createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1709347271523
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee1660.00
emd156860.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose11-03-2024 16:00:00
tenderQueryClose05-03-2024 16:00:00
technicalBidOpen12-03-2024 16:15:00
publishedDate02-03-2024 09:12:46
publishedByPostRDPR_EE_DIV_KPL
publishedByUserKPE15445 - H SATHYAPPA
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonEXECUTIVE ENGINEER PRE DIVISION KOPPAL
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08539220577
mobileNumberNone
tenderSupplierListNone
tenderSchedule
createdTs1709347271577
version4
createdDateNone
modifiedDateNone
tenderNumberRDPR/2023-24/BD/WORK_INDENT4976
titleConstruction of Rooms , Const of Water Tank Supplying and Fixing of RO Plant Electrfication Toilet Cleaning Machine to KPS School Karatagi, Chikkamadinal, Navali, Kalakera, Muslapur, Hirekhed, JP Nagar Karatagi , Hirekhed, Baragur, Herror, Siddapur, Chikkajanatakal, Hulihyder, Kanakagiri, Navali Marali total 16 Nos of Kanakagiri Taluka Package No 1
descriptionConstruction of Rooms , Const of Water Tank Supplying and Fixing of RO Plant Electrfication Toilet Cleaning Machine to KPS School Karatagi, Chikkamadinal, Navali, Kalakera, Muslapur, Hirekhed, JP Nagar Karatagi , Hirekhed, Baragur, Herror, Siddapur, Chikkajanatakal, Hulihyder, Kanakagiri, Navali Marali total 16 Nos of Kanakagiri Taluka Package No 1
categoryWORKS
categoryTextWorks
ecv6607501.46
deptNameRural Development and Panchayat Raj Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location948
locationNameRDPR Division Office Koppal
provisionalAmount7843000.0
groupOverheadTotalNone
fileNumberEE/PRED/KPL/KKRDB/KNK/PACKAGE/1
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17093472720000NoneNoneBuildingsSupplying of Toilet Cleaning Machine and Repairs of School Building in KPS School at JP Nagar Karatagi247856.5
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
287894894098NoneBasic RateRO Water Plant for Hemodialysis 500 Ltrs/Hr Capacity Specifications Plant capacity (Ltrs/Hr) 500 Plant type Microprocessor/microcontroller controlled single stage RO water system ( Feed water TDS more than 500 PPM) System type Online ,Offline Double raw water pump ( one active and the other stand by) No Raw water feed pump capacity (LPH) 1500 Micron particle filter after activated Carbon filter for removing suspended particles more than micron size 5 Distribution of RO plant water sufficient for number of dialysis machines 5-10 Material of Booster pump (offline) Stainless Steel 316Nos159000.0159000.01.0FalseNoneNoneFalseNoneFalse159000.00
287894994098NoneBasic RateProviding Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. For 3 HP etc. complete. 3.00 HP - 300 LPM @ 26 m = 5 STG Outlet Dia - 2.50"Each24326.424326.41.0FalseNoneNoneFalseNoneFalse24326.40
287895094098None1.6.1Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.Nos508.2508.234.0FalseNoneNoneFalseNoneFalse17278.80
287895194098NoneBasic RateProviding, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0Each198.45198.4534.0FalseNoneNoneFalseNoneFalse6747.30
287895294098NoneBasic RateStainless Steel Top Loading Sanitary Napkin Incinerator Machine Burning Ability 500 Kg timeNo24000.024000.01.0FalseNoneNoneFalseNoneFalse24000.00
287895394098NoneI. No. 1.1.1SupplyingandwiringadoptingloopsysteminexistingPVCConduit/casingcappingusing2x1.5Sqmm(Phase&Neutral)&1x1.0sqmm(Earthwire)FRLSmultistrandPVCinsulatedcopperwire(confirmingtoIS-694:andlatestamendments)with a6AmpsflushtypeSPcontrolswitchshallbefixedontheexistingplasticsheet/gangbox,theotherendofthewiresshallbeterminatedwithsufficientlooselengthinawood/PVCroundblock.completeforeach outlet.No285.0285.01.0FalseNoneNoneFalseNoneFalse285.00
287895494098NoneI. No.2.2.2 ,)Mediumpointabove3Mtrupto6MtrfromtappingpointtooutletviaswitchNo394.0394.01.0FalseNoneNoneFalseNoneFalse394.00
287895594098None2.2.3c) Long Point using Class A. MaterialNo555.0555.01.0FalseNoneNoneFalseNoneFalse555.00
287895694098None3.1.2Supplying6Aflushtypesocketand6AflushtypeSPswitcheithersurface/flushmountinginexistinggangboxorin4mmthickplasticsheetandfixingoveraflushmountedwoodenboxandwiringusingnecessary capacity wires as required as per IS 1293 and IS 3854 b)6Amps 3/5 wayNos147.0147.04.0FalseNoneNoneFalseNoneFalse588.00
287895794098None12.60.1Supplying&FixingChemicalearthlingforgrounding.Conduits,ICcut-outs&otherequipmentsbackfillcompoundwhichisnon-corrosive,thermallyconductive,potentialtopermissiblelimits,superiorFaultconductioncapacity,nontoxic,weatherresistance&capable of achieving ohmic value less than one ohmUsing 4ft. Copper bonded rod with backfill compoundNos4528.04528.01.0FalseNoneNoneFalseNoneFalse4528.00
287895894098None9.3Supplying capacitor type ceiling fan complete with down rod blades shakle canopies for operation on 230V 50 cycles phase AC supply confirming to ISS 374-1979 and with double ball bearing system (84/9.3)Nos1900.01900.03.0FalseNoneNoneFalseNoneFalse5700.00
287895994098None11.14.2Supplyingandfixingofslimboxfitting,madeoutofCRCASheetmetalbodywithlockingtypeholdercompletelywired.ExcludingBallast & Fluorescent Tube. 1 x 4' Tube light fitting.Nos361.0361.06.0FalseNoneNoneFalseNoneFalse2166.00
287896094098None13.1.1SupplyingandFixingof.mmdiaclassAGIpipebracketupto2mslongbentatsuitableangleandfixingtothisbracketstreetlightfittingofallcapacitiestoGIorGIorrailorRCpole/wallusingsuitableclamps,bolts,andnutsandwiringusingsuitablecapacitywires. Using 25mm dia G.I.PipeNo978.0978.01.0FalseNoneNoneFalseNoneFalse978.00
287896194098NoneP No 6Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010 1.5 SqmmMtr26.026.010.0FalseNoneNoneFalseNoneFalse260.00
287896294098NoneP No 6Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010 2.5 sqmMtr42.042.010.0FalseNoneNoneFalseNoneFalse420.00
287896394098NoneP No 6Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010 4 SqmMtr63.063.010.0FalseNoneNoneFalseNoneFalse630.00
17093472720000NoneNoneBuildingsConstruction of Rooms , Const of Water Tank Supplying and Fixing of RO Plant Electrfication Toilet Cleaning Machine to GHPS School at Chikamadinal Village1815402.37
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
287896494099None1.4Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.Cum254.1254.141.513FalseNoneNoneFalseNoneFalse10548.45330
287896594099None2.1.1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates work as per technical specificationsCum5947.25947.212.72FalseNoneNoneFalseNoneFalse75648.3840
287896694099None5.2Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6948.96948.911.31FalseNoneNoneFalseNoneFalse78592.0590
287896794099None5.3Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sandCum6515.256515.258.11FalseNoneNoneFalseNoneFalse52838.67750
287896894099None5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6708.456708.4512.3FalseNoneNoneFalseNoneFalse82513.9350
287896994099None1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum279.3279.345.9FalseNoneNoneFalseNoneFalse12819.870
287897094099None2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6601.356601.3526.33FalseNoneNoneFalseNoneFalse173813.54550
287897194099None2.5.1Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cumSqm330.07330.071.73FalseNoneNoneFalseNoneFalse571.02110
287897294099None2.5.1Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cumSqm660.14660.142.73FalseNoneNoneFalseNoneFalse1802.18220
287897394099None2.5.1Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cumSqm3960.813960.815.76FalseNoneNoneFalseNoneFalse22814.26560
287897494099None2.5.1Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cumSqm3300.683300.6813.1FalseNoneNoneFalseNoneFalse43238.9080
287897594099None2.11Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Tonne93929.8593929.852.75FalseNoneNoneFalseNoneFalse258307.08750
287897694099None6.7Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum8621.558621.5519.64FalseNoneNoneFalseNoneFalse169327.2420
287897794099None11.34BProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.Sqm192.15192.15177.66FalseNoneNoneFalseNoneFalse34137.3690
287897894099None8.6.1Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerin-charge.Sqm339.15339.1584.78FalseNoneNoneFalseNoneFalse28753.1370
287897994099None8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-chargeSqm279.3279.3115.38FalseNoneNoneFalseNoneFalse32225.6340
287898094099None8.33.1Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life)Sqm165.9165.984.78FalseNoneNoneFalseNoneFalse14065.0020
287898194099None8.29Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm297.15297.15115.38FalseNoneNoneFalseNoneFalse34285.1670
287898294099None9.12.2Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mmSqm1202.251202.2557.8FalseNoneNoneFalseNoneFalse69490.050
287898394099None9.34Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specificationsSqm1622.251622.2518.7FalseNoneNoneFalseNoneFalse30336.0750
287898494099None12.12Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. Cum130412.1130412.10.24FalseNoneNoneFalseNoneFalse31298.9040
287898594099None12.15Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures )Sqm7816.27816.28.28FalseNoneNoneFalseNoneFalse64718.1360
