| tenderSubEstimateList | | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
|---|
| 1709347272000 | 0 | None | None | Buildings | Supplying of Toilet Cleaning Machine and Repairs of School Building in KPS School at JP Nagar Karatagi | 247856.5 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 2878948 | 94098 | None | Basic Rate | RO Water Plant for Hemodialysis 500 Ltrs/Hr Capacity Specifications Plant capacity (Ltrs/Hr) 500 Plant type Microprocessor/microcontroller controlled single stage RO water system ( Feed water TDS more than 500 PPM) System type Online ,Offline Double raw water pump ( one active and the other stand by) No Raw water feed pump capacity (LPH) 1500 Micron particle filter after activated Carbon filter for removing suspended particles more than micron size 5 Distribution of RO plant water sufficient for number of dialysis machines 5-10 Material of Booster pump (offline) Stainless Steel 316 | Nos | 159000.0 | 159000.0 | 1.0 | False | None | None | False | None | False | 159000.0 | 0 | | 2878949 | 94098 | None | Basic Rate | Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. For 3 HP etc. complete. 3.00 HP - 300 LPM @ 26 m = 5 STG Outlet Dia - 2.50" | Each | 24326.4 | 24326.4 | 1.0 | False | None | None | False | None | False | 24326.4 | 0 | | 2878950 | 94098 | None | 1.6.1 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required
to complete the work. | Nos | 508.2 | 508.2 | 34.0 | False | None | None | False | None | False | 17278.8 | 0 | | 2878951 | 94098 | None | Basic Rate | Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for
testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0 | Each | 198.45 | 198.45 | 34.0 | False | None | None | False | None | False | 6747.3 | 0 | | 2878952 | 94098 | None | Basic Rate | Stainless Steel Top Loading Sanitary Napkin Incinerator Machine Burning Ability 500 Kg time | No | 24000.0 | 24000.0 | 1.0 | False | None | None | False | None | False | 24000.0 | 0 | | 2878953 | 94098 | None | I. No. 1.1.1 | SupplyingandwiringadoptingloopsysteminexistingPVCConduit/casingcappingusing2x1.5Sqmm(Phase&Neutral)&1x1.0sqmm(Earthwire)FRLSmultistrandPVCinsulatedcopperwire(confirmingtoIS-694:andlatestamendments)with a6AmpsflushtypeSPcontrolswitchshallbefixedontheexistingplasticsheet/gangbox,theotherendofthewiresshallbeterminatedwithsufficientlooselengthinawood/PVCroundblock.completeforeach outlet. | No | 285.0 | 285.0 | 1.0 | False | None | None | False | None | False | 285.0 | 0 | | 2878954 | 94098 | None | I. No.2.2.2 ,) | Mediumpointabove3Mtrupto6Mtrfromtappingpointtooutletviaswitch | No | 394.0 | 394.0 | 1.0 | False | None | None | False | None | False | 394.0 | 0 | | 2878955 | 94098 | None | 2.2.3 | c) Long Point using Class A. Material | No | 555.0 | 555.0 | 1.0 | False | None | None | False | None | False | 555.0 | 0 | | 2878956 | 94098 | None | 3.1.2 | Supplying6Aflushtypesocketand6AflushtypeSPswitcheithersurface/flushmountinginexistinggangboxorin4mmthickplasticsheetandfixingoveraflushmountedwoodenboxandwiringusingnecessary capacity wires as required as per IS 1293 and IS 3854 b)6Amps 3/5 way | Nos | 147.0 | 147.0 | 4.0 | False | None | None | False | None | False | 588.0 | 0 | | 2878957 | 94098 | None | 12.60.1 | Supplying&FixingChemicalearthlingforgrounding.Conduits,ICcut-outs&otherequipmentsbackfillcompoundwhichisnon-corrosive,thermallyconductive,potentialtopermissiblelimits,superiorFaultconductioncapacity,nontoxic,weatherresistance&capable of achieving ohmic value less than one ohmUsing 4ft. Copper bonded rod with backfill compound | Nos | 4528.0 | 4528.0 | 1.0 | False | None | None | False | None | False | 4528.0 | 0 | | 2878958 | 94098 | None | 9.3 | Supplying capacitor type ceiling fan complete with down rod blades shakle canopies for operation on 230V 50 cycles phase AC supply confirming to ISS 374-1979 and with double ball bearing system (84/9.3) | Nos | 1900.0 | 1900.0 | 3.0 | False | None | None | False | None | False | 5700.0 | 0 | | 2878959 | 94098 | None | 11.14.2 | Supplyingandfixingofslimboxfitting,madeoutofCRCASheetmetalbodywithlockingtypeholdercompletelywired.ExcludingBallast & Fluorescent Tube. 1 x 4' Tube light fitting. | Nos | 361.0 | 361.0 | 6.0 | False | None | None | False | None | False | 2166.0 | 0 | | 2878960 | 94098 | None | 13.1.1 | SupplyingandFixingof.mmdiaclassAGIpipebracketupto2mslongbentatsuitableangleandfixingtothisbracketstreetlightfittingofallcapacitiestoGIorGIorrailorRCpole/wallusingsuitableclamps,bolts,andnutsandwiringusingsuitablecapacitywires. Using 25mm dia G.I.Pipe | No | 978.0 | 978.0 | 1.0 | False | None | None | False | None | False | 978.0 | 0 | | 2878961 | 94098 | None | P No 6 | Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010 1.5 Sqmm | Mtr | 26.0 | 26.0 | 10.0 | False | None | None | False | None | False | 260.0 | 0 | | 2878962 | 94098 | None | P No 6 | Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010 2.5 sqm | Mtr | 42.0 | 42.0 | 10.0 | False | None | None | False | None | False | 420.0 | 0 | | 2878963 | 94098 | None | P No 6 | Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010 4 Sqm | Mtr | 63.0 | 63.0 | 10.0 | False | None | None | False | None | False | 630.0 | 0 |
| | 1709347272000 | 0 | None | None | Buildings | Construction of Rooms , Const of Water Tank Supplying and Fixing of RO Plant Electrfication Toilet Cleaning Machine to GHPS School at Chikamadinal Village | 1815402.37 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 2878964 | 94099 | None | 1.4 | Earth work excavation by manual means for drains, canals, waste weir, draft,
approach channels, key trenches, foundation of Buildings & bridges and such
simillar works in all kinds of soils, as per drawing and technical specifications,
including setting out, shoring, strutting, barricading, caution lights, removal
of stumps and other deleterious matter, excavated surface leveled and sides
neatly dressed disposing off the excavated stuff or sorting & stacking the
selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of
labour, tools & other appurtenaces required to complete the work. | Cum | 254.1 | 254.1 | 41.513 | False | None | None | False | None | False | 10548.4533 | 0 | | 2878965 | 94099 | None | 2.1.1 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in
layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates work as per technical specifications | Cum | 5947.2 | 5947.2 | 12.72 | False | None | None | False | None | False | 75648.384 | 0 | | 2878966 | 94099 | None | 5.2 | Providing Coursed rubble masonry (first sort) with hard stone in foundation
and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6948.9 | 6948.9 | 11.31 | False | None | None | False | None | False | 78592.059 | 0 | | 2878967 | 94099 | None | 5.3 | Providing Coursed rubble masonry (second sort) with hard stone in
foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand | Cum | 6515.25 | 6515.25 | 8.11 | False | None | None | False | None | False | 52838.6775 | 0 | | 2878968 | 94099 | None | 5.4 | Providing Size Stone masonry with hard stone in foundation & plinth with
Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6708.45 | 6708.45 | 12.3 | False | None | None | False | None | False | 82513.935 | 0 | | 2878969 | 94099 | None | 1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of
foundations and other similar works etc. in layers not exceeding 20cm in depth,
consolidating each deposited layer by ramming and watering, lead up to 50 m
and lift upto 1.5 m. | Cum | 279.3 | 279.3 | 45.9 | False | None | None | False | None | False | 12819.87 | 0 | | 2878970 | 94099 | None | 2.2.1 | Providing and laying in position Cement Concrete for all Foundation works.
The granite/trap/basalt crushed graded coarse aggregates and fine aggregates
as per relevant IS Codes machine mixed with super plasticizers laid in finished
layers, well compacted using needle vibrators, including all lead & lifts, cost
of all materials, quality confirming to the requirements of relevant IS codes,
labour, Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6601.35 | 6601.35 | 26.33 | False | None | None | False | None | False | 173813.5455 | 0 | | 2878971 | 94099 | None | 2.5.1 | Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cum | Sqm | 330.07 | 330.07 | 1.73 | False | None | None | False | None | False | 571.0211 | 0 | | 2878972 | 94099 | None | 2.5.1 | Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cum | Sqm | 660.14 | 660.14 | 2.73 | False | None | None | False | None | False | 1802.1822 | 0 | | 2878973 | 94099 | None | 2.5.1 | Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cum | Sqm | 3960.81 | 3960.81 | 5.76 | False | None | None | False | None | False | 22814.2656 | 0 | | 2878974 | 94099 | None | 2.5.1 | Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cum | Sqm | 3300.68 | 3300.68 | 13.1 | False | None | None | False | None | False | 43238.908 | 0 | | 2878975 | 94099 | None | 2.11 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement
including cost of all materials, machinery, labour, cleaning, straightening,
cutting, bending, hooking, laping/welding joints, tying with binding wire / soft
annealed steel wire and other ancilary operations complete as per drawing and
technical specification.
| Tonne | 93929.85 | 93929.85 | 2.75 | False | None | None | False | None | False | 258307.0875 | 0 | | 2878976 | 94099 | None | 6.7 | Providing Brick work with common burnt clay Non Modular bricks of
class designation 3.5 in superstructure above plinth level in all shapes and
sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of
all materials, labour, scaffolding and usage charges of machinery & other
incidental charges complete as per the direction of engineer incharge of
work. | Cum | 8621.55 | 8621.55 | 19.64 | False | None | None | False | None | False | 169327.242 | 0 | | 2878977 | 94099 | None | 11.34B | Providing and fixing M.S. grills of required pattern in frames of windows
etc. with M.S. flats, square or round bars etc. including priming coat with
approved steel primer all complete. Fixed to openings /wooden frames
with rawl plugs screws etc. | Sqm | 192.15 | 192.15 | 177.66 | False | None | None | False | None | False | 34137.369 | 0 | | 2878978 | 94099 | None | 8.6.1 | Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3
coarse sand) finished with a floating coat of neat cement to brick masonry
including rounding off corners wherever required smooth rendering,
providing and removing scaffolding, including cost of materials, labour,
curing complete as per specifications and as per directions of Engineerin-charge. | Sqm | 339.15 | 339.15 | 84.78 | False | None | None | False | None | False | 28753.137 | 0 | | 2878979 | 94099 | None | 8.7 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement:
3 coarse sand) finished with a floating coat of neat cement on the rough
side of single or half brick wall including rounding off corners wherever
required smooth rendering, providing and removing scaffolding, including
cost of materials, labour, curing complete as per specifications and as per
directions of Engineer-in-charge | Sqm | 279.3 | 279.3 | 115.38 | False | None | None | False | None | False | 32225.634 | 0 | | 2878980 | 94099 | None | 8.33.1 | Finishing with Deluxe Multi surface paint system for interiors and exteriors
using Primer as per manufacturers specifications: Two coats applied on
walls @ 1.25 L/10 m² over and including one coat of Special primer applied
@ 0.75 L/10 m² with paint of approved quality to give an even shade, after
thoroughly brooming the surface to remove all dirt, dust, mortar drops
and foreign matter including preparing the surface even and sand paper
smooth, cost of materials, labour complete as per specifications and as per
directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree
angle with 10 years life) | Sqm | 165.9 | 165.9 | 84.78 | False | None | None | False | None | False | 14065.002 | 0 | | 2878981 | 94099 | None | 8.29 | Finishing walls with textured exterior paint of required shade :New work
(Two coats applied @ 3.28 L/10 m²) over and including priming coat of
exterior primer applied @ 2.20kg/10 m² to give an even shade after
thoroughly brooming the surface to remove all dirt, dust, mortar drops
and foreign matter including preparing the surface even and sand paper
smooth, cost of materials, labour complete as per specifications and as per
directions of Engineer-in-charge. | Sqm | 297.15 | 297.15 | 115.38 | False | None | None | False | None | False | 34285.167 | 0 | | 2878982 | 94099 | None | 9.12.2 | Providing and laying vitrified floor tiles with thickness 9-10 mm in
different sizes with water absorption less than 0.08% and conforming to
IS: 15622, of approved make, in all colours and shades, laid on 20mm thick
cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement
slurry @ 3.3 kg/ m2 including grouting the joints with white cement and
matching pigments etc., complete.Size of Tile 600x600 mm | Sqm | 1202.25 | 1202.25 | 57.8 | False | None | None | False | None | False | 69490.05 | 0 | | 2878983 | 94099 | None | 9.34 | Flooring with 25mm thick polished tandur blue stone slabs using cement
mortar 1:6, 25mm thick over existing cement concrete bed or top of roof
laid to line and level and jointed with cement slurry mixed with pigment
to match the shade of the slab, , including cost of materials, labour,
curing, polishing complete as per specifications | Sqm | 1622.25 | 1622.25 | 18.7 | False | None | None | False | None | False | 30336.075 | 0 | | 2878984 | 94099 | None | 12.12 | Providing Mathi/Nandi wood frames of doors, windows, clerestory
windows, ventilators and other frames, wrought, framed or assembled
including making plaster groves (excluding cost of cement concrete and side
clamps ), but including cost of materials, labour, usage charges complete
as per specifications.
