2853746 | 92617 | None | code01 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, formwork cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. COLUMNS | Cum | 11048.32 | 11048.32 | 6.14 | False | None | None | False | None | False | 67836.6848 | 0 |
2853747 | 92617 | None | code02 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, formwork cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC BEAMS | Cum | 10398.42 | 10398.42 | 9.02 | False | None | None | False | None | False | 93793.7484 | 0 |
2853748 | 92617 | None | code03 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, formwork cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. LINTELS | Cum | 10398.42 | 10398.42 | 2.8 | False | None | None | False | None | False | 29115.576 | 0 |
2853749 | 92617 | None | code04 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, formwork cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 9628.54 | 9628.54 | 2.13 | False | None | None | False | None | False | 20508.7902 | 0 |
2853750 | 92617 | None | code05 | Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy | No. | 168.1 | 168.1 | 5.0 | False | None | None | False | None | False | 840.5 | 0 |
2853751 | 92617 | None | code06 | Providing Thermo-Mechanically Treated bars of grade Fe-550 or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | Kg | 96.66 | 96.66 | 3651.054 | False | None | None | False | None | False | 352910.87964 | 0 |
2853752 | 92617 | None | code07 | KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No . KBS | Mtr | 33.0 | 33.0 | 16.5 | False | None | None | False | None | False | 544.5 | 0 |
2853753 | 92617 | None | code08 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1256.52 | 1256.52 | 230.87 | False | None | None | False | None | False | 290092.7724 | 0 |
2853754 | 92617 | None | code09 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 64720.11 | 64720.11 | 0.26 | False | None | None | False | None | False | 16827.2286 | 0 |
2853755 | 92617 | None | code10 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. | Nos | 1555.94 | 1555.94 | 2.0 | False | None | None | False | None | False | 3111.88 | 0 |
2853756 | 92617 | None | code11 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. | Nos | 874.1 | 874.1 | 2.0 | False | None | None | False | None | False | 1748.2 | 0 |
2853757 | 92617 | None | code12 | Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete. | Nos | 652.42 | 652.42 | 2.0 | False | None | None | False | None | False | 1304.84 | 0 |
2853758 | 92617 | None | code13 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete | Nos | 183.86 | 183.86 | 4.0 | False | None | None | False | None | False | 735.44 | 0 |
2853759 | 92617 | None | code14 | Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete | Nos | 116.62 | 116.62 | 4.0 | False | None | None | False | None | False | 466.48 | 0 |
2853760 | 92617 | None | code15 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms | Nos | 49.38 | 49.38 | 2.0 | False | None | None | False | None | False | 98.76 | 0 |
2853761 | 92617 | None | code16 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) | Nos | 211.17 | 211.17 | 4.0 | False | None | None | False | None | False | 844.68 | 0 |
2853762 | 92617 | None | code17 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm | Nos | 31.52 | 31.52 | 12.0 | False | None | None | False | None | False | 378.24 | 0 |
2853763 | 92617 | None | code18 | Providing & Fixing of corner beads of wooden door frame to wall including cost of materials, labour charges, complete as per specifications. | Mtr | 12.71 | 12.71 | 15.6 | False | None | None | False | None | False | 198.276 | 0 |
2853764 | 92617 | None | code19 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial | Sqm | 3092.97 | 3092.97 | 7.2 | False | None | None | False | None | False | 22269.384 | 0 |
2853765 | 92617 | None | code20 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 7606.34 | 7606.34 | 13.5 | False | None | None | False | None | False | 102685.59 | 0 |
2853766 | 92617 | None | code21 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kg | 152.34 | 152.34 | 283.5 | False | None | None | False | None | False | 43188.39 | 0 |
2853767 | 92617 | None | code22 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 181.75 | 181.75 | 83.7 | False | None | None | False | None | False | 15212.475 | 0 |
2853768 | 92617 | None | code23 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... (Inside) | Sqm | 275.26 | 275.26 | 205.43 | False | None | None | False | None | False | 56546.6618 | 0 |
2853769 | 92617 | None | code24 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 87.2 | 87.2 | 289.12 | False | None | None | False | None | False | 25211.264 | 0 |
2853770 | 92617 | None | code25 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside) | Sqm | 308.88 | 308.88 | 241.22 | False | None | None | False | None | False | 74508.0336 | 0 |