287898694099None12.55.1Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hingesSqm2484.32484.31.58FalseNoneNoneFalseNoneFalse3925.1940
287898794099None8.49Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeNo4.24.27000.0FalseNoneNoneFalseNoneFalse29400.00
287898894099None88.84Providing Wall black in 12 mm thick with CM 1:3 and applied with primer and two coats of acyrlic emulsion black paint including finishing etc completeSqm498.75498.753.6FalseNoneNoneFalseNoneFalse1795.50
287898994099None12.80Providing and Fixing door latch with necessary screws etc completeSqm299.25299.253.6FalseNoneNoneFalseNoneFalse1077.30
287899094099None20.27.3Providing and Fixing bright finished brass flush bolts with necessary brass screws etc cpmpleteEach172.2172.222.0FalseNoneNoneFalseNoneFalse3788.40
287899194099None1.1.1Electrification:Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.19/20 mm dia 2 mm thickMtr69.069.040.0FalseNoneNoneFalseNoneFalse2760.00
287899294099None1.4.1Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc 75 x 75 x 65 mmNos106.0106.04.0FalseNoneNoneFalseNoneFalse424.00
287899394099None2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point upto 3Mtr from tapping point to out let via switch boxNos285.0285.04.0FalseNoneNoneFalseNoneFalse1140.00
287899494099None2.2.3Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxNos394.0394.04.0FalseNoneNoneFalseNoneFalse1576.00
287899594099None2.2.3Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxNos555.0555.04.0FalseNoneNoneFalseNoneFalse2220.00
287899694099None3.8Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screws.Sqm0.410.411500.0FalseNoneNoneFalseNoneFalse615.00
287899794099None3.1.2Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 WayNos147.0147.012.0FalseNoneNoneFalseNoneFalse1764.00
287899894099None12.60Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is noncorrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm Using 4ft. Copper bonded rod with backfill compoundNos4528.04528.01.0FalseNoneNoneFalseNoneFalse4528.00
287899994099None6.3Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing systemNos1900.01900.06.0FalseNoneNoneFalseNoneFalse11400.00
287900094099None11.14.2Supplying and fixing of slim box fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube 1 x 4' Tube light fittingNos361.0361.06.0FalseNoneNoneFalseNoneFalse2166.00
287900194099None13.1.1Supplying and Fixing of.mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires Using 25mm dia G.I.PipeNos978.0978.01.0FalseNoneNoneFalseNoneFalse978.00
287900294099NoneP No 23Pre - Paid Energy Meter Single Phase, 5-30 Amps, 1.0 Accuracy Class with Key Pad Technology consumer interface unit along with pillfer proof boxNo7170.07170.01.0FalseNoneNoneFalseNoneFalse7170.00
287900394099NoneP No 6Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.5 mmMtr26.026.040.0FalseNoneNoneFalseNoneFalse1040.00
287900494099NoneP No 6Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 2.5 mmMtr42.042.040.0FalseNoneNoneFalseNoneFalse1680.00
287900594099NoneP No 6Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:20104 mm2Mtr63.063.040.0FalseNoneNoneFalseNoneFalse2520.00
287900694099NoneI No.8.33.1 (Volume 2)Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign atter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm165.9165.972.0FalseNoneNoneFalseNoneFalse11944.80
287900794099None19.22Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction of Engineer-in-chargeCum50.450.481.2FalseNoneNoneFalseNoneFalse4092.480
287900894099None2.1.1Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required t complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M7.5) Using 40 mm nominal size graded crushed coarse aggregates Cum5947.25947.28.12FalseNoneNoneFalseNoneFalse48291.2640
287900994099None9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grou ting the joints with white cement and matching pigments etc., complete. (Size of Tile 600x600 mm)Sqm1202.251202.2586.32FalseNoneNoneFalseNoneFalse103778.220
287901094099None1.1.1SupplyingheavygaugePVCconduitpipe.dia.mmthickconfirmingtoIS2509withsuitablesizebends,junctionboxes,adhesivepasteetc,andfixingusinginvertedwoodplugsincaseofRCCceilingandRCCwall/stonestructureorrawlplugsincaseofbrickwallsandcementplasteringthedamagedportionusingheavygauge saddles at an interval of 700mm using NF screws.Mtr69.069.020.0FalseNoneNoneFalseNoneFalse1380.00
287901194099NoneBasic RateSupplyingandfixingsheetMetalboxmadeoutof18SWGsheetmetalwithnecessaryholesforcable/conduitentryasrequiredwithonecoat of primer of approved make etc.Nos106.0106.04.0FalseNoneNoneFalseNoneFalse424.00
287901294099None2.2.1 SupplyingandwiringadoptingloopsysteminexistingPVCConduit/casingcappingusing2x1.5Sqmm(Phase&Neutral)&1x1.0sqmm(Earthwire)FRLSmultistrandPVCinsulatedcopperwire(confirmingtoIS-694:andlatestamendments)with a6AmpsflushtypeSPcontrolswitchshallbefixedontheexistingplasticsheet/gangbox,theotherendofthewiresshallbeterminatedwithsufficientlooselengthinawood/PVCroundblock.completeforeach outlet. a) Short Point using Class A. MaterialNo285.0285.02.0FalseNoneNoneFalseNoneFalse570.00
287901394099None2.2.3SupplyingandwiringadoptingloopsysteminexistingPVCConduit/casingcappingusing2x1.5Sqmm(Phase&Neutral)&1x1.0sqmm(Earthwire)FRLSmultistrandPVCinsulatedcopperwire(confirmingtoIS-694:andlatestamendments)with a6AmpsflushtypeSPcontrolswitchshallbefixedontheexistingplasticsheet/gangbox,theotherendofthewiresshallbeterminatedwithsufficientlooselengthinawood/PVCroundblock.completeforeach outlet. Mediumpointabove3Mtrupto6MtrfromtappingpointtooutletviaswitchnoNo394.0394.02.0FalseNoneNoneFalseNoneFalse788.00
287901494099None2.2.3SupplyingandwiringadoptingloopsysteminexistingPVCConduit/casingcappingusing2x1.5Sqmm(Phase&Neutral)&1x1.0sqmm(Earthwire)FRLSmultistrandPVCinsulatedcopperwire(confirmingtoIS-694:andlatestamendments)with a6AmpsflushtypeSPcontrolswitchshallbefixedontheexistingplasticsheet/gangbox,theotherendofthewiresshallbeterminatedwithsufficientlooselengthinawood/PVCroundblock.completeforeach outlet.c) Long Point using Class A. MaterialNo555.0555.02.0FalseNoneNoneFalseNoneFalse1110.00
287901594099None3.8Supplying4mmthickplasticsheetwithnecessarynitchesforfixingswitches,regulatorsetc,andfixingonexistingwoodenormetal box using N.F. screws.Sqm0.410.411000.0FalseNoneNoneFalseNoneFalse410.00
287901694099None3.1.2Supplying6Aflushtypesocketand6AflushtypeSPswitcheithersurface/flushmountinginexistinggangboxorin4mmthickplasticsheetandfixingoveraflushmountedwoodenboxandwiringusingnecessary capacity wires as required as per IS 1293 and IS 3854No147.0147.05.0FalseNoneNoneFalseNoneFalse735.00
287901794099None9.13Supplying capacitor type ceiling fan complete with down rod blades shakle canopies for operation on 230V 50 cycles phase AC supply confirming to ISS 374-1979 and with double ball bearing system (84/9.3)No1900.01900.01.0FalseNoneNoneFalseNoneFalse1900.00
287901894099None11.14.2Supplyingandfixingofslimboxfitting,madeoutofCRCASheetmetalbodywithlockingtypeholdercompletelywired.ExcludingBallast & Fluorescent Tube. 1 x 4' Tube light fitting.No361.0361.02.0FalseNoneNoneFalseNoneFalse722.00
287901994099NoneI. No.2.3.2,3.2.2.3,3.235.4)Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010 1.5 sqmMtr26.026.015.0FalseNoneNoneFalseNoneFalse390.00
287902094099NoneI. No.2.3.2,3.2.2.3,3.235.4)Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010 2.5 sqmMtr42.042.015.0FalseNoneNoneFalseNoneFalse630.00
287902194099NoneI. No.2.3.2,3.2.2.3,3.235.4)Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010 4 sqmMtr63.063.015.0FalseNoneNoneFalseNoneFalse945.00
287902294099NoneBasic Ratecleaning machin Stainless Steel Top Loading Sanitary Napkin Incinerator Machine, Burning Ability: 500 Kg/timeNo24000.024000.01.0FalseNoneNoneFalseNoneFalse24000.00
287902394099NoneBasic RateRO Water Plant for Hemodialysis 500 Ltrs/Hr Capacity Specifications Plant capacity (Ltrs/Hr) 500 Plant type Microprocessor/microcontroller controlled single stage RO water system ( Feed water TDS more than 500 PPM) System type Online ,Offline Double raw water pump ( one active and the other stand by) No Raw water feed pump capacity (LPH) 1500 Micron particle filter after activated Carbon filter for removing suspended particles more than micron size 5 Distribution of RO plant water sufficient for number of dialysis machines 5-10 Material of Booster pump (offline) Stainless Steel 316No159000.0159000.01.0FalseNoneNoneFalseNoneFalse159000.00
287902494099None13.11.1Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. For 3 HP etc. complete. 3.00 HP - 300 LPM @ 26 m = 5 STG Outlet Dia - 2.50"Each23326.423326.41.0FalseNoneNoneFalseNoneFalse23326.40
287902594099NoneI No.1.6.1 (Volume 1)Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.No508.2508.238.0FalseNoneNoneFalseNoneFalse19311.60
287902694099NoneI No.9.1.1 (Volume 5)Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0No198.45198.4538.0FalseNoneNoneFalseNoneFalse7541.10
17093472720000NoneNoneBuildingsSupplying of Toilet Cleaning Machine Repairs of Electrification Water Supply and Installation of RO Plant at Navali School255945.45
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
