2887319 | 94492 | None | code01 | BUILDING CIVIL WORK--Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING & SHUTTERING) RCC COLUMN --FIRST FLOOR | Cum | 13159.36 | 13159.36 | 6.52 | False | None | None | False | None | False | 85799.0272 | 0 |
2887320 | 94492 | None | code02 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING & SHUTTERING) RCC COLUMN --SECOND FLOOR | Cum | 13289.65 | 13289.65 | 18.16 | False | None | None | False | None | False | 241340.044 | 0 |
2887321 | 94492 | None | code03 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING & SHUTTERING) RCC COLUMN --TERRACE FLOOR | Cum | 13419.94 | 13419.94 | 1.58 | False | None | None | False | None | False | 21203.5052 | 0 |
2887322 | 94492 | None | code04 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING & SHUTTERING)-RCC COLUMN(DUMMY COLUMNS)-Terrace floor | Cum | 12192.28 | 12192.28 | 4.39 | False | None | None | False | None | False | 53524.1092 | 0 |
2887323 | 94492 | None | code05 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse
aggregates (RATE INCLUDING CENTERING & SHUTTERING)-RCC BEAM--FIRST FLOOR | Cum | 12385.28 | 12385.28 | 5.88 | False | None | None | False | None | False | 72825.4464 | 0 |
2887324 | 94492 | None | code06 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse
aggregates (RATE INCLUDING CENTERING & SHUTTERING)-RCC BEAM--SECOND FLOOR | Cum | 12507.91 | 12507.91 | 21.29 | False | None | None | False | None | False | 266293.4039 | 0 |
2887325 | 94492 | None | code07 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse
aggregates (RATE INCLUDING CENTERING & SHUTTERING)-RCC BEAM--TERRACE FLOOR | Cum | 12630.54 | 12630.54 | 0.9 | False | None | None | False | None | False | 11367.486 | 0 |
2887326 | 94492 | None | code08 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse
aggregates (RATE INCLUDING CENTERING & SHUTTERING) -RCC LINTEL--FIRST FLOOR | Cum | 12385.28 | 12385.28 | 2.77 | False | None | None | False | None | False | 34307.2256 | 0 |
2887327 | 94492 | None | code09 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse
aggregates (RATE INCLUDING CENTERING & SHUTTERING) -RCC LINTEL--SECOND FLOOR | Cum | 12507.91 | 12507.91 | 3.15 | False | None | None | False | None | False | 39399.9165 | 0 |
2887328 | 94492 | None | code10 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse
aggregates (RATE INCLUDING CENTERING & SHUTTERING) -RCC LINTEL--TERRACE FLOOR | Cum | 12630.54 | 12630.54 | 0.39 | False | None | None | False | None | False | 4925.9106 | 0 |
2887329 | 94492 | None | code11 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates-CILL CONCRETE-FIRST FLOOR | Cum | 7032.67 | 7032.67 | 1.39 | False | None | None | False | None | False | 9775.4113 | 0 |
2887330 | 94492 | None | code12 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates-CILL CONCRETE-SECOND FLOOR | Cum | 7102.3 | 7102.3 | 1.57 | False | None | None | False | None | False | 11150.611 | 0 |
2887331 | 94492 | None | code13 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates-CILL CONCRETE-TERRACE FLOOR | Cum | 7171.93 | 7171.93 | 31.45 | False | None | None | False | None | False | 225557.1985 | 0 |
2887332 | 94492 | None | code14 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING & SHUTTERING) RCC STAIRCASE--SECOND FLOOR | Cum | 11726.16 | 11726.16 | 3.71 | False | None | None | False | None | False | 43504.0536 | 0 |
2887333 | 94492 | None | code15 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications-FIRST FLOOR | Sqm | 1481.87 | 1481.87 | 259.59 | False | None | None | False | None | False | 384678.6333 | 0 |
2887334 | 94492 | None | code16 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specificationsSECOND FLOOR | Sqm | 1496.54 | 1496.54 | 718.87 | False | None | None | False | None | False | 1075817.7098 | 0 |
2887335 | 94492 | None | code17 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications-TERRACE FLOOR | Sqm | 1511.22 | 1511.22 | 60.42 | False | None | None | False | None | False | 91307.9124 | 0 |
2887336 | 94492 | None | code18 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.-SECOND FLOOR | Sqm | 1406.29 | 1406.29 | 81.0 | False | None | None | False | None | False | 113909.49 | 0 |
2887337 | 94492 | None | code19 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.-TERRACE FLOOR | Sqm | 1420.08 | 1420.08 | 48.0 | False | None | None | False | None | False | 68163.84 | 0 |
2887338 | 94492 | None | code20 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.SECOND FLOOR | Sqm | 1261.21 | 1261.21 | 25.2 | False | None | None | False | None | False | 31782.492 | 0 |
2887339 | 94492 | None | code21 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-(RATE INCLUDING CENTERING & SHUTTERING)-RCC SLAB-FIRST FLOOR | Cum | 11611.2 | 11611.2 | 38.34 | False | None | None | False | None | False | 445173.408 | 0 |
2887340 | 94492 | None | code22 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-(RATE INCLUDING CENTERING & SHUTTERING)-RCC SLAB SECOND FLOOR | Cum | 11726.16 | 11726.16 | 62.5 | False | None | None | False | None | False | 732885.0 | 0 |
2887341 | 94492 | None | code23 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-(RATE INCLUDING CENTERING & SHUTTERING)-RCC SLAB TERRACE FLOOR | Cum | 11841.13 | 11841.13 | 5.1 | False | None | None | False | None | False | 60389.763 | 0 |
2887342 | 94492 | None | code24 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-(RATE INCLUDING CENTERING & SHUTTERING)-RCC CHAJJA-FIRST FLOOR | Cum | 11224.16 | 11224.16 | 1.4 | False | None | None | False | None | False | 15713.824 | 0 |
2887343 | 94492 | None | code25 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-(RATE INCLUDING CENTERING & SHUTTERING)-RCC CHAJJA-SECOND FLOOR | Cum | 11335.29 | 11335.29 | 5.0 | False | None | None | False | None | False | 56676.45 | 0 |