2853771 | 92617 | None | code26 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. | Mtr | 42.02 | 42.02 | 296.99 | False | None | None | False | None | False | 12479.5198 | 0 |
2853772 | 92617 | None | code27 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm | Sqm | 1157.76 | 1157.76 | 247.61 | False | None | None | False | None | False | 286672.9536 | 0 |
2853773 | 92617 | None | code28 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. | Sqm | 1983.53 | 1983.53 | 22.47 | False | None | None | False | None | False | 44569.9191 | 0 |
2853774 | 92617 | None | code29 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 99.81 | 99.81 | 289.12 | False | None | None | False | None | False | 28857.0672 | 0 |
2853775 | 92617 | None | code30 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 117.67 | 117.67 | 241.22 | False | None | None | False | None | False | 28384.3574 | 0 |
2853776 | 92617 | None | code31 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 38.87 | 38.87 | 13.5 | False | None | None | False | None | False | 524.745 | 0 |
2853777 | 92617 | None | code32 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 94.55 | 94.55 | 13.5 | False | None | None | False | None | False | 1276.425 | 0 |
2853778 | 92617 | None | code33 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 43.07 | 43.07 | 17.28 | False | None | None | False | None | False | 744.2496 | 0 |
2853779 | 92617 | None | code34 | Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 112.41 | 112.41 | 17.28 | False | None | None | False | None | False | 1942.4448 | 0 |
2853780 | 92617 | None | code35 | PVC pipes of 6 Kg/cm2 for 110mm(1.894) | Mtr | 267.9 | 267.9 | 48.0 | False | None | None | False | None | False | 12859.2 | 0 |
2853781 | 92617 | None | code36 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 152.59 | 152.59 | 9813.0 | False | None | None | False | None | False | 1497365.67 | 0 |
2853782 | 92617 | None | code37 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. | Sqm | 623.83 | 623.83 | 354.1 | False | None | None | False | None | False | 220898.203 | 0 |
2853783 | 92617 | None | code38 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Ridges plain (500 - 600mm) | m | 405.04 | 405.04 | 27.0 | False | None | None | False | None | False | 10936.08 | 0 |
2853784 | 92617 | None | code39 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Gutter (600 mm over all girth) | m | 959.31 | 959.31 | 104.8 | False | None | None | False | None | False | 100535.688 | 0 |
2853785 | 92617 | None | code40 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. | Cum | 414.02 | 414.02 | 12.58 | False | None | None | False | None | False | 5208.3716 | 0 |
2853786 | 92617 | None | code41 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. | Cum | 2084.68 | 2084.68 | 2.7 | False | None | None | False | None | False | 5628.636 | 0 |
2853787 | 92617 | None | code42 | Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km) | Cum | 132.4 | 132.4 | 16.21 | False | None | None | False | None | False | 2146.204 | 0 |
2853788 | 92617 | None | code43 | WIRES & CABLES Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch | Point | 251.0 | 251.0 | 10.0 | False | None | None | False | None | False | 2510.0 | 0 |
2853789 | 92617 | None | code44 | WIRES & CABLES Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch | Point | 361.0 | 361.0 | 20.0 | False | None | None | False | None | False | 7220.0 | 0 |
2853790 | 92617 | None | code45 | WIRES & CABLES Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch | Point | 542.0 | 542.0 | 26.0 | False | None | None | False | None | False | 14092.0 | 0 |
2853791 | 92617 | None | code46 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-3Way | Each | 123.0 | 123.0 | 5.0 | False | None | None | False | None | False | 615.0 | 0 |
2853792 | 92617 | None | code47 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way | Each | 138.0 | 138.0 | 2.0 | False | None | None | False | None | False | 276.0 | 0 |
2853793 | 92617 | None | code48 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way | Each | 212.0 | 212.0 | 2.0 | False | None | None | False | None | False | 424.0 | 0 |
2853794 | 92617 | None | code49 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall8 Way | Each | 250.0 | 250.0 | 5.0 | False | None | None | False | None | False | 1250.0 | 0 |
2853795 | 92617 | None | code50 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way | Each | 325.0 | 325.0 | 8.0 | False | None | None | False | None | False | 2600.0 | 0 |
2853796 | 92617 | None | code51 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 3 Module | Each | 152.0 | 152.0 | 5.0 | False | None | None | False | None | False | 760.0 | 0 |
2853797 | 92617 | None | code52 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module | Each | 175.0 | 175.0 | 2.0 | False | None | None | False | None | False | 350.0 | 0 |