287902794100NoneBasic RateRO Water Plant for Hemodialysis 500 Ltrs/Hr Capacity Specifications Plant capacity (Ltrs/Hr) 500 Plant type Microprocessor/microcontroller controlled single stage RO water system ( Feed water TDS more than 500 PPM) System type Online ,Offline Double raw water pump ( one active and the other stand by) No Raw water feed pump capacity (LPH) 1500 Micron particle filter after activated Carbon filter for removing suspended particles more than micron size 5 Distribution of RO plant water sufficient for number of dialysis machines 5-10 Material of Booster pump (offline) Stainless Steel 316No160000.0160000.01.0FalseNoneNoneFalseNoneFalse160000.00
287902894100None1.6.1Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.In all kinds of soils. Depth upto 1.50mNo508.2508.236.0FalseNoneNoneFalseNoneFalse18295.20
287902994100None13.11.1Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. For 3 HP etc. complete. 3.00 HP - 300 LPM @ 26 m = 5 STG Outlet Dia - 2.50"Each24326.424326.41.0FalseNoneNoneFalseNoneFalse24326.40
287903094100None9.1.1Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0 HDPE Grade PE80-PN6.0, 63mm diaMtr198.45198.4533.0FalseNoneNoneFalseNoneFalse6548.850
287903194100None1.1.1SupplyingheavygaugePVCconduitpipe.dia.mmthickconfirmingtoIS2509withsuitablesizebends,junctionboxes,adhesivepasteetc,andfixingusinginvertedwoodplugsincaseofRCCceilingandRCCwall/stonestructureorrawlplugsincaseofbrickwallsandcementplasteringthedamagedportionusingheavygauge saddles at an interval of 700mm using NF screws.Mtr69.069.020.0FalseNoneNoneFalseNoneFalse1380.00
287903294100None1.4.1SupplyingandfixingsheetMetalboxmadeoutof18SWGsheetmetalwithnecessaryholesforcable/conduitentryasrequiredwithonecoat of primer of approved make etc.No106.0106.04.0FalseNoneNoneFalseNoneFalse424.00
287903394100None2.2.1SupplyingandwiringadoptingloopsysteminexistingPVCConduit/casingcappingusing2x1.5Sqmm(Phase&Neutral)&1x1.0sqmm(Earthwire)FRLSmultistrandPVCinsulatedcopperwire(confirmingtoIS-694:andlatestamendments)with a6AmpsflushtypeSPcontrolswitchshallbefixedontheexistingplasticsheet/gangbox,theotherendofthewiresshallbeterminatedwithsufficientlooselengthinawood/PVCroundblock.completeforeach outlet.a) Short Point using Class A. MaterialNo285.0285.05.0FalseNoneNoneFalseNoneFalse1425.00
287903494100None2.2.2SupplyingandwiringadoptingloopsysteminexistingPVCConduit/casingcappingusing2x1.5Sqmm(Phase&Neutral)&1x1.0sqmm(Earthwire)FRLSmultistrandPVCinsulatedcopperwire(confirmingtoIS-694:andlatestamendments)with a6AmpsflushtypeSPcontrolswitchshallbefixedontheexistingplasticsheet/gangbox,theotherendofthewiresshallbeterminatedwithsufficientlooselengthinawood/PVCroundblock.completeforeach outlet.Mediumpointabove3Mtrupto6MtrfromtappingpointtooutletviaswitchNos394.0394.05.0FalseNoneNoneFalseNoneFalse1970.00
287903594100None2.2.3SupplyingandwiringadoptingloopsysteminexistingPVCConduit/casingcappingusing2x1.5Sqmm(Phase&Neutral)&1x1.0sqmm(Earthwire)FRLSmultistrandPVCinsulatedcopperwire(confirmingtoIS-694:andlatestamendments)with a6AmpsflushtypeSPcontrolswitchshallbefixedontheexistingplasticsheet/gangbox,theotherendofthewiresshallbeterminatedwithsufficientlooselengthinawood/PVCroundblock.completeforeach outlet.c) Long Point using Class A. MaterialPoint555.0555.05.0FalseNoneNoneFalseNoneFalse2775.00
287903694100None3.8Supplying4mmthickplasticsheetwithnecessarynitchesforfixingswitches,regulatorsetc,andfixingonexistingwoodenormetal box using N.F. screws.Sqm0.410.41800.0FalseNoneNoneFalseNoneFalse328.00
287903794100None3.1.2Supplying6Aflushtypesocketand6AflushtypeSPswitcheithersurface/flushmountinginexistinggangboxorin4mmthickplasticsheetandfixingoveraflushmountedwoodenboxandwiringusingnecessary capacity wires as required as per IS 1293 and IS 3854No147.0147.08.0FalseNoneNoneFalseNoneFalse1176.00
287903894100None9.3Supplying capacitor type ceiling fan complete with down rod blades shakle canopies for operation on 230V 50 cycles phase AC supply confirming to ISS 374-1979 and with double ball bearing system (84/9.3)No1900.01900.04.0FalseNoneNoneFalseNoneFalse7600.00
287903994100None11.14.2Supplyingandfixingofslimboxfitting,madeoutofCRCASheetmetalbodywithlockingtypeholdercompletelywired.ExcludingBallast & Fluorescent Tube. 1 x 4' Tube light fitting.No361.0361.04.0FalseNoneNoneFalseNoneFalse1444.00
287904094100None13.1.1SupplyingandFixingof.mmdiaclassAGIpipebracketupto2mslongbentatsuitableangleandfixingtothisbracketstreetlightfittingofallcapacitiestoGIorGIorrailorRCpole/wallusingsuitableclamps,bolts,andnutsandwNo978.0978.01.0FalseNoneNoneFalseNoneFalse978.00
287904194100NoneI. No.2.3.2,3.2.2.3,3.235.4)Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010 1.5 SqmMtr26.026.025.0FalseNoneNoneFalseNoneFalse650.00
287904294100NoneI. No.2.3.2,3.2.2.3,3.235.4)Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010 2.5 SqmMtr42.042.025.0FalseNoneNoneFalseNoneFalse1050.00
287904394100NoneI. No.2.3.2,3.2.2.3,3.235.4)Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010 4 sqmMtr63.063.025.0FalseNoneNoneFalseNoneFalse1575.00
287904494100NoneBasic Ratecleaning machin Stainless Steel Top Loading Sanitary Napkin Incinerator Machine, Burning Ability: 500 Kg/timeNo24000.024000.01.0FalseNoneNoneFalseNoneFalse24000.00
17093472720000NoneNoneBuildingsConst of Water Tank Supplying and Fixing of RO Plant Electrfication Toilet Cleaning Machine to GHPS School at Kalakeri Village440738.98
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
287904594101NoneBasic RateRO Water Plant for Hemodialysis 500 Ltrs/Hr Capacity Specifications Plant capacity (Ltrs/Hr) 500 Plant type Microprocessor/microcontroller controlled single stage RO water system ( Feed water TDS more than 500 PPM) System type Online ,Offline Double raw water pump ( one active and the other stand by) No Raw water feed pump capacity (LPH) 1500 Micron particle filter after activated Carbon filter for removing suspended particles more than micron size 5 Distribution of RO plant water sufficient for number of dialysis machines 5-10 Material of Booster pump (offline) Stainless Steel 316No160000.0160000.01.0FalseNoneNoneFalseNoneFalse160000.00
287904694101None1.6.1Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.No508.2508.235.0FalseNoneNoneFalseNoneFalse17787.00
287904794101None13.11.1Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. For 3 HP etc. complete. 3.00 HP - 300 LPM @ 26 m = 5 STG Outlet Dia - 2.50"Each24326.424326.41.0FalseNoneNoneFalseNoneFalse24326.40
287904894101None9.1.1Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0 HDPE Grade PE80-PN6.0, 63mm diaMtr198.45198.4535.0FalseNoneNoneFalseNoneFalse6945.750
287904994101NoneBasic RateStainless Steel Top Loading Sanitary Napkin Incinerator Machine Burning Ability 500 kg TimeNo24000.024000.01.0FalseNoneNoneFalseNoneFalse24000.00
287905094101None1.1.1Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc 75 x 75 x 65 mmNo106.0106.08.0FalseNoneNoneFalseNoneFalse848.00
287905194101None2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch boxNo285.0285.08.0FalseNoneNoneFalseNoneFalse2280.00
287905294101None2.2.1Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxNo394.0394.08.0FalseNoneNoneFalseNoneFalse3152.00
287905394101None2.2.2Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxNo555.0555.08.0FalseNoneNoneFalseNoneFalse4440.00
287905494101None3.8Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screwsSqm0.410.411500.0FalseNoneNoneFalseNoneFalse615.00
287905594101None3.1.2Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 WayEach147.0147.018.0FalseNoneNoneFalseNoneFalse2646.00
287905694101None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 48" Sweep (1200 mm) Regular modeNo1900.01900.06.0FalseNoneNoneFalseNoneFalse11400.00
287905794101None11.13Supplying and fixing of slim patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube.No361.0361.08.0FalseNoneNoneFalseNoneFalse2888.00
287905894101None13.1.1Supplying and Fixing of.mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires. Using 25mm dia G.I.PipeNo978.0978.01.0FalseNoneNoneFalseNoneFalse978.00
287905994101None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.5 mmm26.026.055.0FalseNoneNoneFalseNoneFalse1430.00
287906094101None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 2.5 mm2m42.042.055.0FalseNoneNoneFalseNoneFalse2310.00
287906194101None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 4 mm2m63.063.055.0FalseNoneNoneFalseNoneFalse3465.00
287906294101None1.1.1SupplyingheavygaugePVCconduitpipe.dia.mmthickconfirmingtoIS2509withsuitablesizebends,junctionboxes,adhesivepasteetc,andfixingusinginvertedwoodplugsincaseofRCCceilingandRCCwall/stonestructureorrawlplugsincaseofbrickwallsandcementplasteringthedamagedportionusingheavygauge saddles at an interval of 700mm using NF screws.Mtr69.069.055.0FalseNoneNoneFalseNoneFalse3795.00
287906394101None1.4Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.Cum254.1254.16.75FalseNoneNoneFalseNoneFalse1715.1750
287906494101None2.1.1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates work as per technical specificationsCum5947.25947.21.4FalseNoneNoneFalseNoneFalse8326.080