2887344 | 94492 | None | code26 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-(RATE INCLUDING CENTERING & SHUTTERING)-RCC CHAJJA-TERRACE FLOOR | Cum | 11446.42 | 11446.42 | 0.18 | False | None | None | False | None | False | 2060.3556 | 0 |
2887345 | 94492 | None | code27 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a)Buildings | Tonne | 101193.76 | 101193.76 | 19.1 | False | None | None | False | None | False | 1932800.816 | 0 |
2887346 | 94492 | None | code28 | Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications-FIRST FLOOR | Cum | 112667.52 | 112667.52 | 0.55 | False | None | None | False | None | False | 61967.136 | 0 |
2887347 | 94492 | None | code29 | Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications-SECOND FLOOR | Cum | 113794.2 | 113794.2 | 1.51 | False | None | None | False | None | False | 171829.242 | 0 |
2887348 | 94492 | None | code30 | Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications-TERRACE FLOOR | Cum | 114898.56 | 114898.56 | 0.05 | False | None | None | False | None | False | 5744.928 | 0 |
2887349 | 94492 | None | code31 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)-FIRST FLOOR | Sqm | 7617.5 | 7617.5 | 18.0 | False | None | None | False | None | False | 137115.0 | 0 |
2887350 | 94492 | None | code32 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)-SECOND FLOOR | Sqm | 7693.68 | 7693.68 | 33.47 | False | None | None | False | None | False | 257507.4696 | 0 |
2887351 | 94492 | None | code33 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)-TERRACE FLOOR | Sqm | 7692.92 | 7692.92 | 2.43 | False | None | None | False | None | False | 18693.7956 | 0 |
2887352 | 94492 | None | code34 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)-FIRST FLOOR | Sqm | 6469.33 | 6469.33 | 8.64 | False | None | None | False | None | False | 55895.0112 | 0 |
2887353 | 94492 | None | code35 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)-SECOND FLOOR | Sqm | 6534.03 | 6534.03 | 16.56 | False | None | None | False | None | False | 108203.5368 | 0 |
2887354 | 94492 | None | code36 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-35 mm thick both side commercial-FIRST FLOOR | Sqm | 3757.85 | 3757.85 | 12.9 | False | None | None | False | None | False | 48476.265 | 0 |
2887355 | 94492 | None | code37 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-35 mm thick both side commercial-SECOND FLOOR | Sqm | 3795.42 | 3795.42 | 41.39 | False | None | None | False | None | False | 157092.4338 | 0 |
2887356 | 94492 | None | code38 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-35 mm thick both side commercial-TERRACE FLOOR | Sqm | 3795.05 | 3795.05 | 2.15 | False | None | None | False | None | False | 8159.3575 | 0 |
2887357 | 94492 | None | code39 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding-FIRST FLOOR | Kg | 190.04 | 190.04 | 426.0284 | False | None | None | False | None | False | 80962.437136 | 0 |
2887358 | 94492 | None | code40 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding-SECOND FLOOR | Kg | 191.94 | 191.94 | 800.4 | False | None | None | False | None | False | 153628.776 | 0 |
2887359 | 94492 | None | code41 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding-TERRACE FLOOR | Kg | 191.92 | 191.92 | 43.74 | False | None | None | False | None | False | 8394.5808 | 0 |
2887360 | 94492 | None | code42 | Providing 12 mm cement plaster with Cement mortar 1:3 (1cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete-FIRST FLOOR | Sqm | 365.38 | 365.38 | 207.5 | False | None | None | False | None | False | 75816.35 | 0 |
2887361 | 94492 | None | code43 | Providing 12 mm cement plaster with Cement mortar 1:3 (1cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing completeSECOND FLOOR | Sqm | 369.03 | 369.03 | 456.46 | False | None | None | False | None | False | 168447.4338 | 0 |
2887362 | 94492 | None | code44 | Providing 12 mm cement plaster with Cement mortar 1:3 (1cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete-TERRACE FLOOR | Sqm | 369.0 | 369.0 | 33.97 | False | None | None | False | None | False | 12534.93 | 0 |
2887363 | 94492 | None | code45 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.-FIRST FLOOR | Sqm | 414.02 | 414.02 | 482.69 | False | None | None | False | None | False | 199843.3138 | 0 |
2887364 | 94492 | None | code46 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.-SECOND FLOOR | Sqm | 418.12 | 418.12 | 934.76 | False | None | None | False | None | False | 390841.8512 | 0 |
2887365 | 94492 | None | code47 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.-TERRACE FLOOR | Sqm | 418.12 | 418.12 | 49.14 | False | None | None | False | None | False | 20546.4168 | 0 |
2887366 | 94492 | None | code48 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.-SECOND FLOOR | Sqm | 337.04 | 337.04 | 259.29 | False | None | None | False | None | False | 87391.1016 | 0 |
2887367 | 94492 | None | code49 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.-Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer in-Charge.-FIRST FLOOR | Sqm | 507.91 | 507.91 | 292.5 | False | None | None | False | None | False | 148563.675 | 0 |
2887368 | 94492 | None | code50 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.-Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer in-Charge.-SECOND FLOOR | Sqm | 512.94 | 512.94 | 587.25 | False | None | None | False | None | False | 301224.015 | 0 |
2887369 | 94492 | None | code51 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.-Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer in-Charge.-TERRACE FLOOR | Sqm | 517.97 | 517.97 | 302.4 | False | None | None | False | None | False | 156634.128 | 0 |
2887370 | 94492 | None | code52 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.-Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer in-Charge.-OPEN TERRACE PLASTERING | Sqm | 517.97 | 517.97 | 416.69 | False | None | None | False | None | False | 215832.9193 | 0 |