| Cum | 130412.1 | 130412.1 | 0.24 | False | None | None | False | None | False | 31298.904 | 0 | | 2878985 | 94099 | None | 12.15 | Providing and fixing in position fully panelled Honne wood shutters for
doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm
wide top rail and stiles 100mm wide as per drawing and panels of 25mm
thick including cost of materials, labour, usage charges complete as per
specifications. ( excluding cost of fixtures ) | Sqm | 7816.2 | 7816.2 | 8.28 | False | None | None | False | None | False | 64718.136 | 0 | | 2878986 | 94099 | None | 12.55.1 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled
Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and
15x15mm for top & bottom rails, covered with heat moulded Prelaminated
PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm
thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom
rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert
for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated
on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC
Designer beading on either side & joined together with solvent cement
adhesive etc., Complete as per manufacturers specification & direction of
Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges | Sqm | 2484.3 | 2484.3 | 1.58 | False | None | None | False | None | False | 3925.194 | 0 | | 2878987 | 94099 | None | 8.49 | Lettering with black Japan paint of approved brand and manufacture to give
an even shade including preparing the surface after thoroughly cleaning the
surface to remove all dirt, dust and foreign matter, cost of materials, labour
complete as per specifications and as per directions of Engineer-in-charge | No | 4.2 | 4.2 | 7000.0 | False | None | None | False | None | False | 29400.0 | 0 | | 2878988 | 94099 | None | 88.84 | Providing Wall black in 12 mm thick with CM 1:3 and applied with primer and two coats of acyrlic emulsion black paint including finishing etc complete | Sqm | 498.75 | 498.75 | 3.6 | False | None | None | False | None | False | 1795.5 | 0 | | 2878989 | 94099 | None | 12.80 | Providing and Fixing door latch with necessary screws etc complete | Sqm | 299.25 | 299.25 | 3.6 | False | None | None | False | None | False | 1077.3 | 0 | | 2878990 | 94099 | None | 20.27.3 | Providing and Fixing bright finished brass flush bolts with necessary brass screws etc cpmplete | Each | 172.2 | 172.2 | 22.0 | False | None | None | False | None | False | 3788.4 | 0 | | 2878991 | 94099 | None | 1.1.1 | Electrification:Supplying heavy gauge PVC conduit pipe . dia . mm thick
confirming to IS 2509 with suitable size bends, junction boxes,
adhesive paste etc , and fixing using inverted wood plugs in case of
RCC ceiling and RCC wall/ stone structure or rawl plugs in case of
brick walls and cement plastering the damaged portion using heavy
gauge saddles at an interval of 700mm using NF screws.19/20 mm dia 2 mm thick | Mtr | 69.0 | 69.0 | 40.0 | False | None | None | False | None | False | 2760.0 | 0 | | 2878992 | 94099 | None | 1.4.1 | Supplying and fixing sheet Metal box made out of 18 SWG sheet
metal with necessary holes for cable/conduit entry as required with one
coat of primer of approved make etc 75 x 75 x 65 mm | Nos | 106.0 | 106.0 | 4.0 | False | None | None | False | None | False | 424.0 | 0 | | 2878993 | 94099 | None | 2.2.1 | Supplying and wiring adopting loop system in existing PVC Conduit
/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral)
& 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated
copper wire (confirming to IS-694: and latest amendments) without
control switch shall be fixed on the existing plastic sheet/ gang box,
the other end of the wires shall be terminated with sufficient loose
length in a wood/PVC round block. complete for each outlet.Short point upto 3Mtr from tapping point to out let via switch box | Nos | 285.0 | 285.0 | 4.0 | False | None | None | False | None | False | 1140.0 | 0 | | 2878994 | 94099 | None | 2.2.3 | Medium point above 3Mtr upto 6Mtr from tapping point to out let via
switch box | Nos | 394.0 | 394.0 | 4.0 | False | None | None | False | None | False | 1576.0 | 0 | | 2878995 | 94099 | None | 2.2.3 | Long point above 6Mtr upto 10Mtr from tapping point to out let via
switch box | Nos | 555.0 | 555.0 | 4.0 | False | None | None | False | None | False | 2220.0 | 0 | | 2878996 | 94099 | None | 3.8 | Supplying 4mm thick plastic sheet with necessary nitches for
fixing switches, regulators etc, and fixing on existing wooden or
metal box using N.F. screws. | Sqm | 0.41 | 0.41 | 1500.0 | False | None | None | False | None | False | 615.0 | 0 | | 2878997 | 94099 | None | 3.1.2 | Supplying 6A flush type socket and 6 A flush type SP switch either
surface/flush mounting in existing gang box or in 4mm thick plastic
sheet and fixing over a flush mounted wooden box and wiring using
necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 Way | Nos | 147.0 | 147.0 | 12.0 | False | None | None | False | None | False | 1764.0 | 0 | | 2878998 | 94099 | None | 12.60 | Supplying & Fixing Chemical earthling for grounding. Conduits, IC
cut-outs & other equipments backfill compound which is noncorrosive, thermally conductive, potential to permissible limits,
superior Fault conduction capacity, non toxic, weather resistance &
capable of achieving ohmic value less than one ohm Using 4ft. Copper bonded rod with backfill compound | Nos | 4528.0 | 4528.0 | 1.0 | False | None | None | False | None | False | 4528.0 | 0 | | 2878999 | 94099 | None | 6.3 | Supplying capacitor type ceiling fan complete with down rod blades,
shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase
AC supply conforming to ISS-374- 1979 and with double ball bearing
system | Nos | 1900.0 | 1900.0 | 6.0 | False | None | None | False | None | False | 11400.0 | 0 | | 2879000 | 94099 | None | 11.14.2 | Supplying and fixing of slim box fitting, made out of CRCA Sheet
metal body with locking type holder completely wired. Excluding
Ballast & Fluorescent Tube 1 x 4' Tube light fitting | Nos | 361.0 | 361.0 | 6.0 | False | None | None | False | None | False | 2166.0 | 0 | | 2879001 | 94099 | None | 13.1.1 | Supplying and Fixing of.mm dia class A GI pipe bracket upto 2
ms long bent at suitable angle and fixing to this bracket street light
fitting of all capacities to GI or GI or rail or RCC pole / wall using
suitable clamps, bolts, and nuts and wiring using suitable capacity
wires Using 25mm dia G.I.Pipe | Nos | 978.0 | 978.0 | 1.0 | False | None | None | False | None | False | 978.0 | 0 | | 2879002 | 94099 | None | P No 23 | Pre - Paid Energy Meter Single Phase, 5-30 Amps, 1.0
Accuracy Class with Key Pad Technology consumer
interface unit along with pillfer proof box | No | 7170.0 | 7170.0 | 1.0 | False | None | None | False | None | False | 7170.0 | 0 | | 2879003 | 94099 | None | P No 6 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010
1.5 mm | Mtr | 26.0 | 26.0 | 40.0 | False | None | None | False | None | False | 1040.0 | 0 | | 2879004 | 94099 | None | P No 6 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 2.5 mm | Mtr | 42.0 | 42.0 | 40.0 | False | None | None | False | None | False | 1680.0 | 0 | | 2879005 | 94099 | None | P No 6 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:20104 mm2 | Mtr | 63.0 | 63.0 | 40.0 | False | None | None | False | None | False | 2520.0 | 0 | | 2879006 | 94099 | None | I No.8.33.1 (Volume 2) | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign atter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 165.9 | 165.9 | 72.0 | False | None | None | False | None | False | 11944.8 | 0 | | 2879007 | 94099 | None | 19.22 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction
of Engineer-in-charge | Cum | 50.4 | 50.4 | 81.2 | False | None | None | False | None | False | 4092.48 | 0 | | 2879008 | 94099 | None | 2.1.1 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required t complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M7.5) Using 40 mm nominal size graded crushed coarse aggregates
| Cum | 5947.2 | 5947.2 | 8.12 | False | None | None | False | None | False | 48291.264 | 0 | | 2879009 | 94099 | None | 9.12.2 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grou ting the joints with white cement and matching pigments etc., complete. (Size of Tile 600x600 mm) | Sqm | 1202.25 | 1202.25 | 86.32 | False | None | None | False | None | False | 103778.22 | 0 | | 2879010 | 94099 | None | 1.1.1 | SupplyingheavygaugePVCconduitpipe.dia.mmthickconfirmingtoIS2509withsuitablesizebends,junctionboxes,adhesivepasteetc,andfixingusinginvertedwoodplugsincaseofRCCceilingandRCCwall/stonestructureorrawlplugsincaseofbrickwallsandcementplasteringthedamagedportionusingheavygauge saddles at an interval of 700mm using NF screws. | Mtr | 69.0 | 69.0 | 20.0 | False | None | None | False | None | False | 1380.0 | 0 | | 2879011 | 94099 | None | Basic Rate | SupplyingandfixingsheetMetalboxmadeoutof18SWGsheetmetalwithnecessaryholesforcable/conduitentryasrequiredwithonecoat of primer of approved make etc. | Nos | 106.0 | 106.0 | 4.0 | False | None | None | False | None | False | 424.0 | 0 | | 2879012 | 94099 | None | 2.2.1 | SupplyingandwiringadoptingloopsysteminexistingPVCConduit/casingcappingusing2x1.5Sqmm(Phase&Neutral)&1x1.0sqmm(Earthwire)FRLSmultistrandPVCinsulatedcopperwire(confirmingtoIS-694:andlatestamendments)with a6AmpsflushtypeSPcontrolswitchshallbefixedontheexistingplasticsheet/gangbox,theotherendofthewiresshallbeterminatedwithsufficientlooselengthinawood/PVCroundblock.completeforeach outlet. a) Short Point using Class A. Material | No | 285.0 | 285.0 | 2.0 | False | None | None | False | None | False | 570.0 | 0 | | 2879013 | 94099 | None | 2.2.3 | SupplyingandwiringadoptingloopsysteminexistingPVCConduit/casingcappingusing2x1.5Sqmm(Phase&Neutral)&1x1.0sqmm(Earthwire)FRLSmultistrandPVCinsulatedcopperwire(confirmingtoIS-694:andlatestamendments)with a6AmpsflushtypeSPcontrolswitchshallbefixedontheexistingplasticsheet/gangbox,theotherendofthewiresshallbeterminatedwithsufficientlooselengthinawood/PVCroundblock.completeforeach outlet. Mediumpointabove3Mtrupto6Mtrfromtappingpointtooutletviaswitchno | No | 394.0 | 394.0 | 2.0 | False | None | None | False | None | False | 788.0 | 0 | | 2879014 | 94099 | None | 2.2.3 | SupplyingandwiringadoptingloopsysteminexistingPVCConduit/casingcappingusing2x1.5Sqmm(Phase&Neutral)&1x1.0sqmm(Earthwire)FRLSmultistrandPVCinsulatedcopperwire(confirmingtoIS-694:andlatestamendments)with a6AmpsflushtypeSPcontrolswitchshallbefixedontheexistingplasticsheet/gangbox,theotherendofthewiresshallbeterminatedwithsufficientlooselengthinawood/PVCroundblock.completeforeach outlet.c) Long Point using Class A. Material | No | 555.0 | 555.0 | 2.0 | False | None | None | False | None | False | 1110.0 | 0 | | 2879015 | 94099 | None | 3.8 | Supplying4mmthickplasticsheetwithnecessarynitchesforfixingswitches,regulatorsetc,andfixingonexistingwoodenormetal box using N.F. screws. | Sqm | 0.41 | 0.41 | 1000.0 | False | None | None | False | None | False | 410.0 | 0 | | 2879016 | 94099 | None | 3.1.2 | Supplying6Aflushtypesocketand6AflushtypeSPswitcheithersurface/flushmountinginexistinggangboxorin4mmthickplasticsheetandfixingoveraflushmountedwoodenboxandwiringusingnecessary capacity wires as required as per IS 1293 and IS 3854 | No | 147.0 | 147.0 | 5.0 | False | None | None | False | None | False | 735.0 | 0 | | 2879017 | 94099 | None | 9.13 | Supplying capacitor type ceiling fan complete with down rod blades shakle canopies for operation on 230V 50 cycles phase AC supply confirming to ISS 374-1979 and with double ball bearing system (84/9.3) | No | 1900.0 | 1900.0 | 1.0 | False | None | None | False | None | False | 1900.0 | 0 | | 2879018 | 94099 | None | 11.14.2 | Supplyingandfixingofslimboxfitting,madeoutofCRCASheetmetalbodywithlockingtypeholdercompletelywired.ExcludingBallast & Fluorescent Tube. 1 x 4' Tube light fitting. | No | 361.0 | 361.0 | 2.0 | False | None | None | False | None | False | 722.0 | 0 | | 2879019 | 94099 | None | I. No.2.3.2,3.2.2.3,3.235.4) | Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010 1.5 sqm | Mtr | 26.0 | 26.0 | 15.0 | False | None | None | False | None | False | 390.0 | 0 | | 2879020 | 94099 | None | I. No.2.3.2,3.2.2.3,3.235.4) | Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010 2.5 sqm | Mtr | 42.0 | 42.0 | 15.0 | False | None | None | False | None | False | 630.0 | 0 | | 2879021 | 94099 | None | I. No.2.3.2,3.2.2.3,3.235.4) | Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010 4 sqm | Mtr | 63.0 | 63.0 | 15.0 | False | None | None | False | None | False | 945.0 | 0 | | 2879022 | 94099 | None | Basic Rate | cleaning machin Stainless Steel Top Loading Sanitary Napkin Incinerator Machine, Burning Ability: 500 Kg/time | No | 24000.0 | 24000.0 | 1.0 | False | None | None | False | None | False | 24000.0 | 0 | | 2879023 | 94099 | None | Basic Rate | RO Water Plant for Hemodialysis 500 Ltrs/Hr Capacity Specifications Plant capacity (Ltrs/Hr) 500 Plant type Microprocessor/microcontroller controlled single stage RO water system ( Feed water TDS more than 500 PPM) System type Online ,Offline Double raw water pump ( one active and the other stand by) No Raw water feed pump capacity (LPH) 1500 Micron particle filter after activated Carbon filter for removing suspended particles more than micron size 5 Distribution of RO plant water sufficient for number of dialysis machines 5-10 Material of Booster pump (offline) Stainless Steel 316 | No | 159000.0 | 159000.0 | 1.0 | False | None | None | False | None | False | 159000.0 | 0 | | 2879024 | 94099 | None | 13.11.1 | Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. For 3 HP etc. complete. 3.00 HP - 300 LPM @ 26 m = 5 STG Outlet Dia - 2.50" | Each | 23326.4 | 23326.4 | 1.0 | False | None | None | False | None | False | 23326.4 | 0 | | 2879025 | 94099 | None | I No.1.6.1 (Volume 1) | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required
to complete the work. | No | 508.2 | 508.2 | 38.0 | False | None | None | False | None | False | 19311.6 | 0 | | 2879026 | 94099 | None | I No.9.1.1 (Volume 5) | Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for
testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0 | No | 198.45 | 198.45 | 38.0 | False | None | None | False | None | False | 7541.1 | 0 |
| | 1709347272000 | 0 | None | None | Buildings | Supplying of Toilet Cleaning Machine Repairs of Electrification Water Supply and Installation of RO Plant at Navali School | 255945.45 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 2879027 | 94100 | None | Basic Rate | RO Water Plant for Hemodialysis 500 Ltrs/Hr Capacity Specifications Plant capacity (Ltrs/Hr) 500 Plant type Microprocessor/microcontroller controlled single stage RO water system ( Feed water TDS more than 500 PPM) System type Online ,Offline Double raw water pump ( one active and the other stand by) No Raw water feed pump capacity (LPH) 1500 Micron particle filter after activated Carbon filter for removing suspended particles more than micron size 5 Distribution of RO plant water sufficient for number of dialysis machines 5-10 Material of Booster pump (offline) Stainless Steel 316 | No | 160000.0 | 160000.0 | 1.0 | False | None | None | False | None | False | 160000.0 | 0 | | 2879028 | 94100 | None | 1.6.1 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required
to complete the work.In all kinds of soils. Depth upto 1.50m | No | 508.2 | 508.2 | 36.0 | False | None | None | False | None | False | 18295.2 | 0 | | 2879029 | 94100 | None | 13.11.1 | Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. For 3 HP etc. complete. 3.00 HP - 300 LPM @ 26 m = 5 STG Outlet Dia - 2.50" | Each | 24326.4 | 24326.4 | 1.0 | False | None | None | False | None | False | 24326.4 | 0 | | 2879030 | 94100 | None | 9.1.1 | Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for
testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0 HDPE Grade PE80-PN6.0, 63mm dia | Mtr | 198.45 | 198.45 | 33.0 | False | None | None | False | None | False | 6548.85 | 0 | | 2879031 | 94100 | None | 1.1.1 | SupplyingheavygaugePVCconduitpipe.dia.mmthickconfirmingtoIS2509withsuitablesizebends,junctionboxes,adhesivepasteetc,andfixingusinginvertedwoodplugsincaseofRCCceilingandRCCwall/stonestructureorrawlplugsincaseofbrickwallsandcementplasteringthedamagedportionusingheavygauge saddles at an interval of 700mm using NF screws. | Mtr | 69.0 | 69.0 | 20.0 | False | None | None | False | None | False | 1380.0 | 0 | | 2879032 | 94100 | None | 1.4.1 | SupplyingandfixingsheetMetalboxmadeoutof18SWGsheetmetalwithnecessaryholesforcable/conduitentryasrequiredwithonecoat of primer of approved make etc. | No | 106.0 | 106.0 | 4.0 | False | None | None | False | None | False | 424.0 | 0 | | 2879033 | 94100 | None | 2.2.1 | SupplyingandwiringadoptingloopsysteminexistingPVCConduit/casingcappingusing2x1.5Sqmm(Phase&Neutral)&1x1.0sqmm(Earthwire)FRLSmultistrandPVCinsulatedcopperwire(confirmingtoIS-694:andlatestamendments)with a6AmpsflushtypeSPcontrolswitchshallbefixedontheexistingplasticsheet/gangbox,theotherendofthewiresshallbeterminatedwithsufficientlooselengthinawood/PVCroundblock.completeforeach outlet.a) Short Point using Class A. Material | No | 285.0 | 285.0 | 5.0 | False | None | None | False | None | False | 1425.0 | 0 | | 2879034 | 94100 | None | 2.2.2 | SupplyingandwiringadoptingloopsysteminexistingPVCConduit/casingcappingusing2x1.5Sqmm(Phase&Neutral)&1x1.0sqmm(Earthwire)FRLSmultistrandPVCinsulatedcopperwire(confirmingtoIS-694:andlatestamendments)with a6AmpsflushtypeSPcontrolswitchshallbefixedontheexistingplasticsheet/gangbox,theotherendofthewiresshallbeterminatedwithsufficientlooselengthinawood/PVCroundblock.completeforeach outlet.Mediumpointabove3Mtrupto6Mtrfromtappingpointtooutletviaswitch | Nos | 394.0 | 394.0 | 5.0 | False | None | None | False | None | False | 1970.0 | 0 | | 2879035 | 94100 | None | 2.2.3 | SupplyingandwiringadoptingloopsysteminexistingPVCConduit/casingcappingusing2x1.5Sqmm(Phase&Neutral)&1x1.0sqmm(Earthwire)FRLSmultistrandPVCinsulatedcopperwire(confirmingtoIS-694:andlatestamendments)with a6AmpsflushtypeSPcontrolswitchshallbefixedontheexistingplasticsheet/gangbox,theotherendofthewiresshallbeterminatedwithsufficientlooselengthinawood/PVCroundblock.completeforeach outlet.c) Long Point using Class A. Material | Point | 555.0 | 555.0 | 5.0 | False | None | None | False | None | False | 2775.0 | 0 | | 2879036 | 94100 | None | 3.8 | Supplying4mmthickplasticsheetwithnecessarynitchesforfixingswitches,regulatorsetc,andfixingonexistingwoodenormetal box using N.F. screws. | Sqm | 0.41 | 0.41 | 800.0 | False | None | None | False | None | False | 328.0 | 0 | | 2879037 | 94100 | None | 3.1.2 | Supplying6Aflushtypesocketand6AflushtypeSPswitcheithersurface/flushmountinginexistinggangboxorin4mmthickplasticsheetandfixingoveraflushmountedwoodenboxandwiringusingnecessary capacity wires as required as per IS 1293 and IS 3854 | No | 147.0 | 147.0 | 8.0 | False | None | None | False | None | False | 1176.0 | 0 | | 2879038 | 94100 | None | 9.3 | Supplying capacitor type ceiling fan complete with down rod blades shakle canopies for operation on 230V 50 cycles phase AC supply confirming to ISS 374-1979 and with double ball bearing system (84/9.3) | No | 1900.0 | 1900.0 | 4.0 | False | None | None | False | None | False | 7600.0 | 0 | | 2879039 | 94100 | None | 11.14.2 | Supplyingandfixingofslimboxfitting,madeoutofCRCASheetmetalbodywithlockingtypeholdercompletelywired.ExcludingBallast & Fluorescent Tube. 1 x 4' Tube light fitting. | No | 361.0 | 361.0 | 4.0 | False | None | None | False | None | False | 1444.0 | 0 | | 2879040 | 94100 | None | 13.1.1 | SupplyingandFixingof.mmdiaclassAGIpipebracketupto2mslongbentatsuitableangleandfixingtothisbracketstreetlightfittingofallcapacitiestoGIorGIorrailorRCpole/wallusingsuitableclamps,bolts,andnutsandw | No | 978.0 | 978.0 | 1.0 | False | None | None | False | None | False | 978.0 | 0 | | 2879041 | 94100 | None | I. No.2.3.2,3.2.2.3,3.235.4) | Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010 1.5 Sqm | Mtr | 26.0 | 26.0 | 25.0 | False | None | None | False | None | False | 650.0 | 0 | | 2879042 | 94100 | None | I. No.2.3.2,3.2.2.3,3.235.4) | Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010 2.5 Sqm | Mtr | 42.0 | 42.0 | 25.0 | False | None | None | False | None | False | 1050.0 | 0 | | 2879043 | 94100 | None | I. No.2.3.2,3.2.2.3,3.235.4) | Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010 4 sqm | Mtr | 63.0 | 63.0 | 25.0 | False | None | None | False | None | False | 1575.0 | 0 | | 2879044 | 94100 | None | Basic Rate | cleaning machin Stainless Steel Top Loading Sanitary Napkin Incinerator Machine, Burning Ability: 500 Kg/time | No | 24000.0 | 24000.0 | 1.0 | False | None | None | False | None | False | 24000.0 | 0 |
| | 1709347272000 | 0 | None | None | Buildings | Const of Water Tank Supplying and Fixing of RO Plant Electrfication Toilet Cleaning Machine to GHPS School at Kalakeri Village | 440738.98 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 2879045 | 94101 | None | Basic Rate | RO Water Plant for Hemodialysis 500 Ltrs/Hr Capacity Specifications Plant capacity (Ltrs/Hr) 500 Plant type Microprocessor/microcontroller controlled single stage RO water system ( Feed water TDS more than 500 PPM) System type Online ,Offline Double raw water pump ( one active and the other stand by) No Raw water feed pump capacity (LPH) 1500 Micron particle filter after activated Carbon filter for removing suspended particles more than micron size 5 Distribution of RO plant water sufficient for number of dialysis machines 5-10 Material of Booster pump (offline) Stainless Steel 316 | No | 160000.0 | 160000.0 | 1.0 | False | None | None | False | None | False | 160000.0 | 0 | | 2879046 | 94101 | None | 1.6.1 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required
to complete the work. | No | 508.2 | 508.2 | 35.0 | False | None | None | False | None | False | 17787.0 | 0 | | 2879047 | 94101 | None | 13.11.1 | Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. For 3 HP etc. complete. 3.00 HP - 300 LPM @ 26 m = 5 STG Outlet Dia - 2.50" | Each | 24326.4 | 24326.4 | 1.0 | False | None | None | False | None | False | 24326.4 | 0 | | 2879048 | 94101 | None | 9.1.1 | Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for
testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0 HDPE Grade PE80-PN6.0, 63mm dia | Mtr | 198.45 | 198.45 | 35.0 | False | None | None | False | None | False | 6945.75 | 0 | | 2879049 | 94101 | None | Basic Rate | Stainless Steel Top Loading Sanitary Napkin Incinerator Machine Burning Ability 500 kg Time | No | 24000.0 | 24000.0 | 1.0 | False | None | None | False | None | False | 24000.0 | 0 | | 2879050 | 94101 | None | 1.1.1 | Supplying and fixing sheet Metal box made out of 18 SWG sheet
metal with necessary holes for cable/conduit entry as required with one
coat of primer of approved make etc 75 x 75 x 65 mm | No | 106.0 | 106.0 | 8.0 | False | None | None | False | None | False | 848.0 | 0 | | 2879051 | 94101 | None | 2.2.1 | Supplying and wiring adopting loop system in existing PVC Conduit
/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral)
& 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated
copper wire (confirming to IS-694: and latest amendments) without
control switch shall be fixed on the existing plastic sheet/ gang box,
the other end of the wires shall be terminated with sufficient loose
length in a wood/PVC round block. complete for each outlet.
Short point upto 3Mtr from tapping point to out let via switch box | No | 285.0 | 285.0 | 8.0 | False | None | None | False | None | False | 2280.0 | 0 | | 2879052 | 94101 | None | 2.2.1 | Medium point above 3Mtr upto 6Mtr from tapping point to out let via
switch box | No | 394.0 | 394.0 | 8.0 | False | None | None | False | None | False | 3152.0 | 0 | | 2879053 | 94101 | None | 2.2.2 | Long point above 6Mtr upto 10Mtr from tapping point to out let via
switch box | No | 555.0 | 555.0 | 8.0 | False | None | None | False | None | False | 4440.0 | 0 | | 2879054 | 94101 | None | 3.8 | Supplying 4mm thick plastic sheet with necessary nitches for
fixing switches, regulators etc, and fixing on existing wooden or
metal box using N.F. screws | Sqm | 0.41 | 0.41 | 1500.0 | False | None | None | False | None | False | 615.0 | 0 | | 2879055 | 94101 | None | 3.1.2 | Supplying 6A flush type socket and 6 A flush type SP switch either
surface/flush mounting in existing gang box or in 4mm thick plastic
sheet and fixing over a flush mounted wooden box and wiring using
necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 Way | Each | 147.0 | 147.0 | 18.0 | False | None | None | False | None | False | 2646.0 | 0 | | 2879056 | 94101 | None | 6.3.1 | Supplying capacitor type ceiling fan complete with down rod blades,
shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase
AC supply conforming to ISS-374- 1979 and with double ball bearing
system 48" Sweep (1200 mm) Regular mode | No | 1900.0 | 1900.0 | 6.0 | False | None | None | False | None | False | 11400.0 | 0 | | 2879057 | 94101 | None | 11.13 | Supplying and fixing of slim patty fitting, made out of CRCA Sheet
metal body with locking type holder completely wired. Excluding
Ballast & Fluorescent Tube. | No | 361.0 | 361.0 | 8.0 | False | None | None | False | None | False | 2888.0 | 0 | | 2879058 | 94101 | None | 13.1.1 | Supplying and Fixing of.mm dia class A GI pipe bracket upto 2
ms long bent at suitable angle and fixing to this bracket street light
fitting of all capacities to GI or GI or rail or RCC pole / wall using
suitable clamps, bolts, and nuts and wiring using suitable capacity
wires. Using 25mm dia G.I.Pipe | No | 978.0 | 978.0 | 1.0 | False | None | None | False | None | False | 978.0 | 0 | | 2879059 | 94101 | None | 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 1.5 mm | m | 26.0 | 26.0 | 55.0 | False | None | None | False | None | False | 1430.0 | 0 | | 2879060 | 94101 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010
2.5 mm2 | m | 42.0 | 42.0 | 55.0 | False | None | None | False | None | False | 2310.0 | 0 | | 2879061 | 94101 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 4 mm2 | m | 63.0 | 63.0 | 55.0 | False | None | None | False | None | False | 3465.0 | 0 | | 2879062 | 94101 | None | 1.1.1 | SupplyingheavygaugePVCconduitpipe.dia.mmthickconfirmingtoIS2509withsuitablesizebends,junctionboxes,adhesivepasteetc,andfixingusinginvertedwoodplugsincaseofRCCceilingandRCCwall/stonestructureorrawlplugsincaseofbrickwallsandcementplasteringthedamagedportionusingheavygauge saddles at an interval of 700mm using NF screws. | Mtr | 69.0 | 69.0 | 55.0 | False | None | None | False | None | False | 3795.0 | 0 | | 2879063 | 94101 | None | 1.4 | Earth work excavation by manual means for drains, canals, waste weir, draft,
approach channels, key trenches, foundation of Buildings & bridges and such
simillar works in all kinds of soils, as per drawing and technical specifications,
including setting out, shoring, strutting, barricading, caution lights, removal
of stumps and other deleterious matter, excavated surface leveled and sides
neatly dressed disposing off the excavated stuff or sorting & stacking the
selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of
labour, tools & other appurtenaces required to complete the work. | Cum | 254.1 | 254.1 | 6.75 | False | None | None | False | None | False | 1715.175 | 0 | | 2879064 | 94101 | None | 2.1.1 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in
layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates work as per technical specifications | Cum | 5947.2 | 5947.2 | 1.4 | False | None | None | False | None | False | 8326.08 | 0 | | 2879065 | 94101 | None | 5.2 | Providing Coursed rubble masonry (first sort) with hard stone in foundation
and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6948.9 | 6948.9 | 1.5 | False | None | None | False | None | False | 10423.35 | 0 | | 2879066 | 94101 | None | 5.3 | Providing Coursed rubble masonry (second sort) with hard stone in
foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand | Cum | 6515.25 | 6515.25 | 1.2 | False | None | None | False | None | False | 7818.3 | 0 | | 2879067 | 94101 | None | 5.4 | Providing Size Stone masonry with hard stone in foundation & plinth with
Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6708.45 | 6708.45 | 2.7 | False | None | None | False | None | False | 18112.815 | 0 | | 2879068 | 94101 | None | 1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of
foundations and other similar works etc. in layers not exceeding 20cm in depth,
consolidating each deposited layer by ramming and watering, lead up to 50 m
and lift upto 1.5 m. | Cum | 279.3 | 279.3 | 3.6 | False | None | None | False | None | False | 1005.48 | 0 | | 2879069 | 94101 | None | 2.2.1 | Providing and laying in position Cement Concrete for all Foundation works.
The granite/trap/basalt crushed graded coarse aggregates and fine aggregates
as per relevant IS Codes machine mixed with super plasticizers laid in finished
layers, well compacted using needle vibrators, including all lead & lifts, cost
of all materials, quality confirming to the requirements of relevant IS codes,
labour, Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6601.35 | 6601.35 | 1.1 | False | None | None | False | None | False | 7261.485 | 0 | | 2879070 | 94101 | None | 2.5.1 | Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cum | Sqm | 3960.81 | 3960.81 | 0.35 | False | None | None | False | None | False | 1386.2835 | 0 | | 2879071 | 94101 | None | 2.5.1 | Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cum | Sqm | 3300.68 | 3300.68 | 0.75 | False | None | None | False | None | False | 2475.51 | 0 | | 2879072 | 94101 | None | 2.11 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement
including cost of all materials, machinery, labour, cleaning, straightening,
cutting, bending, hooking, laping/welding joints, tying with binding wire / soft
annealed steel wire and other ancilary operations complete as per drawing and
technical specification.
| Tonne | 93929.85 | 93929.85 | 0.1 | False | None | None | False | None | False | 9392.985 | 0 | | 2879073 | 94101 | None | 6.7 | Providing Brick work with common burnt clay Non Modular bricks of
class designation 3.5 in superstructure above plinth level in all shapes and
sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of
all materials, labour, scaffolding and usage charges of machinery & other
incidental charges complete as per the direction of engineer incharge of
work. | Cum | 8621.55 | 8621.55 | 4.14 | False | None | None | False | None | False | 35693.217 | 0 | | 2879074 | 94101 | None | 8.6.1 | Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3
coarse sand) finished with a floating coat of neat cement to brick masonry
including rounding off corners wherever required smooth rendering,
providing and removing scaffolding, including cost of materials, labour,
curing complete as per specifications and as per directions of Engineerin-charge. | Sqm | 339.15 | 339.15 | 51.0 | False | None | None | False | None | False | 17296.65 | 0 | | 2879075 | 94101 | None | 8.40 | Painting with synthetic enamel paint of approved brand and
manufacture to give an even shade :Two coats on new work after
thoroughly brooming the surface to remove all dirt, dust, mortar drops
and foreign matter including preparing the surface even and sand paper
smooth, cost of materials, labour complete as per specifications and as per
directions of Engineer-in-charge. | Sqm | 120.75 | 120.75 | 51.0 | False | None | None | False | None | False | 6158.25 | 0 | | 2879076 | 94101 | None | 13.2.1 | Providing and fixing brass bib cock of approved quality : | Each | 300.3 | 300.3 | 5.0 | False | None | None | False | None | False | 1501.5 | 0 | | 2879077 | 94101 | None | 1.6.1 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required
to complete the work. | No | 508.2 | 508.2 | 55.0 | False | None | None | False | None | False | 27951.0 | 0 | | 2879078 | 94101 | None | 9.1.1 | Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for
testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0 HDPE Grade PE80-PN6.0, 63mm dia | Mtr | 198.45 | 198.45 | 55.0 | False | None | None | False | None | False | 10914.75 | 0 |
| | 1709347272000 | 0 | None | None | Buildings | Construction of Room Repairs of Electrfication and Supplying of Toilet Cleaning Machine at GHPS at Musalapur Village | 1594646.08 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 2879079 | 94102 | None | 1.4 | Earth work excavation by manual means for drains, canals, waste weir, draft,
approach channels, key trenches, foundation of Buildings & bridges and such
simillar works in all kinds of soils, as per drawing and technical specifications,
including setting out, shoring, strutting, barricading, caution lights, removal
of stumps and other deleterious matter, excavated surface leveled and sides
neatly dressed disposing off the excavated stuff or sorting & stacking the
selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of
labour, tools & other appurtenaces required to complete the work. | Cum | 254.1 | 254.1 | 41.513 | False | None | None | False | None | False | 10548.4533 | 0 | | 2879080 | 94102 | None | 2.1.1 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in
layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates work as per technical specifications | Cum | 5947.2 | 5947.2 | 12.72 | False | None | None | False | None | False | 75648.384 | 0 | | 2879081 | 94102 | None | 5.2 | Providing Coursed rubble masonry (first sort) with hard stone in foundation
and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6948.9 | 6948.9 | 11.31 | False | None | None | False | None | False | 78592.059 | 0 | | 2879082 | 94102 | None | 5.3 | Providing Coursed rubble masonry (second sort) with hard stone in
foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand | Cum | 6515.25 | 6515.25 | 8.11 | False | None | None | False | None | False | 52838.6775 | 0 | | 2879083 | 94102 | None | 5.4 | Providing Size Stone masonry with hard stone in foundation & plinth with
Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6708.45 | 6708.45 | 12.3 | False | None | None | False | None | False | 82513.935 | 0 | | 2879084 | 94102 | None | 1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of
foundations and other similar works etc. in layers not exceeding 20cm in depth,
consolidating each deposited layer by ramming and watering, lead up to 50 m
and lift upto 1.5 m. | Cum | 279.3 | 279.3 | 45.9 | False | None | None | False | None | False | 12819.87 | 0 | | 2879085 | 94102 | None | 2.2.1 | Providing and laying in position Cement Concrete for all Foundation works.