287906594101None5.2Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6948.96948.91.5FalseNoneNoneFalseNoneFalse10423.350
287906694101None5.3Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sandCum6515.256515.251.2FalseNoneNoneFalseNoneFalse7818.30
287906794101None5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6708.456708.452.7FalseNoneNoneFalseNoneFalse18112.8150
287906894101None1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum279.3279.33.6FalseNoneNoneFalseNoneFalse1005.480
287906994101None2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6601.356601.351.1FalseNoneNoneFalseNoneFalse7261.4850
287907094101None2.5.1Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cumSqm3960.813960.810.35FalseNoneNoneFalseNoneFalse1386.28350
287907194101None2.5.1Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cumSqm3300.683300.680.75FalseNoneNoneFalseNoneFalse2475.510
287907294101None2.11Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Tonne93929.8593929.850.1FalseNoneNoneFalseNoneFalse9392.9850
287907394101None6.7Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum8621.558621.554.14FalseNoneNoneFalseNoneFalse35693.2170
287907494101None8.6.1Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerin-charge.Sqm339.15339.1551.0FalseNoneNoneFalseNoneFalse17296.650
287907594101None8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm120.75120.7551.0FalseNoneNoneFalseNoneFalse6158.250
287907694101None13.2.1Providing and fixing brass bib cock of approved quality :Each300.3300.35.0FalseNoneNoneFalseNoneFalse1501.50
287907794101None1.6.1Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.No508.2508.255.0FalseNoneNoneFalseNoneFalse27951.00
287907894101None9.1.1Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0 HDPE Grade PE80-PN6.0, 63mm diaMtr198.45198.4555.0FalseNoneNoneFalseNoneFalse10914.750
17093472720000NoneNoneBuildingsConstruction of Room Repairs of Electrfication and Supplying of Toilet Cleaning Machine at GHPS at Musalapur Village1594646.08
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
287907994102None1.4Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.Cum254.1254.141.513FalseNoneNoneFalseNoneFalse10548.45330
287908094102None2.1.1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates work as per technical specificationsCum5947.25947.212.72FalseNoneNoneFalseNoneFalse75648.3840
287908194102None5.2Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6948.96948.911.31FalseNoneNoneFalseNoneFalse78592.0590
287908294102None5.3Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sandCum6515.256515.258.11FalseNoneNoneFalseNoneFalse52838.67750
287908394102None5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6708.456708.4512.3FalseNoneNoneFalseNoneFalse82513.9350
287908494102None1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum279.3279.345.9FalseNoneNoneFalseNoneFalse12819.870
287908594102None2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6601.356601.3526.33FalseNoneNoneFalseNoneFalse173813.54550
287908694102None2.5.1Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cumSqm330.07330.071.73FalseNoneNoneFalseNoneFalse571.02110
287908794102None2.5.1Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cumSqm660.14660.142.73FalseNoneNoneFalseNoneFalse1802.18220
287908894102None2.5.1Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cumSqm3960.813960.815.76FalseNoneNoneFalseNoneFalse22814.26560
287908994102None2.5.1Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cumSqm3300.683300.6813.1FalseNoneNoneFalseNoneFalse43238.9080
287909094102None2.11Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Tonne93929.8593929.852.75FalseNoneNoneFalseNoneFalse258307.08750
287909194102None6.7Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum8621.558621.5519.64FalseNoneNoneFalseNoneFalse169327.2420
287909294102None11.34BProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.Sqm192.15192.15177.66FalseNoneNoneFalseNoneFalse34137.3690
287909394102None8.6.1Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerin-charge.Sqm339.15339.1584.78FalseNoneNoneFalseNoneFalse28753.1370
287909494102None8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-chargeSqm279.3279.3115.38FalseNoneNoneFalseNoneFalse32225.6340
287909594102None8.33.1Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life)Sqm165.9165.984.78FalseNoneNoneFalseNoneFalse14065.0020
287909694102None8.29Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm297.15297.15115.38FalseNoneNoneFalseNoneFalse34285.1670
287909794102None9.12.2Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mmSqm1202.251202.2557.8FalseNoneNoneFalseNoneFalse69490.050
287909894102None9.34Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specificationsSqm1622.251622.2518.7FalseNoneNoneFalseNoneFalse30336.0750
287909994102None12.12Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. Cum130412.1130412.10.24FalseNoneNoneFalseNoneFalse31298.9040
287910094102None12.15Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures )Sqm7816.27816.28.28FalseNoneNoneFalseNoneFalse64718.1360
287910194102None8.49Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeNo4.24.27000.0FalseNoneNoneFalseNoneFalse29400.00
287910294102None88.84Providing Wall black in 12 mm thick with CM 1:3 and applied with primer and two coats of acyrlic emulsion black paint including finishing etc completeSqm498.75498.753.6FalseNoneNoneFalseNoneFalse1795.50
287910394102None12.80Providing and Fixing door latch with necessary screws etc completeSqm299.25299.253.6FalseNoneNoneFalseNoneFalse1077.30
287910494102None20.27.3Providing and Fixing bright finished brass flush bolts with necessary brass screws etc cpmpleteEach172.2172.222.0FalseNoneNoneFalseNoneFalse3788.40
287910594102None1.1.1Electrification:Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.19/20 mm dia 2 mm thickMtr69.069.040.0FalseNoneNoneFalseNoneFalse2760.00
287910694102None1.4.1Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc 75 x 75 x 65 mmNos106.0106.04.0FalseNoneNoneFalseNoneFalse424.00
287910794102None2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point upto 3Mtr from tapping point to out let via switch boxNos285.0285.04.0FalseNoneNoneFalseNoneFalse1140.00
287910894102None2.2.3Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxNos394.0394.04.0FalseNoneNoneFalseNoneFalse1576.00
287910994102None2.2.3Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxNos555.0555.04.0FalseNoneNoneFalseNoneFalse2220.00
287911094102None3.8Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screws.Sqm0.410.411500.0FalseNoneNoneFalseNoneFalse615.00
287911194102None3.1.2Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 WayNos147.0147.016.0FalseNoneNoneFalseNoneFalse2352.00
287911294102None12.60Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is noncorrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm Using 4ft. Copper bonded rod with backfill compoundNos4528.04528.01.0FalseNoneNoneFalseNoneFalse4528.00
287911394102None6.3Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing systemNos1900.01900.02.0FalseNoneNoneFalseNoneFalse3800.00
287911494102None11.14.2Supplying and fixing of slim box fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube 1 x 4' Tube light fittingNos361.0361.04.0FalseNoneNoneFalseNoneFalse1444.00
287911594102None13.1.1Supplying and Fixing of.mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires Using 25mm dia G.I.PipeNos978.0978.01.0FalseNoneNoneFalseNoneFalse978.00
287911694102NoneP No 23Pre - Paid Energy Meter Single Phase, 5-30 Amps, 1.0 Accuracy Class with Key Pad Technology consumer interface unit along with pillfer proof boxNo7170.07170.01.0FalseNoneNoneFalseNoneFalse7170.00
287911794102NoneP No 6Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.5 mmMtr26.026.040.0FalseNoneNoneFalseNoneFalse1040.00
287911894102NoneP No 6Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 2.5 mmMtr42.042.040.0FalseNoneNoneFalseNoneFalse1680.00
287911994102NoneP No 6Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:20104 mm2Mtr63.063.040.0FalseNoneNoneFalseNoneFalse2520.00
287912094102None8.33.1Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign atter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm165.9165.972.0FalseNoneNoneFalseNoneFalse11944.80
287912194102None19.22Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction of Engineer-in-chargeCum50.450.481.2FalseNoneNoneFalseNoneFalse4092.480
287912294102None2.1.1Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required t complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M7.5) Using 40 mm nominal size graded crushed coarse aggregates Cum5947.25947.28.12FalseNoneNoneFalseNoneFalse48291.2640
287912394102None9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grou ting the joints with white cement and matching pigments etc., complete. (Size of Tile 600x600 mm)Sqm1202.251202.2586.32FalseNoneNoneFalseNoneFalse103778.220
287912494102None1.1.1SupplyingheavygaugePVCconduitpipe.dia.mmthickconfirmingtoIS2509withsuitablesizebends,junctionboxes,adhesivepasteetc,andfixingusinginvertedwoodplugsincaseofRCCceilingandRCCwall/stonestructureorrawlplugsincaseofbrickwallsandcementplasteringthedamagedportionusingheavygauge saddles at an interval of 700mm using NF screws.Mtr69.069.020.0FalseNoneNoneFalseNoneFalse1380.00