2887371 | 94492 | None | code53 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.-SECOND FLOOR | Cum | 2304.22 | 2304.22 | 15.74 | False | None | None | False | None | False | 36268.4228 | 0 |
2887372 | 94492 | None | code54 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. | Sqm | 636.16 | 636.16 | 25.0 | False | None | None | False | None | False | 15904.0 | 0 |
2887373 | 94492 | None | code55 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top cover Crimp curve | Sqm | 476.0 | 476.0 | 3.0 | False | None | None | False | None | False | 1428.0 | 0 |
2887374 | 94492 | None | code56 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top cover Gutter (600 mm over all girth) | m | 1202.88 | 1202.88 | 20.0 | False | None | None | False | None | False | 24057.6 | 0 |
2887375 | 94492 | None | code57 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester Ridges plain (500 - 600mm) | m | 505.12 | 505.12 | 10.0 | False | None | None | False | None | False | 5051.2 | 0 |
2887376 | 94492 | None | code58 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 164.64 | 164.64 | 125.0 | False | None | None | False | None | False | 20580.0 | 0 |
2887377 | 94492 | None | code59 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent.-FIRST FLOOR | Sqm | 3226.18 | 3226.18 | 71.2 | False | None | None | False | None | False | 229704.016 | 0 |
2887378 | 94492 | None | code60 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent.SECOND FLOOR | Sqm | 3258.44 | 3258.44 | 156.06 | False | None | None | False | None | False | 508512.1464 | 0 |
2887379 | 94492 | None | code61 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.-- Size of Tile 800x800 mm-FIRST FLOOR | Sqm | 1421.92 | 1421.92 | 114.9 | False | None | None | False | None | False | 163378.608 | 0 |
2887380 | 94492 | None | code62 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.-- Size of Tile 800x800 mm-SECONDFLOOR | Sqm | 1436.14 | 1436.14 | 196.31 | False | None | None | False | None | False | 281928.6434 | 0 |
2887381 | 94492 | None | code63 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete-SECOND FLOOR | Sqm | 1015.59 | 1015.59 | 62.42 | False | None | None | False | None | False | 63393.1278 | 0 |
2887382 | 94492 | None | code64 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete.-SECOND FLOOR | Sqm | 1263.49 | 1263.49 | 259.29 | False | None | None | False | None | False | 327610.3221 | 0 |
2887383 | 94492 | None | code65 | Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications-SECOND FLOOR | Sqm | 1884.96 | 1884.96 | 12.9 | False | None | None | False | None | False | 24315.984 | 0 |
2887384 | 94492 | None | code66 | Providing and laying flooring and steps machine cut granite slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with ce ment mortar 1:3 over existing cement concrete bed , including cost of materials, mortar labour, curing complete as per specifications.SECOND FLOOR | Sqm | 4888.81 | 4888.81 | 6.72 | False | None | None | False | None | False | 32852.8032 | 0 |
2887385 | 94492 | None | code67 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.-FIRST FLOOR | Sqm | 113.12 | 113.12 | 690.19 | False | None | None | False | None | False | 78074.2928 | 0 |
2887386 | 94492 | None | code68 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.-SECOND FLOOR | Sqm | 114.25 | 114.25 | 1391.22 | False | None | None | False | None | False | 158946.885 | 0 |
2887387 | 94492 | None | code69 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.-TERRACE FLOOR | Sqm | 114.24 | 114.24 | 69.02 | False | None | None | False | None | False | 7884.8448 | 0 |
2887388 | 94492 | None | code70 | Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.-FIRST FLOOR | Sqm | 178.73 | 178.73 | 207.5 | False | None | None | False | None | False | 37086.475 | 0 |
2887389 | 94492 | None | code71 | Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.SECOND FLOOR | Sqm | 180.52 | 180.52 | 456.46 | False | None | None | False | None | False | 82400.1592 | 0 |
2887390 | 94492 | None | code72 | Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.-TERRACE FLOOR | Sqm | 180.5 | 180.5 | 20.75 | False | None | None | False | None | False | 3745.375 | 0 |
2887391 | 94492 | None | code73 | Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.-FIRST FLOOR | Sqm | 178.73 | 178.73 | 482.69 | False | None | None | False | None | False | 86271.1837 | 0 |
2887392 | 94492 | None | code74 | Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.-SECOND FLOOR | Sqm | 180.52 | 180.52 | 934.76 | False | None | None | False | None | False | 168742.8752 | 0 |
2887393 | 94492 | None | code75 | Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.-TERRACE FLOOR | Sqm | 180.5 | 180.5 | 48.27 | False | None | None | False | None | False | 8712.735 | 0 |
2887394 | 94492 | None | code76 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.-FIRST FLOOR | Sqm | 196.83 | 196.83 | 292.5 | False | None | None | False | None | False | 57572.775 | 0 |
2887395 | 94492 | None | code77 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.-SECOND FLOOR | Sqm | 198.8 | 198.8 | 587.25 | False | None | None | False | None | False | 116745.3 | 0 |
2887396 | 94492 | None | code78 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.-TERRACE FLOOR | Sqm | 198.78 | 198.78 | 29.25 | False | None | None | False | None | False | 5814.315 | 0 |
2887397 | 94492 | None | code79 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.-FIRST FLOOR | Sqm | 188.91 | 188.91 | 26.64 | False | None | None | False | None | False | 5032.5624 | 0 |
2887398 | 94492 | None | code80 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.-SECOND FLOOR | Sqm | 190.8 | 190.8 | 50.03 | False | None | None | False | None | False | 9545.724 | 0 |
2887399 | 94492 | None | code81 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.-TERRACE FLOOR | Sqm | 190.78 | 190.78 | 2.66 | False | None | None | False | None | False | 507.4748 | 0 |
