years Warranty against any manufacturing defect workingunder standard electrical condition. | No | 740.0 | 740.0 | 35.0 | False | None | None | False | None | False | 25900.0 | 0 |
| 2853424 | 92606 | None | 022 | Supply of LED pole mounting type post top lantern with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/ clear glass material, delivering superior light outputRated life Burning Hrs 50000 hr@ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/1 EC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source | No | 7173.0 | 7173.0 | 4.0 | False | None | None | False | None | False | 28692.0 | 0 |