287912594102NoneBasic RateStainless Steel Top Loading Sanitary Napkin Incinerator Machine Burning Ability 500 kg TimeNo24000.024000.01.0FalseNoneNoneFalseNoneFalse24000.00
287912694102None1.1.1Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc 75 x 75 x 65 mmNo106.0106.02.0FalseNoneNoneFalseNoneFalse212.00
287912794102None2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch boxNo285.0285.02.0FalseNoneNoneFalseNoneFalse570.00
287912894102None2.2.1Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxNo394.0394.02.0FalseNoneNoneFalseNoneFalse788.00
287912994102None2.2.2Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxNo555.0555.02.0FalseNoneNoneFalseNoneFalse1110.00
287913094102None3.8Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screwsSqm0.410.411000.0FalseNoneNoneFalseNoneFalse410.00
287913194102None3.1.2Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 WayEach147.0147.05.0FalseNoneNoneFalseNoneFalse735.00
287913294102None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 48" Sweep (1200 mm) Regular modeNo1900.01900.01.0FalseNoneNoneFalseNoneFalse1900.00
287913394102None11.13Supplying and fixing of slim patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube.No361.0361.01.0FalseNoneNoneFalseNoneFalse361.00
287913494102None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.5 mmm26.026.020.0FalseNoneNoneFalseNoneFalse520.00
287913594102None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 2.5 mm2m42.042.020.0FalseNoneNoneFalseNoneFalse840.00
287913694102None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 4 mm2m63.063.020.0FalseNoneNoneFalseNoneFalse1260.00
17093472720000NoneNoneBuildingsRepairs of 2 Room Building Electrification and Supplying of Toilet Cleaning Machine at GHPS School at Hirekhed Village370648.8
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
287913794103None8.72.1Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign atter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm91.3591.35227.1FalseNoneNoneFalseNoneFalse20745.5850
287913894103None15.2Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2 l/per m2, having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 l/m2, and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification.Sqm773.85773.85130.9FalseNoneNoneFalseNoneFalse101296.9650
287913994103None19.22Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction of Engineer-in-chargeCum50.450.496.2FalseNoneNoneFalseNoneFalse4848.480
287914094103None2.1.1Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required t complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M7.5) Using 40 mm nominal size graded crushed coarse aggregates Cum5947.25947.212.03FalseNoneNoneFalseNoneFalse71544.8160
287914194103None9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grou ting the joints with white cement and matching pigments etc., complete. (Size of Tile 600x600 mm)Sqm1202.251202.25101.76FalseNoneNoneFalseNoneFalse122340.960
287914294103NoneBasic RateStainless Steel Top Loading Sanitary Napkin Incinerator Machine Burning Ability 500 kg TimeNo24000.024000.01.0FalseNoneNoneFalseNoneFalse24000.00
287914394103None1.1.1Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc 75 x 75 x 65 mmNo106.0106.04.0FalseNoneNoneFalseNoneFalse424.00
287914494103None2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch boxNo285.0285.04.0FalseNoneNoneFalseNoneFalse1140.00
287914594103None2.2.1Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxNo394.0394.04.0FalseNoneNoneFalseNoneFalse1576.00
287914694103None2.2.2Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxNo555.0555.04.0FalseNoneNoneFalseNoneFalse2220.00
287914794103None3.8Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screwsSqm0.410.411000.0FalseNoneNoneFalseNoneFalse410.00
287914894103None3.1.2Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 WayEach147.0147.05.0FalseNoneNoneFalseNoneFalse735.00
287914994103None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 48" Sweep (1200 mm) Regular modeNo1900.01900.07.0FalseNoneNoneFalseNoneFalse13300.00
287915094103None11.13Supplying and fixing of slim patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube.No361.0361.02.0FalseNoneNoneFalseNoneFalse722.00
287915194103None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.5 mmm26.026.025.0FalseNoneNoneFalseNoneFalse650.00
287915294103None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 2.5 mm2m42.042.025.0FalseNoneNoneFalseNoneFalse1050.00
287915394103None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 4 mm2m63.063.025.0FalseNoneNoneFalseNoneFalse1575.00
287915494103None1.1.1SupplyingheavygaugePVCconduitpipe.dia.mmthickconfirmingtoIS2509withsuitablesizebends,junctionboxes,adhesivepasteetc,andfixingusinginvertedwoodplugsincaseofRCCceilingandRCCwall/stonestructureorrawlplugsincaseofbrickwallsandcementplasteringthedamagedportionusingheavygauge saddles at an interval of 700mm using NF screws.Mtr69.069.030.0FalseNoneNoneFalseNoneFalse2070.00
17093472720000NoneNoneBuildingsRepairs of Building and Supplying of Toilet Cleaning Machine at KPS School at Karatagi Village191309.02
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
287915594104None19.22Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction of Engineer-in-chargeCum50.450.496.0FalseNoneNoneFalseNoneFalse4838.40
287915694104None2.1.1Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required t complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M7.5) Using 40 mm nominal size graded crushed coarse aggregatesCum5947.25947.26.78FalseNoneNoneFalseNoneFalse40322.0160
287915794104None9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grou ting the joints with white cement and matching pigments etc., complete. (Size of Tile 600x600 mm)Sqm1202.251202.25101.6FalseNoneNoneFalseNoneFalse122148.60
287915894104NoneBasic RateStainless Steel Top Loading Sanitary Napkin Incinerator Machine Burning ability 500 KgNo24000.024000.01.0FalseNoneNoneFalseNoneFalse24000.00
17093472720000NoneNoneBuildingsRepairs of Room Const of Water Tank Supplying and Reapirs of Electrfication Toilet Cleaning Machine to Govt School at Hirekhed Village352850.59
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
287915994105None8.33.1Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign atter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm165.9165.972.0FalseNoneNoneFalseNoneFalse11944.80
287916094105None19.22Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction of Engineer-in-chargeCum50.450.481.2FalseNoneNoneFalseNoneFalse4092.480
287916194105None2.1.1Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required t complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M7.5) Using 40 mm nominal size graded crushed coarse aggregates Cum5947.25947.28.12FalseNoneNoneFalseNoneFalse48291.2640
287916294105None9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grou ting the joints with white cement and matching pigments etc., complete. (Size of Tile 600x600 mm)Sqm1202.251202.2586.32FalseNoneNoneFalseNoneFalse103778.220
287916394105None1.1.1Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc 75 x 75 x 65 mmNo106.0106.04.0FalseNoneNoneFalseNoneFalse424.00
287916494105None2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch boxNo285.0285.02.0FalseNoneNoneFalseNoneFalse570.00
287916594105None2.2.1Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxNo394.0394.02.0FalseNoneNoneFalseNoneFalse788.00
287916694105None2.2.2Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxNo555.0555.02.0FalseNoneNoneFalseNoneFalse1110.00
287916794105None3.8Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screwsSqm0.410.411000.0FalseNoneNoneFalseNoneFalse410.00
287916894105None3.1.2Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 WayEach147.0147.05.0FalseNoneNoneFalseNoneFalse735.00
287916994105None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 48" Sweep (1200 mm) Regular modeNo1900.01900.04.0FalseNoneNoneFalseNoneFalse7600.00
287917094105None11.13Supplying and fixing of slim patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube.No361.0361.02.0FalseNoneNoneFalseNoneFalse722.00
287917194105None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.5 mmm26.026.022.0FalseNoneNoneFalseNoneFalse572.00
287917294105None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 2.5 mm2m42.042.022.0FalseNoneNoneFalseNoneFalse924.00
287917394105None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 4 mm2m63.063.022.0FalseNoneNoneFalseNoneFalse1386.00
287917494105None1.4Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.Cum254.1254.16.75FalseNoneNoneFalseNoneFalse1715.1750
287917594105None1.1.1SupplyingheavygaugePVCconduitpipe.dia.mmthickconfirmingtoIS2509withsuitablesizebends,junctionboxes,adhesivepasteetc,andfixingusinginvertedwoodplugsincaseofRCCceilingandRCCwall/stonestructureorrawlplugsincaseofbrickwallsandcementplasteringthedamagedportionusingheavygauge saddles at an interval of 700mm using NF screws.Mtr69.069.030.0FalseNoneNoneFalseNoneFalse2070.00
287917694105None2.1.1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates work as per technical specificationsCum5947.25947.21.4FalseNoneNoneFalseNoneFalse8326.080