2887400 | 94492 | None | code82 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge.-FIRST FLOOR | Sqm | 63.35 | 63.35 | 27.09 | False | None | None | False | None | False | 1716.1515 | 0 |
2887401 | 94492 | None | code83 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge.-SECOND FLOOR | Sqm | 63.98 | 63.98 | 49.67 | False | None | None | False | None | False | 3177.8866 | 0 |
2887402 | 94492 | None | code84 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge.-TERRACE FLOOR | Sqm | 63.97 | 63.97 | 2.71 | False | None | None | False | None | False | 173.3587 | 0 |
2887403 | 94492 | None | code85 | Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.-FIRST FLOOR | Sqm | 152.71 | 152.71 | 27.09 | False | None | None | False | None | False | 4136.9139 | 0 |
2887404 | 94492 | None | code86 | Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.-SECOND FLOOR | Sqm | 154.24 | 154.24 | 49.67 | False | None | None | False | None | False | 7661.1008 | 0 |
2887405 | 94492 | None | code87 | Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.-TERRACE FLOOR | Sqm | 154.22 | 154.22 | 2.71 | False | None | None | False | None | False | 417.9362 | 0 |
2887406 | 94492 | None | code88 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges
of machinery complete as per specifications and as per directions of the Engineer-in-Charge.-FIRST FLOOR | Kg | 639.13 | 639.13 | 43.2 | False | None | None | False | None | False | 27610.416 | 0 |
2887407 | 94492 | None | code89 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges
of machinery complete as per specifications and as per directions of the Engineer-in-Charge.-SECOND FLOOR | Kg | 645.52 | 645.52 | 116.8 | False | None | None | False | None | False | 75396.736 | 0 |
2887408 | 94492 | None | code90 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:-PVC pipes 110mm dia., 6 kg/sqcm | m | 460.32 | 460.32 | 60.0 | False | None | None | False | None | False | 27619.2 | 0 |
2887409 | 94492 | None | code91 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.(Polyurethane based Single Component for New Surface)-SECOND FLOOR | Sqm | 933.34 | 933.34 | 72.0 | False | None | None | False | None | False | 67200.48 | 0 |
2887410 | 94492 | None | code92 | Providing and fixing bright finished brass single acting spring hinges with necessary brass screws etc. complete : 150 mm | Each | 677.74 | 677.74 | 56.0 | False | None | None | False | None | False | 37953.44 | 0 |
2887411 | 94492 | None | code93 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete | Nos | 1083.56 | 1083.56 | 14.0 | False | None | None | False | None | False | 15169.84 | 0 |
2887412 | 94492 | None | code94 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete | Nos | 244.11 | 244.11 | 28.0 | False | None | None | False | None | False | 6835.08 | 0 |
2887413 | 94492 | None | code95 | roviding and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete | Nos | 133.9 | 133.9 | 12.0 | False | None | None | False | None | False | 1606.8 | 0 |
2887414 | 94492 | None | code96 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms | Nos | 56.65 | 56.65 | 28.0 | False | None | None | False | None | False | 1586.2 | 0 |
2887415 | 94492 | None | code97 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90mm | Nos | 105.06 | 105.06 | 48.0 | False | None | None | False | None | False | 5042.88 | 0 |
2887416 | 94492 | None | code98 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete 250x10mm | Nos | 448.05 | 448.05 | 14.0 | False | None | None | False | None | False | 6272.7 | 0 |
2887417 | 94492 | None | code99 | PLUMBING AND SANITARY-Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required-White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests | Nos | 5470.08 | 5470.08 | 1.0 | False | None | None | False | None | False | 5470.08 | 0 |
2887418 | 94492 | None | code100 | Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing
& fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete | Nos | 12570.88 | 12570.88 | 5.0 | False | None | None | False | None | False | 62854.4 | 0 |
2887419 | 94492 | None | code101 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer | Nos | 4615.52 | 4615.52 | 8.0 | False | None | None | False | None | False | 36924.16 | 0 |
2887420 | 94492 | None | code102 | Providing and fixing 100 mm sand cast Iron grating for gully trap. | Nos | 52.64 | 52.64 | 20.0 | False | None | None | False | None | False | 1052.8 | 0 |
2887421 | 94492 | None | code103 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. | Nos | 812.0 | 812.0 | 15.0 | False | None | None | False | None | False | 12180.0 | 0 |
2887422 | 94492 | None | code104 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 g. | Nos | 947.52 | 947.52 | 20.0 | False | None | None | False | None | False | 18950.4 | 0 |
2887423 | 94492 | None | code105 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end)-25 mm nominal bore | Nos | 1098.0 | 1098.0 | 1.0 | False | None | None | False | None | False | 1098.0 | 0 |
2887424 | 94492 | None | code106 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end)-32 mm nominal bore | Nos | 1196.0 | 1196.0 | 1.0 | False | None | None | False | None | False | 1196.0 | 0 |
2887425 | 94492 | None | code107 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end)-40 mm nominal bore | Nos | 1404.0 | 1404.0 | 1.0 | False | None | None | False | None | False | 1404.0 | 0 |
2887426 | 94492 | None | code108 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end)-50 mm nominal bore | Nos | 1710.0 | 1710.0 | 2.0 | False | None | None | False | None | False | 3420.0 | 0 |
2887427 | 94492 | None | code109 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end)-65 mm nominal bore | Nos | 2822.0 | 2822.0 | 2.0 | False | None | None | False | None | False | 5644.0 | 0 |