2853798 | 92617 | None | code53 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module | Each | 244.0 | 244.0 | 2.0 | False | None | None | False | None | False | 488.0 | 0 |
2853799 | 92617 | None | code54 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module | Each | 302.0 | 302.0 | 5.0 | False | None | None | False | None | False | 1510.0 | 0 |
2853800 | 92617 | None | code55 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module | Each | 363.0 | 363.0 | 8.0 | False | None | None | False | None | False | 2904.0 | 0 |
2853801 | 92617 | None | code56 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch | Each | 88.0 | 88.0 | 66.0 | False | None | None | False | None | False | 5808.0 | 0 |
2853802 | 92617 | None | code57 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket | Each | 162.0 | 162.0 | 10.0 | False | None | None | False | None | False | 1620.0 | 0 |
2853803 | 92617 | None | code58 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. | Each | 313.0 | 313.0 | 24.0 | False | None | None | False | None | False | 7512.0 | 0 |
2853804 | 92617 | None | code59 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch | Each | 375.0 | 375.0 | 3.0 | False | None | None | False | None | False | 1125.0 | 0 |
2853805 | 92617 | None | code60 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket | Each | 249.0 | 249.0 | 3.0 | False | None | None | False | None | False | 747.0 | 0 |
2853806 | 92617 | None | code61 | Supplyin and Fixing Metal Fan Box with Round Hook. | No | 163.0 | 163.0 | 24.0 | False | None | None | False | None | False | 3912.0 | 0 |
2853807 | 92617 | None | code62 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thick | Mtr | 61.0 | 61.0 | 300.0 | False | None | None | False | None | False | 18300.0 | 0 |
2853808 | 92617 | None | code63 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thick | Mtr | 70.0 | 70.0 | 400.0 | False | None | None | False | None | False | 28000.0 | 0 |
2853809 | 92617 | None | code64 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2.5mm thick | Mtr | 93.0 | 93.0 | 100.0 | False | None | None | False | None | False | 9300.0 | 0 |
2853810 | 92617 | None | code65 | Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick | Mtr | 75.0 | 75.0 | 150.0 | False | None | None | False | None | False | 11250.0 | 0 |
2853811 | 92617 | None | code66 | Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thick | Mtr | 80.0 | 80.0 | 200.0 | False | None | None | False | None | False | 16000.0 | 0 |
2853812 | 92617 | None | code67 | Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick | Mtr | 105.0 | 105.0 | 100.0 | False | None | None | False | None | False | 10500.0 | 0 |
2853813 | 92617 | None | code68 | WIRING FOR Lighting/Power Circuits Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm | Mtr | 26.0 | 26.0 | 200.0 | False | None | None | False | None | False | 5200.0 | 0 |
2853814 | 92617 | None | code69 | WIRING FOR Lighting/Power Circuits Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm | Mtr | 40.0 | 40.0 | 500.0 | False | None | None | False | None | False | 20000.0 | 0 |
2853815 | 92617 | None | code70 | WIRING FOR Lighting/Power Circuits Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmm | Mtr | 59.0 | 59.0 | 100.0 | False | None | None | False | None | False | 5900.0 | 0 |
2853816 | 92617 | None | code71 | WIRING FOR Lighting/Power Circuits Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmm | Mtr | 87.0 | 87.0 | 150.0 | False | None | None | False | None | False | 13050.0 | 0 |
2853817 | 92617 | None | code72 | MCB DB Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door. 6 Way TP & N | Each | 3735.0 | 3735.0 | 1.0 | False | None | None | False | None | False | 3735.0 | 0 |
2853818 | 92617 | None | code73 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN | Each | 2399.0 | 2399.0 | 1.0 | False | None | None | False | None | False | 2399.0 | 0 |
2853819 | 92617 | None | code74 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board 32-40 Amps 4 pole | Each | 2826.0 | 2826.0 | 1.0 | False | None | None | False | None | False | 2826.0 | 0 |
2853820 | 92617 | None | code75 | ELECTRICAL FIXTURES Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w | Each | 740.0 | 740.0 | 32.0 | False | None | None | False | None | False | 23680.0 | 0 |
2853821 | 92617 | None | code76 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular model | Each | 2085.0 | 2085.0 | 24.0 | False | None | None | False | None | False | 50040.0 | 0 |
2853822 | 92617 | None | code77 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders | Each | 119.0 | 119.0 | 32.0 | False | None | None | False | None | False | 3808.0 | 0 |
2853823 | 92617 | None | code78 | Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. | Each | 281.0 | 281.0 | 24.0 | False | None | None | False | None | False | 6744.0 | 0 |