287917794105None5.2Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6948.96948.91.5FalseNoneNoneFalseNoneFalse10423.350
287917894105None5.3Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sandCum6515.256515.251.2FalseNoneNoneFalseNoneFalse7818.30
287917994105None5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6708.456708.452.7FalseNoneNoneFalseNoneFalse18112.8150
287918094105None1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum279.3279.33.6FalseNoneNoneFalseNoneFalse1005.480
287918194105None2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6601.356601.351.1FalseNoneNoneFalseNoneFalse7261.4850
287918294105None2.5.1Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cumSqm3960.813960.810.35FalseNoneNoneFalseNoneFalse1386.28350
287918394105None2.5.1Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cumSqm3300.683300.680.75FalseNoneNoneFalseNoneFalse2475.510
287918494105None2.11Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Tonne93929.8593929.850.1FalseNoneNoneFalseNoneFalse9392.9850
287918594105None6.7Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum8621.558621.554.14FalseNoneNoneFalseNoneFalse35693.2170
287918694105None8.6.1Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerin-charge.Sqm339.15339.1551.0FalseNoneNoneFalseNoneFalse17296.650
287918794105None8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm120.75120.7551.0FalseNoneNoneFalseNoneFalse6158.250
287918894105None13.2.1Providing and fixing brass bib cock of approved quality :Each300.3300.35.0FalseNoneNoneFalseNoneFalse1501.50
287918994105None1.6.1Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.Cum508.2508.255.0FalseNoneNoneFalseNoneFalse27951.00
287919094105None9.1.1Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0 HDPE Grade PE80-PN6.0, 63mm diaMtr198.45198.4555.0FalseNoneNoneFalseNoneFalse10914.750
17093472720000NoneNoneBuildingsDevelopment and Repairs of Electrification at GHPS School at RMSA at Baragur Village of Karatagi Taluka43321.0
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
287919194106None1.1.1Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc 75 x 75 x 65 mmNo106.0106.05.0FalseNoneNoneFalseNoneFalse530.00
287919294106None2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch boxNo285.0285.05.0FalseNoneNoneFalseNoneFalse1425.00
287919394106None2.2.1Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxNo394.0394.05.0FalseNoneNoneFalseNoneFalse1970.00
287919494106None2.2.2Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxNo555.0555.05.0FalseNoneNoneFalseNoneFalse2775.00
287919594106None3.8Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screwsSqm0.410.411500.0FalseNoneNoneFalseNoneFalse615.00
287919694106None3.1.2Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 WayEach147.0147.012.0FalseNoneNoneFalseNoneFalse1764.00
287919794106None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 48" Sweep (1200 mm) Regular modeNo1900.01900.06.0FalseNoneNoneFalseNoneFalse11400.00
287919894106None11.13Supplying and fixing of slim patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube.No361.0361.06.0FalseNoneNoneFalseNoneFalse2166.00
287919994106None13.1.1Supplying and Fixing of.mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires. Using 25mm dia G.I.PipeNo978.0978.01.0FalseNoneNoneFalseNoneFalse978.00
287920094106None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.5 mmm26.026.040.0FalseNoneNoneFalseNoneFalse1040.00
287920194106None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 2.5 mm2m42.042.040.0FalseNoneNoneFalseNoneFalse1680.00
287920294106None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 4 mm2m63.063.040.0FalseNoneNoneFalseNoneFalse2520.00
287920394106None1.1.1SupplyingheavygaugePVCconduitpipe.dia.mmthickconfirmingtoIS2509withsuitablesizebends,junctionboxes,adhesivepasteetc,andfixingusinginvertedwoodplugsincaseofRCCceilingandRCCwall/stonestructureorrawlplugsincaseofbrickwallsandcementplasteringthedamagedportionusingheavygauge saddles at an interval of 700mm using NF screws.Mtr69.069.040.0FalseNoneNoneFalseNoneFalse2760.00
287920494106NonePage No. 23Pre - Paid Energy Meter Single Phase, 5-30 Amps, 1.0 Accuracy Class with Key Pad Technology consumer interface unit along with pillfer proof boxNo7170.07170.01.0FalseNoneNoneFalseNoneFalse7170.00
287920594106None12.60.1Supplying&FixingChemicalearthlingforgrounding.Conduits,ICcut-outs&otherequipmentsbackfillcompoundwhichisnon-corrosive,thermallyconductive,potentialtopermissiblelimits,superiorFaultconductioncapacity,nontoxic,weatherresistance&capable of achieving ohmic value less than one ohmUsing 4ft. Copper bonded rod with backfill compoundNo4528.04528.01.0FalseNoneNoneFalseNoneFalse4528.00
17093472720000NoneNoneBuildingsRepairs of Building and Repairs of Electrification at School at Heror Village180572.25
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
287920694107None15.2Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2 l/per m2, having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 l/m2, and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification.Sqm773.85773.8564.0FalseNoneNoneFalseNoneFalse49526.40
287920794107None8.72.1Finishing walls with water proofing cement paint of required shade :Old work (one coats applied @ 2.20 kg/10 m²) over priming coat of primer applied @ 0.80 litrs/10 m² complete including cost of Priming coat including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm91.3591.35240.64FalseNoneNoneFalseNoneFalse21982.4640
287920894107None19.22Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction of Engineer-in-chargeSqm50.450.446.4FalseNoneNoneFalseNoneFalse2338.560
287920994107None2.1.1Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required t complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M7.5) Using 40 mm nominal size graded crushed coarse aggregatesCum5947.25947.24.64FalseNoneNoneFalseNoneFalse27595.0080
287921094107None9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grou ting the joints with white cement and matching pigments etc., complete. (Size of Tile 600x600 mm) Sqm1202.251202.2551.92FalseNoneNoneFalseNoneFalse62420.820
287921194107None1.1.1SupplyingheavygaugePVCconduitpipe.dia.mmthickconfirmingtoIS2509withsuitablesizebends,junctionboxes,adhesivepasteetc,andfixingusinginvertedwoodplugsincaseofRCCceilingandRCCwall/stonestructureorrawlplugsincaseofbrickwallsandcementplasteringthedamagedportionusingheavygauge saddles at an interval of 700mm using NF screws.Mtr69.069.020.0FalseNoneNoneFalseNoneFalse1380.00
287921294107None1.1.1Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc 75 x 75 x 65 mmNo106.0106.04.0FalseNoneNoneFalseNoneFalse424.00
287921394107None2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch boxNo285.0285.02.0FalseNoneNoneFalseNoneFalse570.00
287921494107None2.2.1Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxNo394.0394.02.0FalseNoneNoneFalseNoneFalse788.00
287921594107None2.2.2Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxNo555.0555.02.0FalseNoneNoneFalseNoneFalse1110.00
287921694107None3.8Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screwsSqm0.410.41600.0FalseNoneNoneFalseNoneFalse246.00
287921794107None3.1.2Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 WayEach147.0147.06.0FalseNoneNoneFalseNoneFalse882.00
287921894107None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 48" Sweep (1200 mm) Regular modeNo1900.01900.02.0FalseNoneNoneFalseNoneFalse3800.00
287921994107None11.13Supplying and fixing of slim patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube.No361.0361.01.0FalseNoneNoneFalseNoneFalse361.00
287922094107None12.60.1Supplying&FixingChemicalearthlingforgrounding.Conduits,ICcut-outs&otherequipmentsbackfillcompoundwhichisnon-corrosive,thermallyconductive,potentialtopermissiblelimits,superiorFaultconductioncapacity,nontoxic,weatherresistance&capable of achieving ohmic value less than one ohmUsing 4ft. Copper bonded rod with backfill compoundNo / m4528.04528.01.0FalseNoneNoneFalseNoneFalse4528.00
287922194107None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.5 mmm26.026.020.0FalseNoneNoneFalseNoneFalse520.00
287922294107None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 2.5 mm2m42.042.020.0FalseNoneNoneFalseNoneFalse840.00
287922394107None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 4 mm2m63.063.020.0FalseNoneNoneFalseNoneFalse1260.00
17093472720000NoneNoneBuildingsRepairs of Electrification at GHPS School at Siddapur Village12185.0
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
287922494108None3.1.2Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 WayEach147.0147.08.0FalseNoneNoneFalseNoneFalse1176.00
287922594108None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 48" Sweep (1200 mm) Regular modeNo1900.01900.04.0FalseNoneNoneFalseNoneFalse7600.00
287922694108None11.13Supplying and fixing of slim patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube.No361.0361.04.0FalseNoneNoneFalseNoneFalse1444.00
287922794108None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.5 mmm26.026.015.0FalseNoneNoneFalseNoneFalse390.00
287922894108None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 2.5 mm2m42.042.015.0FalseNoneNoneFalseNoneFalse630.00