2887428 | 94492 | None | code110 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end)-80 mm nominal bore | Nos | 4154.0 | 4154.0 | 2.0 | False | None | None | False | None | False | 8308.0 | 0 |
2887429 | 94492 | None | code111 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. | Nos | 1366.4 | 1366.4 | 8.0 | False | None | None | False | None | False | 10931.2 | 0 |
2887430 | 94492 | None | code112 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. | Nos | 555.52 | 555.52 | 8.0 | False | None | None | False | None | False | 4444.16 | 0 |
2887431 | 94492 | None | code113 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:-PVC pipes 160mm dia., 6 kg/sqcm & class 3- | m | 692.16 | 692.16 | 20.0 | False | None | None | False | None | False | 13843.2 | 0 |
2887432 | 94492 | None | code114 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:-PVC pipes 110mm dia., 6 kg/sqcm & class 3 | m | 460.32 | 460.32 | 30.0 | False | None | None | False | None | False | 13809.6 | 0 |
2887433 | 94492 | None | code115 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:-PVC pipes 90mm dia., 6 kg/sqcm & class 3 | m | 329.28 | 329.28 | 45.0 | False | None | None | False | None | False | 14817.6 | 0 |
2887434 | 94492 | None | code116 | Providing and fixing Chorinated Poly Venly Cloride (CPVC) pipes conforming to IS15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr. spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (concealed work including cutting chases and good the walls etc), For 50 mm dia-Including gyser and solar line | m | 874.72 | 874.72 | 65.0 | False | None | None | False | None | False | 56856.8 | 0 |
2887435 | 94492 | None | code117 | Providing and fixing Chorinated Poly Venly Cloride (CPVC) pipes conforming to IS15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr. spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (concealed work including cutting chases and good the walls etc), For 32 mm dia-Including gyser and solar line | m | 448.0 | 448.0 | 65.0 | False | None | None | False | None | False | 29120.0 | 0 |
2887436 | 94492 | None | code118 | Providing and fixing Chorinated Poly Venly Cloride (CPVC) pipes conforming to IS15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr. spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (concealed work including cutting chases and good the walls etc), For 25 mm dia | m | 356.16 | 356.16 | 65.0 | False | None | None | False | None | False | 23150.4 | 0 |
2887437 | 94492 | None | code119 | Providing and fixing Chorinated Poly Venly Cloride (CPVC) pipes conforming to IS15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr. spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (concealed work including cutting chases and good the walls etc), For 20 mm dia | m | 271.04 | 271.04 | 45.0 | False | None | None | False | None | False | 12196.8 | 0 |
2887438 | 94492 | None | code120 | Providing PVC-U INDIVIDUAL U.G.D House service connection (which shall be laid from inside the customer property ) which includes: a) Supply of PVC-U pipe (b) providing and fixing of 315 mm dia the PE Inspection chambres with lid consisting of inlet & outlet arrangements with base, riser of min. 0.42 m depth which includes earth work, fixing in CC-1:2:4 with appurtenances., complete. (c) civil works like Earthwork excavation for the pipeline trenches for laying of PVC-U pipes for the house connections in all types of soils , disintegrated rock,soft rock, hard rock, including cutting of any road using , crossing drains, compound, Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, c.c. wood work, steel work, including T & P and scaffolding wherever necessary sorting the dismantled material, disposal of unserviceable and stacking the serviceable material with all lifts and lead , restoring the damaged portions inside or outside the property premises, refilling the portions of trenches that are dug open including linking to existing sewer network with appurtenances. complete.Supply and fixing of SFRC machinhole cover (Medium Duty) made as per IS to suit existing damaged machinhole cover after removing the debries from inside and outside the existing machinhole etc. with all lead
and lifts. 110 mm dia | Nos | 9110.08 | 9110.08 | 1.0 | False | None | None | False | None | False | 9110.08 | 0 |
2887439 | 94492 | None | code121 | KSRB 13-11 : Providing and placing on terrace, polyethylene water storage tanks as per IS 12701 : 1996 with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flow pipes, including cost of all materials, labour, transport charges, HOM and testing complete as per specifications.
Specification No.KBS 13.22 | l | 10.08 | 10.08 | 2000.0 | False | None | None | False | None | False | 20160.0 | 0 |
2887440 | 94492 | None | code122 | Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3 density Rock wool insulation with 22SWG Aluminium cladding.-200L | Each | 49934.4 | 49934.4 | 1.0 | False | None | None | False | None | False | 49934.4 | 0 |
2887441 | 94492 | None | code123 | INTERNAL ELECTRIFICATION-Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. and running before Concreting the Slab. The Conduit should be tied to the reenforcement Rods by using binding wires and the unused ways of Junction boxes should be covered using PVC End enclosures .run with 18 SWG GI finish wire wherever it is necessory-19/20mm Dia 2mm Thick | m | 67.98 | 67.98 | 320.0 | False | None | None | False | None | False | 21753.6 | 0 |
2887442 | 94492 | None | code124 | Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. and running before Concreting the Slab. The Conduit should be tied to the reenforcement Rods by using binding wires and the unused ways of Junction boxes should be covered using PVC End enclosures .run with 18 SWG GI finish wire wherever it is necessory25mm dia 2mm Thick | m | 80.34 | 80.34 | 360.0 | False | None | None | False | None | False | 28922.4 | 0 |
2887443 | 94492 | None | code125 | Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. by groove cutting in the wall and fixing by bracing U or J hooks and plastering upto wall surface and .run with 18 SWG GI finish wire wherever it is necessory-19/20mm Dia 2mm Thick | m | 70.04 | 70.04 | 221.0 | False | None | None | False | None | False | 15478.84 | 0 |
2887444 | 94492 | None | code126 | Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. by groove cutting in the wall and fixing by bracing U or J hooks and plastering upto wall surface and .run with 18 SWG GI finish wire wherever it is necessory-25mm dia 2mm Thick | m | 81.37 | 81.37 | 231.0 | False | None | None | False | None | False | 18796.47 | 0 |
2887445 | 94492 | None | code127 | Supplying and fixing PVC/ Metal Conduit Deep Junction Boxes-19/20 mm Deep Junction Box | Each | 50.47 | 50.47 | 110.0 | False | None | None | False | None | False | 5551.7 | 0 |
2887446 | 94492 | None | code128 | Supplying and fixing PVC/ Metal Conduit Deep Junction Boxes-25 mm Deep Junction Box | Each | 57.68 | 57.68 | 40.0 | False | None | None | False | None | False | 2307.2 | 0 |
2887447 | 94492 | None | code129 | Supplying and fixing PVC Casing and capping on the wall or ceiling using materials like bend , screws at an interval 0f 300 mm etc-20 mm | m | 28.84 | 28.84 | 68.0 | False | None | None | False | None | False | 1961.12 | 0 |
2887448 | 94492 | None | code130 | Supplying and fixing PVC Casing and capping on the wall or ceiling using materials like bend , screws at an interval 0f 300 mm etc-25 mm | m | 36.05 | 36.05 | 58.0 | False | None | None | False | None | False | 2090.9 | 0 |
2887449 | 94492 | None | code131 | Supplying PVC /GI flexible conduit pipe …. Mm dia fixing on surface cover inverted tapared wodden plugs or phill plugs or rawl plugs and clamped using heavy guage saddles in an interval of 300 mm using NF screws and on the eaiter end of the pipe terminated properly-20 mm | m | 19.57 | 19.57 | 65.0 | False | None | None | False | None | False | 1272.05 | 0 |
2887450 | 94492 | None | code132 | Supplying PVC /GI flexible conduit pipe …. Mm dia fixing on surface cover inverted tapared wodden plugs or phill plugs or rawl plugs and clamped using heavy guage saddles in an interval of 300 mm using NF screws and on the eaiter end of the pipe terminated properly-20 mm 25 mm | m | 22.66 | 22.66 | 45.0 | False | None | None | False | None | False | 1019.7 | 0 |
2887451 | 94492 | None | code133 | Supply & Fixing of Metal fan box with round Hook | Each | 164.8 | 164.8 | 30.0 | False | None | None | False | None | False | 4944.0 | 0 |
2887452 | 94492 | None | code134 | Supplying and wiring adopting loop system in existing PVC conduit/casing capping, using copper FRLS PVC insulated multi strand 2 x 1.5 sq.mm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block complete for each outlet.-Short point upto 3 Mtd. From Tapping point to outlet via switch box. | Point | 277.07 | 277.07 | 20.0 | False | None | None | False | None | False | 5541.4 | 0 |
2887453 | 94492 | None | code135 | Supplying and wiring adopting loop system in existing PVC conduit/casing capping, using copper FRLS PVC insulated multi strand 2 x 1.5 sq.mm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block complete for each outlet.-Medium point above 3 Mts upto 6 Mts. From tapping point to outlet via switch box. | Point | 390.37 | 390.37 | 30.0 | False | None | None | False | None | False | 11711.1 | 0 |
2887454 | 94492 | None | code136 | Supplying and wiring adopting loop system in existing PVC conduit/casing capping, using copper FRLS PVC insulated multi strand 2 x 1.5 sq.mm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block complete for each outlet.-Long point above 6 Mts. Upto 10 Mts. From tapping of point to outlet via switch box. | Point | 571.65 | 571.65 | 20.0 | False | None | None | False | None | False | 11433.0 | 0 |
2887455 | 94492 | None | code137 | Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring-1.5 Sqmm | m | 26.78 | 26.78 | 103.0 | False | None | None | False | None | False | 2758.34 | 0 |
2887456 | 94492 | None | code138 | Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring-2.5Sqmm | m | 43.26 | 43.26 | 250.0 | False | None | None | False | None | False | 10815.0 | 0 |
2887457 | 94492 | None | code139 | Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring-4Sqmm | m | 64.89 | 64.89 | 220.0 | False | None | None | False | None | False | 14275.8 | 0 |
2887458 | 94492 | None | code140 | Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring-6 sqmm | m | 94.76 | 94.76 | 160.0 | False | None | None | False | None | False | 15161.6 | 0 |
2887459 | 94492 | None | code141 | Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring-10Sqmm | m | 172.01 | 172.01 | 95.0 | False | None | None | False | None | False | 16340.95 | 0 |
2887460 | 94492 | None | code142 | Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall-1-3 way | Each | 142.14 | 142.14 | 52.0 | False | None | None | False | None | False | 7391.28 | 0 |
2887461 | 94492 | None | code143 | Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall-4-5 way | Each | 163.77 | 163.77 | 27.0 | False | None | None | False | None | False | 4421.79 | 0 |
2887462 | 94492 | None | code144 | Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall-6 way | Each | 182.31 | 182.31 | 49.0 | False | None | None | False | None | False | 8933.19 | 0 |
2887463 | 94492 | None | code145 | Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall-8 way | Each | 226.6 | 226.6 | 44.0 | False | None | None | False | None | False | 9970.4 | 0 |
2887464 | 94492 | None | code146 | Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall-12 way | Each | 268.83 | 268.83 | 27.0 | False | None | None | False | None | False | 7258.41 | 0 |
2887465 | 94492 | None | code147 | Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box-1-3 way | Each | 141.11 | 141.11 | 35.0 | False | None | None | False | None | False | 4938.85 | 0 |
2887466 | 94492 | None | code148 | Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box-4-5 way | Each | 165.83 | 165.83 | 41.0 | False | None | None | False | None | False | 6799.03 | 0 |
2887467 | 94492 | None | code149 | Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box-6 way | Each | 180.25 | 180.25 | 65.0 | False | None | None | False | None | False | 11716.25 | 0 |
2887468 | 94492 | None | code150 | Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box-8 way | Each | 241.02 | 241.02 | 35.0 | False | None | None | False | None | False | 8435.7 | 0 |
2887469 | 94492 | None | code151 | Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box-12way | Each | 292.52 | 292.52 | 25.0 | False | None | None | False | None | False | 7313.0 | 0 |
2887470 | 94492 | None | code152 | Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate -6 Amp one way | Each | 105.06 | 105.06 | 135.0 | False | None | None | False | None | False | 14183.1 | 0 |
2887471 | 94492 | None | code153 | Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate -6 Amps 2 way | Each | 170.98 | 170.98 | 8.0 | False | None | None | False | None | False | 1367.84 | 0 |
2887472 | 94492 | None | code154 | Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate -6 Amps 3 way socket | Each | 176.13 | 176.13 | 102.0 | False | None | None | False | None | False | 17965.26 | 0 |
2887473 | 94492 | None | code155 | Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate -Stepped Fan Regulator | Each | 367.71 | 367.71 | 37.0 | False | None | None | False | None | False | 13605.27 | 0 |
2887474 | 94492 | None | code156 | Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate -16 Amps 1 way switch | Each | 185.4 | 185.4 | 35.0 | False | None | None | False | None | False | 6489.0 | 0 |
2887475 | 94492 | None | code157 | Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate -6/16 Amps universal socket | Each | 243.08 | 243.08 | 37.0 | False | None | None | False | None | False | 8993.96 | 0 |
2887476 | 94492 | None | code158 | Supply and fixing of -Led Light Fixture 2 feet - 9/10 W | Each | 567.53 | 567.53 | 15.0 | False | None | None | False | None | False | 8512.95 | 0 |
2887477 | 94492 | None | code159 | Supply and fixing of -Led Light Fixture 4 feet - 20/22 W | Each | 710.7 | 710.7 | 25.0 | False | None | None | False | None | False | 17767.5 | 0 |
2887478 | 94492 | None | code160 | Supply and fixing of -7 Watt LED Bulb | Each | 153.47 | 153.47 | 15.0 | False | None | None | False | None | False | 2302.05 | 0 |
2887479 | 94492 | None | code161 | Supply and fixing of -Surface Light LED square or round down light 10 -12 W | Each | 911.55 | 911.55 | 10.0 | False | None | None | False | None | False | 9115.5 | 0 |
2887480 | 94492 | None | code162 | Supply and fixing of -Led Streetlight 25 Watt | Each | 2497.75 | 2497.75 | 2.0 | False | None | None | False | None | False | 4995.5 | 0 |
2887481 | 94492 | None | code163 | Fabrication and supply of sheet steel enclosure out of 14 SWG CRCA Sheet duly powder coated the contro panel (Size of 2000 x1500x 450) is of compartment alized, All the components are duly wired and connected to Aluminum bus bar.-Supplying and fixing of 100 A 4 x 30 x 10 mm Alumunium Strips | m | 3445.35 | 3445.35 | 1.0 | False | None | None | False | None | False | 3445.35 | 0 |
2887482 | 94492 | None | code164 | Fabrication and supply of sheet steel enclosure out of 14 SWG CRCA Sheet duly powder coated the contro panel (Size of 2000 x1500x 450) is of compartment alized, All the components are duly wired and connected to Aluminum bus bar.-16 sqmm wire | m | 327.54 | 327.54 | 5.0 | False | None | None | False | None | False | 1637.7 | 0 |
2887483 | 94492 | None | code165 | Supplying and fixing of LED Panel Board indicating Lamp with required colour Suitable for 220 V AC 50 HZ | Each | 530.45 | 530.45 | 3.0 | False | None | None | False | None | False | 1591.35 | 0 |
2887484 | 94492 | None | code166 | Supplying of Multifunction Digital Meter | Each | 9594.45 | 9594.45 | 1.0 | False | None | None | False | None | False | 9594.45 | 0 |
2887485 | 94492 | None | code167 | Supplying and fixing of TPN ACCL 40A | Each | 10815.0 | 10815.0 | 1.0 | False | None | None | False | None | False | 10815.0 | 0 |
2887486 | 94492 | None | code168 | Supplying and fixing of 40 - 63 Amps TPN MCB | Each | 3180.64 | 3180.64 | 2.0 | False | None | None | False | None | False | 6361.28 | 0 |
2887487 | 94492 | None | code169 | Supplying and fixing of 50 x 50 x 6 mm Angle | m | 406.85 | 406.85 | 1.0 | False | None | None | False | None | False | 406.85 | 0 |
2887488 | 94492 | None | code170 | Supplying & running of GI/Cu. Strips for grounding connections using necessary fixing material as required…..-25 x 3 mm G.I strip. | m | 75.0 | 75.0 | 20.0 | False | None | None | False | None | False | 1500.0 | 0 |
2887489 | 94492 | None | code171 | Supplying & running of GI/Cu. Strips for grounding connections using necessary fixing material as required…..-600x600x3 GI Plate | Each | 760.0 | 760.0 | 2.0 | False | None | None | False | None | False | 1520.0 | 0 |
2887490 | 94492 | None | code172 | Supplying & running of GI/Cu. Strips for grounding connections using necessary fixing material as required…..-25 x 3 mm | m | 505.0 | 505.0 | 8.0 | False | None | None | False | None | False | 4040.0 | 0 |
2887491 | 94492 | None | code173 | Supplying & running of GI/Cu. Strips for grounding connections using necessary fixing material as required…..-600x600x3 Cu. Plate | Each | 6900.0 | 6900.0 | 1.0 | False | None | None | False | None | False | 6900.0 | 0 |
2887492 | 94492 | None | code174 | Supplying & running of GI/Cu. Strips for grounding connections using necessary fixing material as required….. 12 SWG GI wire | m | 14.0 | 14.0 | 78.0 | False | None | None | False | None | False | 1092.0 | 0 |