The granite/trap/basalt crushed graded coarse aggregates and fine aggregates
as per relevant IS Codes machine mixed with super plasticizers laid in finished
layers, well compacted using needle vibrators, including all lead & lifts, cost
of all materials, quality confirming to the requirements of relevant IS codes,
labour, Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6601.35 | 6601.35 | 26.33 | False | None | None | False | None | False | 173813.5455 | 0 | | 2879086 | 94102 | None | 2.5.1 | Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cum | Sqm | 330.07 | 330.07 | 1.73 | False | None | None | False | None | False | 571.0211 | 0 | | 2879087 | 94102 | None | 2.5.1 | Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cum | Sqm | 660.14 | 660.14 | 2.73 | False | None | None | False | None | False | 1802.1822 | 0 | | 2879088 | 94102 | None | 2.5.1 | Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cum | Sqm | 3960.81 | 3960.81 | 5.76 | False | None | None | False | None | False | 22814.2656 | 0 | | 2879089 | 94102 | None | 2.5.1 | Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cum | Sqm | 3300.68 | 3300.68 | 13.1 | False | None | None | False | None | False | 43238.908 | 0 | | 2879090 | 94102 | None | 2.11 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement
including cost of all materials, machinery, labour, cleaning, straightening,
cutting, bending, hooking, laping/welding joints, tying with binding wire / soft
annealed steel wire and other ancilary operations complete as per drawing and
technical specification.
| Tonne | 93929.85 | 93929.85 | 2.75 | False | None | None | False | None | False | 258307.0875 | 0 | | 2879091 | 94102 | None | 6.7 | Providing Brick work with common burnt clay Non Modular bricks of
class designation 3.5 in superstructure above plinth level in all shapes and
sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of
all materials, labour, scaffolding and usage charges of machinery & other
incidental charges complete as per the direction of engineer incharge of
work. | Cum | 8621.55 | 8621.55 | 19.64 | False | None | None | False | None | False | 169327.242 | 0 | | 2879092 | 94102 | None | 11.34B | Providing and fixing M.S. grills of required pattern in frames of windows
etc. with M.S. flats, square or round bars etc. including priming coat with
approved steel primer all complete. Fixed to openings /wooden frames
with rawl plugs screws etc. | Sqm | 192.15 | 192.15 | 177.66 | False | None | None | False | None | False | 34137.369 | 0 | | 2879093 | 94102 | None | 8.6.1 | Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3
coarse sand) finished with a floating coat of neat cement to brick masonry
including rounding off corners wherever required smooth rendering,
providing and removing scaffolding, including cost of materials, labour,
curing complete as per specifications and as per directions of Engineerin-charge. | Sqm | 339.15 | 339.15 | 84.78 | False | None | None | False | None | False | 28753.137 | 0 | | 2879094 | 94102 | None | 8.7 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement:
3 coarse sand) finished with a floating coat of neat cement on the rough
side of single or half brick wall including rounding off corners wherever
required smooth rendering, providing and removing scaffolding, including
cost of materials, labour, curing complete as per specifications and as per
directions of Engineer-in-charge | Sqm | 279.3 | 279.3 | 115.38 | False | None | None | False | None | False | 32225.634 | 0 | | 2879095 | 94102 | None | 8.33.1 | Finishing with Deluxe Multi surface paint system for interiors and exteriors
using Primer as per manufacturers specifications: Two coats applied on
walls @ 1.25 L/10 m² over and including one coat of Special primer applied
@ 0.75 L/10 m² with paint of approved quality to give an even shade, after
thoroughly brooming the surface to remove all dirt, dust, mortar drops
and foreign matter including preparing the surface even and sand paper
smooth, cost of materials, labour complete as per specifications and as per
directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree
angle with 10 years life) | Sqm | 165.9 | 165.9 | 84.78 | False | None | None | False | None | False | 14065.002 | 0 | | 2879096 | 94102 | None | 8.29 | Finishing walls with textured exterior paint of required shade :New work
(Two coats applied @ 3.28 L/10 m²) over and including priming coat of
exterior primer applied @ 2.20kg/10 m² to give an even shade after
thoroughly brooming the surface to remove all dirt, dust, mortar drops
and foreign matter including preparing the surface even and sand paper
smooth, cost of materials, labour complete as per specifications and as per
directions of Engineer-in-charge. | Sqm | 297.15 | 297.15 | 115.38 | False | None | None | False | None | False | 34285.167 | 0 | | 2879097 | 94102 | None | 9.12.2 | Providing and laying vitrified floor tiles with thickness 9-10 mm in
different sizes with water absorption less than 0.08% and conforming to
IS: 15622, of approved make, in all colours and shades, laid on 20mm thick
cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement
slurry @ 3.3 kg/ m2 including grouting the joints with white cement and
matching pigments etc., complete.Size of Tile 600x600 mm | Sqm | 1202.25 | 1202.25 | 57.8 | False | None | None | False | None | False | 69490.05 | 0 | | 2879098 | 94102 | None | 9.34 | Flooring with 25mm thick polished tandur blue stone slabs using cement
mortar 1:6, 25mm thick over existing cement concrete bed or top of roof
laid to line and level and jointed with cement slurry mixed with pigment
to match the shade of the slab, , including cost of materials, labour,
curing, polishing complete as per specifications | Sqm | 1622.25 | 1622.25 | 18.7 | False | None | None | False | None | False | 30336.075 | 0 | | 2879099 | 94102 | None | 12.12 | Providing Mathi/Nandi wood frames of doors, windows, clerestory
windows, ventilators and other frames, wrought, framed or assembled
including making plaster groves (excluding cost of cement concrete and side
clamps ), but including cost of materials, labour, usage charges complete
as per specifications.
| Cum | 130412.1 | 130412.1 | 0.24 | False | None | None | False | None | False | 31298.904 | 0 | | 2879100 | 94102 | None | 12.15 | Providing and fixing in position fully panelled Honne wood shutters for
doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm
wide top rail and stiles 100mm wide as per drawing and panels of 25mm
thick including cost of materials, labour, usage charges complete as per
specifications. ( excluding cost of fixtures ) | Sqm | 7816.2 | 7816.2 | 8.28 | False | None | None | False | None | False | 64718.136 | 0 | | 2879101 | 94102 | None | 8.49 | Lettering with black Japan paint of approved brand and manufacture to give
an even shade including preparing the surface after thoroughly cleaning the
surface to remove all dirt, dust and foreign matter, cost of materials, labour
complete as per specifications and as per directions of Engineer-in-charge | No | 4.2 | 4.2 | 7000.0 | False | None | None | False | None | False | 29400.0 | 0 | | 2879102 | 94102 | None | 88.84 | Providing Wall black in 12 mm thick with CM 1:3 and applied with primer and two coats of acyrlic emulsion black paint including finishing etc complete | Sqm | 498.75 | 498.75 | 3.6 | False | None | None | False | None | False | 1795.5 | 0 | | 2879103 | 94102 | None | 12.80 | Providing and Fixing door latch with necessary screws etc complete | Sqm | 299.25 | 299.25 | 3.6 | False | None | None | False | None | False | 1077.3 | 0 | | 2879104 | 94102 | None | 20.27.3 | Providing and Fixing bright finished brass flush bolts with necessary brass screws etc cpmplete | Each | 172.2 | 172.2 | 22.0 | False | None | None | False | None | False | 3788.4 | 0 | | 2879105 | 94102 | None | 1.1.1 | Electrification:Supplying heavy gauge PVC conduit pipe . dia . mm thick
confirming to IS 2509 with suitable size bends, junction boxes,
adhesive paste etc , and fixing using inverted wood plugs in case of
RCC ceiling and RCC wall/ stone structure or rawl plugs in case of
brick walls and cement plastering the damaged portion using heavy
gauge saddles at an interval of 700mm using NF screws.19/20 mm dia 2 mm thick | Mtr | 69.0 | 69.0 | 40.0 | False | None | None | False | None | False | 2760.0 | 0 | | 2879106 | 94102 | None | 1.4.1 | Supplying and fixing sheet Metal box made out of 18 SWG sheet
metal with necessary holes for cable/conduit entry as required with one
coat of primer of approved make etc 75 x 75 x 65 mm | Nos | 106.0 | 106.0 | 4.0 | False | None | None | False | None | False | 424.0 | 0 | | 2879107 | 94102 | None | 2.2.1 | Supplying and wiring adopting loop system in existing PVC Conduit
/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral)
& 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated
copper wire (confirming to IS-694: and latest amendments) without
control switch shall be fixed on the existing plastic sheet/ gang box,
the other end of the wires shall be terminated with sufficient loose
length in a wood/PVC round block. complete for each outlet.Short point upto 3Mtr from tapping point to out let via switch box | Nos | 285.0 | 285.0 | 4.0 | False | None | None | False | None | False | 1140.0 | 0 | | 2879108 | 94102 | None | 2.2.3 | Medium point above 3Mtr upto 6Mtr from tapping point to out let via
switch box | Nos | 394.0 | 394.0 | 4.0 | False | None | None | False | None | False | 1576.0 | 0 | | 2879109 | 94102 | None | 2.2.3 | Long point above 6Mtr upto 10Mtr from tapping point to out let via
switch box | Nos | 555.0 | 555.0 | 4.0 | False | None | None | False | None | False | 2220.0 | 0 | | 2879110 | 94102 | None | 3.8 | Supplying 4mm thick plastic sheet with necessary nitches for
fixing switches, regulators etc, and fixing on existing wooden or
metal box using N.F. screws. | Sqm | 0.41 | 0.41 | 1500.0 | False | None | None | False | None | False | 615.0 | 0 | | 2879111 | 94102 | None | 3.1.2 | Supplying 6A flush type socket and 6 A flush type SP switch either
surface/flush mounting in existing gang box or in 4mm thick plastic
sheet and fixing over a flush mounted wooden box and wiring using
necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 Way | Nos | 147.0 | 147.0 | 16.0 | False | None | None | False | None | False | 2352.0 | 0 | | 2879112 | 94102 | None | 12.60 | Supplying & Fixing Chemical earthling for grounding. Conduits, IC
cut-outs & other equipments backfill compound which is noncorrosive, thermally conductive, potential to permissible limits,
superior Fault conduction capacity, non toxic, weather resistance &
capable of achieving ohmic value less than one ohm Using 4ft. Copper bonded rod with backfill compound | Nos | 4528.0 | 4528.0 | 1.0 | False | None | None | False | None | False | 4528.0 | 0 | | 2879113 | 94102 | None | 6.3 | Supplying capacitor type ceiling fan complete with down rod blades,
shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase
AC supply conforming to ISS-374- 1979 and with double ball bearing
system | Nos | 1900.0 | 1900.0 | 2.0 | False | None | None | False | None | False | 3800.0 | 0 | | 2879114 | 94102 | None | 11.14.2 | Supplying and fixing of slim box fitting, made out of CRCA Sheet
metal body with locking type holder completely wired. Excluding
Ballast & Fluorescent Tube 1 x 4' Tube light fitting | Nos | 361.0 | 361.0 | 4.0 | False | None | None | False | None | False | 1444.0 | 0 | | 2879115 | 94102 | None | 13.1.1 | Supplying and Fixing of.mm dia class A GI pipe bracket upto 2
ms long bent at suitable angle and fixing to this bracket street light
fitting of all capacities to GI or GI or rail or RCC pole / wall using
suitable clamps, bolts, and nuts and wiring using suitable capacity
wires Using 25mm dia G.I.Pipe | Nos | 978.0 | 978.0 | 1.0 | False | None | None | False | None | False | 978.0 | 0 | | 2879116 | 94102 | None | P No 23 | Pre - Paid Energy Meter Single Phase, 5-30 Amps, 1.0
Accuracy Class with Key Pad Technology consumer
interface unit along with pillfer proof box | No | 7170.0 | 7170.0 | 1.0 | False | None | None | False | None | False | 7170.0 | 0 | | 2879117 | 94102 | None | P No 6 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010
1.5 mm | Mtr | 26.0 | 26.0 | 40.0 | False | None | None | False | None | False | 1040.0 | 0 | | 2879118 | 94102 | None | P No 6 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 2.5 mm | Mtr | 42.0 | 42.0 | 40.0 | False | None | None | False | None | False | 1680.0 | 0 | | 2879119 | 94102 | None | P No 6 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:20104 mm2 | Mtr | 63.0 | 63.0 | 40.0 | False | None | None | False | None | False | 2520.0 | 0 | | 2879120 | 94102 | None | 8.33.1 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign atter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 165.9 | 165.9 | 72.0 | False | None | None | False | None | False | 11944.8 | 0 | | 2879121 | 94102 | None | 19.22 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction
of Engineer-in-charge | Cum | 50.4 | 50.4 | 81.2 | False | None | None | False | None | False | 4092.48 | 0 | | 2879122 | 94102 | None | 2.1.1 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required t complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M7.5) Using 40 mm nominal size graded crushed coarse aggregates
| Cum | 5947.2 | 5947.2 | 8.12 | False | None | None | False | None | False | 48291.264 | 0 | | 2879123 | 94102 | None | 9.12.2 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grou ting the joints with white cement and matching pigments etc., complete. (Size of Tile 600x600 mm) | Sqm | 1202.25 | 1202.25 | 86.32 | False | None | None | False | None | False | 103778.22 | 0 | | 2879124 | 94102 | None | 1.1.1 | SupplyingheavygaugePVCconduitpipe.dia.mmthickconfirmingtoIS2509withsuitablesizebends,junctionboxes,adhesivepasteetc,andfixingusinginvertedwoodplugsincaseofRCCceilingandRCCwall/stonestructureorrawlplugsincaseofbrickwallsandcementplasteringthedamagedportionusingheavygauge saddles at an interval of 700mm using NF screws. | Mtr | 69.0 | 69.0 | 20.0 | False | None | None | False | None | False | 1380.0 | 0 | | 2879125 | 94102 | None | Basic Rate | Stainless Steel Top Loading Sanitary Napkin Incinerator Machine Burning Ability 500 kg Time | No | 24000.0 | 24000.0 | 1.0 | False | None | None | False | None | False | 24000.0 | 0 | | 2879126 | 94102 | None | 1.1.1 | Supplying and fixing sheet Metal box made out of 18 SWG sheet
metal with necessary holes for cable/conduit entry as required with one
coat of primer of approved make etc 75 x 75 x 65 mm | No | 106.0 | 106.0 | 2.0 | False | None | None | False | None | False | 212.0 | 0 | | 2879127 | 94102 | None | 2.2.1 | Supplying and wiring adopting loop system in existing PVC Conduit
/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral)
& 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated
copper wire (confirming to IS-694: and latest amendments) without
control switch shall be fixed on the existing plastic sheet/ gang box,
the other end of the wires shall be terminated with sufficient loose
length in a wood/PVC round block. complete for each outlet.