287922994108None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 4 mm2m63.063.015.0FalseNoneNoneFalseNoneFalse945.00
17093472720000NoneNoneBuildingsRepairs of Building and Electrification at GHPS School at Chikkajanatakal Village349678.71
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
287923094109None1.1.1SupplyingheavygaugePVCconduitpipe.dia.mmthickconfirmingtoIS2509withsuitablesizebends,junctionboxes,adhesivepasteetc,andfixingusinginvertedwoodplugsincaseofRCCceilingandRCCwall/stonestructureorrawlplugsincaseofbrickwallsandcementplasteringthedamagedportionusingheavygauge saddles at an interval of 700mm using NF screws.No69.069.025.0FalseNoneNoneFalseNoneFalse1725.00
287923194109None1.1.1Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc 75 x 75 x 65 mmNo106.0106.04.0FalseNoneNoneFalseNoneFalse424.00
287923294109None2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch boxNo285.0285.02.0FalseNoneNoneFalseNoneFalse570.00
287923394109None2.2.1Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxNo394.0394.02.0FalseNoneNoneFalseNoneFalse788.00
287923494109None2.2.2Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxNo555.0555.02.0FalseNoneNoneFalseNoneFalse1110.00
287923594109None3.8Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screwsSqm0.410.41600.0FalseNoneNoneFalseNoneFalse246.00
287923694109None3.1.2Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 WayEach147.0147.04.0FalseNoneNoneFalseNoneFalse588.00
287923794109None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 48" Sweep (1200 mm) Regular modeNo1900.01900.02.0FalseNoneNoneFalseNoneFalse3800.00
287923894109None11.13Supplying and fixing of slim patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube.No361.0361.02.0FalseNoneNoneFalseNoneFalse722.00
287923994109None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.5 mmm26.026.013.0FalseNoneNoneFalseNoneFalse338.00
287924094109None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 2.5 mm2m42.042.013.0FalseNoneNoneFalseNoneFalse546.00
287924194109None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 4 mm2m63.063.013.0FalseNoneNoneFalseNoneFalse819.00
287924294109None12.60.1Supplying&FixingChemicalearthlingforgrounding.Conduits,ICcut-outs&otherequipmentsbackfillcompoundwhichisnon-corrosive,thermallyconductive,potentialtopermissiblelimits,superiorFaultconductioncapacity,nontoxic,weatherresistance&capable of achieving ohmic value less than one ohmUsing 4ft. Copper bonded rod with backfill compoundNo4528.04528.01.0FalseNoneNoneFalseNoneFalse4528.00
287924394109None15.23Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2 l/per m2, having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 l/m2, and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification.Sqm773.85773.85135.0FalseNoneNoneFalseNoneFalse104469.750
287924494109None8.72.1Finishing walls with water proofing cement paint of required shade :Old work (one coats applied @ 2.20 kg/10 m²) over priming coat of primer applied @ 0.80 litrs/10 m² complete including cost of Priming coat including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm91.3591.35442.2FalseNoneNoneFalseNoneFalse40394.970
287924594109None19.22Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction of Engineer-in-chargeCum50.450.498.4FalseNoneNoneFalseNoneFalse4959.360
287924694109None2.1.1Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required t complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M7.5) Using 40 mm nominal size graded crushed coarse aggregatesCum5947.25947.29.84FalseNoneNoneFalseNoneFalse58520.4480
287924794109None9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grou ting the joints with white cement and matching pigments etc., complete. (Size of Tile 600x600 mm)Sqm1202.251202.25104.08FalseNoneNoneFalseNoneFalse125130.180
17093472720000NoneNoneBuildingsRepairs of Building and Electrification at School at Hulihyder Village180804.56
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
287924894110None19.22Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction of Engineer-in-chargeCum50.450.496.0FalseNoneNoneFalseNoneFalse4838.40
287924994110None2.1.1Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required t complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M7.5) Using 40 mm nominal size graded crushed coarse aggregatesCum5947.25947.24.8FalseNoneNoneFalseNoneFalse28546.560
287925094110None9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grou ting the joints with white cement and matching pigments etc., complete. (Size of Tile 600x600 mm) Sqm1202.251202.25101.6FalseNoneNoneFalseNoneFalse122148.60
287925194110None1.1.1Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc 75 x 75 x 65 mmNo106.0106.04.0FalseNoneNoneFalseNoneFalse424.00
287925294110None2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch boxNo285.0285.04.0FalseNoneNoneFalseNoneFalse1140.00
287925394110None2.2.1Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxNo394.0394.04.0FalseNoneNoneFalseNoneFalse1576.00
287925494110None2.2.2Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxNo555.0555.04.0FalseNoneNoneFalseNoneFalse2220.00
287925594110None3.8Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screwsSqm0.410.41800.0FalseNoneNoneFalseNoneFalse328.00
287925694110None3.1.2Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 WayEach147.0147.08.0FalseNoneNoneFalseNoneFalse1176.00
287925794110None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 48" Sweep (1200 mm) Regular modeNo1900.01900.06.0FalseNoneNoneFalseNoneFalse11400.00
287925894110None11.13Supplying and fixing of slim patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube.No361.0361.04.0FalseNoneNoneFalseNoneFalse1444.00
287925994110None13.1.1Supplying and Fixing of.mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires. Using 25mm dia G.I.PipeNo978.0978.01.0FalseNoneNoneFalseNoneFalse978.00
287926094110None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.5 mmm26.026.035.0FalseNoneNoneFalseNoneFalse910.00
287926194110None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 2.5 mm2m42.042.035.0FalseNoneNoneFalseNoneFalse1470.00
287926294110None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 4 mm2m63.063.035.0FalseNoneNoneFalseNoneFalse2205.00
17093472720000NoneNoneBuildingsRepairs of School Building and Repairs of Electrification at Govt School at Kanakagiri Village180804.56
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
287926394111None19.22Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction of Engineer-in-chargeCum50.450.496.0FalseNoneNoneFalseNoneFalse4838.40
287926494111None2.1.1Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required t complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M7.5) Using 40 mm nominal size graded crushed coarse aggregates Cum5947.25947.24.8FalseNoneNoneFalseNoneFalse28546.560
287926594111None9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grou ting the joints with white cement and matching pigments etc., complete. (Size of Tile 600x600 mm)Sqm1202.251202.25101.6FalseNoneNoneFalseNoneFalse122148.60
287926694111None1.1.1Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc 75 x 75 x 65 mmNo106.0106.04.0FalseNoneNoneFalseNoneFalse424.00
287926794111None2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch boxNo285.0285.04.0FalseNoneNoneFalseNoneFalse1140.00
287926894111None2.2.1Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxNo394.0394.04.0FalseNoneNoneFalseNoneFalse1576.00
287926994111None2.2.2Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxNo555.0555.04.0FalseNoneNoneFalseNoneFalse2220.00
287927094111None3.8Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screwsSqm0.410.41800.0FalseNoneNoneFalseNoneFalse328.00
287927194111None3.1.2Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 WayEach147.0147.08.0FalseNoneNoneFalseNoneFalse1176.00
287927294111None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 48" Sweep (1200 mm) Regular modeNo1900.01900.06.0FalseNoneNoneFalseNoneFalse11400.00
287927394111None11.13Supplying and fixing of slim patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube.No361.0361.04.0FalseNoneNoneFalseNoneFalse1444.00
287927494111None13.1.1Supplying and Fixing of.mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires. Using 25mm dia G.I.PipeNo978.0978.01.0FalseNoneNoneFalseNoneFalse978.00
287927594111None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.5 mmm26.026.035.0FalseNoneNoneFalseNoneFalse910.00
287927694111None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 2.5 mm2m42.042.035.0FalseNoneNoneFalseNoneFalse1470.00
287927794111None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 4 mm2m63.063.035.0FalseNoneNoneFalseNoneFalse2205.00
17093472720000NoneNoneBuildingsConst of Water Tank Repairs of School Building and Elcetrification at Govt School at Navali Village348657.59
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
287927894112None1.4Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.Cum254.1254.16.75FalseNoneNoneFalseNoneFalse1715.1750
287927994112None2.1.1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates work as per technical specificationsCum5947.25947.21.4FalseNoneNoneFalseNoneFalse8326.080