2887493 | 94492 | None | code175 | Supplying & running of GI/Cu. Strips for grounding connections using necessary fixing material as required….. 12 SWG | m | 58.0 | 58.0 | 39.0 | False | None | None | False | None | False | 2262.0 | 0 |
2887494 | 94492 | None | code176 | Supplying & running of GI/Cu. Strips for grounding connections using necessary fixing material as required….. 10 SWG | m | 68.0 | 68.0 | 39.0 | False | None | None | False | None | False | 2652.0 | 0 |
2887495 | 94492 | None | code177 | Supplying & running of GI/Cu. Strips for grounding connections using necessary fixing material as required….. 2C x 10sq.mm. Al. Alum. Cable | m | 95.0 | 95.0 | 20.0 | False | None | None | False | None | False | 1900.0 | 0 |
2887496 | 94492 | None | code178 | Supplying & running of GI/Cu. Strips for grounding connections using necessary fixing material as required….. 4C x 10sq.mm. Al. Alum. Cable | m | 130.0 | 130.0 | 23.0 | False | None | None | False | None | False | 2990.0 | 0 |
2887497 | 94492 | None | code179 | Supplying & running of GI/Cu. Strips for grounding connections using necessary fixing material as required….. 4C x 16sq.mm. Al. Alum. Cable | m | 150.0 | 150.0 | 23.0 | False | None | None | False | None | False | 3450.0 | 0 |
2887498 | 94492 | None | code180 | Supplying and fixing of 48 " Sweep 5 Star (1200 mm ) | Each | 2757.31 | 2757.31 | 22.0 | False | None | None | False | None | False | 60660.82 | 0 |
2887499 | 94492 | None | code181 | Supplying and fixing of 12" Exhausr fan 1400 rpm light duty exhaust fan | Each | 1536.76 | 1536.76 | 9.0 | False | None | None | False | None | False | 13830.84 | 0 |
2887500 | 94492 | None | code182 | Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. andfixing using invetred wood plugs in Case of RCC ceiling and RCC wall /stone structure or rawl plug incase of brick walls and cement plastering the damaged portion using heavy guage saddles in an intervel of 700 mm using NF Screws-25mm dia 2mm Thick | m | 81.37 | 81.37 | 156.0 | False | None | None | False | None | False | 12693.72 | 0 |
2887501 | 94492 | None | code183 | 4 Pair Telephone wire | m | 36.05 | 36.05 | 78.0 | False | None | None | False | None | False | 2811.9 | 0 |
2887502 | 94492 | None | code184 | Supplying & drawing UTP Cat 6 E Lan Cable | m | 39.14 | 39.14 | 254.0 | False | None | None | False | None | False | 9941.56 | 0 |
2887503 | 94492 | None | code185 | Supply & drawing of RG6 wire TV cable | m | 45.32 | 45.32 | 78.0 | False | None | None | False | None | False | 3534.96 | 0 |
2887504 | 94492 | None | code186 | Supplying & Fixing of Single I/0 | Each | 504.7 | 504.7 | 9.0 | False | None | None | False | None | False | 4542.3 | 0 |
2887505 | 94492 | None | code187 | Supplying & Fixing of Double I/O | Each | 566.5 | 566.5 | 1.0 | False | None | None | False | None | False | 566.5 | 0 |
2887506 | 94492 | None | code188 | Supplying & Fixing of T.V telephone Socket | Each | 160.68 | 160.68 | 11.0 | False | None | None | False | None | False | 1767.48 | 0 |
2887507 | 94492 | None | code189 | Supplying & Fixing of 12U with 800 mm depth | Each | 9100.05 | 9100.05 | 1.0 | False | None | None | False | None | False | 9100.05 | 0 |
2887508 | 94492 | None | code190 | Supplying & Fixing of power Strip | Each | 1500.71 | 1500.71 | 1.0 | False | None | None | False | None | False | 1500.71 | 0 |
2887509 | 94492 | None | code191 | 24 port 10 / 100 /1000 Switch | Each | 7637.45 | 7637.45 | 1.0 | False | None | None | False | None | False | 7637.45 | 0 |
2887510 | 94492 | None | code192 | Supplying & Fixing of 1 Mtr patch cable | Each | 230.72 | 230.72 | 10.0 | False | None | None | False | None | False | 2307.2 | 0 |
2887511 | 94492 | None | code193 | Supplying & Fixing of 2 Mtr patch cable | Each | 264.71 | 264.71 | 10.0 | False | None | None | False | None | False | 2647.1 | 0 |
2887512 | 94492 | None | code194 | Supplying & Fixing of 24 port 10 / 100 patch panel | Each | 8137.0 | 8137.0 | 1.0 | False | None | None | False | None | False | 8137.0 | 0 |
2887513 | 94492 | None | code195 | NON SR RATES-Providing supplying and fixing Hydraulic door closures with mounting heavy duty shuitable for flush door shutters including cost of materials,labour etc., complete as per specifications., | Nos | 1350.0 | 1350.0 | 2.0 | False | None | None | False | None | False | 2700.0 | 0 |
2887514 | 94492 | None | code196 | Supplying, installing, testing and commissioning approved make15 mm CP health faucet of approved make with necessary CP flexible hose 1.0m long nozzle, CP crutch,nozzle anguler stop cock with wall flange etc., complete.make: Jaguar,modle no. ALD-573 | Nos | 1307.0 | 1307.0 | 6.0 | False | None | None | False | None | False | 7842.0 | 0 |
2887515 | 94492 | None | code197 | Supplying, installing and testing Soap Dish including necessary fixing materials etc., complete. (Jal,Jaquar or equivalent) | Nos | 126.0 | 126.0 | 10.0 | False | None | None | False | None | False | 1260.0 | 0 |
2887516 | 94492 | None | code198 | Forming horizontal or vertical grooves on uniform size 10 mm wide and 7 mm deep at junction of wall and column / beam and finishing the grooves to elevation etc, including cost of materials , labour flor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incindental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge.per the instructions of the Engineer in charge. (All floors) | m | 31.0 | 31.0 | 650.0 | False | None | None | False | None | False | 20150.0 | 0 |
2887517 | 94492 | None | code199 | Providing and fixing sand cast iron soil waste single equal junction of required degree with access door 100x100x100mm, including cost of materials, labour, testing complete as per specifications. | Nos | 1044.96 | 1044.96 | 20.0 | False | None | None | False | None | False | 20899.2 | 0 |