Short point upto 3Mtr from tapping point to out let via switch box | No | 285.0 | 285.0 | 2.0 | False | None | None | False | None | False | 570.0 | 0 | | 2879128 | 94102 | None | 2.2.1 | Medium point above 3Mtr upto 6Mtr from tapping point to out let via
switch box | No | 394.0 | 394.0 | 2.0 | False | None | None | False | None | False | 788.0 | 0 | | 2879129 | 94102 | None | 2.2.2 | Long point above 6Mtr upto 10Mtr from tapping point to out let via
switch box | No | 555.0 | 555.0 | 2.0 | False | None | None | False | None | False | 1110.0 | 0 | | 2879130 | 94102 | None | 3.8 | Supplying 4mm thick plastic sheet with necessary nitches for
fixing switches, regulators etc, and fixing on existing wooden or
metal box using N.F. screws | Sqm | 0.41 | 0.41 | 1000.0 | False | None | None | False | None | False | 410.0 | 0 | | 2879131 | 94102 | None | 3.1.2 | Supplying 6A flush type socket and 6 A flush type SP switch either
surface/flush mounting in existing gang box or in 4mm thick plastic
sheet and fixing over a flush mounted wooden box and wiring using
necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 Way | Each | 147.0 | 147.0 | 5.0 | False | None | None | False | None | False | 735.0 | 0 | | 2879132 | 94102 | None | 6.3.1 | Supplying capacitor type ceiling fan complete with down rod blades,
shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase
AC supply conforming to ISS-374- 1979 and with double ball bearing
system 48" Sweep (1200 mm) Regular mode | No | 1900.0 | 1900.0 | 1.0 | False | None | None | False | None | False | 1900.0 | 0 | | 2879133 | 94102 | None | 11.13 | Supplying and fixing of slim patty fitting, made out of CRCA Sheet
metal body with locking type holder completely wired. Excluding
Ballast & Fluorescent Tube. | No | 361.0 | 361.0 | 1.0 | False | None | None | False | None | False | 361.0 | 0 | | 2879134 | 94102 | None | 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 1.5 mm | m | 26.0 | 26.0 | 20.0 | False | None | None | False | None | False | 520.0 | 0 | | 2879135 | 94102 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010
2.5 mm2 | m | 42.0 | 42.0 | 20.0 | False | None | None | False | None | False | 840.0 | 0 | | 2879136 | 94102 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 4 mm2 | m | 63.0 | 63.0 | 20.0 | False | None | None | False | None | False | 1260.0 | 0 |
| | 1709347272000 | 0 | None | None | Buildings | Repairs of 2 Room Building Electrification and Supplying of Toilet Cleaning Machine at GHPS School at Hirekhed Village | 370648.8 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 2879137 | 94103 | None | 8.72.1 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign atter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 91.35 | 91.35 | 227.1 | False | None | None | False | None | False | 20745.585 | 0 | | 2879138 | 94103 | None | 15.2 | Providing and Applying PU based Elastomeric Liquid Applied PU
Waterproofing Membrane single component, cold applied, water based
acrylic PU dispersion with highly elastic and UV resistant water proofing
treatment to the Existing Roof surface/Chajjas/Sunken portion of
WC:Bathroom applied @ 1.2 l/per m2, having tensile strength greater than
1.5N/mm2, elongation greater than 300% with solid content not less than
60% in 2 coats including surface preparation, priming the surface with
water based acrylic primer @0.1 l/m2, and spreading 60 gsm geotextile
between two top coats completely as per specification. The finished cost
to include surface preparation, making coving at Junction, Bore Packing,
treatment of construction joints completely as per specification. | Sqm | 773.85 | 773.85 | 130.9 | False | None | None | False | None | False | 101296.965 | 0 | | 2879139 | 94103 | None | 19.22 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction
of Engineer-in-charge | Cum | 50.4 | 50.4 | 96.2 | False | None | None | False | None | False | 4848.48 | 0 | | 2879140 | 94103 | None | 2.1.1 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required t complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M7.5) Using 40 mm nominal size graded crushed coarse aggregates
| Cum | 5947.2 | 5947.2 | 12.03 | False | None | None | False | None | False | 71544.816 | 0 | | 2879141 | 94103 | None | 9.12.2 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grou ting the joints with white cement and matching pigments etc., complete. (Size of Tile 600x600 mm) | Sqm | 1202.25 | 1202.25 | 101.76 | False | None | None | False | None | False | 122340.96 | 0 | | 2879142 | 94103 | None | Basic Rate | Stainless Steel Top Loading Sanitary Napkin Incinerator Machine Burning Ability 500 kg Time | No | 24000.0 | 24000.0 | 1.0 | False | None | None | False | None | False | 24000.0 | 0 | | 2879143 | 94103 | None | 1.1.1 | Supplying and fixing sheet Metal box made out of 18 SWG sheet
metal with necessary holes for cable/conduit entry as required with one
coat of primer of approved make etc 75 x 75 x 65 mm | No | 106.0 | 106.0 | 4.0 | False | None | None | False | None | False | 424.0 | 0 | | 2879144 | 94103 | None | 2.2.1 | Supplying and wiring adopting loop system in existing PVC Conduit
/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral)
& 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated
copper wire (confirming to IS-694: and latest amendments) without
control switch shall be fixed on the existing plastic sheet/ gang box,
the other end of the wires shall be terminated with sufficient loose
length in a wood/PVC round block. complete for each outlet.
Short point upto 3Mtr from tapping point to out let via switch box | No | 285.0 | 285.0 | 4.0 | False | None | None | False | None | False | 1140.0 | 0 | | 2879145 | 94103 | None | 2.2.1 | Medium point above 3Mtr upto 6Mtr from tapping point to out let via
switch box | No | 394.0 | 394.0 | 4.0 | False | None | None | False | None | False | 1576.0 | 0 | | 2879146 | 94103 | None | 2.2.2 | Long point above 6Mtr upto 10Mtr from tapping point to out let via
switch box | No | 555.0 | 555.0 | 4.0 | False | None | None | False | None | False | 2220.0 | 0 | | 2879147 | 94103 | None | 3.8 | Supplying 4mm thick plastic sheet with necessary nitches for
fixing switches, regulators etc, and fixing on existing wooden or
metal box using N.F. screws | Sqm | 0.41 | 0.41 | 1000.0 | False | None | None | False | None | False | 410.0 | 0 | | 2879148 | 94103 | None | 3.1.2 | Supplying 6A flush type socket and 6 A flush type SP switch either
surface/flush mounting in existing gang box or in 4mm thick plastic
sheet and fixing over a flush mounted wooden box and wiring using
necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 Way | Each | 147.0 | 147.0 | 5.0 | False | None | None | False | None | False | 735.0 | 0 | | 2879149 | 94103 | None | 6.3.1 | Supplying capacitor type ceiling fan complete with down rod blades,
shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase
AC supply conforming to ISS-374- 1979 and with double ball bearing
system 48" Sweep (1200 mm) Regular mode | No | 1900.0 | 1900.0 | 7.0 | False | None | None | False | None | False | 13300.0 | 0 | | 2879150 | 94103 | None | 11.13 | Supplying and fixing of slim patty fitting, made out of CRCA Sheet
metal body with locking type holder completely wired. Excluding
Ballast & Fluorescent Tube. | No | 361.0 | 361.0 | 2.0 | False | None | None | False | None | False | 722.0 | 0 | | 2879151 | 94103 | None | 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 1.5 mm | m | 26.0 | 26.0 | 25.0 | False | None | None | False | None | False | 650.0 | 0 | | 2879152 | 94103 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010
2.5 mm2 | m | 42.0 | 42.0 | 25.0 | False | None | None | False | None | False | 1050.0 | 0 | | 2879153 | 94103 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 4 mm2 | m | 63.0 | 63.0 | 25.0 | False | None | None | False | None | False | 1575.0 | 0 | | 2879154 | 94103 | None | 1.1.1 | SupplyingheavygaugePVCconduitpipe.dia.mmthickconfirmingtoIS2509withsuitablesizebends,junctionboxes,adhesivepasteetc,andfixingusinginvertedwoodplugsincaseofRCCceilingandRCCwall/stonestructureorrawlplugsincaseofbrickwallsandcementplasteringthedamagedportionusingheavygauge saddles at an interval of 700mm using NF screws. | Mtr | 69.0 | 69.0 | 30.0 | False | None | None | False | None | False | 2070.0 | 0 |
| | 1709347272000 | 0 | None | None | Buildings | Repairs of Building and Supplying of Toilet Cleaning Machine at KPS School at Karatagi Village | 191309.02 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 2879155 | 94104 | None | 19.22 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction
of Engineer-in-charge | Cum | 50.4 | 50.4 | 96.0 | False | None | None | False | None | False | 4838.4 | 0 | | 2879156 | 94104 | None | 2.1.1 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required t complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M7.5) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 6.78 | False | None | None | False | None | False | 40322.016 | 0 | | 2879157 | 94104 | None | 9.12.2 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grou ting the joints with white cement and matching pigments etc., complete. (Size of Tile 600x600 mm) | Sqm | 1202.25 | 1202.25 | 101.6 | False | None | None | False | None | False | 122148.6 | 0 | | 2879158 | 94104 | None | Basic Rate | Stainless Steel Top Loading Sanitary Napkin Incinerator Machine Burning ability 500 Kg | No | 24000.0 | 24000.0 | 1.0 | False | None | None | False | None | False | 24000.0 | 0 |
| | 1709347272000 | 0 | None | None | Buildings | Repairs of Room Const of Water Tank Supplying and Reapirs of Electrfication Toilet Cleaning Machine to Govt School at Hirekhed Village | 352850.59 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 2879159 | 94105 | None | 8.33.1 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign atter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 165.9 | 165.9 | 72.0 | False | None | None | False | None | False | 11944.8 | 0 | | 2879160 | 94105 | None | 19.22 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction
of Engineer-in-charge | Cum | 50.4 | 50.4 | 81.2 | False | None | None | False | None | False | 4092.48 | 0 | | 2879161 | 94105 | None | 2.1.1 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required t complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M7.5) Using 40 mm nominal size graded crushed coarse aggregates
| Cum | 5947.2 | 5947.2 | 8.12 | False | None | None | False | None | False | 48291.264 | 0 | | 2879162 | 94105 | None | 9.12.2 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grou ting the joints with white cement and matching pigments etc., complete. (Size of Tile 600x600 mm) | Sqm | 1202.25 | 1202.25 | 86.32 | False | None | None | False | None | False | 103778.22 | 0 | | 2879163 | 94105 | None | 1.1.1 | Supplying and fixing sheet Metal box made out of 18 SWG sheet
metal with necessary holes for cable/conduit entry as required with one
coat of primer of approved make etc 75 x 75 x 65 mm | No | 106.0 | 106.0 | 4.0 | False | None | None | False | None | False | 424.0 | 0 | | 2879164 | 94105 | None | 2.2.1 | Supplying and wiring adopting loop system in existing PVC Conduit
/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral)
& 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated
copper wire (confirming to IS-694: and latest amendments) without
control switch shall be fixed on the existing plastic sheet/ gang box,
the other end of the wires shall be terminated with sufficient loose
length in a wood/PVC round block. complete for each outlet.
Short point upto 3Mtr from tapping point to out let via switch box | No | 285.0 | 285.0 | 2.0 | False | None | None | False | None | False | 570.0 | 0 | | 2879165 | 94105 | None | 2.2.1 | Medium point above 3Mtr upto 6Mtr from tapping point to out let via
switch box | No | 394.0 | 394.0 | 2.0 | False | None | None | False | None | False | 788.0 | 0 | | 2879166 | 94105 | None | 2.2.2 | Long point above 6Mtr upto 10Mtr from tapping point to out let via
switch box | No | 555.0 | 555.0 | 2.0 | False | None | None | False | None | False | 1110.0 | 0 | | 2879167 | 94105 | None | 3.8 | Supplying 4mm thick plastic sheet with necessary nitches for
fixing switches, regulators etc, and fixing on existing wooden or
metal box using N.F. screws | Sqm | 0.41 | 0.41 | 1000.0 | False | None | None | False | None | False | 410.0 | 0 | | 2879168 | 94105 | None | 3.1.2 | Supplying 6A flush type socket and 6 A flush type SP switch either
surface/flush mounting in existing gang box or in 4mm thick plastic
sheet and fixing over a flush mounted wooden box and wiring using
necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 Way | Each | 147.0 | 147.0 | 5.0 | False | None | None | False | None | False | 735.0 | 0 | | 2879169 | 94105 | None | 6.3.1 | Supplying capacitor type ceiling fan complete with down rod blades,
shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase
AC supply conforming to ISS-374- 1979 and with double ball bearing
system 48" Sweep (1200 mm) Regular mode | No | 1900.0 | 1900.0 | 4.0 | False | None | None | False | None | False | 7600.0 | 0 | | 2879170 | 94105 | None | 11.13 | Supplying and fixing of slim patty fitting, made out of CRCA Sheet
metal body with locking type holder completely wired. Excluding
Ballast & Fluorescent Tube. | No | 361.0 | 361.0 | 2.0 | False | None | None | False | None | False | 722.0 | 0 | | 2879171 | 94105 | None | 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 1.5 mm | m | 26.0 | 26.0 | 22.0 | False | None | None | False | None | False | 572.0 | 0 | | 2879172 | 94105 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010
2.5 mm2 | m | 42.0 | 42.0 | 22.0 | False | None | None | False | None | False | 924.0 | 0 | | 2879173 | 94105 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 4 mm2 | m | 63.0 | 63.0 | 22.0 | False | None | None | False | None | False | 1386.0 | 0 | | 2879174 | 94105 | None | 1.4 | Earth work excavation by manual means for drains, canals, waste weir, draft,
approach channels, key trenches, foundation of Buildings & bridges and such
simillar works in all kinds of soils, as per drawing and technical specifications,
including setting out, shoring, strutting, barricading, caution lights, removal
of stumps and other deleterious matter, excavated surface leveled and sides
neatly dressed disposing off the excavated stuff or sorting & stacking the
selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of
labour, tools & other appurtenaces required to complete the work. | Cum | 254.1 | 254.1 | 6.75 | False | None | None | False | None | False | 1715.175 | 0 | | 2879175 | 94105 | None | 1.1.1 | SupplyingheavygaugePVCconduitpipe.dia.mmthickconfirmingtoIS2509withsuitablesizebends,junctionboxes,adhesivepasteetc,andfixingusinginvertedwoodplugsincaseofRCCceilingandRCCwall/stonestructureorrawlplugsincaseofbrickwallsandcementplasteringthedamagedportionusingheavygauge saddles at an interval of 700mm using NF screws. | Mtr | 69.0 | 69.0 | 30.0 | False | None | None | False | None | False | 2070.0 | 0 | | 2879176 | 94105 | None | 2.1.1 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in
layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates work as per technical specifications | Cum | 5947.2 | 5947.2 | 1.4 | False | None | None | False | None | False | 8326.08 | 0 | | 2879177 | 94105 | None | 5.2 | Providing Coursed rubble masonry (first sort) with hard stone in foundation
and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6948.9 | 6948.9 | 1.5 | False | None | None | False | None | False | 10423.35 | 0 | | 2879178 | 94105 | None | 5.3 | Providing Coursed rubble masonry (second sort) with hard stone in
foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand | Cum | 6515.25 | 6515.25 | 1.2 | False | None | None | False | None | False | 7818.3 | 0 | | 2879179 | 94105 | None | 5.4 | Providing Size Stone masonry with hard stone in foundation & plinth with
Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6708.45 | 6708.45 | 2.7 | False | None | None | False | None | False | 18112.815 | 0 | | 2879180 | 94105 | None | 1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of
foundations and other similar works etc. in layers not exceeding 20cm in depth,
consolidating each deposited layer by ramming and watering, lead up to 50 m
and lift upto 1.5 m. | Cum | 279.3 | 279.3 | 3.6 | False | None | None | False | None | False | 1005.48 | 0 | | 2879181 | 94105 | None | 2.2.1 | Providing and laying in position Cement Concrete for all Foundation works.
The granite/trap/basalt crushed graded coarse aggregates and fine aggregates
as per relevant IS Codes machine mixed with super plasticizers laid in finished
layers, well compacted using needle vibrators, including all lead & lifts, cost
of all materials, quality confirming to the requirements of relevant IS codes,
labour, Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6601.35 | 6601.35 | 1.1 | False | None | None | False | None | False | 7261.485 | 0 | | 2879182 | 94105 | None | 2.5.1 | Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cum | Sqm | 3960.81 | 3960.81 | 0.35 | False | None | None | False | None | False | 1386.2835 | 0 | | 2879183 | 94105 | None | 2.5.1 | Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cum | Sqm | 3300.68 | 3300.68 | 0.75 | False | None | None | False | None | False | 2475.51 | 0 | | 2879184 | 94105 | None | 2.11 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement
including cost of all materials, machinery, labour, cleaning, straightening,
cutting, bending, hooking, laping/welding joints, tying with binding wire / soft
annealed steel wire and other ancilary operations complete as per drawing and
technical specification.
| Tonne | 93929.85 | 93929.85 | 0.1 | False | None | None | False | None | False | 9392.985 | 0 | | 2879185 | 94105 | None | 6.7 | Providing Brick work with common burnt clay Non Modular bricks of
class designation 3.5 in superstructure above plinth level in all shapes and
sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of
all materials, labour, scaffolding and usage charges of machinery & other
incidental charges complete as per the direction of engineer incharge of
work. | Cum | 8621.55 | 8621.55 | 4.14 | False | None | None | False | None | False | 35693.217 | 0 | | 2879186 | 94105 | None | 8.6.1 | Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3
coarse sand) finished with a floating coat of neat cement to brick masonry
including rounding off corners wherever required smooth rendering,
providing and removing scaffolding, including cost of materials, labour,
curing complete as per specifications and as per directions of Engineerin-charge. | Sqm | 339.15 | 339.15 | 51.0 | False | None | None | False | None | False | 17296.65 | 0 | | 2879187 | 94105 | None | 8.40 | Painting with synthetic enamel paint of approved brand and
manufacture to give an even shade :Two coats on new work after
thoroughly brooming the surface to remove all dirt, dust, mortar drops
and foreign matter including preparing the surface even and sand paper
smooth, cost of materials, labour complete as per specifications and as per
directions of Engineer-in-charge. | Sqm | 120.75 | 120.75 | 51.0 | False | None | None | False | None | False | 6158.25 | 0 | | 2879188 | 94105 | None | 13.2.1 | Providing and fixing brass bib cock of approved quality : | Each | 300.3 | 300.3 | 5.0 | False | None | None | False | None | False | 1501.5 | 0 | | 2879189 | 94105 | None | 1.6.1 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required
to complete the work. | Cum | 508.2 | 508.2 | 55.0 | False | None | None | False | None | False | 27951.0 | 0 | | 2879190 | 94105 | None | 9.1.1 | Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for
testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0 HDPE Grade PE80-PN6.0, 63mm dia | Mtr | 198.45 | 198.45 | 55.0 | False | None | None | False | None | False | 10914.75 | 0 |
| | 1709347272000 | 0 | None | None | Buildings | Development and Repairs of Electrification at GHPS School at RMSA at Baragur Village of Karatagi Taluka | 43321.0 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 2879191 | 94106 | None | 1.1.1 | Supplying and fixing sheet Metal box made out of 18 SWG sheet
metal with necessary holes for cable/conduit entry as required with one
coat of primer of approved make etc 75 x 75 x 65 mm | No | 106.0 | 106.0 | 5.0 | False | None | None | False | None | False | 530.0 | 0 | | 2879192 | 94106 | None | 2.2.1 | Supplying and wiring adopting loop system in existing PVC Conduit
/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral)
& 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated
copper wire (confirming to IS-694: and latest amendments) without
control switch shall be fixed on the existing plastic sheet/ gang box,
the other end of the wires shall be terminated with sufficient loose
length in a wood/PVC round block. complete for each outlet.
Short point upto 3Mtr from tapping point to out let via switch box | No | 285.0 | 285.0 | 5.0 | False | None | None | False | None | False | 1425.0 | 0 | | 2879193 | 94106 | None | 2.2.1 | Medium point above 3Mtr upto 6Mtr from tapping point to out let via
switch box | No | 394.0 | 394.0 | 5.0 | False | None | None | False | None | False | 1970.0 | 0 | | 2879194 | 94106 | None | 2.2.2 | Long point above 6Mtr upto 10Mtr from tapping point to out let via
switch box | No | 555.0 | 555.0 | 5.0 | False | None | None | False | None | False | 2775.0 | 0 | | 2879195 | 94106 | None | 3.8 | Supplying 4mm thick plastic sheet with necessary nitches for
fixing switches, regulators etc, and fixing on existing wooden or
metal box using N.F. screws | Sqm | 0.41 | 0.41 | 1500.0 | False | None | None | False | None | False | 615.0 | 0 | | 2879196 | 94106 | None | 3.1.2 | Supplying 6A flush type socket and 6 A flush type SP switch either
surface/flush mounting in existing gang box or in 4mm thick plastic
sheet and fixing over a flush mounted wooden box and wiring using
necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 Way | Each | 147.0 | 147.0 | 12.0 | False | None | None | False | None | False | 1764.0 | 0 | | 2879197 | 94106 | None | 6.3.1 | Supplying capacitor type ceiling fan complete with down rod blades,
shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase
AC supply conforming to ISS-374- 1979 and with double ball bearing
system 48" Sweep (1200 mm) Regular mode | No | 1900.0 | 1900.0 | 6.0 | False | None | None | False | None | False | 11400.0 | 0 | | 2879198 | 94106 | None | 11.13 | Supplying and fixing of slim patty fitting, made out of CRCA Sheet
metal body with locking type holder completely wired. Excluding
Ballast & Fluorescent Tube. | No | 361.0 | 361.0 | 6.0 | False | None | None | False | None | False | 2166.0 | 0 | | 2879199 | 94106 | None | 13.1.1 | Supplying and Fixing of.mm dia class A GI pipe bracket upto 2
ms long bent at suitable angle and fixing to this bracket street light
fitting of all capacities to GI or GI or rail or RCC pole / wall using
suitable clamps, bolts, and nuts and wiring using suitable capacity
wires. Using 25mm dia G.I.Pipe | No | 978.0 | 978.0 | 1.0 | False | None | None | False | None | False | 978.0 | 0 | | 2879200 | 94106 | None | 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 1.5 mm | m | 26.0 | 26.0 | 40.0 | False | None | None | False | None | False | 1040.0 | 0 | | 2879201 | 94106 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010
2.5 mm2 | m | 42.0 | 42.0 | 40.0 | False | None | None | False | None | False | 1680.0 | 0 | | 2879202 | 94106 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 4 mm2 | m | 63.0 | 63.0 | 40.0 | False | None | None | False | None | False | 2520.0 | 0 | | 2879203 | 94106 | None | 1.1.1 | SupplyingheavygaugePVCconduitpipe.dia.mmthickconfirmingtoIS2509withsuitablesizebends,junctionboxes,adhesivepasteetc,andfixingusinginvertedwoodplugsincaseofRCCceilingandRCCwall/stonestructureorrawlplugsincaseofbrickwallsandcementplasteringthedamagedportionusingheavygauge saddles at an interval of 700mm using NF screws. | Mtr | 69.0 | 69.0 | 40.0 | False | None | None | False | None | False | 2760.0 | 0 | | 2879204 | 94106 | None | Page No. 23 | Pre - Paid Energy Meter Single Phase, 5-30 Amps, 1.0 Accuracy Class with Key Pad Technology consumer interface unit along with pillfer proof box | No | 7170.0 | 7170.0 | 1.0 | False | None | None | False | None | False | 7170.0 | 0 | | 2879205 | 94106 | None | 12.60.1 | Supplying&FixingChemicalearthlingforgrounding.Conduits,ICcut-outs&otherequipmentsbackfillcompoundwhichisnon-corrosive,thermallyconductive,potentialtopermissiblelimits,superiorFaultconductioncapacity,nontoxic,weatherresistance&capable of achieving ohmic value less than one ohmUsing 4ft. Copper bonded rod with backfill compound | No | 4528.0 | 4528.0 | 1.0 | False | None | None | False | None | False | 4528.0 | 0 |
| | 1709347272000 | 0 | None | None | Buildings | Repairs of Building and Repairs of Electrification at School at Heror Village | 180572.25 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 2879206 | 94107 | None | 15.2 | Providing and Applying PU based Elastomeric Liquid Applied PU
Waterproofing Membrane single component, cold applied, water based
acrylic PU dispersion with highly elastic and UV resistant water proofing
treatment to the Existing Roof surface/Chajjas/Sunken portion of
WC:Bathroom applied @ 1.2 l/per m2, having tensile strength greater than
1.5N/mm2, elongation greater than 300% with solid content not less than
60% in 2 coats including surface preparation, priming the surface with
water based acrylic primer @0.1 l/m2, and spreading 60 gsm geotextile
between two top coats completely as per specification. The finished cost
to include surface preparation, making coving at Junction, Bore Packing,
treatment of construction joints completely as per specification. | Sqm | 773.85 | 773.85 | 64.0 | False | None | None | False | None | False | 49526.4 | 0 | | 2879207 | 94107 | None | 8.72.1 | Finishing walls with water proofing cement paint of required shade
:Old work (one coats applied @ 2.20 kg/10 m²) over priming
coat of primer applied @ 0.80 litrs/10 m² complete including
cost of Priming coat including preparing the surface after thoroughly
cleaning the surface to remove all dirt, dust and foreign matter, cost of
materials, labour complete as per specifications and as per directions
of Engineer-in-charge | Sqm | 91.35 | 91.35 | 240.64 | False | None | None | False | None | False | 21982.464 | 0 | | 2879208 | 94107 | None | 19.22 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction
of Engineer-in-charge | Sqm | 50.4 | 50.4 | 46.4 | False | None | None | False | None | False | 2338.56 | 0 | | 2879209 | 94107 | None | 2.1.1 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required t complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M7.5) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 4.64 | False | None | None | False | None | False | 27595.008 | 0 | | 2879210 | 94107 | None | 9.12.2 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grou ting the joints with white cement and matching pigments etc., complete. (Size of Tile 600x600 mm)
| Sqm | 1202.25 | 1202.25 | 51.92 | False | None | None | False | None | False | 62420.82 | 0 | | 2879211 | 94107 | None | 1.1.1 | SupplyingheavygaugePVCconduitpipe.dia.mmthickconfirmingtoIS2509withsuitablesizebends,junctionboxes,adhesivepasteetc,andfixingusinginvertedwoodplugsincaseofRCCceilingandRCCwall/stonestructureorrawlplugsincaseofbrickwallsandcementplasteringthedamagedportionusingheavygauge saddles at an interval of 700mm using NF screws. | Mtr | 69.0 | 69.0 | 20.0 | False | None | None | False | None | False | 1380.0 | 0 | | 2879212 | 94107 | None | 1.1.1 | Supplying and fixing sheet Metal box made out of 18 SWG sheet
metal with necessary holes for cable/conduit entry as required with one
coat of primer of approved make etc 75 x 75 x 65 mm | No | 106.0 | 106.0 | 4.0 | False | None | None | False | None | False | 424.0 | 0 | | 2879213 | 94107 | None | 2.2.1 | Supplying and wiring adopting loop system in existing PVC Conduit
/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral)
& 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated
copper wire (confirming to IS-694: and latest amendments) without
control switch shall be fixed on the existing plastic sheet/ gang box,
the other end of the wires shall be terminated with sufficient loose
length in a wood/PVC round block. complete for each outlet.
Short point upto 3Mtr from tapping point to out let via switch box | No | 285.0 | 285.0 | 2.0 | False | None | None | False | None | False | 570.0 | 0 | | 2879214 | 94107 | None | 2.2.1 | Medium point above 3Mtr upto 6Mtr from tapping point to out let via
switch box | No | 394.0 | 394.0 | 2.0 | False | None | None | False | None | False | 788.0 | 0 | | 2879215 | 94107 | None | 2.2.2 | Long point above 6Mtr upto 10Mtr from tapping point to out let via
switch box | No | 555.0 | 555.0 | 2.0 | False | None | None | False | None | False | 1110.0 | 0 | | 2879216 | 94107 | None | 3.8 | Supplying 4mm thick plastic sheet with necessary nitches for
fixing switches, regulators etc, and fixing on existing wooden or
metal box using N.F. screws | Sqm | 0.41 | 0.41 | 600.0 | False | None | None | False | None | False | 246.0 | 0 | | 2879217 | 94107 | None | 3.1.2 | Supplying 6A flush type socket and 6 A flush type SP switch either
surface/flush mounting in existing gang box or in 4mm thick plastic
sheet and fixing over a flush mounted wooden box and wiring using
necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 Way | Each | 147.0 | 147.0 | 6.0 | False | None | None | False | None | False | 882.0 | 0 | | 2879218 | 94107 | None | 6.3.1 | Supplying capacitor type ceiling fan complete with down rod blades,
shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase
AC supply conforming to ISS-374- 1979 and with double ball bearing
system 48" Sweep (1200 mm) Regular mode | No | 1900.0 | 1900.0 | 2.0 | False | None | None | False | None | False | 3800.0 | 0 | | 2879219 | 94107 | None | 11.13 | Supplying and fixing of slim patty fitting, made out of CRCA Sheet
metal body with locking type holder completely wired. Excluding
Ballast & Fluorescent Tube. | No | 361.0 | 361.0 | 1.0 | False | None | None | False | None | False | 361.0 | 0 | | 2879220 | 94107 | None | 12.60.1 | Supplying&FixingChemicalearthlingforgrounding.Conduits,ICcut-outs&otherequipmentsbackfillcompoundwhichisnon-corrosive,thermallyconductive,potentialtopermissiblelimits,superiorFaultconductioncapacity,nontoxic,weatherresistance&capable of achieving ohmic value less than one ohmUsing 4ft. Copper bonded rod with backfill compound | No / m | 4528.0 | 4528.0 | 1.0 | False | None | None | False | None | False | 4528.0 | 0 | | 2879221 | 94107 | None | 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 1.5 mm | m | 26.0 | 26.0 | 20.0 | False | None | None | False | None | False | 520.0 | 0 | | 2879222 | 94107 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010
2.5 mm2 | m | 42.0 | 42.0 | 20.0 | False | None | None | False | None | False | 840.0 | 0 | | 2879223 | 94107 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 4 mm2 | m | 63.0 | 63.0 | 20.0 | False | None | None | False | None | False | 1260.0 | 0 |
| | 1709347272000 | 0 | None | None | Buildings | Repairs of Electrification at GHPS School at Siddapur Village | 12185.0 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 2879224 | 94108 | None | 3.1.2 | Supplying 6A flush type socket and 6 A flush type SP switch either
surface/flush mounting in existing gang box or in 4mm thick plastic
sheet and fixing over a flush mounted wooden box and wiring using
necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 Way | Each | 147.0 | 147.0 | 8.0 | False | None | None | False | None | False | 1176.0 | 0 | | 2879225 | 94108 | None | 6.3.1 | Supplying capacitor type ceiling fan complete with down rod blades,
shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase
AC supply conforming to ISS-374- 1979 and with double ball bearing
system 48" Sweep (1200 mm) Regular mode | No | 1900.0 | 1900.0 | 4.0 | False | None | None | False | None | False | 7600.0 | 0 | | 2879226 | 94108 | None | 11.13 | Supplying and fixing of slim patty fitting, made out of CRCA Sheet
metal body with locking type holder completely wired. Excluding
Ballast & Fluorescent Tube. | No | 361.0 | 361.0 | 4.0 | False | None | None | False | None | False | 1444.0 | 0 | | 2879227 | 94108 | None | 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 1.5 mm | m | 26.0 | 26.0 | 15.0 | False | None | None | False | None | False | 390.0 | 0 | | 2879228 | 94108 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010
2.5 mm2 | m | 42.0 | 42.0 | 15.0 | False | None | None | False | None | False | 630.0 | 0 | | 2879229 | 94108 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 4 mm2 | m | 63.0 | 63.0 | 15.0 | False | None | None | False | None | False | 945.0 | 0 |
| | 1709347272000 | 0 | None | None | Buildings | Repairs of Building and Electrification at GHPS School at Chikkajanatakal Village | 349678.71 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 2879230 | 94109 | None | 1.1.1 | SupplyingheavygaugePVCconduitpipe.dia.mmthickconfirmingtoIS2509withsuitablesizebends,junctionboxes,adhesivepasteetc,andfixingusinginvertedwoodplugsincaseofRCCceilingandRCCwall/stonestructureorrawlplugsincaseofbrickwallsandcementplasteringthedamagedportionusingheavygauge saddles at an interval of 700mm using NF screws. | No | 69.0 | 69.0 | 25.0 | False | None | None | False | None | False | 1725.0 | 0 | | 2879231 | 94109 | None | 1.1.1 | Supplying and fixing sheet Metal box made out of 18 SWG sheet
metal with necessary holes for cable/conduit entry as required with one
coat of primer of approved make etc 75 x 75 x 65 mm | No | 106.0 | 106.0 | 4.0 | False | None | None | False | None | False | 424.0 | 0 | | 2879232 | 94109 | None | 2.2.1 | Supplying and wiring adopting loop system in existing PVC Conduit
/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral)
& 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated
copper wire (confirming to IS-694: and latest amendments) without
control switch shall be fixed on the existing plastic sheet/ gang box,
the other end of the wires shall be terminated with sufficient loose
length in a wood/PVC round block. complete for each outlet.
Short point upto 3Mtr from tapping point to out let via switch box | No | 285.0 | 285.0 | 2.0 | False | None | None | False | None | False | 570.0 | 0 | | 2879233 | 94109 | None | 2.2.1 | Medium point above 3Mtr upto 6Mtr from tapping point to out let via
switch box | No | 394.0 | 394.0 | 2.0 | False | None | None | False | None | False | 788.0 | 0 | | 2879234 | 94109 | None | 2.2.2 | Long point above 6Mtr upto 10Mtr from tapping point to out let via
switch box | No | 555.0 | 555.0 | 2.0 | False | None | None | False | None | False | 1110.0 | 0 | | 2879235 | 94109 | None | 3.8 | Supplying 4mm thick plastic sheet with necessary nitches for
fixing switches, regulators etc, and fixing on existing wooden or
metal box using N.F. screws | Sqm | 0.41 | 0.41 | 600.0 | False | None | None | False | None | False | 246.0 | 0 | | 2879236 | 94109 | None | 3.1.2 | Supplying 6A flush type socket and 6 A flush type SP switch either
surface/flush mounting in existing gang box or in 4mm thick plastic
sheet and fixing over a flush mounted wooden box and wiring using
necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 Way | Each | 147.0 | 147.0 | 4.0 | False | None | None | False | None | False | 588.0 | 0 | | 2879237 | 94109 | None | 6.3.1 | Supplying capacitor type ceiling fan complete with down rod blades,
shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase
AC supply conforming to ISS-374- 1979 and with double ball bearing
system 48" Sweep (1200 mm) Regular mode | No | 1900.0 | 1900.0 | 2.0 | False | None | None | False | None | False | 3800.0 | 0 | | 2879238 | 94109 | None | 11.13 | Supplying and fixing of slim patty fitting, made out of CRCA Sheet
metal body with locking type holder completely wired. Excluding
Ballast & Fluorescent Tube. | No | 361.0 | 361.0 | 2.0 | False | None | None | False | None | False | 722.0 | 0 | | 2879239 | 94109 | None | 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 1.5 mm | m | 26.0 | 26.0 | 13.0 | False | None | None | False | None | False | 338.0 | 0 | | 2879240 | 94109 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010
2.5 mm2 | m | 42.0 | 42.0 | 13.0 | False | None | None | False | None | False | 546.0 | 0 | | 2879241 | 94109 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 4 mm2 | m | 63.0 | 63.0 | 13.0 | False | None | None | False | None | False | 819.0 | 0 | | 2879242 | 94109 | None | 12.60.1 | Supplying&FixingChemicalearthlingforgrounding.Conduits,ICcut-outs&otherequipmentsbackfillcompoundwhichisnon-corrosive,thermallyconductive,potentialtopermissiblelimits,superiorFaultconductioncapacity,nontoxic,weatherresistance&capable of achieving ohmic value less than one ohmUsing 4ft. Copper bonded rod with backfill compound | No | 4528.0 | 4528.0 | 1.0 | False | None | None | False | None | False | 4528.0 | 0 | | 2879243 | 94109 | None | 15.23 | Providing and Applying PU based Elastomeric Liquid Applied PU
Waterproofing Membrane single component, cold applied, water based
acrylic PU dispersion with highly elastic and UV resistant water proofing
treatment to the Existing Roof surface/Chajjas/Sunken portion of
WC:Bathroom applied @ 1.2 l/per m2, having tensile strength greater than
1.5N/mm2, elongation greater than 300% with solid content not less than
60% in 2 coats including surface preparation, priming the surface with
water based acrylic primer @0.1 l/m2, and spreading 60 gsm geotextile
between two top coats completely as per specification. The finished cost
to include surface preparation, making coving at Junction, Bore Packing,
treatment of construction joints completely as per specification. | Sqm | 773.85 | 773.85 | 135.0 | False | None | None | False | None | False | 104469.75 | 0 | | 2879244 | 94109 | None | 8.72.1 | Finishing walls with water proofing cement paint of required shade
:Old work (one coats applied @ 2.20 kg/10 m²) over priming
coat of primer applied @ 0.80 litrs/10 m² complete including
cost of Priming coat including preparing the surface after thoroughly
cleaning the surface to remove all dirt, dust and foreign matter, cost of
materials, labour complete as per specifications and as per directions
of Engineer-in-charge | Sqm | 91.35 | 91.35 | 442.2 | False | None | None | False | None | False | 40394.97 | 0 | | 2879245 | 94109 | None | 19.22 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction
of Engineer-in-charge | Cum | 50.4 | 50.4 | 98.4 | False | None | None | False | None | False | 4959.36 | 0 | | 2879246 | 94109 | None | 2.1.1 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required t complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M7.5) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 9.84 | False | None | None | False | None | False | 58520.448 | 0 | | 2879247 | 94109 | None | 9.12.2 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grou ting the joints with white cement and matching pigments etc., complete. (Size of Tile 600x600 mm) | Sqm | 1202.25 | 1202.25 | 104.08 | False | None | None | False | None | False | 125130.18 | 0 |
| | 1709347272000 | 0 | None | None | Buildings | Repairs of Building and Electrification at School at Hulihyder Village | 180804.56 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 2879248 | 94110 | None | 19.22 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction
of Engineer-in-charge | Cum | 50.4 | 50.4 | 96.0 | False | None | None | False | None | False | 4838.4 | 0 | | 2879249 | 94110 | None | 2.1.1 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required t complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M7.5) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 4.8 | False | None | None | False | None | False | 28546.56 | 0 | | 2879250 | 94110 | None | 9.12.2 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grou ting the joints with white cement and matching pigments etc., complete. (Size of Tile 600x600 mm)
| Sqm | 1202.25 | 1202.25 | 101.6 | False | None | None | False | None | False | 122148.6 | 0 | | 2879251 | 94110 | None | 1.1.1 | Supplying and fixing sheet Metal box made out of 18 SWG sheet
metal with necessary holes for cable/conduit entry as required with one
coat of primer of approved make etc 75 x 75 x 65 mm | No | 106.0 | 106.0 | 4.0 | False | None | None | False | None | False | 424.0 | 0 | | 2879252 | 94110 | None | 2.2.1 | Supplying and wiring adopting loop system in existing PVC Conduit
/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral)
& 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated
copper wire (confirming to IS-694: and latest amendments) without
control switch shall be fixed on the existing plastic sheet/ gang box,
the other end of the wires shall be terminated with sufficient loose
length in a wood/PVC round block. complete for each outlet.
Short point upto 3Mtr from tapping point to out let via switch box | No | 285.0 | 285.0 | 4.0 | False | None | None | False | None | False | 1140.0 | 0 | | 2879253 | 94110 | None | 2.2.1 | Medium point above 3Mtr upto 6Mtr from tapping point to out let via
switch box | No | 394.0 | 394.0 | 4.0 | False | None | None | False | None | False | 1576.0 | 0 | | 2879254 | 94110 | None | 2.2.2 | Long point above 6Mtr upto 10Mtr from tapping point to out let via
switch box | No | 555.0 | 555.0 | 4.0 | False | None | None | False | None | False | 2220.0 | 0 | | 2879255 | 94110 | None | 3.8 | Supplying 4mm thick plastic sheet with necessary nitches for
fixing switches, regulators etc, and fixing on existing wooden or
metal box using N.F. screws | Sqm | 0.41 | 0.41 | 800.0 | False | None | None | False | None | False | 328.0 | 0 | | 2879256 | 94110 | None | 3.1.2 | Supplying 6A flush type socket and 6 A flush type SP switch either
surface/flush mounting in existing gang box or in 4mm thick plastic
sheet and fixing over a flush mounted wooden box and wiring using
necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 Way | Each | 147.0 | 147.0 | 8.0 | False | None | None | False | None | False | 1176.0 | 0 | | 2879257 | 94110 | None | 6.3.1 | Supplying capacitor type ceiling fan complete with down rod blades,
shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase
AC supply conforming to ISS-374- 1979 and with double ball bearing
system 48" Sweep (1200 mm) Regular mode | No | 1900.0 | 1900.0 | 6.0 | False | None | None | False | None | False | 11400.0 | 0 | | 2879258 | 94110 | None | 11.13 | Supplying and fixing of slim patty fitting, made out of CRCA Sheet
metal body with locking type holder completely wired. Excluding
Ballast & Fluorescent Tube. | No | 361.0 | 361.0 | 4.0 | False | None | None | False | None | False | 1444.0 | 0 | | 2879259 | 94110 | None | 13.1.1 | Supplying and Fixing of.mm dia class A GI pipe bracket upto 2
ms long bent at suitable angle and fixing to this bracket street light
fitting of all capacities to GI or GI or rail or RCC pole / wall using
suitable clamps, bolts, and nuts and wiring using suitable capacity
wires. Using 25mm dia G.I.Pipe | No | 978.0 | 978.0 | 1.0 | False | None | None | False | None | False | 978.0 | 0 | | 2879260 | 94110 | None | 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 1.5 mm | m | 26.0 | 26.0 | 35.0 | False | None | None | False | None | False | 910.0 | 0 | | 2879261 | 94110 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010
2.5 mm2 | m | 42.0 | 42.0 | 35.0 | False | None | None | False | None | False | 1470.0 | 0 | | 2879262 | 94110 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 4 mm2 | m | 63.0 | 63.0 | 35.0 | False | None | None | False | None | False | 2205.0 | 0 |
| | 1709347272000 | 0 | None | None | Buildings | Repairs of School Building and Repairs of Electrification at Govt School at Kanakagiri Village | 180804.56 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 2879263 | 94111 | None | 19.22 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction
of Engineer-in-charge | Cum | 50.4 | 50.4 | 96.0 | False | None | None | False | None | False | 4838.4 | 0 | | 2879264 | 94111 | None | 2.1.1 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required t complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M7.5) Using 40 mm nominal size graded crushed coarse aggregates
| Cum | 5947.2 | 5947.2 | 4.8 | False | None | None | False | None | False | 28546.56 | 0 | | 2879265 | 94111 | None | 9.12.2 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grou ting the joints with white cement and matching pigments etc., complete. (Size of Tile 600x600 mm) | Sqm | 1202.25 | 1202.25 | 101.6 | False | None | None | False | None | False | 122148.6 | 0 | | 2879266 | 94111 | None | 1.1.1 | Supplying and fixing sheet Metal box made out of 18 SWG sheet
metal with necessary holes for cable/conduit entry as required with one
coat of primer of approved make etc 75 x 75 x 65 mm | No | 106.0 | 106.0 | 4.0 | False | None | None | False | None | False | 424.0 | 0 | | 2879267 | 94111 | None | 2.2.1 | Supplying and wiring adopting loop system in existing PVC Conduit
/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral)
& 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated
copper wire (confirming to IS-694: and latest amendments) without
control switch shall be fixed on the existing plastic sheet/ gang box,
the other end of the wires shall be terminated with sufficient loose
length in a wood/PVC round block. complete for each outlet.
Short point upto 3Mtr from tapping point to out let via switch box | No | 285.0 | 285.0 | 4.0 | False | None | None | False | None | False | 1140.0 | 0 | | 2879268 | 94111 | None | 2.2.1 | Medium point above 3Mtr upto 6Mtr from tapping point to out let via
switch box | No | 394.0 | 394.0 | 4.0 | False | None | None | False | None | False | 1576.0 | 0 | | 2879269 | 94111 | None | 2.2.2 | Long point above 6Mtr upto 10Mtr from tapping point to out let via
switch box | No | 555.0 | 555.0 | 4.0 | False | None | None | False | None | False | 2220.0 | 0 | | 2879270 | 94111 | None | 3.8 | Supplying 4mm thick plastic sheet with necessary nitches for
fixing switches, regulators etc, and fixing on existing wooden or
metal box using N.F. screws | Sqm | 0.41 | 0.41 | 800.0 | False | None | None | False | None | False | 328.0 | 0 | | 2879271 | 94111 | None | 3.1.2 | Supplying 6A flush type socket and 6 A flush type SP switch either
surface/flush mounting in existing gang box or in 4mm thick plastic
sheet and fixing over a flush mounted wooden box and wiring using
necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 Way | Each | 147.0 | 147.0 | 8.0 | False | None | None | False | None | False | 1176.0 | 0 | | 2879272 | 94111 | None | 6.3.1 | Supplying capacitor type ceiling fan complete with down rod blades,
shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase
AC supply conforming to ISS-374- 1979 and with double ball bearing
system 48" Sweep (1200 mm) Regular mode | No | 1900.0 | 1900.0 | 6.0 | False | None | None | False | None | False | 11400.0 | 0 | | 2879273 | 94111 | None | 11.13 | Supplying and fixing of slim patty fitting, made out of CRCA Sheet
metal body with locking type holder completely wired. Excluding
Ballast & Fluorescent Tube. | No | 361.0 | 361.0 | 4.0 | False | None | None | False | None | False | 1444.0 | 0 | | 2879274 | 94111 | None | 13.1.1 | Supplying and Fixing of.mm dia class A GI pipe bracket upto 2
ms long bent at suitable angle and fixing to this bracket street light
fitting of all capacities to GI or GI or rail or RCC pole / wall using
suitable clamps, bolts, and nuts and wiring using suitable capacity
wires. Using 25mm dia G.I.Pipe | No | 978.0 | 978.0 | 1.0 | False | None | None | False | None | False | 978.0 | 0 | | 2879275 | 94111 | None | 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 1.5 mm | m | 26.0 | 26.0 | 35.0 | False | None | None | False | None | False | 910.0 | 0 | | 2879276 | 94111 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010
2.5 mm2 | m | 42.0 | 42.0 | 35.0 | False | None | None | False | None | False | 1470.0 | 0 | | 2879277 | 94111 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 4 mm2 | m | 63.0 | 63.0 | 35.0 | False | None | None | False | None | False | 2205.0 | 0 |
| | 1709347272000 | 0 | None | None | Buildings | Const of Water Tank Repairs of School Building and Elcetrification at Govt School at Navali Village | 348657.59 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 2879278 | 94112 | None | 1.4 | Earth work excavation by manual means for drains, canals, waste weir, draft,
approach channels, key trenches, foundation of Buildings & bridges and such
simillar works in all kinds of soils, as per drawing and technical specifications,
including setting out, shoring, strutting, barricading, caution lights, removal
of stumps and other deleterious matter, excavated surface leveled and sides
neatly dressed disposing off the excavated stuff or sorting & stacking the
selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of
labour, tools & other appurtenaces required to complete the work. | Cum | 254.1 | 254.1 | 6.75 | False | None | None | False | None | False | 1715.175 | 0 | | 2879279 | 94112 | None | 2.1.1 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in
layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates work as per technical specifications | Cum | 5947.2 | 5947.2 | 1.4 | False | None | None | False | None | False | 8326.08 | 0 | | 2879280 | 94112 | None | 5.2 | Providing Coursed rubble masonry (first sort) with hard stone in foundation
and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6948.9 | 6948.9 | 1.5 | False | None | None | False | None | False | 10423.35 | 0 | | 2879281 | 94112 | None | 5.3 | Providing Coursed rubble masonry (second sort) with hard stone in
foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand | Cum | 6515.25 | 6515.25 | 1.2 | False | None | None | False | None | False | 7818.3 | 0 | | 2879282 | 94112 | None | 5.4 | Providing Size Stone masonry with hard stone in foundation & plinth with
Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6708.45 | 6708.45 | 2.7 | False | None | None | False | None | False | 18112.815 | 0 | | 2879283 | 94112 | None | 1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of
foundations and other similar works etc. in layers not exceeding 20cm in depth,
consolidating each deposited layer by ramming and watering, lead up to 50 m
and lift upto 1.5 m. | Cum | 279.3 | 279.3 | 3.6 | False | None | None | False | None | False | 1005.48 | 0 | | 2879284 | 94112 | None | 2.2.1 | Providing and laying in position Cement Concrete for all Foundation works.
The granite/trap/basalt crushed graded coarse aggregates and fine aggregates
as per relevant IS Codes machine mixed with super plasticizers laid in finished
layers, well compacted using needle vibrators, including all lead & lifts, cost
of all materials, quality confirming to the requirements of relevant IS codes,
labour, Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6601.35 | 6601.35 | 1.1 | False | None | None | False | None | False | 7261.485 | 0 | | 2879285 | 94112 | None | 2.5.1 | Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cum | Sqm | 3960.81 | 3960.81 | 0.35 | False | None | None | False | None | False | 1386.2835 | 0 | | 2879286 | 94112 | None | 2.5.1 | Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cum | Sqm | 3300.68 | 3300.68 | 0.75 | False | None | None | False | None | False | 2475.51 | 0 | | 2879287 | 94112 | None | 2.11 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement
including cost of all materials, machinery, labour, cleaning, straightening,
cutting, bending, hooking, laping/welding joints, tying with binding wire / soft
annealed steel wire and other ancilary operations complete as per drawing and
technical specification.
| Tonne | 93929.85 | 93929.85 | 0.1 | False | None | None | False | None | False | 9392.985 | 0 | | 2879288 | 94112 | None | 6.7 | Providing Brick work with common burnt clay Non Modular bricks of
class designation 3.5 in superstructure above plinth level in all shapes and
sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of
all materials, labour, scaffolding and usage charges of machinery & other
incidental charges complete as per the direction of engineer incharge of
work. | Cum | 8621.55 | 8621.55 | 4.14 | False | None | None | False | None | False | 35693.217 | 0 | | 2879289 | 94112 | None | 8.6.1 | Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3
coarse sand) finished with a floating coat of neat cement to brick masonry
including rounding off corners wherever required smooth rendering,
providing and removing scaffolding, including cost of materials, labour,
curing complete as per specifications and as per directions of Engineerin-charge. | Sqm | 339.15 | 339.15 | 51.0 | False | None | None | False | None | False | 17296.65 | 0 | | 2879290 | 94112 | None | 8.40 | Painting with synthetic enamel paint of approved brand and
manufacture to give an even shade :Two coats on new work after
thoroughly brooming the surface to remove all dirt, dust, mortar drops
and foreign matter including preparing the surface even and sand paper
smooth, cost of materials, labour complete as per specifications and as per
directions of Engineer-in-charge. | Sqm | 120.75 | 120.75 | 51.0 | False | None | None | False | None | False | 6158.25 | 0 | | 2879291 | 94112 | None | 13.2.1 | Providing and fixing brass bib cock of approved quality : | Each | 300.3 | 300.3 | 5.0 | False | None | None | False | None | False | 1501.5 | 0 | | 2879292 | 94112 | None | 1.6.1 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required
to complete the work. | No | 508.2 | 508.2 | 55.0 | False | None | None | False | None | False | 27951.0 | 0 | | 2879293 | 94112 | None | 9.1.1 | Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for
testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0 HDPE Grade PE80-PN6.0, 63mm dia | Mtr | 198.45 | 198.45 | 55.0 | False | None | None | False | None | False | 10914.75 | 0 | | 2879294 | 94112 | None | 8.33.1 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign atter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 165.9 | 165.9 | 72.0 | False | None | None | False | None | False | 11944.8 | 0 | | 2879295 | 94112 | None | 19.22 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction
of Engineer-in-charge | Cum | 50.4 | 50.4 | 81.2 | False | None | None | False | None | False | 4092.48 | 0 | | 2879296 | 94112 | None | 2.1.1 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required t complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M7.5) Using 40 mm nominal size graded crushed coarse aggregates
| Cum | 5947.2 | 5947.2 | 8.12 | False | None | None | False | None | False | 48291.264 | 0 | | 2879297 | 94112 | None | 9.12.2 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grou ting the joints with white cement and matching pigments etc., complete. (Size of Tile 600x600 mm) | Sqm | 1202.25 | 1202.25 | 86.32 | False | None | None | False | None | False | 103778.22 | 0 | | 2879298 | 94112 | None | 1.1.1 | SupplyingheavygaugePVCconduitpipe.dia.mmthickconfirmingtoIS2509withsuitablesizebends,junctionboxes,adhesivepasteetc,andfixingusinginvertedwoodplugsincaseofRCCceilingandRCCwall/stonestructureorrawlplugsincaseofbrickwallsandcementplasteringthedamagedportionusingheavygauge saddles at an interval of 700mm using NF screws. | Mtr | 69.0 | 69.0 | 30.0 | False | None | None | False | None | False | 2070.0 | 0 | | 2879299 | 94112 | None | 1.1.1 | Supplying and fixing sheet Metal box made out of 18 SWG sheet
metal with necessary holes for cable/conduit entry as required with one
coat of primer of approved make etc 75 x 75 x 65 mm | No | 106.0 | 106.0 | 4.0 | False | None | None | False | None | False | 424.0 | 0 | | 2879300 | 94112 | None | 2.2.1 | Supplying and wiring adopting loop system in existing PVC Conduit
/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral)
& 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated
copper wire (confirming to IS-694: and latest amendments) without
control switch shall be fixed on the existing plastic sheet/ gang box,
the other end of the wires shall be terminated with sufficient loose
length in a wood/PVC round block. complete for each outlet.
Short point upto 3Mtr from tapping point to out let via switch box | No | 285.0 | 285.0 | 2.0 | False | None | None | False | None | False | 570.0 | 0 | | 2879301 | 94112 | None | 2.2.1 | Medium point above 3Mtr upto 6Mtr from tapping point to out let via
switch box | No | 394.0 | 394.0 | 2.0 | False | None | None | False | None | False | 788.0 | 0 | | 2879302 | 94112 | None | 2.2.2 | Long point above 6Mtr upto 10Mtr from tapping point to out let via
switch box | No | 555.0 | 555.0 | 2.0 | False | None | None | False | None | False | 1110.0 | 0 | | 2879303 | 94112 | None | 3.8 | Supplying 4mm thick plastic sheet with necessary nitches for
fixing switches, regulators etc, and fixing on existing wooden or
metal box using N.F. screws | Sqm | 0.41 | 0.41 | 1000.0 | False | None | None | False | None | False | 410.0 | 0 | | 2879304 | 94112 | None | 3.1.2 | Supplying 6A flush type socket and 6 A flush type SP switch either
surface/flush mounting in existing gang box or in 4mm thick plastic
sheet and fixing over a flush mounted wooden box and wiring using
necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 Way | Each | 147.0 | 147.0 | 5.0 | False | None | None | False | None | False | 735.0 | 0 | | 2879305 | 94112 | None | 6.3.1 | Supplying capacitor type ceiling fan complete with down rod blades,
shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase
AC supply conforming to ISS-374- 1979 and with double ball bearing
system 48" Sweep (1200 mm) Regular mode | No | 1900.0 | 1900.0 | 2.0 | False | None | None | False | None | False | 3800.0 | 0 | | 2879306 | 94112 | None | 11.13 | Supplying and fixing of slim patty fitting, made out of CRCA Sheet
metal body with locking type holder completely wired. Excluding
Ballast & Fluorescent Tube. | No | 361.0 | 361.0 | 2.0 | False | None | None | False | None | False | 722.0 | 0 | | 2879307 | 94112 | None | 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 1.5 mm | m | 26.0 | 26.0 | 19.0 | False | None | None | False | None | False | 494.0 | 0 | | 2879308 | 94112 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010
2.5 mm2 | m | 42.0 | 42.0 | 19.0 | False | None | None | False | None | False | 798.0 | 0 | | 2879309 | 94112 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 4 mm2 | m | 63.0 | 63.0 | 19.0 | False | None | None | False | None | False | 1197.0 | 0 |
| | 1709347272000 | 0 | None | None | Buildings | Repairs of Electrification at GHPS at RMSA at Marali Village | 42080.0 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 2879310 | 94113 | None | 1.1.1 | SupplyingheavygaugePVCconduitpipe.dia.mmthickconfirmingtoIS2509withsuitablesizebends,junctionboxes,adhesivepasteetc,andfixingusinginvertedwoodplugsincaseofRCCceilingandRCCwall/stonestructureorrawlplugsincaseofbrickwallsandcementplasteringthedamagedportionusingheavygauge saddles at an interval of 700mm using NF screws. | Mtr | 69.0 | 69.0 | 30.0 | False | None | None | False | None | False | 2070.0 | 0 | | 2879311 | 94113 | None | 1.1.1 | Supplying and fixing sheet Metal box made out of 18 SWG sheet
metal with necessary holes for cable/conduit entry as required with one
coat of primer of approved make etc 75 x 75 x 65 mm | No | 106.0 | 106.0 | 4.0 | False | None | None | False | None | False | 424.0 | 0 | | 2879312 | 94113 | None | 2.2.1 | Supplying and wiring adopting loop system in existing PVC Conduit
/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral)
& 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated
copper wire (confirming to IS-694: and latest amendments) without
control switch shall be fixed on the existing plastic sheet/ gang box,
the other end of the wires shall be terminated with sufficient loose
length in a wood/PVC round block. complete for each outlet.
Short point upto 3Mtr from tapping point to out let via switch box | No | 285.0 | 285.0 | 4.0 | False | None | None | False | None | False | 1140.0 | 0 | | 2879313 | 94113 | None | 2.2.1 | Medium point above 3Mtr upto 6Mtr from tapping point to out let via
switch box | No | 394.0 | 394.0 | 4.0 | False | None | None | False | None | False | 1576.0 | 0 | | 2879314 | 94113 | None | 2.2.2 | Long point above 6Mtr upto 10Mtr from tapping point to out let via
switch box | No | 555.0 | 555.0 | 4.0 | False | None | None | False | None | False | 2220.0 | 0 | | 2879315 | 94113 | None | 3.8 | Supplying 4mm thick plastic sheet with necessary nitches for
fixing switches, regulators etc, and fixing on existing wooden or
metal box using N.F. screws | Sqm | 0.41 | 0.41 | 1500.0 | False | None | None | False | None | False | 615.0 | 0 | | 2879316 | 94113 | None | 3.1.2 | Supplying 6A flush type socket and 6 A flush type SP switch either
surface/flush mounting in existing gang box or in 4mm thick plastic
sheet and fixing over a flush mounted wooden box and wiring using
necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 Way | Each | 147.0 | 147.0 | 8.0 | False | None | None | False | None | False | 1176.0 | 0 | | 2879317 | 94113 | None | 6.3.1 | Supplying capacitor type ceiling fan complete with down rod blades,
shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase
AC supply conforming to ISS-374- 1979 and with double ball bearing
system 48" Sweep (1200 mm) Regular mode | No | 1900.0 | 1900.0 | 6.0 | False | None | None | False | None | False | 11400.0 | 0 | | 2879318 | 94113 | None | 11.13 | Supplying and fixing of slim patty fitting, made out of CRCA Sheet
metal body with locking type holder completely wired. Excluding
Ballast & Fluorescent Tube. | No | 361.0 | 361.0 | 8.0 | False | None | None | False | None | False | 2888.0 | 0 | | 2879319 | 94113 | None | 13.1.1 | Supplying and Fixing of.mm dia class A GI pipe bracket upto 2
ms long bent at suitable angle and fixing to this bracket street light
fitting of all capacities to GI or GI or rail or RCC pole / wall using
suitable clamps, bolts, and nuts and wiring using suitable capacity
wires. Using 25mm dia G.I.Pipe | No | 978.0 | 978.0 | 1.0 | False | None | None | False | None | False | 978.0 | 0 | | 2879320 | 94113 | None | 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 1.5 mm | m | 26.0 | 26.0 | 45.0 | False | None | None | False | None | False | 1170.0 | 0 | | 2879321 | 94113 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010
2.5 mm2 | m | 42.0 | 42.0 | 45.0 | False | None | None | False | None | False | 1890.0 | 0 | | 2879322 | 94113 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 4 mm2 | m | 63.0 | 63.0 | 45.0 | False | None | None | False | None | False | 2835.0 | 0 | | 2879323 | 94113 | None | 12.60.1 | Supplying&FixingChemicalearthlingforgrounding.Conduits,ICcut-outs&otherequipmentsbackfillcompoundwhichisnon-corrosive,thermallyconductive,potentialtopermissiblelimits,superiorFaultconductioncapacity,nontoxic,weatherresistance&capable of achieving ohmic value less than one ohmUsing 4ft. Copper bonded rod with backfill compound | No | 4528.0 | 4528.0 | 1.0 | False | None | None | False | None | False | 4528.0 | 0 | | 2879324 | 94113 | None | P No 23 | Pre - Paid Energy Meter Single Phase, 5-30 Amps, 1.0 Accuracy Class with Key Pad Technology consumer interface unit along with pillfer proof box | No | 7170.0 | 7170.0 | 1.0 | False | None | None | False | None | False | 7170.0 | 0 |
|
|
|---|