287928094112None5.2Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6948.96948.91.5FalseNoneNoneFalseNoneFalse10423.350
287928194112None5.3Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sandCum6515.256515.251.2FalseNoneNoneFalseNoneFalse7818.30
287928294112None5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6708.456708.452.7FalseNoneNoneFalseNoneFalse18112.8150
287928394112None1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum279.3279.33.6FalseNoneNoneFalseNoneFalse1005.480
287928494112None2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6601.356601.351.1FalseNoneNoneFalseNoneFalse7261.4850
287928594112None2.5.1Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cumSqm3960.813960.810.35FalseNoneNoneFalseNoneFalse1386.28350
287928694112None2.5.1Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cumSqm3300.683300.680.75FalseNoneNoneFalseNoneFalse2475.510
287928794112None2.11Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Tonne93929.8593929.850.1FalseNoneNoneFalseNoneFalse9392.9850
287928894112None6.7Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum8621.558621.554.14FalseNoneNoneFalseNoneFalse35693.2170
287928994112None8.6.1Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerin-charge.Sqm339.15339.1551.0FalseNoneNoneFalseNoneFalse17296.650
287929094112None8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm120.75120.7551.0FalseNoneNoneFalseNoneFalse6158.250
287929194112None13.2.1Providing and fixing brass bib cock of approved quality :Each300.3300.35.0FalseNoneNoneFalseNoneFalse1501.50
287929294112None1.6.1Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.No508.2508.255.0FalseNoneNoneFalseNoneFalse27951.00
287929394112None9.1.1Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0 HDPE Grade PE80-PN6.0, 63mm diaMtr198.45198.4555.0FalseNoneNoneFalseNoneFalse10914.750
287929494112None8.33.1Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign atter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm165.9165.972.0FalseNoneNoneFalseNoneFalse11944.80
287929594112None19.22Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction of Engineer-in-chargeCum50.450.481.2FalseNoneNoneFalseNoneFalse4092.480
287929694112None2.1.1Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required t complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M7.5) Using 40 mm nominal size graded crushed coarse aggregates Cum5947.25947.28.12FalseNoneNoneFalseNoneFalse48291.2640
287929794112None9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grou ting the joints with white cement and matching pigments etc., complete. (Size of Tile 600x600 mm)Sqm1202.251202.2586.32FalseNoneNoneFalseNoneFalse103778.220
287929894112None1.1.1SupplyingheavygaugePVCconduitpipe.dia.mmthickconfirmingtoIS2509withsuitablesizebends,junctionboxes,adhesivepasteetc,andfixingusinginvertedwoodplugsincaseofRCCceilingandRCCwall/stonestructureorrawlplugsincaseofbrickwallsandcementplasteringthedamagedportionusingheavygauge saddles at an interval of 700mm using NF screws.Mtr69.069.030.0FalseNoneNoneFalseNoneFalse2070.00
287929994112None1.1.1Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc 75 x 75 x 65 mmNo106.0106.04.0FalseNoneNoneFalseNoneFalse424.00
287930094112None2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch boxNo285.0285.02.0FalseNoneNoneFalseNoneFalse570.00
287930194112None2.2.1Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxNo394.0394.02.0FalseNoneNoneFalseNoneFalse788.00
287930294112None2.2.2Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxNo555.0555.02.0FalseNoneNoneFalseNoneFalse1110.00
287930394112None3.8Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screwsSqm0.410.411000.0FalseNoneNoneFalseNoneFalse410.00
287930494112None3.1.2Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 WayEach147.0147.05.0FalseNoneNoneFalseNoneFalse735.00
287930594112None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 48" Sweep (1200 mm) Regular modeNo1900.01900.02.0FalseNoneNoneFalseNoneFalse3800.00
287930694112None11.13Supplying and fixing of slim patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube.No361.0361.02.0FalseNoneNoneFalseNoneFalse722.00
287930794112None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.5 mmm26.026.019.0FalseNoneNoneFalseNoneFalse494.00
287930894112None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 2.5 mm2m42.042.019.0FalseNoneNoneFalseNoneFalse798.00
287930994112None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 4 mm2m63.063.019.0FalseNoneNoneFalseNoneFalse1197.00
17093472720000NoneNoneBuildingsRepairs of Electrification at GHPS at RMSA at Marali Village42080.0
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
287931094113None1.1.1SupplyingheavygaugePVCconduitpipe.dia.mmthickconfirmingtoIS2509withsuitablesizebends,junctionboxes,adhesivepasteetc,andfixingusinginvertedwoodplugsincaseofRCCceilingandRCCwall/stonestructureorrawlplugsincaseofbrickwallsandcementplasteringthedamagedportionusingheavygauge saddles at an interval of 700mm using NF screws.Mtr69.069.030.0FalseNoneNoneFalseNoneFalse2070.00
287931194113None1.1.1Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc 75 x 75 x 65 mmNo106.0106.04.0FalseNoneNoneFalseNoneFalse424.00
287931294113None2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch boxNo285.0285.04.0FalseNoneNoneFalseNoneFalse1140.00
287931394113None2.2.1Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxNo394.0394.04.0FalseNoneNoneFalseNoneFalse1576.00
287931494113None2.2.2Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxNo555.0555.04.0FalseNoneNoneFalseNoneFalse2220.00
287931594113None3.8Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screwsSqm0.410.411500.0FalseNoneNoneFalseNoneFalse615.00
287931694113None3.1.2Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 WayEach147.0147.08.0FalseNoneNoneFalseNoneFalse1176.00
287931794113None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 48" Sweep (1200 mm) Regular modeNo1900.01900.06.0FalseNoneNoneFalseNoneFalse11400.00
287931894113None11.13Supplying and fixing of slim patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube.No361.0361.08.0FalseNoneNoneFalseNoneFalse2888.00
287931994113None13.1.1Supplying and Fixing of.mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires. Using 25mm dia G.I.PipeNo978.0978.01.0FalseNoneNoneFalseNoneFalse978.00
287932094113None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.5 mmm26.026.045.0FalseNoneNoneFalseNoneFalse1170.00
287932194113None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 2.5 mm2m42.042.045.0FalseNoneNoneFalseNoneFalse1890.00
287932294113None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 4 mm2m63.063.045.0FalseNoneNoneFalseNoneFalse2835.00
287932394113None12.60.1Supplying&FixingChemicalearthlingforgrounding.Conduits,ICcut-outs&otherequipmentsbackfillcompoundwhichisnon-corrosive,thermallyconductive,potentialtopermissiblelimits,superiorFaultconductioncapacity,nontoxic,weatherresistance&capable of achieving ohmic value less than one ohmUsing 4ft. Copper bonded rod with backfill compoundNo4528.04528.01.0FalseNoneNoneFalseNoneFalse4528.00
287932494113NoneP No 23Pre - Paid Energy Meter Single Phase, 5-30 Amps, 1.0 Accuracy Class with Key Pad Technology consumer interface unit along with pillfer proof boxNo7170.07170.01.0FalseNoneNoneFalseNoneFalse7170.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17093472730000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17093472730000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17093472730000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- KEY
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneList of existing commitments and ongoing worksCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- List of existing commitments and ongoing works
NoneNoneNoneNoneList of works for which tenders already submittedCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- List of works for which tenders already submitted
NoneNoneNoneNoneBanker Details for referenceCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Banker Details for reference
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- MACHINERY
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditors reports for the last five yearsCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneITR Filed Copy (Mentioning PAN)
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- tech documents
NoneNoneNoneNoneList of Financial Resources with CertificatesCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover Certificate 2018-19 to 2022-23 with UDIN No CompulsoryTrueTechnical Bid
Company Registration CertificateTrueTechnical Bid
Tenderer must Submit PAN & GST Certificate.TrueTechnical Bid
Accurate postal address and phone / cell phone numberTrueTechnical Bid
Work orders / commitments of ongoing works issued by an officer not below the rank of Executive EngineerTrueTechnical Bid
SIMILAR NATURE OF WORKDONE FIFTY PERCENTAGE 2018-19 TO 2022-23 FINANCIAL YEARTrueTechnical Bid
Line of Credit 30 PercentageTrueTechnical Bid
Quantity Wise Work Done of Last Five YearsTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone